Rotational flexural strength of cylindrical brittle specimens

Conventional static flexural strength testing of brittle cylindrical rods only subjects a small fraction of the entire specimen's area or volume to the maximum tensile stress. Thus, a nonconservative measured strength likely results since most flaws on the surface or in the bulk are not subjected to a sufficiently high tensile stress that can cause fracture. Here, to mitigate this, a rotational flexural tester and corresponding test method were developed whereby rotation and monotonically increasing three-point flexure were superimposed to investigate fracture response of solid glass cylinders. This combination of rotation and flexure subjects more area and volume of a cylindrical test specimen to tensile stress than a standard static (nonrotating) flexural test. As anticipated, failure stresses were lower for the rotational flexural test. Expressions for effective area and volume are provided for rotating solid rods and tubes subjected to three-point, four-point, uniform, and uniformly distributed load bending configurations.

36 MATERIALS SCIENCE↗

Impact and residual fatigue behavior of ARALL and AS6/5245 composite materials

Aramide fiber reinforced aluminum laminates (ARALL) represent a cross between resin matrix composites and metals. The purpose of this study was to evaluate the impact sensitivity of this concept. Two types of ARALL (7075 aluminum prestrained and 2024 aluminum not prestrained) were tested through static indentation and the results compared to sheet 2024-T3 and 7075-T6 aluminum alloys. A state-of-the-art composite (AS6/5245) was also tested and compared to the ARALL. Further, the two types of ARALL material and the composite were dynamically impacted at two energy levels and fatigue tested to determine residual fatigue strength. Both forms of the ARALL material had worse impact resistance than monolithic sheet aluminum. The ARALL material made with 2024-T3 aluminum had better impact resistance than did the laminates made with 7075-T6 aluminum. The ARALL materials are at least equal to the composite material in impact damage resistance and are better for impact detection. The composite material has higher residual fatigue strength after impact than the ARALL material and is 25 percent lighter. The prestraining of the ARALL greatly reduces the fatigue growth of impact damage.

Johnson, W. S.↗

Early Results from a Broad Compatibility Study of Various Materials with Ionic Silver Biocide

Ionic silver is baselined for microbial control in spacecraft potable water systems forfuture exploration missions, but materials compatibility analysis is required to evaluate thepassive depletion of ionic silver concentration onto wetted material surfaces over time.Various articles concerning such testing have been published that examine interactions withwater containing ionic silver biocide, but most tests have focused on only a couple ofmaterials each and comparing results of different evaluations to one another has provedchallenging.This paper reports the first results from static exposure testing of a large arrayof material coupons to a 400 parts per billion (ppb) aqueous silver fluoride (AgF) solution,using a surface to volume ratio of approximately 2 cm-1. The test is designed in two mainstages. Stage 1 is a one-week screening to evaluate silver uptake. Materials that performmodestly to well after that week are promoted to Stage 2, which is a longer test with periodicsampling to examine the silver uptake rates over time; these samples are evaluated for otherwater quality parameters in addition to the remaining silver concentration. In a tangentialinvestigation, select materials that take up some silver in Stage 1 may be “aged” by repeatingthe Stage 1 test to determine whether repeated exposure reduces silver uptake rate, andsuccessfully aged materials may then continue to Stage 2 testing. The materials under testinclude metallic and polymeric materials with various surface finishes, treatments, andcoatings, as well as select other materials historically used in spacecraft water systems. Thistest began in August 2019, and thus only includes early results; future follow-on papers willinclude additional results as the test progresses. The ultimate goal builds a broad, easilycomparable data set that can be used to guide material selections for silver biocide-compatible spacecraft water system design.

Silver Biocide↗

An experimental investigation of dynamic ground effect

A 60-degree delta wing, an F-106B, and an XB-70 model with and without flap deflections were tested in static and dynamic ground effect in the 36-by 51-inch subsonic wind tunnel at the University of Kansas. Dynamic ground effect was measured with movable sting support. For flow visualization, a tufted wire grid was mounted on the movable sting behind the model. Test results showed that lift and drag increments in dynamic ground effect were always lower than static values. Effect of the trailing edge flap deflections on lift increments was slight. The fuselage reduced the lift increments at a given ground height. From flow visualization under static conditions, the vortex core was seen to enlarge as the ground was approached.

Lee, Pai Hung↗

Experimental investigation of dynamic ground effect

A 60-degree delta wing, an F-106B, and an XB-70 model with and without flap deflections were tested in static and dynamic ground effect in the 36-by-51-inch subsonic wind tunnel at the University of Kansas. Dynamic ground effect was measured with movable sting support. For flow visualization, a tufted wire grid was mounted on the movable sting behind the model. Test results showed that lift and drag increments in dynamic ground effect were always lower than static values. Effect of the trailing edge flap deflections on lift increments was slight. The fuselage reduced the lift increments at a given ground height. From flow visualization under static conditions, the vortex core was seen to enlarge as the ground was approached.

Lee, Pai-Hung↗

Crashworthy Evaluation of a 1/5-Scale Model Composite Fuselage Concept

A 1/5-scale model composite fuselage concept for light aircraft and rotorcraft has been developed to satisfy structural and flight loads requirements and to satisfy design goals for improved crashworthiness. The 1/5-scale model fuselage consists of a relatively rigid upper section which forms the passenger cabin, a stiff structural floor, and an energy absorbing subfloor which is designed to limit impact forces during a crash event. The focus of the present paper is to describe the crashworthy evaluation of the fuselage concept through impact testing and finite element simulation using the nonlinear, explicit transient dynamic code, MSC/DYTRAN. The energy absorption behavior of two different subfloor configurations was determined through quasi-static crushing tests. For the dynamic evaluation, each subfloor configuration was incorporated into a 1/5-scale model fuselage section, which was impacted at 31 ft/s vertical velocity onto a rigid surface. The experimental data demonstrate that the fuselage section with a foam-filled subfloor configuration satisfied the impact design requirement. In addition, the fuselage section maintained excellent energy absorption behavior for a 31 ft/s vertical drop test with a 15 deg-roll impact attitude. Good correlation was obtained between the experimental data and analytical results for both impact conditions.

Jackson, Karen E.↗

An experimental investigation of dynamic ground effect

Sixty degree delta wing, F-106B, and XB-70 models with and without flap deflections were tested in static and dynamic ground effect in the 36 by 51 inch subsonic wind tunnel at the University of Kansas. Dynamic ground effect was measured with movable sting support. For flow visualization, a tufted wire grid was mounted on the movable sting behind the model. Tests results showed that the lift and drag increments in dynamic ground effect were always lower than the static values. Effect of the trailing-edge flap deflections on lift increments was slight. The fuselage reduced the lift increments at a given ground height. From flow visualization under static conditions, the vortex core was seen to enlarge as the ground approached.

Lee, Pai Hung↗

CARS temperature measurements in a hypersonic propulsion test facility

Static-temperature measurements performed in a reacting vitiated air-hydrogen Mach-2 flow in a duct in Test Cell 2 at NASA LaRC by using a coherent anti-Stokes Raman spectroscopy (CARS) system are discussed. The hypersonic propulsion Test Cell 2 hardware is outlined with emphasis on optical access ports and safety features in the design of the Test Cell. Such design considerations as vibration, noise, contamination from flow field or atmospheric-borne dust, unwanted laser- and electrically-induced combustion, and movement of the sampling volume in the flow are presented. The CARS system is described, and focus is placed on the principle and components of system-to-monochromator signal coupling. Contour plots of scramjet combustor static temperature in a reacting-flow region are presented for three stations, and it is noted that the measurements reveal such features in the flow as maximum temperature near the model wall in the region of the injector footprint.

Jarrett, O., Jr.↗

The Impact Response of Carbon/Epoxy Laminates (Center Director's Discretionary Fund, Project No. 94-13)

Low velocity dropweight impact tests were conducted on carbon/epoxy laminates under various boundary conditions. The composite plates were 8-ply (+45,0,-45,90)s laminates supported in a clamped-clamped/free-free configuration with varying amounts of in-plane load, N(sub x), applied. Specimens were impacted at energies of 3.4, 4.5, and 6 Joules (2.5, 3.3, and 4.4 ft-lb). The amount of damage induced into the specimen was evaluated using instrumented impact techniques, x-ray inspection, and cross-sectional photomicroscopy. Some static identation tests were performed to examine if the impact events utilized in this study were of a quasi-static nature and also to gain insight into the shape of the deflected surface at various impact load combinations. Load-displacement curves from these tests were compared to those of the impact tests, as was damage determined from x-ray inspection. The finite element technique was used to model the impact event and determine the stress field within the laminae. Results showed that for a given impact energy level, more damage was induced into the specimen as the external in-plane load, N(sub x), was increased. The majority of damage observed consisted of back face splitting of the matrix parallel to the fibers in that ply, associated with delaminations emanating from these splits. The analysis showed qualitatively the results of impact conditions on maximum load of impact, maximum transverse deflection, and first failure mode and location.

Nettles, A. T.↗

Simulated hail impact testing of photovoltaic solar panels

Techniques used to simulate and study the effect of hail on photovoltaic solar panels are described. Simulated hail stones (frozen ice spheres projected at terminal velocity) or steel balls were applied by air guns, gravity drop, or static loading. Tests with simulated hail and steel balls yielded different results. The impact strength of 10 commercially available flat-plate photovoltaic modules was tested. It was found that none of the six panel designs incorporating clear potting silicone material as the outermost layer remained undamaged by 1-in. simulated hailstones, while a photovoltaic module equipped with a 0.188-in.-thick acrylic cover sheet would be able to withstand the impact of a 2-in.-diameter hailstone.

Moore, D.↗

Reduction of fan noise in an anechoic chamber by reducing chamber wall induced inlet flow disturbances

The difference between the flight and ground static noise of turbofan engines presents a significant problem in engine noise testing. The additional noise for static testing has been attributed to inlet flow disturbances or turbulence interacting with the fan rotor. In an attempt to determine a possible source of inflow disturbances entering fans tested in the Lewis Research Center anechoic chamber, the inflow field was studied using potential flow analysis. These potential flow calculations indicated that there was substantial flow over the wall directly behind the fan inlet that could produce significant inflow disturbances. Fan noise tests were run with various extensions added to the fan inlet to move the inlet away from this backwall and thereby reduce the inlet flow disturbances. Significant noise reductions were observed with increased inlet length. Over 5 db reduction of the blade passage tone sound power level was observed between the shortest and longest inlets at 90% fan speed and the first overtone was reduced 9 db. High frequency broadband noise was also reduced.

Dittmar, J. H.↗

On Restructurable Control System Theory

The state of stochastic system and control theory as it impacts restructurable control issues is addressed. The multivariable characteristics of the control problem are addressed. The failure detection/identification problem is discussed as a multi-hypothesis testing problem. Control strategy reconfiguration, static multivariable controls, static failure hypothesis testing, dynamic multivariable controls, fault-tolerant control theory, dynamic hypothesis testing, generalized likelihood ratio (GLR) methods, and adaptive control are discussed.

Athans, M.↗

Experimental Investigation of Plume-Induced Flow Separation on the National Launch System 1 1/2-Stage Launch Vehicle

An experimental investigation of plume-induced flow separation on the National Launch System (NLS) 1 1/2-stage launch vehicle was done. This investigation resulted from concerns raised about the flow separation that was encountered on the Saturn 5. A large similarity exists between configurations and nominal trajectories. The study involved the use of solid plume simulators to simulate the base pressure encountered by the vehicle due to engine exhaust plumes at predetermined critical Mach numbers based on Saturn 5 flight plume effects. The solid plume was varied in location, resulting in a parametric study of base pressure effects on flow separation. In addition to the parametric study of arbitrary plume locations, the base pressure resulting from the nominal trajectory was tested. This analysis was accomplished through two wind tunnel tests run at NASA Marshall Space Flight Center's 14 x 14-inch Trisonic Wind Tunnel during 1992. The two tests were a static stability and a pressure test each using a 0.004-scale NLS 1 1/2-stage model. This study verified that flow separation is present at Mach 2.74 and 3.48 for predicted flight base pressures at nominal or higher levels. The flow separation at the predicted base pressure is only minor and should not be of great concern. It is not of the magnitude of the flow separation that was experienced on the Saturn 5. If the base pressure exceeds these nominal conditions, the flow separation can drastically increase, and is of concern.

Springer, A.↗

An Interim Set of TNT Curves for LOX/LNG Explosions

Space launch companies are actively developing, or in some cases have already developed, new vehicles that use large quantities of liquid oxygen (LOX) and liquid natural gas (LNG) propellants. This propellant mixture currently lacks sound/verified explosive safety standards for use in explosive siting and flight safety analysis. In the U.S., multiple government and commercial organizations have conducted limited testing, or are preparing to conduct tests, intended to provide a sound technical basis for LOX/LNG explosive standards applicable to space launch vehicle ground and flight operations. The limited testing and analysis conducted so far indicates the potential to produce extremely energetic explosions due to the miscibility of LOX/LNG (methane), a unique feature relative to previously used propellant mixtures such as hydrogen/oxygen or kerosene/oxygen. MOX is a homogenous mixture of methane and oxygen that is possible because of methane’s 100% miscibility in LOX. Preliminary testing by N2L, Inc. described in this paper shows that it is possible to form MOX with a variety of mixing methods, and that MOX is a sensitive high explosive capable of producing overpressures greater than comparable masses of C-4. The limited amount and quality of large-scale LOX/LNG explosive test data, and the potential formation of high-explosive MOX, create significant unknowns in the determination of hazard areas (cleared of the public) for ground operations (such as a static fire test) and flights of launch vehicles with LOX/LNG propellant. This paper will review the methods used by NASA to develop and validate the LOX/LH2 blast model using large-scale explosive test programs such as Project PYRO, the Hydrogen-Oxygen Vertical Impact (HOVI), and the Large-Scale Hydrogen-Oxygen Explosion (LSHOE) tests. This paper will describe how the same process was used to prepare an interim LOX/LNG blast model that applies to various LV failure scenarios and conservatively accounts for potential MOX formation. This paper also summarizes past and future testing and modeling efforts funded by a consortium of NASA, the US Federal Aviation Administration (FAA), and the US Space Force (USSF). These test programs should be concluded within the next 3 years and are intended to provide empirical data for model verification and validation.

Liquid Oxygen↗

An Interim Set of TNT Curves for LOX/LNG Explosions

Space launch companies are actively developing, or in some cases have already developed, new vehicles that use large quantities of liquid oxygen (LOX) and liquid natural gas (LNG) propellants. This propellant mixture currently lacks sound/verified LOX/LNG explosive safety standards for use in explosive siting and flight safety analysis. In the U.S., multiple government and commercial organizations have conducted limited testing, or are preparing to conduct tests, intended to provide a sound technical basis for explosive standards applicable to space launch vehicle ground and flight operations. The limited testing and analysis conducted so far indicates the potential to produce extremely energetic explosions due to the miscibility of LOX/LNG (methane), a unique feature relative to previously used propellant mixtures such as hydrogen/oxygen or kerosene/oxygen. MOX is a homogenous mixture of methane and oxygen that is possible because of methane’s 100% miscibility in LOX. Preliminary testing by N2L, Inc. described in this paper shows that it is possible to form MOX with a variety of mixing methods, and that MOX is a sensitive high explosive capable of producing overpressures greater than comparable masses of C-4. The limited amount and quality of large-scale LOX/LNG explosive test data, and the potential formation of high-explosive MOX, create significant unknowns in the determination of hazard areas (cleared of the public) for ground operations (such as a static fire test) and flights of launch vehicles with LOX/LNG propellant. This paper will review the methods used by NASA to develop and validate the LOX/LH2 blast model using large-scale explosive test programs such as Project PYRO, the Hydrogen-Oxygen Vertical Impact (HOVI), and the Large-Scale Hydrogen-Oxygen Explosion (LSHOE) tests. This paper will describe how the same process was used to prepare an interim LOX/LNG blast model that applies to various LV failure scenarios and conservatively accounts for potential MOX formation. This paper also summarizes past and future testing and modeling efforts funded by a consortium of NASA, the US Federal Aviation Administration (FAA), and the US Space Force (USSF). These test programs should be concluded within the next 3 years and are intended to provide empirical data for model verification and validation.

Liquid Oxygen↗

Large-scale static investigation of circulation-control-wing concepts applied to upper surface-blowing aircraft

The use of a circulation control to deflect turbofan engine thrust beyond 90 deg. has been proven in full-scale static ground tests of the circulation-control-wing/upper-surface-blowing (CCW/USB) concept. This powered high-lift system employs a circular, blown trailing edge to replace the USB mechanical flaps to entrain engine-exhaust flow, and to obtain both a vertical-thrust component and an augmented circulation lift for short takeoff and landing (STOL) applications. Previous tests (Phase 1), done in 1982, of a basic configuration installed on the Quiet Short Haul Research Aircraft confirmed these CCW/USB systems capabilities. A second phase (Phase 2) of full-scale, static, thrust-deflection investigations has reconfirmed the ability to deflect engine thrust from 40 to 102 deg., depending on thrust level. Five new configurations were evaluated and performance improvements noted for those configurations with larger blown span, fences or favorable engine interactions, smaller slot height, and larger radii with less than 180 deg. of CCW surface arc. In general, a 90 deg. circular arc with a smaller slot height provided the best performance, demonstrating that adequate thrust turning can be produced by a trailing-edge shape which may have minimal cruise-performance penalty. Thrust deflections were achieved at considerably lower blowing momentum than was required for the baseline case of Phase 1. Improved performance and versatility were thus confirmed for the CCW/USB system applied to STOL aircraft, where the potential for developing a non-moving-parts pneumatic thrust deflector to rapidly vary horizontal force from thrust to drag, while maintaining constant vertical force, appears quite promising. The conversion from high-lift to lower-drag cruise mode by merely terminating the blowing provides an effective STOL aircraft system.

Shovlin, M. D.↗

Report on Year-4 of Water NSTF Matrix Testing: Facility Maintenance and Accident Testing

Under support from the Department of Energy (DOE) and the Office of Advanced Reactor Technologies (ART), a large-scale test facility has been constructed at Argonne National Laboratory to generate NQA-1 qualified validation data for passive decay heat removal systems in advanced reactors. The Natural convection Shutdown heat removal Test Facility (NSTF) reflects key features of a ½ scale, water-based, Reactor Cavity Cooling System (RCCS) and is intended to study the behavior, bound performance, and ultimately guide design decisions for passive decay heat removal systems for advanced reactors. In addition to the experimental activities detailed in this report, a supportive computational modeling effort is on-going which has been demonstrated to significantly strengthen the experimental program while also improving accuracy of the computer models. Together these create a mutually beneficial relationship integral to meeting the overall program objective of examining the heat removal performance of the RCCS concept. This report serves as a summary of maintenance and experimental activities during the program’s fourth year of water-based operation. A planned six-month maintenance period began in August 2021, during which major inspections, repairs, cleaning, and installation of new instrumentation and data acquisition hardware were conducted. Most significantly, two heaters that faulted during Year-3 were repaired, allowing the facility to resume use of the full heated section area and full range of available electric power. The remainder of the year consisted of eight months of test operations, during which the facility logged 211 hours of active heating across one bake-out (following the maintenance period) and seven matrix tests; five classifieds as Accepted per NQA-1, one as Trending, and one as Failed. Testing began by performing two repeat cases to confirm expected facility response and behavior during both single- and two-phase flow conditions, ensuring no changes were introduced during the maintenance period that might have altered the thermal-hydraulic characteristics of the facility. In continuation of the power parametric series initiated in previous years, a high-power test case was then performed examining heat removal performance at a decay heat load equivalent to 2.4 MWt, full-scale, a level exceeding maximum design targets. Additional testing then introduced various blockage scenarios along the network piping, examining the effects of partial and complete blockages of the flow paths on the system behavior and heat removal performance. A study of static boiling tests directed at understanding the geysering two-phase instability was also conducted. The loop was filled only to the bottom of the tank outlet, creating an open loop configuration that prevents any natural circulation flow from occurring, and the heaters were powered on until the facility reached saturation conditions. Following, a series of quasi-steady-state conditions were introduced by adjusting the inventory level in the adiabatic chimney piping at decreasingly lower elevations above the heated region. A strong correlation of geysering characteristics and loop level was observed, with flow and temperature excursions decreasing in intensity, but increasing in frequency, as the fill were reduced to lower elevations along the chimney piping. Once the level fell very low in the chimney, at points near the top of the heated section, the system reached a stable state of continuous boiling without any occurrence of geysering eruptions. A final significant testing accomplishment this year was successful completion of an “accident scenario” test, whose operating conditions were based on a prototypic decay heat curve provided by Framatome and scaled for the NSTF. This test began by establishing steady-state, single-phase “normal operation” conditions, before simulating an accident trip where the availability of active cooling systems was lost. Loop temperatures gradually increased until reaching saturation and subsequent two-phase boiling flow. Over the course of an extended operational period along the defined decay heat curve, steam boil-off caused gradual but continued depletion of liquid inventory until reaching a critically low level causing flow stagnation and cessation of natural circulation heat removal. At this point, after nearly 72 hours of continuous operation, a cold refill was performed to replenish the system inventory and allow the facility to re-establish closed loop natural circulation flow and return to a safe operational state.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗