Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “light source”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 865 records · Page 48

Preparation and characterization of mesoporous N-doped and sulfuric acid treated anatase TiO{sub 2} catalysts and their photocatalytic activity under UV and Vis illumination

Nitrogen-doped TiO{sub 2} catalysts were prepared by a precipitation method. The samples were calcined at 400 deg. C for 4 h in air. X-ray diffraction (XRD), X-ray photoelectron spectroscopy (XPS), low temperature N{sub 2}-adsorption was used for structural characterization and UV-diffuse reflectance (UV-DR) was applied to investigate the optical properties of the as-prepared samples. It was found that microporous N-doped catalysts have solely anatase crystalline structure. Acidic treatment of the calcined samples was performed using sulfuric acid agitation. The crystalline structure remained unchanged due to surface treatment, while the porosity and the surface areas (a{sub BET}{sup S}) were decreased dramatically. Optical characterization of the doped catalysts showed that they could be excited by visible light photons in the 400-500 nm wavelength range (lambda{sub g,1}={approx}390 nm, lambda{sub g,2}={approx}510 nm). It was also established that surface treatment enhances the Vis-light absorption of the N-TiO{sub 2} powders. Finally the catalysts were tested in the photocatalytic degradation of phenol in aqueous suspensions. Two different light sources were used; one of them was a UV-rich high pressure Hg-lamp, while the other was a tubular visible light source. We found that using visible light illumination N-doped, acid treated TiO{sub 2} samples were more catalytically active than non-doped TiO{sub 2} catalysts. - Graphical abstract: The effect of the acid treatment on the visible-light-driven photocatalytic activity of the N-doped, anatase TiO{sub 2} catalysts.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Imaging ultrafast excited state pathways in transition metal complexes by X-ray transient absorption and scattering using X-ray free electron laser source

This report will describe our recent studies of transition metal complex structural dynamics on the fs and ps time scales using an X-ray free electron laser source, Linac Coherent Light Source (LCLS). Ultrafast XANES spectra at the Ni K-edge of nickel(II) tetramesitylporphyrin (NiTMP) were successfully measured for optically excited state at a timescale from 100 fs to 50 ps, providing insight into its sub-ps electronic and structural relaxation processes. Importantly, a transient reduced state Ni(I) (π, 3dx2-y2) electronic state is captured through the interpretation of a short-lived excited state absorption on the low-energy shoulder of the edge, which is aided by the computation of X-ray transitions for postulated excited electronic states. The observed and computed inner shell to valence orbital transition energies demonstrate and quantify the influence of electronic configuration on specific metal orbital energies. A strong influence of the valence orbital occupation on the inner shell orbital energies indicates that one should not use the transition energy from 1s to other orbitals to draw conclusions about the d-orbital energies. For photocatalysis, a transient electronic configuration could influence d-orbital energies up to a few eV and any attempt to steer the reaction pathway should account for this to ensure that external energies can be used optimally in driving desirable processes. NiTMP structural evolution and the influence of the porphyrin macrocycle conformation on relaxation kinetics can be likewise inferred from this study.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Resonance Excitation of Photoluminescence in an Aqueous Uranyl Chloride Solution

We have measured photoluminescence spectra of an aqueous uranyl chloride solution under excitation by various light sources: semiconductor light-emitting diodes and cw laser. The excitation wavelength lay within a resonance absorption band of uranyl chloride, which ensured photoluminescence detection at exposure times of 10{sup –3} s using an extremely small volume of the substance (10{sup –9} cm{sup 3}). The photoluminescence spectra were measured using a small minispectrometer, which allowed us to analyze the spectra in the range 200–1000 nm.

36 MATERIALS SCIENCE↗

Author Contribution to the Pu Handbook II: Chapter 37 LLNL Integrated Sample Preparation Glovebox (TEM) Section

The development of our Integrated Actinide Sample Preparation Laboratory (IASPL) commenced in 1998 driven by the need to perform transmission electron microscopy studies on naturally aged plutonium and its alloys looking for the microstructural effects of the radiological decay process (1). Remodeling and construction of a laboratory within the Chemistry and Materials Science Directorate facilities at LLNL was required to turn a standard radiological laboratory into a Radiological Materials Area (RMA) and Radiological Buffer Area (RBA) containing type I, II and III workplaces. Two inert atmosphere dry-train glove boxes with antechambers and entry/exit fumehoods (Figure 1), having a baseline atmosphere of 1 ppm oxygen and 1 ppm water vapor, a utility fumehood and a portable, and a third double-walled enclosure have been installed and commissioned. These capabilities, along with highly trained technical staff, facilitate the safe operation of sample preparation processes and instrumentation, and sample handling while minimizing oxidation or corrosion of the plutonium. In addition, we are currently developing the capability to safely transfer small metallographically prepared samples to a mini-SEM for microstructural imaging and chemical analysis. The gloveboxes continue to be the most crucial element of the laboratory allowing nearly oxide-free sample preparation for a wide variety of LLNL-based characterization experiments, which includes transmission electron microscopy, electron energy loss spectroscopy, optical microscopy, electrical resistivity, ion implantation, X-ray diffraction and absorption, magnetometry, metrological surface measurements, high-pressure diamond anvil cell equation-of-state, phonon dispersion measurements, X-ray absorption and emission spectroscopy, and differential scanning calorimetry. The sample preparation and materials processing capabilities in the IASPL have also facilitated experimentation at world-class facilities such as the Advanced Photon Source at Argonne National Laboratory, the European Synchrotron Radiation Facility in Grenoble, France, the Stanford Synchrotron Radiation Facility, the National Synchrotron Light Source at Brookhaven National Laboratory, the Advanced Light Source at Lawrence Berkeley National Laboratory, and the Triumph Accelerator in Canada.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Passive microfluidic array card and reader

A microfluidic array card and reader system for analyzing a sample. The microfluidic array card includes a sample loading section for loading the sample onto the microfluidic array card, a multiplicity of array windows, and a transport section or sections for transporting the sample from the sample loading section to the array windows. The microfluidic array card reader includes a housing, a receiving section for receiving the microfluidic array card, a viewing section, and a light source that directs light to the array window of the microfluidic array card and to the viewing section.

47 OTHER INSTRUMENTATION↗

Catheter based mid-infrared reflectance and reflectance generated absorption spectroscopy

A method of characterizing conditions in a tissue, by (a) providing a catheter that has a light source that emits light in selected wavenumbers within the range of mid-IR spectrum; (b) directing the light from the catheter to an area of tissue at a location inside a blood vessel of a subject; (c) collecting light reflected from the location and generating a reflectance spectra; and (d) comparing the reflectance spectra to a reference spectra of normal tissue, whereby a location having an increased number of absorbance peaks at said selected wavenumbers indicates a tissue inside the blood vessel containing a physiological marker for atherosclerosis.

60 APPLIED LIFE SCIENCES↗

Localized surface plasmon resonance mercury detection system and methods

A mercury detection system that includes a flow cell having a mercury sensor, a light source and a light detector is provided. The mercury sensor includes a transparent substrate and a submonolayer of mercury absorbing nanoparticles, e.g., gold nanoparticles, on a surface of the substrate. Methods of determining whether mercury is present in a sample using the mercury sensors are also provided. The subject mercury detection systems and methods find use in a variety of different applications, including mercury detecting applications.

36 MATERIALS SCIENCE↗

Diagnostic system for measuring temperature, pressure, CO2 concentration and H2O concentration in a fluid stream

A diagnostic system for measuring temperature, pressure, CO.sub.2 concentration and H.sub.2O concentration in a fluid stream is described. The system may include one or more probes that sample the fluid stream spatially, temporally and over ranges of pressure and temperature. Laser light sources are directed down pitch optical cables, through a lens and to a mirror, where the light sources are reflected back, through the lens to catch optical cables. The light travels through the catch optical cables to detectors, which provide electrical signals to a processer. The processer utilizes the signals to calculate CO.sub.2 concentration based on the temperatures derived from H.sub.2O vapor concentration. A probe for sampling CO.sub.2 and H.sub.2O vapor concentrations is also disclosed. Various mechanical features interact together to ensure the pitch and catch optical cables are properly aligned with the lens during assembly and use.

47 OTHER INSTRUMENTATION↗

Diagnostic system for measuring temperature, pressure, CO.sub.2 concentration and H.sub.2O concentration in a fluid stream

A diagnostic system for measuring temperature, pressure, CO.sub.2 concentration and H.sub.2O concentration in a fluid stream is described. The system may include one or more probes that sample the fluid stream spatially, temporally and over ranges of pressure and temperature. Laser light sources are directed down pitch optical cables, through a lens and to a mirror, where the light sources are reflected back, through the lens to catch optical cables. The light travels through the catch optical cables to detectors, which provide electrical signals to a processer. The processer utilizes the signals to calculate CO.sub.2 concentration based on the temperatures derived from H.sub.2O vapor concentration. A probe for sampling CO.sub.2 and H.sub.2O vapor concentrations is also disclosed. Various mechanical features interact together to ensure the pitch and catch optical cables are properly aligned with the lens during assembly and use.

42 ENGINEERING↗

Linear Optics From Closed Orbits (LOCO): An Introduction

The LOCO code is used to find and correct errors in the linear optics of storage rings. The original FORTRAN code was written to correct the optics of the NSLS X-Ray ring, and was applied soon thereafter to debug problems with the ALS optics. The ideas used in the code were developed from previous work at SLAC. Several years ago, LOCO was rewritten in MATLAB. As described in this newsletter, the MATLAB version includes a user-friendly interface, with many useful fitting and analysis options. LOCO has been used at many accelerators. Presently, a search for LOCO in the text of papers on the Joint Accelerator Conferences Website yields 107 papers. A comprehensive survey of applications will not be included here. Details of recent results at a few light sources are included in this newsletter. In the past, the quality of LOCO fitting results varied significantly, depending on the storage ring. In particular, the results were mixed for colliding beam facilities, where there tend to be fewer BPMs that in light sources. Fitting rings with less BPM data to constrain the fit optics parameters often led to unreasonably large fit quadrupole gradient variations. Recently, modifications have been made to the LOCO fitting algorithm which leads to much better results when the BPM data does not tightly constrain the fit parameters. The modifications are described in this newsletter, and an example of results with this new algorithm is included.

43 PARTICLE ACCELERATORS↗

The VUV/IR/THz Free Electron Laser Program at Jefferson Lab

Jefferson Lab operates a pair of oscillator-based continuous-wave Free Electron Lasers (FELs) as a linac-based next generation light source with pulse repetition rates up to 75 MHz. The facility uses an energy recovered linac design for efficiency of operation. Recent advances in superconducting technology have been implemented to produce higher acceleration gradients in the linac to produce higher electron beam energies that result in higher photon energies. Thus, while the system originally operated only in the IR, it now covers the photon energy range from the UV to THz, with harmonics upwards of 10 eV with an average spectral flux that is calculated to be 5x10 17 photons/sec/0.1%BW. Pulse lengths are in the sub-picosecond regime, and the fully coherent nature of the source, both transversely and longitudinally, results in peak and average brightness values that are several orders of magnitude higher than storage rings. The system provides an R&D test-bed for studies of electron beam dynamics in a regime appropriate for next generation light sources operating at MHz repetition rates.

43 PARTICLE ACCELERATORS↗

APS Science 2020 (Vol. 2)

The U.S. Department of Energy's Advanced Photn Source (APS) is one of the world’s most productive x-ray light source facilities. Each year, the APS provides high-brightness x-ray beams to a diverse community of more than 5,000 researchers in materials science, chemistry, condensed matter physics, the life and environmental sciences, and applied research. Researchers using the APS produce over 2,000 publications each year detailing impactful discoveries, and solve more vital biological protein structures than users of any other x-ray light source research facility. APS x-rays are ideally suited for explorations of materials and biological structures; elemental distribution; chemical, magnetic, electronic states; and a wide range of technologically important engineering systems from batteries to fuel injector sprays, all of which are the foundations of our nation’s economic, technological, and physical well-being. The APS occupies an 80-acre site on the Argonne campus, about 25 miles from downtown Chicago, Illinois. It shares a site with the Center for Nanoscale Materials and the Advanced Protein Characterization Facility.

01 COAL, LIGNITE, AND PEAT↗

APS Science 2020 (Vol. 1)

The U.S. Department of Energy's Advanced Photon Source (APS) is one of the world’s most productive x-ray light source facilities. Each year, the APS provides high-brightness x-ray beams to a diverse community of more than 5,000 researchers in materials science, chemistry, condensed matter physics, the life and environmental sciences, and applied research. Researchers using the APS produce over 2,000 publications each year detailing impactful discoveries, and solve more vital biological protein structures than users of any other x-ray light source research facility. APS x-rays are ideally suited for explorations of materials and biological structures; elemental distribution; chemical, magnetic, electronic states; and a wide range of technologically important engineering systems from batteries to fuel injector sprays, all of which are the foundations of our nation’s economic, technological, and physical well-being. The APS occupies an 80-acre site on the Argonne campus, about 25 miles from downtown Chicago, Illinois. It shares a site with the Center for Nanoscale Materials and the Advanced Protein Characterization Facility.

25 ENERGY STORAGE↗

Experimental Definition and Validation of Protein Coding Transcripts in Chlamydomonas reinhardtii

Algal fuel sources promise unsurpassed yields in a carbon neutral manner that minimizes resource competition between agriculture and fuel crops. Many challenges must be addressed before algal biofuels can be accepted as a component of the fossil fuel replacement strategy. One significant challenge is that the cost of algal fuel production must become competitive with existing fuel alternatives. Algal biofuel production presents the opportunity to fine-tune microbial metabolic machinery for an optimal blend of biomass constituents and desired fuel molecules. Genome-scale model-driven algal metabolic design promises to facilitate both goals by directing the utilization of metabolites in the complex, interconnected metabolic networks to optimize production of the compounds of interest. Using Chlamydomonas reinhardtii as a model, we developed a systems-level methodology bridging metabolic network reconstruction with annotation and experimental verification of enzyme encoding open reading frames. We reconstructed a genome-scale metabolic network for this alga and devised a novel light-modeling approach that enables quantitative growth prediction for a given light source, resolving wavelength and photon flux. We experimentally verified transcripts accounted for in the network and physiologically validated model function through simulation and generation of new experimental growth data, providing high confidence in network contents and predictive applications. The network offers insight into algal metabolism and potential for genetic engineering and efficient light source design, a pioneering resource for studying light-driven metabolism and quantitative systems biology. Our approach to generate a predictive metabolic model integrated with cloned open reading frames, provides a cost-effective platform to generate metabolic engineering resources. While the generated resources are specific to algal systems, the approach that we have developed is not specific to algae and can be readily expanded to other microbial systems as well as higher plants and animals.

09 BIOMASS FUELS↗

Light-emitting nanocomposites on the basis of ZnS:Cu deposited into porous anodic Al{sub 2}O{sub 3} matrices

A new nanocomposite material, specifically, copper-doped zinc sulfide deposited by vacuum thermal sputtering into anodic aluminum-oxide matrices is proposed for the production of promising electroluminescent light sources. The structure of the chemical bonds is studied, which makes it possible to determine the mechanisms responsible for ultraviolet photoluminescence and electroluminescence of the materials in an electric field at a voltage amplitude of 220 V and frequency of 50 Hz. This will allow the use of the nanocomposite in electroluminescent light sources connected to the standard electrical network.

36 MATERIALS SCIENCE↗

Engineering Super–Poissonian Photon Statistics of Spatial Light Modes

The nature of light sources is defined by the statistical fluctuations of the electromagnetic field. As such, the photon statistics of light sources are typically associated with distinct emitters. Here, the possibility of producing light beams with various photon statistics through the spatial modulation of coherent light is demonstrated. This is achieved by the sequential encoding of controllable Kolmogorov phase screens in a digital micromirror device. Interestingly, the flexibility of this scheme allows for the shaping of spatial light modes with engineered photon statistics at different spatial positions. The performance of this scheme is assessed through the photon-number-resolving characterization of different families of spatial light modes with engineered photon statistics. Furthermore, it is believed that the possibility of controlling the photon fluctuations of the light field at arbitrary spatial locations has important implications for quantum spectroscopy, sensing, and imaging.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

NSLS-II Control of Dynamic Aperture

We have outlined how, by an intuitive approach, the on- and off-momentum dynamic aperture for a synchrotron light source can be estimated from a nonlinear system of algebraic equations for the sextupole/multipole strengths. The approach has only two free parameters: the relative weight for resonance vs. tune shift terms and the tune footprint for stable trajectories in a modern third generation synchrotron light source. In other words, we have established a control theory approach for the medium term (10{sup 3} turns) stability for a dynamic system described by a nonlinear system of ordinary differential equations. Equipped with a predictive, quantitative model for stability, we have then evaluated how to improve the control of the dynamics by analyzing and modifying the properties of the corresponding algebraic system. In particular, by changing the number- and characteristics of the parameters, i.e., we have not evaluated how the underlying (linear) optics could be improved. We have also validated our conjectures by numerical simulations with a realistic model. Presumably, our conclusions, summarized in Section 1.0, are a direct result of the presented analysis and observations.

43 PARTICLE ACCELERATORS↗

Flexibility in the Design of the NSLS-II Lattice

The NSLS-II light source is a proposed 3 GeV storage ring, with the potential for ultra-low emittance [1]. The lattice design uses a 30 cell DBA structure with a periodicity of 15, with alternating long and short straight sections. All cells are tuned achromatic to maximize the emittance reduction achieved as damping wigglers are added to the ring. Recent optimization of the lattice consisted of increasing the number of possible hard X-ray beam ports using three pole wigglers, reducing the number of magnets (quadrupoles and sextupoles) and shifting the magnets to allow easier extraction of the photon beams. The impact of the reduction of magnets on the lattice flexibility will be presented in terms of the tuning range possible for the lattice parameters: tune, emittance, chromaticity, and beta function matching to user insertion devices (IDs). This flexibility is important for optimizing the lattice linear and nonlinear properties, the dynamic aperture, and its impact on beam lifetime, as well as matching the user source requirements and for value engineering of magnets and power supplies.

43 PARTICLE ACCELERATORS↗