Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “testing statistics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 865 records · Page 48

Reconstructing the history of structure formation using redshift distortions

Measuring the statistics of galaxy peculiar velocities using redshift-space distortions is an excellent way of probing the history of structure formation. Because galaxies are expected to act as test particles within the flow of matter, this method avoids uncertainties due to an unknown galaxy density bias. We show that the parameter combination measured by redshift-space distortions, fσ{sub 8}{sup mass} provides a good test of dark energy models, even without the knowledge of bias or σ{sub 8}{sup mass} required to extract f from this measurement (here f is the logarithmic derivative of the linear growth rate, and σ{sub 8}{sup mass} is the root-mean-square mass fluctuation in spheres with radius 8h{sup −1}Mpc). We argue that redshift-space distortion measurements will help to determine the physics behind the cosmic acceleration, testing whether it is related to dark energy or modified gravity, and will provide an opportunity to test possible dark energy clumping or coupling between dark energy and dark matter. If we can measure galaxy bias in addition, simultaneous measurement of both the overdensity and velocity fields can be used to test the validity of equivalence principle, through the continuity equation.

79 ASTRONOMY AND ASTROPHYSICS↗

TU-D-207B-03: Early Assessment of Response to Chemoradiotherapy Based On Textural Analysis of Pre and Mid-Treatment FDG-PET Image in Locally Advanced Head and Neck Cancer

Purpose: To evaluate whether tumor textural features extracted from both pre- and mid-treatment FDG-PET images predict early response to chemoradiotherapy in locally advanced head and neck cancer, and investigate whether they provide complementary value to conventional volume-based measurements. Methods: Ninety-four patients with locally advanced head and neck cancers were retrospectively studied. All patients received definitive chemoradiotherapy and underwent FDG-PET planning scans both before and during treatment. Within the primary tumor we extracted 6 textural features based on gray-level co-occurrence matrices (GLCM): entropy, dissimilarity, contrast, correlation, energy, and homogeneity. These image features were evaluated for their predictive power of treatment response to chemoradiotherapy in terms of local recurrence free survival (LRFS) and progression free survival (PFS). Logrank test were used to assess the statistical significance of the stratification between low- and high-risk groups. P-values were adjusted for multiple comparisons by the false discovery rate (FDR) method. Results: All six textural features extracted from pre-treatment PET images significantly differentiated low- and high-risk patient groups for LRFS (P=0.011–0.038) and PFS (P=0.029–0.034). On the other hand, none of the textural features on mid-treatment PET images was statistically significant in stratifying LRFS (P=0.212–0.445) or PFS (P=0.168–0.299). An imaging signature that combines textural feature (GLCM homogeneity) and metabolic tumor volume showed an improved performance for predicting LRFS (hazard ratio: 22.8, P<0.0001) and PFS (hazard ratio: 13.9, P=0.0005) in leave-one-out cross validation. Intra-tumor heterogeneity measured by textural features was significantly lower in mid-treatment PET images than in pre-treatment PET images (T-test: P<1.4e-6). Conclusion: Tumor textural features on pretreatment FDG-PET images are predictive for response to chemoradiotherapy in locally advanced head and neck cancer. The complementary information offered by textural features improves patient stratification and may potentially aid in personalized risk-adaptive therapy.

60 APPLIED LIFE SCIENCES↗

Radiological Characterisation of VLLW Produced at High-Energy Particle Accelerators - 19118

In this paper we describe the characterisation method of very-low-level radioactive waste (VLLW) produced at the European Organization for Nuclear Research (CERN). The method is based on the calculation of a preliminary radionuclide inventory using either analytical or Monte Carlo codes, on the measurement of γ-emitters and on the quantification of pure-α, pure-β and low-energy X-ray emitters, called difficult-to-measure (DTM) radionuclides, using the so-called scaling factor (SF) technique. The first stage of the characterisation process is the calculation of the radionuclide inventory, which is a list of radionuclides that can potentially be produced via the interaction of primary and secondary particles with the surrounding media. Once the preliminary radionuclide inventory is obtained, the γ-emitting radionuclides are measured via γ-ray spectrometry on each package of the waste population. The major γemitter, called key nuclide (KN), is also identified. The scaling factor method estimates the activity of DTM radionuclides by checking for a consistent and repeated relationship between the key nuclide and the activity of the difficult to measure radionuclides from samples. Between 2016 and 2018, several hundred samples were collected at CERN and over 1000 radiochemical analyses were performed to estimate robust statistics to quantify scaling factors for the most common DTM radionuclides, such as H-3, Fe-55 and Ni-63. This paper illustrates the sample collection strategy, the tests performed to choose the most appropriate statistical models describing the behaviour of scaling factors and a complete quantification of the uncertainties associated with the characterisation process. Finally, we present the results obtained during the characterisation of over 2000 m{sup 3} radioactive metals and cables disposed of at the French National repository for VLLW. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Detecting inhomogeneities in the Twentieth Century Reanalysis over the central United States

The Twentieth Century Reanalysis (20CR), which spans the 138 year period from 1871 to 2008, was intended for a variety of climate applications, including long–term trend assessment. Because over land 20CR only assimilates surface pressure observations and their count increases by an order of magnitude over the course of the record, a key question is whether the 20CR is homogenous and hence suitable for detecting climate–related changes. We use three statistical methods (Pettitt and Bai–Perron tests and segmented regression) to detect abrupt shifts in multiple hydrometeorological variable mean and uncertainty fields over the central United States. For surface air temperature and precipitation, we use the Climate Research Unit (CRU) time series data set for comparison. We find that for warm–season months, there is a consensus change point among all variables between 1940 and 1950, which is not substantiated by the CRU record. While we cannot say with certainty that these shifts in the 20CR analysis fields are artificial, our statistical analyses, coupled with a visual inspection of the underlying assimilated observational count time series, strongly point to this conclusion. Furthermore, our recommendation is therefore for users to restrict climate trend applications over the central United States to the second half century of the 20CR record, after observational density has stabilized.

54 ENVIRONMENTAL SCIENCES↗

Statistically Significant Evidence of a Release of Zinc from Pit 1 at the Lawrence Livermore National Laboratory Experimental Test Site 300 (90-Day Report)

Lawrence Livermore National Laboratory (LLNL) is submitting this 90-Day Report in accordance with Waste Discharge Requirements Order No. 93-100, Provision 4. This letter report is provided in reference to several seven-day letters in which LLNL reported that ground water sample analytical results from monitoring wells Kl-05, Kl-08, Kl-09, and W-PITl-2326 indicated "statistically significant evidence of a release" of zinc from LLNL's Site 300 Experimental Test Facility landfillPit 1 (Figure 1).

54 ENVIRONMENTAL SCIENCES↗

Adaptive time-stepping Monte Carlo integration of Coulomb collisions

Here, we report an accessible and robust tool for evaluating the effects of Coulomb collisions on a test particle in a plasma that obeys Maxwell–Jüttner statistics. The implementation is based on the Beliaev–Budker collision integral which allows both the test particle and the background plasma to be relativistic. The integration method supports adaptive time stepping, which is shown to greatly improve the computational efficiency. The Monte Carlo method is implemented for both the three-dimensional particle momentum space and the five-dimensional guiding center phase space.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Poster - 56: Preliminary comparison of FF- and FFF-VMAT for prostate plans with higher rectal dose

Purpose: A recent retrospective study found 53 patients previously treated to 78Gy/39 using flattened filtered (FF) 6X-VMAT at GRRCC had rectal DVH more than one standard deviation higher than the average. This study was to investigate if using 6FFFor10FFF beams could reduce these DVHs without compromising target coverage. Methods: Twenty patients’ plans were re-planed with 2-arc 6X-VMAT, 6FFF-VMAT and 10FFF-VMAT using the Eclipse TPS following departmental protocol. All plans had the same optimization and normalization, and were evaluated against the acceptance criteria from the QUANTEC and Emami. Statistical differences in the mean dose to OARs (D{sub m}) and PTV homogeneity index (HI) between energies were tested using the paired sample Wilcoxon signed rank statistical method (p<0.05). Beam delivery accuracy was checked on five patients using portal dosimetry (PD). Results: The PTV HI for the 10FFF shows no statistical difference from the 6X. All the OARs, except left femoral head with 6FFF, have significantly lower Dm using 6FFF and 10FFF .There is no difference in the maximum doses to rectum and bladder and are limited by the prescribed doses. Measurements show good agreements in the gamma evaluation (3%/3mm) for all energies. Conclusion: This preliminary study shows that doses to the OARs are reduced using 10FFF for the same target coverage. The plans using 6FFF result in lower doses to some OARs, and statistically different PTV HI. All plans showed very good agreement with measurements.

60 APPLIED LIFE SCIENCES↗

Modeling the target dose fall-off in IMRT and VMAT planning techniques for cervical SBRT

There has been growing interest in the use of stereotactic body radiotherapy (SBRT) technique for the treatment of cervical cancer. The purpose of this study was to characterize dose distributions as well as model the target dose fall-off for intensity-modulated radiation therapy (IMRT) and volumetric-modulated arc therapy (VMAT) delivery techniques using 6 and 10 MV photon beam energies. Fifteen (n = 15) patients with non-bulky cervical tumors were planned in Pinnacle{sup 3} with a Varian Novalis Tx (HD120 MLC) using 6 and 10 MV photons with the following techniques: (1) IMRT with 10 non-coplanar beams (2) dual, coplanar 358° VMAT arcs (4° spacing), and (3) triple, non-coplanar VMAT arcs. Treatment volumes and dose prescriptions were segmented according to University of Texas Southwestern (UTSW) Phase II study. All plans were normalized such that 98% of the planning target volume (PTV) received 28 Gy (4 fractions). For the PTV, the following metrics were evaluated: homogeneity index, conformity index, D{sub 2cc}, D{sub mean}, D{sub max}, and dose fall-off parameters. For the organs at risk (OARs), D{sub 2cc}, D{sub 15cc}, D{sub 0.01cc}, V{sub 20}, V{sub 40}, V{sub 50}, V{sub 60}, and V{sub 80} were evaluated for the bladder, bowel, femoral heads, rectum, and sigmoid. Statistical differences were evaluated using a Friedman test with a significance level of 0.05. To model dose fall-off, expanding 2-mm-thick concentric rings were created around the PTV, and doses were recorded. Statistically significant differences (p 3-arc , as compared with IMRT. VMAT{sub 3-arc} improved the bladder V{sub 40}, V{sub 50}, and V{sub 60}, and the bowel V{sub 20} and V{sub 50}. All fitted regressions had an R{sup 2} ≥ 0.98. For cervical SBRT plans, a VMAT{sub 3-arc} approach offers a steeper dose fall-off outside of the target volume. Faster dose fall-off was observed in smaller targets as opposed to medium and large targets, denoting that OAR sparing is dependent on target size. These improvements are further pronounced with the use of 10-MV photons.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Towards Malware Detection via CPU Power Consumption: Data Collection Design and Analytics

This paper presents an experimental design and data analytics approach aimed at power-based malware detection on general-purpose computers. Leveraging the fact that malware executions must consume power, we explore the postulate that malware can be accurately detected via power data analytics. Our experimental design and implementation allow for programmatic collection of CPU power profiles for fixed tasks during uninfected and infected states using five different rootkits. To characterize the power consumption profiles, we use both simple statistical and novel, sophisticated features. We test a one-class anomaly detection ensemble (that baselines non-infected power profiles) and several kernel-based SVM classifiers (that train on both uninfected and infected profiles) in detecting previously unseen malware and clean profiles. The anomaly detection system exhibits perfect detection when using all features and tasks, with smaller false detection rate than the supervised classifiers. The primary contribution is the proof of concept that baselining power of fixed tasks can provide accurate detection of rootkits. Moreover, our treatment presents engineering hurdles needed for experimentation and allows analysis of each statistical feature individually. This work appears to be the first step towards a viable power-based detection capability for general-purpose computers, and presents next steps toward this goal.

Bridges, Robert↗

A Comparison of daily megavoltage CT and ultrasound image guided radiation therapy for prostate cancer

In order to quantify the differences between ultrasound-imaging and megavoltage-CT (MVCT) daily prostate localization in prostate-cancer radiotherapy and their dosimetric impacts, daily shifts were analyzed for a total of 140 prostate cancer patients; 106 positioned using ultrasound-based imaging [B-mode Acquisition and Targeting (BAT)], and 34 using the MVCT from a TomoTherapy Hi-Art unit. The shifts indicated by the two systems were compared statistically along the right/left (R/L), superior/inferior (S/I), and anterior/posterior (A/P) directions. The systematic and random variations among the daily alignments were calculated. Margins to account for these shifts were estimated. The mean shifts and standard deviations along the R/L, S/I, and A/P directions were -0.11{+-}3.80, 0.67{+-}4.67, and 2.71{+-}6.31 mm for BAT localizations and -0.98{+-}5.13, 0.27{+-}3.35, and 1.00{+-}4.22 mm for MVCT localizations, respectively. The systematic and random variations in daily shifts based on MVCT were generally smaller than those based on BAT, especially along the A/P direction. A t-test showed this difference to be statistically significant. The planning target volume margins in the A/P direction estimated to account for daily variations were 8.81 and 14.66 mm based on MVCT and BAT data, respectively. There was no statistically significant difference in the daily prostate movement pattern between the first few fractions and the remaining fractions. Dosimetric comparison of MVCT and BAT prostate alignments was performed for seven fractions from a patient. The degradation from the plan caused by the MVCT alignment is trivial, while that by BAT is substantial. The MVCT technique results in smaller variations in daily shifts than ultrasound imaging, indicating that MVCT is more reliable and precise for prostate localization. Ultrasound-based localization may overestimate the daily prostate motion, particularly in the A/P direction, negatively impacting prostate dose coverage and rectal sparing.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-J-232: Feasibility of MRI-Based Preplan On Low Dose Rate Prostate Brachytherapy

Purpose: To investigate the feasibility of using MRI-based preplan for low dose rate prostate brachytherapy. Methods: 12 patients who received transrectal ultrasound (TRUS) guided prostate brachytherapy with Pd-103 were retrospectively studied. Our care-standard of the TRUS-based preplan served as the control. One or more prostate T2-weighted wide and/or narrow-field of view MRIs obtained within the 3 months prior to the implant were imported into the MIM Symphony software v6.3 (MIM Software Inc., Cleveland, OH) for each patient. In total, 37 MRI preplans (10 different image sequences with average thickness of 4.8mm) were generated. The contoured prostate volume and the seed counts required to achieve adequate dosimetric coverage from TRUS and MRI preplans were compared for each patient. The effects of different MRI sequences and image thicknesses were also investigated statistically using Student’s t-test. Lastly, the nomogram from the MRI preplan and TRUS preplan from our historical treatment data were compared. Results: The average prostate volume contoured on the TRUS and MRI were 26.6cc (range: 12.6∼41.3cc), and 27.4 cc (range: 14.3∼50.0cc), respectively. Axial MRI thicknesses (range: 3.5∼8.1mm) did not significantly affect the contoured volume or the number of seeds required on the preplan (R2 = 0.0002 and 0.0012, respectively). Four of the MRI sequences (AX-T2, AX-T2-Whole-Pelvis, AX-T2-FSE, and AXIALT2- Hi-Res) showed statistically significant better prostate volume agreement with TRUS than the other seven sequences (P <0.01). Nomogram overlay between the MRI and TRUS preplans showed good agreement; indicating volumes contoured on MRI preplan scan reliably predict how many seeds are needed for implant. Conclusion: Although MRI does not allow for determination of the actual implant geometry, it can give reliable volumes for seed ordering purposes. Our future work will investigate if MRI is sufficient to reliably replace TRUS preplanning in patients where preplan TRUS may be technically challenging.

60 APPLIED LIFE SCIENCES↗

Cerebral Cortex Regions Selectively Vulnerable to Radiation Dose-Dependent Atrophy

Purpose and Objectives: Neurologic deficits after brain radiation therapy (RT) typically involve decline in higher-order cognitive functions such as attention and memory rather than sensory defects or paralysis. We sought to determine whether areas of the cortex critical to cognition are selectively vulnerable to radiation dose-dependent atrophy. Methods and Materials: We measured change in cortical thickness in 54 primary brain tumor patients who underwent fractionated, partial brain RT. The study patients underwent high-resolution, volumetric magnetic resonance imaging (T1-weighted; T2 fluid-attenuated inversion recovery, FLAIR) before RT and 1 year afterward. Semiautomated software was used to segment anatomic regions of the cerebral cortex for each patient. Cortical thickness was measured for each region before RT and 1 year afterward. Two higher-order cortical regions of interest (ROIs) were tested for association between radiation dose and cortical thinning: entorhinal (memory) and inferior parietal (attention/memory). For comparison, 2 primary cortex ROIs were also tested: pericalcarine (vision) and paracentral lobule (somatosensory/motor). Linear mixed-effects analyses were used to test all other cortical regions for significant radiation dose-dependent thickness change. Statistical significance was set at α = 0.05 using 2-tailed tests. Results: Cortical atrophy was significantly associated with radiation dose in the entorhinal (P=.01) and inferior parietal ROIs (P=.02). By contrast, no significant radiation dose-dependent effect was found in the primary cortex ROIs (pericalcarine and paracentral lobule). In the whole-cortex analysis, 9 regions showed significant radiation dose-dependent atrophy, including areas responsible for memory, attention, and executive function (P≤.002). Conclusions: Areas of cerebral cortex important for higher-order cognition may be most vulnerable to radiation-related atrophy. This is consistent with clinical observations that brain radiation patients experience deficits in domains of memory, executive function, and attention. Correlations of regional cortical atrophy with domain-specific cognitive functioning in prospective trials are warranted.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

AMIE (ARM MJO Investigation Experiment): Observations of the Madden-Julian Oscillation for Modeling Studies Science Plan

Deep convection in the tropics plays an important role in driving global circulations and the transport of energy from the tropics to the mid-latitudes. Understanding the mechanisms that control tropical convection is a key to improving climate modeling simulations of the global energy balance. One of the dominant sources of tropical convective variability is the Madden-Julian Oscillation (MJO), which has a period of approximately 30–60 days. There is no agreed-upon explanation for the underlying physics that maintain the MJO. Many climate models do not show well-defined MJO signals, and those that do have problems accurately simulating the amplitude, propagation speed, and/or seasonality of the MJO signal. Therefore, the MJO is a very important modeling target for the ARM modeling community geared specifically toward improving climate models. The ARM MJO Investigation Experiment (AMIE) period coincides with a large international MJO initiation field campaign called CINDY2011 (Cooperative Indian Ocean experiment on intraseasonal variability in the Year 2011) that will take place in and around the Indian Ocean from October 2011 to January 2012. AMIE, in conjunction with CINDY2011 efforts, will provide an unprecedented data set that will allow investigation of the evolution of convection within the framework of the MJO. AMIE observations will also complement the long-term MJO statistics produced using ARM Manus data and will allow testing of several of the current hypotheses related to the MJO phenomenon. Taking advantage of the expected deployment of a C-POL scanning precipitation radar and an ECOR surface flux tower at the ARM Manus site, we propose to increase the number of sonde launches to eight per day starting in about mid-October of the field experiment year, which is climatologically a period of generally suppressed conditions at Manus and just prior to the climatologically strongest MJO period. The field experiment will last until the end of the MJO season (typically March), affording the documentation of conditions before, during, and after the peak MJO season. The increased frequency of sonde launches throughout the experimental period will provide better diurnal understanding of the thermodynamic profiles, and thus a better representation within the variational analysis data set. Finally, a small surface radiation and ceilometer system will be deployed at the PNG Lombrum Naval Base about 6 km away from the ARM Manus site in order to provide some documentation of scale variability with respect to the representativeness of the ARM measurements.

54 ENVIRONMENTAL SCIENCES↗

Active helium target: Neutron scalar polarizability extraction via Compton scattering

Precise measurement of the neutron scalar polarizabilities has been a lasting challenge because of the lack of a free-neutron target. Led by the University of Glasgow and the Mount Allison University groups of the A2 collaboration in Mainz, Germany, preparations have begun to test a recent theoretical model with an active helium target with the hope of determining these elusive quantities with small statistical, systematic, and model-dependent errors. Apparatus testing and background-event simulations have been carried out, with the full experiment projected to run in 2015. Once determined, these values can be applied to help understand quantum chromodynamics in the nonperturbative region.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Sci-Fri AM: Quality, Safety, and Professional Issues 05: QC Program Management and the Benefits of QATrack+

Purpose: Treatment unit uptime statistics are typically used to monitor radiation equipment performance. The Ottawa Hospital Cancer Centre has introduced the use of Quality Control (QC) test success as a quality indicator for equipment performance and overall health of the equipment QC program. Methods: Implemented in 2012, QATrack+ is used to record and monitor over 1100 routine machine QC tests each month for 20 treatment and imaging units ( http://qatrackplus.com/ ). Using an SQL (structured query language) script, automated queries of the QATrack+ database are used to generate program metrics such as the number of QC tests executed and the percentage of tests passing, at tolerance or at action. These metrics are compared against machine uptime statistics already reported within the program. Results: Program metrics for 2015 show good correlation between pass rate of QC tests and uptime for a given machine. For the nine conventional linacs, the QC test success rate was consistently greater than 97%. The corresponding uptimes for these units are better than 98%. Machines that consistently show higher failure or tolerance rates in the QC tests have lower uptimes. This points to either poor machine performance requiring corrective action or to problems with the QC program. Conclusions: QATrack+ significantly improves the organization of QC data but can also aid in overall equipment management. Complimenting machine uptime statistics with QC test metrics provides a more complete picture of overall machine performance and can be used to identify areas of improvement in the machine service and QC programs.

60 APPLIED LIFE SCIENCES↗

The Coupled Location/Depth/Yield Problem for North Korea’s Declared Nuclear Tests

On 3 September 2017, the Democratic People's Republic of Korea (DPRK) conducted its sixth and largest declared nuclear test at the Pung'gye Ri test site. Recently, we have been using regional waveform envelopes to estimate the explosive yield and overburden of chemical and nuclear explosions by coupling explosion source models to propagation parameters. Like most yield determination methods, there can be tradeoffs between yield and depth, leading to uncertainties in both parameters. The relative locations are well-constrained by small timing differences in seismic-phase arrivals at stations that recorded multiple events, but there are potential uncertainties on the absolute locations. Depths are poorly constrained by the relative arrival times. In this study, we have performed a coupled location and yield analysis of the DPRK nuclear tests. We use correlation methods to get highly accurate travel times and relative locations using a Bayesian location method. Then, while keeping the relative locations of the six tests constant, we consider the consequences of shifts to the absolute locations on the resulting overburden for each event. Given that overburden, we determine the yield that minimizes the waveform misfit. We also test and compare a number of explosion source models. By considering the coupled location/depth/yield problem, we reduce uncertainties in the absolute locations, and yield and depth estimates of the events. Based on statistical analysis, we estimate that the 2017 test has a yield of 125 kilotons (equivalent TNT) with a 1 sigma uncertainty range of 103-150 ktons at about 600 m of overburden.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Long-term Dynamical Stability in the Outer Solar System. I. The Regular and Chaotic Evolution of the 34 Largest Trans-Neptunian Objects

We carried out an extensive analysis of the stability of the outer solar system, making use of the frequency analysis technique over short-term integrations of nearly 100,000 test particles, as well as a statistical analysis of 200 1 Gyr long numerical simulations, which consider the mutual perturbations of the giant planets and the 34 largest trans-Neptunian objects (we have called all 34 objects “dwarf planets,” DPs, even if probably only the largest of them are true DPs). From the frequency analysis, we produced statistical diffusion maps for a wide region of the a–e phase-space plane; we also present the average diffusion time for orbits as a function of perihelion. We later turned our attention to the 34 DPs, making an individualized analysis for each of them and producing a first approximation of their future stability. From the 200 distinct realizations of the orbital evolution of the 34 DPs, we classified the sample into three categories, including 17 stable, 11 unstable, and 6 resonant objects; we also found that, statistically, two objects from the sample will leave the trans-Neptunian region within the next gigayear, most likely being ejected from the solar system, but with a nonnegligible probability of going inside the orbit of Neptune, either to collide with a giant planet or even falling to the inner solar system, where our simulations are no longer able to resolve their continuous evolution.

79 ASTRONOMY AND ASTROPHYSICS↗

Effects of Electromagnetic Fields on Fish and Invertebrates: Task 2.1.3: Effects on Aquatic Organisms

This fiscal year (FY) 2011 progress report (Task 2.1.3 Effects on Aquatic Organisms, Subtask 2.3.1.1 Electromagnetic Fields) describes studies conducted by PNNL as part of the DOE Wind and Water Power Program to examine the potential effects of electromagnetic fields (EMF) from marine and hydrokinetic devices on aquatic organisms, including freshwater and marine fish and marine invertebrates. In this report, we provide a description of the methods and results of experiments conducted in FY 2010-FY 2011 to evaluate potential responses of selected aquatic organisms. Preliminary EMF laboratory experiments during FY 2010 and 2011 entailed exposures with representative fish and invertebrate species including juvenile coho salmon (Oncorhynchus kisutch), Atlantic halibut (Hippoglossus hippoglossus), California halibut (Paralicthys californicus), rainbow trout (Oncorhynchus mykiss), and Dungeness crab (Metacarcinus magister). These species were selected for their ecological, commercial, and/or recreational importance, as well as their potential to encounter an MHK device or transmission cable during part or all of their life cycle. Based on previous studies, acute effects such as mortality were not expected to occur from EMF exposures. Therefore, our measurement endpoints focused on behavioral responses (e.g., detection of EMF, interference with feeding behavior, avoidance or attraction to EMF), developmental changes (i.e., growth and survival from egg or larval stage to juvenile), and exposure markers indicative of physiological responses to stress. EMF intensities during the various tests ranged from 0.1 to 3 millitesla, representing a range of upper bounding conditions reported in the literature. Experiments to date have shown there is little evidence to indicate distinct or extreme behavioral responses in the presence of elevated EMF for the species tested. Several developmental and physiological responses were observed in the fish exposures, although most were not statistically significant. Additional species are currently planned for laboratory testing in the next fiscal year (e.g. an elasmobranch, American lobster) to provide a broader assessment of species important to stakeholders. The collective responses of all species will be assessed in terms of life stage, exposure scenarios, and biological relevance, to address current uncertainties related to effects of EMF on aquatic organisms.

54 ENVIRONMENTAL SCIENCES↗