Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “loading frequency”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 865 records · Page 48

Three-Dimensional Vibration Isolator for Suppressing High-Frequency Responses for Sage III Contamination Monitoring Package (CMP)

The Stratospheric Aerosol and Gas Experiment (SAGE) III - International Space Station (ISS) instrument will be used to study ozone, providing global, long-term measurements of key components of the Earth's atmosphere for the continued health of Earth and its inhabitants. SAGE III is launched into orbit in an inverted configuration on SpaceX;s Falcon 9 launch vehicle. As one of its four supporting elements, a Contamination Monitoring Package (CMP) mounted to the top panel of the Interface Adapter Module (IAM) box experiences high-frequency response due to structural coupling between the two structures during the SpaceX launch. These vibrations, which were initially observed in the IAM Engineering Development Unit (EDU) test and later verified through finite element analysis (FEA) for the SpaceX launch loads, may damage the internal electronic cards and the Thermoelectric Quartz Crystal Microbalance (TQCM) sensors mounted on the CMP. Three-dimensional (3D) vibration isolators were required to be inserted between the CMP and IAM interface in order to attenuate the high frequency vibrations without resulting in any major changes to the existing system. Wire rope isolators were proposed as the isolation system between the CMP and IAM due to the low impact to design. Most 3D isolation systems are designed for compression and roll, therefore little dynamic data was available for using wire rope isolators in an inverted or tension configuration. From the isolator FEA and test results, it is shown that by using the 3D wire rope isolators, the CMP high-frequency responses have been suppressed by several orders of magnitude over a wide excitation frequency range. Consequently, the TQCM sensor responses are well below their qualification environments. It is indicated that these high-frequency responses due to the typical instrument structural coupling can be significantly suppressed by a vibration passive control using the 3D vibration isolator. Thermal and contamination issues were also examined during the isolator selection period for meeting the SAGE III-ISS instrument requirements.

Li, Y.↗

Algorithms for Determining Physical Responses of Structures Under Load

Ultra-efficient real-time structural monitoring algorithms have been developed to provide extensive information about the physical response of structures under load. These algorithms are driven by actual strain data to measure accurately local strains at multiple locations on the surface of a structure. Through a single point load calibration test, these structural strains are then used to calculate key physical properties of the structure at each measurement location. Such properties include the structure s flexural rigidity (the product of the structure's modulus of elasticity, and its moment of inertia) and the section modulus (the moment of inertia divided by the structure s half-depth). The resulting structural properties at each location can be used to determine the structure s bending moment, shear, and structural loads in real time while the structure is in service. The amount of structural information can be maximized through the use of highly multiplexed fiber Bragg grating technology using optical time domain reflectometry and optical frequency domain reflectometry, which can provide a local strain measurement every 10 mm on a single hair-sized optical fiber. Since local strain is used as input to the algorithms, this system serves multiple purposes of measuring strains and displacements, as well as determining structural bending moment, shear, and loads for assessing real-time structural health. The first step is to install a series of strain sensors on the structure s surface in such a way as to measure bending strains at desired locations. The next step is to perform a simple ground test calibration. For a beam of length l (see example), discretized into n sections and subjected to a tip load of P that places the beam in bending, the flexural rigidity of the beam can be experimentally determined at each measurement location x. The bending moment at each station can then be determined for any general set of loads applied during operation.

Richards, W. Lance↗

Design of a Wideband 900 GHz Balanced Frequency Tripler for Radioastronomy

We report on the design of a fix-tuned split-block waveguide balanced frequency tripler working nominally at 900GHz. It uses a GaAs Schottky planar diode pair in a balanced configuration. The circuit will be fabricated with JPL membrane technology in order to minimize dielectric loading. The multiplier is bias-less to dramatically ease the mounting and the operating procedure. At room temperature, the expected output power is 50- 130 (micro)W in the band 800-970 GHz when the tripler is pumped with 4mW. By modifying the waveguide input and output matching circuit, the multiplier can be tuned to operate at lower frequencies.

Schottky diode multipliers↗

A fiber matrix model for fluid flow and streaming potentials in the canaliculi of an osteon

A theoretical model is developed to predict the fluid shear stress and streaming potential at the surface of osteocytic processes in the lacunar-canalicular porosity of an osteon when the osteon is subject to mechanical loads that are parallel or perpendicular to its axis. The theory developed in Weinbaum et al. (31) for the flow through a proteoglycan matrix in a canaliculus is employed in a poroelastic model for the osteon. Our formulation is a generalization of that of Petrov et al. (17). Our model predicts that, in order to satisfy the measured frequency dependence of the phase and magnitude of the SGP in macroscopic bone samples, the fiber spacing in the fluid annulus must lie in the narrow range 6-7 nm typical of the spacing of GAG sidechains along a protein monomer. The model predictions for the local SGP profiles in the osteon agree with the experimental observations of Starkebaum et al. (24). The theory predicts that the pore pressure relaxation time, tau d, for a 150-300 microns diameter osteon with the foregoing matrix structure is approximately 0.03-0.13 sec, and that the amplitude of the mean fluid shear stress on the membrane of the osteocytic process at the mean areal radius of the osteon has a maximum at 28 Hz if tau d = 0.06 sec. This maximum, which is independent of the magnitude of the loading, could be important in vivo since the recent experiments of Turner et al. (28) and McLeod et al. (15) have a peak in the strain frequency spectrum between 20 and 30 Hz that also appears to be independent of the type (magnitude) of loading. Numerical predictions for the amplitude of the average fluid shear stress on the osteocytic membrane at the mean areal radius of the osteon show that the fluid shear stress associated with the low amplitude 20-30 Hz spectral strain component is at least as large as the average fluid shear stress associated with the high amplitude 1 Hz stride component, although the latter loading is an order of magnitude larger, and has a magnitude that lies within the middle of the range, 6-30 dynes/cm2, where fluid shear stresses in tissue culture studies with osteoblast monolayers have elicited an intracellular Ca++ response (31). The implications of these results for intracellular electrical communication are discussed.

Non-NASA Center↗

Calculation of unsteady small disturbance transonic flow at arbitrary reduced frequency using an extended integral equation method.

A novel analytical-numerical method for calculating unsteady small disturbance transonic flow over airfoils has been developed. The method uses an extended integral equation technique, based on both the velocity potential and the acceleration potential, to predict unsteady aerodynamic loading on airfoils oscillating in subcritical transonic free stream conditions. The formulation is an extension of the work of Sivaneri and Harris (1980) for steady, non-lifting flows and utilizes the linear theory of Landahl (1961) for decoupling of steady and unsteady components. The analytical-numerical procedure involves several intnegrating schemes and applies to general frequencies of oscillations. The technique is illustrated by computing the transonic flow about parabolic arc airfoils. Specific unsteady results for reduced frequencies based on semi-chord of 0.01, 0.1, 0.3, 0.4 and 0.6 are given. Comparison of results with those obtained by an ADI finite difference scheme is made.

Lamah, C. A.↗

A Numerical Analysis of Electromagnetic Scattering from Two-Dimensional Edge Terminations

Several techniques that influence the low frequency scattering from penetrable edge terminations are evaluated using a hybrid finite element and boundary element method code. The edge terminations consist of a dielectric skin forming an exterior shape with an internal conducting bulkhead. Some of the techniques considered are bulkhead shaping, internal material loading, placement of resistive cards, and the placement of lossy dielectric material rods. The intent of the various treatments is to find a combination or combinations that influence(s) the backscattered field to acceptable levels over a range of frequencies for both transverse magnetic and transverse electric polarizations.

Gray, B. E.↗

Circuit performance of a parasitic-loading digital speed controller for a 400-hertz turbine-driven alternator

Parasitic speed controllers are used in space power electrical generating systems to maintain the speed of the turbine-driven alternators within specified limits. Selected subcircuits for a solid state parasitic-loading speed controller were assembled and tested. The test results as obtained to date consist of the performance evaluation of the frequency reference and the period counter subcircuits. These circuits performed as expected.

Ryan, J. P.↗

Electric power processing, distribution and control for advanced aerospace vehicles.

The results of a current study program to develop a rational basis for selection of power processing, distribution, and control configurations for future aerospace vehicles including the Space Station, Space Shuttle, and high-performance aircraft are presented. Within the constraints imposed by the characteristics of power generation subsystems and the load utilization equipment requirements, the power processing, distribution and control subsystem can be optimized by selection of the proper distribution voltage, frequency, and overload/fault protection method. It is shown that, for large space vehicles which rely on static energy conversion to provide electric power, high-voltage dc distribution (above 100 V dc) is preferable to conventional 28 V dc and 115 V ac distribution per MIL-STD-704A. High-voltage dc also has advantages over conventional constant frequency ac systems in many aircraft applications due to the elimination of speed control, wave shaping, and synchronization equipment.

Krausz, A.↗

Weight optimization of ultra large space structures

The paper describes the optimization of a solar power satellite structure for minimum mass and system cost. The solar power satellite is an ultra large low frequency and lightly damped space structure; derivation of its structural design requirements required accommodation of gravity gradient torques which impose primary loads, life up to 100 years in the rigorous geosynchronous orbit radiation environment, and prevention of continuous wave motion in a solar array blanket suspended from a huge, lightly damped structure subject to periodic excitations. The satellite structural design required a parametric study of structural configurations and consideration of the fabrication and assembly techniques, which resulted in a final structure which met all requirements at a structural mass fraction of 10%.

Reinert, R. P.↗

Acoustic Levitator Maintains Resonance

Transducer loading characteristics allow resonance tracked at high temperature. Acoustic-levitation chamber length automatically adjusted to maintain resonance at constant acoustic frequency as temperature changes. Developed for containerless processing of materials at high temperatures, system does not rely on microphones as resonance sensors, since microphones are difficult to fabricate for use at temperatures above 500 degrees C. Instead, system uses acoustic transducer itself as sensor.

Barmatz, M. B.↗

Structural and aeroelastic analysis of the SR-7L propfan

A structural and aeroelastic analysis of a large scale advanced turboprop rotor blade is presented. This 8-blade rotor is designed to operate at Mach 0.8 at an altitude of 35,000 ft. The blades are highly swept and twisted and of spar/shell construction. Due to the complexity of the blade geometry and its high performance, it is subjected to much higher loads and tends to be much less stable than conventional blades. Four specific analyses were conducted: (1) steady deflection; (2) natural frequencies and mode shapes; (3) steady stresses; and (4) aeroelastic stability. State-of-the-art methods were used to analyze the blades including a large deflection, finite element structural analysis, and an aeroelastic analysis including interblade aerodynamic coupling (cascade effects). The study found the blade to be structurally sound and aeroelastically stable. However, it clearly indicated that advanced turboprop blades are much less robust than conventional blades and must be analyzed and fabricated much more carefully in order to assure that they are structurally sound and aeroelastically stable.

Hirschbein, Murray↗

Structural optimization and recent large ground antenna installations

Within the past several years, the Jet Propulsion Laboratory has designed and built major ground antenna structures in Spain, Australia, and California. One of the antennas at each location is a 70 meter-diameter structure that is a retrofit of the existing 64 meter antenna. The 64 meter existing antennas were first stripped back to a 34 meter interior and then completely new construction with deeper trusses was added to extend the interior to 70 meters. The 70 meter project included the rare opportunity to collect field data to compare with predictions of the finite-element analytical models. The new quadripod design was tested for its lower mode natural frequencies and the main reflector was measured by theodolite to determine deflections of subsets of the backup-structure deformations under load. The emphasis here is to examine measurement results and possibly provide some appreciation of the relationship of predictions made from the design model to actual measurements.

Levy, Roy↗

Active control of tiltrotor blade in-plane loads during maneuvers

The origin of one/rev rotor aerodynamic loads which arise in tiltrotor aircraft during airplane-mode high speed pull-up and push-over maneuvers is examined using a coupled rotor/fuselage dynamic simulation. A modified eigenstructure assignment technique is used to design a controller which alleviates the in-plane loads during high pitch rate maneuvers. The controller utilizes rotor cyclic pitch inputs to restructure the aircraft short period and phugoid responses in order to achieve the coupling between pitch rate and rotor flapping responses which minimizes the rotor aerodynamic loading. Realistic time delays in the feedback path are considered during the controller design. Stability robustness in the presence of high frequency modeling errors is ensured through the use of singular value analysis.

Miller, David G.↗

Nonlinear vibrations of thin arbitrarily laminated composite plates subjected to harmonic excitations using DKT elements

A finite element formulation is presented for determining the large-amplitude free and steady-state forced vibration response of arbitrarily laminated anisotropic composite thin plates using the Discrete Kirchhoff Theory (DKT) triangular elements. The nonlinear stiffness and harmonic force matrices of an arbitrarily laminated composite triangular plate element are developed for nonlinear free and forced vibration analyses. The linearized updated-mode method with nonlinear time function approximation is employed for the solution of the system nonlinear eigenvalue equations. The amplitude-frequency relations for convergence with gridwork refinement, triangular plates, different boundary conditions, lamination angles, number of plies, and uniform versus concentrated loads are presented.

Chiang, C. K.↗

Response of launch pad structures to random acoustic excitation

Two solutions (probabilistic and deterministic) for the random vibration problem are presented in this paper from the standpoint of their applicability to predict the response of ground structures subjected to acoustic loading during the launch of a Space Shuttle. Deficiencies of the probabilistic method, especially to predict response in the low-frequency regime, prompted the development of the deterministic analysis, which offers a valid alternative. Challenges associated with the implementation of these response solutions in a commercially available Finite Element Method (FEM) code are briefly addressed.

Margasahayam, Ravi↗

A Single-Block TRL Test Fixture for the Cryogenic Characterization of Planar Microwave Components

The High-Temperature-Superconductivity (HTS) group of the RF Technology Branch, Space Electronics Division, is actively involved in the fabrication and cryogenic characterization of planar microwave components for space applications. This process requires fast, reliable, and accurate measurement techniques not readily available. A new calibration standard/test fixture that enhances the integrity and reliability of the component characterization process has been developed. The fixture consists of 50 omega thru, reflect, delay, and device under test gold lines etched onto a 254 microns (0.010 in) thick alumina substrate. The Thru-Reflect-Line (TRL) fixture was tested at room temperature using a 30 omega, 7.62 mm (300 mil) long, gold line as a known standard. Good agreement between the experimental data and the data modelled using Sonnet's em(C) software was obtained for both the return (S(sub 11)) and insertion (S( 21)) losses. A gold two-pole bandpass filter with a 7.3 GHz center frequency was used as our Device Under Test (DUT), and the results compared with those obtained using a Short-Open-Load-Thru (SOLT) calibration technique.

Mejia, M.↗

Wave Activity in Europa's Wake: Implications for Ion Pickup

Intense wave power at frequencies near and below the cyclotron frequencies of heavy ions was detected in Europa's wake during the E11 and E15 flybys. The fluctuations are mainly transverse to the background magnetic field. Wave characteristics indicate that they are ion cyclotron waves driven by positively charged pickup ions. In both flybys there is evidence, derived from the wave polarization, for pickup of negatively charged chlorine ions. When the moon is near the center of the Jovian current sheet, the pickup rate inferred for the E15 flyby is larger than that for the E11 flyby, when the moon is outside the Jovian current sheet. The wave power does not provide exact pickup density values because the waves are observed in regions where their growth has not yet fully developed. At the edges of the wake region, low-frequency (< K+ gyrofrequency) magnetohydrodynamic waves are also present. We identify magnetic field signatures that are reminiscent of interchange/ballooning of mass-loaded flux tubes from the wake/pickup region expanding into ambient medium that is less dense.

Volwerk, M.↗

Reduced In-Plane, Low Frequency Helicopter Noise of an Active Flap Rotor

Results from a recent joint DARPA/Boeing/NASA/Army wind tunnel test demonstrated the ability to reduce in-plane, low frequency noise of the full-scale Boeing-SMART rotor using active flaps. Test data reported in this paper illustrated that acoustic energy in the first six blade-passing harmonics could be reduced by up to 6 decibels at a moderate airspeed, level flight condition corresponding to advance ratio of 0.30. Reduced noise levels were attributed to selective active flap schedules that modified in-plane blade airloads on the advancing side of the rotor, in a manner, which generated counteracting acoustic pulses that partially offset the negative pressure peaks associated with in-plane, steady thickness noise. These favorable reduced-noise operating states are a strong function of the active flap actuation amplitude, frequency and phase. The associated noise reductions resulted in reduced aural detection distance by up to 18%, but incurred significant vibratory load penalties due to increased hub shear forces. Small reductions in rotor lift-to-drag ratios, of no more than 3%, were also measured

Sim, Ben W.↗