Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “statistical techniques”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 865 records · Page 48

Measuring the Muon Anomalous Magnetic Moment to High Precision [PowerPoint]

The anomalous magnetic moment of the muon, characterized as the anomaly $a_{\mu} \equiv (g_{\mu}-2)/2$, remains a compelling hint of physics beyond the Standard Model (BSM) in light of the Brookhaven E821 measurement from the early 2000s, which differs with theoretical predictions by $>$3\,$\sigma$. To address this discrepancy, the Muon $g-2$ Experiment at Fermilab (E989) has been designed to determine $a_{\mu}$ to a precision of 140 parts per billion, a four-fold improvement over the E821 measurement. This improved precision presents an excellent opportunity to uncover BSM physics, and at minimum constrain BSM prescriptions. To date, the E989 experiment has completed its first two physics runs, recording more than 3 times the statistics recorded in the E821 experiment. The collaboration is preparing for a third physics run starting in October, with the goal of accumulating a factor of three more data than the previous runs combined, resulting in an order of magnitude more statistics than the Brookhaven measurement. An overview of the experimental technique will be discussed, along with a summary of Run 1 and 2. An update of the analysis of the Run 1 data will be presented; additionally, Run 3 progress will be summarized.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Statistical Framework for Planning a Shelf Life Program with Binary Performance Data

This document outlines a statistical framework for establishing a shelf-life program for components whose performance is measured by a binary response, usually ‘pass’ or ‘fail.’ The approach applies to both single measurement devices and repeated measurement devices. The high-level objective of these plans is to quickly detect any sizeable increase in fraction defective as the product ages. The statistical approach is to choose a sample size and monitoring technique that alarms when the fraction defective increases to an unacceptably high level, but does not alarm when the process is at nominal. The nominal (acceptable) fraction defective is used, and an increased fraction defective (unacceptable) is assumed as part of the control chart design. The control chart recommended for this problem is the Bernoulli Cumulative Sum (CUSUM) control chart.

97 MATHEMATICS AND COMPUTING↗

Transformative Impacts of Laser-Induced Breakdown Spectroscopy on Environmental and Biological Research at Oak Ridge National Laboratory

This manuscript will present an advancement of transformative research that has been conducted at Oak Ridge National Laboratory (ORNL) over a 25-year period (2000–2025) on a variety of environmental and biological matrices. These investigations derived a fundamental understanding of how elemental detection and analysis of these matrices led to the knowledge and discovery of natural processes in plants and the environment. Each project led to the initiation of a new research area which unearthed awesome and novel breakthroughs. Highlights are listed below: 1. The preliminary research at ORNL centered on the detection of aerosols utilizing Laser-induced Breakdown Spectroscopy (LIBS) technology. The Clean Air Act Amendment (CAAA) of 1990 highlighted the importance of identifying hazardous air pollutants (HAPs) due to their impact on environmental and human health, thereby underscoring the need to detect various toxic elements. Research in aerosol chemistry aimed to identify these harmful elements released by factories during periods of increased emissions in their manufacturing processes. LIBS emerged as the most effective method for real-time, in situ measurements of metal species in both gaseous and aerosol phases. 2. An understanding of the presence of total carbon in soils gives perspective on how to develop carbon sequestration strategies. The recognition that carbon sinks can evolve back to carbon sources to emit back to the atmosphere was an important consideration. Also, the concentration of carbon in soil indicates the health of land areas for growing crops successfully. 3. The direct detection of most of the elements in a wood sample in a single emission spectrum, without sample preparation, encouraged the research to use the LIBS technique for preservative treated wood coupled with use of multivariate statistical methodology. Additionally, it encouraged the researchers to try to differentiate natural woods from different parts of the country, and it was successfully demonstrated that LIBS coupled with MVA analysis could differentiate wood of different species from each other and of similar species grown in different environments based on their elemental spectra. This was a breakthrough since it revealed a systematic approach to connect elemental scarcity and abundance to either drought or typical rainfall conditions for the hardwood trees grown in specific areas. 4. Furthermore, the research progressed to reveal physiological and developmental processes contributing to biomass production such that the variation in leaf elemental composition increases our understanding of terrestrial nutrient cycles, as well as tracking the transfer of toxic elements from soils to living organisms. 5. Recently another breakthrough viz., ionomics initiated the correlation of elements to specific genes, uncovering the function that the element performed in the plant. More recently, this has been extended from plants to fungi as well as fungi growing in symbiotic relations with plants.

09 BIOMASS FUELS↗

Disentangling the Black Hole Mass Spectrum with Photometric Microlensing Surveys

Abstract From the formation mechanisms of stars and compact objects to nuclear physics, modern astronomy frequently leverages surveys to understand populations of objects to answer fundamental questions. The population of dark and isolated compact objects in the Galaxy contains critical information related to many of these topics, but is only practically accessible via gravitational microlensing. However, photometric microlensing observables are degenerate for different types of lenses, and one can seldom classify an event as involving either a compact object or stellar lens on its own. To address this difficulty, we apply a Bayesian framework that treats lens type probabilistically and jointly with a lens population model. This method allows lens population characteristics to be inferred despite intrinsic uncertainty in the lens class of any single event. We investigate this method’s effectiveness on a simulated ground-based photometric survey in the context of characterizing a hypothetical population of primordial black holes (PBHs) with an average mass of 30 M ⊙ . On simulated data, our method outperforms current black hole (BH) lens identification pipelines and characterizes different subpopulations of lenses while jointly constraining the PBH contribution to dark matter to ≈25%. Key to robust inference, our method can marginalize over population model uncertainty. We find the lower mass cutoff for stellar origin BHs, a key observable in understanding the BH mass gap, particularly difficult to infer in our simulations. This work lays the foundation for cutting-edge PBH abundance constraints to be extracted from current photometric microlensing surveys.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Evaluation of Brazilian Sugarcane Bagasse Characterization: An Interlaboratory Comparison Study

This paper describes a study of the variability of measured composition for a single bulk sugarcane bagasse conducted across eight laboratories using similar analytical methods, with the purpose of determining the expected variation for compositional analysis performed by different laboratories. The results show good agreement of measured composition within a single laboratory, but greater variability when results are compared among laboratories. These interlaboratory variabilities do not seem to be associated with a specific method or technique or any single piece of instrumentation. The summary censored statistics provide mean values and pooled standard deviations as follows: total extractives 6.7% (0.6%), whole ash 1.5% (0.2%), glucan 42.3% (1.2%), xylan 22.3% (0.5%), total lignin 21.3% (0.4%), and total mass closure 99.4% (2.9%).

09 BIOMASS FUELS↗

Practical Application of Parallel Coordinates for Climate Model Analysis

The determination of relationships between climate variables and the identification of the most significant associations between them in various geographic regions is an important aspect of climate model evaluation. The EDEN visual analytics toolkit has been developed to aid such analysis by facilitating the assessment of multiple variables with respect to the amount of variability that can be attributed to specific other variables. EDEN harnesses the parallel coordinates visualization technique and is augmented with graphical indicators of key descriptive statistics. A case study is presented in which the focus on the Harvard Forest site (42.5378N Lat, 72.1715W Lon) and the Community Land Model Version 4 (CLM4) is evaluated. It is shown that model variables such as land water runoff are more sensitive to a particular set of environmental variables than a suite of other inputs in the 88 variable analysis conducted. The approach presented here allows climate-domain scientists to focus on the most important variables in the model evaluations.

54 ENVIRONMENTAL SCIENCES↗

Direct Observation of Ultralow Vertical Emittance using a Vertical Undulator

In recent work, the first quantitative measurements of electron beam vertical emittance using a vertical undulator were presented, with particular emphasis given to ultralow vertical emittances [K. P. Wootton, et al., Phys. Rev. ST Accel. Beams, 17, 112802 (2014)]. Using this apparatus, a geometric vertical emittance of 0.9 ± 0.3 pm rad has been observed. A critical analysis is given of measurement approaches that were attempted, with particular emphasis on systematic and statistical uncertainties. The method used is explained, compared to other techniques and the applicability of these results to other scenarios discussed.

43 PARTICLE ACCELERATORS↗

A Causal Approach to Model Validation and Calibration

This poster presents a novel method for validation and verification that focuses on identifying causal relationships between data elements, moving beyond traditional statistical and machine learning approaches. These methods employ causal discovery techniques to reveal the underlying mechanisms of data generation. The research utilizes structural causal models and directed acyclic graphs to depict causal relationships. This approach assists in achieving alignment between simulation models and reality.

97 MATHEMATICS AND COMPUTING↗

Suppression of Helium Induced Cracking in Laser Repair Welding of Highly Irradiated Stainless Steels

Welding repair of irradiated nuclear reactor materials such as austenitic stainless steels used for the reactor internals has been challenging due to irradiation generated helium in the material matrix over an extended period of time. In this study, improved laser welding techniques, including the novel Auxiliary Beam Stress Improved (ABSI) technique that proactively manages the stresses during laser repair welding is investigated to substantially reduce or avoid the occurrence of intergranular helium-induced cracking (HeIC). Here, laser weld cladding, with and without ABSI technique, was applied to deposit weld metal on irradiated stainless steel (Type 304 L) blocks with various helium concentrations up to approximately 20 atomic parts per million (appm). Welded samples were cross-sectioned and analyzed using optical and electron microscopes. It was found that, with the improved laser welding techniques, no macroscopic (millimeter-sized) cracks were observed in any of the samples. Microscopic (less than 50 μm) cracks were present in the heat affected zone. Statistical analysis on the sample with the highest helium concentration (~20 appm) reveals that the ABSI technique could effectively reduce the size and amounts of microscopic cracks.

36 MATERIALS SCIENCE↗

Does Intensity Modulation Improve Healthy Tissue Sparing in Stereotactic Radiosurgery of Complex Arteriovenous Malformations?

This planning study evaluates the potential of intensity modulated treatment fields and inverse planning techniques in stereotactic radiosurgery to reduce healthy tissue dose. Twenty patients previously treated with stereotactic radiosurgery for arteriovenous malformation (AVM) were replanned with each of 4 techniques: circular non-coplanar arcs, dynamic arcs, static conformal fields, and intensity modulated radiosurgery (IMRS). Patients were selected having a maximum AVM dimension at least 20 mm, or volume greater than 10 cm{sup 3}. Target volumes ranged from 2.12 cm{sup 3} to 13.87 cm{sup 3} with a median of 6.03 cm{sup 3}. Resulting dose distributions show a statistically significant improvement in target conformality between circular arcs and all other techniques (p {<=} 0.001), between conformal and both dynamic arcs and IMRS (p {<=} 0.03) and with no difference between dynamic arcs and IMRS. However, for AVMs of volume greater than 5.5 cm{sup 3}, IMRS gives better conformality than dynamic arcs (p = 0.04). IMRS showed consistently lower dose inhomogeneity compared to both dynamic arcs and conformal fields (p < 0.001). At low dose levels, the dynamic arc technique irradiates less healthy tissue than the other techniques (p {<=} 0.001). Both dynamic arcs and IMRS provide increased ability to conform to the AVM, with IMRS showing greater ability to control dose at the periphery.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Quantifying element incorporation in multispecies biofilms using nanoscale secondary ion mass spectrometry image analysis

Elucidating nutrient exchange in microbial communities is an important step in understanding the relationships between microbial systems and global biogeochemical cycles, but these communities are complex and the interspecies interactions that occur within them are not well understood. Phototrophic consortia are useful and relevant experimental systems to investigate such interactions as they are not only prevalent in the environment, but some are cultivable in vitro and amenable to controlled scientific experimentation. Nanoscale secondary ion mass spectrometry (NanoSIMS) is a powerful, high spatial resolution tool capable of visualizing the metabolic activities of single cells within a biofilm, but quantitative analysis of the resulting data has typically been a manual process, resulting in a task that is both laborious and susceptible to human error. In this work, the authors describe the creation and application of a semiautomated image-processing pipeline that can analyze NanoSIMS-generated data, applied to phototrophic biofilms as an example. The tool employs an image analysis process, which includes both elemental and morphological segmentation, producing a final segmented image that allows for discrimination between autotrophic and heterotrophic biomass, the detection of individual cyanobacterial filaments and heterotrophic cells, the quantification of isotopic incorporation of individual heterotrophic cells, and calculation of relevant population statistics. The authors demonstrate the functionality of the tool by using it to analyze the uptake of 15 N provided as either nitrate or ammonium through the unicyanobacterial consortium UCC-O and imaged via NanoSIMS. The authors found that the degree of 15N incorporation by individual cells was highly variable when labeled with 15 NH 4 + , but much more even when biofilms were labeled with 15 NO 3 – . In the 15 NH 4 + -amended biofilms, the heterotrophic distribution of 15 N incorporation was highly skewed, with a large population showing moderate 15 N incorporation and a small number of organisms displaying very high 15 N uptake. The results showed that analysis of NanoSIMS data can be performed in a way that allows for quantitation of the elemental uptake of individual cells, a technique necessary for advancing research into the metabolic networks that exist within biofilms with statistical analyses that are supported by automated, user-friendly processes.

59 BASIC BIOLOGICAL SCIENCES↗

The utility of diffusion-weighted imaging in improving the sensitivity of LI-RADS classification of small hepatic observations suspected of malignancy

Purpose: We investigated the added value of diffusion-weighted imaging (DWI)/apparent diffusion coefficient (ADC) in the categorization of small hepatic observation (≤ 20 mm) detected in patients with chronic liver disease in reference to LI-RADS (liver imaging reporting and data system) classification system. Methods: We prospectively evaluated 165 patients with chronic liver disease with small hepatic observations (≤ 20 mm) which were previously categorized as LI-RADS grade 3–5 on dynamic contrast-enhanced CT (DCE-CT). All patients were submitted to a functional MRI including DCE and DWI. Using LI-RADS v2017, two radiologists independently evaluated the observations and assigned a LI-RADS category to each observation using DCE-MRI alone and combined DCE-MRI and DWI/ADC. In the combined technique, the radiologists assigned a LI-RADS category based on a modified LI-RADS criteria in which restricted diffusion on DWI was considered a major feature of HCC. We evaluated the inter-reader agreement with Kappa statistics and compared the diagnostic performance of the LI-RADS with two imaging techniques by Fisher’s exact test using histopathology as the reference standard. Results: Combined technique in LI-RADS yielded better sensitivities (reader 1, 97% [65/67]; reader 2, 95.5% [64/67]) for HCC diagnosis than DCE-MRI alone (reader 1, 80.6% [54/67], p = 0.005; reader 2, 83.6% [56/67], p = 0.04). The specificities were insignificantly lower in combined technique (reader 1, 88.4% [107/121]; reader 2, 77.7% [94/121]) than in DCE-MRI alone (reader 1, 90.9% [110/121], p = 0.67; reader 2, 79.3% [96/121], p = 0.88). The inter-reader agreement of the LI-RADS scores between combined technique and DCE-MRI was good (κ = 0.765). Conclusion: The use of DWI/ADC as an additional major criterion, improved the sensitivity of LI-RADS in the diagnosis of HCC while keeping high specificity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Statistical Characterization and Process Control for Improved Growth of La2−xSrxCuO4 Films

We have used combinatorial molecular beam epitaxy (COMBE) technique to deposit thin cuprate films with continuous spread in chemical composition, as well as nominally uniform films. We have patterned them into linear pixel arrays and measured the transport properties of each pixel. We applied detailed statistical analysis to differentiate between various possible sources of random pixel-to-pixel variations, and utilized this knowledge to considerably tighten the process parameters and significantly reduce such variations. The density and quality of data points is high enough to allow detection of quantum phase transitions induced by tuning the chemical composition.

36 MATERIALS SCIENCE↗

Determining the significance of associations between two series of discrete events: bootstrap methods

We review and develop techniques to determine associations between series of discrete events. The bootstrap, a nonparametric statistical method, allows the determination of the significance of associations with minimal assumptions about the underlying processes. We find the key requirement for this method: one of the series must be widely spaced in time to guarantee the theoretical applicability of the bootstrap. If this condition is met, the calculated significance passes a reasonableness test. We conclude with some potential future extensions and caveats on the applicability of these methods. The techniques presented have been implemented in a Python-based software toolkit.

97 MATHEMATICS AND COMPUTING↗

WE-EF-BRA-11: Precision Partial-Tumor Irradiation of Dorsal Rodent Mammary Tumors

Purpose: To introduce a pre-clinical treatment technique on a micro-irradiator to treat specific volumes of dorsal mammary tumors in BALB/c mice while sparing lungs and spine. This technique facilitates pre-clinical investigation of tumor response to sub-optimal radiation treatments in which a portion of the tumor is unirradiated, known as a “marginal miss”. In-vitro data suggests that partial tumor radiations trigger a more aggressive phenotype in non-irradiated, regional tumor cells via bystander effects. As the lung tissue is spared, the impact of marginal miss on the development of pulmonary metastasis may be assessed. Methods: End to end test was performed on three BALB/c mice as proof of concept for larger studies. 1Gy was delivered on the micro-irradiator employing previously unexplored lateral parallel-opposed diamond and/or triangle-shaped beams. The margins of the treatment beam were defined using a combination of tumor palpation, barium fiducial markers, and real-time fluoroscopic images. The dose distribution was independently verified with kilovoltage beam Monte Carlo dose calculations with 7% statistical uncertainty and double exposure images. As a final step, the technique was used in a larger pre-clinical study (15Gy, 36 BALB/c mice) and lung metastasis in response to tumor irradiation of 100%, 50% and 0% was quantified. Results: For the Monte-Carlo dose calculations, the dose volume histograms established a maximum dose within the un-irradiated and radiated portions of the mammary tumor of 0.3Gy and 1.5Gy respectively, with a sharp gradient at the boundary. 100% of the lung volume received less than 0.5Gy. This technique proved suitable for a pre-clinical marginal miss study with 50% more lung metastases in partially-radiated mouse models compared to completely. Conclusion: We have developed a novel treatment technique for partial or full irradiation of dorsal mammary tumors incorporating lung sparing.The technique will be useful for exploring the phenomena of aggressive tumor phenotype that may arise from miss-irradiation.

60 APPLIED LIFE SCIENCES↗

Validity of the line-pair bar-pattern method in the measurement of the modulation transfer function (MTF) in megavoltage imaging

The measurement of the modulation transfer function (MTF) of an imaging device is a common requirement in evaluating radiographic detector performance. Such measurements are considered mandatory in detector development research, and may also be carried out as part of routine quality assurance (QA) checks of image quality. Traditionally, MTF measurement has been performed by imaging either a narrow slit or a sharp edge in order to generate a line spread function, whose Fourier transform provides the MTF on a near-continuous frequency domain. Much less commonly employed is the method of square-wave line-pair modulations, in which the modulation response to bar resolution targets contained in a bar pattern is used to estimate the MTF at discrete spatial frequencies. While the slit and edge methods offer advantages of accuracy and a well-known standardized protocol for measurement based on several decades of development, their major limitation is the difficult and time-consuming experimental setup that is necessary to ensure accurate measurements. On the other hand, the bar pattern offers the advantage of a quick, simple, and easy measurement without the need for a complex experimental setup, with the main disadvantages of the technique being a pseudo-normalization that may lead to an overestimated MTF, and corrections for removing higher-order frequency harmonics that require interpolating between discrete spatial frequencies. Therefore, bar patterns are traditionally used for qualitative imaging applications like detector QA in terms of relative and arbitrarily defined spatial resolution metrics, while slit and edge methods are preferred for quantitative MTF measurements. Compared to diagnostic x rays, MTF measurements using megavoltage x rays are further complicated by low x-ray attenuation and excessive Compton scattering. In this work, a method to measure the MTF of megavoltage x-ray detectors based on imaging square-wave line pairs with improved near-zero-frequency normalization was developed as an adaptation to previously reported methods. Monte Carlo simulations were used to identify an improved normalization condition with which the accuracy of the MTF determined from line-pair modulations could be enhanced considerably compared to previously used techniques. Slit, edge, and bar-pattern measurements were performed to obtain the MTF of commercial megavoltage imaging devices including portal film and electronic portal imaging devices. A comparison of the MTF measurements from the three techniques was used to ascertain the validity of the proposed bar-pattern method for accurate and reliable measurement of MTF for megavoltage imagers. Statistical analyses revealed no significant differences between the bar-pattern method and the standard slit and edge techniques, indicating very good agreement (mean difference within {+-}3%). These results indicated the potential for line-pair bar patterns to be used more effectively than in the past for traditional QA imaging as well as for quantitative MTF measurement in detector development research.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

On physical interpretation of two dimensional time-correlations regarding time delay velocities and eddy shaping

Time delay estimation (TDE) techniques are frequently used to estimate the flow velocity from fluctuating measurements. Tilted structures carried by the flow lead to misinterpretation of the time delays in terms of velocity direction and amplitude. It affects TDE measurements from probes, and is also intrinsically important for beam emission spectroscopy and gas puff imaging measurements. Local eddy shapes estimated from 2D fluctuating field are necessary to gain a more accurate flow estimate from TDE, as illustrated by Langmuir probe array measurements. A least square regression approach is proposed to estimate both flow field and shaping parameters. The technique is applied to a test case built from numerical simulation of interchange fluctuations. The local eddy shape does not only provide corrections for the velocity field but also quantitative information about the statistical interaction mechanisms between local eddies and E Multiplication-Sign B flow shear. The technique is then tested on gaz puff imaging data collected at the edge of EAST tokamak plasmas. It is shown that poloidal asymmetries of the fluctuation fields-velocity and eddy shape-are consistent at least qualitatively with a ballooning type of turbulence immersed in a radially sheared equilibrium flow.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A Measurement of Gravitational Lensing of the Cosmic Microwave Background by Galaxy Clusters Using Data from the South Pole Telescope

Clusters of galaxies are expected to gravitationally lens the cosmic microwave background (CMB) and thereby generate a distinct signal in the CMB on arcminute scales. Measurements of this effect can be used to constrain the masses of galaxy clusters with CMB data alone. Here we present a measurement of lensing of the CMB by galaxy clusters using data from the South Pole Telescope (SPT). We also develop a maximum likelihood approach to extract the CMB cluster lensing signal and validate the method on mock data. We quantify the effects on our analysis of several potential sources of systematic error and find that they generally act to reduce the best-fit cluster mass. It is estimated that this bias to lower cluster mass is roughly 0.85σ in units of the statistical error bar, although this estimate should be viewed as an upper limit. Furthermore, we apply our maximum likelihood technique to 513 clusters selected via their Sunyaev–Zeldovich (SZ) signatures in SPT data, and rule out the null hypothesis of no lensing at 3.1σ. The lensing-derived mass estimate for the full cluster sample is consistent with that inferred from the SZ flux: M 200,lens = 0.83 +0.38 -0.37 M 200,SZ (68% C.L., statistical error only).

79 ASTRONOMY AND ASTROPHYSICS↗