Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “phase transfer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 865 records · Page 48

Microwave radiances from precipitating clouds containing aspherical ice, combined phase, and liquid hydrometeors

A numerical algorithm based on Eddington's second approximation to the equation of radiative transfer has been developed in order to compute the radiances with horizontal and vertical polarization that emerge from precipitating clouds. This algorithm yields a rapid solution to problems pertaining to clouds with vertically inhomogeneous structure. Precipitating clouds containing liquid, mixtures of phases, and ice hydrometeors are modelled. It is shown that the lower-frequency radiances are sensitive to liquid precipitation at low altitudes while the higher-frequency radiances are more sensitive to the ice hydrometeors at the cloud tops. The extinction coefficients of aspherical hydrometeors are presented as a function of rainfall rates. The fact that vertically polarized radiances are warmer than horizontally polarized ones at high rainfall rates, with the difference diminishing at lower frequencies, is due to aspherical ice hydrometeors in the upper regions of precipitating clouds.

Wu, R.↗

Performance analysis and simulation of the SPS reference phase control system

The solar power satellite (SPS) concept envisions several hundred thousand synchronized microwave power amplifiers operating in parallel to produce an aggregate power output of 5-10 GW. This power is to be transferred to earth with the aid of a microwave/millimeter-wave beaming system operating in a synchronous orbit. The reference phase control system is considered along with aspects of pilot signal parameter selection. A power transponder analysis is conducted and an SPS performance evaluation is performed. Attention is given to system jitters and imperfections, the definition of power transfer efficiency, and the effects of system imperfections on SPS efficiency. It is found that the power transfer efficiency is relatively insensitive to the amplitude jitters. However, the effects of location jitters can produce a severe degradation of efficiency.

Chie, C. M.↗

Phase and Pupil Amplitude Recovery for JWST Space-Optics Control

This slide presentation reviews the phase and pupil amplitude recovery for the James Webb Space Telescope (JWST) Near Infrared Camera (NIRCam). It includes views of the Integrated Science Instrument Module (ISIM), the NIRCam, examples of Phase Retrieval Data, Ghost Irradiance, Pupil Amplitude Estimation, Amplitude Retrieval, Initial Plate Scale Estimation using the Modulation Transfer Function (MTF), Pupil Amplitude Estimation vs lambda, Pupil Amplitude Estimation vs. number of Images, Pupil Amplitude Estimation vs Rotation (clocking), and Typical Phase Retrieval Results Also included is information about the phase retrieval approach, Non-Linear Optimization (NLO) Optimized Diversity Functions, and Least Square Error vs. Starting Pupil Amplitude.

Dean, B. H.↗

Design of a Thrust Vector Servoelastic Filter for SLS Block 2 Booster Thrust Vector Control System

This paper presents a method to improve the thrust vector servoelastic (TVSE) response of a launch vehicle. TVSE is the coupling between the Thrust Vector Control (TVC) system nozzle dynamics and the vehicle flexible modes. A poorly phased TVC response, i.e. in phase with the structural velocity, can lead to instability of the flexible modes due to the energy injection from the thrust. For large boosters with heavy nozzles, TVSE is more likely to cause instability. This instability is part of the plant dynamics and may not be readily detected by the flight control system. In this paper, TVSE is treated as a disturbance rejection problem with the inertial force of the flexible motion viewed as an external disturbance to the TVC actuator control system. By effectively rejecting this disturbance, the engine can be decoupled from the flexible dynamics thus improving TVSE stability. The actuator disturbance transfer function is modified by inserting a filter into the servo-loop control system. The filter aims to reduce the magnitude and introduce phase lead of the disturbance transfer function over the TVSE sensitive frequency range while maintaining adequate stability margins of the actuator control system. A prefilter is also designed to improve command tracking performance. The filter and prefilter resulting from this method are usually of low order and can be included to an existing actuator controller if the controller is programmable. This method was demonstrated for a hydraulic Simplex actuator model. Its applications to the Space Launch System (SLS) Block 1 and Block 2 TVC actuator are also described. The Block 2 actuator controller was modified based on the results of this method. The tradeoff between TVSE stability and the servo-loop stability can be balanced by adjusting the amount of phase lead introduced by the TVSE filter. This method provides a useful way to solve the TVSE instability issue without costly and time-consuming hardware solutions. This method is based on the basic control principles of loop shaping and disturbance rejection and has been proven to be effective under proper circumstances.

Thrust vector control↗

Heat Transfer and Interfacial Flow Physics of Microgravity Flow Boiling in Single-Side-Heated Rectangular Channel with Subcooled Inlet Conditions – Experiments Onboard the International Space Station

This study is the culmination of a long-term collaborative effort between researchers from the Purdue University Boiling and Two-Phase Flow Laboratory (PU-BTPFL) and the NASA Glenn Research Center to investigate gravitational effects on flow boiling and flow condensation. The science and design concepts for this large-scale effort were initiated in 2011 and included several studies detailing various aspects of two-phase fluid physics in both Earth gravity and microgravity, culminating in construction of the large-scale experimental facility named “Flow Boiling and Condensation Experiment (FBCE)”. The experiment was launched to the International Space Station (ISS) in August 2021. Following the successful installation of FBCE, equipped with the Flow Boiling Module (FBM), onboard the ISS and completion of several safety checks, flow boiling experiments were performed for five months from February 2022 until July 2022. This resulted in a large flow boiling database covering broad ranges of operating parameters and heating configurations spanning several research objectives. This study investigates microgravity flow boiling of n-perfluorohexane with subcooled inlet in a single-side-heated rectangular channel of dimensions 114.6-mm heated length, 2.5-mm heated width, and 5.0-mm height. Key operating parameters investigated are mass velocity (199.90 – 3200.13 kg/m 2 s), inlet subcooling (0.10 – 45.76°C), and inlet pressure (113.30 – 164.29 kPa). Images and image sequences acquired via high-speed-video are presented to elucidate the interfacial flow physics. To analyze and explain the effects of various parameters in microgravity, heat transfer results are presented as flow boiling curves, streamwise profiles of wall temperature and heat transfer coefficient, and parametric trends of local and averaged heat transfer coefficient. Mass velocity and inlet subcooling significantly influenced most of the aforementioned aspects of flow boiling, whereas effects of inlet pressure were comparatively insignificant. Although the data and observed flow physics might be different, the parametric effects and trends in microgravity are similar to vertical upflow in Earth gravity. Some cases, especially low mass velocities, high heat fluxes, and large degrees of inlet subcooling, experienced temporally anomalous flow behaviors caused by two-phase flow instabilities manifesting as flow reversals and resulted in deviations in overall trends. Severe thermodynamic non-equilibrium is observed throughout the channel. Overall, FBCE’s ISS experiments were successful for subcooled inlet with single-sided heating of rectangular channel, and the collected data well established the various effects on flow boiling physics in highly controlled long-term microgravity conditions.

flow boiling↗

Space station experiment definition: Long term cryogenic fluid storage

A preliminary design of an experiment to demonstrate and evaluate long-term cryogenic fluid storage and transfer technologies has been performed. This Long-Term Cryogenic Fluid Storage (LTCFS) experiment is a Technology Development Mission (TDM) experiment proposed by the NASA Lewis Research Center to be deployed on the Initial Operational Capability (IOC) space station. Technologies required by future orbital cryogenic systems such as Orbital Transfer Vehicles (OTV's) were defined, and critical technologies requiring demonstration were chosen to be included in the experiment. A three-phase test program was defined to test the following types of technologies: (1) Passive Thermal Technologies; (2) Fluid Transfer Technologies; and (3) Active Refrigeration Technologies. The development status of advanced technologies required for the LTCFS experiment is summarized, including current, past and future programs.

Riemer, David H.↗

Zero Boil-Off Tank (ZBOT) Experiment

The Zero-Boil-Off Tank (ZBOT) experiment has been developed as a small scale ISS experiment aimed at delineating important fluid flow, heat and mass transport, and phase change phenomena that affect cryogenic storage tank pressurization and pressure control in microgravity. The experiments use a simulant transparent low boiling point fluid (PnP) in a sealed transparent Dewar to study and quantify: (a) fluid flow and thermal stratification during pressurization; (b) mixing, thermal destratification, depressurization, and jet-ullage penetration during pressure control by jet mixing. The experiment will provide valuable microgravity empirical two-phase data associated with the above-mentioned physical phenomena through highly accurate local wall and fluid temperature and pressure measurements, full-field phase-distribution and flow visualization. Moreover, the experiments are performed under tightly controlled and definable heat transfer boundary conditions to provide reliable high-fidelity data and precise input as required for validation verification of state-of-the-art two-phase CFD models developed as part of this research and by other groups in the international scientific and cryogenic fluid management communities.

ISS↗

Effective thermal property improves phase change paint data

The phase-change coating technique presents itself as a valuable tool in determining the heat transfer rate over the surface of small complex wind tunnel models. A numerical technique is described which shows that an effective thermophysical property - the square root of the product of thermal conductivity, density, and specific heat - may significantly improve the accuracy of the phase-change coating technique with allowance for model inhomogeneity and temperature dependency in a transient environment. Results of the measured steady-state variation of the effective thermophysical property with temperature and the effect of surface heating rate on the effective thermophysical property are plotted for a representative homogeneous model material and for an extreme nonhomogeneous model material. The use of an effective thermophysical property to reduce phase-change paint data is recommended. The analysis also confirms that the apparatus described by Corwin and Kramer (1975) can be used to measure directly this effective thermophysical property for use in wind tunnel model heat-transfer measurements.

Drummond, J. P.↗

A sub-nanosecond CCD

A 32-cell silicon n-channel PCCD was fabricated and tested for charge transfer efficiency versus transfer time. A charge transfer time of 550 picoseconds with a 0.9998 transfer efficiency was obtained when operated in the uni-phase mode. These conditions correspond to an operating rate of 900 MHz when operated as an analog data or digital device.

Chan, Y. T.↗

Interpretation of spatial and temporal variations of hydrogen quadrupole absorptions in the Jovian atmosphere observed during the 1972 apparition

Results are reported for a systematic investigation of temporal and spatial variations of hydrogen quadrupole lines formed in the Jovian atmosphere, which was performed by measuring the strengths of the S(1) lines of H2 (3,0) and (4,0) quadrupole bands at several points on the Jovian disk during the 1972 apparition. The observations support the hypothesis that the strength of the (3,0) S(1) line varies significantly with time, suggest the possibility of short-term temporal variation in the strength of the (4,0) line, and indicate that the H2 line strengths vary remarkably little from limb to limb in the equatorial region. A Galatry line-shape profile is calculated, and a radiative-transfer analysis is carried out using the Henyey-Greenstein phase function for single particle scattering. It is shown that the observations are consistent with a multilayer atmospheric model having an optically thin upper cloud deck separated by a stratum of nonscattering gas from an optically thick lower cloud.

Hunt, G. E.↗

Conceptual design for spacelab pool boiling experiment

A pool boiling heat transfer experiment to be incorporated with a larger two-phase flow experiment on Spacelab was designed to confirm (or alter) the results of earth-normal gravity experiments which indicate that the hydrodynamic peak and minimum pool boiling heat fluxes vanish at very low gravity. Twelve small sealed test cells containing water, methanol or Freon 113 and cylindrical heaters of various sizes are to be built. Each cell will be subjected to one or more 45 sec tests in which the surface heat flux on the heaters is increased linearly until the surface temperature reaches a limiting value of 500 C. The entire boiling process will be photographed in slow-motion. Boiling curves will be constructed from thermocouple and electric input data, for comparison with the motion picture records. The conduct of the experiment will require no more than a few hours of operator time.

Lienhard, J. H.↗

Microwave emission from polar firn

The microwave emission from a half-space medium, characterized by coordinate dependent scattering and absorbing centers, was calculated by numerically solving the radiative transfer equation by the method of invariant imbedding. Rayleigh scattering phase functions and scattering induced polarization of the radiation were included in the calculation. Using the scattering and extinction data of polar firn the brightness temperature was calculated for the 1.55 cm wavelength. This study was the first quantitative comparison of the results of numerical calculation using the actual measured information of crystal size with the observed data.

Chang, A. T. C.↗

Analytical Modeling of Operating Characteristics of Premixing-prevaporizing Fuel-air Mixing Passages

A model for predicting the distribution of liquid fuel droplets and fuel vapor in premixing-prevaporizing fuel-air mixing passages of the direct injection type is described. This model consists of three computer programs: a calculation of the two dimensional or axisymmetric air flow field neglecting the effects of fuel; a calculation of the three dimensional fuel droplet trajectories and evaporation rates in a known, moving air flow; and a calculation of fuel vapor diffusing into a moving three dimensional air flow with source terms dependent on the droplet evaporation rates. The air flow calculation can treat compressible swirling flows in arbitrary ducts with arbitrary distributions of temperature and velocity as initial conditions. The fuel droplets are treated as initial conditions. The fuel droplets are treated as individual particle classes each satisfying Newton's law, a heat transfer, and a mass transfer equation. The vapor diffusion calculation treats three dimensional, gas phase, turbulent diffusion processes with the turbulence level determined by the air flow calculations and the source terms determined by the droplet evaporation rates.

Anderson, O. L.↗

The Space Shuttle focused-technology program - Lessons learned

The results of a focused technology program (FTP), its management structure, the development of the Space Shuttle, and lessons applicable to future space programs such as a space station are discussed. A committee was formed by NASA in 1969 to define the technologies necessary for a reusable spacecraft. Basic and applied research assessments were featured at the beginning of the process. Working groups were established to cover all necessary areas, e.g., Operations, Structures and Materials, Aerothermodynamics, etc., and tasks were distributed to appropriate NASA centers. Funding was drawn from existing budgets. The FTP proceeded successfully because of an understanding of the respective roles of industry and government, the willingness of industry to invest early in a new technology, and the unclassified status of information generated by the program. The in-house design and technology transfer methods that brought the project to a technology demonstration phase are explored, noting the necessity for users to take part in the development within their field.

Fitzgerald, P. E., Jr.↗

Heating measurements on Space Shuttle Orbiter models with differentially deflected elevons

The phase-change paint technique was used to make heat-transfer measurements on five Space Shuttle Orbiter models with differentially-deflected elevons. The outboard elevons were deflected windward through an angle delta when the inboard elevons were deflected through an angle - 2delta, where delta = 0, 5, 10, 15, and 20 deg. The models were tested in air at Mach 6 and Mach 10 with two different flow conditions at each Mach number. Each test was run at three angles of attack; 20, 28, and 35 deg. This study was restricted to the windward side of the wing/elevons area. Multiple chord-wise streaks of high heating often occurred on the wings and sometimes extended to localized spots of high heating on the windward-deflected elevons. The extent of heating was a function of angle of attack and test conditions, but in general differential deflection of the elevons affected the wing heat-transfer coefficient on the order of 40 percent or less whereas the windward elevon heat-transfer coefficient was a function of the deflection angle and could be many times the value determined for the undeflected elevon.

Wells, W. L.↗

Algorithm for Fluid Networks

Algorithm performs either transient integration or steady-state relaxation of network that represents internal fluid system. Valid for both single and two-phase flow of any fluid and includes both heat-transfer and work terms. General enough to simulate almost any flow system to almost any degree of detail desired. Encoded into computer program FLUINT, will work in conjunction with SINDA-85 program to enable analysis of pipelines; heating, ventilating, and cooling systems; and almost any other system that involves both fluid flow and heat transfer. Other possible extensions includes effects of flexibilities of containers, high-velocity flow, gravitation, acceleration, and opening and closing valves.

Cullimore, Brent A.↗

High-Performance Ambient-Temperature Heat Pipe

Heat pipe with two channels designed for regulation of temperature in enclosed spaces. Made of aluminum, heat-transfer material is ammonia. Contains two channels: one for vapor phase and one for liquid phase of ammonia. Porous wick of sintered aluminum powder lines vapor channel and fills slot between two channels. Design confers several advantages.

Keddy, Michael D.↗