Quality assurance for image-guided radiation therapy utilizing CT-based technologies: A report of the AAPM TG-179

Purpose: Commercial CT-based image-guided radiotherapy (IGRT) systems allow widespread management of geometric variations in patient setup and internal organ motion. This document provides consensus recommendations for quality assurance protocols that ensure patient safety and patient treatment fidelity for such systems. Methods: The AAPM TG-179 reviews clinical implementation and quality assurance aspects for commercially available CT-based IGRT, each with their unique capabilities and underlying physics. The systems described are kilovolt and megavolt cone-beam CT, fan-beam MVCT, and CT-on-rails. A summary of the literature describing current clinical usage is also provided. Results: This report proposes a generic quality assurance program for CT-based IGRT systems in an effort to provide a vendor-independent program for clinical users. Published data from long-term, repeated quality control tests form the basis of the proposed test frequencies and tolerances.Conclusion: A program for quality control of CT-based image-guidance systems has been produced, with focus on geometry, image quality, image dose, system operation, and safety. Agreement and clarification with respect to reports from the AAPM TG-101, TG-104, TG-142, and TG-148 has been addressed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

High-resolution phase-contrast imaging of biological specimens using a stable betatron X-ray source in the multiple-exposure mode

Abstract Phase-contrast imaging using X-ray sources with high spatial coherence is an emerging tool in biology and material science. Much of this research is being done using large synchrotron facilities or relatively low-flux microfocus X-ray tubes. An alternative high-flux, ultra-short and high-spatial-coherence table-top X-ray source based on betatron motions of electrons in laser wakefield accelerators has the promise to produce high quality images. In previous phase-contrast imaging studies with betatron sources, single-exposure images with a spatial resolution of 6–70 μ m were reported by using large-scale laser systems (60–200 TW). Furthermore, images obtained with multiple exposures tended to have a reduced contrast and resolution due to the shot-to-shot fluctuations. In this article, we demonstrate that a highly stable multiple-exposure betatron source, with an effective average source size of 5 μ m, photon number and pointing jitters of <5% and spectral fluctuation of <10%, can be obtained by utilizing ionization injection in pure nitrogen plasma using a 30–40 TW laser. Using this source, high quality phase-contrast images of biological specimens with a 5- μ m resolution are obtained for the first time. This work shows a way for the application of high resolution phase-contrast imaging with stable betatron sources using modest power, high repetition-rate lasers.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Optimizing Cardiac CTA Acquisition in Congenital Heart Disease

Purpose of Review: The purpose of this review of performance of cardiac computed tomographic angiography (CCTA) in patients with congenital heart disease (CHD) is to describe a strategy for optimizing CCTA protocols for various forms of CHD at diagnosis and throughout the lifetime of a patient. Recent Findings: Recent expert consensus statements provide key recommendations for patient selection and technical performance of CCTA with tips to optimize contrast injection, scan acquisition, and understanding anatomy and postoperative changes in patients with CHD. Spectral CT will become invaluable in acquiring image data which has potential for enabling improved image quality and perhaps physiologic information. Summary: CCTA is an important non-invasive imaging modality for making initial diagnosis and providing follow-up imaging in patients of all ages with CHD. Optimization of imaging protocols requires combined expertise in all forms of CHD, surgical palliation procedures, and knowledge of surgical options for CHD surgery.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Five-second STEM dislocation tomography for 300 nm thick specimen assisted by deep-learning-based noise filtering

Scanning transmission electron microscopy (STEM) is suitable for visualizing the inside of a relatively thick specimen than the conventional transmission electron microscopy, whose resolution is limited by the chromatic aberration of image forming lenses, and thus, the STEM mode has been employed frequently for computed electron tomography based three-dimensional (3D) structural characterization and combined with analytical methods such as annular dark field imaging or spectroscopies. However, the image quality of STEM is severely suffered by noise or artifacts especially when rapid imaging, in the order of millisecond per frame or faster, is pursued. Here we demonstrate a deep-learning-assisted rapid STEM tomography, which visualizes 3D dislocation arrangement only within five-second acquisition of all the tilt-series images even in a 300 nm thick steel specimen. The developed method offers a new platform for various in situ or operando 3D microanalyses in which dealing with relatively thick specimens or covering media like liquid cells are required.

47 OTHER INSTRUMENTATION↗

A statistical, task-based evaluation method for three-dimensional x-ray breast imaging systems using variable-background phantoms

Purpose: For the last few years, development and optimization of three-dimensional (3D) x-ray breast imaging systems, such as digital breast tomosynthesis (DBT) and computed tomography, have drawn much attention from the medical imaging community, either academia or industry. However, there is still much room for understanding how to best optimize and evaluate the devices over a large space of many different system parameters and geometries. Current evaluation methods, which work well for 2D systems, do not incorporate the depth information from the 3D imaging systems. Therefore, it is critical to develop a statistically sound evaluation method to investigate the usefulness of inclusion of depth and background-variability information into the assessment and optimization of the 3D systems. Methods: In this paper, we present a mathematical framework for a statistical assessment of planar and 3D x-ray breast imaging systems. Our method is based on statistical decision theory, in particular, making use of the ideal linear observer called the Hotelling observer. We also present a physical phantom that consists of spheres of different sizes and materials for producing an ensemble of randomly varying backgrounds to be imaged for a given patient class. Lastly, we demonstrate our evaluation method in comparing laboratory mammography and three-angle DBT systems for signal detection tasks using the phantom's projection data. We compare the variable phantom case to that of a phantom of the same dimensions filled with water, which we call the uniform phantom, based on the performance of the Hotelling observer as a function of signal size and intensity. Results: Detectability trends calculated using the variable and uniform phantom methods are different from each other for both mammography and DBT systems. Conclusions: Our results indicate that measuring the system's detection performance with consideration of background variability may lead to differences in system performance estimates and comparisons. For the assessment of 3D systems, to accurately determine trade offs between image quality and radiation dose, it is critical to incorporate randomness arising from the imaging chain including background variability into system performance calculations.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Multiresolution edge detection using enhanced fuzzy c-means clustering for ultrasound image speckle reduction

Purpose: Speckle suppression in ultrasound (US) images of various anatomic structures via a novel speckle noise reduction algorithm. Methods: The proposed algorithm employs an enhanced fuzzy c-means (EFCM) clustering and multiresolution wavelet analysis to distinguish edges from speckle noise in US images. The edge detection procedure involves a coarse-to-fine strategy with spatial and interscale constraints so as to classify wavelet local maxima distribution at different frequency bands. As an outcome, an edge map across scales is derived whereas the wavelet coefficients that correspond to speckle are suppressed in the inverse wavelet transform acquiring the denoised US image. Results: A total of 34 thyroid, liver, and breast US examinations were performed on a Logiq 9 US system. Each of these images was subjected to the proposed EFCM algorithm and, for comparison, to commercial speckle reduction imaging (SRI) software and another well-known denoising approach, Pizurica's method. The quantification of the speckle suppression performance in the selected set of US images was carried out via Speckle Suppression Index (SSI) with results of 0.61, 0.71, and 0.73 for EFCM, SRI, and Pizurica's methods, respectively. Peak signal-to-noise ratios of 35.12, 33.95, and 29.78 and edge preservation indices of 0.94, 0.93, and 0.86 were found for the EFCM, SIR, and Pizurica's method, respectively, demonstrating that the proposed method achieves superior speckle reduction performance and edge preservation properties. Based on two independent radiologists’ qualitative evaluation the proposed method significantly improved image characteristics over standard baseline B mode images, and those processed with the Pizurica's method. Furthermore, it yielded results similar to those for SRI for breast and thyroid images significantly better results than SRI for liver imaging, thus improving diagnostic accuracy in both superficial and in-depth structures. Conclusions: A new wavelet-based EFCM clustering model was introduced toward noise reduction and detail preservation. The proposed method improves the overall US image quality, which in turn could affect the decision-making on whether additional imaging and/or intervention is needed.

60 APPLIED LIFE SCIENCES↗

TU-C-9A-01: IROC Organization and Clinical Trial Credentialing

As a response to recommendations from a report from the Institute of Medicine, NCI is reorganizing it clinical trial groups into a National Clinical Trial Network (NCTN) that consists of four adult groups (Alliance, ECOGACRIN, NRG, and SWOG) and one children’s group (COG). NRG will house CIRO, a center to promote innovative radiation therapy research and intergroup collaboration in radiation. The quality assurance groups that support clinical trials have also been restructured. ITC, OSU Imaging corelab, Philadelphia Imaging core-lab, QARC, RPC, and RTOGQA have joined together to create the Imaging and Radiation Oncology Core (IROC) Group. IROC’s mission is to provide integrated radiation oncology and diagnostic imaging quality control programs in support of the NCI’s NCTN thereby assuring high quality data for clinical trials designed to improve the clinical outcomes for cancer patients worldwide. This will be accomplished through five core services: site qualification, trial design support, credentialing, data management, case review.These changes are important for physicist participating in NCI clinical trials to understand. We will describe in detail the IROC’s activities and five core services so that as a user, the medical physicist can learn how to efficiently utilize this group. We will describe common pitfalls encountered in credentialing for current protocols and present methods to avoid them. These may include the which benchmarks are required for NSABP B-51/RTOG 1304 and how to plan them as well as tips for phantom planning. We will explain how to submit patient and phantom cases in the TRIAD system used by IROC. Learning Objectives: To understand the basic organization of IROC, its mission and five core services To learn how to use TRIAD for patient and phantom data submission To learn how to avoid common pitfalls in credentialing for current trials.

60 APPLIED LIFE SCIENCES↗

TU-H-BRA-01: The Physics of High Power Radiofrequency Isolation in a Novel Compact Linear Accelerator Based MRI Guided Radiation Therapy System

Purpose: To develop a method for isolating the radiofrequency waves emanating from linear accelerator components from the magnetic resonance imaging (MRI) system of an integrated MRI-linac. Methods: An MRI-guided radiation therapy system has been designed that integrates a linear accelerator with simultaneous MR imaging. The radiofrequency waves created by the accelerating process would degrade MR image quality, so a method for containing the radiofrequency waves and isolating the MR imager from them was developed. The linear accelerator radiofrequency modulator was placed outside the room, so a filter was designed to eliminate the radiofrequency corresponding to the proton Larmour frequency of 14.7 MHz. Placing the radiofrequency emitting components in a typical Faraday cage would have reduced the radiofrequency emissions, but the design would be susceptible to small gaps in the shield due to the efficiency of the Faraday cage reflecting internal radiofrequency emissions. To reduce internal radiofrequency reflections, the Faraday cage was lined with carbon fiber sheets. Carbon fiber has the property of attenuating the radiofrequency energy so that the overall radiofrequency field inside the Faraday cage is reduced, decreasing any radiofrequency energy emitted from small gaps in the cage walls. Results: Within a 1.2 MHz band centered on the Larmor frequency, the radiofrequency (RF) leakage from the Faraday cage was measured to be −90 dB with no RF on, −40 dB with the RF on and no shield, returning to −90 dB with the RF on and shields in place. The radiofrequency filter attenuated the linear accelerator modulator emissions in the 14.7 MHz band by 70 dB. Conclusions: One of the major challenges in designing a compact linear accelerator based MRI-guided radiation therapy system, that of isolating the high power RF system from the MRI, has been solved. The measured radiofrequency emissions are sufficiently small to enable system integration. This research was funded by ViewRay, Inc., Oakwood, OH.

60 APPLIED LIFE SCIENCES↗

Linear image reconstruction for a diffuse optical mammography system in a noncompressed geometry using scattering fluid

Diffuse optical tomography (DOT) is a potential new imaging modality to detect or monitor breast lesions. Recently, Philips developed a new DOT system capable of transmission and fluorescence imaging, where the investigated breast is hanging freely into the measurement cup containing scattering fluid. We present a fast and robust image reconstruction algorithm that is used for the transmission measurements. The algorithm is based on the Rytov approximation. We show that this algorithm can be used over a wide range of tissue optical properties if the reconstruction is adapted to each patient. We use estimates of the breast shape and average tissue optical properties to initialize the reconstruction, which improves the image quality significantly. We demonstrate the capability of the measurement system and reconstruction to image breast lesions by clinical examples.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Advanced Meteorological Temperature Sounder (AMTS) study

The results of a system definition study (theoretical) for an Advanced Meteorological Temperature Sounder (AMTS) is described. From the data the atmospheric temperature and humidity profiles can be determined over the entire earth's surface with a spatial resolution of 45 km. x 45 km; amounts and type of cloud cover as well as surface temperatures of the earth are also determined. The major purpose of the study was to determine the feasibility of cooling twenty-eight detectors to the 80-90 Kelvin region by means of a radiative cooler. Other related considerations were achieving high signal-to-noise ratios, maximizing optical throughput through the grating spectrometer, and reducing preamplifier noise. A detailed optical design of an f/5 Ebert-Fastie spectrometer was carried out to verify that image quality is adequate; field lenses near the spectrometer focal plane were designed to image the grating onto the smallest size detectors for each channel.

Source record↗

An information theory characterization of radar images and a new definition for radiometric resolution

The noise properties of the radar image formation process are used in the present modeling of a communication channel in which the desired target properties are the information transmitted, and the final image represents the received signal. The average information rate over this communication channel is calculated together with appropriate bounds and approximations, and is found to be small on a per-sample basis. As a result, many samples must be averaged to allow for the discrimination, or classification, of several levels of target reflectivity. These information rate properties are consistent with known results concerning target detection and image quality in speckle, and the rate is applicable to the definition of radar image radiometric resolution. Radiometric resolution is functionally related to the degree of noncoherent averaging performed by the sensor.

Frost, V. S.↗

A Deployable Primary Mirror for Space Telescopes

NASA Langley Research Center, Composite Optics, Inc., and Nyma/ADF have developed jointly a deployable primary mirror for space telescopes that combines over five years of research on deployment of optical-precision structures and over ten years of development of fabrication techniques for optical-precision composite mirror panels and structures. The deployable mirror is directly applicable to a broad class of non-imaging "lidar" (Light direction and ranging) telescopes whose figure-error requirements are in the range of one to ten microns RMS. Furthermore, the mirror design can be readily modified to accommodate imaging-quality reflector panels and active panel-alignment control mechanisms for application to imaging telescopes. The present paper: 1) describes the deployable mirror concept; 2) explains the status of the mirror development; and 3) provides some technical specifications for a 2.55- m-diameter, proof-of-concept mirror.

Lake, Mark S.↗

A Deployable Primary Mirror for Space Telescopes

NASA Langley Research Center, Composite Optics, Inc., and Nyma/ADF have developed jointly a deployable primary mirror for space telescopes that combines over five years of research on deployment of optical-precision structures and over ten years of development of fabrication techniques for optical-precision composite mirror panels and structures. The deployable mirror is directly applicable to a broad class of non-imaging "lidar" (light direction and ranging) telescopes whose figure-error requirements are in the range of one to ten microns RMS. Furthermore, the mirror design can be readily modified to accommodate imaging-quality reflector panels and active panel-alignment control mechanisms for application to imaging telescopes. The present paper: 1) describes the deployable mirror concept; 2) explains the status of the mirror development; and 3) provides some technical specifications for a 2.55-m-diameter, proof-of-concept mirror.

Lake, Mark S.↗

A Deployable Primary Mirror for Space Telescopes

NASA Langley Research Center, Composite Optics, Inc., and Nyma/ADF have developed jointly a deployable primary mirror for space telescopes that combines over five years of research on deployment of optical-precision structures and over ten years of development of fabrication techniques for optical-precision composite mirror panels and structures. The deployable mirror is directly applicable to a broad class of non-imaging "lidar" (light direction a nd ranging) telescopes whose figure-error requirements are in the range of one to ten microns RMS. Furthermore, the mirror design can be readily modified to accommodate imaging-quality reflector panels and active panel-alignment control mechanisms for application to imaging telescopes. The present paper: 1) describes the deployable mirror concept; 2) explains the status of the mirror development; and 3) provides some technical specifications for a 2.55- m-diameter, proof-of-concept mirror. Keywords: precision deployment, hinge joint, latch joint, deployable structures, fabrication, space telescopes, optical instruments, microdynamics.

Lake, Mark S.↗

New Techniques for the Next Far Ultraviolet Spectroscopic Mission

The Far Ultraviolet Spectroscopic Explorer (FUSE) has been a great success, and has addressed many critical scientific questions (Moos, et al, 2000). However, it has also highlighted the need for even more powerful instrumentation in the 900- 1200 A, regime. In particular, significantly increased effective area will permit the pursuit of additional scientific programs currently impractical or impossible with FUSE. It is unlikely that FUSE will last more than a few more years. Nor is it likely that any large scale UV-optical follow-on to HST (such as SUVO) will include the 900-1200 A, bandpass. However, FUSE remains well oversubscribed and continues to perform excellent science. Therefore, a MIDEX class mission in the next 4-6 years that could significantly improve on the FUSE capabilities would be a powerful scientific tool that would be of great utility to the astronomical community. It would open up new scientific programs if it can improve on the sensitivity of FUSE by an order of magnitude. We have identified a powerful technique for efficient, high-resolution spectroscopy in the FUV (and possibly the EUV) that may provide exactly what is needed for such a mission To achieve a factor of 10 improvement in effective area, we propose using a large (meter class), low-cost, grazing incidence metal optics. This would produced in a manner similar to the EUVE mirrors (Green, et al, 1986), using diamond turning to create the optical figure followed by uncontrolled polishing to achieve a high quality surface. This process will introduce significant figure errors that will degrade the image quality. However, if a holographic grating is employed, which has utilized the actual telescope in the recording geometry, all wavefront errors will be automatically corrected in the end-to-end spectrometer, and high quality spectroscopy will be possible with low quality (and low-cost) optics. In this way a MIDEX class FUSE can be proposed with 10 times the effective area of the current instrument.

Green, James C.↗

Extreme Tele-Echocardiography: Methodology for Remote Guidance of In-flight Echocardiography Aboard the International Space Station

Echocardiography is ideally suited for cardiovascular imaging in remote environments, but the expertise to perform it is often lacking. In 2001, an ATL HDI5000 was delivered to the International Space Station (ISS). The instrument is currently being used in a study to investigate the impact of long-term microgravity on cardiovascular function. The purpose of this report is to describe the methodology for remote guidance of echocardiography in space. Methods: In the year before launch of an ISS mission, potential astronaut echocardiographic operators participate in 5 sessions to train for echo acquisitions that occur roughly monthly during the mission, including one exercise echocardiogram. The focus of training is familiarity with the study protocol and remote guidance procedures. On-orbit, real-time guidance of in-flight acquisitions is provided by a sonographer in the Telescience Center of Mission Control. Physician investigators with remote access are able to relay comments on image optimization to the sonographer. Live video feed is relayed from the ISS to the ground via the Tracking and Data Relay Satellite System with a 2 second transmission delay. The expert sonographer uses these images along with two-way audio to provide instructions and feedback. Images are stored in non-compressed DICOM format for asynchronous relay to the ground for subsequent off-line analysis. Results: Since June, 2009, a total of 19 resting echocardiograms and 4 exercise studies have been performed in-flight. Average acquisition time has been 45 minutes, reflecting 26,000 km of ISS travel per study. Image quality has been adequate in all studies, but remote guidance has proven imperative for fine-tuning imaging and prioritizing views when communication outages limit the study duration. Typical resting studies have included 12 video loops and 21 still-frame images requiring 750 MB of storage. Conclusions: Despite limited crew training, remote guidance allows research-quality echocardiography to be performed by non-experts aboard the ISS. Analysis is underway and additional subjects are being recruited to define the impact of microgravity on cardiac structure and systolic and diastolic function.

Martin, David↗

SU-C-209-06: Improving X-Ray Imaging with Computer Vision and Augmented Reality

Purpose: To determine the feasibility of using a computer vision algorithm and augmented reality interface to reduce repeat rates and improve consistency of image quality and patient exposure in general radiography. Methods: A prototype device, designed for use with commercially available hardware (Microsoft Kinect 2.0) capable of depth sensing and high resolution/frame rate video, was mounted to the x-ray tube housing as part of a Philips DigitalDiagnost digital radiography room. Depth data and video was streamed to a Windows 10 PC. Proprietary software created an augmented reality interface where overlays displayed selectable information projected over real-time video of the patient. The information displayed prior to and during x-ray acquisition included: recognition and position of ordered body part, position of image receptor, thickness of anatomy, location of AEC cells, collimated x-ray field, degree of patient motion and suggested x-ray technique. Pre-clinical data was collected in a volunteer study to validate patient thickness measurements and x-ray images were not acquired. Results: Proprietary software correctly identified ordered body part, measured patient motion, and calculated thickness of anatomy. Pre-clinical data demonstrated accuracy and precision of body part thickness measurement when compared with other methods (e.g. laser measurement tool). Thickness measurements provided the basis for developing a database of thickness-based technique charts that can be automatically displayed to the technologist. Conclusion: The utilization of computer vision and commercial hardware to create an augmented reality view of the patient and imaging equipment has the potential to drastically improve the quality and safety of x-ray imaging by reducing repeats and optimizing technique based on patient thickness. Society of Pediatric Radiology Pilot Grant; Washington University Bear Cub Fund.

60 APPLIED LIFE SCIENCES↗

Evaluation of respiratory and cardiac motion correction schemes in dual gated PET/CT cardiac imaging

Purpose: Cardiac imaging suffers from both respiratory and cardiac motion. One of the proposed solutions involves double gated acquisitions. Although such an approach may lead to both respiratory and cardiac motion compensation there are issues associated with (a) the combination of data from cardiac and respiratory motion bins, and (b) poor statistical quality images as a result of using only part of the acquired data. The main objective of this work was to evaluate different schemes of combining binned data in order to identify the best strategy to reconstruct motion free cardiac images from dual gated positron emission tomography (PET) acquisitions. Methods: A digital phantom study as well as seven human studies were used in this evaluation. PET data were acquired in list mode (LM). A real-time position management system and an electrocardiogram device were used to provide the respiratory and cardiac motion triggers registered within the LM file. Acquired data were subsequently binned considering four and six cardiac gates, or the diastole only in combination with eight respiratory amplitude gates. PET images were corrected for attenuation, but no randoms nor scatter corrections were included. Reconstructed images from each of the bins considered above were subsequently used in combination with an affine or an elastic registration algorithm to derive transformation parameters allowing the combination of all acquired data in a particular position in the cardiac and respiratory cycles. Images were assessed in terms of signal-to-noise ratio (SNR), contrast, image profile, coefficient-of-variation (COV), and relative difference of the recovered activity concentration. Results: Regardless of the considered motion compensation strategy, the nonrigid motion model performed better than the affine model, leading to higher SNR and contrast combined with a lower COV. Nevertheless, when compensating for respiration only, no statistically significant differences were observed in the performance of the two motion models considered. Superior image SNR and contrast were seen using the affine respiratory motion model in combination with the diastole cardiac bin in comparison to the use of the whole cardiac cycle. In contrast, when simultaneously correcting for cardiac beating and respiration, the elastic respiratory motion model outperformed the affine model. In this context, four cardiac bins associated with eight respiratory amplitude bins seemed to be adequate. Conclusions: Considering the compensation of respiratory motion effects only, both affine and elastic based approaches led to an accurate resizing and positioning of the myocardium. The use of the diastolic phase combined with an affine model based respiratory motion correction may therefore be a simple approach leading to significant quality improvements in cardiac PET imaging. However, the best performance was obtained with the combined correction for both cardiac and respiratory movements considering all the dual-gated bins independently through the use of an elastic model based motion compensation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗