Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “sample acquisition”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 865 records · Page 48

Performance of a Ka-band transponder breadboard for deep-space applications

This article summarizes the design concepts applied in the development of and advanced Ka-band (34.4 GHz/32 GHz) transponder breadboard for the next generation of space communications systems applications. The selected architecture upgrades the X-band (7.2 GHz/8.4 GHz) deep-space transponder (DST) to provide Da-band up/Ka- and X-band down capability. The Ka-band transponder breadboard incorporates several state-of-the-art components, including sampling mixers, a Ka-band dielectric resonator oscillator, and microwave monolithic integrated circuits (MMICs). The MMICs that were tested in the breadboard include upconverters, downconverters, automatic gain control circuits, mixers, phase modulators, and amplifiers. The measured receiver dynamic range, tracking range, acquisition rate, static phase error, and phase jitter characteristics of the Ka-band breadboard interfaced to the advanced engineering model X-band DST are in good agreement with the expected performance. The results show a receiver tracking threshold of -149 dBm with a dynamic range of 80 dB and a downlink phase jitter of 7 deg rms. The analytical results of phase noise and Allan standard deviation are in good agreement with the experimental results.

Mysoor, N. R.↗

Atmospheric Electron-induced X-Ray Spectrometer (AEXS) Instrument Development

Introduction: This paper describes the progress in data acquisition and establishing the observational capability of the AEXS instrument. The AEXS is a miniature instrument[1-4] based on the excitation of characteristic X-Ray Fluorescence (XRF) and luminescence spectra using a focused electron beam which enables nondestructive evaluation of sample surfaces in planetary ambient atmospheres. In situ operation is obtained through the use of a thin electron transmissive membrane to isolate the vacuum of the AEXS source from the outside ambient atmosphere. Thus eliminating the need for a vacuum pumped sample chamber as is common in all laboratory SEM s. The transmitted electrons impinge on the sample exciting XRF spectra from the irradiated spot on in-situ or collected samples with sub-mm to cm-scale spatial resolution at Mars atmospheric pressure. The AEXS system (Fig 1) consists of a high-energy (>10keV) electron gun encapsulated by the isolation membrane, an XRF detection and analyzer system, and a high voltage power supply. The XRF data are analyzed to determine the elemental abundance for the irradiated spots. The approach to demonstrating a proof of concept of the AEXS has been through 1) demonstrating the viability of microfabricated membranes, 2) assembling AEXS setups with increasingly integrated functional components, and 3) simulating the AEXS observational capabilities. The development of the instrument is described in detail in the poster paper[4] at this conference. This paper focuses on describing the progress of the AEXS instrument to acquire XRF data and using commercially available software to analyze the data streams and determine the accuracy, precision and resolution of the analysis compared to the certified elemental abundance.

Urgiles, E.↗

Glacier ice archives nearly 15,000-year-old microbes and phages

Background Glacier ice archives information, including microbiology, that helps reveal paleoclimate histories and predict future climate change. Though glacier-ice microbes are studied using culture or amplicon approaches, more challenging metagenomic approaches, which provide access to functional, genome-resolved information and viruses, are under-utilized, partly due to low biomass and potential contamination. Results We expand existing clean sampling procedures using controlled artificial ice-core experiments and adapted previously established low-biomass metagenomic approaches to study glacier-ice viruses. Controlled sampling experiments drastically reduced mock contaminants including bacteria, viruses, and free DNA to background levels. Amplicon sequencing from eight depths of two Tibetan Plateau ice cores revealed common glacier-ice lineages including Janthinobacterium, Polaromonas, Herminiimonas, Flavobacterium, Sphingomonas, and Methylobacterium as the dominant genera, while microbial communities were significantly different between two ice cores, associating with different climate conditions during deposition. Separately, ~355- and ~14,400-year-old ice were subject to viral enrichment and low-input quantitative sequencing, yielding genomic sequences for 33 vOTUs. These were virtually all unique to this study, representing 28 novel genera and not a single species shared with 225 environmentally diverse viromes. Further, 42.4% of the vOTUs were identifiable temperate, which is significantly higher than that in gut, soil, and marine viromes, and indicates that temperate phages are possibly favored in glacier-ice environments before being frozen. In silico host predictions linked 18 vOTUs to co-occurring abundant bacteria (Methylobacterium, Sphingomonas, and Janthinobacterium), indicating that these phages infected ice-abundant bacterial groups before being archived. Functional genome annotation revealed four virus-encoded auxiliary metabolic genes, particularly two motility genes suggest viruses potentially facilitate nutrient acquisition for their hosts. Finally, given their possible importance to methane cycling in ice, we focused on Methylobacterium viruses by contextualizing our ice-observed viruses against 123 viromes and prophages extracted from 131 Methylobacterium genomes, revealing that the archived viruses might originate from soil or plants. Conclusions Together, these efforts further microbial and viral sampling procedures for glacier ice and provide a first window into viral communities and functions in ancient glacier environments. Such methods and datasets can potentially enable researchers to contextualize new discoveries and begin to incorporate glacier-ice microbes and their viruses relative to past and present climate change in geographically diverse regions globally.

59 BASIC BIOLOGICAL SCIENCES↗

Analysis of Screen Channel LAD Bubble Point Tests in Liquid Oxygen at Elevated Temperature

The purpose of this paper is to examine the key parameters that affect the bubble point pressure for screen channel Liquid Acquisition Devices in cryogenic liquid oxygen at elevated pressures and temperatures. An in depth analysis of the effect of varying temperature, pressure, and pressurization gas on bubble point is presented. Testing of a 200 x 1400 and 325 x 2300 Dutch Twill screen sample was conducted in the Cryogenics Components Lab 7 facility at the NASA Glenn Research Center in Cleveland, Ohio. Test conditions ranged from 92 to 130K and 0.138 - 1.79 MPa. Bubble point is shown to be a strong function of temperature with a secondary dependence on pressure. The pressure dependence is believed to be a function of the amount of evaporation and condensation occurring at the screen. Good agreement exists between data and theory for normally saturated liquid but the model generally under predicts the bubble point in subcooled liquid. Better correlation with the data is obtained by using the liquid temperature at the screen to determine surface tension of the fluid, as opposed to the bulk liquid temperature.

Hartwig, Jason↗

Lunar Processing Cabinet 2.0: Retrofitting Gloveboxes into the 21st Century

In 2014, the Apollo 16 Lunar Processing Glovebox (cabinet 38) in the Lunar Curation Laboratory at NASA JSC received an upgrade including new technology interfaces. A Jacobs - Technology Innovation Project provided the primary resources to retrofit this glovebox into the 21st century. NASA Astromaterials Acquisition & Curation Office continues the over 40 year heritage of preserving lunar materials for future scientific studies in state-of-the-art facilities. This enhancement has not only modernized the contamination controls, but provides new innovative tools for processing and characterizing lunar samples as well as supports real-time exchange of sample images and information with the scientific community throughout the world.

Calaway, M. J.↗

Evaluation of an event-driven 3FI ASIC for spectroscopic X-ray detection with synchrotron radiation

The novel design and evaluation on the NSLS-II beamline of the 3FI application-specific integrated circuit (ASIC) bump-bonded to a simple, planar, 2D segmented silicon sensor are presented. The ASIC was developed for full-field fluorescence spectral X-ray imaging (3FI). It is a small-scale prototype that features a square array of 32 × 32 pixels, and the size of the pixels is 100 µm × 100 µm. The ASIC was implemented in a 65 nm CMOS integrated circuit fabrication process. Each pixel incorporates a charge-sensitive amplifier, a shaping filter, a discriminator, a peak detector and a sample-and-hold circuit, allowing detection of events and storage of signal amplitudes. The system operates in a frameless event-driven readout mode, outputting analog values for threshold-triggered events, allowing high-speed multi-element X-ray fluorescence data acquisition. The 3FI ASIC achieves per-channel spectrometric performance at a power consumption of only 200 µW per pixel, with nearly all dissipation confined to the analog front-end. An energy resolution is measured at the level of 308 eV full width at half-maximum (FWHM) at 8.04 keV (Cu Kα), and 138 eV FWHM at 3.69 keV (Ca Kα). This per-pixel capability makes the prototype suitable for in situ trace element microanalysis in biological and environmental studies. Moreover, the frameless architecture of the detector is designed to address limitations of conventional X-ray fluorescence microscopy, which typically requires mechanical scanning, by enabling continuous high-throughput data acquisition in future full-field implementations.

47 OTHER INSTRUMENTATION↗

Connect the Dots: In Situ 4-D Seismic Monitoring of CO 2 Storage With Spatio-Temporal CNNs

4-D seismic imaging has been widely used in CO 2 sequestration projects to monitor the fluid flow in the volumetric subsurface region that is not sampled by wells. Ideally, real-time monitoring and near-future forecasting would provide site operators with great insights to understand the dynamics of the subsurface reservoir and assess any potential risks. However, due to obstacles such as high deployment cost, availability of acquisition equipment, exclusion zones around surface structures, only very sparse seismic imaging data can be obtained during monitoring. That leads to an unavoidable and growing knowledge gap over time. The operator needs to understand the fluid flow throughout the project lifetime and the seismic data are only available at a limited number of times. This is insufficient for understanding reservoir behavior. To overcome those challenges, we have developed spatio-temporal neural-network-based models that can produce high-fidelity interpolated or extrapolated images effectively and efficiently. Specifically, our models are built on an autoencoder, and incorporate the long short-term memory (LSTM) structure with a new loss function regularized by optical flow. We validate the performance of our models using real 4-D post-stack seismic imaging data acquired at the Sleipner CO 2 sequestration field. We employ two different strategies in evaluating our models. Numerically, we compare our models with different baseline approaches using classic pixel-based metrics. We also conduct a blind survey and collect a total of 20 responses from domain experts to evaluate the quality of data generated by our models. Finally, via both numerical and expert evaluation, we conclude that our models can produce high-quality 2-D/3-D seismic imaging data at a reasonable cost, offering the possibility of real-time monitoring or even near-future forecasting of the CO 2 storage reservoir.

4-D seismic imaging↗

Heteronuclear single quantum coherence (HSQC) NMR spectra of lignin isolated from switchgrass residues after fermentation with milling

Here we present a curated dataset of two-dimensional heteronuclear single quantum coherence (HSQC) nuclear magnetic resonance (NMR) spectra of lignin isolated from a herbaceous energy crop (Panicum virgatum L.). The lowland variant “Timber” switchgrass from Ernst seeds was used. The switchgrass was knife milled and passed through a 2 mm sieve prior to consolidated bioprocessing (CBP) process. Switchgrass was suspended in Milli-Q water and autoclaved for 90 min on liquid cycles. The residues after autoclaving were then subjected to CBP using coculture of Clostridium thermocellum (C. thermocellum DSM 1313 (LL1004)) and Thermoanaerobacterium thermosaccarolyticum ( T. thermosaccharolyticum HG-8 ATCC 31960 (LL1244)). Once-fermented and twice-fermented (FF) switchgrass were subjected to ball and disc milling in bioreactors at 55 °C and 60, 48 grams/L solids loadings for primary and secondary fermentation respectively. When fermentations were completed, the residual solids were rinsed with milli-Q water. Lignin was isolated from the pretreated residues after ball-milling in a porcelain jar with ceramic balls via Retsch PM 200 at 600 rpm for 2 h followed by enzymatic hydrolysis in acetate buffer (pH 4.8, 50 °C) for 48 h. The dry lignin samples were dissolved in deuterated dimethyl sulfoxide (d6) and characterized using 13C–1H HSQC in a Bruker Avance III HD 500-MHz NMR spectrometer. A standard Bruker pulse sequence (hsqcetgpsisp.2) was used on a Prodigy platform cryoprobe. The spectra were acquired with the following acquisition conditions: 230 ppm spectral width in F1 (13C) dimension with 256 data points and 12 ppm spectral width in F2 (1H) dimension with 2048 data points, a 90° pulse, with a C–H coupling constant of 145 Hz, a 1.0 s pulse delay, and 64 scans. Spectra were processed using the Bruker TopSpin 3.6 software.

Lignin, HSQC, Switchgrass, CBP , Ball mill, Disc m↗

In situ spectroradiometric calibration of EREP imagery and estuarine and coastal oceanography of Block Island sound and adjacent New York coastal waters

The author has identified the following significant results. The first part of the study resulted in photographic procedures for making multispectral positive images which greatly enhance the color differences in land detail using an additive color viewer. An additive color analysis of the geologic features near Willcox, Arizona using enhanced black and white multispectral positives allowed compilation of a significant number of unmapped geologic units which do not appear on geologic maps of the area. The second part demonstrated the feasibility of utilizing Skylab remote sensor data to monitor and manage the coastal environment by relating physical, chemical, and biological ship sampled data to S190A, S190B, and S192 image characteristics. Photographic reprocessing techniques were developed which greatly enhanced subtle low brightness water detail. Using these photographic contrast-stretch techniques, two water masses having an extinction coefficient difference of only 0.07 measured simultaneously with the acquisition of S190A data were readily differentiated.

Yost, E. F.↗

A laser velocimeter system for large-scale aerodynamic testing

A unique laser velocimeter was developed that is capable of sensing two orthogonal velocity components from a variable remote distance of 2.6 to 10 m for use in the 40- by 80-Foot and 80- by 120-Foot Wind Tunnels and the Outdoor Aerodynamic Research Facility at Ames Research Center. The system hardware, positioning instrumentation, and data acquisition equipment are described in detail; system capabilities and limitations are discussed; and expressions for systematic and statistical accuracy are developed. Direct and coupled laboratory measurements taken with the system are compared with measurements taken with a laser velocimeter of higher spatial resolution, and sample data taken in the open circuit exhaust flow of a 1/50-scale model of the 80- by 120-Foot Wind Tunnel are presented.

Reinath, M. S.↗

A laser velocimeter system for the Ames 40- by 80-foot and 80by 120-foot wind tunnels

A unique laser velocimeter has been developed that is capable of sensing two orthogonal velocity components from a variable remote distance of 2.6 to 10 m for use in the Ames 40- by 80-Foot and 80- by 120-Foot wind tunnels, as well as in the Ames Outdoor Aerodynamic Research Facility. The system hardware, positioning instrumentation, and data acquisition equipment are described in detail. System capabilities and limitations are discussed, and expressions for systematic and statistical accuracy are developed. Direct and coupled laboratory measurements of a turbulent swirling flow are compared with measurements taken with a laser velocimeter of higher spatial resolution. Sample measurements taken in the open-circuit exhaust flow of the 80- by 120-Foot Wind Tunnel 1/50-scale model are presented.

Reinath, M. S.↗

Towards Diverse and Representative Global Pretraining Datasets for Remote Sensing Foundation Models

The design of a pretraining dataset is emerging as a critical component for the generality of foundation models. In the remote sensing realm, large volumes of imagery and benchmark datasets exist that can be leveraged to pretrain foundation models, however using this imagery in absence of a well-crafted sampling strategy is inefficient and has the potential to create biased and less generalizable models. Here, we provide a discussion and vision for the curation and assessment of pretraining datasets for remote sensing geospatial foundation models. We highlight the importance of geographic, temporal, and image acquisition diversity and review possible strategies to enable such diversity at global scale. In addition to these characteristics, support for various spatial-temporal pretext tasks within the dataset is also critical. Ultimately, our primary objective is to place emphasis on and draw attention to the data curation stage of the foundation model development pipeline. By doing so, we think it is possible to reduce biases of geospatial foundation models, as well as enable broader generalization to downstream remote sensing tasks and applications.

Arndt, Jacob↗

An Approach to Application of Multispectral Sensors, using AVIRIS Data

High spatial resolution multispectral/hyperspectral sensors are being developed by private industry with science/research customers as end users. With an increasingly wide range of sensor choices, it is important for the remote sensing science community and commercial community alike to understand the trade-offs between ground sample distance (GSD), spectral resolution, and signal-to-noise ratio (SNR) in selecting a sensor that will best meet their needs. High spatial resolution hyperspectral imagery and super resolution multispectral charge-coupled device imagery can be used to develop prototypes of proposed data acquisition systems without building new systems or collecting large sets of additional data. By using these datasets to emulate proposed and existing systems, imaging systems may be optimized to meet customer needs in a virtual environment. This approach also enables one to determine, a priori, whether an existing dataset will be useful for a given application.

Warner, Amanda↗

ASPRS Digital Imagery Guideline Image Gallery Discussion

The objectives of the image gallery are to 1) give users and providers a simple means of identifying appropriate imagery for a given application/feature extraction; and 2) define imagery sufficiently to be described in engineering and acquisition terms. This viewgraph presentation includes a discussion of edge response and aliasing for image processing, and a series of images illustrating the effects of signal to noise ratio (SNR) on images. Another series of images illustrates how images are affected by varying the ground sample distances (GSD).

Ryan, Robert↗

Hot Press Market Study

A study has been conducted to identify vendors for a hot press suitable for meeting program deliverables chiefly to achieve a higher TRL for the material and process. This study identities the high level specifications for the hot press which must be able to produce samples to support both the fabrication method development and fabricate full size components for testing to demonstrate success. Three vendors capable of meeting hot press specifications were contacted and estimates were obtained. A comparison of the equipment was performed and a recommendation is made for equipment acquisition.

36 MATERIALS SCIENCE↗

Instrumentation advances for transonic testing

New and improved instrumentation, like new and improved wind tunnels, provide capabilities which stimulate innovative research and discovery. During the past few years there have been a number of instrumentation developments which have aided and abetted the acquisition of more accurate aerodynamic data and have led to new physical insights as well. Some of these advances are reviewed, particularly in the area of thin film gages, hot wire anemometry, and laser instrumentation. A description is given of the instruments and/or techniques and some sample results are shown.

Bobbitt, Percy J.↗

Parallel Fin ORU Thermal Interface for space applications

The Parallel Fin Thermal Interface has been developed as an Orbital Replaceable Unit (ORU) interface. The interface transfers heat from an ORU baseplate to a Heat Acquisition Plate (HAP) through pairs of fins sandwiched between insert plates that press against the fins with uniform pressure. The insert plates are spread apart for ORU baseplate separation and replacement. Two prototype interfaces with different fin dimensions were built (Model 140 and 380). Interfacing surface samples were found to have roughnesses of 56 to 89 nm. Conductance values of 267 to 420 W/sq m C were obtained for the 140 model in vacuum with interface pressures of 131 to 262 kPa (19 to 38 psi). Vacuum conductances ranging from 176 to 267 W/sq m F were obtained for the 380 model at interface pressures of 97 to 152 kPa (14 and 22 psi). Correlations from several sources were found to agree with test data within 20 percent using thermal math models of the interfaces.

Stobb, C. A.↗

Atmospheric Electron-Induced X-Ray Spectrometer (AEXS) Development

This paper describes the progress in the development of the so-called Atmospheric Electron X-ray Spectrometer (AEXS) instrument in our laboratory at JPL. The AEXS is a novel miniature instrument concept based on the excitation of characteristic X-Ray Fluorescence (XRF) and luminescence spectra using a focused electron beam, for non-destructive evaluation of surfaces of samples in situ, in planetary ambient atmosphere. In situ operation is obtained through the use of a thin electron transmissive membrane to isolate the vacuum within the AEXS electron source from the outside ambient atmosphere. By using a focused electron beam, the impinging electrons on samples in the external atmosphere excite XRF spectra from the irradiated spots with high-to-medium spatial resolution. The XRF spectra are analyzed using an energy-dispersive detector to determine surface elemental composition. The use of high- intensity electron beam results in rapid spectrum acquisition (several minutes), and consequently low energy consumption (several tens of Joules) per acquired XRF spectrum in comparison to similar portable instruments.

X-ray fluorescence (XRF)↗