Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “plug”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 865 records · Page 48

A Stochastic Multi-Criteria Decision-Making Algorithm for Dynamic Load Prioritization in Grid-Interactive Efficient Buildings

Increasing deployment of advanced sensing, controls, and communication infrastructure enables buildings to provide services to the power grid, leading to the concept of grid-interactive efficient buildings. Since occupant activities and preferences primarily drive the availability and operational flexibility of building devices, there is a critical need to develop occupant-centric approaches that prioritize devices for providing grid services, while maintaining the desired end-use quality of service. In this paper, we present a decision-making framework that facilitates a building owner/operator to effectively prioritize loads for curtailment service under uncertainties, while minimizing any adverse impact on the occupants. The proposed framework uses a stochastic (Markov) model to represent the probabilistic behavior of device usage from power consumption data, and a load prioritization algorithm that dynamically ranks building loads using a stochastic multi-criteria decision-making algorithm. The proposed load prioritization framework is illustrated via numerical simulations in a residential building use-case, including plug-loads, air-conditioners, and plug-in electric vehicle chargers, in the context of load curtailment as a grid service. Suitable metrics are proposed to evaluate the closed-loop performance of the proposed prioritization algorithm under various scenarios and design choices. Scalability of the proposed algorithm is established via computational analysis, while time-series plots are used for intuitive explanation of the ranking choices.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Simplified Numerical Approach to Characterize the Thermal Response of a Moving Bed Solar Reactor

Abstract Concentrated solar thermochemical storage in the form of a zero-emission fuel is a promising option to produce long-duration energy storage. Solar fuel is produced using a cavity reactor that captures concentrated solar radiation from a solar field of heliostats. In this paper, heat transfer model of a tubular plug-flow reactor designed and manufactured for a solar fuel production is presented. Experimental data collected from a fixed bed tubular reactor testing are used for model comparison. The system consists of an externally heated tube with counter-current flowing gas and moving solid particles as the heated media. The proposed model simulates the dynamic behavior of temperature profiles of the tube wall, gas, and particles under various gas flowrates and residence times. The heat transfer between gas–wall, solid particle–wall, and gas–solid particle is numerically studied. The model results are compared with the results of experiments done using a 4 kW furnace with a 150 mm heating zone surrounding a horizontal alumina tube (reactor) with 50.8 mm outer diameter and thickness of 3.175 mm. Solid fixed particles of magnesium manganese oxide (MgMn2O4) with the size of 1 mm are packed within the length of 250 mm at the center of the tube length. Simulation results are assessed with respect to fixed bed experimental data for four different gas flowrates, namely, 5, 10, 15, and 20 standard liters per minute of air, and furnace temperatures in the range of 200–1200 °C. The simulation results showed good agreement with maximum steady state error that is less than 6% of those obtained from the experiments for all runs. The proposed model can be implemented as a low-order physical model for the control of temperature inside plug-flow reactors for thermochemical energy storage applications.

Engineering↗

Evaluation of Spray and Combustion Models for Simulating Dilute Combustion in a Direct-Injection Spark-Ignition Engine

Dilute combustion in spark-ignition engines has the potential to improve thermal efficiency by mitigating knock and by reducing throttling and wall heat losses. However, ignition and combustion processes can become unstable for dilute operation due to a lowered laminar flame speed, resulting in excessive cycle-to-cycle variability (CCV) of the combustion process. To compensate for the slower combustion in less reactive mixtures, a modified intake port geometry can be employed to generate a strong tumble flow in the cylinder and elevate turbulence levels around the spark plug, thereby promoting a faster transition to turbulent deflagration. Consequently, optimizing combustion chamber geometry and operating strategy is crucial to maximizing the benefits of using dilute combustion with enhanced in-cylinder turbulence across a wide range of operating conditions. Computational fluid dynamics (CFD) simulations can be utilized for virtual engine optimization tasks, but this would require the models to be truly predictive regarding the impact of changes to the engine design and operational parameters.In this study, multicycle large-eddy simulations (LES) are performed for a direct-injection spark-ignition engine to investigate the model performance in predicting engine combustion characteristics with respect to changes in the intake configuration. A tumble plate that blocks the lower part of the intake port inlet is used to vary the tumble. A set of CFD models that have been recently developed are employed, which takes into account the drag of nonspherical droplets, flash-boiling behavior of liquid sprays, spray-wall interaction, surrogate formulation of a research-grade E10 gasoline, and fast chemical kinetic solvers. Simulation results are compared to experimental engine data in terms of cylinder pressure, apparent heat release rate, mass fraction burned timing, and flame images. It is found that LES employing the state-of-the-art CFD models are capable of properly predicting the spray processes and reproducing the measured mean cylinder pressure for the case with the tumble plate. On the other hand, the LES over-predicts the combustion rate during the early combustion stage and under-estimates the CCV, and these discrepancies become larger when the tumble plate is removed.

computational fluid dynamics simulation↗

Cooled Spray Technology for Particulate Reduction in a Heavy-Duty Engine

Cooled spray (CS) technology passively reduces particulate matter (PM) emissions from diesel engines compared to non-CS-equipped diesel engines. CS inserts are mounted near the injector nozzle and control mixing so that the fuel and air can premix while limiting combustion near fuel-rich zones, thereby reducing the formation of particulate matter. CS components contain no moving parts and could be installed as a retrofit or built into new engines. However, CS technology is early in its development, and further investigations are needed to understand the overall performance implications and practicality of the technology. In this paper, we investigate several important aspects of CS, providing a clearer picture of some challenges and potential benefits of CS. Two alignment techniques are used to characterize measurement ease and bias, namely, an optical alignment and spray-plug impact alignment. While the optical technique facilitates alignment more easily, a bias was measured between the optical and spray-plug techniques, suggesting the optical technique may have insufficient accuracy without additional corrections. We also evaluate the engine performance of a well-aligned and poorly aligned CS insert, compared to the baseline configuration. The poorly aligned insert shows slower combustion than the baseline and mixed overall performance. However, the well-aligned insert shows faster combustion than the baseline and PM emission reduction at most operating conditions, with some conditions showing PM reduction up to 80%. Furthermore, the results of this paper highlight the alignment challenges of CS technology as well as the potential PM reduction benefit of the technology.

33 ADVANCED PROPULSION SYSTEMS↗

Analytic expressions for atomic layer deposition: Coverage, throughput, and materials utilization in cross-flow, particle coating, and spatial atomic layer deposition

In this work, the authors present analytic models for atomic layer deposition (ALD) in three common experimental configurations: cross-flow, particle coating, and spatial ALD. These models, based on the plug-flow and well-mixed approximations, allow us to determine the minimum dose times and materials utilization for all three configurations. A comparison between the three models shows that throughput and precursor utilization can each be expressed by universal equations, in which the particularity of the experimental system is contained in a single parameter related to the residence time of the precursor in the reactor. For the case of cross-flow reactors, the authors show how simple analytic expressions for the reactor saturation profiles agree well with experimental results. Consequently, the analytic model can be used to extract information about the ALD surface chemistry (e.g., the reaction probability) by comparing the analytic and experimental saturation profiles, providing a useful tool for characterizing new and existing ALD processes.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

CT image artifacts from brachytherapy seed implants: A postprocessing 3D adaptive median filter

Purpose: To design a postprocessing 3D adaptive median filter that minimizes streak artifacts and improves soft-tissue contrast in postoperative CT images of brachytherapy seed implantations. Methods: The filter works by identifying voxels that are likely streaks and estimating more reflective voxel intensity by using voxel intensities in adjacent CT slices and applying a median filter over voxels not identified as seeds. Median values are computed over a 5x5x5 mm region of interest (ROI) within the CT volume. An acrylic phantom simulating a clinical seed implant arrangement and containing nonradioactive seeds was created. Low contrast subvolumes of tissuelike material were also embedded in the phantom. Pre- and postprocessed image quality metrics were compared using the standard deviation of ROIs between the seeds, the CT numbers of low contrast ROIs embedded within the phantom, the signal to noise ratio (SNR), and the contrast to noise ratio (CNR) of the low contrast ROIs. The method was demonstrated with a clinical postimplant CT dataset. Results: After the filter was applied, the standard deviation of CT values in streak artifact regions was significantly reduced from 76.5 to 7.2 HU. Within the observable low contrast plugs, the mean of all ROI standard deviations was significantly reduced from 60.5 to 3.9 HU, SNR significantly increased from 2.3 to 22.4, and CNR significantly increased from 0.2 to 4.1 (all P<0.01). The mean CT in the low contrast plugs remained within 5 HU of the original values. Conclusion: An efficient postprocessing filter that does not require access to projection data, which can be applied irrespective of CT scan parameters has been developed, provided the slice thickness and spacing is 3 mm or less.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Clinical evaluation of a commercial orthopedic metal artifact reduction tool for CT simulations in radiation therapy

Purpose: Severe artifacts in kilovoltage-CT simulation images caused by large metallic implants can significantly degrade the conspicuity and apparent CT Hounsfield number of targets and anatomic structures, jeopardize the confidence of anatomical segmentation, and introduce inaccuracies into the radiation therapy treatment planning process. This study evaluated the performance of the first commercial orthopedic metal artifact reduction function (O-MAR) for radiation therapy, and investigated its clinical applications in treatment planning. Methods: Both phantom and clinical data were used for the evaluation. The CIRS electron density phantom with known physical (and electron) density plugs and removable titanium implants was scanned on a Philips Brilliance Big Bore 16-slice CT simulator. The CT Hounsfield numbers of density plugs on both uncorrected and O-MAR corrected images were compared. Treatment planning accuracy was evaluated by comparing simulated dose distributions computed using the true density images, uncorrected images, and O-MAR corrected images. Ten CT image sets of patients with large hip implants were processed with the O-MAR function and evaluated by two radiation oncologists using a five-point score for overall image quality, anatomical conspicuity, and CT Hounsfield number accuracy. By utilizing the same structure contours delineated from the O-MAR corrected images, clinical IMRT treatment plans for five patients were computed on the uncorrected and O-MAR corrected images, respectively, and compared. Results: Results of the phantom study indicated that CT Hounsfield number accuracy and noise were improved on the O-MAR corrected images, especially for images with bilateral metal implants. The {gamma} pass rates of the simulated dose distributions computed on the uncorrected and O-MAR corrected images referenced to those of the true densities were higher than 99.9% (even when using 1% and 3 mm distance-to-agreement criterion), suggesting that dose distributions were clinically identical. In all patient cases, radiation oncologists rated O-MAR corrected images as higher quality. Formerly obscured critical structures were able to be visualized. The overall image quality and the conspicuity in critical organs were significantly improved compared with the uncorrected images: overall quality score (1.35 vs 3.25, P= 0.0022); bladder (2.15 vs 3.7, P= 0.0023); prostate and seminal vesicles/vagina (1.3 vs 3.275, P= 0.0020); rectum (2.8 vs 3.9, P= 0.0021). The noise levels of the selected ROIs were reduced from 93.7 to 38.2 HU. On most cases (8/10), the average CT Hounsfield numbers of the prostate/vagina on the O-MAR corrected images were closer to the referenced value (41.2 HU, an average measured from patients without metal implants) than those on the uncorrected images. High {gamma} pass rates of the five IMRT dose distribution pairs indicated that the dose distributions were not significantly affected by the CT image improvements. Conclusions: Overall, this study indicated that the O-MAR function can remarkably reduce metal artifacts and improve both CT Hounsfield number accuracy and target and critical structure visualization. Although there was no significant impact of the O-MAR algorithm on the calculated dose distributions, we suggest that O-MAR corrected images are more suitable for the entire treatment planning process by offering better anatomical structure visualization, improving radiation oncologists' confidence in target delineation, and by avoiding subjective density overrides of artifact regions on uncorrected images.

61 RADIATION PROTECTION AND DOSIMETRY↗

Poster — Thur Eve — 11: Validation of the orthopedic metallic artifact reduction tool for CT simulations at the Ottawa Hospital Cancer Centre

Metallic implants in patients can produce image artifacts in kilovoltage CT simulation images which can introduce noise and inaccuracies in CT number, affecting anatomical segmentation and dose distributions. The commercial orthopedic metal artifact reduction algorithm (O-MAR) (Philips Healthcare System) was recently made available on CT simulation scanners at our institution. This study validated the clinical use of O-MAR by investigating its effects on CT number and dose distributions. O-MAR corrected and uncorrected images were acquired with a Philips Brilliance Big Bore CT simulator of a cylindrical solid water phantom that contained various plugs (including metal) of known density. CT number accuracy was investigated by determining the mean and standard deviation in regions of interest (ROI) within each plug for uncorrected and O-MAR corrected images and comparing with no-metal image values. Dose distributions were calculated using the Monaco treatment planning system. Seven open fields were equally spaced about the phantom around a ROI near the center of the phantom. These were compared to a “correct” dose distribution calculated by overriding electron densities a no-metal phantom image to produce an image containing metal but no artifacts. An overall improvement in CT number and dose distribution accuracy was achieved by applying the O-MAR correction. Mean CT numbers and standard deviations were found to be generally improved. Exceptions included lung equivalent media, which is consistent with vendor specified contraindications. Dose profiles were found to vary by ±4% between uncorrected or O-MAR corrected images with O-MAR producing doses closer to ground truth.

60 APPLIED LIFE SCIENCES↗

IBEX: An open infrastructure software platform to facilitate collaborative work in radiomics

Purpose: Radiomics, which is the high-throughput extraction and analysis of quantitative image features, has been shown to have considerable potential to quantify the tumor phenotype. However, at present, a lack of software infrastructure has impeded the development of radiomics and its applications. Therefore, the authors developed the imaging biomarker explorer (IBEX), an open infrastructure software platform that flexibly supports common radiomics workflow tasks such as multimodality image data import and review, development of feature extraction algorithms, model validation, and consistent data sharing among multiple institutions. Methods: The IBEX software package was developed using the MATLAB and C/C++ programming languages. The software architecture deploys the modern model-view-controller, unit testing, and function handle programming concepts to isolate each quantitative imaging analysis task, to validate if their relevant data and algorithms are fit for use, and to plug in new modules. On one hand, IBEX is self-contained and ready to use: it has implemented common data importers, common image filters, and common feature extraction algorithms. On the other hand, IBEX provides an integrated development environment on top of MATLAB and C/C++, so users are not limited to its built-in functions. In the IBEX developer studio, users can plug in, debug, and test new algorithms, extending IBEX’s functionality. IBEX also supports quality assurance for data and feature algorithms: image data, regions of interest, and feature algorithm-related data can be reviewed, validated, and/or modified. More importantly, two key elements in collaborative workflows, the consistency of data sharing and the reproducibility of calculation result, are embedded in the IBEX workflow: image data, feature algorithms, and model validation including newly developed ones from different users can be easily and consistently shared so that results can be more easily reproduced between institutions. Results: Researchers with a variety of technical skill levels, including radiation oncologists, physicists, and computer scientists, have found the IBEX software to be intuitive, powerful, and easy to use. IBEX can be run at any computer with the windows operating system and 1GB RAM. The authors fully validated the implementation of all importers, preprocessing algorithms, and feature extraction algorithms. Windows version 1.0 beta of stand-alone IBEX and IBEX’s source code can be downloaded. Conclusions: The authors successfully implemented IBEX, an open infrastructure software platform that streamlines common radiomics workflow tasks. Its transparency, flexibility, and portability can greatly accelerate the pace of radiomics research and pave the way toward successful clinical translation.

60 APPLIED LIFE SCIENCES↗

SU-E-T-371: Evaluating the Convolution Algorithm of a Commercially Available Radiosurgery Irradiator Using a Novel Phantom

Purpose: The purpose of this study was to develop and use a novel phantom to evaluate the accuracy and usefulness of the Leskell Gamma Plan convolution-based dose calculation algorithm compared with the current TMR10 algorithm. Methods: A novel phantom was designed to fit the Leskell Gamma Knife G Frame which could accommodate various materials in the form of one inch diameter, cylindrical plugs. The plugs were split axially to allow EBT2 film placement. Film measurements were made during two experiments. The first utilized plans generated on a homogeneous acrylic phantom setup using the TMR10 algorithm, with various materials inserted into the phantom during film irradiation to assess the effect on delivered dose due to unplanned heterogeneities upstream in the beam path. The second experiment utilized plans made on CT scans of different heterogeneous setups, with one plan using the TMR10 dose calculation algorithm and the second using the convolution-based algorithm. Materials used to introduce heterogeneities included air, LDPE, polystyrene, Delrin, Teflon, and aluminum. Results: The data shows that, as would be expected, having heterogeneities in the beam path does induce dose delivery error when using the TMR10 algorithm, with the largest errors being due to the heterogeneities with electron densities most different from that of water, i.e. air, Teflon, and aluminum. Additionally, the Convolution algorithm did account for the heterogeneous material and provided a more accurate predicted dose, in extreme cases up to a 7–12% improvement over the TMR10 algorithm. The convolution algorithm expected dose was accurate to within 3% in all cases. Conclusion: This study proves that the convolution algorithm is an improvement over the TMR10 algorithm when heterogeneities are present. More work is needed to determine what the heterogeneity size/volume limits are where this improvement exists, and in what clinical and/or research cases this would be relevant.

60 APPLIED LIFE SCIENCES↗

Daily QA of linear accelerators using only EPID and OBI

Purpose: As treatment delivery becomes more complex, there is a pressing need for robust quality assurance (QA) tools to improve efficiency and comprehensiveness while simultaneously maintaining high accuracy and sensitivity. This work aims to present the hardware and software tools developed for comprehensive QA of linear accelerator (LINAC) using only electronic portal imaging devices (EPIDs) and kV flat panel detectors. Methods: A daily QA phantom, which includes two orthogonally positioned phantoms for QA of MV-beams and kV onboard imaging (OBI) is suspended from the gantry accessory holder to test both geometric and dosimetric components of a LINAC and an OBI. The MV component consists of a 0.5 cm water-equivalent plastic sheet incorporating 11 circular steel plugs for transmission measurements through multiple thicknesses and one resolution plug for MV-image quality testing. The kV-phantom consists of a Leeds phantom (TOR-18 FG phantom supplied by Varian) for testing low and high contrast resolutions. In the developed process, the existing LINAC tools were used to automate daily acquisition of MV and kV images and software tools were developed for simultaneous analysis of these images. A method was developed to derive and evaluate traditional QA parameters from these images [output, flatness, symmetry, uniformity, TPR{sub 20/10}, and positional accuracy of the jaws and multileaf collimators (MLCs)]. The EPID-based daily QA tools were validated by performing measurements on a detuned 6 MV beam to test its effectiveness in detecting errors in output, symmetry, energy, and MLC positions. The developed QA process was clinically commissioned, implemented, and evaluated on a Varian TrueBeam LINAC (Varian Medical System, Palo Alto, CA) over a period of three months. Results: Machine output constancy measured with an EPID (as compared against a calibrated ion-chamber) is shown to be within ±0.5%. Beam symmetry and flatness deviations measured using an EPID and a 2D ion-chamber array agree within ±0.5% and ±1.2% for crossline and inline profiles, respectively. MLC position errors of 0.5 mm can be detected using a picket fence test. The field size and phantom positioning accuracy can be determined within 0.5 mm. The entire daily QA process takes ∼15 min to perform tests for 5 photon beams, MLC tests, and imaging checks. Conclusions: The exclusive use of EPID-based QA tools, including a QA phantom and simultaneous analysis software tools, has been demonstrated as a viable, efficient, and comprehensive process for daily evaluation of LINAC performance.

60 APPLIED LIFE SCIENCES↗

Master-Slave Control Scheme in Electric Vehicle Smart Charging Infrastructure

WINSmartEV is a software based plug-in electric vehicle (PEV) monitoring, control, and management system. It not only incorporates intelligence at every level so that charge scheduling can avoid grid bottlenecks, but it also multiplies the number of PEVs that can be plugged into a single circuit. This paper proposes, designs, and executes many upgrades to WINSmartEV. These upgrades include new hardware that makes the level 1 and level 2 chargers faster, more robust, and more scalable. It includes algorithms that provide a more optimal charge scheduling for the level 2 (EVSE) and an enhanced vehicle monitoring/identification module (VMM) system that can automatically identify PEVs and authorize charging.

42 ENGINEERING↗

SimApp 1.8.x

System for converting DESIRE (Direct Executing Simulation in Real Time) simulation models to executable code models (C# / C++). These converted models are used as the basis for 2 products, one of which is the focus of this review: an engineering design interface for Fissile Solution Systems. ModelConverter.exe (C#) converts DESIRE model inputs to a C++ plug-in subclass. SimApp.exe (C# / C++) has a C++ dll that is a numerical integration engine that the Converted models plug into. The engineering design interface is a C# GUI that calls on the C++ dll to execute a particular converted model. The GUI allows the user to specify the length of a simulation, run the simulation, view data plots and data tables. Stability plots may also be produced and manipulated. The engineering design interface will be released as source code and executable; the model converter source is also intended for release.

Determan, JohnC.↗

Building Energy Management Open Source Software

This is the repository for Building Energy Management Open Source Software (BEMOSS), which is an open source operating system that is engineered to improve sensing and control of equipment in small- and medium-sized commercial buildings. BEMOSS offers the following key features: (1) Open source, open architecture – BEMOSS is an open source operating system that is built upon VOLTTRON – a distributed agent platform developed by Pacific Northwest National Laboratory (PNNL). BEMOSS was designed to make it easy for hardware manufacturers to seamlessly interface their devices with BEMOSS. Software developers can also contribute to adding additional BEMOSS functionalities and applications. (2) Plug & play – BEMOSS was designed to automatically discover supported load controllers (including smart thermostats, VAV/RTUs, lighting load controllers and plug load controllers) in commercial buildings. (3) Interoperability – BEMOSS was designed to work with load control devices form different manufacturers that operate on different communication technologies and data exchange protocols. (4) Cost effectiveness – Implementation of BEMOSS deemed to be cost-effective as it was built upon a robust open source platform that can operate on a low-cost single-board computer, such as Odroid. This feature could contribute to its rapid deployment in small- or medium-sized commercial buildings. (5) Scalability and ease of deployment – With its multi-node architecture, BEMOSS provides a distributed architecture where load controllers in a multi-floor and high occupancy building could be monitored and controlled by multiple single-board computers hosting BEMOSS. This makes it possible for a building engineer to deploy BEMOSS in one zone of a building, be comfortable with its operation, and later on expand the deployment to the entire building to make it more energy efficient. (6) Ability to provide local and remote monitoring – BEMOSS provides both local and remote monitoring ability with role-based access control. (7) Security – In addition to built-in security features provided by VOLTTRON, BEMOSS provides enhanced security features, including BEMOSS discovery approval process, encrypted core-to-node communication, thermostat anti-tampering feature and many more. (8) Support from the Advisory Committee – BEMOSS was developed in consultation with an advisory committee from the beginning of the project. BEMOSS advisory committee comprises representatives from 22 organizations from government and industry.

Source record↗

Data Transfer Software-SAS MetaData Server & Phoenix Integration Model Center

This software is a plug-in that interfaces between the Phoenix Integration's Model Center and the Base SAS 9.2 applications. The end use of the plug-in is to link input and output data that resides in SAS tables or MS SQL to and from "legacy" software programs without recoding. The potential end users are users who need to run legacy code and want data stored in a SQL database.

Alessi, R.Sam↗

MarmotViz

MarmotViz is an illustrative visualization plug-in for ParaView. It enables users to identify and track time-varying features in simulation datasets. It permits the application of illustrative visualization effects to these features including: selective visualization, feature coloring, boundary smoothing, haloing, silhouette outlining, speedlines, and strobe silhouettes. These techniques serve to assist in exploration and interpretation of simulation data and can be used to generate enhanced renderings for presentation. The MarmotViz plug-in is developed as a flexible framework, and can be easily extended to incorporate new region-of-interest (ROI) identification algorithms, feature matching and tracking algorithms, and illustrative visualization effects.

Rattner, Alexander↗

Data for Propagation Method and Planting Density Influence Canopy Developmental Transition and Biomass Productivity in Miscanthus × giganteus

Understanding how establishment practices influence the mechanisms underlying Miscanthus × giganteus (miscanthus) productivity and canopy development is critical for optimizing management. Data was collected during the juvenile (2011–2013) and mature (2024) phases of a long-term field experiment established in Urbana, Illinois, to evaluate the effects of propagation method (plug propagation [PP] and rhizome propagation [RP]), planting density (1.0, 0.75, and 0.25 plants m⁻²), and nitrogen application (0 and 67 kg N ha⁻¹) on end-of-season biomass yield, tiller mass, tiller density, and tiller height. Linear regression models identified the dominant predictors of yield across stand ages and management regimes. Planting density, nitrogen (N) application, and propagation method significantly influenced early yield and canopy development. During the juvenile phase, biomass yield was driven by tiller density due to canopy expansion; in the mature phase, yield became driven by tiller mass. The PP plots produced higher tiller density than the RP plots, resulting in faster canopy closure and higher juvenile-phase yields. Rhizome-propagated (RP) plots produced lower tiller density, but individual tillers were 3.3–6.4 g tiller−1 heavier than PP tillers. After the canopy reached equilibrium, the PP and RP yields were similar because greater RP tiller mass compensated for its lower tiller density. Higher planting density resulted in greater yield and tiller density during the second year (2012), but this effect was absent from the third year (2013) onward. In the juvenile phase, N fertilization enhanced yield by 1.6–3.4 Mg ha−1. Initiating fertilization in 2013 on unfertilized plots produced biomass similar to that in fertilized plots, suggesting yield recovery in the mature phase. These findings revealed that establishment strategies, including propagation method and planting density, influence juvenile miscanthus canopy development and productivity, transitioning from tiller-density- to mass-dominated yields, but not mature phase productivity.

Miscanthus↗

Stacked-mosaic amplifier and diode delivery concept for kJ-class inertial fusion energy laser driver

We report on a laser amplifier architecture designed as a modular element for scaling to multi-megajoule laser facilities intended for inertial fusion energy (IFE) power plants. This kilojoule-class module features a stacked mosaic of gain media integrated with a diode delivery system for efficient optical pumping of the mosaic-structured gain medium, enabling high-repetition-rate operation at high wall plug efficiencies, necessary for an IFE driver. Details of a diode delivery system capable of pumping the mosaic architecture are presented. Comprehensive numerical modeling demonstrates that the stacked-mosaic approach reduces transverse gain by five orders of magnitude compared to a conventional full-aperture Yb:YAG based amplifier, substantially suppressing transverse amplified spontaneous emission (TASE) and enabling enhanced longitudinal energy extraction. Detailed analysis of thermal management and wavefront distortion in a 4 × 4 mosaic array indicates that temperature gradients and thermally induced aberrations are effectively controlled using gas cooling and commercially available phase-plate and deformable mirror technologies. We further discuss the applicability of a stacked-mosaic architecture to direct-drive IFE schemes, where broad spectral bandwidth is critical, and its compatibility with frequency conversion modules for up-conversion to blue wavelengths. Finally, an example point design for a 10 kJ, 10 Hz Yb:YAG module operating at 175 K with wall-plug efficiency exceeding 10 % is presented, underscoring the feasibility of this approach for next-generation high-energy lasers for IFE drivers. The results establish the stacked-mosaic amplifier as a scalable, robust platform not only for IFE but also for a broad range of advanced scientific and industrial laser applications.

Lasers↗