Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “use cases”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 865 records · Page 48

Examining the Role of IMU Health Characterization and Monitoring in UAS Safety

Inertial measurement units (IMUs) can be vital for vehicle attitude and position estimation in unmanned aerial vehicles (UAVs). Degradation in these units could result in incorrect position estimates that are utilized in vehicle control, trajectory prediction, and other critical systems; however, the modes and effects of degradation in these IMUs are not well understood. In order to quantify the risk posed by degradation in these sensors, a study was conducted on the types of IMUs prevalent in the commercial market, their known failure modes, and the applicability to health monitoring methods for risk reduction and increased safety in an increasingly autonomous airspace. First, use cases and failure modes of the various types and reliability of commercially available IMUs were reviewed, and knowledge gaps and issues in the field were identified. Noting that inexpensive and lightweight MEMS (Microelectromechanical Systems) IMUs are some of the most commonly used but least reliable sensors in sUAS (small Unmanned Aerial Systems), five inexpensive MEMS IMUs were chosen for a performance evaluation study, selected from the Pixhawk autopilot systems, hobby sUAS, and prior NASA experimental studies. For each of these IMUs, a 10-minute bias test and a 12-hour drift test were performed for the accelerometers in a benchtop setting, using a BeagleBone Black for data collection. Using these results, the sensors’ performance is compared to their reported specifications, and the utility of implementing diagnostic methods for MEMS IMUs for research and commercial applications is evaluated. The paper concludes with a planned study for the evaluation of vibration-induced degradation for the selected sensors.

IMUs↗

dCache: Inter-disciplinary storage system

The dCache project provides open-source software deployed internationally to satisfy ever more demanding storage requirements. Its multifaceted approach provides an integrated way of supporting different use-cases with the same storage, from high throughput data ingest, data sharing over wide area networks, efficient access from HPC clusters and long term data persistence on a tertiary storage. Though it was originally developed for the HEP experiments, today it is used by various scientific communities, including astrophysics, biomed, life science, which have their specific requirements. In this paper we describe some of the new requirements as well as demonstrate how dCache developers are addressing them.

Mkrtchyan, Tigran↗

Wrapper for the optimization of cross-section generation in OpenMC

The "Wrapper for the optimization of cross-section generation in OpenMC" is Python-based software that runs the open-source Monte Carlo code OpenMC (https://docs.openmc.org/en/stable/ ) to generate cross-sections for any reactor geometry. The wrapper then optimizes those cross sections. The optimization aims to choose an energy group structure and a scattering representation that maximize accuracy with respect to continuous-energy results while avoiding significant computational expense. It then outputs these cross-sections in an ISOXML format readable by the Idaho National Lab code suite MOOSE (Olin William Calvin, Mark D DeHart, “Architecture for the Performance of Nuclear Fuel Depletion Calculations”, Idaho National Laboratory report, November 2019). The expected use-cases of this software include: -finding the best group structure and scattering representation for a specific reactor -testing the appropriateness of energy group structures for different reactor types -comparing energy group structures and scattering representations to each other -generating cross sections for use in deterministic codes, including ones found in the MOOSE suite The example reactor geometry included in this release is a generic reactor design, not based on any reactor in existence or in development. It was fabricated for the sole purpose of being a “testbed-geometry” upon which to develop this tool. Since the tool is designed to be generic, the nature of the test geometry is not very important, however, it is valuable to include as an example for users who are unfamiliar with developing reactor geometries for OpenMC.

Kreher, Miriam↗

Developing a Framework for Valuation of Grid Services

The electric system is rapidly evolving and growing, raising new questions about how to define and value grid services delivered by a diverse set of resources, including customer-owned assets. This report advances a service–parameter–value framework that links what a grid service does to why it matters, and how its benefits are evidenced. We build upon prior efforts (Bender et al. 2021) and extend them to include value categories (reliability, resilience, cost & access, and security) with primary and secondary tiers, service-specific value streams that explain how benefits materialize, and metrics that make valuation traceable and comparable. We apply the framework to the six core grid services defined in (Kolln et al. 2023): Frequency Response, Regulation, Reserves, Energy, Voltage Management, and Blackstart and demonstrate it on three use cases to highlight the adaptability of these value streams. Further, we outline how the framework integrates with existing tools such as asset optimization, hosting capacity and cost-benefit analysis, and propose a path to portable qualifications and consistent stacking rules for use in tariffs and filings. Finally, we identify future pathways for research and application research needs to support standardization and decision-ready comparisons across services, assets, and architectures.

24 POWER TRANSMISSION AND DISTRIBUTION↗

SSBRP Communication & Data System Development using the Unified Modeling Language (UML)

The Unified Modeling Language (UML) is the standard method for specifying, visualizing, and documenting the artifacts of an object-oriented system under development. UML is the unification of the object-oriented methods developed by Grady Booch and James Rumbaugh, and of the Use Case Model developed by Ivar Jacobson. This paper discusses the application of UML by the Communications and Data Systems (CDS) team to model the ground control and command of the Space Station Biological Research Project (SSBRP) User Operations Facility (UOF). UML is used to define the context of the system, the logical static structure, the life history of objects, and the interactions among objects.

Windrem, May↗

Three-Dimensional Grid Visualization for Planning Activities: A Dubai Case Study

National Laboratory of the Rockies (NLR), in collaboration with the Dubai Electricity and Water Authority (DEWA) and Infra-X, has undertaken the Energy Visualization Analysis Project. The aim of this project is to enhance analytical and 3D visualization capabilities for distribution network planning and renewable energy integration. As modern grid continues to evolve with large-scale solar PV deployment and emerging distributed energy resources (DERs), the ability to effectively analyze, visualize, and communicate complex grid behaviors has become increasingly critical. The project focuses on developing empirical use cases based on real distribution feeder data and engineering workflows, ensuring the outcomes are directly aligned with operational environment. Through time-series power flow simulations and nodal hosting capacity analysis, the study quantifies the impacts of high PV penetration on voltage and thermal limits within representative 11 kV feeders. These analyses identify specific nodes and conditions where DER integration challenges arise. Furthermore, a Battery Energy Storage System (BESS) optimization algorithm was applied to determine the optimal size and placement of storage systems that can mitigate network constraints and enhance hosting capacity. The comparative results between base-case and BESS-augmented scenarios clearly demonstrate improvements in network stability and load management efficiency. In parallel, the NLR team developed an immersive 3D visualization framework, enabling interactive exploration of grid simulations using commodity head-mounted display (HMD) systems. This framework transforms conventional 2D simulation data into spatially intuitive visual environments - allowing engineers to analyze feeder conditions, PV hosting potential, and BESS effects in real time. This report represents the first foundational phase in establishing a visualization-driven analytical ecosystem. It provides a methodological foundation for data integration, visualization architecture, and simulation-based decision support, paving the way for large-scale adoption of immersive visualization across DEWA's Smart Grid Initiative, R&D activities, and future network resilience studies.

24 POWER TRANSMISSION AND DISTRIBUTION↗

dCache: The Storage System of Choice for Data-Intensive Applications

The ever-increasing volumes of data produced by modern scientific facilities like EuXFEL and LHC put significant stress on data management infrastructure operated by laboratories and research centers. The challenges to be addressed span the entire data life cycle, from ingest and efficient data analysis to long-term preservation, typically involving large tape libraries. dCache, a storage system developed in collaboration between the Deutsches Elektronen-Synchrotron (DESY), Fermi National Accelerator Laboratory, and Nordic e-Infrastructure Collaboration (NeIC), is designed to manage a large number of disk servers and to facilitate transparent data migration to and from archival storage. Its multifaceted approach offers a unified method to support a variety of scientific use cases with the same storage infrastructure, including high-throughput data ingest, data sharing over wide area networks, efficient access from HPC clusters, and long-term data preservation on tertiary storage. Initially developed for high energy physics (HEP) experiments, dCache is now used by various scientific communities, including astrophysics, biomedical research, and life sciences, each having specific requirements. This paper presents architecture, deployment strategies, performance and scalability enhancements, and recent advancements in dCache addressing the needs of scientific communities. Finally, we touch on the development and release process, ensuring the software’s high quality.

DCache↗

Field Validation of Thermoelectric Generation System at Holcim Cement Plant in Alpena, Michigan

Executive Summary Project Background The Industrial Technology Validation (ITV) program aims to identify and demonstrate the performance of new, emerging, and underutilized energy-saving technologies in the industrial sector to help inform decisions to help accelerate their commercialization and deployment, as well as to help make industries more competitive. This ITV demonstration evaluated a thermoelectric generation (TEG) technology at a cement plant, aiming to reduce energy demand in the cement industry. A median cement plant consumes 5.73 million British thermal units per ton of clinker production (resulting in 0.838 metric tons of carbon dioxide [CO₂] emissions per ton of clinker) (Boyd and Zhang 2011, EPA 2021), equivalent to approximately 6.9 trillion British thermal units (TBtu) per year in energy consumption at a cement plant producing 3,300 tons of clinker per day.¹ Collaborating with Holcim, Advanced Thermovoltaic Systems (ATS) developed and deployed a pilot-scale thermoelectric power system to efficiently capture and convert waste heat to electricity. The system leverages the Seebeck effect to convert temperature differences on two sides of semiconductor cartridges into electrical power (ScienceDirect, n.d.). This generation is realized with minimal moving parts compared to existing waste-heat-to-generation solutions and allows capture from heat sources with temperatures as low as 150°C. This project aimed to validate a scalable solution applicable for capturing medium-temperature waste heat, including ambient losses from other high-temperature processes, and high-temperature sources less suitable for other waste-heat-to-power solutions. By recovering this otherwise wasted heat, this project intends to validate improvements to overall process efficiency through reduction in purchased electricity, thereby reducing operational costs while enhancing resiliency and competitiveness. Description and Scope This study evaluated the performance of a TEG system from ATS as a solution to convert waste heat into useful power at a Holcim cement plant in Alpena, Michigan. This plant is a fully integrated cement plant that has been operating since 1907. The facility operates continuously (24/7/365) with approximately 250 employees and five long dry kilns, yielding a total production capacity of 7,852 tons of cement per day (EPA 2023). Currently, the Alpena plant uses waste heat boilers to convert waste heat from the exhaust of each kiln into steam, which drives steam turbine generators. The ATS TEG is being evaluated for its potential to supplement the steam turbines by capturing the remaining lower grade heat. This technology is also being considered for other Holcim plants where steam turbines are not a viable option. ATS installed a pilot-scale TEG unit with an array of 582 individual thermoelectric semiconductor cartridges, of which 573 were operational. The cartridges are sandwiched between 48 hot plates and 49 cold plates. Each cartridge is designed to generate 20 watts (W) of gross power at a hot-side temperature of 240°C and cold-side temperature of 20°C. As such, the total gross generation capacity of the installed system is 11.5 kilowatts (kW) at design conditions. The system configuration for the evaluation was designed to prioritize convenience of installation and minimize disruption to production at the site, while ensuring that the heat required can be obtained for evaluating the TEG system at various operational conditions. To accomplish this, a portion of the steam supplied to Alpena’s steam turbine generation system was diverted to be used as the heat source for the TEG system, while water was supplied to the cold side of the system from nearby Lake Huron. This configuration was designed for the evaluation of the pilot-scale system to assess the performance at different conditions. A commercial-scale system will likely vary from the pilot system depending on typical configurations, including both scale and application. Future commercial applications of the ATS system would involve integrating the system into the exhaust from kiln preheaters, clinker coolers, or radiant heat capture from kiln shells for the heat source. For the cold source, a range of cooling solutions can be considered, including a mechanical cooling system, depending on the location and the application. To increase the generation capacity for commercial applications, the technology provider is working toward developing a commercial-scale TEG system, which would combine multiple TEG units (each similar in design to the pilot system) together. The scope of this evaluation includes the pilot-scale TEG system and all impacted equipment including pumps, controllers, and power handling equipment. Study Objectives The evaluation's goal was to assess the potential of the ATS TEG system to generate useful electrical power by capturing waste heat from cement production kilns. The objectives of this study are to evaluate and verify the following claims made by ATS regarding the pilot-scale system installed at the Holcim Alpena plant. The following design parameters and claims are also outlined in Table ES- 1 and Table ES- 2: • Gross Power: The thermoelectric system converts heat into power to create gross power, the total measured power generated by the system. The 573 active cartridge pilot-scale system is expected to generate 11.5 kW of gross power at the designed hot-side temperature of 240°C and cold-side temperature of 20°C. Power production is dependent on the temperature difference between the heat source (ultimately from the waste heat) and cold temperature supply source. • Net Power: The net power is the total usable power provided to the site by the TEG system after deducting parasitic power loads from the gross generated power. Supplementary equipment is required to operate the TEG system including pumps, controllers, and, in certain anticipated applications, mechanical cooling, which introduce parasitic loads to system operation. After deducting the parasitic loads from the gross power generation, ATS anticipates achieving a net power generation of 7.5 kW from the pilot-scale system. • Thermal Efficiency: The thermal efficiency is the percent of the total heat transferred to the TEG system that is converted to gross power. Historically, TEGs have a thermal efficiency of 2%–5% (DOE 2008). Prior industrial-scale TEG systems, such as the E1 TEG offered by Alphabet Energy, operated at an efficiency of 2.5% (Lamonica, 2014). ATS anticipates achieving an average efficiency of 4.8% or higher in converting heat energy to usable electricity. • Cartridge Performance: The TEG system comprises 573 active individual semiconductor cartridges, each of which generates a portion of the total power. Cartridge optimization and selection is an important design consideration for potential future TEG system design performance. Therefore, understanding the distribution of gross power and efficiency within the pilot system is vital to understanding what is achievable. At a design hot-side temperature of 240°C and cold-side temperature of 20°C, ATS anticipates a cartridge performance of 20 W of gross power per cartridge at an efficiency of 4.8% per cartridge. In addition to evaluating the claimed performance of the TEG pilot-scale unit, the study estimated the potential annual impacts of a scaled-up commercial system used to capture kiln waste heat over annual operations. The evaluation estimated the gross and net annual electric generation achievable by capturing heat from the two proposed tap-in points: the kiln exhaust and the clinker cooler exhaust; see Section 2.1 for details. Two use cases were examined: • Holcim Alpena: The Holcim Alpena site consists of long dry kilns with superheater boilers, which differs from the rest of Holcim’s cement plant portfolio and results in lower waste heat temperatures. The study estimates gross and net annual generation using the superheater boiler exhaust and clinker cooler exhaust, based on 2023 operational data. • Typical Installation: Common cement plants have preheater kilns with higher exhaust temperatures than Holcim Alpena across a range of production rates. The study estimates gross and net annual generation using the preheater exhaust and clinker cooler exhaust, with a sensitivity analysis to account for the typical range of preheater exhaust temperatures, clinker cooler exhaust temperatures, and clinker production rates. Methodology The evaluation methodology followed a measurement and verification (M&V) strategy based on the International Performance Measurement and Verification Protocol Option B through comprehensive measurements and analyses of the affected systems. Evaluation data was collected from March 9 to March 11, 2024, the test period of the pilot TEG system. During the test period, in coordination with the ITV team, the ATS team adjusted system operations to capture the range of variability expected for each of the variables pertinent to performance of the system. The methodology consisted of two parts: evaluating the performance of the pilot unit's TEG system and estimating the annual TEG impact in terms of gross and net power based on a given waste heat profile. First, the evaluation of the thermoelectric generation performance of the pilot unit relative to the claims was performed by analyzing the collected test data. Gross power of the pilot TEG system was directly measured. Net power was determined by deducting the measured parasitic power from the gross power. The gross power generation was compared to heat transferred to the system by the working fluid (which was heated by steam generated from the kiln waste heat) to calculate the thermal efficiency achieved by the system. Performance of individual semiconductor cartridges within the pilot array was also assessed in terms of measured gross cartridge power and calculated cartridge thermal efficiency. The second part of the evaluation estimated the annual TEG impacts in terms of gross power and net power (calculated from the difference between gross power and parasitic power). This analysis comprised development of mathematical regression models for gross power and parasitic power, with assessment of each model’s goodness-of-fit characteristics to ensure satisfaction of statistical requirements. The models predicted the gross power generation, the parasitic load based on the temperature difference between the hot working fluid and the cold-side fluid (cold water from Lake Huron) entering the system, the volumetric flow rate of the cold-side fluid at the inlet, and the volumetric flow rate of the hot working fluid at the inlet. The annual impact analysis considered a theoretical commercial-scale system sized to capture the available waste heat at a cement plant, consisting of linked pilot-scale units that receive heat from a theoretical gas-to-working-fluid heat exchanger. To estimate annual impacts at the Alpena plant, the gross power and parasitic power regression models were applied to the arrays in the theoretical commercial-scale system. The heat supplied to the unit was calculated based on the kiln run time, annual production, kiln exhaust waste heat, and clinker cooler waste heat derived from 2023 Holcim Alpena kiln operational data. Net power impacts were calculated by deducting the resulting parasitic power from the estimated gross power. Inputs for the model were generated from a combination of hourly data, assumed design considerations for TEG system scale-up from the pilot-scale unit, and assumptions regarding TEG system operations. This analysis was then used as the basis for estimating annual impacts of typical TEG installation at cement plants, by applying sensitivity analyses to key kiln operational characteristics including kiln preheater exhaust temperatures, cooler clinker exhaust temperatures, and plant daily production rates across a range of expected values. Project Results/Findings Table ES- 2 and Table ES- 2 provide a summary of the operating conditions and evaluation results compared to the stated claims from the technology provider. Key takeaways include: • Gross Power: The peak gross power achieved during the testing period was 10.0 kW, compared to the 11.5 kW expected for 573 active cartridges. The claimed gross power was associated with a target hot side of 240°C; however, the system only received a maximum hot-side mean plate temperature of 212°C during the testing period. • Net Power: The pilot-scale unit exceeded the claims for net power, achieving a peak of 7.7 kW net compared to a claim of 7.5 kW. One factor contributing to the higher achieved net power is the relatively high water pressure available through Lake Huron. The pilot TEG system did not require cold-side pumps during the test, whereas most installations would. This reduced the parasitic loads on the system, ultimately contributing to higher net power relative to the gross power. • Thermal Efficiency: The pilot-scale unit outperformed the claimed efficiency, achieving a peak system efficiency of 5.0% thermal efficiency compared to the stated 4.8%. • Cartridge Performance: To compare cartridge performance against claims, the study focused on the third day of testing, which aimed for conditions closest to the design specifications, with a hot side of 240°C and cold-side exit temperature of 6.4°–30°C. On this day, the mean gross power observed in the cartridges within the TEG array was 18.1 W/cartridge, and the peak performance was 34.7 W/cartridge. The estimated mean cartridge efficiency was 5.2%, and the estimated efficiency at peak gross cartridge power was 10%. The regression models developed for gross power generation and parasitic loads were used to estimate the generation impact for given heat input to the TEG from the working fluid (captured from the waste heat) and from the cold loop (Lake Huron) on an hourly basis for a year of operation. Based on this analysis, installation of a commercial-scale TEG system at the Holcim cement plant in Alpena, Michigan, with a waste heat exchanger of 0.85 effectiveness, would generate up to 391 kW of net power, translating to between 920,000 and 1,800,000 kilowatt-hours (kWh) in net electricity per year. Based on typical grid emissions for Alpena, this would avoid estimated net emissions by 752 metric tons of CO₂ annually.² The sensitivity analysis estimated that typical TEG system installations at cement plants could generate an average of 56–1,040 kW of net power, or between 488,000 and 9,110,000 kWh of net energy. This generation potential is most significantly affected by plant production rates and also influenced by preheater and clinker cooler exhaust temperatures. Applying the national average emission rate, typical commercial-scale installations at Holcim plants are projected to avoid between 182 and 3,401 metric tons of CO₂ annually per site. Table ES- 3 shows a summary of the estimated annual impacts.³ While parasitic loads are significant and vary by application, this analysis assumed the use of heating loop pumps and access to Lake Huron as a cold sink. This setup assumed no need for cooling loop pumps due to the available water pressure at the test site. Applications that require cooling towers or additional equipment are likely to experience higher parasitic loads. Therefore, the study’s estimates are most applicable to scenarios with similar parasitic load configurations—namely, access to a high-pressure cold sink. Applicability to other locations may be limited, as differing conditions could necessitate additional pumps and cooling systems, potentially impacting performance significantly.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Cybersecurity Threat Profile for a Connected Lighting System

In this paper we analyze a threat profile performed on a fault-detection use case for streetlights. A threat profile establishes security requirements, justifies security measures, yields actionable controls, and effectively communicates risk to stakeholders. This effort provides critical information for making threat-based decisions to increase security at a reasonable cost, and can effectively be used by development teams, software architects, and managers to make cybersecurity a part of their ongoing culture of awareness, training, and prevention. This leads to more secure systems and better-understood security. On-premise, cloud, and hybrid architectures with different authentication mechanisms were modeled and later categorized using the Microsoft STRIDE framework. An analysis of the recommended controls for each threat was performed to determine which controls could and should be put in place by manufacturers or third-party suppliers, and which controls need to be left up the end-user to implement.

97 MATHEMATICS AND COMPUTING↗

A Cybersecurity Threat Profile for a Connected Lighting System

In anticipation of improved energy performance and cost savings, cities and building owners are increasingly considering “smart lighting initiatives” that aim to convert their collection of simple luminaires (i.e., lighting fixtures) into an intelligent connected lighting system (CLS) capable of remotely monitoring energy consumption and fault conditions, and possibly implementing adaptive lighting schemes. The U.S. Department of Energy (DOE) has set an national goal of tripling the energy efficiency and demand flexibility of the buildings sector by 2030, relative to 2020 levels 1. It is forecast that connected lighting systems can contribute to that goal by delivering 125 TWh of annual energy savings by 2035 2, equivalent to the annual output of 50 typical (500 MW) power plants. However, these energy savings and the DOE goal are put at significant risk if connected technologies are not adopted due to real or perceived cybersecurity concerns. Connected IoT devices such as these have historically been rife with vulnerabilities which sometimes put security considerations secondary to functionality and operability. What are the cybersecurity threats that will impact these systems, as formerly banal luminaires transition into intelligent connected devices that collect information about themselves, their surrounding environment, and possibly us? In this paper we analyze a threat profile performed on a fault-detection use case for streetlights. A threat profile establishes security requirements, justifies security measures, yields actionable controls, and effectively communicates risk to stakeholders. This effort provides critical information for making threat-based decisions to increase security at a reasonable cost, and can effectively be used by development teams, software architects, and managers to make cybersecurity a part of their ongoing culture of awareness, training, and prevention. This leads to more secure systems and better-understood security. On-premise, cloud, and hybrid architectures with different authentication mechanisms were modeled and later categorized using the Microsoft STRIDE framework. An analysis of the recommended controls for each threat was performed to determine which controls could and should be put in place by manufacturers or third-party suppliers, and which controls need to be left up the end-user to implement. Fifty-seven threats were identified. Among our key findings: (1) 65% (37/57) of the threats did not involve the luminaires, but rather the other components needed to communicate with and manage them; (2) 63% (36/57) of the threats could have been mitigated through manufacturer-implemented defensive techniques or “controls”; and (3) 23% (13/57) of the threats were dependent on the network configuration. Recommendations based on the results of this work are made to key stakeholder groups. Notably, lighting technology developers are advised to address all threats that can be reasonably controlled with baked-in technology solutions (e.g., encryption or authentication controls), and employ some form of secure supply chain management and tracking where other parts (e.g., sensors, microprocessors) of a luminaire must also be built and manufactured with the proper security controls in place. Developers should also review threats involving assets not developed in-house to understand how connectivity with other devices will affect their product during system operation and determine if a compensating control for a defense-in-depth strategy will be needed. Finally, those interested in deploying CLS should compare the differences between cloud and on-premise models to determine which is more suitable for their needs and the abilities of their security team.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Smart Contract Architectures and Templates for Blockchain-based Energy Markets (V.1.0)

Within the field of Transactive Energy Systems (TES), there is an active need for tools that can support and accelerate the development of these new grid solutions. Among the many tools available, blockchain stands out as a viable instrument that can help researchers develop decentralized, autonomous, and tamper-resistant grid applications. In this work, we explore the use of smart contracts (SCs), a subset of blockchain technology, and analyze their applicability to facilitating the implementation of TES solutions. In particular, we focus on presenting areas of opportunity and potential drawbacks, along with use cases that can benefit from this technology building upon previous research developed by Pacific Northwest National Laboratory and other research organizations. This work builds upon the fundamentals of TES and smart contract technology to develop a series of software templates that can be used by industry to build TES-oriented grid solutions. These templates are intended to be platform agnostic and take into consideration the unique properties of SCs and distributed ledger storage mechanisms to ensure actual code implementations remain aware of the limitations of the technology. The proposed templates have the potential to enable software architects to mix and match components to satisfy their application requirements, thereby reducing the number of resources required to implement blockchain-based solutions. These templates are divided into two main components—data and behavioral models. The data models are intended to help software engineers represent the underlying grid objects along with their properties in a ledger-based storage system. The behavioral models are used to describe the processes and actions that actors within a system must perform to achieve a given outcome such as registering an asset, placing a bid, and performing bid clearances. These two components are documented in a Unified Modeling Language (UML) format and are intended for use in SC-based implementations, with special behavioral considerations to account for the asynchronous properties of the underlying ledger and the typical execution model of smart contracts. Finally, future research ideas and potential extensions to this work are discussed. In particular, known limitations and potential improvements of the developed product are identified and expected to be addressed in future revisions of the template model.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Composable optimization and control toolkit for scientific applications

Applications of Artificial Intelligence (AI) and Machine Learning (ML) can improve the computational efficiency and scientific research output. In order to improve interoperability and reuse of AI/ML software, a composable approach is required. This talk presents a composable approach for scientific workflow development that allows seamless integration of various modules developed by independent researchers. These practices will reduce redundant software development by allowing re-use of workflow modules across projects, teams, departments and facilities. We will present three use cases that follow the composable approach namely, Scientific Optimization and Control Toolkit (SOCT), SciDAC QuantOm workflow, and JLab Nuclear Physics experimental workflows. This talk will dive deeper into SOCT and present the details of the composable code development for optimization and control algorithms using reinforcement learning.

Rajput, Kishansingh↗

A multi-scale time-series dataset with benchmark for machine learning in decarbonized energy grids

The electric grid is a key enabling infrastructure for the ambitious transition towards carbon neutrality as we grapple with climate change. With deepening penetration of renewable resources, the reliable operation of the electric grid becomes increasingly challenging. In this paper, we present PSML, a first-of-its-kind open-access multi-scale time-series dataset, to aid in the development of data-driven machine learning (ML)-based approaches towards reliable operation of future electric grids. The dataset is synthesized from a joint transmission and distribution electric grid to capture the increasingly important interactions and uncertainties of the grid dynamics, containing power, voltage and current measurements over multiple spatio-temporal scales. Using PSML, we provide state-of-the-art ML benchmarks on three challenging use cases of critical importance to achieve: (i) early detection, accurate classification and localization of dynamic disturbances; (ii) robust hierarchical forecasting of load and renewable energy; and (iii) realistic synthetic generation of physical-law-constrained measurements. We envision that this dataset will provide use-inspired ML research in safety-critical systems, while simultaneously enabling ML researchers to contribute towards decarbonization of energy sectors.

54 ENVIRONMENTAL SCIENCES↗

Cyclic creep analysis from elastic finite-element solutions

A uniaxial approach was developed for calculating cyclic creep and stress relaxation at the critical location of a structure subjected to cyclic thermomechanical loading. This approach was incorporated into a simplified analytical procedure for predicting the stress-strain history at a crack initiation site for life prediction purposes. An elastic finite-element solution for the problem was used as input for the simplified procedure. The creep analysis includes a self-adaptive time incrementing scheme. Cumulative creep is the sum of the initial creep, the recovery from the stress relaxation and the incremental creep. The simplified analysis was exercised for four cases involving a benchmark notched plate problem. Comparisons were made with elastic-plastic-creep solutions for these cases using the MARC nonlinear finite-element computer code.

Kaufman, A.↗

Transition of a Three-Dimensional Unsteady Viscous Flow Analysis from a Research Environment to the Design Environment

The advent of advanced computer architectures and parallel computing have led to a revolutionary change in the design process for turbomachinery components. Two- and three-dimensional steady-state computational flow procedures are now routinely used in the early stages of design. Unsteady flow analyses, however, are just beginning to be incorporated into design systems. This paper outlines the transition of a three-dimensional unsteady viscous flow analysis from the research environment into the design environment. The test case used to demonstrate the analysis is the full turbine system (high-pressure turbine, inter-turbine duct and low-pressure turbine) from an advanced turboprop engine.

Dorney, Suzanne↗

Irradiation-enhanced diffusion and diffusion-limited creep in U 3 Si 2

U 3 Si 2 is an advanced fuel candidate due to its relatively high fissile density and attractive thermal properties. Compared to standard UO 2 fuel, there are significant data gaps for the thermophysical and thermomechanical properties of U 3 Si 2 . Point defect concentrations and mobilities under irradiation govern a number of important fuel performance properties, such as creep and fission gas release. In this work, we utilized density functional theory (DFT) data to inform a cluster dynamics framework to predict point defect concentrations in U 3 Si 2 under irradiation. Molecular dynamics (MD) simulations were used to examine the contribution of atomic mixing during ballistic cascades to diffusion, as well as the diffusivity of U and Si at grain boundaries. These atomic scale models for diffusivity were then used to inform a creep model based on bulk (Nabarro-Herring) and grain boundary (Coble) diffusional creep, and climb-limited dislocation creep. The model compares well against available experimental data and has been implemented in the BISON fuel performance code. Finally, a demonstration case using simple power profiles has been carried out, showing that negligible creep occurs due to the low temperatures experienced by U 3 Si 2 in-reactor, a consequence of its high thermal conductivity.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Conflicts of Greens’ in Renewable Energy Landscapes: Case Studies and a Planning Framework

Reducing greenhouse gas emissions (GHG) through renewable energy deployment is a goal for many cities and nations to mitigate the effects of a rapidly changing climate while securing energy needs. Given national and state level policies on green energy to achieve GHG reduction targets, localities are considering utility-scale renewable energy (USRE) facilities on remote lands, rural areas, oceans, coastal waters and large rivers to meet the energy needs for urban residents and industries. Although these USRE facilities generate much “greener” electricity than fossil fuel power plants, locating them can pose conflicts with wildlife, including endangered, threatened and/or special status species, and the habitats that support wildlife populations (Brunette et al., 2013; Gasparatos et al. 2016; Mulvaney 2017), which lead to a “Conflict of Greens” (Ko et al., 2011). In addition to ecological impacts, conflicts over social and cultural resources in local communities lead to concerns over environmental justice, in this context “energy justice,” where negative environmental, social, and economic impacts of energy projects fall more heavily upon marginalized, vulnerable, or indigenous communities. The Pacific Rim region is a center of major and growing economies, and it has become a battlefield for competing “green” objectives. In addition to progressive renewable energy goals, such as in California, Hawaii, and Taiwan, countries around the Pacific Rim have the majority of the growth in manufacturing of wind and solar energy devices and also some of the highest levels of renewables deployment with China, India, and the US leading the way in wind and solar installations. Developing renewable energy source in the ocean such as offshore wind, tidal, and wave energy, are beginning to add to this mix. Given this challenge, the APRU SCL energy working group provides six case studies that address questions about the “Conflict of Greens” across the Pacific Rim including South Korea, Taiwan, and the United States (California, Hawaii, and Massachusetts). The literature review highlights the emerging ecological, social, and economic aspects of conflicts over siting renewables on the landscape. Using case studies, we examine the trial and errors in least-conflict spatial planning, data collection and analysis, public participation in decision-making, mitigation, social planning for energy transitions, and multi-scalar approaches. Lastly, we recommend interdisciplinary policy, planning, and design actions for sustainable energy landscapes across the Pacific Rim and beyond.

green versus green, renewable energy↗

Computational fluid dynamics drag prediction: Results from the Viscous Transonic Airfoil Workshop

Results from the Viscous Transonic Airfoil Workshop held in January 1987, are compared with each other and with experimental data. Test cases used include attached and separated transonic flows for the NACA 0012 airfoil. A total of 23 sets of numerical results from 15 different author groups are included. The numerical methods used vary widely and include: 16 Navier-Stokes methods, 2 Euler/boundary-layer methods, and 5 potential/boundary-layer methods. The results indicate a high degree of sophistication among the numerical methods with generally good agreement between the various computed and experimental results for attached or moderately separated cases. The agreement for cases with larger separation is only fair and suggests additional work is required in this area.

Holst, Terry L.↗