Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “pump efficiency”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 865 records · Page 48

Development and evaluation of a multi-functional heat pump with embedded thermal storage

We developed and tested a novel multi-functional packaged vertical heat pump designed for multi-family buildings, capable of providing space cooling, space heating, water heating, and energy storage integration. The system employs a 3-speed scroll compressor and supports energy-efficient cooling and heating across different ambient conditions, while utilizing both indoor and outdoor air sources for water heating. Key performance metrics include an integrated energy efficiency ratio of 18.0 for cooling, a heating seasonal performance factor of 10.0, and a coefficient of performance (COP) of 2.1 for heating in cold climates down to −15 ˚C. Additionally, the system delivers an annual water heating COP greater than 4.0, with outstanding performance in combined space cooling and water heating modes, achieving a total COP of 8.8 by recovering condenser waste heat. The heat pump also demonstrated thermal energy storage capabilities, integrating with phase change material systems to store heating and cooling energy. Furthermore, this versatile system offers a promising solution for improving energy efficiency and sustainability in multi-family buildings, providing high-performance heating, cooling, and water heating across a range of climates.

COP↗

A Comparison of Power Take-Off Architectures for Wave-Powered Reverse Osmosis Desalination of Seawater with Co-Production of Electricity

Several power take-off (PTO) architectures for wave-powered reverse osmosis (RO) desalination of seawater are introduced and compared based on the annual average freshwater production and the size of the components, which strongly relate to the costs of the system. The set of architectures compared includes a novel series-type PTO architecture not previously considered. These seawater hydraulic PTO architectures are composed of a WEC-driven pump, an RO module, an intake charge pump driven by an electric motor, and a hydraulic motor driving an electric generator for electric power production. This study is performed using an efficient two-way coupled steady-state model for the average performance of the system in a given sea state, including freshwater permeate production, electric power production, and electric power consumption. A multi-objective design problem is formulated for the purposes of this comparative study, with the objectives of maximizing annual freshwater production, minimizing the displacement of the WEC-driven pump, and minimizing the installed RO membrane area. This establishes a framework for comparison in the absence of a mature techno-economic model. The requirement that the system produces enough electric power to meet its consumption is applied as a constraint on the operation of the system. The oscillating wave surge converter Oyster 1 is assumed as the WEC. Weights on performance of the system in a given sea state are based on historical data from Humboldt Bay, CA. This study finds that (1) architectures in a series configuration allow for a reduction in the WEC-driven pump size of 59–92% compared to prior work, (2) varying the displacement of the WEC-driven pump between sea conditions does not provide any significant advantage in performance, and (3) varying the active RO membrane area between sea condition offers improvements between 7% and 41% in each design objective.

Energy & Fuels↗

A dynamic 2D Borehole Thermal Energy Storage (BTES) model for enhanced computational efficiency

Progressing toward a future increasingly reliant on renewable energy sources, the development of effective, durable energy storage solutions becomes essential to balance supply and demand fluctuations. Borehole Thermal Energy Storage (BTES) is a long-duration thermal energy storage technology that captures excess heat generated from renewable energy sources and stores it underground for later use, enabling the efficient utilization of sustainable energy. This approach is particularly valuable in district energy networks when integrated with Ground Source Heat Pumps (GSHP) to provide stable heating and cooling. However, traditional three-dimensional (3D) numerical models of BTES systems demand extensive computational resources, limiting their practicality for real-time and large-scale applications. This study introduces a novel two-dimensional (2D) modeling approach that reduces computational costs while maintaining high accuracy. By employing a radial ring-based discretization method, the model simulates heat injection, retention, and retrieval dynamics over seasonal cycles. A new thermal-mass weighted-average temperature parameter is introduced to evaluate the performance of BTES systems. Model validation against FEFLOW simulations demonstrates a 17-fold improvement in computational speed compared to traditional Computational Fluid Dynamics (CFD) models while achieving a mean absolute percentage error (MAPE) of 2 % during charging and 4 % during discharging. Additionally, a trade-off analysis between computational efficiency and accuracy is conducted, ensuring the model's applicability for real-world scenarios. The findings of this research contribute to the development of computationally efficient BTES models, facilitating better optimization, control, and integration into renewable energy systems. This work provides a foundation for further studies in techno-economic analysis, multi-year performance evaluation, and real-time operational strategies for BTES applications, supporting a more sustainable energy future.

2D modeling↗

Sandwich-Structured Photothermal Wood for Durable Moisture Harvesting and Pumping

Moisture capture coupled with photothermal regeneration provides an alternative and sustainable way to acquire fresh water. Composite moisture absorbents based on hygroscopic salts are environmentally friendly, economically feasible, and of high efficiency but suffer from the unavoidable desiccant leakage during absorption and evaporation-induced salt accumulation on material surfaces during desorption. Additionally, in this study, we develop a superhydrophobic–hydrophilic–hydrophobic photothermal wood embedded with CaCl 2 to promote the durability of the absorbents. The sandwich structure serves as a liquid/vapor gate allowing vapor transport but forbidding liquid permeation, enabling the condensation and evaporation within the wood. Beyond moisture harvesting, the sandwich-structured photothermal wood exhibits potential in indoor dehumidification by pumping the moisture through an absorption–desorption cycle.

36 MATERIALS SCIENCE↗

Regenerable Liquid Desiccants for High Efficiency Humidity Control in Microgravity

The NASA X-Hab project aims to design, manufacture, test, and prove functionality of an air humidity control subsystem to dehumidify and re-humidify air from a space cabin. The method of regulating cabin air humidity utilizes vortex phase separation, which uses an ionic liquid (IL) desiccant for air-water phase separation. This subsystem is intended to be integrated with a CO 2 removal system requiring de-humidified air to operate efficiently. The air humidity control subsystem is composed of a cold-desiccant or cold-side Vortex Phase Separator (VPS) that dehumidifies the cabin air. The dehumidified air exits the cold-side (CS) VPS chamber to flow into the CO 2 removal module, and the cold, water-laden liquid desiccant flows to a regenerative heat exchanger. From the heat exchanger the liquid desiccant continues to the heater. After heating, the desiccant flows into a hot-desiccant or hot-side (HS) VPS as the dehumidified air from CO 2 removal module enters through the HS VPS air inlet. The rehumidified air exits the HS VPS into the space cabin. One pump installed at the liquid exit of the CS VPS and one pump installed at the liquid exit of the HS VPS transport the fluid through the system. To evaluate the system’s efficiency and effectiveness, the temperature, pressure, flow rate and relative humidity are read, recorded, and analyzed at critical points along the module.

Gerardo Castro↗

Evaluation of active thermal control options for Space Station

An analysis of various Space Station (MSS) active thermal control systems options under consideration because of their potential low weight, efficiency and reliability is reported. The study addressed ordinary and diode-action body mounted radiators, thermal storage, the area and pumping power requirements for single-phase cooling of cold plates, and single-phase and two-phase active cooling loops. The base configuration considered was a core MSS formed by four habitable modules on which are mounted heat pipe radiators articulated to be always edge-on to the sun. A simulation was performed which accounted for the available heat sinks, several thermal loads and the heat rejection capability. No benefits were found with diode-action radiators if the solar absorption is 0.1 or less, although diode-action heat pipes will maintain a higher level of performance in the presence of coating degradation. Thermal storage becomes important only with radiator coating degradation. Water can be up to three times as efficient as Freon as a heat transfer medium. Finally, single-phase cooling offers a lower system mass than two-phase cooling if varying temperature heat loads can be accommodated.

Schuster, J. R.↗

A hierarchical gray-box dynamic modeling methodology for direct-expansion cooling systems to support control stability analysis; Méthodologie de modélisation dynamique hiérarchique de type boîte grise pour les systèmes de refroidissement à détente directe afin de soutenir l'analyse de stabilité de la commande

In this paper, a gray-box dynamic modeling approach for direct-expansion cooling systems is presented. The overall approach incorporates a multi-stage training procedure that consists of 1) identification of component sub-models from quasi-steady-state performance data, 2) system model integration with estimation of refrigerant charge and 3) fine tuning of thermal capacitances of the evaporator and condenser to capture the system dynamic responses. Compared to traditional physics-based models, the proposed modeling approach has advantages including reduced engineering efforts in the model development phase, improved computational efficiency and enhanced prediction accuracy. The modeling method was validated using a 3-ton variable-speed heat pump and proved to be capable of accurately predicting the system transient behaviors over a wide range of operating conditions. The established dynamic model was then applied for control stability analysis, with a specific goal of determining a proper control execution time step. The case study results showed that the stable control execution time step could change significantly, from 3 sec to 19 sec, as the operating conditions and control settings vary, and a proper selection of the execution time step is critical to ensure stable and reliable operations.

42 ENGINEERING↗

Conceptual Design for a Blanket Tritium Extraction Test Stand

Future fusion reactors must be able to breed the tritium they will consume. Several breeding and tritium extraction technologies are under investigation internationally. PbLi is of particular interest as a breeder material. A new forced convection PbLi loop, the Tritium Extraction eXperiment (TEX), is being designed and constructed to investigate tritium extraction from PbLi. Specifically, TEX will serve to investigate the extraction efficiency of various vacuum permeator membranes and configurations. The major components of the loop include a moving magnet pump, reverse permeator, furnace test section, analysis chamber, supply tank, and plenum. As significant hazards are present in such experiments, safety is an integral focus of the experimental design.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Joule-class THz pulses from microchannel targets

Inference of joule-class THz radiation sources from microchannel targets driven with hundreds of joule, picosecond lasers is reported. Here, THz sources of this magnitude are useful for nonlinear pumping of matter and for charged-particle acceleration and manipulation. Microchannel targets demonstrate increased laser–THz conversion efficiency compared to planar foil targets, with laser energy to THz energy conversion up to ~0.9% in the best cases.

47 OTHER INSTRUMENTATION↗

Design, manufacture, and test of coolant pump-motor assembly for Brayton power conversion system

The design, development, fabrication, and testing of seven coolant circulating pump-motor assemblies are discussed. The pump-motor assembly is driven by the nominal 44.4-volt, 400-Hz, 3-phase output of a nominal 56-volt dc input inverter. The pump-motor assembly will be used to circulate Dow Corning 200 liquid coolant for use in a Brayton cycle space power system. The pump-motor assembly develops a nominal head of 70 psi at 3.7 gpm with an over-all efficiency of 26 percent. The design description, drawings, photographs, reliability results, and developmental and acceptance test results are included.

Gabacz, L. E.↗

Nuclear-pumped gas lasers

Laser pumping incorporates use of volumetric helium isotope reaction. Reaction deposits energy nearly uniformly throughout laser volume. Method improves efficiency of system as compared with conventional coating method.

Aohl, F.↗

A Conceptual Design Study on the Application of Liquid Metal Heat Transfer Technology to the Solar Thermal Power Plant

Alkali metal heat transfer technology was used in the development of conceptual designs for the transport and storage of sensible and latent heat thermal energy in distributed concentrator, solar Stirling power conversion systems at a power level of 15 kWe per unit. Both liquid metal pumped loop and heat pipe thermal transport were considered; system configurations included: (1) an integrated, focal mounted sodium heat pipe solar receiver (HPSR) with latent heat thermal energy storage; (2) a liquid sodium pumped loop with the latent heat storage, Stirling engine-generator, pump and valves located on the back side of the concentrator; and (3) similar pumped loops serving several concentrators with more centralized power conversion and storage. The focus mounted HPSR was most efficient, lightest and lowest in estimated cost. Design confirmation testing indicated satisfactory performance at all angles of inclination of the primary heat pipes to be used in the solar receiver.

Zimmerman, W. F.↗

Drilling Holes in Graphite/Epoxy Composites

Slurry of silicon carbide powder in water fed onto bit while drilling. Slurry contains about 60 percent silicon carbide by weight. Slurry recirculated by low-power pump. With slurry, dull tools cut as fast as, or faster than, sharp ones. Holes drilled rapidly and efficiently regardless of ply orientation; whether unidirectional, quasi-isotropic symmetrical, or cross-ply.

Daniels, J. G.↗

High heat transfer oxidizer heat exchanger design and analysis

The RL10-2B engine, a derivative of the RL10, is capable of multimode thrust operation. This engine operates at two low thrust levels: tank head idle (THI), which is approximately 1 to 2% of full thrust, and pumped idle (PI), which is 10% of full thrust. Operation at THI provides vehicle propellant settling thrust and efficient engine thermal conditioning; PI operation provides vehicle tank pre-pressurization and maneuver thrust for low-g deployment. Stable combustion of the RL10-2B engine during the low thrust operating modes can be accomplished by using a heat exchanger to supply gaseous oxygen to the propellant injector. The oxidizer heat exchanger (OHE) vaporizes the liquid oxygen using hydrogen as the energy source. The design, concept verification testing and analysis for such a heat exchanger is discussed. The design presented uses a high efficiency compact core to vaporize the oxygen, and in the self-contained unit, attenuates any pressure and flow oscillations which result from unstable boiling in the core. This approach is referred to as the high heat transfer design. An alternative approach which prevents unstable boiling of the oxygen by limiting the heat transfer is referred to as the low heat transfer design and is reported in Pratt & Whitney report FR-19135-2.

Kmiec, Thomas D.↗

Free-flying experiment to measure the Schawlow-Townes linewidth limit of a 300 THz laser oscillator

Recent advances in laser diode-pumped solid state laser sources permit the design and testing of laser sources with linewidths that approach the Schawlow-Townes limit of 1 Hz/mW of output power. Laser diode pumped solid state ring oscillators have been operated with CW output power levels of 25 mW at electrical efficiencies that exceed 6 percent. These oscillators are expected to operate for lifetimes that approach those of the laser diode sources which is now approaching 20,000 hours. The efficiency and lifetime of these narrow linewidth laser sources will enable space measurements of gravity waves, remote sensing applications (including local range rate and measurements), and laser sources for frequency and time standards. A free-flight experiment, 'SUNLITE', is being designed to measure the linewidth of this all-solid-state laser system.

Byer, R. L.↗

From diffusion pumps to cryopumps: The conversion of GSFC's space environment simulator

The SES (Space Environmental Simulator), largest of the Thermal Vacuum Facilities at The Goddard Space Flight Center, recently was converted from an oil diffusion pumped chamber to a Cryopumped chamber. This modification was driven by requirements of flight projects. The basic requirement was to retain or enhance the operational parameters of the chamber such as pumping speed, ultimate vacuum, pump down time, and thermal system performance. To accomplish this task, seventeen diffusion pumps were removed and replaced with eight 1.2 meter (48 inch) diameter cryopumps and one 0.5 meter (20 inch) turbomolecular pump. The conversion was accomplished with a combination of subcontracting and in-house efforts to maximize the efficiency of implementation.

Cary, Ron↗

Mechanical design and stress analysis challenges overcome to ensure the structural integrity of Europa Clipper's mechanical pumped fluid loop Heat Redistribution System (HRS)

Launching in 2023, NASA’s Europa Clipper mission will place a spacecraft into a long, looping orbit around Jupiter to perform a series of close flyby investigations of its moon Europa. Strong evidence suggests that Europa hosts an ocean of liquid water beneath its icy crust that could harbor conditions favorable for life. The spacecraft is currently under development by the Jet Propulsion Laboratory (JPL) and the Applied Physics Laboratory (APL) and nearing completion of its Detailed Design Phase. A Mechanical Pumped Fluid Loop (MPFL) architecture known as the Heat Redistribution System (HRS) has been baselined to provide power efficient thermal control of the sensitive components within the Avionics, Radio Frequency (RF), and Propulsion Modules. Principally, the HRS harvests waste heat from the onboard dissipating equipment and distributes it to a 1.4 m diameter by 3 m tall cylindrical structure that cocoons and keeps the propulsion subsystem warm. Numerous technical issues had to be resolved in order to securely attach nearly 100 m of HRS tubing to the spacecraft, which is predicted to experience high launch loads. This paper will review the relevant environments and mission constraints as well as outline the stress and fatigue analysis approach taken to verify the detailed mechanical design of the HRS.

Kolenz, Daniel↗