Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “units”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 865 records · Page 48

Urban stream deserts: Mapping a legacy of urbanization in the United States

Protecting, as well as restoring, natural resources within the urban landscape has environmental and economic importance, especially as the global population continues to shift towards urban areas. One extreme legacy of rapid development and urbanization is stream burial. Riverless urban areas are mapped in 11 Megaregions within the United States, with additional focus on the Great Lakes, using a semi-automated, geoprocessing workflow completed within ArcMap10.2. Combining U.S. Census Bureau Urban Areas (UAs), Impervious Surface Coverage (ISC) from the 2011 National Land Cover Dataset (NLCD), and National Hydrography Dataset (NHD) flowlines, allowed the delineation of urban stream deserts (UrbSDs), or watershed areas where stream channels have likely been buried or removed. Approximately 6.2% of the area of UAs (or 11,490 km 2 ) within the 11 Megaregions are UrbSD, and they are most prevalent in major cities in the North California and Great Lakes Megaregions. Specifically, 537 UrbSD exist within the Great Lakes Megaregion, with Detroit (MI) and Chicago (IL) comprising some of the largest UrbSDs in the United States. Regardless of Megaregion, UrbSDs represent the most intensely urbanized components of the urban environment, as UrbSDs have higher population densities, impervious surface coverage and developed land uses than adjacent urban areas. UrbSD are unique, but poorly understood, components of the urban ecosystem that highlights the consequences of sacrificing longterm environmental sustainability (e.g., ecosystem services) for short-term economic growth (rapid development).

54 ENVIRONMENTAL SCIENCES↗

Evaluation of flammable volume in the case of a catastrophic leak of R-32 from a rooftop unit

With the effort to use alternative refrigerants with lower global warming potential (GWP), the majority of these alternative refrigerants are classified as slightly flammable. Here in this paper we report on the numerical evaluation of a catastrophic leak scenario of R-32 refrigerant from a 3-ton roof top air conditioning unit (RTU) which serves a 12.2 × 9.14 × 2.4 m room. A full rupture of a 6.35 mm (¼ inch) pipe downstream of the evaporator coil is simulated. Two separate cases with refrigerant releases of 1.81 kg and 3.62 kg charge have been studied. The two charges are released in 10.2 and 20.4 s, respectively, just after the end of a unit cooling cycle. The flammable volume inside the room existed only for about 40 s with a maximum flammable volume inside the room of 1.12% of the total room volume for the 3.62 kg charge case.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Home charging for all: Techno-economic and life cycle assessment of multi-unit dwelling electric vehicle charging hubs

Ubiquitous electric vehicle adoption can drastically reduce greenhouse gas emissions (GHG) but will require equitable home charging infrastructure for all residences. Unlike single-family homes, Multi-Unit Dwellings (MUD) currently lack market share and access to nearby charging infrastructure partly due to expensive capital costs for reluctant residential property-owners. Further, this work evaluates the levelized cost of charging (LCOC) for Battery Electric Vehicles (BEVs) at MUD community charging hubs through a techno-economic analysis (TEA) that leverages real-world charging data and costs. Three different MUD charging types are investigated for a baseline and optimistic case: 1.9-kW Level 1 (L1), 6.6-kW Level 2 (L2), and 50-kW Direct Current Fast Charging (DCFC) stations under three different ownership models: resident, utility, and private company. Results demonstrate L1 and L2 chargers to be less expensive than the gasoline equivalent across the United States. Further, utility and private company ownership models, which avoid initial costs for residential property owners, result in a large LCOC premium for L1 and moderate LCOC premium for L2 relative to the resident ownership model. In contrast, DCFC is shown to be expensive for baseline scenarios but economical for optimistic scenarios especially under private company ownership. This work also performs a cradle to grave (C2G) life cycle assessment (LCA) of an average passenger BEV and gasoline conventional vehicle (CV) using yearly (grid mix & vehicle parameters), hourly (grid mix), and state-level (grid mix) resolution. Results show BEVs to have lower GHG emissions (-86% to-10%) than gasoline CVs in the contiguous U.S. Next, the system boundary of the TEA is extended to the total cost of ownership (TCO) of BEVs. The TCO is then coupled with the C2G GHG emissions to calculate the cost of GHG emissions reduction. Ultimately, the cost of GHG emissions reduction from MUD BEVs relative to gasoline CVs is shown to be negative for every scenario except baseline DCFC, meaning MUD BEV charging infrastructure can be a cost-effective endeavor to reduce GHG emissions.

33 ADVANCED PROPULSION SYSTEMS↗

Multiscale petrophysical characterization and flow unit classification of the Minnelusa eolian sandstones

Integration of petrophysical and geological information is critical to simulation of subsurface carbon storage (GCS). In this sense, two depositional facies were identified from the core description and well-log interpretation, namely massive (MS) and cross-bedded (CB) facies groups. Additionally, pore-scale characteristics were studied by a combination of techniques, e.g. Nuclear Magnetic Resonance (NMR) and mercury intrusion capillary pressure (MICP). Scanning electron microscope (SEM) and petrographic analyses show that the pore structure is dominantly controlled by the depositional environment and dolomite cementation. NMR-T 2 distributions of MS and CB facies show triple and quadruple modes, respectively. In addition, MICP of high- and low-permeability MS facies samples, and their CB facies group mixtures were collected. The MS sample pore-throat size distribution is uni-modal, while the triple-modal characteristic of the mixtures indicates heterogeneous pore structures at the sub-core scale for CB facies. The reliably estimates of porosity and permeability for both facies groups via NMR techniques and the MLR (Multiple Linear Regression) approach demonstrate the applicability of these techniques to eolian sandstone. Moreover, irreducible water saturation via the T 2 -cutoff method correlates strongly with T 2LM instead of porosity. Finally, the rock quality index and flow zone indicator were calculated based on Combinable Magnetic Resonance (CMR) log interpretations. This provides direct connection to properties measured in the well. Four flow units were classified for both facies groups. Finally, results show that better reservoir quality with significant heterogeneities is observed in the CB facies. This study highlights the importance integrating multiscale petrophysical properties including facies, pore architecture and diagenesis analysis with core- to log-scale property characterization. The results herein validate our reservoir characterization and flow unit classification in eolian reservoirs.

58 GEOSCIENCES↗

In Situ Data Infrastructure for Scientific Unit Testing Platform

Testing is a significant software development process for the management of software systems and scientific code. However, as the complexity of scientific codes increases, extra checks are needed to monitor impacts to dependent models and to verify system constraints. The software complexity also impedes the efforts of module developers and software engineers to rapidly develop and extend their code. Recently, we have developed an automatic methodology and prototype platform to facilitate scientific verification of individual functions within complex scientific codes. With this system, the scientific module builders are able to track variables conveniently in one module or track variables’ changes among different modules. In this paper, we present a procedure for automatic unit testing generation. For the interest of a general audience of this conference, we are emphasizing the technical details of integrating the In Situ data infrastructure into our platform. At the end of this paper, we have included an implementation of unit testing for the ACME Land Model (ALM) to demonstrate the usefulness and correctness of the platform. We have also used single- and multipoint checks to demonstrate the efficient variable tracking capability of this platform.

97 MATHEMATICS AND COMPUTING↗

Uncertainty Analysis of Simulations of the Turn-of-the-Century Drought in the Western United States

Here, we perform the first uncertainty quantification analysis of the turn-of-the-century drought in the western United States using a large perturbed-parameter ensemble of the Community Atmosphere Model version 4.0 (CAM4). We develop several metrics to characterize the aridity bias, spatial extent, and tropical forcing of the drought and use statistical models to ascertain that the modeled drought was mainly sensitive to CAM4 parameters related to deep convection and clouds. Deep convection parameters account for over half the variance across the drought metrics. We employ observed estimates of these drought metrics to infer probability distributions of the model parameters that lead to a better agreement with observations, thereby providing guidance on how to improve the simulation of drought in CAM4. We find that in some cases, the suggested parameter values that improve the simulation of one drought characteristic would degrade the simulation of another, suggesting that there is a complex relationship between the model parameters and drought in the western United States. We also demonstrate reductions in the uncertainty of the drought metrics of up to 30% by constraining with observations of all metrics. Additionally, we demonstrate for the first time that improvements to the simulation of the spatial extent of the turn-of-the-century drought also lead to improvements in the spatial extent of the Australian Millennium drought, suggesting that physics of drought as encoded by the model parameters may be generalizable.

58 GEOSCIENCES↗

Regional Snow Parameters Estimation for Large-Domain Hydrological Applications in the Western United States

In snow-dominated regions, a critical source of uncertainty in hydrologic prediction and forecasting is the magnitude and distribution of snow water equivalent (SWE). With ensemble simulations, we demonstrate that SWE variability across the mountain ranges of the western United States (represented by 246 Snow Telemetry stations) can largely be captured at the daily time scale by a simple mass and energy-balance snow model with four physically reasonable parameters—three snow albedo parameters and one snow temperature threshold for precipitation partitioning. The model skill is lower in the maritime Pacific Northwest where SWE variability is more sensitive to errors associated with simulated energy balance (e.g., downward radiation fluxes) and the temperature-only precipitation partitioning approach. Poor model skill in high-altitude, windy locations in the Northern Rockies can be attributed to precipitation undercatch and underrepresented wind processes. For the purpose of large-domain hydrologic applications, regional snow parameters were developed for eight ecoregions characterized by a distinct hydroclimatic regime across the western United States. Results indicate that regionally coherent snow parameterizations are able to capture daily variations in SWE at most Snow Telemetry stations, suggesting that areas with a similar hydroclimate share a similar snow regime. While the three albedo parameters show limited spatial variability across all regions, the regional snow temperature threshold (Ts) shows marked spatial variation correlated with relative humidity; the Ts values increase from 0.2 °C in the higher-humidity Pacific Northwest to 4.0 °C in the colder, lower-humidity Rocky Mountains.

58 GEOSCIENCES↗

Decision support for United States—Canada energy integration is impaired by fragmentary environmental and electricity system modeling capacity

The renewable energy transition is leading to increased electricity trade between the United States and Canada, with Canadian hydropower providing firm lower-carbon power and buffering variability of wind and solar generation in the U.S. However, long-term power purchase agreements and transborder transmission projects are controversial, with two of four proposed transmission lines between Quebec, Canada and the northeast U.S. cancelled since 2018. Here, we argue that controversies are exacerbated by a lack of open-source data and tools to understand tradeoffs of new hydropower generation and transmission infrastructure in comparison to alternatives. This gap includes impacts that incremental transmission and generation projects have on the economics of the entire system, for example, how new transmission projects affect exports to existing markets or incentivize new generation. We identify priority areas for data synthesis and model development, such as integrating linked hydropower and hydrologic interactions in energy system models and openly releasing (by utilities) or back-calculating (by researchers) hydropower generation and operational parameters. Publicly available environmental (e.g. streamflow, precipitation) and techno-economic (e.g. costs, reservoir size,) data can be used to parameterize freely usable and extensible models. Existing models have been calibrated with operational data from Canadian utilities that are not publicly available, limiting the range of scientific and commercial questions these tools have been used to answer and the range of parties that have been involved. Studies conducted using highly resolved, national-scale public data exist in other countries, notably, the United States, and demonstrate how greater transparency and extensibility can drive industry action. Improved data availability in Canada could facilitate approaches that (1) increase participation in decarbonization planning by a broader range of actors; (2) allow independent characterizations of environmental, health, and economic outcomes of interest to the public; and (3) identify decarbonization pathways consistent with community values.

13 HYDRO ENERGY↗

XUV double-pulses with femtosecond to 650 ps separation from a multilayer-mirror-based split-and-delay unit at FLASH

Extreme ultraviolet (XUV) and X-ray free-electron lasers enable new scientific opportunities. Their ultra-intense coherent femtosecond pulses give unprecedented access to the structure of undepositable nanoscale objects and to transient states of highly excited matter. In order to probe the ultrafast complex light-induced dynamics on the relevant time scales, the multi-purpose end-station CAMP at the free-electron laser FLASH has been complemented by the novel multilayer-mirror-based split-and-delay unit DESC (DElay Stage for CAMP) for time-resolved experiments. XUV double-pulses with delays adjustable from zero femtoseconds up to 650 picoseconds are generated by reflecting under near-normal incidence, exceeding the time range accessible with existing XUV split-and-delay units. Procedures to establish temporal and spatial overlap of the two pulses in CAMP are presented, with emphasis on the optimization of the spatial overlap at long time-delays via time-dependent features, for example in ion spectra of atomic clusters.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Application of sulfur SAD to small crystals with a large asymmetric unit and anomalous substructure

The application of sulfur single-wavelength anomalous dispersion (S-SAD) to determine the crystal structures of macromolecules can be challenging if the asymmetric unit is large, the crystals are small, the size of the anomalously scattering sulfur structure is large and the resolution at which the anomalous signals can be accurately measured is modest. Here, as a study of such a case, approaches to the SAD phasing of orthorhombic Ric-8A crystals are described. The structure of Ric-8A was published with only a brief description of the phasing process [Zeng et al. (2019), Structure , 27 , 1137–1141]. Here, alternative approaches to determining the 40-atom sulfur substructure of the 103 kDa Ric-8A dimer that composes the asymmetric unit are explored. At the data-collection wavelength of 1.77 Å measured at the Frontier micro-focusing Macromolecular Crystallography (FMX) beamline at National Synchrotron Light Source II, the sulfur anomalous signal strength, |Δ ano |/σΔ ano ( d ′′/sig), approaches 1.4 at 3.4 Å resolution. The highly redundant, 11 000 000-reflection data set measured from 18 crystals was segmented into isomorphous clusters using BLEND in the CCP 4 program suite. Data sets within clusters or sets of clusters were scaled and merged using AIMLESS from CCP 4 or, alternatively, the phenix.scale_and_merge tool from the Phenix suite. The latter proved to be the more effective in extracting anomalous signals. The HySS tool in Phenix , SHELXC / D and PRASA as implemented in the CRANK 2 program suite were each employed to determine the sulfur substructure. All of these approaches were effective, although HySS , as a component of the phenix.autosol tool, required data from all crystals to find the positions of the sulfur atoms. Critical contributors in this case study to successful phase determination by SAD included (i) the high-flux FMX beamline, featuring helical-mode data collection and a helium-filled beam path, (ii) as recognized by many authors, a very highly redundant, multiple-crystal data set and (iii) the inclusion within that data set of data from crystals that were scanned over large ω ranges, yielding highly isomorphous and highly redundant intensity measurements.

59 BASIC BIOLOGICAL SCIENCES↗

Developing Frequency Stability Constraint for Unit Commitment Problem Considering High Penetration of Renewables

As zero-carbon electricity systems become the trend of future grid, the system inertia provided by conventional synchronous generators (SGs) keeps decreasing. The resultant lower system inertia will inevitably cause frequency stability problem, especially in the first few seconds following disturbance. To tackle this challenge, this paper proposes a frequency stability constraint for power systems unit commitment problem by considering the fast frequency responses (FFRs) from inverter-based resources (IBRs). Our developed frequency stability constraint is grounded on an analytical frequency nadir estimation framework that considers both SG and IBR dynamics. The accuracy of our frequency nadir estimation framework is validated by most severe N-1 contingency simulation result in a real island system. Then, the adaptive inertia frequency stability constraint is derived by performing sensitivity analysis with our frequency nadir estimation framework. Finally, we demonstrate the effectiveness of our developed frequency stability constraint with one year day-ahead unit commitment results of the island system.

fast frequency response↗

Harmonics and Stability Evaluation of Converter-Interfaced Combined Heat and Power Units

Grid integration of medium-sized combined heat and power (CHP) units is challenging due to strict grid codes and conventional generators lack of control flexibility to meet these grid codes. Adding a two-stage ac-dc-ac power electronics interface between the generator and the utility grid will accelerate the interconnection process of CHP units. For the dc-ac stage, a voltage source converter (VSC) has been widely used as a grid-tied inverter because of its fast control and low total harmonics distortion (THD). In this paper, several topologies of generator-side rectifiers for ac-dc power conversion are explored and analyzed. The harmonics impact of various rectifiers on the CHP generator are evaluated. The overall cost of the electrical system, when using various types of rectifiers, is assessed and the VSC back-to-back converter interface configuration is found to be optimal. The overall system stability is also examined using small-signal impedance analysis to assess potential instability issues at the system level.

CHP, Harmonics, Generator Rectifier Unit, DC Imped↗

Strengthened MILP formulation for certain gas turbine unit commitment problems

In this study, we derive a strengthened MILP formulation for certain gas turbine unit commitment problems, in which the ramping rates are no smaller than the minimum generation amounts. This type of gas turbines can usually start-up faster and have a larger ramping rate, as compared to the traditional coal-fired power plants. Recently, the number of this type of gas turbines increases significantly due to affordable gas prices and their scheduling flexibilities to accommodate intermittent renewable energy generation. In this study, several new families of strong valid inequalities are developed to help reduce the computational time to solve these types of problems. Meanwhile, the validity and facet-defining proofs are provided for certain inequalities. Finally, numerical experiments on a modified IEEE 118-bus system and the power system data based on recent studies verify the effectiveness of applying our formulation to model and solve this type of gas turbine unit commitment problems, including reducing the computational time to obtain an optimal solution or obtaining a much smaller optimality gap, as compared to the default CPLEX, when the time limit is reached with no optimal solutions obtained.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Unit Commitment With Continuous-Time Generation and Ramping Trajectory Models

There is increasing evidence of shortage of ramping resources in the real-time operation of power systems. To explain and remedy this problem systematically, we take a novel look at the way the day-ahead unit commitment (UC) problem represents the information about load, generation and ramping constraints. We specifically investigate the approximation error made in mapping of the original problem, that would decide the continuous-time generation and ramping trajectories of the committed generating units, onto the discrete-time problem that is solved in practice. We first show that current practice amounts to approximating the trajectories with linear splines. We then offer a different representation through cubic splines that provides physically feasible schedules and increases the accuracy of the continuous-time generation and ramping trajectories by capturing sub-hourly variations and ramping of load in the day-ahead power system operation. The corresponding day-ahead UC model is formulated as an instance of mixed-integer linear programming (MILP), with the same number of binary variables as the traditional UC formulation. Numerical simulation over real load data from the California ISO demonstrate that the proposed UC model reduces the total day-ahead and real-time operation cost, and the number of events of ramping scarcity in the real-time operations.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Exploiting Identical Generators in Unit Commitment

Here, we present sufficient conditions under which thermal generators can be aggregated in mixed-integer linear programming (MILP) formulations of the unit commitment (UC) problem, while maintaining feasibility and optimality for the original disaggregated problem. Aggregating thermal generators with identical characteristics (e.g., minimum/maximum power output, minimum up/down-time, and cost curves) into a single unit reduces redundancy in the search space induced by both exact symmetry (permutations of generator schedules) and certain classes of mutually non-dominated solutions. We study the impact of aggregation on two large-scale UC instances, one from the academic literature and another based on real-world operator data. Our computational tests demonstrate that when present, identical generators can negatively affect the performance of modern MILP solvers on UC formulations. Further, we show that our reformation of the UC MILP through aggregation is an effective method for mitigating this source of computational difficulty.

97 MATHEMATICS AND COMPUTING↗

Global Solution Strategies for the Network-Constrained Unit Commitment Problem with AC Transmission Constraints

Here, we propose a novel global solution algorithm for the network-constrained unit commitment problem that incorporates a nonlinear alternating current (AC) model of the transmission network, which is a nonconvex mixed-integer nonlinear programming (MINLP) problem. Our algorithm is based on the multi-tree global optimization methodology, which iterates between a mixed-integer lower-bounding problem and a nonlinear upper-bounding problem. We exploit the mathematical structure of the unit commitment problem with AC power flow constraints (UC-AC) and leverage second-order cone relaxations, piecewise outer approximations, and optimization-based bounds tightening to guarantee a globally optimal solution at convergence. Numerical results on four benchmark problems illustrate the effectiveness of our algorithm, both in terms of convergence rate and solution quality.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Encoding Frequency Constraints in Preventive Unit Commitment Using Deep Learning With Region-of-Interest Active Sampling

With the increasing penetration of renewable energy, frequency response and its security are of significant concerns for reliable power system operations. Frequency-constrained unit commitment (FCUC) is proposed to address this challenge. Despite existing efforts in modeling frequency characteristics in unit commitment (UC), current strategies can only handle oversimplified low-order frequency response models and do not consider wide-range operating conditions. This paper presents a generic data-driven framework for FCUC under high renewable penetration. Here, deep neural networks (DNNs) are trained to predict the frequency response using real data or high-fidelity simulation data. Next, the DNN is reformulated as a set of mixed-integer linear constraints to be incorporated into the ordinary UC formulation. In the data generation phase, all possible power injections are considered, and a region-of-interest active sampling is proposed to include power injection samples with frequency nadirs closer to the UFLC threshold, which enhances the accuracy of frequency constraints in FCUC. The proposed FCUC is investigated on the IEEE 39-bus system. Then, a full-order dynamic model simulation using PSS/E verifies the effectiveness of FCUC in frequency-secure generator commitments.

42 ENGINEERING↗

The Ramping Polytope and Cut Generation for the Unit Commitment Problem

We present a perfect formulation for a single generator in the unit commitment problem, inspired by the dynamic programming approach taken by Frangioni and Gentile. This generator can have characteristics such as ramp-up/ramp-down constraints, time-dependent start-up costs, and start-up/shut-down limits. To develop this perfect formulation, we extend the result of Balas on unions of polyhedra to present a framework allowing for flexible combinations of polyhedra using indicator variables. Here, we use this perfect formulation to create a cut-generating linear program, similar in spirit to lift-and-project cuts, and demonstrate computational efficacy of these cuts in a utility-scale unit commitment problem.

97 MATHEMATICS AND COMPUTING↗