Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “precision timing applications”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 865 records · Page 48

Imagery Integration Team

The Human Exploration Science Office (KX) provides leadership for NASA's Imagery Integration (Integration 2) Team, an affiliation of experts in the use of engineering-class imagery intended to monitor the performance of launch vehicles and crewed spacecraft in flight. Typical engineering imagery assessments include studying and characterizing the liftoff and ascent debris environments; launch vehicle and propulsion element performance; in-flight activities; and entry, landing, and recovery operations. Integration 2 support has been provided not only for U.S. Government spaceflight (e.g., Space Shuttle, Ares I-X) but also for commercial launch providers, such as Space Exploration Technologies Corporation (SpaceX) and Orbital Sciences Corporation, servicing the International Space Station. The NASA Integration 2 Team is composed of imagery integration specialists from JSC, the Marshall Space Flight Center (MSFC), and the Kennedy Space Center (KSC), who have access to a vast pool of experience and capabilities related to program integration, deployment and management of imagery assets, imagery data management, and photogrammetric analysis. The Integration 2 team is currently providing integration services to commercial demonstration flights, Exploration Flight Test-1 (EFT-1), and the Space Launch System (SLS)-based Exploration Missions (EM)-1 and EM-2. EM-2 will be the first attempt to fly a piloted mission with the Orion spacecraft. The Integration 2 Team provides the customer (both commercial and Government) with access to a wide array of imagery options - ground-based, airborne, seaborne, or vehicle-based - that are available through the Government and commercial vendors. The team guides the customer in assembling the appropriate complement of imagery acquisition assets at the customer's facilities, minimizing costs associated with market research and the risk of purchasing inadequate assets. The NASA Integration 2 capability simplifies the process of securing one-of-a-kind imagery assets and skill sets, such as ground-based fixed and tracking cameras, crew-in the-loop imaging applications, and the integration of custom or commercial-off-the-shelf sensors onboard spacecraft. For spaceflight applications, the Integration 2 Team leverages modeling, analytical, and scientific resources along with decades of experience and lessons learned to assist the customer in optimizing engineering imagery acquisition and management schemes for any phase of flight - launch, ascent, on-orbit, descent, and landing. The Integration 2 Team guides the customer in using NASA's world-class imagery analysis teams, which specialize in overcoming inherent challenges associated with spaceflight imagery sets. Precision motion tracking, two-dimensional (2D) and three-dimensional (3D) photogrammetry, image stabilization, 3D modeling of imagery data, lighting assessment, and vehicle fiducial marking assessments are available. During a mission or test, the Integration 2 Team provides oversight of imagery operations to verify fulfillment of imagery requirements. The team oversees the collection, screening, and analysis of imagery to build a set of imagery findings. It integrates and corroborates the imagery findings with other mission data sets, generating executive summaries to support time-critical mission decisions.

Calhoun, Tracy↗

Identification of Health Events in Astronaut Missions Using Longitudinal Molecular Signature Detection

Individualized health monitoring can now incorporate a precision medicine approach, profiling multiple molecular and physiological measures of health (generalized omics) longitudinally to enable the timely diagnosis and treatment of disease. Such measurements can include blood chemistries, gene expression data, metabolite measurements, and digital device data. We will present our work on extending such an approach to monitoring individual astronaut health for deep space missions. We have developed and implemented novel algorithms to monitor and detect physiolgical state departures from individualized healthy astronaut baselines , utilizing and biologically annotating generalized omics. Our new methods can detect baseline deviations across omics corresponding to potentially adverse medical events. Events pointing to changes in individual health are then compared across individuals to identify common responses and detect changes affecting multiple crewmembers. We show the utility of our methods in detecting temporal health changes across subjects using retrospective Earth and astronaut mission data (metabolite and immune marker data across multiple missions), in order for this technique t o be applicable for future missions.

G I Mias↗

Spatially Precise Light‐Activated Dedoping in Wafer‐Scale MoS 2 Films

2D materials, particularly transition metal dichalcogenides (TMDCs), have shown great potential for microelectronics and optoelectronics. However, a major challenge in commercializing these materials is the inability to control their doping at a wafer scale with high spatial fidelity. Interface chemistry is used with the underlying substrate oxide and concomitant exposure to visible light in ambient conditions for photo-dedoping wafer scale MoS 2 . It is hypothesized that the oxide layer traps photoexcited holes, leaving behind long-lived electrons that become available for surface reactions with ambient air at sulfur vacancies (defect sites) resulting in dedoping. Additionally, high fidelity spatial control is showcased over the dedoping process, by laser writing, and fine control achieved over the degree of doping by modulating the illumination time and power density. This localized change in MoS 2 doping density is very stable (at least 7 days) and robust to processing conditions like high temperature and vacuum. The scalability and ease of implementation of this approach can address one of the major issues preventing the “Lab to Fab” transition of 2D materials and facilitate its seamless integration for commercial applications in multi-logic devices, inverters, and other optoelectronic devices.

14 SOLAR ENERGY↗

Directing Nanoparticle Organization in Response to Diverse Chemical Inputs

Signaling cascades are crucial for transducing stimuli in biological systems, enabling multiple stimuli to regulate a downstream target with precisely controlled timing and amplifying signals through a series of intermediary reactions. Developing a robust signaling system with such capabilities would be pivotal for programming complex behaviors in synthetic DNA-based molecular devices. However, although “software” such as nucleic acid circuits could potentially be harnessed to relay signals to DNA-based nanostructure hardware, such explorations have been limited. Here, in this study, we develop a platform for transducing a variety of stimuli via messenger-mediated reactions to regulate the release and reloading of gold nanoparticles (AuNPs) in a 3D DNA framework. In the first step, an in vitro transcription circuit is engineered to sense and amplify chemical stimuli, including arbitrary DNA sequences and proteins, producing RNA. In the second step, the RNA releases the DNA-coated AuNPs from the DNA framework via a strand displacement reaction. AuNP reloading is controlled by a separate step driven by degradation of the RNA. Our platform holds promise for applications requiring dynamic multiagent control over DNA-based devices, offering a versatile tool for advanced molecular device engineering.

36 MATERIALS SCIENCE↗

Single‐Domain Multiferroic Array‐Addressable Terfenol‐D (SMArT) Micromagnets for Programmable Single‐Cell Capture and Release

Abstract Programming magnetic fields with microscale control can enable automation at the scale of single cells ≈10 µm. Most magnetic materials provide a consistent magnetic field over time but the direction or field strength at the microscale is not easily modulated. However, magnetostrictive materials, when coupled with ferroelectric material (i.e., strain‐mediated multiferroics), can undergo magnetization reorientation due to voltage‐induced strain, promising refined control of magnetization at the micrometer‐scale. This work demonstrates the largest single‐domain microstructures (20 µm) of Terfenol‐D (Tb 0.3 Dy 0.7 Fe 1.92 ), a material that has the highest magnetostrictive strain of any known soft magnetoelastic material. These Terfenol‐D microstructures enable controlled localization of magnetic beads with sub‐micrometer precision. Magnetically labeled cells are captured by the field gradients generated from the single‐domain microstructures without an external magnetic field. The magnetic state on these microstructures is switched through voltage‐induced strain, as a result of the strain‐mediated converse magnetoelectric effect, to release individual cells using a multiferroic approach. These electronically addressable micromagnets pave the way for parallelized multiferroics‐based single‐cell sorting under digital control for biotechnology applications.

Khojah, Reem↗

Development of Hydroxyl Tagging Velocimetry for Low Velocity Flows

Hydroxyl tagging velocimetry (HTV) is a molecular tagging technique that relies on the photo-dissociation of water vapor into OH radicals and their subsequent tracking using laser induced fluorescence. Velocities are then obtained from time-of-flight calculations. At ambient temperature in air, the OH species lifetime is relatively short (<50 μs), making it suited for high speed flows. Lifetime and radicals formation increases with temperature, which allows HTV to also probe low-velocity, high-temperature flows or reacting flows such as flames. The present work aims at extending the domain of applicability of HTV, particularly towards low-speed (<10 m/s) and moderate (<500 K) temperature flows. Results are compared to particle image velocimetry (PIV) measurements recorded in identical conditions. Single shot and averaged velocity profiles are obtained in an air jet at room temperature. By modestly raising the temperature (100-200 degC) the OH production increases, resulting in an improvement of the signal-to-noise ratio (SNR). Use of nitrogen - a non-reactive gas with minimal collisional quenching - extends the OH species lifetime (to over 500 μs), which allows probing of slower flows or, alternately, increases the measurement precision at the expense of spatial resolution. Instantaneous velocity profiles are resolved in a 100degC nitrogen jet (maximum jet-center velocity of 6.5 m/s) with an uncertainty down to 0.10 m/s (1.5%) at 68% confidence level. MTV measurements are compared with particle image velocimetry and show agreement within 2%.

Andre, Matthieu A.↗

Celestial Mapping System for Lunar Surface Mapping and Analytics

Celestial Mapping System (CMS) is a software platform to generate virtual 3D globe for celestial bodies within our solar system. Various layers are built on top of the virtual globe to provide visualization of high resolution imagery, enable precise measurements, build analytical capabilities and broad range of functionalities to assist planetary scientists and mission planners. CMS is built using OpenJDK 11 and will run on a wide variety of platforms such as Linux, Windows, OSX, etc. It has a thick client with less overhead to access hardware resources. This allows features such as terrain profiling and distance calculations to be performed on the client and on the fly. The present focus of CMS is on developing lunar mapping tool kits to provide features such as - 3D first person view with zoom and navigational capabilities, realistic terrain visualization based on LRO data, measurement tools, Apollo landing site annotations, stereoscopic view, elevation profiles, line of sight analysis and many more. The application is developed to provide situational and domain awareness on Lunar surface, planning capabilities for equipment placements and traverse path optimization. As data becomes available, CMS has the capabilities to integrate data sets that change dynamically in real-time, which will be useful for monitoring satellites and remotely-sensed data on Lunar surface. CMS utilizes NASA WorldWind Java library and OpenGL to achieve high-performance rendering of data and measurements, and also adheres to OGC standards. CMS supports importing synthetic features in a variety of 3D, 2D, vector and raster formats. Nomenclature is pulled from USGS Moon IAU2000 database, and lunar parameters are based of the standardized IAU2000 Moon ellipsoid. GDAL (Geospatial Data Abstraction Library) was used to modify and test the accuracy of datasets before integrating into the application. Our high-resolution global elevation model was compared with the LRO LOLA DEM elevation values and tested to ensure accuracy. Celestial Mapping System has several potential use cases for NASA including subsurface lava tubes visualization and analysis, soil analysis, resource visualization and representation on 3D globe.

GIS system↗

Photometric Redshifts for Next-Generation Surveys

Photometric redshifts are essential in studies of both galaxy evolution and cosmology, as they enable analyses of objects too numerous or faint for spectroscopy. The Rubin Observatory, Euclid, and Roman Space Telescope will soon provide a new generation of imaging surveys with unprecedented area coverage, wavelength range, and depth. To take full advantage of these data sets, further progress in photometric redshift methods is needed. In this review, we focus on the greatest common challenges and prospects for improvement in applications of photometric redshifts to the next generation of surveys: ∙ Gains in performance (i.e., the precision of redshift estimates for individual galaxies) could greatly enhance studies of galaxy evolution and some probes of cosmology. ∙ Improvements in characterization (i.e., the accurate recovery of redshift distributions of galaxies in the presence of uncertainty on individual redshifts) are urgently needed for cosmological measurements with next-generation surveys. To achieve both of these goals, improvements in the scope and treatment of the samples of spectroscopic redshifts that make high-fidelity photometric redshifts possible will also be needed. For the full potential of the next generation of surveys to be reached, the characterization of redshift distributions must improve by roughly an order of magnitude compared with the current state of the art, requiring progress on a wide variety of fronts. We conclude by presenting a speculative evaluation of how photometric redshift methods and the collection of the necessary spectroscopic samples may improve by the time near-future surveys are completed.

Astronomy & Astrophysics↗

Development of visual 3D virtual environment for control software

Virtual environments for software visualization may enable complex programs to be created and maintained. A typical application might be for control of regional electric power systems. As these encompass broader computer networks than ever, construction of such systems becomes very difficult. Conventional text-oriented environments are useful in programming individual processors. However, they are obviously insufficient to program a large and complicated system, that includes large numbers of computers connected to each other; such programming is called 'programming in the large.' As a solution for this problem, the authors are developing a graphic programming environment wherein one can visualize complicated software in virtual 3D world. One of the major features of the environment is the 3D representation of concurrent process. 3D representation is used to supply both network-wide interprocess programming capability (capability for 'programming in the large') and real-time programming capability. The authors' idea is to fuse both the block diagram (which is useful to check relationship among large number of processes or processors) and the time chart (which is useful to check precise timing for synchronization) into a single 3D space. The 3D representation gives us a capability for direct and intuitive planning or understanding of complicated relationship among many concurrent processes. To realize the 3D representation, a technology to enable easy handling of virtual 3D object is a definite necessity. Using a stereo display system and a gesture input device (VPL DataGlove), our prototype of the virtual workstation has been implemented. The workstation can supply the 'sensation' of the virtual 3D space to a programmer. Software for the 3D programming environment is implemented on the workstation. According to preliminary assessments, a 50 percent reduction of programming effort is achieved by using the virtual 3D environment. The authors expect that the 3D environment has considerable potential in the field of software engineering.

Hirose, Michitaka↗

Hierarchical Approach to 'Atomistic' 3-D MOSFET Simulation

We present a hierarchical approach to the 'atomistic' simulation of aggressively scaled sub-0.1 micron MOSFET's. These devices are so small that their characteristics depend on the precise location of dopant atoms within them, not just on their average density. A full-scale three-dimensional drift-diffusion atomistic simulation approach is first described and used to verify more economical, but restricted, options. To reduce processor time and memory requirements at high drain voltage, we have developed a self-consistent option based on a solution of the current continuity equation restricted to a thin slab of the channel. This is coupled to the solution of the Poisson equation in the whole simulation domain in the Gummel iteration cycles. The accuracy of this approach is investigated in comparison to the full self-consistent solution. At low drain voltage, a single solution of the nonlinear Poisson equation is sufficient to extract the current with satisfactory accuracy. In this case, the current is calculated by solving the current continuity equation in a drift approximation only, also in a thin slab containing the MOSFET channel. The regions of applicability for the different components of this hierarchical approach are illustrated in example simulations covering the random dopant-induced threshold voltage fluctuations, threshold voltage lowering, threshold voltage asymmetry, and drain current fluctuations.

Asenov, Asen↗

Precise control of flexible manipulators

The design and experimental testing of end point position controllers for a very flexible one link lightweight manipulator are summarized. The latest upgraded version of the experimental set up, and the basic differences between conventional joint angle feedback and end point position feedback are described. A general procedure for application of modern control methods to the problem is outlined. The relationship between weighting parameters and the bandwidth and control stiffness of the resulting end point position closed loop system is shown. It is found that joint rate angle feedback in addition to the primary end point position sensor is essential for adequate disturbance rejection capability of the closed loop system. The use of a low order multivariable compensator design computer code; called Sandy is documented. A solution to the problem of control mode switching between position sensor sets is outlined. The proof of concept for endpoint position feedback for a one link flexible manipulator was demonstrated. The bandwidth obtained with the experimental end point position controller is about twice as fast as the beam's first natural cantilevered frequency, and comes within a factor of four of the absolute physical speed limit imposed by the wave propagation time of the beam.

Cannon, R. H., Jr.↗

Single particle – MC-ICP-MS for isotopic analysis of uranium particles

Single particle – multi-collector – inductively coupled plasma – mass spectrometry (SP-MC-ICP-MS) was employed to measure a suspension of 1 µm U3O8 particles (∼1.3 pg total U/particle) to determine their individual isotopic compositions of 234U/238U, 235U/238U, and 236U/238U. The effects of different detector combinations for 235U and 238U, including secondary electron multipliers (SEM) and Faraday detectors (1011 and 1013 Ω amplifiers), were explored for accuracy and precision optimization on the observed 235U/238U. The minor isotopic ratios (i.e., 234U/238U and 236U/238U) were analyzed such that the 234U and 236U were monitored on SEM detectors and the 238U was monitored on a Faraday (1011 Ω) detector. Various integration times (5, 10, 25, and 50 ms) were investigated in all detector configurations to gain a better understanding of their impact on sensitivity, accuracy, and precision. For 235U/238U ratios of 1 µm U3O8 particles, a dual Faraday detector measurement with 1011 Ω was the optimal choice; measurement of 1021 particles yielded an average 235U/238U ratio of 0.00170 (14), a −1.8% relative difference (% RD) from the reference value. The minor isotopic compositions were determined to be 0.0000070 (14) and 0.0000758 (48) for the 234U/238U and 236U/238U, respectively. These measurements correspond to <8% and <1% RD from their reference value for the 234U/238U and 236U/238U, respectively. SP-MC-ICP-MS was also able to provide insight into measurement sensitivity. In these individual particles, merely 15 and 165 atto-grams (ag) of 234U and 236U were present (calculated). Initial limits of detection for SP-MC-ICP-MS were determined to be ∼1.0 ag (when measured via SEM detectors). This valuable approach is applicable to areas including nuclear forensics, nuclear safeguards, and geochemical analysis, which require high-precision measurements of uranium within micron-sized particles.

Manard, Benjamin [ORNL] (ORCID:0000000207400627)↗

Endurance test of a 30-CM-diameter engineering model ion thruster. Task 12: Investigation of thin-film erosion monitors for ion thrusters

An investigation of short term measurement techniques for predicting the wearout of ion thrusters resulting from sputter erosion damage is described. The previously established laminar thin film techniques to provide high precision erosion rate data. However, the erosion rates obtained using this technique are generally substantially higher than those obtained during long term endurance tests (by virtue of the as deposited nature of the thin films), so that the results must be interpreted in a relative sense. Absolute measurements can be performed using a new masked substrate arrangement which was developed during this study. This new technique provides a means for estimating the lifetimes of critical discharge chamber components based on direct measurements of sputter erosion depths obtained during short duration (10 hour) tests. The method enables the effects on lifetime of thruster design and operating parameters to be inferred without the investment of the time and capital required to conduct long term (1000 hour) endurance tests. Results obtained using the direct measurement technique are shown to agree with sputter erosion depths calculated for the plasma conditions of the test and also with lifetest results. The direct measurement approach is shown to be applicable to both mercury and argon discharge plasma environments and should be useful in estimating the lifetimes of inert gas and extended performance mercury ion thrusters presently under development.

Beattie, J. R.↗

Abernathy's Lap

A lap in this instance is not a midriff but a tool for presision.polishing and grinding. During the Saturn V moonbooster program, Marshall Space Flight Center found a need for a better lap. The need arose from the exquisitely precise tolerances required for parts of the launch vehicle's guidance,and control system. So William J. Abernathy, a former Marshall employee, built a better lap; he invented a method for charging aluminum lap plates with diamond powder, then hard-anodizing them. The resulting lap produces a high polish on materials ranging from the softest aluminum to the hardest ceramics. It operates faster, wears longer and requires less reworking. Abernathy got NASA's permission to obtain a personal patent and he formed the one-man Abernathy Laps Co. in Huntsville, which produces a variety of laps. One of Abernathy's customers is Bell Aerospace Textron, Buffalo, which uses the laps to finish polish delicate instrument parts produced for NASA's Viking and other space programs. Says a Bell official: "Time needed (with the Abernathy lap) is a fraction of that required by conventional methods. The result is extremely accurate flatness and surface finish." Abernathy is providing laps for other manufacturing applications and for preparation of metallurgical specimens. The business is small but steady, and Abernathy plans expansion into other markets.

Source record↗

Alignment-Insensitive Lower-Cost Telescope Architecture

This architecture features an active wavefront sensing and control scheme along with methods for measuring the relative positions of the primary to aft optics, such as the secondary mirror, and should enable larger and cheaper telescope architectures needed for future applications. A wavefront source/sensor is placed at the center of curvature of the primary mirror. The system provides continuous light onto a primary mirror that is retro-reflected onto itself. This allows the wavefront controller to constantly update the positions of the primary mirror segments (or deformable mirror actuators). Another function of this innovation involves using a concave mirror on the back of the secondary mirror (or other aft optic) that has the same center-of-curvature location (in defocus) as the primary mirror. The two return beams can be aligned next to each other on a detector, or radially on top of each other. This provides a means with which to measure the relative position of the primary to the secondary (or other aft optics), thus allowing for the removal of misalignment of the center-of-curvature source/sensor (meaning it doesn't need precision placement) and also provides a means with which to monitor the relative alignment over time. This innovation does not require extremely good thermal stability on the primary mirror and can thus be used in any thermal environment and with cheaper materials. In addition to this, the architecture lets one phase (or align) the primary mirror independent of whether a star or scene is in the field. The segmented, spherical primary allows for cost-effective three-meter class (e.g. Midex and Discovery) missions as well as enabling 30-meter telescope solutions that can be manufactured in a reasonable amount of time. The continuous wavefront sensing and control architecture enables missions for low-Earth-orbit.

Feinberg, Lee↗

Gantryless Associated-Particle Neutron Radiography

The present work reports on the development of techniques for in-field fast-neutron radiography measurements using the associated-particle imaging (API) method. The API method employs alpha-neutron coincidences from the d+t→α+n reaction to enable fast neutron transmission imaging with excellent contrast using a wide cone beam. However, for field radiography applications, the API method is burdened by the need for the relative positions of the source and detector to be known. Fortunately, these relative positions can be inferred from transmission data. The inferred positions also enable accurate stitching of multiple images into a composite image even when using a low-resolution detector panel and acquiring images having few overlapping pixels. The developed techniques address analysis of measurements where (1) the source and detector panel are separately hand positioned rather than held in registration by a gantry, (2) multiple detector panel positions within the “coincident cone” of tagged neutrons are required to piece together an image of an item of interest, and (3) normalization measurements that have identical source-detector positioning but without the inspected object are not possible. The present work will describe the system calibrations (including timing calibrations and neutron direction calibrations) necessary for subsequent analyses, the method of locating the detector in the coincident cone of neutrons with millimeter precision using the timing and directions of coincident neutrons, the method of calculating a normalization image for a given detector panel position, and the method used to project multiple images into a common image.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ferrite Specification for the Mu2e 300 kHz and 4.4 MHz AC Dipole Magnets

The Mu2e experiment at Fermilab will measure the rate for neutrinoless-conversion of negative muons into electrons with never-before-seen precision. This experiment will use a pulsed 8 GeV proton beam with pulses separated by 1.7 µs. To suppress beam induced backgrounds to this process, a set of dipoles operating at 300 kHz and 4.4 MHz have been developed that will reduce the fraction of out-of-time protons at the level of 1E-10 or less. Selection of magnetic ferrite material for construction must be carefully considered given the high repetition rate and duty cycle that can lead to excess heating in conventional magnetic material. A model of the electromagnetic and thermal properties of candidate ferrite materials has been constructed. Magnetic permeability, inductance, and power loss were measured at the two operating frequencies in toroidal ferrite samples as well as in the ferrites from which prototype magnets were built. Additionally, the outgassing rates of the ferrite material was measured to determine vacuum compatibility. The outcome of this work is a detailed specification of the electrical and mechanical details of the ferrite material required for this application.

43 PARTICLE ACCELERATORS↗

Ground-Based GPS as a Calibration/Validation Tool for Tropospheric Sensing Instruments

The tropospheric sensing capabilities of ground-based GPS have been the subject of intensive validation efforts in recent years. But a maturing GPS technology is now rapidly becoming a valuable calibration/validation tool in its own right. We will describe two applications where ground-based GPS receivers have been used as a calibration/validation tool. The first such case is the Cassini gravitational wave media calibration project. A water vapor radiometer (WVR) will calibrate the telemetry signal from the Cassini spacecraft for line-of-sight wet tropospheric fluctuations. The demanding mission specifications require that the WVR's retrieval of wet delay from measurements of brightness temperature be precisely calibrated. We will describe the results from a special campaign to calibrate the WVR's retrieval algorithm with GPS. The second case involves the Topex/Poseidon microwave radiometer (TMR) which is used to calibrate the altimetric measurement for the effect of tropospheric water vapor. Using GPS data from 1992 to 1997 we detected an anomalous drift in columnar water vapor measurements from the TMR. The TMR's spurious drift implies that the uncalibrated estimate of global mean sea level change from Topex/Poseidon is too low by approximately 1 mm/yr. We will discuss the challenges of using long-term time series and problems relating to using the global GPS network as a calibration tool.

Bar-Sever, Y. E.↗