The response of Galileo aft cover components to laser radiation

The aft region of the Galileo probe will be subjected to severe heat transfer rates dominated by the radiation contributions. To assess the response of several vehicle aft region components to thermal radiation, tests employing a 10 KW CO2 laser were conducted. The experiments evaluated the annulus/aft cover interface, the umbilical feedthrough assembly and the mortar cover seal assembly. Experimental evidence of the response of the phenolic nylon heatshield and quantitative measures of its effect on gap geometries of several vehicle components were acquired. In addition, qualitative measures of the survivability of the irradiated components were obtained.

Metzger, J. W.↗

Ultrafast electron kinetics in short pulse laser-driven dense hydrogen

Dense cryogenic hydrogen is heated by intense femtosecond infrared laser pulses at intensities of ${10}^{15}-{10}^{16}\;$ W cm–2. Three-dimensional particle-in-cell (PIC) simulations predict that this heating is limited to the skin depth, causing an inhomogeneously heated outer shell with a cold core and two prominent temperatures of about $25$ and $40\;\mathrm{eV}$ for simulated delay times up to $+70\;\mathrm{fs}$ after the laser pulse maximum. Experimentally, the time-integrated emitted bremsstrahlung in the spectral range of 8–18 nm was corrected for the wavelength-dependent instrument efficiency. The resulting spectrum cannot be fit with a single temperature bremsstrahlung model, and the best fit is obtained using two temperatures of about 13 and $30\;$eV. The lower temperatures in the experiment can be explained by missing energy-loss channels in the simulations, as well as the inclusion of hot, non-Maxwellian electrons in the temperature calculation. In conclusion, we resolved the time-scale for laser-heating of hydrogen, and PIC results for laser–matter interaction were successfully tested against the experiment data.

42 ENGINEERING↗

Advanced Modeling of Micromirror Devices

The flexure-beam micromirror device (FBMD) is a phase only piston style spatial light modulator demonstrating properties which can be used for phase adaptive corrective optics. This paper presents a complete study of a square FBMD, from advanced model development through final device testing and model verification. The model relates the electrical and mechanical properties of the device by equating the electrostatic force of a parallel-plate capacitor with the counter-acting spring force of the device's support flexures. The capacitor solution is derived via the Schwartz-Christoffel transformation such that the final solution accounts for non-ideal electric fields. The complete model describes the behavior of any piston-style device, given its design geometry and material properties. It includes operational parameters such as drive frequency and temperature, as well as fringing effects, mirror surface deformations, and cross-talk from neighboring devices. The steps taken to develop this model can be applied to other micromirrors, such as the cantilever and torsion-beam designs, to produce an advanced model for any given device. The micromirror devices studied in this paper were commercially fabricated in a surface micromachining process. A microscope-based laser interferometer is used to test the device in which a beam reflected from the device modulates a fixed reference beam. The mirror displacement is determined from the relative phase which generates a continuous set of data for each selected position on the mirror surface. Plots of this data describe the localized deflection as a function of drive voltage.

Michalicek, M. Adrian↗

Development of a wideband pulse quaternary modulation system

Laboratory data verifying the pulse quaternary modulation (PQM) theoretical predictions is presented. The first laboratory PQM laser communication system was successfully fabricated, integrated, tested and demonstrated. System bit error rate tests were performed and, in general, indicated approximately a 2 db degradation from the theoretically predicted results. These tests indicated that no gross errors were made in the initial theoretical analysis of PQM. The relative ease with which the entire PQM laboratory system was integrated and tested indicates that PQM is a viable candidate modulation scheme for an operational 400 Mbps baseband laser communication system.

Federhofer, J. A.↗

Deposition of tantalum carbide coatings on graphite by laser interactions

Graphite surfaces can be hardened and protected from erosion by hydrogen at high temperatures by refractory metal carbide coatings, which are usually prepared by chemical vapor deposition (CVD) or chemical vapor reaction (CVR) methods. These techniques rely on heating the substrate to a temperature where a volatile metal halide decomposes and reacts with either a hydrocarbon gas or with carbon from the substrate. For CVR techniques, deposition temperatures must be in excess of 2000 C in order to achieve favorable deposition kinetics. In an effort to lower the bulk substrate deposition temperature, the use of laser interactions with both the substrate and the metal halide deposition gas has been employed. Initial testing involved the use of a CO2 laser to heat the surface of a graphite substrate and a KrF excimer laser to accomplish a photodecomposition of TaCl5 gas near the substrate. The results of preliminary experiments using these techniques are described.

Veligdan, James↗

Structural Benchmark Creep Testing for Microcast MarM-247 Advanced Stirling Convertor E2 Heater Head Test Article SN18

This report provides test methodology details and qualitative results for the first structural benchmark creep test of an Advanced Stirling Convertor (ASC) heater head of ASC-E2 design heritage. The test article was recovered from a flight-like Microcast MarM-247 heater head specimen previously used in helium permeability testing. The test article was utilized for benchmark creep test rig preparation, wall thickness and diametral laser scan hardware metrological developments, and induction heater custom coil experiments. In addition, a benchmark creep test was performed, terminated after one week when through-thickness cracks propagated at thermocouple weld locations. Following this, it was used to develop a unique temperature measurement methodology using contact thermocouples, thereby enabling future benchmark testing to be performed without the use of conventional welded thermocouples, proven problematic for the alloy. This report includes an overview of heater head structural benchmark creep testing, the origin of this particular test article, test configuration developments accomplished using the test article, creep predictions for its benchmark creep test, qualitative structural benchmark creep test results, and a short summary.

life (durability)↗

Field investigation of techniques for remote laser sensing of oceanographic parameters

A laser fluorosensor, previously studied in the laboratory, was deployed at a pier in lower Chesapeake Bay for field testing. A Q-switched Nd:YAG laser doubled to 532 nm in conjunction with a gated optical multichannel analyzer (OMA) allow spectra with high signal-to-noise ratios to be recorded in full daylight at a distance of 20 m. As a test of the system a study was conducted of the spatial and temporal variations of the phytopigments phycoerythrin and chlorophyll. The phycoerythrin feature was resolved into two components, one attributable to cyanophytes and the other to cryptophytes. A comparison was also made with spectra obtained by the NASA airborne oceanographic lidar (AOL).

Houghton, W. M.↗

SU-E-T-484: A New Method of Aligning Patient Setup Lasers in Radiation Therapy

Purpose: To develop a new method to align the patient setup lasers in radiation therapy and examine its validity and effectiveness. Methods: The new laser alignment method was realized by a device composed of both a metallic base plate and few acrylic transparent plates with a cross hair line on each of them. The holders of radiochromic films were prepared in the device to find a radiation isocenter. The right laser positions could be found optically by matching the shadows of all the cross hairs in the gantry head and the device. The repeatability and reproducibility (R and R) of laser alignments and the dependency of the alignment on the position error of the light source were evaluated by comparing the standard deviations and the means of the measured laser positions. After aligning the lasers optically, a radiation isocenter was found by a collimator spoke shot and the gantry spoke shot, and then the lasers were parallely translated to the isocenter. Results: In the R and R test, the standard deviation was 1.14 mm for the new method whereas it was 1.49 mm or 2.76 mm for the conventional method with either high- or low-precision levels. In the test of the dependency on the position error of the light source, the mean laser position was shifted by 5.3 mm corresponding to the shift of the light source, 4.8 mm for the new method, but for the conventional method the laser position was shifted more than 7 times than that. The positional shift could be corrected by a parallel translation to the isocenter in the new method. Conclusion: A new laser alignment method was devised for radiation therapy and tested successfully. The method enabled us to align the lasers easily and accurately without repetition, and all lasers could be finally aligned to the radiation isocenter.

60 APPLIED LIFE SCIENCES↗

Evaluation of Laser Stabilization and Imaging Systems for LCLS-II (Final Paper)

By combining the top performing commercial laser beam stabilization system with the most ideal optical imaging configuration, the beamline for the Linear Accelerator Coherent Light Source II (LCLS-II) will deliver the highest quality and most stable beam to the cathode. To determine the optimal combination, LCLS-II beamline conditions were replicated and the systems tested with a He-Ne laser. The Guidestar-II and MRC active laser beam stabilization systems were evaluated for their ideal positioning and stability. Both a two and four lens optical imaging configuration was then evaluated for beam imaging quality, magnification properties, and natural stability. In their best performances when tested over fifteen hours, Guidestar-II kept the beam stable over approximately 70-110um while the MRC system kept it stable over approximately 90-100um. During short periods of time, Guidestar-II kept the beam stable between 10-20um, but was more susceptible to drift over time, while the MRC system maintained the beam between 30-50um with less overall drift. The best optical imaging configuration proved to be a four lens system that images to the iris located in the cathode room and from there, imaged to the cathode. The magnification from the iris to the cathode was 2:1, within an acceptable tolerance to the expected 2.1:1 magnification. The two lens configuration was slightly more stable in small periods of time (less than 10 minutes) without the assistance of a stability system, approximately 55um compared to approximately 70um, but the four lens configurations beam image had a significantly flatter intensity distribution compared to the two lens configuration which had a Gaussian distribution. A final test still needs to be run with both stability systems running at the same time through the four lens system. With this data, the optimal laser beam stabilization system can be determined for the beamline of LCLS-II.

43 PARTICLE ACCELERATORS↗

Evaluation of Laser Stabilization and Imaging Systems for LCLS-II

By combining the top performing commercial laser beam stabilization system with the most ideal optical imaging configuration, the beamline for the Linear Accelerator Coherent Light Source II (LCLS-II) will deliver the highest quality and most stable beam to the cathode. To determine the optimal combination, LCLS-II beamline conditions were replicated and the systems tested with a He-Ne laser. The Guidestar-II and MRC active laser beam stabilization systems were evaluated for their ideal positioning and stability. Both a two and four lens optical imaging configuration was then evaluated for beam imaging quality, magnification properties, and natural stability. In their best performances when tested over fifteen hours, Guidestar-II kept the beam stable over ~ 70-110um while the MRC system kept it stable over ~ 90- 100um. During short periods of time, Guidestar-II kept the beam stable between 10-20um, but was more susceptible to drift over time, while the MRC system maintained the beam between 30-50um with less overall drift. The best optical imaging configuration proved to be a four lens system that images to the iris located in the cathode room and from there, imaged to the cathode. The magnification from the iris to the cathode was 2:1, within an acceptable tolerance to the expected 2.1:1 magnification. The two lens configuration was slightly more stable in small periods of time (<10 minutes) without the assistance of a stability system, ~ 55um compared to ~ 70um, but the four lens configuration’s beam image had a significantly flatter intensity distribution compared to the two lens configuration which had a Gaussian distribution. A final test still needs to be run with both stability systems running at the same time through the four lens system. With this data, the optimal laser beam stabilization system can be determined for the beamline of LCLS-II.

43 PARTICLE ACCELERATORS↗

Geometric scaling of laser-driven proton focusing from hemispherical foils

We systematically characterize the focusing behavior of laser-driven proton beams from hemispherical targets of various diameters using mesh radiography. The proton focal location is inferred to be near the geometrical center for the smallest tested hemisphere (Ψ = 𝐷 hemi /𝐷 Laser = 6.1). However, larger hemispheres (Ψ = 14.6) degrade the focusing behavior and behave more like flat foils with focal location significantly inside the hemisphere. We also infer a tight virtual focus of 9 ± 3 𝜇⁢m through a mesh transition analysis.

Griff-McMahon, J. [Princeton Univ., NJ (United Sta↗

Advances in laser technology for the atmospheric sciences; Proceedings of the Seminar, San Diego, Calif., August 25, 26, 1977

These papers deal with recent research, developments, and applications in laser and electrooptics technology, particularly with regard to atmospheric effects in imaging and propagation, laser instrumentation and measurements, and particle measurement. Specific topics include advanced imaging techniques, image resolution through atmospheric turbulence over the ocean, an efficient method for calculating transmittance profiles, a comparison of a corner-cube reflector and a plane mirror in folded-path and direct transmission through atmospheric turbulence, line-spread instrumentation for propagation measurements, scaling laws for thermal fluctuations in the layer adjacent to ocean waves, particle sizing by laser photography, and an optical Fourier transform analysis of satellite cloud imagery. Other papers discuss a subnanosecond photomultiplier tube for laser application, holography of solid propellant combustion, diagnostics of turbulence by holography, a camera for in situ photography of cloud particles from a hail research aircraft, and field testing of a long-path laser transmissometer designed for atmospheric visibility measurements.

Trolinger, J. D.↗

Distributed fiber sensing systems for 3D combustion temperature field monitoring in coal-fired boilers using optically generated acoustic waves (Final Report)

In this project, we have developed and tested three kinds of fiber optic sensing systems for real time monitoring of temperature variations within an industrial scale boiler furnace. The fiber optic sensing systems target spatial and temporal distributions of high temperature profiles in a boiler furnace in fossil power plants. The reconstructed temperature profile will provide critical input for the control mechanisms to optimize the combustion process. This temperature profile will address the essential problem for fossil power plants in achieving higher efficiency and fewer pollutant emissions. Acoustic pyrometer systems have been used to reconstruct temperature field of power plant boilers based on measuring TOF (times-of-flight) of sound waves along some straight paths in a 2D cross-section of the boiler. In this project, optically generated acoustic signals from a fiber optic sensing system have replaced the acoustic signals generated from an electrical transducer. A 3D reconstruction algorithm replaced the previous 2D model. In this project, three kinds of fiber optic sensing systems have been developed and tested. They are fiber optic sensing system I, fiber optic sensing system II (Distributed Sensing System I) and fiber optic sensing system III (Distributed Sensing System II). For fiber optic sensing system I, the fiber optic ultrasound generator acts as a signal generator. A microphone, hydrophone or other electronic devices serve as a signal receiver. In this system, there are one generator and one receiver. Distance test, water temperature test, air temperature test, air temperature reconstruction, and GE ISBF pilot test were performed by Fiber optic sensing system I. The fiber optic sensing system I successfully detected temperature in all these tests. We got 2D temperature reconstruction results by using the fiber optic sensing system I and it matched the reference data. The fiber optic sensing system I successfully survived in GE ISBF boiler environment (480 °F). For fiber optic sensing system II (Distributed Sensing System I), it is an all optical ultrasound system. The fiber optic ultrasound generator acts as a signal generator. Fiber Bragg Grating (FBG) and Fabry-Perot (FP) sensor act as a signal receiver. In this system, there is one generator and one receiver. Aluminum plate temperature test, furnace high temperature test, and GE ISBF pilot test were performed by the fiber optic sensing system II. Fiber optic sensing system II successfully detected the temperature in all these tests. The fiber optic sensing system II successfully survived at up to 700 °C furnace environment and 320 °C GE ISBF boiler environment. For fiber optic sensing system III (Distributed Sensing System II), it is also an all optical ultrasound system. The fiber optic ultrasound generator acts as a signal generator. Multiple FP fiber sensors act as signal receivers. In this system, there is one generator and three receivers. Three GE ISBF pilot tests were performed by fiber optic sensing system III. The fiber optic sensing system III survived in the cold flow tests in GE’s ISBF pilot test facility. However, we didn’t get high temperature data by using this system since the nanosecond laser issues. During the period of the project, test trials, data simulation and algorithm optimization was performed successfully. For real time temperature field construction, the sampling rate must be fast enough to capture the field variations. The technology of Code-division multiple access (CDMA) is well studied which could allow parallel multiplexing, even if signals overlap in time or frequencies. Moreover, it has been known that extending the length of signal significantly improves SNR. For acoustic signals, these multiplexing techniques have also been widely used, mainly for sonar and acoustic communications. The CDMA modulation technique has been proposed and studied to guarantee high network throughput, low channel access delay and low energy consumption. We have studied the temperature field reconstruction using Gaussian Radial Basis Functions (GRBF)-based approximation approach. Reconstruction of 3D temperature field using Neural Networks with measured TOF and known propagation paths is feasible. 2D and 3D temperature field reconstruction simulation results are achieved. The milestone status is shown in Table 1. We finished milestone 1-8 and milestone 10. For milestone 9, we did three pilot tests by using the fiber optic sensing system III (Distributed Sensing System II) at GE Power. However, due to the failure of the ns laser, we did not get the temperature results. We conducted some additional tasks that were not originally proposed: 1) We fabricated a fiber optic sensing system I and did a pilot test based on this system. 2) In the proposal, we proposed two pilot tests at GE Power. In reality, we finished at least seven pilot tests at GE Power. GE Power has made a lot of efforts for supporting the pilot tests. 3) We got a simulation results based on CDMA. In summary, most of the tasks have been accomplished. The outcome of this project removed a few barriers that hinder the achievement of the final product of the distributed sensing systems. With the successful accomplishment of this project, a prototype of the fiber optic sensing system can be fabricated to attract more interests from companies and other funding agencies.

47 OTHER INSTRUMENTATION↗

Laser Ablation Cleaning of Self-Reacting Friction Stir Weld Seam Surfaces: A Preliminary Evaluation

Anodized aluminum panels were cleaned by three lasers at three separate sites with a view to determining whether more economical laser cleaning might supplant current manual cleaning methods for preparation of surfaces to be welded by the self-reacting friction stir process. Uncleaned panels yielded welds exhibiting residual oxide defect (ROD) and failing at very low stresses along the trace of the weld seam. Manually cleaned panels yielded welds without ROD; these welds failed at nominal stress levels along an angled fracture surface not following the weld seam trace. Laser cleaned panels yielded welds failing at intermediate stress levels. The inadequacy of the laser cleaning processes leaves questions: Was the anodized aluminum test too stringent to represent actual cleaning requirements? Were the wrong laser cleaning techniques/parameters used for the study? Is the laser cleaning mechanism inadequate for effective preweld surface cleaning?

Nunes, A. C., Jr.↗

Cirrus Parameter Retrieval by Combined Analysis of Spectral Thermal Infrared and Lidar Sensing from Aircraft and Space

The distribution, radiative and microphysical parameters of cirrus clouds are an important factor for cloud effects on the global radiation balance and climate. Multispectral thermal infrared observation are the most significant method used to remote sense cirrus parameter from current and planned passive satellite observations. Passive sensing alone has the limitation that both the cloud radiative temperature, or height, and the spectral emissivity must be derived in the analysis. Factors such as multiple cloud laying, which is very common, are known to introduce ambiguities in results. The addition of lidar cloud height structure measurements significantly improves retrievals. Such active/passive observations have been applied from the NASA ER-2 high altitude remote sensing aircraft since 1983. Applications include the study of the effective effective particle size of cirrus and application toward remote sensing of the ice/water content of cirrus clouds in addition to radiative parameters. Limitations, accuracy and examples of retrievals are presented. In 1997 a space shuttle hitch hiker experiment was flown which included a new technology Infrared Spectral Imaging Radiometer and a laser altimeter for direct cloud height measurements. A 30 orbit data set to test global application of combined spectral infrared and laser height measurements were obtained. Initial results for cirrus analysis from the shuttle experiment will also be presented.

Spinhirne, James D.↗

Advanced Manufactured Strain Sensors for Extreme Environments

Experimentation at irradiation test facilities are essential for reducing the innovation time of developmental fuels, fuel cladding, and structural materials employed in next-generation nuclear reactors. However, due to the harsh conditions generated in such reactors and limited instrumentation space, the evaluation of a material’s mechanical properties is often limited to characterization after the materials have been removed from reactor conditions, or post-irradiation examination. These experiments are costly, time-consuming, and fail to capture the critical time-evolving phenomena that occur during the irradiation experiments. Advanced manufactured digital image correlation patterns and strain sensor devices serve as two promising technologies that can be deployed in the confined and challenging orientations of these irradiation experiments while also providing key insight on salient materials phenomena (i.e., mechanical properties). To guide the development of the printed strain sensors prior to their deployment in critical experiments, the adhesion strength between the substrate and printed film interface is measured via tensile testing and a non-contact laser-induced spallation technique. The establishment of these process control steps helped guide the successful fabrication and testing of direct-write strain sensing devices discussed in this work. The fabrication process controls are necessary for enabling the sustained operation of these strain sensing device through experimentation and minimize the potential for premature failure.

36 - MATERIALS SCIENCE↗

Non-intrusive Shock Measurements Using Laser Doppler Vibrometers

Stud mount accelerometers are widely used by the aerospace industry to measure shock environments during hardware qualification. The commonly used contact-based sensors, however, interfere with the shock waves and distort the acquired signature, which is a concern not actively discussed in the community. To alleviate these interference issues, engineers at the Jet Propulsion Laboratory are investigating the use of non-intrusive sensors, specifically Laser Doppler Vibrometers, as alternatives to the stud mounted accelerometers. This paper will describe shock simulation tests completed at the Jet Propulsion Laboratory, compare the measurements from stud mounted accelerometers and Laser Doppler Vibrometers, and discuss the advantages and disadvantages of introducing Laser Doppler Vibrometers as alternative sensors for measuring shock environments.

shock testing↗

Polarized 3He gas circulating technologies for neutron analyzers

We outline our project to develop a circulating polarized helium-3 system for developing of large, quasi-continuously operating neutron analyzers. The project consisted of four areas: 1) Development of robust external cavity narrowed diode laser output with spectral line width < 0.17 nm and power of 2000 W. 2) Development of large glass polarizing cells using cell surface treatments to obtain long relaxation lifetimes. 3) Refinements of the circulation system with an emphasis on gas purification and materials testing. 4) Design/fabrication of a new polarizer system. 5) Preliminary testing of the new polarizer. 1. Developed Robust High-Power Narrowed Laser The optical configuration of the laser was discussed in the proposal and will be reviewed in the body of this report. The external cavity is configured to mutually lock the wavelength of five 10-bar laser stacks. All the logistical milestones were been met and critical subsystems- laser stack manifold and power divider, external laser cavity, and output telescope- were assembled and tested at low power. Each individual bar is narrowed to ~0.05 nm; when combined the laser has a cumulative spectral width of 0.17 nm across the entire beam due to variations of the bars central wavelength by +/- 0.1 nm, which is similar to that of Volume Bragg Grating narrowed laser bars. This configuration eliminates the free-running “pedestal” that occurs in other external cavity diode lasers. The full-scale laser was completed in 2016 and was used in both the older and newer helium polarizers. This laser was operated at 75% power for periods of up to 8 hours. Once installed, the spectrum became slightly broader (~.25 nm) at full power; this is likely due to very slight misalignments that occurred during handling. 2. Developed the processes to create uniform sintered sol-gel coatings. Our work on cell development comprised: 1) Production of large GE180 cells and explore different means of cell preparation, and 2) Development of apply sol-gel coatings to the interior of both borosilicate and aluminosilicate cells. We applied six sol-gel coatings. By modifying the mixture and developing procedures to drain and dry the cell, we produced visually uniform coatings on the interior of the cells. We now have perfected that process as described below in our report. We were able to accelerate the testing of cells using an ex situ method that avoids installing each cell into a polarizer. In the project’s last year, we conducted 38 external tests of 8 different cells. We also installed two sol-gel coated cells in our polarizers. We created cell with long ex situ relaxation lifetimes, one of which exceeded 40 hours. However, when installed in the polarizer the measured lifetime is 8 hours or less. 3. Demonstrated cycling of polarized gas and ex situ cell testing We are now cycling polarized gas from the polarizer to glass vessels and back. This has allowed us, for the first time, to make ex situ T1 measurements of polarizing cells without installing them into the polarizer itself. This has greatly improved our productivity in producing cells and evaluating our cell preparation processes. We continued development of the gas handling system in parallel with fabricating new polarizer. The integrated system was tested by the end of 2016. We now regularly cycle gas into and out of the polarizer. 4. Completed new polarizer infrastructure and control systems. We completed the new polarizer infrastructure in November 2016. The polarizer subsystems are 1) the frame, 2) the oil flow system, 3) the gas handling system, 4) the pressure vessel, with embedded solenoid, 5) cell mounting hardware with heat spreaders, and 6) electrical power and instrumentation. 5. Carried out initial tests of polarizer. We completed initial testing of the polarizer in April and May of 2017. These tests were carried out for periods up to 6 hours with laser power between 750 and 1300 Watts. The laser performed well and the polarization with asymptotic to 45 percent, which was below expectations. This low value resulted from a stationary thermal inversion in the cell that caused most of the laser power to be absorbed near the laser inlet window and deprived the lower portions of the cell of pumping laser light. Possible solutions to this problem include enhanced cooling of the cell near the laser entry and slight detuning of the laser. 6. Ongoing work. Our polarizer development efforts are ongoing to pursue our interest in neutron analyzers, nuclear targets, and providing helium for medical imaging. Current tests in the pipeline include: 1. Testing cooling enhancements to improve laser penetration of spectrally narrow lasers; 2. Testing of a cell with isolation valves that minimizes diffusive contact with gas handling hardware during polarization; 3. Testing of smaller hybrid cells with reduced alkali loading; 4. Producing polarized helium-3 for MRI imaging at the University of Missouri.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗