Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “specific energy consumption”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 865 records · Page 48

Emerging Technologies Review: Water Reuse Systems for Cooling Tower Applications

This report explores the concept of water reuse systems for cooling tower water makeup, specifically focusing on the use of alternative water sources, and the viability of these systems for Air Force installations and operations. Cooling is a critical requirement for DAF operations, and alternative water supplies that enable cooling tower use during a disruption of utility-supplied water increase Air Force resilience. The components of a water reuse system for cooling towers include alternative water supplies, storage, treatment, and distribution in addition to the cooling tower itself. Alternative water sources are not derived from fresh surface water or groundwater and can provide a redundant water supply to utility supply or to fresh water produced on site.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Chapter 17: Residential Behavior Evaluation Protocol. The Uniform Methods Project: Methods for Determining Energy Efficiency Savings for Specific Measures, September 2011 - August 2020

This document has been updated in August 2020. This document was developed for the U.S. Department of Energy Uniform Methods Project (UMP). The UMP provides model protocols for determining energy and demand savings that result from specific energy-efficiency measures implemented through state and utility programs. In most cases, the measure protocols are based on a particular option identified by the International Performance Verification and Measurement Protocol; however, this work provides a more detailed approach to implementing that option. Each chapter is written by technical experts in collaboration with their peers, reviewed by industry experts, and subject to public review and comment. The protocols are updated on an as-needed basis. The UMP protocols can be used by utilities, program administrators, public utility commissions,evaluators, and other stakeholders for both program planning and evaluation. To learn more about the UMP, visit the website, https://energy.gov/eere/about-us/ump-home, or download the UMP introduction document at http://www.nrel.gov/docs/fy17osti/68557.pdf.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

HVAC System Performance for Energy Codes (Technical Brief)

The prescriptive path is likely the most widely used approach for commercial code compliance in the United States. Though easy to implement, the prescriptive approach does not discriminate between high-performing and poorly performing heating, ventilation, air conditioning (HVAC) system configurations that are both minimally compliant. To meet aggressive energy and carbon reduction goals, energy codes will need to transition from prescriptive to performance-based approaches, a transition that is riddled with several challenges. HVAC System Performance is a discipline performance path and provides a simpler solution to HVAC system evaluation compared to whole building performance, while keeping tradeoffs limited to specific building systems. The Total System Performance Ratio (TSPR) is a metric for evaluation of overall system efficiency instead of individual component efficiency, a solution that could also eventually facilitate the transition to a 100% performance-based code structure. TSPR is a ratio that compares the annual heating and cooling load of a building to the annual energy consumed by the building’s HVAC system. A web-based calculation tool has been developed for determining a building’s TSPR. Already incorporated into the 2018 Washington State Energy Code, this approach has also been evaluated by the ASHRAE Standard 90.1 Project Committee and has the potential to provide a comprehensive performance-based approach for HVAC system evaluation and analysis

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Working Fluid Characterization and Performance Assessment of Subcritical Organic Rankine Cycles Based on the Lee–Kesler Approach for Energy Recovery

Here, a generalized model using the Lee–Kesler approach based on the corresponding states principle is developed to assess the performance of subcritical Organic Rankine Cycles operating with different working fluids. Each fluid is characterized by five parameters: the acentric factor, critical temperature, critical pressure, molar mass, and the ideal-gas ratio of specific heats at the critical temperature. The model was developed using the compressibility factor modified version of the Benedict–Webb–Rubin equation proposed by Lee and Kesler and the enthalpy and entropy functions to calculate thermodynamic state properties. The model was validated by comparing the results calculated with the model and working fluid thermodynamic properties obtained with the CoolProp database. This comparison was conducted for 91 working fluids, obtaining a relative error below 5% for 88 out of the 91 fluids (∼97%). A generalized parametric study was conducted to determine the influence of the pinch point and each fluid parameter on the performance of Organic Rankine Cycle (ORC) systems. It was found that efficiency increases with critical temperature, ideal-gas ratio of specific heats at the critical temperature, and acentric factor, reaching up to 13%. The developed model enables the evaluation of ORC system performance for existing working fluids. It also allows the formulation and evaluation of new fluids to enhance the performance of the ORC while retrieving energy from any kind of source; and likewise, the methodology can be applied to other power generation cycles.

24 POWER TRANSMISSION AND DISTRIBUTION↗

How Does Home Energy Score Affect Home Value and Mortgage Performance?

Energy-efficient homes save their occupants money through lower energy bills. These savings might be capitalized into higher home sale prices. They also improve the household’s net cash flow, which might make households better able to pay mortgage debt. The U.S. Department of Energy (DOE)’s Home Energy Score (HES) assigns a 1-10 score to homes and estimates annual energy bills based on modeled energy consumption. In this paper we investigated the relationship between HES metrics and two housing market outcomes: home sale price and mortgage performance. We found that the relationship was only statistically significant in places with a mandatory HES assessment at the time of sale. Using a sample of 26,291 home sales that occurred after HES assessments, we found that a one-point increase in HES in these locations was associated with a 0.5% increase in sale price, and an increase in $100 of estimated annual energy bills was associated with a 0.4% decrease. This magnitude of effect is consistent with estimated magnitudes of home sale premiums for other green or energy-efficient home certifications in the literature. We also found that a one-point increase in HES was associated with a 5.5% reduction in the odds of a loan going 30 days delinquent if the loan originated after the assessment occurred. Similarly, we found that a $100 decrease in estimated annual energy bills was associated with a 2.3% decrease in the odds of a loan going delinquent if it originated after the assessment occurred. Our results suggest that HES provides a valuable signal for housing market transactions in specific situations.

Pigman, Margaret↗

Using non-invasive MEMS pressure sensors for measuring building envelope air leakage

Micro-electromechanical systems (MEMS)-based sensors have seen significant improvements in accuracy and cost over the past several years, and due to the need for altitude sensing in unmanned aerial vehicles and wearable technologies, absolute pressure sensors have shown the most dramatic improvements. This paper investigates applications of MEMS sensors in commercial buildings, including pairing two absolute pressure sensors to determine differential pressures between different locations in and around buildings. Differential pressure measurements are commonly made in commercial buildings for a number of applications, including static pressure measurements for variable-speed supply fan control, air balancing in hospitals, and for envelope and duct air leakage testing. This paper focuses specifically on envelope air-leakage testing applications of these sensors. The use of continuous pressure measurements in addition to one-time non-intrusive outdoor airflow measurements of rooftop packaged units is investigated. A comparison with standardized leakage testing indicated that continuous measurements with MEMS pressure-sensors were able to estimate envelope leakage to within 3–16% of the standardized test result. In addition, the magnitude and stability of differential pressure differences that can be resolved with absolute pressure sensors are also investigated in the laboratory and the field. Results show that the sensors can be effectively used for pressures seen in low rise buildings with rooftop units.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Rooftop unit comparison calculator: a framework for comparing performance of rooftop units with building energy simulation

The applications of building energy simulation (BES) in designing heating, ventilation, and air conditioning (HVAC) systems are limited by the high costs of developing simulation models and the lack of references for determining the model parameters. This paper presents a software framework for selecting designs for rooftop unit HVAC (RTU) systems with BES. Specifically, this framework reduces the cost of using BES by automating the generation of EnergyPlus models. It also employs a systematic method for determining model parameters based on well-accepted datasets. We applied this framework in a comprehensive assessment of an advanced design of RTU systems in which 478 EnergyPlus models were developed without human involvement. The assessment reveals that replacing a constant-speed fan/coil with a multiple-speed fan/coil may not guarantee better overall performance. In conclusion, it also suggests the benefits of replacing furnace coils with heat pumps are subject to utility cost, weather conditions, and heating load profiles.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Integrating an Ensemble Reward System into an Off-Policy Reinforcement Learning Algorithm for the Economic Dispatch of Small Modular Reactor-Based Energy Systems

Nuclear Integrated Energy Systems (NIES) have emerged as a comprehensive solution for navigating the changing energy landscape. They combine nuclear power plants with renewable energy sources, storage systems, and smart grid technologies to optimize energy production, distribution, and consumption across sectors, improving efficiency, reliability, and sustainability while addressing challenges associated with variability. The integration of Small Modular Reactors (SMRs) in NIES offers significant benefits over traditional nuclear facilities, although transferring involves overcoming legal and operational barriers, particularly in economic dispatch. This study proposes a novel off-policy Reinforcement Learning (RL) approach with an ensemble reward system to optimize economic dispatch for nuclear-powered generation companies equipped with an SMR, demonstrating superior accuracy and efficiency when compared to conventional methods and emphasizing RL’s potential to improve NIES profitability and sustainability. Finally, the research attempts to demonstrate the viability of implementing the proposed integrated RL approach in spot energy markets to maximize profits for nuclear-driven generation companies, establishing NIES’ profitability over competitors that rely on fossil fuel-based generation units to meet baseload requirements.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

NFE-24-10417: Durability and Life-time Energy Performance Enhancement of Vapor Compression Systems

This project investigated the use of a Centrifugal Particle Separation (CPS) system to improve the durability and operational reliability of outdoor heat exchangers in vapor-compression based heating, ventilation, air conditioning, and refrigeration (HVACR) systems. The developed method introduced a novel dust and fouling mitigation approach by integrating an ambient air pre-cleaner that employs centrifugal forces to remove particulate matter from incoming air before it reaches the heat exchanger. By reducing the accumulation of dust and debris on coil surfaces, the CPS system aims to lower maintenance requirements and extend equipment lifespan. The project specifically involves coupling a centrifugal air pre-cleaner with a single-zone ductless mini-split system and evaluating its effectiveness in maintaining cleaner coil surfaces. Additionally, the study examined the impact of CPS integration on system energy performance. Through controlled experimental testing and performance monitoring, this work seeks to validate CPS-based air pre-cleaning as a practical, efficient solution for mitigating outdoor coil dust accumulation and fouling in both residential and commercial HVACR applications.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Characterizing Current THD’s Dependency on Solar Irradiance and Supraharmonics Profiling for a Grid-Tied Photovoltaic Power Plant

The rapidly increasing distributed energy resources (DERs) in power systems are now getting interconnected to set community grid structures, where power quality will be a major concern. The grid-to-grid (G2G) bidirectional power transfer among the distribution microgrid will not be considered commercially feasible unless the upstream harmonics are under the limits. The aggregation of such harmonics, measured as total harmonic distortion (THD), is feared to be beyond tolerable limits with the progression of rooftop grid-tied PV-like installations. Hence, this THD needs to be characterized with DER generation end variables. In this work, the photovoltaic (PV) DERs’ dependency on environment variables such as irradiance was profiled in the context of generating and injecting harmonics into the grid. A mathematical model of a grid-tied three-phase PV DER was developed as part of this correlation characterization, matching the fundamental unit structure of a 1.4 MW solar canopy located on the Florida International University (FIU) Miami campus. To determine the qualitative association with produced THD patterns, the model was evaluated with various irradiance settings. A real-time digital simulation (RTDS) platform was used to verify it. Following this confirmation, sets of data from power quality meters at the point of common coupling and FIU field sensors were utilized to validate further the correlation model. The results showed that the grid current’s THD exhibited a high correlation with the irradiance profile and its variation over time. The early morning and late afternoon periods of the day, associated with a low irradiance, constantly had higher harmonics generated from the PV DER. The midday THD was rather rational with partial shadings, hence a geolocation-dependent factor. These findings were verified by an RTDS and validated by real field data. In quantifying the THD injected by a single DER at a high-frequency (2–150 kHz) supraharmonics (SH) level, a 3% peak increment in magnitude was observed from the high-fixed to the low-fixed irradiance profile. The correlation characteristics depicted that the hybrid microgrid suffered from a daytime-dependent harmonic insertion from the grid-tied DER. This is a global problem unless specific measures are taken to mitigate the harmonics. The electrically notorious higher-frequency SH was found to increase proportionally. The G2G power transfer can be limited because of the higher THD in the early morning and late afternoon, which will also worsen because the numbers of grid-tied PV DERs (i.e., rooftop solar and industrial solar) are likely to increase rapidly soon. The community grid structure can thus have a controlled harmonics filtration setup purposefully designed to address the findings of this work, which also fall within the scope of our future research.

14 SOLAR ENERGY↗

Reinforcement learning for online adaptation of model predictive controllers: Application to a selective catalytic reduction unit

Here we present a novel application of reinforcement learning (RL) for online dynamic tuning of model predictive controllers (MPC). Applying a state-action-reward-state-action (SARSA) algorithm for temporal difference learning with a control-specific reward function improves the error tracking performance of a standard MPC formulation. The proposed RL approach is also readily adaptable to other MPCs, or entirely different control approaches. Practical details for the implementation of the RL-MPC algorithm are also presented. The proposed algorithm is applied to a case study of controlling nitrogen oxide (NO x ) emissions in an industrial selective catalytic reduction (SCR) unit, a control problem characterized by significant nonlinearity and time delay. Along with an RL-MPC formulation for NOx control, another MPC is proposed to mitigate ammonia slip and decrease ammonia consumption in the SCR. Results showing the efficacy of the RL-MPC for NO x control through learning and implementation on the nonlinear SCR dynamic model are presented.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Development of a Distribution Optimal Power Flow Federate for Open-Source OEDI-SI Platform

Increasing numbers of distributed generators in the electric power distribution networks require developing a control strategy to optimize solutions in real time. Linearized optimal distribution flow development has seen growth and acceptance in the distribution systems literature for efficiently modeling the \glspl{opf} for distribution systems. This paper examines the implementation and integration procedure for linearized optimal distribution flow federate to \gls{oedisi} platform. Specifically, we discuss i) the usage of the \gls{oedisi} platform, ii) obtaining a tractable solution using developed \gls{opf} federate, and iii) validation of solutions and bench-marking the \gls{oedisi} platform with developed \gls{opf} federate using OpenDSS. In brief, we demonstrate how a general linearized optimal distribution flow federate can be developed and integrated with a co-simulation environment to mimic real-world examples. The efficacy of the proposed method is demonstrated using the IEEE 123-bus test system under different scenarios to obtain a tractable solution and compare its results.

Sadnan, Rabayet↗

Methods Reduce Cost, Enhance Quality of Nanotubes

For all the challenges posed by the microgravity conditions of space, weight is actually one of the more significant problems NASA faces in the development of the next generation of U.S. space vehicles. For the Agency s Constellation Program, engineers at NASA centers are designing and testing new vessels as safe, practical, and cost-effective means of space travel following the eventual retirement of the space shuttle. Program components like the Orion Crew Exploration Vehicle, intended to carry astronauts to the International Space Station and the Moon, must be designed to specific weight requirements to manage fuel consumption and match launch rocket capabilities; Orion s gross liftoff weight target is about 63,789 pounds. Future space vehicles will require even greater attention to lightweight construction to help conserve fuel for long-range missions to Mars and beyond. In order to reduce spacecraft weight without sacrificing structural integrity, NASA is pursuing the development of materials that promise to revolutionize not only spacecraft construction, but also a host of potential applications on Earth. Single-walled carbon nanotubes are one material of particular interest. These tubular, single-layer carbon molecules - 100,000 of them braided together would be no thicker than a human hair - display a range of remarkable characteristics. Possessing greater tensile strength than steel at a fraction of the weight, the nanotubes are efficient heat conductors with metallic or semiconductor electrical properties depending on their diameter and chirality (the pattern of each nanotube s hexagonal lattice structure). All of these properties make the nanotubes an appealing material for spacecraft construction, with the potential for nanotube composites to reduce spacecraft weight by 50 percent or more. The nanotubes may also feature in a number of other space exploration applications, including life support, energy storage, and sensor technologies. NASA s various efforts with carbon nanotubes have made it a global leader in this field. Among the many examples are Johnson Space Center s Carbon Nanotube Project, which focuses on bulk nanotube production, purification, and application, and Goddard Space Flight Center s improved arc discharge method of nanotube production, developed under the direction of Jeannette Benavides (featured in Spinoff 2007 and 2008). While the Agency continues its own research, it partners with private companies to advance this unique technology for use on Earth as well as among the stars.

Source record↗

Sensitivity and Uncertainty Quantification of Transition Scenario Simulations

This report documents the first collective attempt at developing and applying capabilities to quantify uncertainties, assess parametric sensitivities, and optimize multiple parameters and metrics in fuel cycle simulations generated by the SA&I Campaign. To do this, external codes that were designed to perform sensitivity analysis and uncertainty quantification (SA&UQ) needed to be coupled to the SA&I Campaign’s nuclear fuel cycle simulators (NFCS). In FY20, two approaches were pursued: 1) coupling Cyclus to an ORNL-internal code called MOT (Metaheuristic Optimization Tool) and 2) coupling DYMOND to the opensource SA&UQ tool kit Dakota. The primary objective of having these NFCS/SA&UQ coupled capabilities is to better inform DOE-NE and other stakeholders on the results generated from the NFCS. For a given set of fuel cycle strategies, policies, and technology assumptions that make up a fuel cycle scenario, these NFCS have traditionally been used by the SA&I Campaign to provide quantitative answers in terms of year-by-year mass flows, infrastructure requirements, costs, etc. With these newly developed coupled capabilities, the SA&I Campaign can now efficiently simulate hundreds or thousands of these scenarios, sample large ranges of parameters and assumptions, and use the unique features of the SA&UQ tools to process the data. This enables providing answers with known and propagated uncertainties, determining the sensitivity of important metrics to different parameters and assumptions, quantifying how much fuel cycle and technology parameters impact each other, and producing optimized fuel cycle strategies for single and multiple variables. To demonstrate these new capabilities, the Cyclus/MOT was used to model several scenarios ranging from simple fleet retirements to transitions to advanced reactors. Specifically, for a transition scenario from LWRs to SFRs and advanced LWRs, uncertainty quantification, sensitivity analysis, and optimization studies were applied to cases involving single and multiple parameter (input) and single and multiple metric (output) variations. In addition, a similar transition scenario was modeled to demonstrate how to optimize the reprocessing capacity parameter to minimize two performance metrics while taking into account uncertainties from two other parameters. Lastly, a depletion module based on SCALE/ORIGEN was added in Cyclus to simulate the third scenario that was designed to quantify the impact of the modeling assumption that all LWR used nuclear fuel have the same burnup. The newly developed DYMOND/Dakota capability was also applied to a transition scenario from the existing fleet to small modular reactors and fast reactors. This particular scenario involves not only explicit isotopic depletion via ORIGEN-2, but also includes multirecycling and utilizing the criticality search feature to determine the fresh fuel composition of recycled fuel, a feature unique to the DYMOND NFCS. A large database of simulations were run with 4 main parameters that were sampled: start date of reprocessing, reprocessing capacity, energy demand growth rate, and advanced reactor share of the fleet. The 4 main metrics were uranium consumption, enrichment requirements, waste generation, and levelized cost of electricity using data from the Cost Basis Report. The demonstrated SA&UQ results include those that inform on how to choose parameters to avoid “failed” scenarios, Sobol’ indices that inform on the importance of various parameters individually and synergistically, and Analysis of Variance (ANOVA) studies that decompose parameter ranges into groups and informs on whether variations are statistically significant.

Feng, B.↗

Potential impact of work from home jobs on residential energy bills: A case study in phoenix, AZ, USA

Nearly one-third of U.S. households face challenges paying energy bills. During the day, many residents have routine access to cooled environments provided by others—employers, shopping centers, and other public buildings. The COVID-19 pandemic, however, has significantly shifted the cost burden of air conditioning in hot cities. Specifically, during the pandemic, many companies either laid off employees or put them in work-from-home (WFH) assignments. Large tech companies are already promoting WFH as a long-term option for their employees, even after the pandemic. This change in the nature of the workforce might reduce daily travel expenses for workers, but could also significantly increase residential energy bills, particularly during summer in very hot climates. Here, this study uses building energy simulations to quantify the potential residential energy bill penalties resulting from WFH for typical residences in Phoenix. Four building archetypes are used in this study to represent variations in building vintage, occupancy, and characteristics. The results show that, for some single-family residences in Phoenix, WFH can increase annual energy bills by more than $1100 (up to a 70% increase). The study also demonstrates that building performance enhancement retrofit measures have the potential to reduce this WFH energy bill penalty for the existing buildings substantially.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Geospatial Cost Comparison of CO2 Plume Geothermal (CPG) Power and Geologic CO2 Storage

CO 2 Plume Geothermal (CPG) power plants can use gigatonne-levels of CO 2 sequestration to generate electricity, but it is unknown if the resources that support low-cost CPG power align with the resources that support low-cost CO 2 sequestration. Here, we estimate and compare the geospatially-distributed cost of CPG and CO 2 storage across a portion of North America. We find that the locations with lowest-cost CO 2 storage are different than the locations with lowest-cost CPG. There are also locations with low-cost CO 2 storage (<$5/tCO 2 ) that do not support CPG power generation due to insufficient reservoir transmissivity or temperature. Thus, CPG development may require electricity prices that are greater than the levelized cost of electricity (LCOE) to offset the increased cost of sequestration. We introduce the “Additional Cost of Electricity (ACOE)” metric to account for this cost and add it to the LCOE to calculate breakeven electricity prices that are required for CPG development. We find that breakeven prices are lower when new CO 2 injection wells are drilled specifically for CPG (i.e., “greenfield” CPG development) compared to if only existing CO 2 sequestration injection wells are used (i.e., “brownfield” CPG development). This is because comparatively few wells are needed for sequestration-only, and the increased power capacity from having more CPG wells outweighs the increased costs from more drilling. We also find that sequestered CO 2 could be used to approximately triple the United States geothermal electricity power capacity via a single CPG “sweet spot” in South Dakota, but that breakeven electricity price for this development is on the order of $200/MW e h.

15 GEOTHERMAL ENERGY↗

Energy efficiency of blower heater non-purge compressed air dryers

This research focuses on twin tower regenerative closed loop desiccant dryers, specifically: blower heater non-purge (BHNP) with and without cooling water pumps, compressed-air heater purge (CHP), blower heater purge (BHP) and pressure swing heaterless (PSH). The research was conducted by collecting and analysing real time current draw data on air compressors and associated dryers at eight different facilities (13 air compressors) in terms of energy, power and cost. A decision tool was developed to depict the operational characteristics (power, energy and cost) of each type of dryer if used in conjunction with the selected compressor system. Finally, this research, on an equivalent normalised basis, compared and contrasted the different types of dryers in terms of performance and cost. Here, the research concluded that of the five types of desiccant dryer types observed the most energy efficient was the BHNP (with cooling water pump), subject to the operational conditions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Soft costs and EVSE – Knowledge gaps as a barrier to successful projects

There has been a recent push to increase access to electric vehicle (EV) charging infrastructure. The National Electric Vehicle Infrastructure (NEVI) program, part of the Bipartisan Infrastructure Law (BIL) has made significant funding available for major charging infrastructure projects along state thruways, and many state and local incentives exist for EV owners to install chargers in their homes. However, deployment of these chargers has not kept up with demand, primarily due to issues in project planning, permitting processes, and unforeseen delays. This paper serves as a review of the current understanding of these and other non-hardware costs in EV charging infrastructure projects (collectively known as “soft costs”). We found that soft costs in EV charging infrastructure projects are not well understood. Specifically, there is little agreement on how soft costs should be categorized and tracked, and less agreement still on best practices for controlling these costs and lowering barriers to infrastructure deployment. A broader review of EV charging infrastructure cost analyses shows that these costs can have significant impacts on project outcomes. EV charging infrastructure projects may be able to examine the success of the solar industry in lowering soft costs, and a similar effort may lower project costs significantly. Further work on standardizing and collecting data on EV charging infrastructure costs is required to begin addressing and controlling these costs.

32 - ENERGY CONSERVATION, CONSUMPTION, AND UTILIZA↗