Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “interferometer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 865 records · Page 48

UV laser based stand-off acoustic sensor

A system for aerially surveying an area where a plane may have crashed in water and locating pings from the plane's black box using a laser on an aerial platform that produces laser pulses; using a launch telescope to direct the laser pulses to the water producing scattering from the laser pulses and a continuous stream of backscatter; using a receiving telescope to collect the continuous stream of backscatter; using an interferometer operatively connected to the receiving telescope to produce two outputs, wherein one output is the continuous stream of backscatter, and wherein the other output is a delayed replica of the first output; and using a data collection and analysis unit operatively connected to the interferometer to produce a measurement of the sound.

Dawson, Jay W.↗

Sensor system that uses embedded optical fibers

Sensor systems including an interferometer system are disclosed herein. In a general embodiment, the sensor system includes an optical fiber that is embedded into a sample, where the optical fiber has a reflective tip. The optical fiber is optically coupled to a sensor and a detector of the laser interferometer system. The sensor system further includes a computing device or circuit that is configured to receive electrical signals generated by the detector. The laser source is configured to emit light, which is coupled into the optical fiber. The light travels through the optical fiber until the light reaches the reflective tip, where it is reflected back through the optical fiber. The detector is impacted by the reflected light, and generates an electrical signal based upon the reflected light. The computing device generates a value that is indicative of a behavior of the sample based upon the electrical signal.

Chavez, Marcus Alexander↗

Polarimetry-Interferometry Diagnostic for Magnetic Field and Magnetic Fluctuation Measurements in High-Performance and Long-Pulse Tokamaks (Final Report)

In this grant, we executed a multi-year plan to develop an advanced Faraday-effect polarimeter-interferometer system to address both fluctuation and equilibrium diagnostic needs by providing a measurement of the plasma internal magnetic field fluctuations (including non-axisymmetric 3-D perturbations) and plasma vertical position. This diagnostic included both fast time response and low phase noise so that both the temporal dynamics of equilibrium quantities as well as high-frequency electromagnetic fluctuations could be measured simultaneously, adding new and unique measurement capabilities for the core of high-temperature plasmas. The combined polarimeter-interferometer diagnostic development was applied primarily to the tokamak magnetic configuration, focusing on high-performance regimes including H-mode, reversed shear advanced tokamak scenarios, and non-inductive current drive.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Quasi-Extended Range Optical Frequency Domain Reflectometry for Product Pipelines

Throughout the United States, large natural gas and product transmission pipelines exist. These pipelines are susceptible to failure through corrosion and cracking due to internal and external factors. As these transmission pipeline age, the likelihood of a catastrophic failure increases. The ability to the monitor corrosion and wall thickness of these pipelines is paramount to reduce risk of disastrous failure and increase reliability as well as safety. Optical frequency domain reflectometry can monitor distributed temperature and strain measurements along the natural gas and product pipelines. This measurement technique can provide valuable information of pipe structural health through hoop strain changes due to pipe wall thinning, temperature changes due to gas leaks based on Joule-Thomson effect. Since these pipelines are typically buried, the depth of the pipeline results in a potential loss in the sensing range where the fiber is not physically monitoring the hoop strain of the pipeline. A different configuration of the interferometer will allow for the distributed fiber measurement to start atop the pipeline itself. This configuration results in no loss of sensing range and maintains the sensing resolution of a typically interferometer for an optical frequency domain reflectometry measurement. The quasi-extended range distributed hoop strain measurements were demonstrated on an active transmission pipeline.

Brister, Matthew↗

Searching for cosmological stochastic backgrounds by notching out resolvable compact binary foregrounds with next-generation gravitational-wave detectors

Stochastic gravitational-wave backgrounds can be of either cosmological or astrophysical origin. The detection of an astrophysical stochastic gravitational-wave background with ground-based interferometers is expected in the near future. Perhaps even more excitingly, the detection of stochastic backgrounds of cosmological origin by future ground-based interferometers could reveal invaluable information about the early Universe. From this perspective, the astrophysical background is a {\it foreground} that can prevent the extraction of this information from the data. In this paper, we revisit a time-frequency domain notching procedure previously proposed to remove the astrophysical foreground in the context of next-generation ground-based detectors, but we consider the more realistic scenario where we remove individually detectable signals by taking into account the uncertainty in the estimation of their parameters. We find that time-frequency domain masks can still efficiently remove the astrophysical foreground and suppress it to about $5\%$ of its original level. Further removal of the foreground formed by unresolvable events (in particular, unresolvable binary neutron stars), which is about $10$ times larger than the residual foreground from realistic notching, would require detector sensitivity improvements. Therefore, the main limitation in the search for a cosmological background is the unresolvable foreground itself, and not the residual of the notching procedure.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

GQuEST Control System Resolution

GQuEST (Gravity from Quantum Entanglement of Space-Time), is a collaboration verifying a quantum gravity model by measuring holographic effects on a microscopic scale. Its interferometer apparatus filters excessive optical noise and requires a control system that can adjust the filtration to accommodate for frequency changes in the output light. We stress-test this control system by simulating filter behaviors with parameters in their outermost regimes, and we have determined a threshold that maintains precision while minimizing resource usage. These results are important for the successful operation of GQuEST's interferometer, enabling more accurate tests of quantum gravity models and thereby advancing our understanding of gravity at the quantum mechanical level.

Nguyen, David↗

Optical analog-to-digital converter

An optical analog-to-digital converter (ADC) is disclosed which converts an input optical analog signal to an output optical digital signal at a sampling rate defined by a sampling optical signal. Each bit of the digital representation is separately determined using an optical waveguide interferometer and an optical thresholding element. The interferometer uses the optical analog signal and the sampling optical signal to generate a sinusoidally-varying output signal using cross-phase-modulation (XPM) or a photocurrent generated from the optical analog signal. The sinusoidally-varying output signal is then digitized by the thresholding element, which includes a saturable absorber or at least one semiconductor optical amplifier, to form the optical digital signal which can be output either in parallel or serially.

47 OTHER INSTRUMENTATION↗

Calibration of the modulation transfer function of surface profilometers with binary pseudo-random test standards: Expanding the application range

A modulation transfer function (MTF) calibration method based on binary pseudo-random (BPR) gratings and arrays [Proc. SPIE 7077-7 (2007), Opt. Eng. 47(7), 073602-1-5 (2008)] has been proven to be an effective MTF calibration method for a number of interferometric microscopes and a scatterometer [Nucl. Instr. and Meth. A 616, 172-82 (2010]. Here we report on a significant expansion of the application range of the method. We describe the MTF calibration of a 6 inch phase shifting Fizeau interferometer. Beyond providing a direct measurement of the interferometer's MTF, tests with a BPR array surface have revealed an asymmetry in the instrument's data processing algorithm that fundamentally limits its bandwidth. Moreover, the tests have illustrated the effects of the instrument's detrending and filtering procedures on power spectral density measurements. The details of the development of a BPR test sample suitable for calibration of scanning and transmission electron microscopes are also presented. Such a test sample is realized as a multilayer structure with the layer thicknesses of two materials corresponding to BPR sequence. The investigations confirm the universal character of the method that makes it applicable to a large variety of metrology instrumentation with spatial wavelength bandwidths from a few nanometers to hundreds of millimeters.

47 OTHER INSTRUMENTATION↗

Thermal characterization of optical fibers using wavelength-sweeping interferometry

In this paper, we report a new method of thermal characterization of optical fibers using wavelength-sweeping interferometry and discuss its advantages compared to other techniques. The setup consists of two temperature-stabilized interferometers, a reference Michelson and a Mach-Zehnder, containing the fiber under test. The wavelength sweep is produced by an infrared tunable laser diode. We obtained the global phase shift coefficients of a large effective area fiber and gold-coated fiber optics with a 10{sup -7} accuracy.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Theoretical and Experimental Study of Optical Coherence Tomography (OCT) Signals Using an Analytical Transport Model

Optical coherence tomography (OCT) is a non-invasive low coherent interferometric technique that provides cross-sectional images of turbid media. OCT is based on the classical Michelson interferometer where the mirror of the reference arm is oscillating and the signal arm contains a biological sample. In this work, we analyzed theoretically the heterodyne optical signal adopting the so called extended Huygens-Fresnel principle (EHFP). We use simulated OCT images with known optical properties to test an algorithm developed by ourselves to recover the scattering coefficient and we recovered the scattering coefficient with a relative error less than 5% for noisy signals. In addition, we applied this algorithm to OCT images from phantoms of known optical properties; in this case curves were indistinguishable. A revision of the validity of the analytical model applied to our system should be done.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Explanation of Michelson's Experiment

In this paper we will prove that the Lorentz factor doesn't exist on the relative motion. In fact this factor is the result of a wrong calculation of Michelson. His mistake was approved by Lorentz and other physicists, including Einstein. Michelson in order to implement his idea with his interferometer in 1881, made the following mistake: he made the calculation according to the only principle of relativity which was known by physics--the Galileo principle, but he didn't faithfully apply this principle. In this paper, the principle of Galileo will be implemented exactly to Michelson's experiment and the result will show us that physics doesn't need the postulates of the year 1905.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Event-based Simulation Model for Quantum Optics Experiments

We present a corpuscular simulation model of optical phenomena that does not require the knowledge of the solution of a wave equation of the whole system and reproduces the results of Maxwell's theory by generating detection events one-by-one. The event-based corpuscular model gives a unified description of multiple-beam fringes of a plane parallel plate and single-photon Mach-Zehnder interferometer, Wheeler's delayed choice, photon tunneling, quantum eraser, two-beam interference, double-slit, Einstein-Podolsky-Rosen-Bohm and Hanbury Brown-Twiss experiments. We also discuss the possibility to refute our corpuscular model.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Low frequency noise distributed-feedback ytterbium fibre laser

We report a single-frequency 1-W fibre laser source emitting at 1093 nm, composed of a distributed-feedback ytterbium fibre laser and fibre-optic amplifier. The laser frequency was stabilised by side-locking to a transmission peak of a Fabry - Perot interferometer, and the residual frequency noise spectrum of the laser was measured. Our results indicate that the laser linewidth can be narrowed down below 1 kHz. (lasers)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Steady-state heating of active fibres under optical pumping

We have measured the temperature in the core of rare-earth-doped optical fibres under lasing conditions at high optical pump powers using a fibre Mach - Zehnder interferometer and probe light of wavelength far away from the absorption bands of the active ions. From the observed heating kinetics of the active medium, the heat transfer coefficient on the polymer cladding - air interface has been estimated. The temperature of the active medium is shown to depend on the thermal and optical properties of the polymer cladding. (fiber and integrated optics)

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A HYPERSPECTRAL VIEW OF THE CRAB NEBULA

We have obtained spatially resolved spectra of the Crab nebula in the spectral ranges 450-520 nm and 650-680 nm, encompassing the H{beta}, [O III] {lambda}4959, {lambda}5007, H{alpha}, [N II] {lambda}6548, {lambda}6584, and [S II] {lambda}6717, {lambda}6731 emission lines, with the imaging Fourier transform spectrometer SpIOMM at the Observatoire du Mont-Megantic's 1.6 m telescope. We first compare our data with published observations obtained either from a Fabry-Perot interferometer or from a long-slit spectrograph. Using a spectral deconvolution technique similar to the one developed by Cadez et al., we identify and resolve multiple emission lines separated by large Doppler shifts and contained within the rapidly expanding filamentary structure of the Crab. This allows us to measure important line ratios, such as [N II]/H{alpha}, [S II]/H{alpha}, and [S II] {lambda}6717 /[S II] {lambda}6731 of individual filaments, providing a new insight on the SE-NW asymmetry in the Crab. From our analysis of the spatial distribution of the electronic density and of the respective shocked versus photoionized gas components, we deduce that the skin-less NW region must have evolved faster than the rest of the nebula. Assuming a very simple expansion model for the ejecta material, our data provide us with a complete tridimensional view of the Crab.

79 ASTRONOMY AND ASTROPHYSICS↗

A 205 {mu}m [N II] MAP OF THE CARINA NEBULA

We present the results of a {approx}250 arcmin{sup 2} mapping of the 205 {mu}m [N II] fine-structure emission over the northern Carina Nebula, including the Car I and Car II H II regions. Spectra were obtained using the South Pole Imaging Fabry-Perot Interferometer (SPIFI) at the Antarctic Submillimeter Telescope and Remote Observatory (AST/RO) at the South Pole. We supplement the 205 {mu}m data with new reductions of far-IR fine-structure spectra from the Infrared Space Observatory (ISO) Long Wavelength Spectrometer (LWS) in 63 {mu}m [O I], 122 {mu}m [N II], 146 {mu}m [O I], and 158 {mu}m [C II]; the 146 {mu}m [O I] data include 90 raster positions which have not been previously published. Morphological comparisons are made with optical, radio continuum, and CO maps. The 122/205 line ratio is used to probe the density of the low-ionization gas, and the 158/205 line ratio is used to probe the fraction of C{sup +} arising from photodissociation regions (PDRs). The [O I] and [C II] lines are used to construct a PDR model of Carina. When the PDR properties are compared with other sources, Carina is found to be more akin to 30 Doradus than galactic star-forming regions such as Orion, M17, or W49; this is consistent with the view of Carina as a more evolved region, where much of the parent molecular cloud has been ionized or swept away. These data constitute the first ground-based detection of the 205 {mu}m [N II] line, and the third detection overall since those of COBE FIRAS and the Kuiper Airborne Observatory in the early 1990s.

79 ASTRONOMY AND ASTROPHYSICS↗

Implementation of one-dimensional quantum walks on spin-orbital angular momentum space of photons

Photons can carry spin angular momentum (SAM) and orbital angular momentum (OAM), which can be used to realize a qubit system and a high-dimension system, respectively. This spin-orbital system is very suitable for implementing one-dimensional discrete-time quantum random walks. We propose a simple scheme of quantum walks on the spin-orbital angular momentum space of photons, where photons walk on the infinite OAM space controlled by their SAM. By employing the recent invention of an optical device, the so-called 'q-plate', our scheme is more simple and efficient than others because there is no Mach-Zehnder interferometer in the scheme.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Interference of nonzero-rest-mass particles with time-varying energy and momentum

Solutions to the Schroedinger and Klein-Gordon equations for retroreflection of a nonzero-rest-mass particle from an accelerating mirror are determined using a retarded-phase method. The output of a Michelson interferometer, in which one mirror moves, reveals differences between the predictions of these two equations in the nonrelativistic limit when the energy and momentum of the reflected particle both vary with time.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗