Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “small sample size”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 865 records · Page 48

Advanced manufacturing of 3D custom boron-carbide collimators designed for complex environments for neutron scattering

Scattered-beam collimation is a very useful method to reduce unwanted backgrounds and to boost the desired sample signal instead. This approach is of particular interest for samples contained within a complex environment that gives rise to much unwanted parasitic scatter. As neutron scattering instrument and techniques advances, small samples are becoming of more and more interest, which necessitates optimized collimation. Here, in this work, we describe a concept for the design and fabrication of advanced scattered-beam collimation 3D printed from B 4 C specifically tailored for samples contained within a complex environment. This concept is demonstrated through the use of a diamond anvil cell for high pressure experimentation, a technique that very typically requires small samples. The collimators here are designed through a modeling procedure via Monte Carlo neutron ray tracing that encompasses the entire system: the instrument, the complex environment and the collimator. Since the first approach of simply scaling up of the print-size was not successful, a novel concept of a multi-part alternate-blade collimator was developed. This approach addresses printing constraints but gives greater flexibility in design. Its performance is computationally compared against an unprintable progressively tighter blade collimator to assess the effect of alternating blades. No strong difference was observed. Its performance was validated through experimentation at the Spallation Neutron Source. The results emphasize the critical importance of ultra-high precision alignment while showing good overall agreement between simulation and experiment and underscore the feasibility of the method and its real-world application.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Laser wakefield generated X-ray probe for femtosecond time-resolved measurements of ionization states of warm dense aluminum

We have developed a laser wakefield generated X-ray probe to directly measure the temporal evolution of the ionization states in warm dense aluminum by means of absorption spectroscopy. As a promising alternative to the free electron excited X-ray sources, Betatron X-ray radiation, with femtosecond pulse duration, provides a new technique to diagnose femtosecond to picosecond transitions in the atomic structure. The X-ray probe system consists of an adjustable Kirkpatrick-Baez (KB) microscope for focusing the Betatron emission to a small probe spot on the sample being measured, and a flat Potassium Acid Phthalate Bragg crystal spectrometer to measure the transmitted X-ray spectrum in the region of the aluminum K-edge absorption lines. An X-ray focal spot size of around 50 μm was achieved after reflection from the platinum-coated 10-cm-long KB microscope mirrors. Shot to shot positioning stability of the Betatron radiation was measured resulting in an rms shot to shot variation in spatial pointing on the sample of 16 μm. The entire probe setup had a spectral resolution of ∼1.5 eV, a detection bandwidth of ∼24 eV, and an overall photon throughput efficiency of the order of 10{sup −5}. Approximately 10 photons were detected by the X-ray CCD per laser shot within the spectrally resolved detection band. Thus, it is expected that hundreds of shots will be required per absorption spectrum to clearly observe the K-shell absorption features expected from the ionization states of the warm dense aluminum.

36 MATERIALS SCIENCE↗

Plural-wavelength flame detector that discriminates between direct and reflected radiation

A flame detector employs a plurality of wavelength selective radiation detectors and a digital signal processor programmed to analyze each of the detector signals, and determine whether radiation is received directly from a small flame source that warrants generation of an alarm. The processor's algorithm employs a normalized cross-correlation analysis of the detector signals to discriminate between radiation received directly from a flame and radiation received from a reflection of a flame to insure that reflections will not trigger an alarm. In addition, the algorithm employs a Fast Fourier Transform (FFT) frequency spectrum analysis of one of the detector signals to discriminate between flames of different sizes. In a specific application, the detector incorporates two infrared (IR) detectors and one ultraviolet (UV) detector for discriminating between a directly sensed small hydrogen flame, and reflections from a large hydrogen flame. The signals generated by each of the detectors are sampled and digitized for analysis by the digital signal processor, preferably 250 times a second. A sliding time window of approximately 30 seconds of detector data is created using FIFO memories.

Hall, Gregory H.↗

Microwave Nondestructive Evaluation of Dielectric Materials with a Metamaterial Lens

A novel microwave Nondestructive Evaluation (NDE) sensor was developed in an attempt to increase the sensitivity of the microwave NDE method for detection of defects small relative to a wavelength. The sensor was designed on the basis of a negative index material (NIM) lens. Characterization of the lens was performed to determine its resonant frequency, index of refraction, focus spot size, and optimal focusing length (for proper sample location). A sub-wavelength spot size (3 dB) of 0.48 lambda was obtained. The proof of concept for the sensor was achieved when a fiberglass sample with a 3 mm diameter through hole (perpendicular to the propagation direction of the wave) was tested. The hole was successfully detected with an 8.2 cm wavelength electromagnetic wave. This method is able to detect a defect that is 0.037 lambda. This method has certain advantages over other far field and near field microwave NDE methods currently in use.

Shreiber, Daniel↗

The Effects of Thermal Metamorphism on the Amino Acid Content of the CI-Like Chondrite Y-86029

Carbonaceous chondrites con-tain a diverse suite of amino acids that varies in abundance and structural diversity depending on the degree of aqueous alteration and thermal histo-ry that the parent body experienced [1 - 3]. We recently determined the amino acid contents of several fragments of the Sutter's Mill CM2 chon-drite [4]. In contrast with most other CM2 chon-drites, the Sutter's Mill meteorites showed minimal evidence for the presence of indigenous amino acids. A notable difference between the Sutter's Mill meteorites and other CM2 chondrites are that the Sutter's Mill stones were heated to tempera-tures of 150 - 400 C [4], whereas most other CM2 chondrites do not show evidence for thermal met-amorphism [5]. Because empirical studies have shown that amino acids rapidly degrade in aqueous solutions above 150 C and the presence of miner-als accelerates this degradation [6], a plausible explanation for the lack of amino acids observed in the Sutter's Mill meteorites is that they were destroyed during metamorphic alteration. Fewer CI chondrites have been analyzed for amino acids because only a small number of these meteorites have been recovered. Nevertheless, indigenous amino acids have been reported in the CI chondrites Ivuna and Orgueil [7]. Here we report on the amino acid analysis of the CI-like chondrite, Yamato 86029 (Y-86029; sample size of 110 mg). Just as the Sutter's Mill meteorites were thermally metamporphosed CM2 chondrites, Y-86029 has experienced thermal metamorphism at higher temperatures than Orgueil and Ivuna (normal CI chondrites) experienced, possibly up to 600 C [8].

Burton, A. S.↗

Inferred Variable FeO Content in Medium-sized Lunar Pyroclastic Deposits from LRO Diviner Data

Lunar pyroclastic deposits (LPDs) are low albedo features that mantle underlying terrain (Gaddis et al. 1985). They are high priority targets for science and exploration as they are believed to originate from and therefore reflect the composition of the deep lunar interior (NRC, 2011). They are also the best potential resource of oxygen out of any Apollo samples (Allen et al. 1996). Historically, LPDs have been divided into regional versus local categories (Gaddis et al. 2003). The large (>1000 km2 area) regional deposits are deeply sourced (>400 km deep) and result from fire fountaining. Small (<1000 km2) local deposits are thought to result from Vulcanian eruptions in which magma is slowly emplaced beneath the surface until enough volatiles exsolve and the high pressure causes an explosion. Bennett et al. (2013) identified a local deposit (674 km2 area) that may have resulted from both Vulcanian activity and fire fountaining. This deposit potentially represents a new intermediate class of LPDs that straddles the interface between the two formation mechanisms. The deposit also exhibits the highest inferred FeO wt.% of any known lunar glass. In this work we investigate the inferred FeO abundances of other medium-sized deposits to characterize this potential new class of deposits and understand the magnitude of variations in inferred FeO among pyroclastic deposits. We use the method of Greenhagen et al. (2010) to calculate the wavelength of the Christiansen Feature (CF) from Lunar Reconnaissance Orbiter Diviner Lunar Radiometer instrument thermal-infrared observations for four medium-sized deposits. From the CF values, we estimate each deposit's FeO abundance using the method of Allen et al. (2012). The four LPDs that we examined (Oppenheimer South, Beer, Cleomedes, and J. Herschel) all have average CF values from 8.22-8.28 microns, corresponding to FeO abundances of approx. 10-15 wt.%. All of these values are within the range and uncertainties of FeO abundances measured in Apollo samples. As previously identified, the Oppenheimer South deposit exhibits an area of enhanced CF values (8.49 microns) that, if the methods of Allen et al. (2012) can be extrapolated, correspond to a highest observed approx. 30 wt.% FeO. Moon Mineralogy Mapper near-infrared spectra indicate that this area is glass-rich as opposed to olivine-rich. While we are still investigating the nature of the high CF wavelength in Oppenheimer South, spatially-resolved observations there and (to a smaller degree) in our other study sites, shows that FeO wt.% can vary within LPDs. Thus, obtaining only the average FeO abundance over a large area may not be adequate to understand global variation. The magnitude of Oppenheimer South's CF variability, if due to actual surface variations rather than calibration artifacts or spectral mixing, could indicate that it is a unique deposit and not part of a new mid-sized class of deposits. The higher value could be a result of its location within the South Pole Aitken Basin and exsolution of more deeply sourced magma due to the thin crust there.

Bennett, K. A.↗

Rod-shaped silica particles derivatized with elongated silver nanoparticles immobilized within mesopores

Silver-derivatized silica particles possessing a non-spherical morphology and surface plasmon resonance properties have been achieved. Nanometer-sized silica rods with uniformly sized mesopore channels were prepared first making use of alkyltrimethyl ammonium surfactants as porogens and the 1:0.10 tetraethyl orthosilicate (TEOS) : 3-aminopropyltriethoxysilane (APTES) mixture as a silicon source. Silica rods were subsequently functionalized by introducing elongated silver nanoparticles within the intra-particle mesopores thanks to the AgNO{sub 3} reduction procedure based on the action of hemiaminal groups previously located on the mesopore walls. The textural and structural features of the samples were inferred from the combined characterization studies including SEM and TEM microscopy, nitrogen adsorption-desorption at 77 K, powder XRD in the small- and wide-angle region, as well as UV–visible spectroscopy. {sup 129}Xe NMR spectroscopy appeared particularly useful to obtain a correct information about the porous structure of rod-shaped silica particles and the silver incorporation within their intra-particle mesopores. - Highlights: • Mesoporous monodisperse submicron-sized silica rods were achieved. • Silver nanoparticles were located lengthwise within the intra-particle mesopores. • Textural and plasmonic properties of particles studied by {sup 129}Xe NMR and UV–Vis.

36 MATERIALS SCIENCE↗

Microfluidic sorting of protein nanocrystals by size for X-ray free-electron laser diffraction

The advent and application of the X-ray free-electron laser (XFEL) has uncovered the structures of proteins that could not previously be solved using traditional crystallography. While this new technology is powerful, optimization of the process is still needed to improve data quality and analysis efficiency. One area is sample heterogeneity, where variations in crystal size (among other factors) lead to the requirement of large data sets (and thus 10–100 mg of protein) for determining accurate structure factors. To decrease sample dispersity, we developed a high-throughput microfluidic sorter operating on the principle of dielectrophoresis, whereby polydisperse particles can be transported into various fluid streams for size fractionation. Using this microsorter, we isolated several milliliters of photosystem I nanocrystal fractions ranging from 200 to 600 nm in size as characterized by dynamic light scattering, nanoparticle tracking, and electron microscopy. Sorted nanocrystals were delivered in a liquid jet via the gas dynamic virtual nozzle into the path of the XFEL at the Linac Coherent Light Source. We obtained diffraction to ∼4 Å resolution, indicating that the small crystals were not damaged by the sorting process. We also observed the shape transforms of photosystem I nanocrystals, demonstrating that our device can optimize data collection for the shape transform-based phasing method. Using simulations, we show that narrow crystal size distributions can significantly improve merged data quality in serial crystallography. From this proof-of-concept work, we expect that the automated size-sorting of protein crystals will become an important step for sample production by reducing the amount of protein needed for a high quality final structure and the development of novel phasing methods that exploit inter-Bragg reflection intensities or use variations in beam intensity for radiation damage-induced phasing. This method will also permit an analysis of the dependence of crystal quality on crystal size.

36 MATERIALS SCIENCE↗

Flaw-insensitive fracture of a micrometer-sized brittle metallic glass

Brittle materials, such as oxide glasses, are usually very sensitive to flaws, giving rise to a macroscopic fracture strength that is much lower than that predicted by theory. The same applies to metallic glasses (MGs), with the important difference that these glasses can exhibit certain plastic strain prior to catastrophic failure. Here we consider the strongest metallic alloy known, a ternary Co 55 Ta10B 35 MG. In this work, we show that this macroscopically brittle glass is flaw-insensitive at the micrometer scale. This discovery emerges when testing pre-cracked specimens with self-similar geometries, where the fracture stress does not decrease with increasing pre-crack size. The fracture toughness of this ultra-strong glassy alloy is further shown to increase with increasing sample size. Both these findings deviate from our classical understanding of fracture mechanics, and are attributed to a transition from toughness-controlled to strength-controlled fracture below a critical sample size.

36 MATERIALS SCIENCE↗

Extraction of organic compounds from representative shales and the effect on porosity

This study is an attempt to understand how native organics are distributed with respect to pore size to determine the relationship between hydrocarbon chemistry and pore structure in shales, as the location and accessibility of hydrocarbons is key to understanding and improving the extractability of hydrocarbons in hydraulic fracturing. Selected shale cores from the Eagle Ford and Marcellus formations were subjected to pyrolysis gas chromatography (GC), thermogravimetric analysis, and organic solvent extraction with the resulting effluent analyzed by GC-mass spectrometry (MS). Organics representing the oil and gas fraction (0.1 to 1 wt. %) were observed by GC-MS. For most of the samples, the amount of native organic extracted directly related to the percentage of clay in the shale. The porosity and pore size distribution (0.95 nm to 1.35 m) in the Eagle Ford and Marcellus shales was measured before and after solvent extraction using small angle neutron scattering (SANS). An unconventional method was used to quantify the background from incoherent scattering as the Porod transformation obscures the Bragg peak from the clay minerals. Furthermore, the change in porosity from SANS is indicative of the extraction or breakdown of higher molecular weight bitumen with high C/H ratios (asphaltenes and resins). This is mostly likely attributed to complete dissolution or migration of asphaltenes and resins. These longer carbon chain lengths, C30-C40, were observed by pyrolysis GC, but either were too heavy to be analyzed in the extracts by GC-MS or were not effectively leached into the organic solvents. Thus, experimental limitations meant that the amount of extractable material could not be directly correlated to the changes in porosity measured by SANS. But, the observable porosity generally increased with solvent extraction. A decrease in porosity after extraction as observed in a shale with high clay content and low maturity was attributed to swelling of pores with solvent uptake or migration of resins and asphaltenes.

04 OIL SHALES AND TAR SANDS↗

High Spatial Resolution Imaging of Mouse Pancreatic Islets Using Nanospray Desorption Electrospray Ionization Mass Spectrometry

Nanospray Desorption Electrospray Ionization mass spectrometry imaging (nano-DESI MSI) enables ambient imaging of biological samples with high sensitivity and minimal sample pretreatment. Recently, we developed an approach for constant-distance mode MSI using shear force microscopy to precisely control the distance between the sample and the nano-DESI probe. Herein, we demonstrate the power of this approach for robust imaging of pancreatic islets with high spatial resolution of ~11 µm. Pancreatic islets are difficult to characterize using traditional mass spectrometry approaches due to their small size (~100 µm) and molecular heterogeneity. Nano-DESI MSI was used to examine the spatial localization of several lipid classes including phosphatidylcholine (PC), phosphatidylethanolamine (PE), sphingomyelin (SM), phosphatidylinositol (PI), and phosphatidylserine (PS) along with fatty acids and their metabolites (e.g., prostaglandins) in the individual islets and surrounding tissue. Several lipids were found to be substantially enhanced in the islets indicating these lipids may be involved in insulin secretion. Remarkably different distributions were observed for several pairs of Lyso PC (LPC) and PC species differing only by one double bond, such as LPC 18:1 vs LPC 18:0, PC 32:1 vs PC 32:0, and PC 34:2 vs PC 34:1. These findings indicate that minor variations in the fatty acid chain length and saturation have a pronounced effect on the localization of PC and LPC species in pancreatic islets. Interestingly, oxidized PC species observed experimentally were found to be specifically localized to pancreatic islets. These PCs are potential biomarkers for reactive oxygen species in the islets, which could be harmful to pancreatic beta cells. The experimental approach presented in this study will provide valuable information on the heterogeneity of individual pancreatic islets, which is difficult to assess using bulk characterization techniques.

Yin, Ruichuan↗

Correction and calibration of atmospheric impact observations in GOES GLM data

The Earth's atmosphere is impacted daily by both meteoroids and artificial objects. Calibrated observations of the emitted light at sufficiently high sampling rates can enable or improve the estimation of impactor attributes such as size, cohesion, trajectory, and composition, but are difficult to obtain owing to the unpredictability, brevity, and high dynamic (brightness) range of impacts. Ground-based camera systems have successfully monitored small regions of the atmosphere at video frame rates and with limited radiometric capabilities, but most impacts occur over the 70% of the Earth's surface covered by water and are therefore missed by these networks. The Geostationary Lightning Mapper (GLM) instruments aboard Geostationary Operational Environmental Satellites 16 and 17 provide near-hemispherical coverage at 500 frames per second. These data have been shown to contain the signatures of many independently confirmed impacts, often from both viewing angles simultaneously, and constitute an observational resource that is currently unparalleled in the public domain. NASA's Asteroid Threat Assessment Project has implemented an automated impact detection pipeline that processes data from GLM daily. Given a detected impact, the GLM data contain a wealth of information for use in quantitative follow-up analyses. However, impact events differ from lightning in ways that violate key assumptions built into GLM's design. The result is that GLM's onboard processing introduces errors into pixel observations of impact events and the calibrated energies near the periphery of the detector may be substantially overestimated. We present methods for mitigating these and other issues to produce a data product more suitable for impact analyses than the existing GLM lightning product.

58 GEOSCIENCES↗

Surface texture of Vesta from optical polarimetry

Polarimetric, photometric, and reflective spectroscopic properties of asteroid 4 Vesta are simulated in the laboratory by a preparation of eucrite Bereba consisting of a broad mixture of particle sizes (mainly greater than 50-micron) mixed and partially coated with particles of size 10 microns and less. Coarse grains are necessary for producing the same albedo and a very fine dust coating is necessary for producing the same polarization inversion angle as observed for Vesta. There are less small grains and fine dust in this sample than in lunar soils. Photometrically, if coating a sphere, this sample shows a constant brightness on the sunward half of the observed hemisphere, the brightness being given on the other half by the Minnaert reciprocity principle. With such a photometric behavior, the global geometric albedo and the sub-earth point geometric albedo differ by no more than 5%. The microscopic phase coefficient is 0.021 magnitude per degree for the sample; the larger value, 0.025, observed telescopically for Vesta, indicates that large-scale roughness is present on this asteroid.

Le Bertre, T.↗

Retrieval of Precipitation Profiles from Multiresolution, Multifrequency, Active and Passive Microwave Observations

In this study, a technique for estimating vertical profiles of precipitation from multifrequency, multiresolution active and passive microwave observations is investigated using both simulated and airborne data. The technique is applicable to the Tropical Rainfall Measuring Mission (TRMM) satellite multi-frequency active and passive observations. These observations are characterized by various spatial and sampling resolutions. This makes the retrieval problem mathematically more difficult and ill-determined because the quality of information decreases with decreasing resolution. A model that, given reflectivity profiles and a small set of parameters (including the cloud water content, the intercept drop size distribution, and a variable describing the frozen hydrometeor properties), simulates high-resolution brightness temperatures is used. The high-resolution simulated brightness temperatures are convolved at the real sensor resolution. An optimal estimation procedure is used to minimize the differences between simulated and observed brightness temperatures. The retrieval technique is investigated using cloud model synthetic and airborne data from the Fourth Convection And Moisture Experiment. Simulated high-resolution brightness temperatures and reflectivities and airborne observation strong are convolved at the resolution of the TRMM instruments and retrievals are performed and analyzed relative to the reference data used in observations synthesis. An illustration of the possible use of the technique in satellite rainfall estimation is presented through an application to TRMM data. The study suggests improvements in combined active and passive retrievals even when the instruments resolutions are significantly different. Future work needs to better quantify the retrievals performance, especially in connection with satellite applications, and the uncertainty of the models used in retrieval.

Grecu, Mircea↗

Infrared Spectroscopy of the Dust in Comets and Relationships to Interstellar Dust

Infrared spectroscopy of the dust in comets reveals a complex mix of silicate materials, including both crystalline and non-crystalline components of both olivine (forsterite) and pyroxene composition. These various components do not necessarily share a common origin. Since comets formed in cold regions of the solar nebula, pre-solar grains in the nebula could have been accreted into comets with little alteration. Some of the cometary silicates may be of circumstellar (formed in circumstellar outflows of evolved stars) or interstellar (formed in dense region of the interstellar medium) origin. Spectral similarities to both circumstellar and interstellar silicates are seen in comet spectra. the short-period Kuiper Belt comets) show weak or no spectral features. The lack of features is generally explained as a particle size effect: the small silicate grains are embedded in larger, optically thick particles. However, compositional differences cannot be ruled out. For example, no unambiguous signature of forsterite has yet been seen in the spectrum of a short-period comet. Thus, the Stardust sample from short-period comet P/Wild 2 will be extremely valuable. Not only grain by grain composition and isotopic ratios but also grain morphology, irradiation history, and evidence of organic refractory mantles are important for understanding their origin. The relative abundance and distinguishing characteristics of the various crystalline and non-crystalline silicate components needs to be established. While some comets, such as Hale-Bopp, display a rich infrared spectrum, others (particularly

Hanner, Martha S.↗

Plasma Interactions with a Negative Biased Electrodynamic Tether

The ProSEDS conductive tether design incorporates two distinct types of tethers from a plasma interaction viewpoint. The 200 m closest to the Delta 11 spacecraft is insulated from the plasma, and the remaining 5000 m is semi-bare. This latter portion is semi-bare because it has a conductive coating applied to the wires to permit electron collection while also regulating the overall tether temperature. Because the tether possesses these two distinct types of tethers, a transition point exists between the two types that form a triple point with the space plasma. Insulated tethers can suffer from a second plasma interaction if the insulation is weakened or breached, such as by pinholes caused by small particle debris strikes. Because electrodynamic tethers are typically long, they have a high probability of such impacts. These impacting particles may not be of sufficient size to severe the tether, but they can easily be of sufficient size to damage the tether insulation. Samples of both the ProSEDS tether transition region and the insulated tether section (with various degrees of pinhole damage) were placed into the MSFC plasma chamber and biased to typical ProSEDS open circuit tether potentials (-500 V to -1600 V). The results of the testing showed that the transition region of the tether (i.e. the triple point) arced and burned the tether in two at -900 V, and the damaged insulated sections arced and burned in two between -1000 V and -1600, depending on the pinhole damage geometry. tether design and make the tether ready for flight. To reduce the pinhole arcing risk, ProSEDS mission operations were changed to eliminate the negative potential on the tether. The results of the testing campaign and the design changes implemented to ensure a successful flight will be described.

Vaughn, Jason A.↗

Direct Simulation Monte Carlo Studies of the Gas Sampling for the VATMOS-SR Mission Concept

VATMOS-SR (Venus ATMOSpheric - Sample Return) is a small spacecraft mission concept which would return a gas sample from the upper atmosphere of Venus to Earth for scientific analysis. This could be the first sample return mission for an extra-terrestrial atmosphere, and potentially the first sample return from an Earth-sized planet. The VATMOS-SR mission concept consists of a SmallSat atmospheric sampling probe (45 deg. sphere/cone geometry, <1 m diameter) that is designed to skim through the Venus upper atmosphere and acquire gas samples below the homopause altitude (around ~110 km altitude), where the different atmospheric gases are mixed. The velocity of the spacecraft where sampling would occur is expected to be between ~10.5 km/s and ~13.1 km/s, depending on the trajectory chosen. This presentation will discuss hypervelocity sampling in the upper atmosphere of Venus, with respect to the VATMOS-SR mission concept. VATMOS-SR would enable critical atmospheric measurements to form a full picture of how, why, and when Venus evolved to be so different from Earth and Mars. The abundances and isotopic compositions of volatile elements (such as N, C, S, O and the noble gases) in planetary atmospheres record volatile delivery during accretion, outgassing from planetary interiors, and atmospheric loss to space. Precise and accurate determinations of atmospheric volatile signatures are the key to understanding the origins and geodynamical evolution of Venus compared to the other terrestrial planets. Hypersonic sampling poses unique technical and scientific challenges. To ensure it is possible to relate the composition of the sampled gases to the free stream atmospheric composition, large-scale numerical simulations are employed to model the flow through the VATMOS-SR sampling system. In particular, an emphasis is placed on quantifying noble gas isotopic fractionation that occurs during the sample acquisition and transfer process in order to determine how measured isotopic ratios of noble gases in the sample compare to actual isotopic ratios in the Venusian atmosphere. The Direct Simulation Monte Carlo (DSMC) code SPARTA, an open source software package developed by Sandia National Laboratories, is used in this work. SPARTA, based on Bird’s DSMC method, is a molecular-level gas-kinetic technique. As SPARTA is able to model hypervelocity reacting flows in strong chemical and thermal non-equilibrium, this software package is well suited to determine relevant flow properties for the VATMOS-SR mission concept, and to numerically quantify the expected level of elemental and/or isotopic fractionation in the sample acquired by VATMOS-SR. This presentation will show results from 3D simulations correlating the noble gas isotopic fractionation in the gas acquired at hypervelocity speeds to its ambient atmosphere value. In particular, emphasis will be placed at Xenon isotopes of masses 128 and 130, as precise measurements of that ratio would yield a comparison to Earth’s atmosphere. Additionally, sensitivity studies that quantify the uncertainties due to the freestream parameters as well as the modeling parameters will be performed.

direct simulation Monte Carlo↗

The VATMOS-SR Mission Concept: DSMC Studies of the Gas Sampling

VATMOS-SR (Venus ATMOSpheric - Sample Return) is a small spacecraft mission concept that would return a gas sample from the upper atmosphere of Venus to Earth for scientific analysis. This could be the first sample return mission for an extra-terrestrial atmosphere and potentially the first sample return from an Earth-sized planet. The VATMOS-SR mission concept consists of a SmallSat atmospheric sampling probe (45 deg. sphere/cone geometry, <1 m diameter) that is designed to skim through the Venus upper atmosphere and acquire gas samples below the homopause altitude (around ~110 km altitude), where the different atmospheric gases are mixed. The velocity of the spacecraft where sampling would occur is expected to be between ~10.5 km/s and ~13.1 km/s, depending on the trajectory chosen. This presentation will discuss hypervelocity sampling in the upper atmosphere of Venus with respect to the VATMOS-SR mission concept. VATMOS-SR would enable critical atmospheric measurements to form a complete picture of how, why, and when Venus evolved to be so different from Earth and Mars. The abundances and isotopic compositions of volatile elements (such as N, C, S, O, and the noble gases) in planetary atmospheres record volatile delivery during accretion, outgassing from planetary interiors, and atmospheric loss to space. Precise and accurate determinations of volatile atmospheric signatures are the key to understanding the origins and geodynamical evolution of Venus compared to the other terrestrial planets. Hypersonic sampling poses unique technical and scientific challenges. To ensure it is possible to relate the composition of the sampled gases to the free stream atmospheric composition, large-scale numerical simulations are employed to model the flow through the VATMOS-SR sampling system. In particular, an emphasis is placed on quantifying noble gas isotopic fractionation that occurs during the sample acquisition and transfer process to determine how measured isotopic ratios of noble gases in the sample compared to actual isotopic ratios in the Venusian atmosphere. The Direct Simulation Monte Carlo (DSMC) code SPARTA, an open-source software package developed by Sandia National Laboratories, is used in this work. SPARTA, based on Bird’s DSMC method, is a molecular-level gas-kinetic technique. As SPARTA is able to model hypervelocity reacting flows in strong chemical and thermal non-equilibrium, this software package is well suited to determine relevant flow properties for the VATMOS-SR mission concept and to numerically quantify the expected level of elemental and/or isotopic fractionation in the sample acquired by VATMOS-SR. This presentation will show results from 3D simulations correlating the noble gas isotopic fractionation in the gas acquired at hypervelocity speeds to its ambient atmosphere value. In particular, emphasis will be placed on Xenon isotopes of masses 128 and 130, as precise measurements of that ratio would yield comparison to Earth’s atmosphere. Additionally, sensitivity studies that quantify the uncertainties due to the freestream parameters, as well as the modeling parameters, will be performed.

direct simulation Monte Carlo↗