Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “vacuum”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 865 records · Page 48

Impurities removal by laser blow-off from in-vacuum optical surfaces on RFX-mod experiment

An in situ window cleaning system by laser blow-off through optical fiber has been developed on the basis of a feasibility study previously presented. The beam generated by a Q-switched Nd:YAG laser is launched in a vacuum box into a high damage threshold optical fiber through a lens. The fiber output is focused on the impurities-coated surface of a vacuum window exposed to the plasma of the RFX-mod experiment, and it is remotely controlled with an xy motion system to scan the entire surface. We first investigate the energy density threshold necessary to ablate the deposited impurity substrate on removed dirty windows: above threshold, a single laser pulse recovers {approx}95% of the window transmission before its exposure to the plasma, while below it the efficiency of the cleaning process is too poor. The system so conceived was then used to clean the three collection windows of the Main Thomson scattering diagnostic on RFX-mod. We also present results obtained applying the same technique to the SiO-protected Al mirror used for the Z{sub eff} diagnostic: an energy threshold for efficient impurity removal without mirror damage is first identified, then ablation tests are executed and analyzed in terms of recovered reflectivity. The SIMS technique is used both with windows and mirror to study the composition of surfaces before and after the ablation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Quantum Decay of the 'False Vacuum' and Pair Creation of Soliton Domain Walls

Quantum decay of metastable states ('false vacua') has been proposed as a mechanism for bubble nucleation of new universes and phase transitions in the early universe. Experiments indicate the occurrence of false vacuum decay, within a region bounded by soliton domain walls that nucleate via quantum tunneling, in a highly anisotropic condensed matter system. This phenomenon provides a compelling example of false vacuum decay in the laboratory.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Megavolt range voltage measurement in vacuum through a short-circuited line

Method of voltage measurement at a vacuum load by means of homogeneous short-circuited vacuum-isolated line was considered. Prior to appearance of a measured high-voltage pulse, a magnetic field is formed in the line due to the bias current. Biasing provides fulfillment of magnetic electron isolation conditions and strong pressing of an electron layer down to the cathode already at the voltage wave front. As a result, a weak change of the ''hot'' line wave impedance is achieved during a pulse. Theoretical consideration and numerical simulation of the measuring line operation in the presence of bias current basing the applicability of the method was carried out. The method was used to determine the plasma-filled diode voltage at a megavolt voltage level. The absence of electron leakages at the voltage wave propagation of the amplitude {approx_equal}1 MV along the measuring line of the length 2.3 m with the wave impedance of 136 {Omega} and initial bias current of {approx_equal}6 kA was realized.

42 ENGINEERING↗

Fast Vacuum Decay into Quark Pairs in Strong Color Electric and Magnetic Fields

We study quark-pair creations in strong color electomagnetic fields. We point out that, for massless quarks, the vacuum persistency probability per unit space-time volume is zero, i.e., the quark-pair creation rate w is infinite, in general homogeneous color electromagnetic fields, while it is finite when the color magnetic field is absent. We find that the contribution from the lowest Landau level (LLL) dominates this phenomenon. With an effective theory of the LLL projection, we also discuss dynamics of the vacuum decay, taking into account the back reaction of pair creations.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Effect of residual gases in high vacuum on the energy-level alignment at noble metal/organic interfaces

The energy-level alignment at metal/organic interfaces has traditionally been studied using ultraviolet photoelectron spectroscopy (UPS) in ultra-high vacuum (UHV). However, since most devices are fabricated in high vacuum (HV), these studies do not accurately reflect the interfaces in real devices. We demonstrate, using UPS measurements of samples prepared in HV and UHV and current-voltage measurements of devices prepared in HV, that the small amounts of residual gases that are adsorbed on the surface of clean Cu, Ag, and Au (i.e., the noble metals) in HV can significantly alter the energy-level alignment at metal/organic interfaces.

36 MATERIALS SCIENCE↗

Gas Injection Apparatus for Vacuum Chamber

We present in this article a gas injection apparatus which comprises the gas injector and its electronic command for vacuum chamber applications. Some of these applications are thin-film deposition by a pulsed laser deposition (PLD) or a cathodic arc deposition (arc-PVD) and the plasma generation. The electronic part has been developed to adjust the flow of the gas inside the vacuum chamber by controlling both of the injector's opening time and the repetition frequency to allow a better gas flow. In this case, the system works either on a pulsed mode or a continuous mode for some applications. In addition, the repetition frequency can be synchronised with a pulsed laser by an external signal coming from the laser, which is considered as an advantage for users. Good results have been obtained using the apparatus and testing with Argon and Nitrogen gases.

36 MATERIALS SCIENCE↗

Surface enhanced Raman scattering of aged graphene: Effects of annealing in vacuum

In this paper, we report a simple method to recover the surface enhanced Raman scattering activity of aged graphene. The Raman signals of Rhodamine molecules absorbed on aged graphene are dramatically increased after vacuum annealing and comparable to those on fresh graphene. Atomic force microscopy measurements indicate that residues on aged graphene surface can efficiently be removed by vacuum annealing, which makes target molecule closely contact with graphene. We also find that the hole doping in graphene will facilitate charge transfer between graphene and molecule. These results confirm the strong Raman enhancement of target molecule absorbed on graphene is due to the charge transfer mechanism.

36 MATERIALS SCIENCE↗

Size-dependent emission efficiency and luminescence characteristics of YBO{sub 3}:Tb{sup 3+} nanocrystals under vacuum ultraviolet excitations

The luminous efficiency and lifetime of plasma display panels (PDPs) are directly related to the performance of phosphors used in PDPs, thus higher efficiency, higher stability against high temperature processes, and a long lifetime along with good color chromaticity against vacuum-ultraviolet radiation are major concerns in selecting suitable phosphors for PDPs. In the same pursuit, well crystallized pure hexagonal phase YBO{sub 3}:Tb{sup 3+} nanocrystals were prepared using co-precipitation method. The prepared YBO{sub 3}:Tb{sup 3+} nanocrystals showed bright green luminescence, color chromaticity (0.21, 0.61), and could be assigned to {sup 5}D{sub 4}{yields}{sup 7}F{sub j} transitions (j = 2-6) due to electric dipole-dipole interaction of Tb{sup 3+} ions. The vacuum ultraviolet photoluminescence spectroscopy of the prepared YBO{sub 3}:Tb{sup 3+} nanocrystals showed size dependent nonlinear luminescence enhancement with relatively shorter life time as compared to the commercial bulk YBO{sub 3}:Tb{sup 3+} phosphor. The quenching concentration of Tb{sup 3+} doping for ({sup 5}D{sub 4}{yields}{sup 7}F{sub 5}) transition was found significantly enhanced with the decrease in particle size suggesting it an ideal green phosphor for plasma display panels. The possible explanation for size-dependent emission efficiency and observed luminescence characteristics were proposed via charge transfer process and lowering of the structural symmetry.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Studies of photoconductivity and field effect transistor behavior in examining drift mobility, surface depletion, and transient effects in Si-doped GaN nanowires in vacuum and air

Variable intensity photoconductivity (PC) performed under vacuum at 325 nm was used to estimate drift mobility ({mu}) and density ({sigma}{sub s}) of negative surface charge for c-axis oriented Si-doped GaN nanowires (NWs). In this approach, we assumed that {sigma}{sub s} was responsible for the equilibrium surface band bending ( Empty-Set ) and surface depletion in the absence of illumination. The NWs were grown by molecular beam epitaxy to a length of approximately 10 {mu}m and exhibited negligible taper. The free carrier concentration (N) was separately measured using Raman scattering which yielded N = (2.5 {+-} 0.3) Multiplication-Sign 10{sup 17} cm{sup -3} for the growth batch studied under 325 nm excitation. Saturation of the PC was interpreted as a flatband condition whereby Empty-Set was eliminated via the injection of photogenerated holes. Measurements of dark and saturated photocurrents, N, NW dimensions, and dimensional uncertainties, were used as input to a temperature-dependent cylindrical Poisson equation based model, yielding {sigma}{sub s} in the range of (3.5 to 7.5) Multiplication-Sign 10{sup 11} cm{sup -2} and {mu} in the range of (850 to 2100) cm{sup 2}/(V s) across the (75 to 194) nm span of individual NW diameters examined. Data illustrating the spectral dependence and polarization dependence of the PC are also presented. Back-gating these devices, and devices from other growth batches, as field effect transistors (FETs) was found to not be a reliable means to estimate transport parameters (e.g., {mu} and {sigma}{sub s}) due to long-term current drift. The current drift was ascribed to screening of the FET back gate by injected positive charge. We describe how these gate charging effects can be exploited as a means to hasten the otherwise long recovery time of NW devices used as photoconductive detectors. Additionally, we present data illustrating comparative drift effects under vacuum, room air, and dry air for both back-gated NW FETs and top-gated NW MESFETs.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Design of an ultrahigh vacuum transfer mechanism to interconnect an oxide molecular beam epitaxy growth chamber and an x-ray photoemission spectroscopy analysis system

We designed a mechanism and the accompanying sample holders to transfer between a VEECO 930 oxide molecular beam epitaxy (MBE) and a PHI Versa Probe X-ray photoemission spectroscopy (XPS) chamber within a multiple station growth, processing, and analysis system through ultrahigh vacuum (UHV). The mechanism consists of four parts: (1) a platen compatible with the MBE growth stage, (2) a platen compatible with the XPS analysis stage, (3) a sample coupon that is transferred between the two platens, and (4) the accompanying UHV transfer line. The mechanism offers a robust design that enables transfer back and forth between the growth chamber and the analysis chamber, and yet is flexible enough to allow transfer between standard sample holders for thin film growth and masked sample holders for making electrical contacts and Schottky junctions, all without breaking vacuum. We used this mechanism to transfer a barium strontium titanate thin film into the XPS analysis chamber and performed XPS measurements before and after exposing the sample to the air. After air exposure, a thin overlayer of carbon was found to form and a significant shift ({approx}1 eV) in the core level binding energies was observed.

36 MATERIALS SCIENCE↗

Surface photoconductivity of organosilicate glass dielectrics induced by vacuum-ultraviolet radiation

The temporary increase in the electrical surface conductivity of low-k organosilicate glass (SiCOH) during exposure to vacuum-ultraviolet radiation (VUV) is investigated. To measure the photoconductivity, patterned “comb structures” are deposited on dielectric films and exposed to synchrotron radiation in the range of 8–25 eV, which is in the energy range of most plasma vacuum-ultraviolet radiation. The change in photo surface conductivity induced by VUV radiation may be beneficial in limiting charging damage of dielectrics by depleting the plasma-deposited charge.

36 MATERIALS SCIENCE↗

Compact ultrahigh vacuum sample environments for x-ray nanobeam diffraction and imaging

X-ray nanobeams present the opportunity to obtain structural insight in materials with small volumes or nanoscale heterogeneity. The effective spatial resolution of the information derived from nanobeam techniques depends on the stability and precision with which the relative position of the x-ray optics and sample can be controlled. Nanobeam techniques include diffraction, imaging, and coherent scattering, with applications throughout materials science and condensed matter physics. Sample positioning is a significant mechanical challenge for x-ray instrumentation providing vacuum or controlled gas environments at elevated temperatures. Such environments often have masses that are too large for nanopositioners capable of the required positional accuracy of the order of a small fraction of the x-ray spot size. Similarly, the need to place x-ray optics as close as 1 cm to the sample places a constraint on the overall size of the sample environment. We illustrate a solution to the mechanical challenge in which compact ion-pumped ultrahigh vacuum chambers with masses of 1–2 kg are integrated with nanopositioners. The overall size of the environment is sufficiently small to allow their use with zone-plate focusing optics. We describe the design of sample environments for elevated-temperature nanobeam diffraction experiments demonstrate in situ diffraction, reflectivity, and scanning nanobeam imaging of the ripening of Au crystallites on Si substrates.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ellipsometry with polarisation analysis at cryogenic temperatures inside a vacuum chamber

In this paper we describe a new variant of null ellipsometry to determine thicknesses and optical properties of thin films on a substrate at cryogenic temperatures. In the PCSA arrangement of ellipsometry the polarizer and the compensator are placed before the substrate and the analyzer after it. Usually, in the null ellipsometry the polarizer and the analyzer are rotated to find the searched minimum in intensity. In our variant we rotate the polarizer and the compensator instead, both being placed in the incoming beam before the substrate. Therefore the polarisation analysis of the reflected beam can be realized by an analyzer at fixed orientation. We developed this method for investigations of thin cryogenic films inside a vacuum chamber where the analyzer and detector had to be placed inside the cold shield at a temperature of T≈ 90 K close to the substrate. All other optical components were installed at the incoming beam line outside the vacuum chamber, including all components which need to be rotated during the measurements. Our null ellipsometry variant has been tested with condensed krypton films on a highly oriented pyrolytic graphite substrate (HOPG) at a temperature of T≈ 25 K. We show that it is possible to determine the indices of refraction of condensed krypton and of the HOPG substrate as well as thickness of krypton films with reasonable accuracy.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multifunctional ultra-high vacuum apparatus for studies of the interactions of chemical warfare agents on complex surfaces

A fundamental understanding of the surface chemistry of chemical warfare agents is needed to fully predict the interaction of these toxic molecules with militarily relevant materials, catalysts, and environmental surfaces. For example, rules for predicting the surface chemistry of agents can be applied to the creation of next generation decontaminants, reactive coatings, and protective materials for the warfighter. Here, we describe a multifunctional ultra-high vacuum instrument for conducting comprehensive studies of the adsorption, desorption, and surface chemistry of chemical warfare agents on model and militarily relevant surfaces. The system applies reflection-absorption infrared spectroscopy, x-ray photoelectron spectroscopy, and mass spectrometry to study adsorption and surface reactions of chemical warfare agents. Several novel components have been developed to address the unique safety and sample exposure challenges that accompany the research of these toxic, often very low vapor pressure, compounds. While results of vacuum-based surface science techniques may not necessarily translate directly to environmental processes, learning about the fundamental chemistry will begin to inform scientists about the critical aspects that impact real-world applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Results from sudden loss of vacuum on scaled superconducting radio frequency cryomodule experiment

Superconducting radio frequency (SRF) cavities for particle accelerators are at risk of failure due to sudden loss of vacuum (SLV) adjacent to liquid helium (LHe) spaces. To better understand this failure mode and its associated risks an experiment is designed to test the longitudinal effects of SLV within the beam tube of a scaled SRF cryomodule that has considerable length relative to beam tube cross section. The scaled cryomodule consists of six individual SRF cavities each roughly 350 mm long, initially cooled to 2 K by a superfluid helium bath and a beam tube pumped to vacuum. A fast-acting solenoid valve is used to simulate SLV on the beam tube, from which point it takes over 3 s for the beam tube pressure to equalize with atmosphere, and 30 s for the helium space to reach the relief pressure of 4 bara. A SLV longitudinal effect in the beam tube is evident in both pressure and temperature data, but interestingly the temperatures responds more quickly to SLV than do the pressures. It takes 500 ms (roughly 100 ms per cavity) for the far end of the 2 m long beam tube to respond to a pressure increase compared to 300 ms for temperature (approximately 50 ms per cavity). The paper expands upon these and other results to better understand the longitudinal effect for SRF cryomodules due to SLV.

43 PARTICLE ACCELERATORS↗

Tunable vacuum ultraviolet laser based spectrometer for angle resolved photoemission spectroscopy

We have developed an angle-resolved photoemission spectrometer with tunable vacuum ultraviolet laser as a photon source. The photon source is based on the fourth harmonic generation of a near IR beam from a Ti:sapphire laser pumped by a CW green laser and tunable between 5.3 eV and 7 eV. The most important part of the set-up is a compact, vacuum enclosed fourth harmonic generator based on potassium beryllium fluoroborate crystals, grown hydrothermally in the US. This source can deliver a photon flux of over 10{sup 14} photon/s. We demonstrate that this energy range is sufficient to measure the k{sub z} dispersion in an iron arsenic high temperature superconductor, which was previously only possible at synchrotron facilities.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A passive measurement of dissociated atom densities in atmospheric pressure air discharge plasmas using vacuum ultraviolet self-absorption spectroscopy

We demonstrate a method for determining the dissociation degree of atmospheric pressure air discharges by measuring the self-absorption characteristics of vacuum ultraviolet radiation from O and N atoms in the plasma. The atom densities are determined by modeling the amount of radiation trapping present in the discharge, without the use of typical optical absorption diagnostic techniques which require external sources of probing radiation into the experiment. For an 8.0 mm spark discharge between needle electrodes at atmospheric pressure, typical peak O atom densities of 8.5 × 10{sup 17} cm{sup −3} and peak N atom densities of 9.9 × 10{sup 17} cm{sup −3} are observed within the first ∼1.0 mm of plasma near the anode tip by analyzing the OI and NI transitions in the 130.0–132.0 nm band of the vacuum ultraviolet spectrum.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

On the mechanism of operation of a cathode spot cell in a vacuum arc

The erosive structures formed on a tungsten cathode as a result of the motion of the cathode spot of a vacuum arc over the cathode surface have been examined. It has been found that the average mass of a cathode microprotrusion having the shape of a solidified jet is approximately equal to the mass of ions removed from the cathode within the lifetime of a cathode spot cell carrying a current of several amperes. The time of formation of a new liquid-metal jet under the action of the reactive force of the plasma ejected by the cathode spot is about 10 ns, which is comparable to the lifetime of a cell. The growth rate of a liquid-metal jet is ∼10{sup 4} cm/s. The geometric shape and size of a solidified jet are such that a new explosive emission center (spot cell) can be initiated within several nanoseconds during the interaction of the jet with the dense cathode plasma. This is the underlying mechanism of the self-sustained operation of a vacuum arc.

36 MATERIALS SCIENCE↗