Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “multiple precision”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 865 records · Page 48

Calcite Twinning in Mollusk Shells and Carrara Marble

Mollusk shells protect the animals that form and inhabit them. They are composites of minerals and organics, with diverse mesostructures, including nacre, prismatic calcite, crossed-lamellar aragonite, and foliated calcite. Twins, that is, crystals mirror symmetric with respect to their coherent interface, occurring as formation or deformation twins, are observed in all mollusk shell mesostructures but never within calcite prisms. Here, nanotwins and microwins within single calcite prisms are observed in different shells. Using Polarization-dependent Imaging Contrast (PIC) mapping with 20–60 nm resolution, twins are observed to be 0.2–3 µm thick layers of differently oriented and colored crystals with respect to the main prism crystal. Multiple twins are interspersed with the prism crystal, parallel to one another, and similarly oriented. When comparing images of calcite prisms and twins obtained by PIC mapping and by Electron Back-Scattered Diffraction (EBSD), the images correspond precisely. All twins are e-twin types, with 127° angular distance between c-axes. E-twins are the most common deformation twins in geologic calcite, as also observed here in Carrara marble. Location of all twins near the outer surface of all shells and e-twin type both suggest that twins within calcite prisms in mollusk shells result from deformation twinning.

36 MATERIALS SCIENCE↗

Facile alignment estimation in carbon nanotube films using image processing

Whether a macroscopic assembly of carbon nanotubes can exhibit the one-dimensional properties expected from individual nanotubes critically depends on how well the nanotubes are aligned inside the assembly. Therefore, a simple and accurate method for assessing the degree of alignment is desired for the rapid characterization of carbon nanotube films and fibers. Here, we present an end-to-end solution for determining the global and local spatial orientation of carbon nanotubes in films within a short amount of time using a fast, precise, and economical approach based on an image processing method applied to scanning electron microscopy images. Further, we first use Laplacian edge enhancement filtering for improving the appearance of edge regions, which is followed by image partitioning into multiple blocks to capture the nanoscale orientation characteristics and total variation-based image decomposition of these image blocks. We then perform a 2D-fast Fourier transform on the image decomposed textural components of these edge-enhanced image blocks to determine the orientation distribution, which is utilized to estimate the 2D nematic order parameter. To show the effectiveness of our method, we corroborated our results against results obtained with other state-of-the-art image processing and experimental techniques.

2D-FFT↗

STEPs-SOL, a Peptoid Force Field Parameterization to Include Solvent Effects

As peptoids (N-substituted glycines) continue to gain popularity as a class of biomimetic polymers, the importance and demand for accurate force fields in molecular simulations also grow. Building on the vacuum-optimized Systematic and Extensible Force Field for Peptoids (STEPs) force field, here we present STEPs-SOL, a novel peptoid force field parametrization that effectively incorporates solvent effects to enhance the accuracy of peptoid simulations. The development of STEPs-SOL is based on the need for precise electrostatic modeling achieved through solvent-specific partial charge optimization. Here, our systematic approach significantly improves agreement with experimental measurements, reducing the mean absolute error in cis/trans ratio predictions (ΔG c/t ) by an average of 38% across multiple peptoid residues and solvent environments. This improved parametrization addresses computational challenges associated with nonbonded energies while maintaining a workflow that relies on high-level quantum mechanical data rather than depending solely on limited experimental equilibrium properties. By evaluating the effects of conformational bias in restrained electrostatic potential (RESP) charge generation and examining their impact on peptoid conformations in various solvents, we enhance our understanding of peptoid structural dynamics while providing a more accurate modeling framework.

force field↗

TDCOSMO XXIII. Measurement of the Hubble constant from the doubly lensed quasar HE 1104−1805

Time-delay cosmography leverages strongly lensed quasars to measure the Universe’s current expansion rate, H 0 , independently from other methods. The latest TDCOSMO milestone measurement primarily used quadruply lensed quasars for their mass profile constraints. However, doubly lensed quasars, being more abundant and offering precise time delays, could expand the sample by a factor of 5, significantly advancing towards a 1% precision measurement of H 0 . We present the first TDCOSMO analysis of a doubly imaged source, HE 1104−1805, including the measurement of the four necessary ingredients. First, by combining 17 years of data from the SMARTS, Euler, and WFI telescopes, we measured a time delay of 176.3 +11.4 −10.3 days. Second, using MUSE data, we extracted stellar velocity dispersion measurements in three radial bins with 5% to 13% precision. Third, employing F160W HST imaging for lens modelling and marginalising over various modelling choices, we measured the Fermat potential difference between the images. Fourth, using wide-field imaging, we measured the convergence added by objects not included in the lens modelling. By combining these four ingredients, we measured the time delay distance and the angular diameter distance to the deflector, favouring a power-law mass model over a baryonic and dark matter composite model. The measurement was performed blindly to prevent experimenter bias and resulted in a Hubble constant of H 0 = +5.8 −5.0 × λ int km s −1 Mpc −1 , where λ int is the internal mass sheet degeneracy parameter. This is in agreement with the TDCOSMO-2025 milestone and its precision for λ int = 1 is comparable to that obtained with the best-observed quadruply lensed quasars (4–6%). This work is a stepping stone towards a precise measurement of H 0 using a large sample of doubly lensed quasars, supplementing the current sample. The next TDCOSMO milestone paper will include this system in its hierarchical analysis, constraining λ int and H 0 jointly with multiple lenses.

cosmological parameters↗

MEASUREMENT OF 21 cm BRIGHTNESS FLUCTUATIONS AT z {approx} 0.8 IN CROSS-CORRELATION

In this Letter, 21 cm intensity maps acquired at the Green Bank Telescope are cross-correlated with large-scale structure traced by galaxies in the WiggleZ Dark Energy Survey. The data span the redshift range 0.6 < z < 1 over two fields totaling {approx}41 deg. sq. and 190 hr of radio integration time. The cross-correlation constrains {Omega}{sub HI} b{sub HI} r = [0.43 {+-} 0.07(stat.) {+-} 0.04(sys.)] Multiplication-Sign 10{sup -3}, where {Omega}{sub HI} is the neutral hydrogen (H I) fraction, r is the galaxy-hydrogen correlation coefficient, and b{sub HI} is the H I bias parameter. This is the most precise constraint on neutral hydrogen density fluctuations in a challenging redshift range. Our measurement improves the previous 21 cm cross-correlation at z {approx} 0.8 both in its precision and in the range of scales probed.

79 ASTRONOMY AND ASTROPHYSICS↗

The California-Kepler Survey. I. High-resolution Spectroscopy of 1305 Stars Hosting Kepler Transiting Planets

The California-Kepler Survey (CKS) is an observational program developed to improve our knowledge of the properties of stars found to host transiting planets by NASA’s Kepler Mission. The improvement stems from new high-resolution optical spectra obtained using HIRES at the W. M. Keck Observatory. The CKS stellar sample comprises 1305 stars classified as Kepler objects of interest, hosting a total of 2075 transiting planets. The primary sample is magnitude-limited (Kp<14.2) and contains 960 stars with 1385 planets. The sample was extended to include some fainter stars that host multiple planets, ultra-short period planets, or habitable zone planets. The spectroscopic parameters were determined with two different codes, one based on template matching and the other on direct spectral synthesis using radiative transfer. We demonstrate a precision of 60 K in T{sub eff}, 0.10 dex in logg, 0.04 dex in [Fe/H], and 1.0 km s{sup −1} in Vsin i. In this paper, we describe the CKS project and present a uniform catalog of spectroscopic parameters. Subsequent papers in this series present catalogs of derived stellar properties such as mass, radius, and age; revised planet properties; and statistical explorations of the ensemble. CKS is the largest survey to determine the properties of Kepler stars using a uniform set of high-resolution, high signal-to-noise ratio spectra. The HIRES spectra are available to the community for independent analyses.

79 ASTRONOMY AND ASTROPHYSICS↗

Microfluidic Cell-based Assays in Stem Cell and Other Rare Cell Type Research

Microfluidics is a technology defined by the engineered precise manipulation of minute amount of liquids through channels with dimensions in the micron scale. Much of microfluidic devices used for biomedical purposes are produced in the form of so called “lab-on-a-chip” format, where multiple steps of conventional biochemical analyses such as staining, washing, and signal collection are miniaturized and integrated into chips fabricated from polymer or glass. Cell-based microfluidic lab-on-achip technology provides some obvious advantages: 1) drastically reduced sample and reagent requirement, and 2) separation and detection with improved sensitivity due to fluid properties at the microscale, i.e. laminar flow. Based on these two advantages, the obvious place where microfluidic cell assays will provide the most benefit is wherescientists must gather much information from precious little sample. Stem cells and other precious cell types such as circulating tumor cells (CTCs), and rare immune subsets are the perfect match for microfluidic multiplex assays. The recent demonstration that multiple cellular changes such as surface receptor activation, protein translocation, long and short RNA, and DNA changes can all be extracted from intact single cells paves the way to systems level understanding of cellular states during development or disease. Finally, with the ability to preserve cell integrity in a microfluidic device during multiplexed analysis, one also preserves the single cell resolution, where information regarding the cell-to-cell heterogeneity during differentiation or response to stimuli is vitally important.

59 BASIC BIOLOGICAL SCIENCES↗

Design and testing of a sensitive heat-flow calorimeter for measuring radioactive waste in 55-gallon (US) drums - 15334

A sensitive large volume calorimeter for measuring the thermal power generated by the radioactive decay of heat producing materials in 55-gallon drums has been developed and tested. The technology is applicable to the measurement of all radionuclides that decay by alpha or beta decay such as waste or product material containing plutonium, tritium and americium. It is also relevant to the measurement of drums where gamma rays from radioactive decay are captured locally in attenuating materials and the resulting rate of thermal energy deposition (sample thermal power) is of sufficient magnitude for a calorimetry measurement. The initial application of the drum calorimeter is for measuring and characterizing plutonium-bearing waste drums. The calorimeter design has optimised the two characteristics of high thermal sensitivity and reduced measurement times. In order to achieve these characteristics for large volume drums, the heat-flow method of operation was chosen in a single measurement chamber configuration. Using a drum-lifting device, the waste drum is positioned on a sliding platform and subsequently moved by the operator inside an octagonal inner chamber, which acts as the heat sink. The heat-sink chamber has significant thermal inertia and remains effectively at a constant temperature throughout the duration of a drum measurement. The octagonal inner measurement chamber is constructed inside a multi-layer external thermal enclosure, which provides both thermal insulation and significant thermal inertia. The external thermal enclosure isolates the measurement process from the effects of changes in the external ambient temperature. During a measurement, heat flows from the drum being measured to the heat sink. This heat-flow is measured by a series of thermopile sensor assemblies, which are positioned between the waste drum and the heat sink. A high sensitivity of greater than 200 μV/mW (microvolts per milliwatt) has been achieved using multiple close-coupled thermopile sensors in each assembly. Reduced measurement times are achieved by positioning the thermopile sensor assemblies close to the drum surface in order to reduce the thermal transport delay. The instrument incorporates a calibrated precision power supply, which requires annual recalibration and is traceable to national standards. It is used to power a calibration heater that has been built into a calibration and test drum. The calibration and test drum is used both to calibrate the instrument and provide periodic confirmation of correct operation. Measurements of calorimeter performance are reported for a range of drum thermal powers. Long-term temperature drift measurements are used to provide estimates of the minimum detectable drum thermal power and hence the minimum detectable activity for both plutonium and tritium. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

MPACT Fast Neutron Multiplicity System Design Concepts

This report documents work performed by Idaho National Laboratory and the University of Michigan in fiscal year (FY) 2012 to examine design parameters related to the use of fast-neutron multiplicity counting for assaying plutonium for materials protection, accountancy, and control purposes. This project seeks to develop a new type of neutron-measurement-based plutonium assay instrument suited for assaying advanced fuel cycle materials. Some current-concept advanced fuels contain high concentrations of plutonium; some of these concept fuels also contain other fissionable actinides besides plutonium. Because of these attributes the neutron emission rates of these new fuels may be much higher, and more difficult to interpret, than measurements made of plutonium-only materials. Fast neutron multiplicity analysis is one approach for assaying these advanced nuclear fuels. Studies have been performed to assess the conceptual performance capabilities of a fast-neutron multiplicity counter for assaying plutonium. Comparisons have been made to evaluate the potential improvements and benefits of fast-neutron multiplicity analyses versus traditional thermal-neutron counting systems. Fast-neutron instrumentation, using for example an array of liquid scintillators such as EJ-309, have the potential to either a) significantly reduce assay measurement times versus traditional approaches, for comparable measurement precision values, b) significantly improve assay precision values, for measurement durations comparable to current-generation technology, or c) moderating improve both measurement precision and measurement durations versus current-generation technology. Using the MCNPX-PoliMi Monte Carlo simulation code, studies have been performed to assess the doubles-detection efficiency for a variety of counter layouts of cylindrical liquid scintillator detector cells over one, two, and three rows. Ignoring other considerations, the best detector design is the one with the most detecting volume. However, operational limitations guide a) the maximum acceptable size of each detector cell (due to PSD performance and maximum-acceptable per-channel data throughput rates, limited by pulse pile-up and the processing rate of the electronics components of the system) and b) the affordability of a system due to the number of total channels of data to be collected and processed. As a first estimate, it appears that a system comprised of two rows of detectors 5" Ø $\times$ 3" would yield a working prototype system with excellent performance capabilities for assaying Pu-containing items and capable of handling high signal rates likely when measuring items with Pu and other actinides. However, it is still likely that gamma-ray shielding will be needed to reduce the total signal rate in the detectors. As a first step prior to working with these larger-sized detectors, it may be practical to perform scoping studies using small detectors, such as already-on-hand 3" Ø $\times$ 3" detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Assessment and Performance of Flexible Quench Antenna Array Diagnostics for Superconducting Magnets

FNAL has been developing multiple versions of flexible quench antennas (flex-QA), including some specially optimized for high sensitivity and/or high resolution, to characterize quench events and transients during current ramping in superconducting magnets. A fundamental feature in our use of these is the creation of grid-like structures of sensitive elements to cover coil surfaces, with the aim of getting precise localization of magnetic flux-change events. The flex-QA are coupled with fast data-acquisition, allowing comprehensive analysis of signals at the relevant fine time scales. In addition to arrays of various flex-QA types being used during cryogenic testing of superconducting magnets, we also are utilizing a newly developed room temperature test stand to better understand QA response characteristics. The data from actual superconducting magnet tests, warm test stand measurements, and simulation data on the same QA designs allows us to draw conclusions on operational feasibility and plan better for improvements of our sensors. In this paper we present data from the multiple tests performed and analysis results. Flex-QA designs are compared, and their features, options, and optimization discussed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measurement of Charged-Pion Production in Deep-Inelastic Scattering off Nuclei with the CLAS Detector

Background: Energetic quarks in nuclear deep-inelastic scattering propagate through the nuclear medium. Processes that are believed to occur inside nuclei include quark energy loss through medium-stimulated gluon bremsstrahlung and intranuclear interactions of forming hadrons. More data are required to gain a more complete understanding of these effects. Purpose: To test the theoretical models of parton transport and hadron formation, we compared their predictions for the nuclear and kinematic dependence of pion production in nuclei. Methods: We have measured charged-pion production in semi-inclusive deep-inelastic scattering off D, C, Fe, and Pb using the CLAS detector and the CEBAF 5.014-GeV electron beam. We report results on the nuclear-to-deuterium multiplicity ratio for π + and π - as a function of energy transfer, four-momentum transfer, and pion energy fraction or transverse momentum—the first three-dimensional study of its kind. Results: The π + multiplicity ratio is found to depend strongly on the pion fractional energy z and reaches minimum values of 0.67 ± 0.03, 0.43 ± 0.02, and 0.27 ± 0.01 for the C, Fe, and Pb targets, respectively. The z dependencies of the multiplicity ratios for π + and π - are equal within uncertainties for C and Fe targets but show differences at the level of 10% for the Pb-target data. The results are qualitatively described by the GIBUU transport model, as well as with a model based on hadron absorption, but are in tension with calculations based on nuclear fragmentation functions. Conclusions: These precise results will strongly constrain the kinematic and flavor dependence of nuclear effects in hadron production, probing an unexplored kinematic region. They will help to reveal how the nucleus reacts to a fast quark, thereby shedding light on its color structure and transport properties and on the mechanisms of the hadronization process.

Moran, S.↗

An Archaeal Immune System Can Detect Multiple Protospacer Adjacent Motifs (PAMs) to Target Invader DNA

The clustered regularly interspaced short palindromic repeat (CRISPR)/CRISPR-associated (Cas) system provides adaptive and heritable immunity against foreign genetic elements in most archaea and many bacteria. Although this system is widespread and diverse with many subtypes, only a few species have been investigated to elucidate the precise mechanisms for the defense of viruses or plasmids. Approximately 90% of all sequenced archaea encode CRISPR/Cas systems, but their molecular details have so far only been examined in three archaeal species: Sulfolobus solfataricus, Sulfolobus islandicus, and Pyrococcus furiosus. Here, we analyzed the CRISPR/Cas system of Haloferax volcanii using a plasmid-based invader assay. Haloferax encodes a type I-B CRISPR/Cas system with eight Cas proteins and three CRISPR loci for which the identity of protospacer adjacent motifs (PAMs) was unknown until now. We identified six different PAM sequences that are required upstream of the protospacer to permit target DNA recognition. This is only the second archaeon for which PAM sequences have been determined, and the first CRISPR group with such a high number of PAM sequences. Cells could survive the plasmid challenge if their CRISPR/Cas system was altered or defective, e.g. by deletion of the cas gene cassette. Experimental PAM data were supplemented with bioinformatics data on Haloferax and Haloquadratum.

59 BASIC BIOLOGICAL SCIENCES↗

High Multiplicity Infection by HIV-1 in Men Who Have Sex with Men

Elucidating virus-host interactions responsible for HIV-1 transmission is important for advancing HIV-1 prevention strategies. To this end, single genome amplification (SGA) and sequencing of HIV-1 within the context of a model of random virus evolution has made possible for the first time an unambiguous identification of transmitted/founder viruses and a precise estimation of their numbers. Here, we applied this approach to HIV-1 env analyses in a cohort of acutely infected men who have sex with men (MSM) and found that a high proportion (10 of 28; 36%) had been productively infected by more than one virus. In subjects with multivariant transmission, the minimum number of transmitted viruses ranged from 2 to 10 with viral recombination leading to rapid and extensive genetic shuffling among virus lineages. A combined analysis of these results, together with recently published findings based on identical SGA methods in largely heterosexual (HSX) cohorts, revealed a significantly higher frequency of multivariant transmission in MSM than in HSX [19 of 50 subjects (38%) versus 34 of 175 subjects (19%); Fisher’s exact p = 0.008]. To further evaluate the SGA strategy for identifying transmitted/founder viruses, we analyzed 239 overlapping 59 and 39 half genome or env-only sequences from plasma viral RNA (vRNA) and blood mononuclear cell DNA in an MSM subject who had a particularly well-documented virus exposure history 3–6 days before symptom onset and 14–17 days before peak plasma viremia (47,600,000 vRNA molecules/ml). All 239 sequences coalesced to a single transmitted/founder virus genome in a time frame consistent with the clinical history, and a molecular clone of this genome encoded replication competent virus in accord with model predictions. Higher multiplicity of HIV-1 infection in MSM compared with HSX is consistent with the demonstrably higher epidemiological risk of virus acquisition in MSM and could indicate a greater challenge for HIV-1 vaccines than previously recognized.

59 BASIC BIOLOGICAL SCIENCES↗

Exploring the NΛ–NΣ coupled system with high precision correlation techniques at the LHC

The interaction of Λ and Σ hyperons (Y) with nucleons (N) is strongly influenced by the coupled-channel dynamics. Due to the small mass difference of the NΛ and NΣ systems, the sizable coupling strength of the NΣ↔NΛ processes constitutes a crucial element in the determination of the NΛ interaction. In this letter we present the most precise measurements on the interaction of pΛ pairs, from zero relative momentum up to the opening of the NΣ channel. The correlation function in the relative momentum space for pΛ ⊕$\bar{p}$$\bar{Λ}$ pairs measured in high-multiplicity triggered pp collisions at $\sqrt{s}$=13 TeV at the LHC is reported. The opening of the inelastic NΣ channels is visible in the extracted correlation function as a cusp-like structure occurring at relative momentum k*=289 MeV/c. This represents the first direct experimental observation of the NΣ↔NΛ coupled channel in the pΛ system. The correlation function is compared with recent chiral effective field theory calculations, based on different strengths of the NΣ↔NΛ transition potential. A weaker coupling, as possibly supported by the present measurement, would require a more repulsive three-body NNΛ interaction for a proper description of the Λ in-medium properties, which has implications on the nuclear equation of state and for the presence of hyperons inside neutron stars.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Automated defect analysis in electron microscopic images

Electron microscopy and defect analysis are a cornerstone of materials science, as they offer detailed insights on the microstructure and performance of a wide range of materials and material systems. Building a robust and flexible platform for automated defect recognition and classification in electron microscopy will result in the completion of analysis orders of magnitude faster after images are recorded, or even online during image acquisition. Automated analysis has the potential to be significantly more efficient, accurate, and repeatable than human analysis, and it can scale with the increasingly important methods of automated data generation. Herein, an automated recognition tool is developed based on a computer vison–based approach; it sequentially applies a cascade object detector, convolutional neural network, and local image analysis methods. We demonstrate that the automated tool performs as well as or better than manual human detection in terms of recall and precision and achieves quantitative image/defect analysis metrics close to the human average. The proposed approach works for images of varying contrast, brightness, and magnification. Furthermore, these promising results suggest that this and similar approaches are worth exploring for detecting multiple defect types and have the potential to locate, classify, and measure quantitative features for a range of defect types, materials, and electron microscopic techniques.

47 OTHER INSTRUMENTATION↗

A multi-point laser Doppler vibrometer with fiber-based configuration

Laser Doppler vibrometer (LDV) is a non-contact optical interferometric system to measure vibrations of structures and machines with a high precision. Normal LDV can only offer a single-point measurement. Scanning LDV is usually impractical to do measurement on transient events. In this paper, a fiber-based self-synchronized multi-point LDV is proposed. The multiple laser beams with different frequency shifts are generated from one laser source. The beams are projected onto a vibrating object, reflected and interfered with a common reference beam. The signal including vibration information of multiple spatial points is captured by one single-pixel photodetector. The optical system is mainly integrated by fiber components for flexibility in measurement. Two experiments are conducted to measure a steady-state simple harmonic vibration of a cantilever beam and a transient vibration of a beam clamped at both ends. In the first measurement, a numerical interpolation is applied to reconstruct the mode shape with increased number of data points. The vibration mode obtained is compared with that from FEM simulation. In transient vibration measurement, the first five resonant frequencies are obtained. The results show the new-reported fiber-based multipoint LDV can offer a vibration measurement on various spatial points simultaneously. With the flexibility of fiber configuration, it becomes more practical for dynamic structural evaluation in industrial areas.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A designed screening study with prespecified combinations of factor settings

In many applications, the experimenter has limited options about what factor combinations can be chosen for a designed study. Consider a screening study for a production process involving five input factors whose levels have been previously established. The goal of the study is to understand the effect of each factor on the response, a variable that is expensive to measure and results in destruction of the part. From an inventory of available parts with known factor values, we wish to identify a best collection of factor combinations with which to estimate the factor effects. Though the observational nature of the study cannot establish a causal relationship involving the response and the factors, the study can increase understanding of the underlying process. The study can also help determine where investment should be made to control input factors during production that will maximally influence the response. Because the factor combinations are observational, the chosen model matrix will be nonorthogonal and will not allow independent estimation of factor effects. In this manuscript we borrow principles from design of experiments to suggest an 'optimal' selection of factor combinations. Specifically, we consider precision of model parameter estimates, the issue of replication, and abilities to detect lack of fit and to estimate two-factor interactions. Through an example, we present strategies for selecting a subset of factor combinations that simultaneously balance multiple objectives, conduct a limited sensitivity analysis, and provide practical guidance for implementing our techniques across a variety of quality engineering disciplines.

42 ENGINEERING↗

DESI 2024 IV: Baryon Acoustic Oscillations from the Lyman alpha forest

We present the measurement of Baryon Acoustic Oscillations (BAO) from the Lyman-α(Lyα) forest of high-redshift quasars with the first-year dataset of the Dark Energy Spectroscopic Instrument (DESI). Our analysis uses over 420 000 Lyα forest spectra and their correlation with the spatial distribution of more than 700 000 quasars. An essential facet of this work is the development of a new analysis methodology on a blinded dataset. We conducted rigorous tests using synthetic data to ensure the reliability of our methodology and findings before unblinding. Additionally, we conducted multiple data splits to assess the consistency of the results and scrutinized various analysis approaches to confirm their robustness. For a given value of the sound horizon (r d ), we measure the expansion at z eff = 2.33 with 2% precision, H(z eff ) = (239.2 ± 4.8) (147.09 Mpc /r d ) km/s/Mpc. Similarly, we present a 2.4% measurement of the transverse comoving distance to the same redshift, DM(z eff ) = (5.84 ± 0.14) (r d /147.09 Mpc) Gpc. Together with other DESI BAO measurements at lower redshifts, these results are used in a companion paper to constrain cosmological parameters.

79 ASTRONOMY AND ASTROPHYSICS↗