Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “sample integrity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 865 records · Page 48

POST-TEST EXAMINATIONS OF A LOCA SAMPLE FROM AN IRRADIATED HIGH-BURNUP PWR M5 FUEL ROD

A LOCA integral test with high burnup PWR M5 fuel rod was conducted in the Irradiated Fuel Examination Laboratory through the complete LOCA sequence: heating the LOCA sample to 300ºC and pressurizing the internal pressure to 8.27 MPa, heating at 5ºC/s from 300 to 1200ºC, holding in steam for 90s at 1200ºC, cooling at 3ºC/s to 800ºC, followed by water quench and rapid cooling to 100ºC. After LOCA testing, examinations, such as the fuel fragmentation analysis, burst and ballooning characterization, axial strain measurement, and microstructural examinations were performed. Metallographic examinations of an as-irradiated high burnup sample adjacent to the LOCA test sample revealed a bonding layer between the fuel and cladding. The posttest LOCA examinations indicates the corrosion layer formed during normal operations in the commercial reactor might provide a protection against the steam oxidation at high temperatures for test times performed in this work. The microstructure of the as-irradiated fuel is compared to the microstructure of the post-LOCA test fuel. Posttest LOCA examination on unirradiated post-tests Zr cladding samples was conducted, which served as baseline data for in cell testing with irradiated samples. The results obtained with irradiated PWR high burnup M5 fuel rad were compared to the LOCA test data obtained with irradiated BWR high burnup Zircaloy-2 fuel rod at Argonne national Laboratory.

Yan, Yong↗

Altered white matter connectivity in patients with schizophrenia: An investigation using public neuroimaging data from SchizConnect

Several studies have produced extensive evidence on white matter abnormalities in schizophrenia (SZ). However, optimum consistency and reproducibility have not been achieved, and reported low white matter tract integrity in patients with SZ varies between studies. A whole-brain imaging study with a large sample size is needed. This study aimed to investigate white matter integrity in the corpus callosum and connections between regions of interests (ROIs) in the same hemisphere in 122 patients with SZ and 129 healthy controls with public neuroimaging data from SchizConnect. For each diffusion-weighted image (DWI), two-tensor full-brain tractography was performed; DWIs were parcellated by processing and registering T1 images with FreeSurfer and Advanced Normalization Tools. White matter query language was used to extract white matter fiber tracts. We evaluated group differences in means of diffusion measures between the patients and controls, and correlations of diffusion measures with the severity of clinical symptoms and cognitive impairment in the patients using the Positive and Negative Syndrome Scale (PANSS), a letter-number sequencing (LNS) test, vocabulary test, letter fluency test, category fluency test, and trail-making test, part A. To correct for multiple comparisons, a false discovery rate of q < 0.05 was applied. In patients with SZ, we observed significant radial diffusivity (RD) and trace (TR) increases in left thalamo-occipital tracts and the right uncinate fascicle, and a significant RD increase in the right middle longitudinal fascicle (MDLF) and the right superior longitudinal fascicle ii. Correlations were present between TR of left thalamo-occipital tracts, and the letter fluency test and the LNS test, and RD in the right MDLF and PANSS positive subscale score. However, these correlations were not significant after correction for multiple comparisons. These results indicated widespread white matter fiber tract abnormalities in patients with SZ, contributing to SZ pathophysiology.

60 APPLIED LIFE SCIENCES↗

High Precision and Spatial Resolution Chemical Interrogation of Planetary Materials Using fs-LA/LIBS in Tandem With Multi-Collector ICP-MS

Combining femtosecond laser ablation (fs-LA) with laser-induced breakdown spectroscopy (LIBS), together with multi-collector inductively coupled plasma mass spectrometry (MC-ICPMS), can provide remarkable insights into the composition, structure, and therefore geologic history of planetary materials and their terrestrial analogs. Using the Applied Spectra iX-fs-Tandem LA-LIBS Instrument and the Nu SP1700 MC-ICP-MS housed within the Center for Isotope Cosmochemistry and Geochronology at NASA Johnson Space Center, we present preliminary tandem fs-LA-(MC)-ICP-MS/LIBS measurements of planetary analog materials. The synergistic integration of fs-LA-LIBS offers high spatial resolution elemental mapping, enabling the identification of microscale variations within samples. Simultaneously, the MC-ICP-MS can deliver precise isotopic analyses, and integrating the two datasets yields a wealth of geochemical information for a given sample. LA-based chemical mapping experiment designs are contingent on the information sought (i.e., quantitative, or semi-quantitative) and the preferred or available volume of material removed for the analysis. For example, occasionally, there are significant limitations in the depth of ablation due to the sample value, the amount of material available, or simply the need to coordinate with other in-situ techniques. In these limited sample scenarios, the “depth-controlled” chemical maps allow for precise post-mapping ion-polishing of the sample, while the isotopic and elemental maps can be used for targeting future analyses (e.g., conventional LA analyses, SIMS analyses, and micro milling for solution ICP-MS/TIMS). The emerging methodology will establish a powerful tool for investigation of astromaterials and materials returned by future planetary sample science missions.

Jacob B Setera↗

Critical Current Stability of 2G REBCO Tape for Space-Flight HTS Leads

High reliability is an essential requirement for all spaceflight hardware. XRISM, a follow-on mission to the Hitomi x-ray observatory, also uses 2G REBCO tapes as current leads for the superconducting magnets that are a key component of the Adiabatic Demagnetization Refrigerator (ADR) that cools the detector array. While the Hitomi Soft X-ray Spectrometer (SXS) worked flawlessly in orbit, during its development there were indications that the critical current of its specialized REBCO tapes could degrade over time when exposed to normal-humidity air. To demonstrate that the updates to the XRISM HTS lead assemblies had mitigated this risk, a series of tests were carried out to measure the stability of Ic of dozens of samples over a period greater than the flight assemblies were exposed to air during integration and test. The test rig allowed not only the measurement of the sample Ic, but also the localization of the voltage rise as the current approached Ic. We will discuss the trends in the critical current of the samples, as well as localization of lower Ic regions.

Edgar R. Canavan↗

Effect of heat treatment on the microstructure of medium burn-up U-Mo monolithic fuel foils

Using scanning electron microscopy (SEM), this study evaluates the microstructure evolution of U-Mo fuel foils made with and without heat treatment at medium burn-up (of approximately 5 x 10 21 f/cm 3 ). The impact of annealing treatments on critical microstructural properties of the U-Mo fuel foils, including porosity, grain structure, Mo homogeneity, and fuel interaction with the Zr interlayer, was examined using large area lift outs (LALOs). The heat-treated specimens presented less grain refining at these burnups when compared to the un-heated specimens. Grain refinement was associated with porosities and fission products precipitation. Heat treatment can reduce fuel swelling during irradiation. Chemical inhomogeneity (Mo banding) was found to persist in the un-heated samples but was not present in the heat-treated samples. Thus, heat-treated U-Mo foils allows for more predictable fuel behavior under irradiation with respect to un-heated foils. The U-Mo and Zr interaction layer appears to be thicker and more continuous in the heat-treated sample which has been associated with stronger interface integrity during irradiation, as also observed in previous studies. These observations may indicate an overall improved performance of heat-treated fuel foil in a reactor. Further, the effect of local burn-up on grain size/refinement and porosities in each LALO specimen, sampled from different positions in the fuel foil, was difficult to analyze due to the large standard deviation of these parameters. Finally, evidence of grain refinement by polygonization may be present in these specimens.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

An expert system shell for inferring vegetation characteristics

The NASA VEGetation Workbench (VEG) is a knowledge based system that infers vegetation characteristics from reflectance data. VEG is described in detail in several references. The first generation version of VEG was extended. In the first year of this contract, an interface to a file of unknown cover type data was constructed. An interface that allowed the results of VEG to be written to a file was also implemented. A learning system that learned class descriptions from a data base of historical cover type data and then used the learned class descriptions to classify an unknown sample was built. This system had an interface that integrated it into the rest of VEG. The VEG subgoal PROPORTION.GROUND.COVER was completed and a number of additional techniques that inferred the proportion ground cover of a sample were implemented. This work was previously described. The work carried out in the second year of the contract is described. The historical cover type database was removed from VEG and stored as a series of flat files that are external to VEG. An interface to the files was provided. The framework and interface for two new VEG subgoals that estimate the atmospheric effect on reflectance data were built. A new interface that allows the scientist to add techniques to VEG without assistance from the developer was designed and implemented. A prototype Help System that allows the user to get more information about each screen in the VEG interface was also added to VEG.

Harrison, P. Ann↗

Approach to Low-Cost High-Efficiency OLED Lighting. Building Technologies Solid State Lighting (SSL) Program Final Report

This project developed an integrated substrate which organic light emitting diode (OLED) panel developers could employ the integrated substrate to fabricate OLED devices with performance and projected cost meeting the MYPP targets of the Solid State Lighting Program of the Department of Energy. The project optimized the composition and processing conditions of the integrated substrate for OLED light extraction efficiency and overall performance. The process was further developed for scale up to a low-cost process and fabrication of prototype samples. The encapsulation of flexible OLEDs based on this integrated substrate was also investigated using commercial flexible barrier films.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Report on partially complete post-irradiation-examination of the INL samples

Ferritic-martensitic steels (NF616 and T91), and austenitic stainless steel 800H and its Grain Boundary Engineering (GBE)-treated version 800H-TMP (ThermoMechanical Processing) were irradiated in the Advanced Test Reactor (ATR) at Idaho National Laboratory (INL) and their microstructures and mechanical properties were characterized. Ferritic-martensitic steels were irradiated up to 8.16 dpa in the irradiation temperatures ranging from 241 °C to 447.5 °C. Selected 800H and 800H-TMP samples were also irradiated up to 9.12 dpa at 359°C to 431°C. Vickers hardness measurement, fractography, and microstructural characterization were performed on the selected samples in the LAMDA lab. Radiation-induced hardening of NF616 and T91 was observed in the hardness measurements which show ~37% to ~65% increases, depending on irradiation dose and irradiation temperature. Within the irradiation conditions studied in this work, samples with a higher dose had a higher hardness. All the tested alloy 800H and 800H-TMP in this work showed irradiation-hardening by ~96±7% to ~152±10%. Alloy 800HTMP tended to have slightly smaller irradiation-hardening than alloy 800H. The fractography of NF616 samples D2 (2.96 dpa at 291.5°C), D4 (5.91 dpa at 359°C), and D6 (8.16 dpa at 431°C) indicated loss of ductility with negligible necking for the sample D2, yet obvious ductile failure for samples D4 and D6. Fractography of alloy 800H samples N4 (7.27 dpa at 359°C), N5 (3.9 dpa at 451.5°C), and N6 (9.01 dpa at 431°C), and alloy 800H-TMP samples P4 (7.36 dpa at 359°C), P5 (3.95 dpa at 451.5°C), and P6 (9.12 dpa at 431°C) indicated that all samples failed in a ductile mode, with obvious necking. Dimples were observed where large Ti-containing particles were observed for the samples. TEM characterization was performed on alloy 800H (N4, N5, N6) and 800H-TMP (P4, P5 and P6). Accumulation of M23C6 precipitates at grain boundaries was observed in all samples, and the presence of Ti(C,N) precipitates at grain boundaries and in the matrix was observed in alloy 800H-TMP. M23C6 precipitates were found to have the cube-on-cube orientation relationship with the matrix. In addition, nanoscale Si-rich clusters were observed in the matrix of all samples. Atom probe tomography was conducted on the same samples, and their results are being analyzed to be integrated with the TEM results for a confident description of the clustering behavior. Due to the low irradiation temperature (up to 451.5°C), dislocation loops formed in all samples, with the density and the average size of dislocation loops in the order of 1022 – 1023 m-3 and 11.7 – 15.9 nm, respectively. The loop densities in alloy 800H were higher than that in alloy 800H-TMP under the same irradiation conditions. Further systematic data analyses, together with some complementary experiments, will be pursued for these samples to foster peer-reviewed journal article publications.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Three Alternative Symbol-Lock Detectors

Three symbol-lock detectors proposed as alternatives in advanced receivers processing non-return-to-zero binary data signals. Two perform operations similar to those of older square-law and absolute-value types. However, integrals computed during nonoverlapping symbol periods and, therefore, only one integrator needed in each such detector. Proposed detectors simpler, but performances worse because noises in overlapping samples correlated, whereas noises in nonoverlapping samples not correlated. Third detector is signal-power-estimator type. Signal integrated during successive half symbol cycles, and therefore only one integrator needed. Half-cycle integrals multiplied to eliminate effect of symbol polarity, and products accumulated during M-cycle observation period to smooth out estimate of signal power. If estimated signal power exceeds threshold, delta, then lock declared.

Shihabi, Mazen M.↗

Aerothermal Effects of Cavities and Protuberances for High-Speed Sample Return Capsules

Extraterrestrial sample return is a growing component of solar system exploration. Currently, four missions, Stardust, 1 Muses-C, 2 Genesis, and Mars Sample Return, are under development that employ sample return as a prime component of the mission architecture. Respectively, these missions will return samples from the tail of a comet, an asteroid, the solar wind, and, Mars. An important component of these missions and the focus of this paper is the design of the sample return capsule (SRC). The purpose of the SRC is to safely return to Earth any gathered samples for terrestrial analysis. The two major design constraints for any SRC are as follows: 1) it must be able to survive a high-speed Earth entry (11 km/s to as a high as 15 km/s), 2) the mass of the SRC must be as small as possible. Because the SRC mass is carried from Earth to the sample sight and back, the SRC mass is a strong driver in the mission mass budget. Further, for the Mars Sample Return Capsule, planetary protection is another constraint. For this capsule, the probability of planetary contamination at Earth due to an SRC failure at entry must be minimal. For an SRC, a possible failure mechanism is severe local heating as a result of cavities and or protuberances in the SRC forebody heatshield. For example, the Apollo Command Module had a number of cavities and protuberances as part of the baseline designs Wind-tunnel tests of models containing small cavities and protuberances showed severe local heating augmentations in the vicinity of these surface discontinuities.4-5 As another example, the Genesis SRC forebody heat-shield contains penetrations (cavities) to mount the vehicle to the carrier bus. It is expected that these penetrations will also experience a severe local heating environment. A concern is that the large thermal gradients may produce sufficient thermal stress to cause local mechanical failure of the heatshield. Penetrations to the forebody heat-shield can also result from damage at vehicle integration, during launch, or during transportation of the sample return capsule from earth to the sample site and back. For example, the Starting SRC was damaged near the shoulder during the heatshield integration process producing a local surface discontinuity. Also, the Starting SRC traverses through the tail of a comet and is in space for 7 years. Thus, damage to the heatshield as a result of micrometeroid impact is a concern. Finally, it is difficult to characterize the effects of these potential heatshield singularities with ground-test facilities. Either detailed simulation or a dedicated flight test is required.

Olynick, David↗

Numerical Evaluation of the "Dual-Kernel Counter-flow" Matric Convolution Integral that Arises in Discrete/Continuous (D/C) Control Theory

Discrete/Continuous (D/C) control theory is a new generalized theory of discrete-time control that expands the concept of conventional (exact) discrete-time control to create a framework for design and implementation of discretetime control systems that include a continuous-time command function generator so that actuator commands need not be constant between control decisions, but can be more generally defined and implemented as functions that vary with time across sample period. Because the plant/control system construct contains two linear subsystems arranged in tandem, a novel dual-kernel counter-flow convolution integral appears in the formulation. As part of the D/C system design and implementation process, numerical evaluation of that integral over the sample period is required. Three fundamentally different evaluation methods and associated algorithms are derived for the constant-coefficient case. Numerical results are matched against three available examples that have closed-form solutions.

Nixon, Douglas D.↗

Dimension-free path-integral molecular dynamics without preconditioning

Convergence with respect to imaginary-time discretization (i.e., the number of ring-polymer beads) is an essential part of any path-integral-based molecular dynamics (MD) calculation. However, an unfortunate property of existing non-preconditioned numerical integration schemes for path-integral molecular dynamics—including essentially all existing ring-polymer molecular dynamics (RPMD) and thermostatted RPMD (T-RPMD) methods—is that for a given MD time step, the overlap between the exact ring-polymer Boltzmann–Gibbs distribution and that sampled using MD becomes zero in the infinite-bead limit. This has clear implications for hybrid Metropolis Monte Carlo/MD sampling schemes, and it also causes the divergence with bead number of the primitive path-integral kinetic-energy expectation value when using standard RPMD or T-RPMD. We show that these and other problems can be avoided through the introduction of “dimension-free” numerical integration schemes for which the sampled ring-polymer position distribution has non-zero overlap with the exact distribution in the infinite-bead limit for the case of a harmonic potential. Most notably, we introduce the BCOCB integration scheme, which achieves dimension freedom via a particular symmetric splitting of the integration time step and a novel implementation of the Cayley modification [R. Korol et al., J. Chem. Phys. 151, 124103 (2019)] for the free ring-polymer half-steps. More generally, we show that dimension freedom can be achieved via mollification of the forces from the external physical potential. The dimension-free path-integral numerical integration schemes introduced here yield finite error bounds for a given MD time step, even as the number of beads is taken to infinity; these conclusions are proven for the case of a harmonic potential and borne out numerically for anharmonic systems that include liquid water. The numerical results for BCOCB are particularly striking, allowing for nearly three-fold increases in the stable time step for liquid water with respect to the Bussi–Parrinello (OBABO) and Leimkuhler (BAOAB) integrators, while introducing negligible errors in the calculated statistical properties and absorption spectrum. Importantly, the dimension-free, non-preconditioned integration schemes introduced here preserve ergodicity and global second-order accuracy, and they remain simple, black-box methods that avoid additional computational costs, tunable parameters, or system-specific implementations.

Korol, Roman (ORCID:0000000193076351)↗

Prediction of tissue optical properties using the Monte Carlo modeling of photon transport in turbid media and integrating spheres

Monte Carlo methods are an established technique for simulating light transport in biological tissue. Integrating spheres make experimental measurements of the reflectance and transmittance of a sample straightforward and inexpensive. This work presents an extension to existing Monte Carlo photon transport methods to simulate integrating sphere experiments. Crosstalk between spheres in dual-sphere experiments is accounted for in the method. Analytical models, previous works on Monte Carlo photon transport, and experimental measurements of a synthetic tissue phantom validate this method. We present two approaches for using this method to back-calculate the optical properties of samples. Experimental and simulation uncertainties are propagated through both methods. Both back-calculation methods find the optical properties of a sample accurately and precisely. Our model is implemented in standard Python 3 and CUDA C++ [J. Nickolls, I. Buck, M. Garland, and K. Skadron, ACM Queue 6 , 40 ( 2008 ) ] and is publicly available in Code 1.

Cook, Patrick D. (ORCID:0000000279345428)↗

Magnetic Barkhausen noise characterization of two pipeline steels with unknown history

Highlights: • The hardness, microstructure, texture and MBN of two pipeline steels were analyzed. • The angular MBN results revealed possible manufacturing histories of the two pipelines. • The MBN is closely related to the processing history, microstructure and stress state. • The use of MBN technique can help address the integrity issues in the pipeline industry. Steel samples cut from two line pipes with unknown processing history were analyzed using magnetic Barkhausen noise (MBN), electron backscatter diffraction (EBSD) and Vickers hardness techniques on the pipe surface and on sections through the wall thickness. The results show that the MBN responses vary significantly not only between the two pipe steels, but also among different thickness layers of each steel. Both steels show considerable variations in MBN at different locations on the surfaces. For one steel, the surface MBN illustrates an inverse linear relationship with respect to the hardness, while the other does not depict such a relation since the variation in hardness at different locations is very small. Across the thickness, the microstructure (phase and grain size) of both steels is quite similar, but the texture shows significant differences. Again, there is a large difference in hardness across the thickness for one steel, while the other only shows very small variation in hardness across the thickness. The variations in average MBN across the wall thickness for both steels are quite large. Angular MBN measurements on the sectioned samples revealed significant discrepancies in the magnetic anisotropy in the two steels. Based on the analysis of the angular MBN data with respect to the single and dual easy axis models, one pipe can be determined to have been manufactured through a seam welding process, while the other may have been formed by spiral welding. Due to the residual stresses in the steel samples, the effect of the crystallographic texture on the anisotropy in MBN response has essentially been suppressed.

36 MATERIALS SCIENCE↗

Soft Three-Dimensional Microscale Vibratory Platforms for Characterization of Nano-Thin Polymer Films

Vibrational resonances of microelectromechanical systems (MEMS) can serve as means for assessing physical properties of ultrathin coatings in sensors and analytical platforms. Most such technologies exist in largely two-dimensional configurations with a limited total number of accessible vibration modes and modal displacements, thereby placing constraints on design options and operational capabilities. This study presents a set of concepts in three-dimensional (3D) microscale platforms with vibrational resonances excited by Lorentz-force actuation for purposes of measuring properties of thin-film coatings. Nanoscale films including photodefinable epoxy, cresol novolak resin, and polymer brush with thicknesses as small as 270 nm serve as the test vehicles for demonstrating the advantages of these 3D MEMS for detection of multiple physical properties, such as modulus and density, within a single polymer sample. The stability and reusability of the structure are demonstrated through multiple measurements of polymer samples using a single platform, and via integration with thermal actuators, the temperature-dependent physical properties of polymer films are assessed. Numerical modeling also suggests the potential for characterization of anisotropic mechanical properties in single or multilayer films. Finaly, the findings establish unusual opportunities for interrogation of the physical properties of polymers through advanced MEMS design.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Platform for Automated Anomaly Detection in the Mercury Process System at the Target System in the Spallation Neutron Source

The Spallation Neutron Source (SNS) at Oak Ridge National Laboratory accelerates proton beams, which are directed toward a mercury target to generate the world’s most intense neutron beams via spallation. The target system consists of several interconnected subsystems and accounts for a major share of the facility’s overall downtime. Early detection of anomalies in the target system response can thus provide the possibility of taking corrective actions to reduce downtime. Accelerator facilities have largely focused on the beam side for data-driven fault prognostics. On the target side, SNS relies on operational shift technicians (OSTs), who respond to alarms and manually flag anomalies onto the System Tracking and Reliability (STAR) platform. This paper presents one of the first studies of using machine learning (ML) to automate anomaly detection in the target system. The study focused on the mercury process system as the first use case and employed reconstruction-based anomaly detection on minutely sampled time series signals. The pipeline was integrated into the STAR platform to autonomously rank and flag anomalies every week. The STAR platform provides a user interface for the OSTs to evaluate the flagged anomalies, thereby incorporating human feedback.

Anomaly detection↗

Electrostatic imaging of encapsulated graphene

Devices made from two-dimensional (2D) materials such as graphene and transition metal dichalcogenides exhibit remarkable electronic properties of interest to many subdisciplines of nanoscience. Owing to their 2D nature, their quality is highly susceptible to contamination and degradation when exposed to the ambient environment. Protecting the 2D layers by encapsulation between hexagonal boron nitride (hBN) layers significantly improves their quality. Locating these samples within the encapsulant and assessing their integrity prior to further processing then becomes challenging. Here we show that conductive scanning probe techniques such as electrostatic force and Kelvin force microscopy make it possible to visualize the encapsulated layers, their charge environment and local defects on the sub-micrometer scale. Our techniques are employed without requiring electrical contact to the embedded layer, providing valuable feedback on the device's local electronic quality prior to any device etching or electrode deposition. We show that these measurement modes, which are simple extensions of atomic force microscopy, are perfectly suited for imaging encapsulated conductors and their local charge environments.

36 MATERIALS SCIENCE↗