Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “indicators”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 865 records · Page 48

The CanBikeCO Mini Pilot: Procedure and Preliminary Results

In fall 2020, the Colorado Energy Office, as part of the State of Colorado's "Can Do Colorado" initiative, initiated a project aimed at encouraging energy-efficient transportation during the COVID-19 pandemic. The initial mini-pilot provided e-bikes to 13 low-income households under an individual ownership model. This report assesses the impact of providing this additional mobility option on the travel behavior of participants. It also outlines the lessons learned from deploying a continuous monitoring platform to track the travel behavior. These lessons will influence the evaluation component for the full pilot, which will cover multiple geographic regions, start in summer 2021, and run for 2 years. The continuous data collection was enabled by a customized version of the open-source e-mission platform, called CanBikeCO, configured with a behavioral gamification feature. The Colorado Energy Office used this system to collect a unique data set consisting of 3 months of partially automated travel diaries, combining sensed and surveyed data and linked with demographic information, from 12 participants. The data collection process worked well overall: users generally liked the app, appreciated the game, and did not complain about battery life. The long tracking period introduced behavioral challenges in user engagement, which we plan to address using repeated patterns and automated status checks for the full pilot. The analysis results, based on the subset of trips with user-reported labels (68%), indicate that the e-bike was the dominant commute mode share (31%), in sharp contrast to the census bicycle commute mode share (<1%). E-bike trips primarily replaced single-occupancy vehicle (SOV) trips (28%), followed closely by walking (24%) and regular bike (20%). The non-motorized mode replacement corresponds to lower travel time and increased productivity enabled by the program. The emissions impact analysis of the program, computed using trip-level energy intensity factors, indicates savings of 1,367 lbs. of CO2. Although the results are strongly positive, the narrow demographic profile of study participants, their limited mobility alternatives, and nonuniform labeling indicate caution in broader interpretation. These preliminary results do suggest that such programs, supported by real-time education and support from program managers, can simultaneously meet equity and sustainability goals. The planned full pilot, addressing the data collection challenges and broadening the geographic scope, will provide additional insights into the generality of this approach.

ADVANCED PROPULSION SYSTEMS↗

Apparatus and method for providing workload distribution of threads among multiple compute units

In some examples, thermal aware optimization logic determines a characteristic (e.g., a workload or type) of a wavefront (e.g., multiple threads). For example, the characteristic indicates whether the wavefront is compute intensive, memory intensive, mixed, and/or another type of wavefront. The thermal aware optimization logic determines temperature information for one or more compute units (CUs) in one or more processing cores. The temperature information includes predictive thermal information indicating expected temperatures corresponding to the one or more CUs and historical thermal information indicating current or past thermal temperatures of at least a portion of a graphics processing unit (GPU). The logic selects the one or more compute units to process the plurality of threads based on the determined characteristic and the temperature information. The logic provides instructions to the selected subset of the plurality of CUs to execute the wavefront.

Rao, Karthik↗

Thermal measurement apparatus and methods for anisotropic thermal materials

A system for characterizing thermal properties of thermally anisotropic heterogeneous samples includes a heating element, a first temperature sensing device, a second temperature sensing device, and a computing system. The heating element is positioned at a first location within a sample and heats the sample. The first temperature sensing device outputs data indicative of temperatures of the first location to the computing device. The second temperature sensing device outputs data indicative of temperatures of the second location to the computing device. The computing device computes a thermal conductivity of the sample based upon the temperatures of the first location. The computing device further outputs an indication of a portion of the sample to which the thermal conductivity pertains based upon the second temperatures.

Reyes, Karla Rosa↗

Techno-Economic Performance of Eavor Loop 2.0

This project evaluated techno-economic performance for a sample Eavor-Loop 2.0 design for electricity production and direct-use heating. The Eavor-Loop 2.0 design investigated is a 7.5-km deep closed-loop geothermal system consisting of 12 laterals for a total of more than 90 km of downhole well and lateral length. Both a high geothermal gradient scenario of 60 degrees C/km and a low geothermal gradient scenario of 30 degrees C/km were considered. With pure water injected at 60 degrees C and 80 kg/s, reservoir simulations with the Slender-Body Theory simulator indicate average production temperatures over a 30-year lifetime of ~125 degrees C and ~210 degrees C for the low and high geothermal gradient scenario, respectively. These correspond to heat production of ~22 M Wth and ~51 M Wth, respectively. Using IPSEpro simulations, we find average power production of ~2.2 M We and ~8.6 M We, respectively, for a subcritical organic Rankine cycle power plant with air-cooled condensers. Cost estimates indicate the overall capital and levelized costs are dominated by the lateral drilling cost. Obtaining a levelized cost of electricity below $70/M Wh requires a geothermal gradient of 60 degrees C/km, a discount rate below 9%, and lateral drilling cost below $400/m. A well cost model indicates that ~$400/m for the Eavor-Loop 2.0 design investigated can be obtained for a drilling rate of penetration about 40 ft/hr (with bit life of 50 hours), and omitting casing and cement. Traditional (geothermal) well drilling has achieved these drilling rate conditions, including the Utah FORGE project where the rate of penetration has exceeded 50 ft/hr in granite. However, it is unclear if these conditions are still valid for drilling the Eavor-Loop 2.0 laterals (i.e., ~82 km of laterals at 4 to 7.5-km vertical depth with rock temperatures up to 460 degrees C), as such downhole completion has never been developed before. Competitive levelized cost of heat values ($1.2-$8.2/GJ) are calculated, even for the low geothermal gradient scenario (30 degrees C/km) and lateral drilling cost of $600/m.

advanced geothermal system↗

Selective sensor data transmission

A system controls a transmission of data. A sensor datum measured by a sensor is received. Whether to send the received sensor datum to a multiplexer is determined based on a predefined real time download rate. When the determination indicates to send the received sensor datum to the multiplexer, the received sensor datum is sent to the multiplexer. When the determination does not indicate to send the received sensor datum to the multiplexer, the received sensor datum is written to a data file. The written sensor datum is sent from the data file to the multiplexer when there is an indicator of excess available bandwidth.

Liaghati, Amir Leon↗

Multifaceted radiation detection and classification system

A system identifying a source of radiation is provided. The system includes a radiation source detector and a radiation source identifier. The radiation source detector receives measurements of radiation; for one or more sources, generates a detection metric indicating whether that source is present in the measurements; and evaluates the detection metrics to detect whether a source is present in the measurements. When the presence of a source in the measurements is detected, the radiation source identifier for one or more sources, generates an identification metric indicating whether that source is present in the measurements; generates a null-hypothesis metric indicating whether no source is present in the measurements; evaluates the one or more identification metrics and the null-hypothesis metric to identify the source, if any, that is present in the measurements.

Labov, Simon E.↗

Thermal measurement apparatus and methods for anisotropic thermal materials

A system for characterizing thermal properties of thermally anisotropic heterogeneous samples includes a heating element, a first temperature sensing device, a second temperature sensing device, and a computing system. The heating element is positioned at a first location within a sample and heats the sample. The first temperature sensing device outputs data indicative of temperatures of the first location to the computing device. The second temperature sensing device outputs data indicative of temperatures of the second location to the computing device. The computing device computes a thermal conductivity of the sample based upon the temperatures of the first location. The computing device further outputs an indication of a portion of the sample to which the thermal conductivity pertains based upon the second temperatures.

Reyes, Karla Rosa↗

Quantifying and Understanding the Access Time to Dockless Micromobility: A Case Study in Washington, D.C.

Micromobility has been widely deployed in many cities. Similar as how access time/distance affects the travel demand to use public transit and informs transit system design, access time/distance to micromobility service measures its service efficiency and also serves as an equity indicator to inform city agencies from a regulation perspective. Though there is an increasing need to understand it, access to micromobility has not been sufficiently studied. This paper developed a framework to quantity the access time to dockless micromobility service (i.e., the minimum time needed to walk to reach the closest dockless micromobility vehicles). Based on the real-time vehicle location data collected from Washington, DC, this research quantified the access time to dockless micromobility, analyzed its spatial and temporal variation patterns and investigated its relationship with socio-demographic variables (i.e., population density, employment density and low-income population). The results revealed that the access time to dockless micromobility ranges between 0 to 4 minutes with the most frequently observed range of 0.5 to 1 minutes, and the city center area tends to have shorter access time than the outskirts areas. Results also indicate a quite stable access time level in DC with access time standard deviation of 0.2 to 0.5 minutes. After correlating the access time at census-block-group level with socio-demographic data, it was discovered that shorter access time usually aligns with larger population and employment density, and the proportion of low-income population was found not helpful with explaining the access time variation, which indicating a relatively equitable micromobility program.

access time↗

Systems and methods for in-situ calibration of scintillation spectrometer

A radiation spectrometer includes a scintillator, a photomultiplier, and one or more light-emitting diodes (LEDs). The scintillator receives radiation from the environment and emits light that is indicative of an energy of the radiation. The photomultiplier receives the light and outputs an electrical signal that is in turn indicative of the energy of the radiation. Spectral data can be generated based upon the electrical signal, wherein the spectral data indicates a number of radiation events in each of several energy bins. The one or more LEDs can emit LED light through the scintillator and toward the photomultiplier, wherein the LED light causes an LED peak in the spectral data that can be used to identify an absolute energy of radiation events in the spectral data.

Pfeifer, Kent B.↗

Devices and systems for measuring the state of a valve, and related methods

A device for measuring a state of a valve may include a housing configured to connect to a handle of a valve or a body of a valve, a sensor supported on one of the housing or the valve stem, and an indicator detectable by the sensor. The indicator may be configured to move relative to the sensor in response to movement of a valve stem or valve handle during opening and closing of the valve. The sensor may be configured to detect a position of the indicator to determine a state of the valve. Related systems and methods are also described.

Agarwal, Vivek↗

Tuple checkout with notify in coordination namespace system

A system and method for notifying a process about a creation or removal event of a named data element (NDE) in a coordination namespace distributed memory system. A controller runs methods to: generate a tuple corresponding to data generated by a requesting process, the tuple having a tuple name and data value; and generate a notification indicator in a pending notification list to indicate to one or more processes a notification of the creation or removal event associated with the corresponding tuple. Upon detecting the event performed on the tuple by a second process, the method further searches for NDEs in the distributed memory system having the same tuple name, and in response to determining an existence of an associated pending notification record in a pending notification list of records, notify each corresponding process of the one or more processes indicated in the list of the creation or removal event.

Jacob, Philip↗

Apparatus and method for providing workload distribution of threads among multiple compute units

In some examples, thermal aware optimization logic determines a characteristic (e.g., a workload or type) of a wavefront (e.g., multiple threads). For example, the characteristic indicates whether the wavefront is compute intensive, memory intensive, mixed, and/or another type of wavefront. The thermal aware optimization logic determines temperature information for one or more compute units (CUs) in one or more processing cores. The temperature information includes predictive thermal information indicating expected temperatures corresponding to the one or more CUs and historical thermal information indicating current or past thermal temperatures of at least a portion of a graphics processing unit (GPU). The logic selects the one or more compute units to process the plurality of threads based on the determined characteristic and the temperature information. The logic provides instructions to the selected subset of the plurality of CUs to execute the wavefront.

Rao, Karthik↗

Systems, methods, and media for high dynamic range imaging using single-photon and conventional image sensor data

In accordance with some embodiments, systems, methods, and media for high dynamic range imaging using single-photon and conventional image sensor data are provided. In some embodiments, the system comprises: first detectors configured to detect a level of photons proportional to incident photon flux; second detectors configured to detect arrival of individual photons; a processor programmed to: receive, from the first detectors, first values indicative of photon flux from a scene with a first resolution; receive, from the second detectors, second values indicative of photon flux from the scene with a lower resolution; provide a first encoder of a trained machine learning model first flux values based on the first values, provide the second encoder of the model second flux values; receive, as output, values indicative of photon flux from the scene; and generate a high dynamic range image based on the third plurality of values.

Gutierrez Barragan, Felipe↗

Controlling the operating speed of stages of an asynchronous pipeline

An asynchronous pipeline includes a first stage and one or more second stages. A controller provides control signals to the first stage to indicate a modification to an operating speed of the first stage. The modification is determined based on a comparison of a completion status of the first stage to one or more completion statuses of the one or more second stages. In some cases, the controller provides control signals indicating modifications to an operating voltage applied to the first stage and a drive strength of a buffer in the first stage. Modules can be used to determine the completion statuses of the first stage and the one or more second stages based on the monitored output signals generated by the stages, output signals from replica critical paths associated with the stages, or a lookup table that indicates estimated completion times.

Sadowski, Greg↗

Zero-Valent Iron Permeable Reactive Barrier to Remediate Volatile Organic Compounds in Groundwater - 20209

The US DOE-SRS, the US EPA, and the South Carolina Department of Health and Environmental Control determined it was appropriate to perform a non-time critical removal action at the P-Area Groundwater Operable Unit at the SRS to reduce the mass and downgradient transport of trichloroethylene in the P-Area groundwater plume. Contaminated groundwater discharges to a nearby stream, Steel Creek, within the SRS boundaries, resulting in trichloroethylene concentrations above the maximum contaminant level. Impact to surface water is limited in areal extent and supported by recently collected characterization data. The P-Area Groundwater Operable Unit encompasses the groundwater beneath an industrial area within SRS, P Area, where the P-Reactor once operated. The boundaries of the P-Area Groundwater Operable Unit extend northwest to Steel Creek, northeast toward PAR Pond, and southeast to Meyers Branch. Groundwater in the Upper Three Runs Aquifer of the P-Area Groundwater Operable Unit has been impacted by reactor and facility operations between 1954 and 1991, including tritium and volatile organic compounds. The P-Area surface units contributing to groundwater contamination were remediated as part of the P-Area Operable Unit in 2011. The P-Reactor closure is one of the first of its kind in the DOE Complex and is one of only a few full-sized production reactors in the US to undergo completion of final closure activities. The nature and extent of groundwater contamination was determined using a variety of investigative approaches such as groundwater monitoring wells, direct-push technology, and surface water samples. Groundwater contamination associated with trichloroethylene is primarily exhibited in a narrow plume that extends from the source area at P-Reactor and west to Steel Creek. Maximum contaminant level exceedances in groundwater occur over an area of ∼6.9 hectares for trichloroethylene with concentrations as high as 7.7 milligrams per liter. To the west of the P-Area facility area, the trichloroethylene groundwater plume is controlled by a buried geologic feature, assumed to be an old stream bed, that further narrows the groundwater plume in what has been designated as the 'neck area.' This narrowing of the groundwater plume provides an ideal location for a treatment barrier. The non-time critical removal action alternative chosen is to install a zero-valent iron permeable reactive barrier within the neck area of the trichloroethylene groundwater plume, perpendicular to groundwater flow direction. This technology will provide a treatment barrier that will reduce trichloroethylene groundwater concentrations by 90% and has an anticipated useful life of at least 25 years. A pre-design investigation was performed in the neck area to confirm site lithology, hydrogeology, geochemistry, and extent of trichloroethylene contamination prior to a final design. A treatability study, conducted as part of the pre-design investigation, indicated that the subsurface and groundwater in the PArea Groundwater Operable Unit is compatible with the zero-valent iron and will not lead to excessive buildup from mineralization/precipitation or biofouling. Probabilistic modeling was conducted using field and laboratory data to determine the expected performance of the zero-valent iron permeable reactive barrier. The model simulations indicated that a 3.81-centimeter thick barrier would provide greater than 90% reduction of trichloroethylene groundwater concentration. The final design of the zero-valent iron permeable reactive barrier is a barrier that will extend 80.5 linear meters in a 'zigzag' orientation to best transect the trichloroethylene plume and account for varying groundwater flow. The barrier will be installed from 13.7 meters below ground surface to 41.1 meters below ground surface for 65.8 linear meters and from 13.7 meters below ground surface to 36.6 meters below ground surface for 14.6 linear meters, the base of which is 'keyed' into a low permeability zone. The barrier is designed to a thickness of 10.2 centimeters, which was determined to reduce the trichloroethylene groundwater concentrations by greater than 90% with a safety factor of 2.67. A total of approximately 689 metric tons of zero-valent iron will be injected through 22 injection wells spaced 3.66 meters apart, using guar to suspend the zero-valent iron. Zero-valent iron permeable reactive barrier construction will be monitored through 23 installed resistivity receivers offset 7.32 meters from the zerovalent iron permeable reactive barrier. The zero-valent iron will be energized with a low-voltage 100 Hertz signal during injection and will be monitored using the resistivity receivers to ensure complete coalescence of the zero-valent iron permeable reactive barrier. The zero-valent iron was sized to have a hydraulic conductivity greater than the natural subsurface, thus promoting groundwater flow through the barrier. As contaminated groundwater contacts the zero-valent iron, volatile organic compounds, including trichloroethylene, are immediately degraded to harmless compounds such as ethylene. The performance of the zero-valent iron permeable reactive barrier will be monitored using three upgradient monitoring well clusters, six downgradient monitoring well clusters, and four in-wall monitoring wells. The in-wall monitoring wells will indicate immediate reduction of trichloroethylene mass in the groundwater and allow analyses of the zero-valent iron permeable reactive barrier health. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Consequence Analysis of Residual Water in a Storage Canister - 20484

Recent observations from projects sponsored under the DOE-Nuclear Energy Spent Fuel and Waste Disposition campaign show that residual free water, well above the 0.4 gm-moles that correspond to a 3 torr rebound pressure after a 30-minute hold following prototypic drying, may remain within SNF canisters used for long-term dry storage. Specifically, experimental observations in an Integrated Research Project showed subzero temperatures and a local pocket of frozen water in a mockup fuel assembly subjected to an industry practiced drying process. In gas sampling and analysis from the High Burnup (HBU) Demonstration project, using a fully loaded and dried SNF canister, indicated presence of 100 g of residual water had remained in the canister. The effects of residual water in terms of potential adverse impacts on the condition of the SNF and the canister internals during long-term dry storage has been rigorously evaluated to address inadvertent residual water contents. The impact of residual water on the fuel and canister internals, with a focus on the oxidation of the cladding and of postulated exposed (breached-clad) fuel, were evaluated using an integrated set of time-dependent environmental conditions with semi-empirical materials oxidation models. An 'integration model,' with coupled sub-models, developed and previously used by the Center for Nuclear Waste Regulatory Analysis (CNWRA), was applied and expanded with improved sub-models for water radiolysis, and for cladding and fuel oxidations. Cladding oxidation models for various alloys were developed using the rate constants for various cladding alloys in the dry storage temperature range. A burnup-dependent fuel oxidation model was developed; it accounted for inhibition effect of fission products on fuel oxidation rates. The potential for extension of the initial breach flaw (1 mm hole) was evaluated by two separate mechanics criteria. In the first case, a critical cladding strain criterion was used. In the second case, a critical stress intensity was used to evaluate stability of a planar axial flaw postulate. A failure condition exists when a sufficient amount of fuel oxidation (at the postulated breached-clad location) causes fuel pellet swelling to load the cladding to meet a mechanics criterion for flaw extension. The integration model's results provide the following insights. The radiolysis-generated oxygen is consumed with a partitioning between the cladding and the fuel. The extent of cladding oxidation is no more than 2 μm additional consumption of the cladding metal even with 10 moles of residual water, indicating that changes in cladding conditions due to water are expected to be negligible. The conditions for cladding failure (breach opening size extension) directly correlates with the extent of fuel oxidation. Fuel oxidation significant to extend the breach could occur even with 5.5 moles of residual water. The results indicate that fuel oxidation vis-a-vis cladding oxidation is more likely under a higher radiation field, i.e., when radiolytic decomposition of the residual water occurs in few years compared to several decades, and that the conditions to cause failure are increased with fuel and cladding temperatures approaching the peak storage temperature limit of 400 deg. C. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Site Integration and Regulatory Considerations for a Nuclear Power Plant Colocated with Industrial Facilities: Colocation Studies for a Petroleum Refinery, Methanol Plant, and Wood Pulp Plant

This research explores the colocation of nuclear power plants (NPPs) with industrial applications. Three existing industrial sites were considered to demonstrate the siting process and illuminate technological gaps for future work. The three applications demonstrated for colocation here are a petroleum refinery, a methanol production plant, and a pulp and paper plant. This study uses a modified version of the EPRI siting criteria to explore the geological and demographic characteristics of the location of the current industrial site, as well as exploring external hazards from the industrial plant and its surrounding land use. Data was collected from public databases to estimate site characteristics. We then discuss how the site characteristics may impact the ability to colocate an NPP with an industrial application. The application site and 5 additional sites were explored for each application to give a general indication of the siting implications for an NPP in each area. The hazards for each industrial application was also explored to determine how colocation may impact reactor safety. The following gaps have been identified and should be explored in future research on colocation of NPPs with petroleum refineries, methanol plants, and pulp and paper plants: - There is a variety of industrial use, hazards, and pipelines in the surrounding area. A more thorough review of these hazards should be considered for colocation. - In general, the whole region around some applications seems to have softer soil, with implications for large site preparation costs. Further site investigations should prioritize looking into the geotechnical conditions. - Applications along coastlines are susceptible to flooding and hurricanes. The benefits of colocation should be weighed against the potential design implications. - The benefits of natural gas pipeline infrastructure in place should be explored further. If heat supply from the NPP is not required or not feasible due to the distance between the NPP and the application, there may be an opportunity to supply hydrogen to the plant through an existing pipeline. - Because there are several collocated industrial plants in the regions for the refinery and methanol plant, the benefits of sharing resources from the NPP should be explored further. This may open up additional sites for colocation. The following knowledge gaps were identified for the colocation of NPPs with these three industries, and industrial applications in general. These gaps are: - While the STAND tool contains many important characteristics for the reactor siting process, it is not calibrated for the colocation of NPPs with industrial facilities. - There are aspects of both the NPP and industrial application that need to be quantified for a siting analysis. Particularly, we need to understand the water intake requirements for NPPs and each application. - Further work may focus on adapting the STAND site comparison methodology to comparison of sites for co-location. This will involve using the data documented in this report as a starting point and performing a comprehensive and quantitative comparison. - Without spending significant resources, it would be impossible to gather data for each site to evaluate all aspects of siting. One approach to finding data and understanding its implications to siting is looking at FSARs for existing plants. For example, most sites considered in this study have small Vs30 values, indicating soft soil. However, there are NPPs located in the vicinity of most of the sites (e.g., Waterford Steam Electric Station near New Orleans) and reviewing available site characteristics and geotechnical data for these NPPs, might provide further information for siting. - The siting analysis in this study indicates that colocation of the NPP with the industrial site could be difficult based on external hazards, cooling requirements, weather, or population. We need to determine the impact of distance between the two facilities on cost and quality of energy transport. - This study did not touch on socioeconomic impacts for NPP colocation with industrial facilities. The input-output analysis methodology could be applied to the communities referenced in this study to determine the socioeconomic impact of these projects. - Similarly, the impacts of colocation on emergency planning was not explored in this study. The impacts on emergency planning infrastructure are somewhat related to the socioeconomic impacts, and could be explored using a similar methodology. - This study also did not address physical and cybersecurity, which will be important aspects of co-location [ref] . Cybersecurity will be important, regardless of the distance, but physical security will be important if the facilities are located very closely. Physical security might also be important for the steam lines between the plants, unless they are determined to be non-safety significant. - In many site l

08 HYDROGEN↗

Evaluating the Feasibility of Measuring and Analyzing Strain Caused by Changes in Barometric Pressure in the Vadose Zone

Changes in barometric pressure propagate into the subsurface where they can affect water level measurements in wells and cause vertical strain. Previous strain sensors were developed to measure vertical strain, but they were limited to measurements at a single depth, making it difficult to evaluate strains from a migrating pressure wave. Technology known as Coherence-length-gated Microwave Photonics Interferometry (CMPI) uses optical fiber sensors to measure strain at multiple locations. It has the potential to detect strain caused by variations in barometric pressure at multiple depths in the subsurface. The goal of this study is to evaluate the feasibility of using this technology to record the changes in vertical strain in the vadose zone from small fluctuations in air pressure. Propagation of these air pressure fluctuations is affected by hydrogeological properties such as water content and permeability. A second goal of this study is to evaluate how these properties affect the air pressure distribution, strain, and gas-phase diffusivity with a long-term goal of using strain to monitor the vadose zone. The focus of this study is on a suite of laboratory experiments that used a sand-filled column with an open head space. The CMPI fiber was packaged and embedded along the axis of the column to measure the strain at multiple locations while air pressure transducers were installed through the wall of the column. Small periodic fluctuations in air pressure, similar to barometric pressure fluctuations, were created in the head space of the column using an audio driven speaker driven at 4 Hz using a sinusoidal signal created by a function generator. Then, the fluctuations propagated along the column where they were measured by the transducers and recorded as functions of time. Initial tests were conducted using dry sand, but then additional tests were conducted after injecting water into the column, which changed the hydrologic and mechanical properties. Another experiment was conducted after creating a thin barrier to air flow, which was designed to simulate a thin layer of saturated ground during rainfall. A final experiment was conducted by changing the grain size of the material to create a heterogeneity in the upper half of the column. The suite of six experiments was conducted to highlight effects of variations in water content and heterogeneities on air pressure and vertical strain. Numerical simulations were also created to evaluate the laboratory data and to provide a baseline analysis for the results. The numerical simulations used the governing equations to linear poroelasticity and two-phase flow with boundary conditions representing the experiments. The conceptual model for strain caused by barometric pressure recognizes that a fluctuating barometric pressure causes fluctuations in the air pore pressure that decrease in amplitude and lag in time with increase depth. The pressure distribution results in two different loads that cause strain: 1.) a mechanical load as the barometric pressure acts on the ground surface; and 2.) pressure loading in the pore space. The results show that the total vertical strain is a contribution of both of these loads, and this is the strain that was observed in the laboratory. The lab experiments show that both air pressure and strain vary as sinusoids that propagate with depth. The amplitude of the air pressure and strain decrease as a function of depth in all the conditions that were evaluate. For example, in the dry sand, the amplitude of the air pressure decreases from 25 Pa at the head space to 5 Pa at a depth of 70 cm, whereas the amplitude of the strain decreases from 0.15 to 0.06 µε over the same depth interval. In many cases the amplitudes decrease is approximately negative exponential functions of depth. When water was injected into the sand and the saturation increased, the amplitude of the air pressure increased in the partially saturated sand but decreased sharply to zero where the soil was saturated. The strain decreased with depth, but the transition from partially to fully saturated conditions had little effect on the strain profile, even though it had a major effect on the air pressure. This apparently is because strain is caused by variations in both water and air pressure. The fluctuating air pressure caused the water pressure to fluctuate, which caused strain throughout the column. Phase delay of the air pressure and the strain both increase as linear to bi-linear functions of depth. The phase delays indicate that pressure propagates at a velocity of 7 to 8 m/s in dry or partially saturated sand, but it drops by more than an order of magnitude in the vicinity of the capillary fringe. The phase delays indicate the strain propagates faster than the pressure. The data indicate that the strain propagates from 1.2 to more than 4x faster than the pressure. Switching from sand to silt in the column caused the velocity of the pressure to drop by roughly half for both pressures, but curiously, it had little effect on the velocity of the strain.

54 ENVIRONMENTAL SCIENCES↗