Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “optical Interferometer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 865 records · Page 48

The Filled Arm Fizeau Telescope (FFT)

Attention is given to the design of a Mills Cross imaging interferometer in which the arms are fully filled with mirror segments of a Ritchey-Chretien primary and which has sensitivity to 27th magnitude per pixel and resolution a factor of 10 greater than Hubble. The optical design, structural configuration, thermal disturbances, and vibration, material, control, and metrology issues, as well as scientific capabilities are discussed, and technology needs are identified. The technologies under consideration are similar to those required for the development of the other imaging interferometers that have been proposed over the past decade. A comparison of the imaging capabilities of a 30-m diameter FFT, an 8-m telescope with a collecting area equal to that of the FFT, and the HST is presented.

Synnott, S. P.↗

Method and Apparatus of Multiplexing and Acquiring Data from Multiple Optical Fibers Using a Single Data Channel of an Optical Frequency-Domain Reflectometry (OFDR) System

A method and system for multiplexing a network of parallel fiber Bragg grating (FBG) sensor-fibers to a single acquisition channel of a closed Michelson interferometer system via a fiber splitter by distinguishing each branch of fiber sensors in the spatial domain. On each branch of the splitter, the fibers have a specific pre-determined length, effectively separating each branch of fiber sensors spatially. In the spatial domain the fiber branches are seen as part of one acquisition channel on the interrogation system. However, the FBG-reference arm beat frequency information for each fiber is retained. Since the beat frequency is generated between the reference arm, the effective fiber length of each successive branch includes the entire length of the preceding branch. The multiple branches are seen as one fiber having three segments where the segments can be resolved. This greatly simplifies optical, electronic and computational complexity, and is especially suited for use in multiplexed or branched OFS networks for SHM of large and/or distributed structures which need a lot of measurement points.

Parker, Jr., Allen R↗

Prospect of space-based interferometry at EUV and soft X-ray wavelengths

We review the current capabilities of high-resolution, spectroscopic, space-borne instrumentation available for both solar and stellar observations in the EUV and soft X-ray wavelength regimes, and describe the basic design of a compact, all-reflection interferometer based on the spatial heterodyne technique; this is capable of producing a resolving power (lambda/Delta-lambda) of about 20,000 in the 100-200 A region using presently available multilayer optical components. Such an instrument can be readily constructed with existing technology. Due to its small size and lack of moving parts, it is ideally suited to spaceborne applications. Based on best estimates of the efficiency of this instrument at soft X-ray wavelengths, we review the possible use of this high-resolution interferometer in obtaining high-resolution full-disk spectroscopy of the sun. We also discuss its possible use for observations of diffuse sources such as the EUV interstellar background radiation.

Welsh, Barry Y.↗

Interferometric bunch length measurements of 3 MeV picocoulomb electron beams

We report picosecond bunch length measurements using an interferometric method for a 3 MeV electron beam having bunch charge ranging from 1 to 14 pC. The method senses the single-cycle sub-terahertz (THz) pulse emitted by each electron bunch as coherent transition radiation which, in turn, is analyzed using a Michelson-type interferometer, forming an interferogram that is then processed to yield the nominal electron bunch length. This sub-THz coherent radiation intensity was measured using a quasi-optical detector (QOD) operated at room temperature. This experiment was quite challenging since the divergence angle of the sub-THz pulse emitted by the low-energy electron bunch exceeds ±10°, and its pulse energy at the entrance to the detector was as low as 100 pJ. When compared to a conventional helium-cooled silicon composite bolometer designed for frequencies above 0.5 THz, the QOD provided much better signal-to-noise ratio in the ~80 GHz frequency range, which was critical for the successful measurement of the bunch length.

36 MATERIALS SCIENCE↗

First height comparison of noctilucent clouds and simultaneous PMSE

On the night of August 9-10, 1991, two rocket payloads were launched into simultaneously occurring noctilucent clouds (NLC) and polar mesospheric summer echoes (PMSE) above Esrange, a third rocket payload was launched into a NLC where a PMSE was detected 5 minutes later above Esrange, in Sweden as part of the NLC-91 campaign. An aim of this experiment was to compare the vertical structures and locations of the NLC and PMSE events. To this end, in-situ optical photometers and particle impact sensors were used to measure the altitude and vertical structure of the NLC layer, while the Cornell University portable radar interferometer (CUPRI) was used to probe the PMSE. Although this comparison is complicated by the horizontal separations between the in-situ measurements and the radar volume, and low electron densities which reduced the overall radar reflectivity, we conclude that the PMSE layer in the CUPRI radar volume remained above the NLC layer detected by the in-situ instruments by 300 to 2000 m throughout the experiment. We interpret this result as supporting the view that PMSE are more likely to result from the presence of aerosols smaller than the ones optically detectable as NLCs.

Waelchli, Urs↗

Nonperturbative Zou-Wang-Mandel effect

The Zou-Wang-Mandel (ZWM) effect is a remarkable consequence of photon indistinguishability and continuous-variable entanglement in which an optical phase shift is imprinted on photonic modes associated with optical paths that that do not pass through the phase shift source. By bringing the canonical formalism of continuous-variable Gaussian states to bear on the mode-structure of the ZWM experiment, we show that the physical consequence of implementing optical path identity is a renormalization of quadrature squeezing which governs the entanglement of four effective optical modes. Nonperturbative expressions for the ZWM interference patterns and normalized first-order coherence function are derived. Generalizations to $\mathscr{H}$-graph states with more than four modes directly follow from the general method used to analyze the minimal example. Here, we show that a ZWM interferometer with a laser-seeded signal mode, which estimates an idler phase shift by detecting photons that did not propagate through the phase shift, exhibits an optimal sensitivity comparable to that of a laser-seeded SU(1,1) interferometer if path identity is implemented with high fidelity.

74 ATOMIC AND MOLECULAR PHYSICS↗

An optically pumped submillimeter wavelength regenerative amplifier

An optically pumped regenerative submillimeter laser amplifier is described. The amplifier uses a waveguide cavity resonator, and a Fabry-Perot interferometer composed of two dielectric-coated mirrors serves as input and output port for the submillimeter signal. Use of two mirrors enabled obtaining variations of up to 6:1 in transmission by varying the mirror spacing. When the 373-micron transition in CH3CN is excited in the oscillator by the CO2 laser pump beam, the received signal with amplification is about nine times the unamplified signal.

Galantowicz, T. A.↗

Infrared Fabry-Perot and heterodyne spectrometers

The status of infrared instrumentation for astronomical investigations at U.C. Berkeley is described with emphasis on the techniques of high spectral and spatial resolution. Present instrumentation includes three Fabry-Perot spectrometers for the 10, 20, and 100 micron wavelength regions, a submillimeter receiver using an optically pumped laser, a 10 micron heterodyne spectrometer for studies of planetary atmospheres, and a 2-element 10 micron stellar interferometer for measuring the angular diameters of infrared stars.

Betz, A.↗

The Mark III stellar interferometer

The Mark III interferometer is an operational long baseline stellar interferometer on Mt. Wilson with four-possible baseline configurations from 9m NE-SW to 20m N-S. The interferometer was designed to be a highly automated astronomical instrument to measure stellar positions and diameters to a magnitude limit of seven. Initial fringe observations were made in September 1986 with a 12-m N-S baseline. In the following months, semi-automated astrometric and stellar diameter measurements were also made. This paper describes the hardware and software components of the instrument and its operational characteristics. The interferometer has several novel features. One is the use of optimal estimation and control algorithms (e.g. Kalman filters) in the control loops. Another is the ability to operate both as a closed-loop phased interferometer and eventually as an open-loop or absolute coherent interferometer. High thermal stability and mechanical accuracy should permit the instrument to point blind at an astronomical object and maintain optical path equality to within the limits set by the atmosphere. In this absolute interferometric mode of operation, it should be possible to observe faint astronomical objects that are too dim for phase tracking. In theory, measurements of amplitude, group delay, and closure phase will be possible to 14 mag.

Shao, M.↗

Accelerating the Deployment of Space-Based Quantum Sensors

Quantum sensors rely on quantum mechanical properties, such as wave-particle duality, atomic energy levels, or entanglement, to measure physical, optical, or electromagnetic information from a target. Examples include Rydberg sensors, nitrogen-vacancy magnetometers, HOM (Hong-Ou-Mandel) interferometers, and SQUIDs (Superconducting Quantum Interference Devices). In general, as quantum sensors rely on interrogation at the atomic and photonic level rather than on classical mechanical measurements, these technologies promise advantages over their traditional counterparts in sensitivity, accuracy, and SWaP (Size, Weight, and Power). Conceptually, the use of quantum sensors unlocks the new phenomenology of sensor entanglement. While an ultra-low TRL (Technology Readiness Level) prospect for most sensor types, multi-sensor entanglement is a high risk, high reward strategy with a potential for exquisite sensitivity and SWaP improvements entirely inaccessible to classical sensors.

Grace Caroline Wusk↗

Interferometric rotation sensor

An interferometric rotation sensor and control system is provided which includes a compound prism interferometer and an associated direction control system. Light entering the interferometer is split into two paths with the light in the respective paths being reflected an unequal number of times, and then being recombined at an exit aperture in phase differing relationships. Incoming light is deviated from the optical axis of the device by an angle, alpha. The angle causes a similar displacement of the two component images at the exit aperture which results in a fringe pattern. Fringe numbers are directly related to angle alpha. Various control systems of the interferometer are given.

Walsh, T. M.↗

Theoferometer for the Construction of Precision Optomechanical Assemblies

The increasing difficulty of metrology requirements on projects involving optics and the alignment of instrumentation on spacecraft has reached a turning point. Requirements as low as 0.1 arcseconds for the static, rotational alignment of components within a coordinate system cannot be met with a theodolite, the alignment tool currently in use. A "theoferometer" is an interferometer mounted on a rotation stage with degrees of freedom in azimuth and elevation for metrology and alignment applications. The success of a prototype theoferometer in approaching these metrology requirements led to a redesign stressing mechanical, optical, and software changes to increase the sensitivity and portability of the unit. This paper covers the improvements made to the first prototype theoferometer, characteristic testing, and demonstration of the redesigned theoferometer s capabilities as a "theodolite replacement" and low-uncertainty metrology tool.

Korzun, Ashley M.↗

The Least-Squares Calibration on the Micro-Arcsecond Metrology Test Bed

The Space Interferometry Mission (S1M) will measure optical path differences (OPDs) with an accuracy of tens of picometers, requiring precise calibration of the instrument. In this article, we present a calibration approach based on fitting star light interference fringes in the interferometer using a least-squares algorithm. The algorithm is first analyzed for the case of a monochromatic light source with a monochromatic fringe model. Using fringe data measured on the Micro-Arcsecond Metrology (MAM) testbed with a laser source, the error in the determination of the wavelength is shown to be less than 10pm. By using a quasi-monochromatic fringe model, the algorithm can be extended to the case of a white light source with a narrow detection bandwidth. In SIM, because of the finite bandwidth of each CCD pixel, the effect of the fringe envelope can not be neglected, especially for the larger optical path difference range favored for the wavelength calibration.

interferometer calibrations↗

Cosmic axions revealed via amplified modulation of the ellipticity of a laser

We propose a new axion dark matter detection strategy that employs optical readout of laser beam ellipticity modulations caused by axion-induced electric fields in a microwave cavity, using electro-optic (EO) crystals, enhanced by externally injected radio-frequency (rf) power. Building upon the variance-based probing method [Phys. Rev. D 107, 103005 (2023).], we extend this concept to the optical domain: A weak probe laser interacts with an EO crystal coupled to the resonant microwave cavity field at cryogenic temperatures, and the axion-induced electric field is revealed through induced ellipticity. The injected rf signal coherently interferes with that of the axion field, amplifying the optical response and significantly improving sensitivity. While our EO-based method employs a Fabry-Pérot resonator, we do not require Michelson interferometers. Our method, hence, enables compact, high-frequency axion searches, across the 0.5–50 GHz range. Operating at cryogenic temperatures not only suppresses thermal backgrounds, but, critically, allows the probing method to mitigate the quantum noise. This approach offers a scalable path forward for axion detection over the ∼(few−200) μ⁢eV mass range—covering the preferred parameter space for the postinflationary Peccei-Quinn axion dark matter—using compact, tunable systems.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗