Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “light pulses”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 865 records · Page 48

A Possible Magnetar Nature for IGR J16358-4726

We present detailed spectral and timing analysis of the hard x-ray transient IGR J16358-4726 using multi-satellite archival observations. A study of the source flux time history over 6 years, suggests that this transient outbursts can be occurring in intervals of at most 1 year. Joint spectral fits using simultaneous Chandra/ACIS and INTEGRAL/ISGRI data reveal a spectrum well described by an absorbed cut-off power law model plus an Fe line. We detected the pulsations initially reported using Chandra/ACIS also in the INTEGRAL/ISGRI light curve and in subsequent XMM-Newton observations. Using the INTEGRAL data we identified a pulse spin up of 94 s (P = 1.6 x 10(exp -4), which strongly points to a neutron star nature for IGR J16358-4726. Assuming that the spin up is due to disc accretion, we estimate that the source magnetic field ranges between 10(sup 13) approximately 10(sup 15) depending on its distance, possibly supporting a magnetar nature for IGR J16358-4726.

Patel, S.↗

Light-induced dimension crossover dictated by excitonic correlations

In low-dimensional systems with strong electronic correlations, the application of an ultrashort laser pulse often yields novel phases that are otherwise inaccessible. The central challenge in understanding such phenomena is to determine how dimensionality and many-body correlations together govern the pathway of a non-adiabatic transition. To this end, we examine a layered compound, 1T-TiSe 2 , whose three-dimensional charge-density-wave (3D CDW) state also features exciton condensation due to strong electron-hole interactions. We find that photoexcitation suppresses the equilibrium 3D CDW while creating a nonequilibrium 2D CDW. Remarkably, the dimension reduction does not occur unless bound electron-hole pairs are broken. This relation suggests that excitonic correlations maintain the out-of-plane CDW coherence, settling a long-standing debate over their role in the CDW transition. Our findings demonstrate how optical manipulation of electronic interaction enables one to control the dimensionality of a broken-symmetry order, paving the way for realizing other emergent states in strongly correlated systems.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Minimization of thermal deformation in crystal optics for high repetition-rate FEL

Minimizing thermal deformation in X-ray crystal optics is crucial for preserving coherence and wavefront in high-repetition-rate free-electron lasers (FELs). This study presents two approaches to reduce pulse-by-pulse transient thermal deformation in diamond crystals used in cavity-based X-ray FELs (CBXFELs): (1) cryogenic cooling with liquid nitrogen (LN₂), and (2) second-order correction via focusing optics. We revisit the temperature-dependent thermal-mechanical properties of diamond and silicon, implement a finite-element analysis (FEA) method to accelerate convergence to a quasisteady-state regime. Results show that LN₂-cooled diamond crystals meet the stringent deformation requirement of less than 15 pm RMS for the pulse at mJ scale at 1 MHz repetition frequency, and up to 1.5 mJ for 100 kHz. Second-order correction by using focusing elements within the cavity can reduce the impact of thermal deformation for both liquid nitrogen and water cooling.

free electron laser↗

Multiple-core-hole resonance spectroscopy with ultraintense X-ray pulses

Understanding the interaction of intense, femtosecond X-ray pulses with heavy atoms is crucial for gaining insights into the structure and dynamics of matter. One key aspect of nonlinear light–matter interaction was, so far, not studied systematically at free-electron lasers—its dependence on the photon energy. Here, we use resonant ion spectroscopy to map out the transient electronic structures occurring during the complex charge-up pathways of xenon. Massively hollow atoms featuring up to six simultaneous core holes determine the spectra at specific photon energies and charge states. We also illustrate how different X-ray pulse parameters, which are usually intertwined, can be partially disentangled. The extraction of resonance spectra is facilitated by the possibility of working with a constant number of photons per X-ray pulse at all photon energies and the fact that the ion yields become independent of the peak fluence beyond a saturation point. Our study lays the groundwork for spectroscopic investigations of transient atomic species in exotic, multiple-core-hole states that have not been explored previously.

74 ATOMIC AND MOLECULAR PHYSICS↗

Characterization of neurospora circadian rhythms in space

To determine whether the circadian rhythm of conidiation in neurospora crassa is endogenously derived or is driven by some geophysical time cue, an experiment was conducted on space shuttle flight STS-9, where inoculated race tubes were exposed to the microgravity environment of space. The results demonstated that the rhythm can persist in space. However, there were several minor alterations noted; an increase in the period of the oscillation and the variability of the growth rate and a diminished rhythm amplitude, which eventually damped out in 25% of the flight tubes. On day seven of the flight, the tubes were exposed to light while their growth fronts were marked. It appears that some aspects of this marking process reinstated a robust rhythm in all the tubes which continued throughout the remainder of the flight. It was hypothesized that the damping found prior to the marking procedure on STS-9 may have been a result of the hypergravity pulse of launch and not due to the microgravity of the orbital lab; furthermore, that the marking procedure, by exposing the samples to light, had reinstated rhythmicity. To test this, an investigation was conducted into the effects of acute and chronic exposure to hypergravity.

Ferraro, James S.↗

Pulse Profiles, Accretion Column Dips and a Flare in GX 1+4 During a Faint State

The Rossi X-ray Timing Explorer (RXTE) spacecraft observed the X-ray GX 1+4 for it period of 34 hours on July 19/20 1996. The source faded front an intensity of approximately 20 mcrab to a minimum of <= 0.7 mcrab and then partially recovered towards the end of the observation. This extended minimum lasted approximately 40,000 seconds. Phase folded light curves at a barycentric rotation period of 124.36568 +/- 0.00020 seconds show that near the center of the extended minimum the source stopped pulsing in the traditional sense but retained a weak dip feature at the rotation period. Away from the extended minimum the dips are progressively narrower at higher energies and may be interpreted as obscurations or eclipses of the hot spot by the accretion column. The pulse profile changed from leading-edge bright before the extended minimum to trailing-edge bright after it. Data from the Burst and Transient Source Experiment (BATSE) show that a torque reversal occurred < 10 days after our observation. Our data indicate that the observed rotation departs from a constant period with a P/P value of approximately -1.5% per year at a 4.5sigma significance. We infer that we may have serendipitously obtained data, with high sensitivity and temporal resolution about the time of an accretion disk spin reversal. We also observed a rapid flare which had some precursor activity close to the center of the extended minimum.

Giles, A. B.↗

Determination of cytoplasmic calcium concentration in Dryopteris spores: a developmentally non-disruptive technique for loading of the calcium indicator fura-2

Germination of Dryopteris spores is mediated by the physiologically active, far-red-absorbing form of phytochrome, Pfr, and external Ca2+ is necessary for the transduction of the light signal. Because knowledge about the cytoplasmic calcium ion concentration, [Ca2+]i, is of great importance for understanding the role of calcium during signal transduction, this value was measured using fura-2 in fern spores undergoing the normal developmental progression into germination. Fura-2 was loaded into the spores by electroporation, which does not disrupt the normal process of germination. The intensity of the fluorescence emission of the loaded fura-2 was analysed by a microspectrophotometric assay of single spores, and successful loading could be obtained by the application of ten electrical pulses (field strength 7.5 kV cm-1, half-life (time constant) 230 microseconds). Fura-2 was alternately excited by light of wavelengths 355 and 385 nm through an inverted fluorescence microscope, and the emitted fura-2 fluorescence was collected by a silicon-intensified video camera. The cytoplasmic calcium ion concentration was calculated from the ratio of the camera output obtained for both wavelengths and displayed by a pseudo-color technique. Spores responded to changes of the extracellular Ca2+ concentration, and this observation is considered as evidence that fura-2 is loaded into the cytoplasm. The substitution of a low external [Ca2+] (1 mM ethyleneglycol-bis(2-aminoethylether)-N,N,N',N'-tetraacetic acid (EGTA)) by 1 mM CaCl2 caused a fast increase of [Ca2+]i from approx. 50 nM to above 500 nM. In contrast, the subsequent substitution of CaCl2 by EGTA decreased [Ca2+]i again below 100 nM within 0.5 h. Furthermore, the application of ionomycin could initiate a change in [Ca2+]i according to the Ca2+ gradient established between the extracellular medium and cytoplasm. In spores sown on a Ca(2+) -free medium, [Ca2+]i, analysed in a buffer containing EGTA, was found to be around 50 nM during the first days of cultivation, independent of the irradiation protocol. However, if spores were grown in darkness on a Ca(2+) -containing medium and analysed in EGTA, [Ca2+]i was significantly higher (> or = 500 nM). In red-light-irradiated spores, [Ca2+]i was found to decrease with increasing time after irradiation, and was determined to be less than 100 nM when analysis was done 44 h after germination was initiated by the light treatment.

NASA Discipline Plant Biology↗

Pulse Profiles, Accretion Column and a flare in Gx 1+4 During a Faint State

The Rossi X-ray Timing Explorer (RXTE) spacecraft observed the X-ray pulsar GX 1+4 for a period of 34 hours on July 19/20 1996. The source faded from an intensity of approx. 20 mcrab to a minimum of less than or equal to 0.7 mcrab and then partially recovered towards the end of the observation. This extended minimum lasted approx. 40,000 seconds. Phase folded light curves at a barycentric rotation period of 124.36568 +/- 0.00020 seconds show that near the center of the extended minimum the source stopped pulsing in the traditional sense but retained a weak dip feature at the rotation period. Away from the extended minimum the dips are progressively narrower at higher energies and may be interpreted as obscurations or eclipses of the hot spot by the accretion column. The pulse profile changed from leading-edge bright before the extended minimum to trailing-edge bright after it. Data from the Burst and Transz'ent Source Experiment (BATSE) show that a torque reversal occurred less than 10 days after our observation. Our data indicate that the observed rotation departs from a constant period with a P/P value off approx. -5% per year at a 4.5(sigma) significance. We infer that we may have serendipitously obtained data. with high sensitivity and temporal resolution about the time of an accretion disk spin reversal. We also observed a rapid flare which had some precursor activity close to the center of the extended minimum.

Giles, A. B.↗

Understanding spectral dependance of laser-induced damage precursors in dielectric materials (Abbreviated report_23-ERD-006)

High peak and average power laser systems are typically limited by the handling fluence of the optical components. In particular, the multilayer dielectric coatings are known to be much lower operational fluence than the more ideal bulk materials. In this project we proposed and succeeded in probing different established classes of damage prone precursors at different wavelengths to understand their fundamental laser damage response as a function of wavelength. This study helped to shed light on the fundamental physics of the non-linear precursors that govern laser damage phenomena for ns-regime pulsed laser damage. In this study, we utilized the onsite coating capabilities (VPL, IBS coating lab) to purposefully generate laser damage-prone precursors in hafnia-based coatings (both single and multi-layer coatings). Specifically, we engineered coatings with craze lines initiated by nodules, generated coatings with our xenon-based coating process to suppress nanobubble formation and generated hafnia coatings under controlled oxygen flow conditions to study hafnia sub-oxides and oxygen flow dependance. In these studies we found that craze lines are rife with precursors that are sensitive to ultra-violet light but not to infrared light; we found that the removal of nanobubbles helps with all wavelengths tested, but is most impactful for ultra-violet light; we also found that ultra-violet laser damage performance of hafnia is closely matched to oxygen flow rate, while the infrared performance may be slightly better at lower flow rates. During this LDRD we also successfully stood up a new laser damage testing capability, namely a wavelength agile damage test station to study the spectral response of known laser-induced damage precursors. This is a unique and important capability for Lawrence Livermore National Lab, allowing us to understand the spectral response of materials under high intensity irradiation and damage. This is a vital tool to understand non-linear optical response at wavelengths that we have previously been unable to test at.

36 MATERIALS SCIENCE↗

Measurement of the liquid argon scintillation pulse shape using differentiable simulation in the coherent CAPTAIN-Mills experiment

The coherent CAPTAIN-Mills (CCM) experiment is a liquid argon (LAr) light collection detector searching for MeV-scale neutrino and beyond Standard Model physics signatures. Two hundred eight-inch photomultiplier tubes instrument the seven-ton fiducial volume with 50% photocathode coverage to detect light produced by charged particles. CCM’s light-based approach reduces requirements of LAr purity, compared to other detection technologies, such that sub-MeV particles can be reliably detected without additional LAr filtration and with 𝒪⁡(1) parts per million of common contaminants. We present a measurement of LAr light production and propagation parameters, with uncertainties, obtained from a sample of MeV-scale electromagnetic events. The optimization of this high-dimensional parameter space was facilitated by a differentiable optical photon Monte Carlo simulation and detailed photomultiplier tube response characterization. This result accurately predicts the timing and spatial distribution of light due to scintillation and Cherenkov emission in the detector. This is the first description of photon propagation in LAr to include several effects, including anomalous dispersion of the index of refraction near the ultraviolet resonance, Mie scattering from impurities, and Cherenkov light production.

Cherenkov detectors↗

A phenomenological rate of injection model for predicting fuel injection with application to mixture formation in light-duty diesel engines

Fuel injection rate laws are one of the most important pieces of information needed when modeling engine combustion with computational fluid dynamics. In this study, a simple phenomenological model of a common-rail injector was developed and calibrated for the Bosch CRI2.2 platform. The model requires three tunable parameter fits, making it relatively easy to calibrate and suitable for injector modeling when high-fidelity information about the internal injector’s geometry and electrical circuit details are not available. Each injection pulse is modeled as a sequence of up to four stages: an injection needle mechanical opening transient, a full-lift viscous flow inertial transient, a Bernoulli steady-state stage, and a needle descent transient. Parameters for each stage are obtained as polynomial fits from measured injection rate properties. The model enforces total injected mass, and the intermediate stages are only introduced if the injection pulse duration is long enough. Experimental rates of injection from two separate campaigns on the same injector were used to calibrate the model. The model was first validated against measured injection rate laws featuring pilot injections, short partially premixed combustion pulses, and conventional diesel combustion injection strategies. Then, it was employed as an input to engine computational fluid dynamics simulations, which were run to simulate experiments of mixture formation in an optically accessible light-duty diesel engine. It was found that, though simple, this model is capable of predicting both pilot and main injection pulse mass flow rates well: the simulations yielded accurate predictions of in-cylinder equivalence ratio distributions from injection strategies for both partially premixed combustion and pilot injections. Also, once calibrated, the model produced appropriate results for a wide range of injected mass and rail pressure values. Finally, it was observed that usage of such a relatively simple model can be a good choice when high-fidelity injection rate input and highly detailed information of the injector’s geometry and operation are not available, particularly as noticeable discrepancies can be present also among different experimental campaigns on similar hardware.

42 ENGINEERING↗

Filament-induced breakdown spectroscopy of solids through highly scattering media

Ultrafast laser pulse filamentation in the air can be used for remote sensing by exciting a characteristic optical emission, which is usually referred to as filamentation-induced breakdown spectroscopy. In environments that impede light propagation, such as fog, haze, or clouds, scattering makes it challenging to propagate laser beams and retrieve generated optical signatures. We demonstrate the effectiveness of laser filamentation for simultaneously clearing the path for intense femtosecond pulse propagation in a highly scattering medium, generation of luminous plasma on a solid target, and counter-propagation of a characteristic spectroscopic signal over a cleared channel along the filament path. In a dense cloud, the counter-propagating signal predominantly transits the cleared on-axis path but is highly affected by the negative thermal lensing of a Gaussian beam. Furthermore, these insights enhance our understanding of laser filamentation in atmospheric sensing and could substantially improve remote detection capabilities in poor visibility conditions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Uranium Single Particle Analysis for Simultaneous Fluorine and Uranium Isotopic Determinations via Laser-Induced Breakdown Spectroscopy/Laser Ablation–Multicollector–Inductively Coupled Plasma–Mass Spectrometry

Uranyl fluoride (UO 2 F 2 ) particles (<20 μm) were subjected to first-of-its-kind analysis via simultaneous laser-induced breakdown spectroscopy (LIBS) and laser ablation multi-collector inductively coupled plasma–mass spectrometry (LA–MC–ICP–MS). Briefly, a nanosecond pulsed high-energy laser was focused onto the sample (particle) surface. In a single laser pulse, the UO 2 F 2 particle was excited/ionized within the microplasma volume, and the emission of light was collected via fiber optics such that emission spectroscopy could be employed for the detection of uranium (U) and fluorine (F). The ablated particle was simultaneously transported into the MC–ICP–MS for high precision isotopic (i.e., 234 U, 235 U, and 238 U) analysis. This method, LIBS/LA–MC–ICP–MS was optimized and employed to rapidly measure 80+ UO 2 F 2 particles, which were subjected to different calcination processes, which results in varying degrees of F loss from the individual particles. In measuring the particles, the average F/U ratios for the populations treated at 100 and 500 °C were 2.78 ± 1.28 and 1.01 ± 0.50, respectively, confirming loss of F through the calcination process. The average 235 U/ 238 U on the particle populations for the 100 and 500 °C were 0.007262 (22) and 0.007231 (23), which was determined to be <0.2% from the expected value. The 234 U/ 238 U ratios on the same particles were 0.000053 (11) and 0.000050 (10) for the 100 and 500 °C, respectively, <10% from the expected value. Notably, each population was analyzed in under 5 min, demonstrating the truly rapid analysis technique presented here in this paper.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Holes in Optical Lightning Flashes: Identifying Poorly Transmissive Clouds in Lightning Imager Data

Space-based optical lightning sensors including the lightning imaging sensor (LIS) and geostationary lightning mapper (GLM) are pixelated imagers that detect lightning as transient increases in cloud top illumination. Detection requires optical emissions to escape the cloud top to space with sufficient energy to trigger a pixel on the imaging array. Through scattering and absorption, certain clouds are able to block most light from reaching the instrument, causing a reduction in detection efficiency (DE) and possibly location accuracy (LA). Radiant lightning emissions that illuminate large cloud top areas are used to examine scenarios where clouds block light from reaching orbit. In some cases, these anomalies in the spatial radiance distribution from the lightning pulse lead to “holes” in the optical lightning flash where certain pixels fail to trigger. Such holes are identified algorithmically in the Tropical Rainfall Measuring Mission satellite LIS record and the microphysical properties of the coincident storm region are queried. We find that holes primarily occur in tall (IR T b < 235 K) convection (87%) and overhanging anvil clouds (10%). The remaining 3% of holes occur in moderate-to-weak convection or in clear air breaks between stormclouds. We further demonstrate how an algorithm that assesses the spatial radiance patterns from energetic lightning pulses might be used to construct an optical transmission gridded stoplight product for GLM that could help operators identify clouds with a potentially reduced DE and LA.

54 ENVIRONMENTAL SCIENCES↗

Design of the Multi-Ion Injector Linac for the JLAB EIC (JLEIC)

An Electron Ion Collider (EIC) is the highest priority for future U.S. accelerator-based nuclear physics facility following the completion of the Facility for Rare Isotope Beams (FRIB). Two laboratories are competing to host the future EIC: Brookhaven National Lab. (BNL) and Jefferson Lab. (JLab). The baseline design of JLab's Electron Ion Collider (JLEIC) ion complex comprises a pulsed superconducting (SC) linac injector capable of accelerating all ions from protons to lead, where proton and light ion beams can be polarized. After reviewing the design requirements for the injector linac, important design choices such as the room-temperature (RT) section design, the transition energy between the RT and SC sections and the stripping energy for heavy ions will be discussed. The design of the different linac sections will be presented as well as the results of end-to-end beam dynamics simulations for polarized deuterons and unpolarized lead ions.

Mustapha, B.↗

Octave-spanning mid-infrared femtosecond OPA in a ZnGeP 2 pumped by a 2.4 μm Cr:ZnSe chirped-pulse amplifier

We report on the highly efficient, octave-spanning mid-infrared (mid-IR) optical parametric amplification (OPA) in a ZnGeP 2 (ZGP) crystal, pumped by a 1 kHz, 2.4 μm, 250 fs Cr:ZnSe chirped-pulse amplifier. The full spectral coverage of 3−10 μm with the amplified signal and idler beams is demonstrated. The signal beam in the range of ∼3 − 5 μm is produced by either white light generation (WLG) in YAG or optical parametric generation (OPG) in ZGP using the common 2.4 μm pump laser. We demonstrate the pump to signal and idler combined conversion efficiency of 23% and the pulse energy of up to 130 μJ with ∼2 μJ OPG seeding, while we obtain the efficiency of 10% and the pulse energy of 55 μJ with ∼0.2 μJ WLG seeding. The OPA output energy is limited by the available pump pulse energy (0.55 mJ at ZGP crystal) and therefore further energy scaling is feasible with multi-stage OPA and higher pump pulse energy. The autocorrelation measurements based on random quasi-phase matching show that the signal pulse durations are ∼318 fs and ∼330 fs with WLG and OPG seeding, respectively. In addition, we show the spectrally filtered 30 μJ OPA output at 4.15 μm suitable for seeding a Fe:ZnSe amplifier. Our ultrabroadband femtosecond mid-IR source is attractive for various applications, such as strong-field interactions, dielectric laser electron acceleration, molecular spectroscopy, and medical surgery.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

HIGHER EFFICIENCY FISSION COUNTER FOR NEUTRON DETECTION

Fission chambers containing 235U have been used for detection of neutrons for many decades. In these chambers 235U is electroplated on a metal which is one plate of an ionization chamber. Since the range of fission products from induced fission in the chamber is extremely short, these deposits from electroplating are so thin that the amount of 235U results in low neutron detection efficiency and the chamber needs high internal 235U surface area to increase efficiency. A typical ~8 in. long, ~2 in. diameter fission counter only contains < 2 g of 235U total, resulting in very low detection efficiency per incident neutron impinging on the outer surface of the detector. However, because of their large electronic pulses from fission products compared to gamma rays it is very easy to discriminate against gamma rays impinging on the detector. These types of chambers are produced commercially and are used worldwide in nuclear research and nuclear power reactors. ORNL has made a higher efficiency fission ionization chamber by using many thin concentric annuli to increase the area. A higher efficiency fission counter would be useful and can be made by incorporating 235U into a glass or ceramic scintillator. For nearly 100 years the green color in antique glass was produced by incorporation of depleted uranium (up to 20 wt. %) into a glass. The concept for this scintillation-optical-based fission detector is to dope a scintillator (either ceramic or glass) with 235U. Glass scintillators are commercially available doped with as much as 8 wt. % 6Li for neutron detection. In the 235U doped scintillator the fission product pulses would be double the size of those in an ion chamber since all fission products produce light in the scintillator whereas in the ionization chamber half do not go into the ionizing gas volume. These higher efficiency fission chambers would be very useful for a wide variety of research, nuclear research, and nuclear power reactor applications. Because of their smaller size and weight, they should be useful for space application such as monitoring of space nuclear power reactors. This report reviews existing fission chamber technology and suggests the development of these small high-efficiency fission chambers. Other fission isotopes could be used for other research applications.

Mihalczo, John [ORNL] (ORCID:0000000254292681)↗

Towards a Counting Point Detector for Nanosecond Coherent X-ray Science

We present the technical realization of a high-speed hard X-ray single-photon counting-detection scheme based on a commercial avalanche silicon photodiode and high-speed oscilloscope. The development is motivated by the need to perform pulse-resolved photon-correlation and pump-probe studies at synchrotron sources with densely packed pulse patterns that result in high repetition rate pulses on the order of hundreds of MHz. Commissioning experiments are performed at the 1C PAL-KRISS beamline at PLS-II of South Korea operating at a burst mode maximum repetition rate of 500 MHz. In such a high count-rate measurement, detector dead-time can lead to a distortion of counting statistics. We are able to model the counting behavior of our detector under these conditions with a detector dead-time comparable to time between X-ray pulses, implying that nanosecond X-ray photon correlation spectroscopy should be possible at diffraction-limited light sources.

36 MATERIALS SCIENCE↗