Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “treatment”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 865 records · Page 48

Mesofluidic Inline Separation for Produced Water Treatment: CRADA 537 [Abstract only]

The mesofluidic inline separation developed by PNNL represents an opportunity to remove a key barrier in the treatment of produced water: suspended solids that clog downstream operations to remove dissolved solids. The US alone produces over a trillion gallons of produced water each year, most of which is reinjected as a waste product. The impact from treating and reusing even a fraction of this water is immense as aquifers in the Midwest and elsewhere drying.

54 ENVIRONMENTAL SCIENCES↗

Record of Treatment for Concrete Preservation Work at TA-6-0037 Concrete Bowl, TA-08 Gun Site, TA-16-0518 Stem Wall, and TA-18 Battleship Bunkers (Historic Buildings Report)

This completion report documents concrete preservation work that occurred in Fiscal Years 2019 and 2020. Work took place at four sites (Technical Areas [TAs] -06, -08, -16, and -18) that hold Manhattan Project–era significance. Seven buildings and structures were included in the project scope, with concentrated assessments and treatment plans accomplished before the start of preservation activities. The attended buildings and structures represent eligible or included Manhattan Project National Historical Park resources. The stabilization of original fabric and the retention of integrity and significance remained paramount throughout all phases of this project.

42 ENGINEERING↗

Hanford Waste Treatment Plant LAB Facility Stack Effluent Monitoring: Sampling Probe Location Qualification Evaluation

The Waste Treatment Plant laboratory (LAB) facility stack monitor locations were qualified using scale model stacks to mitigate the risk of identifying that sampling locations do not meet the qualification criteria on the full-scale stack. As required by the American National Standards Institute/Health Physics Society (ANSI/HPS) N13.1-1999 standard, the scale model and its sampling location were geometrically similar to the actual stack and the Reynolds numbers for both the actual and model stacks were >10,000. An additional criterion is that the product of the hydraulic diameter and mean velocity (DV) of the full-scale stack must be between 1/6 DV and 6 DV of the scale model stack tests. Verification tests of the LAB stacks were performed at normal operating conditions. The minimum 1/6 DV value, along with the maximum 6 DV value from the scale model testing determines the range of conditions for which the full-scale stack may be operated and remain in compliance with the stack verification criterion. Based on these DV values, the corresponding stack flow rates for each of the LAB stacks are 625 to 47,237 scfm for LB-C2, 1,704 to 103,131 scfm for LB-S1, and 467 to 18,088 scfm for LB-S2. The remaining criteria for the stack verification to be considered valid involve the flow angle and velocity uniformity results. First, the flow angle at the full-scale stack must be =20°. Second, the velocity uniformity at the full-scale stack must be =20% coefficient of variance (COV). Finally, the velocity uniformity results for the actual and scale model stack tests must agree within 5% COV. These criteria were met through the full-scale stack tests at the LAB facility. Flow angle results were primarily less than 10 degrees, except for the LB-C2 Fan A results, which were an average of 17.6 degrees; all flow angle results were within the =20° criterion. The velocity uniformity results for each test condition averaged between 1.5 and 3.5% COV, which were all within the range of the target %COV values from the scale model tests. Based on these stack verification test results, the three LAB filtered exhaust stack sampling locations meet the qualification criteria provided in the ANSI/HPS N13.1-1999 standard for all fan operating configurations. This includes single-fan as well as dual-fan operations for LB-C2, each of the dual-fan operating conditions for LB-S1, and each single-fan operating condition for LB-S2. Further changes to the system configuration or operating conditions that are outside the bounds described in this report may require additional tests or analyses to determine compliance with the standard.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Hanford Waste Treatment Plant Low Activity Waste Facility Stack Effluent Monitoring - Sampling Probe Location Qualification Evaluation

The Hanford Tank Waste Treatment and Immobilization Plant low activity waste (LAW) facility stack monitor locations were qualified using scale model stacks to mitigate the risk of identifying that sampling locations do not meet the qualification criteria on the full-scale stack. As required by the American National Standards Institute/Health Physics Society (ANSI/HPS) N13.1-1999 standard, the scale model and its sampling location were geometrically similar to the actual stack and the Reynolds numbers for both the actual and model stacks were >10,000. An additional criterion is that the product of the hydraulic diameter and mean velocity (DV) of the full-scale stack must be between 1/6 DV and 6 DV of the scale model stack tests. Verification tests of the LAW stacks were performed at normal operating conditions. The minimum 1/6 DV value, along with the maximum 6 DV value from the scale model testing determines the range of conditions for which the full-scale stack may be operated and remain in compliance with the stack verification criterion. Based on these DV values, the corresponding stack flow rates for each of the LAW stacks are 815–55,758 scfm for LV-S1, 980–112,078 scfm for LV-S2, 264–22,901 scfm for LV-S3, and 981–79,832 scfm for LV-C2. The remaining criteria for the stack verification to be considered valid involve the flow angle and velocity uniformity results. First, the flow angle at the full-scale stack must be =20°. Second, the velocity uniformity at the full-scale stack must be =20% coefficient of variance (COV). Finally, the velocity uniformity results for the actual and scale model stack tests must agree within 5% COV. These criteria were met through the full-scale stack tests at the LAW facility. Flow angle results were primarily less than 10°, except for one LV-S2 Fan A result, which was 13.2°; all flow angle results were within the =20° criterion. The velocity uniformity results for each test condition ranged between 1.5 COV and 9.2% COV, which were all within the range of the target % COV values from the scale model tests. Based on these stack verification test results, the four LAW filtered exhaust stack sampling locations meet the qualification criteria provided in the ANSI/HPS N13.1-1999 standard for all fan operating configurations. This includes single-fan operating conditions for LV-S1 and LV-S2, dual-fan operations for LV-S3 at both the continuous air monitor and record sampler locations, and both the single-fan as well as the dual-fan operations for LV-C2. Further changes to the system configuration or operating conditions that are outside the bounds described in this report may require additional tests or analyses to determine compliance with the standard.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Hanford Waste Treatment Plant Effluent Management Facility Stack Effluent Monitoring: Sampling Probe Location Qualification Evaluation

The Hanford Tank Waste Treatment and Immobilization Plant Effluent Management facility (EMF) stack monitor location was qualified using the LV-S1 scale model stack as a baseline, augmented by the LB-S1 and LV-S2 scale model stacks to address the Direct Feed Low Activity Waste Effluent Management Facility Vessel Vent Process (DVP) injection into the main Active Confinement Ventilation (ACV) system duct. As required by the American National Standards Institute/Health Physics Society (ANSI/HPS) N13.1-1999 standard, the scale models and its sampling locations were geometrically similar to the actual stack and the Reynolds numbers for both the actual and model stacks were >10,000. An additional criterion is that the product of the hydraulic diameter and mean velocity (DV) of the full-scale stack must be between 1/6 DV and 6 DV of the scale model stack tests. Verification tests of the EMF stack was performed at normal operating conditions. The minimum 1/6 DV value, along with the maximum 6 DV value from the scale model testing determines the range of stack flow rates for which the full-scale stack may be operated and remain in compliance with the stack verification criterion. Based on the LV-S1 scale model test DV values, the corresponding stack flow rates for the EMF stack are as listed in Table S1. Table S1. Effluent Management Facility Stack Qualified Flow Range. Stack Parameter EM-1 Minimum Qualified Stack Flow (scfm) 781 Maximum Qualified Stack Flow (scfm) 53,432 The remaining criteria for the stack verification to be considered valid involve the flow angle and velocity uniformity results. First, the flow angle at the full-scale stack must be =20°. Second, the velocity uniformity at the full-scale stack must be =20% coefficient of variance (COV). Finally, the velocity uniformity results for the actual and scale model stack tests must agree within 5% COV. These criteria were met through the full-scale stack test at the EMF. Flow angle results were less than 5°; all flow angle results were within the =20° criterion. The velocity uniformity results for each test condition ranged between 2.2% COV and 4.3% COV, which were all within the range of the target % COV values from the scale model tests on the LV-S1, LB-S1, and LV S2 scale models. Based on these stack verification test results, the EMF filtered exhaust stack sampling location meets the qualification criteria provided in the ANSI/HPS N13.1-1999 standard for all fan operating configurations. This includes each combination of ACV fan with the DVP exhausters. Further changes to the system configuration or operating conditions that are outside the qualified flow rates described in this report may require additional tests or analyses to determine compliance with the standard.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Improving the Economic Viability of Biological Utilization of Coal Power Plant CO 2 by Improved Algae Productivity and Integration with Wastewater Treatment

The overall goal of this project was to improve the cost-effectiveness of systems using algae to capture and beneficially utilize CO 2 from the flue gas of coal-fired power plants. Algal biomass cultivation is an attractive alternative for carbon capture and utilization because it can uptake more CO 2 per land area than any other photosynthetic crop. Also, the resulting biomass can be used to make valuable large-market commodity products, such as biofuels and animal feed. However, the use of algal carbon capture has been limited by several factors including: (1) high costs for growing algae (>$\$1,300$/ton), (2) large land requirements for algae cultivation, and (3) environmental concerns about the large amount of water and nutrient inputs needed for growing algae. This project has taken direct aim at resolving these key limitations and demonstrated several viable approaches to improve the economic and environmental feasibility of algal carbon capture. In particular, this project demonstrated a significant increase in average annual algal productivity from baseline values of 8 g/m 2 -day to above 20 g/m 2 -day. This supports a much lower projected cost of algae production (<$\$500$/ton) and reduces land requirements by more than 50%. Additionally, this project confirmed the ability to grow multiple algae species with wastewater nutrients, which facilitates the potential for substantial new revenue streams for algae cultivation based on tipping fees for nutrient laden wastewater. This study highlighted that there is more potential value in wastewater nutrient treatment credits than in the primary commodity products made from algae. The use of wastewater inputs also mitigates the concerns associated with the large amount of water needed for growing algae. The algal biomass grown for this project using wastewater and simulated flue gas inputs were characterized for potential use as an animal feed ingredient. The algae had a protein content in the range of 35-40%, which is between some common commodity animal feed products— distiller’s grains (~25-30% protein) and soybean meal (45-50% protein). In-vitro digestion tests using cattle rumen fluids, showed that this algae biomass was best suited for use as “bypass protein”, which is digested in the animal intestine. Based on the protein content and amino acid profile of the algae grown in this study, it was estimated to have market value in the range of $\$190$-$\$280$/ton. There is potential for higher value feed products if the algae content of omega-3 fatty acids or antioxidants is accounted for. This project also did small scale demonstration of forward osmosis algae dewatering and nanofiltration of hydrothermal liquefaction aqueous products, which were shown to improve the cost and energy balance for producing algal products. When all the improvements demonstrated in this study were included in techno-economic analysis, it showed there was a viable pathway to profitable algal CO 2 utilization with a payback period in the range of six to ten years.

01 COAL, LIGNITE, AND PEAT↗

Anti-Biofouling Surface Treatments for Improved Condenser Performance for Coal-Based Power Plants

Condenser performance is a critical area for improving the economic efficiency of coal-based power facilities, since more than 50% of generated heat is lost during condenser operation. Decline in condenser performance due to fouling of condenser heat transfer tubes greatly has a significant and detrimental effect on power plant efficiency and controlling biofilm formation remains a major operational challenge. Biofilm formation in condenser tubes decreases the effective diameter for cooling water and increases the surface roughness, which increases the hydraulic resistance of each tube. In addition, biofouling can result in the degradation of the condenser tubing by facilitating corrosion. Therefore, this project aims to develop novel surface treatments and secondarily applied remediation components to mitigate biofilm growth on condenser tube surfaces used in coal-fueled power plants.

01 COAL, LIGNITE, AND PEAT↗

Evaluation of E-beam for wastewater and biosolids treatment applications.

The purpose of this study is to treat samples from various areas in the Chicago Metropolitan Water Reclamation District (MWRD) treatment process using the Accelerator Applications Development and Demonstration (A2D2) machine at Fermilab’s Illinois Accelerator Research Center (IARC), for the purpose of evaluating the effectiveness of e-beam processing for removal of pathogens, removal of contaminants, and increased energy recovery.

43 PARTICLE ACCELERATORS↗

Trace Element Sampling and Partitioning Modeling to Estimate Wastewater Composition and Treatment Performance at Coal Generators

The coal combusted at coal-fired power plants (CFPPs) contains several trace elements that impact human heath if released to the environment. Effective combinations of air pollution control devices (APCDs) and water pollution control devices (WPCDs) are critical to reducing these impacts. This work sampled pulverized CFPPs owned and operated by Louisville Gas & Electricity – Kentucky Utilities (LGE-KU) during baseload and cycling conditions. Next, an open-source and easy-to-implement trace element partitioning model was developed using publicly available datasets, literature studies of trace element partitioning, and sampling data to estimate trace element partitioning in APCDs to the gas, liquid, and solid phases exiting CFPPs. These estimates of the liquid phase trace element concentration in FGD wastewater were then used to estimate trace element behavior in WPCDs and evaluate treated wastewater effluent concentrations for compliance with the Effluent Limitation Guidelines (ELG) for the Steam Electric Generating Sector. Finally, cost estimates were developed for established and emerging wastewater treatment trains to identify the most cost-effective approaches for ELG compliance.

01 COAL, LIGNITE, AND PEAT↗

National Energy Water Treatment & Speciation (NEWTS): A Water & Critical Minerals Database and Dashboard

The poster, presented at the American Geophysical Union (AGU) 2023 Conference, highlights NETL's National Energy Water Treatment & Speciation (NEWTS) Database & Dashboard. This poster reviews the work done to aggregate disparate water quality data for energy-related wastewater streams, to process and integrate the datasets, and enable easy integration with aqueous chemistry modeling software to support water management and beneficial reuse decision-making.

Wenzlick, Madison↗

Compact Superconducting RF Accelerators for Water Treatment

Jefferson Lab is actively exploring the environmental applications of compact irradiation facilities utilizing Superconducting Radio Frequency (SRF) accelerator technology ? a well-established technology primarily used in large research machines. Recent advancements, such as the application of thin films of superconducting alloys in radio frequency (RF) resonators and the development of high-capacity cryocoolers, have made it feasible to employ this key technology in compact, standalone irradiation facilities. The main advantage over conventional systems based on normal conducting technology is the significantly enhanced efficiency in beam power generation, enabling exposure to substantially higher radiation doses. In the realm of addressing contaminants in wastewater treatment, particularly concerning persistent substances known as "forever chemicals," this technology presents an attractive solution, given the required considerable effort i.e. dose to break them down. Experiment Numbers:

Vennekate, John↗

Sister Rod Destructive Examinations (FY23) Appendix A: Full-Length Rod Heat Treatments

As a part of DOE NE High Burnup Spent Fuel Data Project, Oak Ridge National Laboratory (ORNL) is performing destructive examinations (DEs) of high burnup (HBU) (>45 GWd/MTU) spent nuclear fuel (SNF) rods from the North Anna Nuclear Power Station operated by Dominion Energy. The SNF rods, called sister rods or sibling rods, are all HBU and include four different kinds of fuel rod cladding: standard Zircaloy-4 (Zirc-4), low-tin Zirc-4, ZIRLO, and M5. The DEs are being conducted to obtain a baseline of the HBU rod’s condition before dry storage and are focused on understanding overall SNF rod strength and durability. Composite fuel and defueled cladding will be tested to derive material properties. Although the data generated can be used for multiple purposes, one primary goal for obtaining the post-irradiation examination data and the associated measured mechanical properties is to support SNF dry storage licensing and relicensing activities by (1) addressing identified knowledge gaps and (2) enhancing the technical basis for post-storage transportation, handling, and subsequent disposition. This report documents the status of the ORNL Phase 1 DE activities related to full-length rod heat treatments (FHT) applied to selected sister rods in Phase 1 of the sister rod test program.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Comparison of Temperature-Dependent Cross Section Treatments Within the Shift Monte Carlo Radiation Transport Code

Multiple calculation methods have been developed to account for Doppler broadening of cross sections in Monte Carlo radiation transport simulations. This work compares the accuracy and performance of four different broadening methods, including an on-the-fly multipole treatment, applied to three different geometries of increasing complexity, including a nuclear reactor assembly with a realistic temperature profile. The comparisons reveal how the combination of physics implementations in the Shift Monte Carlo code result in slightly different temperature-dependent behavior, and different levels of performance, for a variety of materials and situations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Hanford Waste Treatment Plant Low Activity Waste Facility Stack Effluent Monitoring: Sampling Probe Location Qualification Evaluation (Rev.1)

The Hanford Tank Waste Treatment and Immobilization Plant Low Activity Waste (LAW) facility stack monitor locations were qualified using scale model stacks to mitigate the risk of discovering that sampling locations do not meet the qualification criteria on the full-scale stacks. As required by the American National Standards Institute/Health Physics Society (ANSI/HPS) N13.1-1999 standard, the scale model and its sampling location were geometrically similar to the actual stack and the Reynolds numbers for both the actual and model stacks were >10,000. An additional criterion is that the product of the hydraulic diameter and mean velocity (DV) of the full-scale stack must be between 1/6 DV and 6 DV of the scale model stack tests. Verification tests of the LAW stacks were performed at normal operating conditions. The minimum 1/6 DV value, along with the maximum 6 DV value from the scale model testing, determines the range of stack flow rates for which the full-scale stack may be operated and remain in compliance with the stack verification criterion. For this analysis, the range of qualified flow rates listed is conservatively based on the average DV through 6 DV for LV-S1, LV-S2, and LV-C2, and 1/3 DV to 3 DV for LV-S3. Table S1 lists the operating flow rates along with the conservative lower and upper qualified stack flow rates for each of the LAW facility stacks. For each stack, the operating flow is below the upper qualified stack.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Hanford Waste Treatment Plant LAB Facility Stack Effluent Monitoring: Sampling Probe Location Qualification Evaluation

The Waste Treatment Plant laboratory (LAB) facility stack monitor locations were qualified using scale model stacks to mitigate the risk of identifying that sampling locations do not meet the qualification criteria on the full-scale stack. As required by the American National Standards Institute/Health Physics Society (ANSI/HPS) N13.1-1999 standard, the scale model and its sampling location were geometrically similar to the actual stack, and the Reynolds numbers for both the actual and model stacks were >10,000. An additional criterion is that the product of the hydraulic diameter and mean velocity (DV) of the full-scale stack must be between 1/6 DV and 6 DV of the scale model stack tests. Verification tests of the LAB stacks were performed at normal operating conditions. The minimum 1/6 DV value, along with the maximum 6 DV value from the scale model testing, determines the range of conditions for which the full-scale stack may be operated and remain in compliance with the stack verification criterion. A practical range for the full-scale stack qualification uses the average DV through 6 DV from the scale model tests to compute the corresponding flow rates. Table S1 lists the operating flow rates along with the average and maximum qualified stack flow rates for each of the LAB facility stacks. For each stack, the operating flow is below the maximum qualified stack flow, which means that the scale model test results are acceptable for stack qualification. The remaining criteria for the stack verification to be considered valid involve the flow angle and velocity uniformity results. First, the flow angle at the full-scale stack must be ≤20°. Second, the velocity uniformity at the full-scale stack must be ≤20% coefficient of variance (COV). Finally, the velocity uniformity results for the actual and scale model stack tests must agree within 5% COV. These criteria were met through the full-scale stack tests at the LAB facility. Flow angle results were primarily less than 10°, except for the LB-C2 Fan A results, which were an average of 13.7°; all flow angle results were within the ≤20° criterion. The velocity uniformity results for each test condition averaged between 1.5 and 4.1% COV, which were all within the range of the target percent coefficient of variation values from the scale model tests. Based on these stack verification test results, the three LAB filtered exhaust stack sampling locations meet the qualification criteria provided in the ANSI/HPS N13.1-1999 standard for all fan operating configurations. This includes single-fan as well as dual-fan operations for LB-C2, each of the dual-fan operating conditions for LB-S1, and each single-fan operating condition for LB-S2. Further changes to the system configuration or operating conditions that are outside the bounds described in this report may require additional tests or analyses to determine compliance with the standard.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗