Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “heating systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 865 records · Page 48

COMPUTATION FLUID DYNAMICS ANALYSIS FOR GENERIC SMALL MODULAR REACTOR CONTAINMENT SEPARATE EFFECTS TEST

It is desirable for fourth-generation Small Modular Reactors to be passively cooled in standard and accident operations. Passive Containment Cooling Systems can reject heat from the containment structure, without using pumps or blowers. The targeted design containment structure is a large, domed, stainless steel, cylindrical vessel. In a postulated Design Basis Accident, steam will flash inside containment. Steam condensation occurs on the inner containment wall and transfers heat through the steel containment into a large body of water known as the annular reservoir (AR) surrounding the vessel serving as the ultimate heat sink. Natural circulation drives the flow in the AR and heat will be released to the environment by evaporation of water. Unique containment geometry requires a separate effects test (SET) facility for the verification and validation of the computer code and evaluation model development and assessment for reactor licensing efforts. In this study, STAR-CCM+, a computational fluid dynamics (CFD) code was used to inform the decision-making process on the design of the SET. The CFD simulation modeled, a two-phase turbulent flow with fluid film development and heat transfer for different containment geometries. The Reactor Excursion and Leak Analysis Program will also be used in a code-to-code verification against the CFD results.

21 - SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLAN↗

Cost-Optimized Cold Climate Heat Pump Development and Field Test

Cold climate heat pumps (CCHPs) expand the heat pump market to climates where heating demand is dominant. They can achieve more than 70% energy savings compared with electric resistance heating and operate at lower cost than using tank-stored propane to fuel a furnace. A high-efficiency heat pump with a heating seasonal performance factor (HSPF)—as defined by the Air-Conditioning, Heating, and Refrigeration Institute (AHRI 2008)—greater than 10.0 would be more efficient than gas heating in terms of source energy. However, developing a cost-effective CCHP involves some challenges. A typical single-speed, air-source heat pump (ASHP) with an HSPF of 7.7 Btu/Wh does not work well under cold outdoor temperature conditions typical of cold climate locations for four major reasons: 1. Discharge temperature is too high—The low suction pressure and high compression pressure ratio at low ambient temperatures causes high compressor discharge temperatures in excess of the maximum limit for many of the compressors on the market. Furthermore, system charge of a heat pump is usually optimized in the cooling mode, which leads to overcharge conditions in the heating mode, further increasing the discharge temperature. 2. Heating capacity is insufficient if sized to meet the building design cooling load— Heating capacity of a single-speed heat pump decreases with ambient temperature. The heating capacity at -13°F (-25°C) typically decreases to 20%–40% of the rated heating capacity at 47°F (8.3°C) (~equivalent to the rated cooling capacity at 95°F [35°C]). Therefore, a single-speed heat pump, typically sized to match the building design cooling load, cannot provide adequate heating capacity to match the building heating load at low ambient temperatures. The capacity deficit is filled by inefficient resistance heat, thus lowering the system efficiency and significantly increasing power demand. 3. Cyclic loss is significant if sized to meet the building design heating load—If a single-speed heat pump is sized to meet the heating load, it will be significantly oversized relative to the cooling load in many cold climates. This will cause excessive on/off cyclic loss during the cooling and heating operations at moderately low ambient temperatures. Thus, capacity modulation capability (e.g., using a variable-speed or multi-stage compressor) is necessary for a CCHP, which uses its full capacity to meet the peak heating load and partial capacity to meet the cooling and part-load heating loads. 4. Coefficient of performance (COP) is low—Heating COP degrades significantly at low ambient temperatures owing to the large temperature difference between the heat source and sink. A target CCHP should be sized to meet the building design heating load while minimizing the cyclic loss for the cooling and heating operations at moderate ambient temperatures.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Long-term trends in connected thermostat performance

Internet-connected thermostats (CTs) control heating and cooling systems in about 30% of North American homes, and capture half of annual thermostat sales. In 2017 the U.S. Environmental Protection Agency created a program to certify the performance of ENERGY STAR® Connected Thermostats. To demonstrate compliance with energy-saving criteria, thermostat vendors must submit performance summaries for a representative sample of up to 1250 homes. Vendors must then re-submit results from a new, representative sample every six months in order to maintain their ENERGY STAR certification. This procedure has created a unique record of each thermostat’s long-term performance in response to changes in weather, customer demographics, building stock, and algorithms. Our analysis covers submissions from 13 different vendors, who submitted data up to 7 times over four years. We found that these semi-annual samples generated relatively stable trends for comfort temperatures and Heating, Ventilating and Air Conditioning (HVAC) runtimes over the study period. However, some vendors achieved consistently more energy-conserving comfort temperatures and shorter HVAC runtimes than others. The most recent submission runtimes averaged 700 hours for heating and 1,300 hours for cooling, but some vendors achieved runtimes as much as 17% below the mean. This implies lower energy consumption is due in large part to more successful algorithms and control strategies used by those vendors.

Meier, Alan↗

High Temperature Ceramic Heat Exchangers for the Gen3 Concentrated Solar Power Systems

As part of the Department of Energy’s Solar Energy Technology Office (SETO), the Concentrated Solar Power (CSP) Gen3 Demonstration Roadmap outlined the various technology pathways, goals, and technology needs/gaps to integrate CSP to a supercritical CO 2 (sCO 2 ) power cycle that operates at temperatures >700 °C. It is envisioned that the higher temperature power cycle will enhance the overall system efficiencies and reduce the levelized cost of electricity (LCOE) to meet a 2030 cost target of $0.05/kWhe for baseload CSP plants with ≥12 hours of storage. In this regard, there is a need for heat exchangers (HXs) that can operate at high sCO 2 pressures and temperatures >700 °C. Since current high-temperature alloys degrade at high temperatures, as part of this project, advanced ceramic materials, HX designs, and low-cost additive manufacturing approaches were developed to fabricate and evaluate the performance of the lab-scale ceramic HX prototypes.

14 SOLAR ENERGY↗

Role of On-Site Generation in Carbon Emissions and Utility Bill Savings under Different Electric Grid Scenarios

Energy-efficient and sustainable technologies are necessary to lower energy and carbon footprints. Many technologies are being pursued to meet the increasing energy demand in buildings. An attractive option is efficient utilization of available energy resources, including renewables, to support current and future building energy needs while targeting grid resiliency, energy, and environmental security at an affordable cost via on-site cogeneration-based approaches. This must include energy-efficient technologies with lower greenhouse gas emissions and optimized cost, performance, and reliability. This paper presents the economic and environmental benefits associated with power technologies such as thermionics and solid oxide fuel cells. Hybrid configurations consisting of heat pumps, power systems, and renewable photovoltaics in cogeneration and trigeneration modes of operation are presented. The role of such technologies in lowering CO2 emissions while improving energy resiliency and serving the needs of underprivileged communities is discussed. The key barriers of affordability and potential solutions for large-scale implementation of these promising technologies are reviewed. Case studies demonstrating the influence of power rating, electrical efficiency, design configuration, carbon dioxide intensity of the grid, and fuel on annual greenhouse gas emissions are presented for residential and commercial buildings.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Geothermal Heat Recovery Complex: Large-Scale, Deep Direct-Use System in a Low-Temperature Sedimentary Basin (Final Report)

A feasibility study of using deep direct-use (DDU) geothermal energy to heat agricultural research facilities (ARFs) was conducted at the University of Illinois at Urbana-Champaign (U of IL) and its similar application to military facilities in the Illinois Basin (ILB). The geothermal energy system (GES) investigated utilizes low-temperature (30–90°C; 90–190°F) geothermal fluid (i.e., brine) from an extraction well that is part of a deep, two-well (doublet) system that extends to the bottom of the ILB. The geothermal reservoir modeled, the Mt. Simon Sandstone (MSS), is about 1,280 m (4,200 feet) deep and 457 m thick (1,500 feet) beneath the U of IL. The DDU GES surface infrastructure includes heat exchangers connected in-parallel to pipelines carrying the geothermal fluid and fresh cold and hot water. Analysis of the GES indicated that the MSS can provide a baseload of 2 MMBtu/hr to heat the ARFs by extracting 954 m³/d (6,000 barrels/day [bbl/d]) of geothermal fluid that has a temperature of 44–46 °C (111–115 °F). In addition to analyzing the levelized cost of heat (LCOH) and life cycle costs, the environmental effects of the DDU GES were evaluated, including reduced greenhouse gas (GHG) emissions and water consumption. Multiple system designs were evaluated and then ranked based on their maximum heating performance, energy efficiency, and cost recovery. This feasibility study identified the key components of the fully-integrated DDU technology that can be implemented, both technically and economically. The results and information from this study provides end-users and policy makers with guidance for additional research on the specific components of DDU technology such that its widespread use can provide an uninterruptible energy source, increase resilience from extreme weather conditions, reduce U.S. dependency on fossil fuels, and reduce greenhouse gas (GHG) emissions. The site-specific part of this study gives U of IL administrators a realistic and pragmatic assessment of the financial resources necessary to add a DDU GES in the MSS to the campus’ energy portfolio.

15 GEOTHERMAL ENERGY↗

Experimental Investigation on Heating Performance of a Cold Climate Thermoelectric-Assisted Heat Pump

To accelerate the electrification of air source heat pumps (ASHPs) in cold climates across the United States, various initiatives have been launched to enhance the effectiveness of ASHPs. One avenue of research involves incorporating thermoelectric (TE) technology into vapor compression refrigeration cycles. This study aims to assess the heating performance of a cold climate ASHP by employing TE modules as a liquid line subcooler. The tested system is a nominal 4.5-ton split heat pump utilizing R410A, equipped with a scroll compressor and an accumulator. An electronic expansion valve was employed for both cooling and heating modes. Two configurations of TE sub-coolers, one utilizing 2 TE bundles and the other 4 TE bundles, were integrated into the liquid line of the tested system. The heating performance of these configurations was evaluated. The results revealed that activating the TE subcooler led to a notable increase in total heat capacity, reaching 1318 W at -15.0 °C and 1164 W at -19.0 °C. The corresponding TE coefficients of performance (COPs) were 1.76 and 1.63, respectively. The activation of the TE sub-cooler resulted in a slight reduction in the overall system COP, with a decrease ranging from -2.6% to -4.2% for these two temperatures. The system COPs were measured at 2.10 and 1.86 for -15.0 °C and -19.0 °C, respectively. This prototype demonstrated a significant augmentation in heating capacity with a minimal sacrifice in COP.

Hu, Yifeng↗

Field Test and Thermal Performance Comparison of a Novel Underground Thermal Battery with a Single U-tube Borehole Heat Exchanger for Geothermal Heat Pump Application

Geothermal Heat Pumps (GHP) are a proven technology to electrify and decarbonize space heating and cooling by utilizing the thermally consistent underground as a heat sink or source. However, the high drilling costs of conventional borehole heat exchangers (BHEs) associated with GHP systems and subsurface heterogeneity have been two major challenges to their widespread adoption. In this paper, we present results from a field-scale pilot of an Underground Thermal Battery (UTB) as a potential alternative to a conventional BHE. To benchmark the UTB performance, a side-by-side field test was conducted to compare the UTB with a conventional BHE installed at the same site. The UTB was installed in a 7.01-meter-deep borehole having a diameter of 0.9 meter, whereas the conventional BHE (with single U-tube loop) is in a borehole with 36.6-meter depth and 0.15-meter diameter. Both are integrated into a GHP system to meet the thermal energy demands of office space at the Illinois Energy Farm on the University of Illinois Urbana-Champaign campus. The system’s performance is compared in terms of heat transfer rate, outlet temperatures, and contributions to the overall thermal power of the GHP system under varying thermal demands and in different heat pump operation modes: heating only, cooling only, and hybrid (alternative, diurnal heating and cooling). Results to date indicate that the UTB delivers a more consistent response under during a time period of varying thermal demands. Its operational performance is better during short-term with higher thermal demands, while the conventional BHE performs better under continuous, long-term thermal demands.

Pokhrel, Sajjan [ORNL] (ORCID:0000000228523749)↗

A hybrid method to evaluate the life cycle climate performance of heat pumps

Heat pumps have a significant impact on the climate, and numerous studies exist discussing the environmental impact of heat pumps quantitatively. Life Cycle Climate Performance (LCCP) is a widely accepted metric and can evaluate the carbon footprint of heat pumps from cradle to grave. LCCP calculation typically requires inputs like annual energy consumption, the material used, refrigerant type, and charge level, which are usually the intermediate or final results from heat pump simulation tools. Thus, a platform linking the heat pump simulation software, local weather conditions, and LCCP evaluation tool can simplify the heat pump design process, especially for complicated systems. This paper presents an LCCP evaluation tool accessing the outputs from the DOE Heat Pump Design Model and the building loads and temperature bin data from AHRI standard 210/240. As for case studies, this paper investigates the LCCP values and life cycle electricity costs (LCEC) of a given cooling-based heat pump with R410A in five typical US cities. In conclusion, this cooling-based heat pump has the highest LCCP value at Chicago and lowest LCCP value at Seattle. In contrast, the heat pump has the highest LCEC at Seattle and the lowest LCEC at Miami. As a future work, a more comprehensive carbon emission and cost analysis of heat pump systems will be conducted through all major cities around the world.

Shen, Bo↗

Site Ambient Temperatures and Operating Schedules for EIC - Utility CW Considerations

The heat dissipated by the EIC accelerator system and components is ultimately removed by the conventional water-cooling systems that will be ultimately dissipated the waste heat to the atmosphere. An estimated 45 MW of heat will be dissipated to water during full beam operation and that will need to be effectively rejected to the atmosphere. Approximately 50% of the heat is required to be rejected to a low temperature heat sink that cannot be achieved by an evaporative cooling tower during summer. To operate during these summer months, a secondary chilled water refrigeration system will be required that would increase the cost of the cooling water system. Further, operating chiller compressor in the summer months will increase the energy consumption of the machine. This analysis is being prepared to evaluate the impact on operating and capital costs on the cooling system for various summer operating schedules while utilizing the most cost-effective scenario of an evaporative cooling system. The technology selection for the various heat sinks is addressed in a separate write-up and are not expected to change the conclusions of this write-up.

43 PARTICLE ACCELERATORS↗

Overview of Wendelstein 7-X high-performance operation

The Wendelstein 7-X (W7-X) stellarator has completed two consecutive experimental campaigns OP 2.2 (Sep.-Dec. 2024) and OP 2.3 (Feb.-May 2025) under a new operational strategy enabling more than one year of uninterrupted device availability. This approach, supported by exceptionally high subsystem reliability, allowed sustained high-efficiency plasma operations with up to 80–100 discharges per day across a broad range of magnetic configurations. Several key technical upgrades-most notably the first operation of a 1.5 MW class steady-state gyrotron, a new steady-state pellet injector, and advanced real-time feedback control systems significantly enhanced heating, fueling, and plasma control capabilities. Together, these improvements enabled major advances in long-pulse performance, high-β operation, and confinement optimization. Long-pulse discharges achieved 1.8 GJ of injected energy under fully detached divertor conditions, while reduced-field scenarios facilitated record volume-averaged β values approaching 3%. High-performance plasmas with centrally peaked density profiles, created via neutral beam injection (NBI) or sustained pellet fueling, demonstrated strongly reduced turbulent transport and stellarator-record fusion triple products. Complementary studies of power exhaust and divertor heat loads revealed the role of scrape-off-layer drift physics in shaping strike-line patterns under attached conditions. Together, the results from OP 2.2 and OP 2.3 significantly expand the operational space of W7-X and strengthen its role as a leading platform for steady-state stellarator research and reactor-relevant plasma scenarios.

Wendelstein 7-X↗

Methods and systems for thermal energy storage and their use in buildings applications

The present disclosure relates to particle-based thermal energy storage (TES) systems employed for the heating and cooling applications for residential and/or commercial buildings. Particle-based TES systems may store thermal energy in the particles during off-peak times (i.e., when electricity demand and/or costs are relatively low) and remove the stored thermal energy for heating or cooling applications for buildings during peak times (i.e., when electricity demand and/or costs are relatively high).

Ma, Zhiwen↗

Analysis of pumped thermal energy storage using particle media integrated with concentrating solar power

Pumped Thermal Energy Storage (PTES) is an electricity storage system that converts electricity into thermal energy which is stored and later transformed back into electricity. Previous work has illustrated that particles have low capital costs and can be operated over a wide range of temperatures. PTES with particle storage achieves higher round-trip efficiency and specific power output than when molten salt thermal energy storage is used. This article explores hybrid systems that combine PTES with Concentrating Solar Power (CSP). Hybrid systems share the majority of components thereby reducing costs compared to two stand-alone devices. In addition, hybrid systems can provide multiple services (such as renewable power generation and electricity storage services). Using particle thermal storage in these hybrid concepts provides freedom in choosing the design conditions, since a wide range of operating temperatures is allowable, therefore making it possible to identify hybrid system designs that have good performance. In this article, two concepts for hybrid PTES-CSP are introduced. Thermodynamic models are developed and these are used to evaluate the performance of two hybrid systems. These models account for turbomachinery efficiency, and approach temperature and pressure loss in heat exchangers, as well as other sources of inefficiency, such as motor-generator losses, and air fan power. The “Solar Top-Up” Concept uses CSP to increase the temperature delivered by the charging heat pump. The discharging system uses a topping gas cycle and a bottoming steam cycle to fully exploit the available energy. Using solar heat to increase the maximum temperature from 750 K to 1100 K increases the round-trip efficiency from 41 % to 62 % and the specific work output from 88 kJ/kg to 301 kJ/kg. The second concept is a “Dual-Mode” device which provides both electricity storage and solar electricity generation with the same set of components. The PTES-mode and CSP-mode performance are optimized at different design values but careful parameter selection leads to good performance of both modes: one design produces PTES round-trip efficiency > 60 %, CSP heat engine efficiency > 40 %, and specific work outputs > 150 kJ/kg (for both cycles), when the particle receiver temperature is > 1200 K and maximum heat pump temperature is 1100 K.

14 SOLAR ENERGY↗

RELAP5-3D modelling of the HTTR-GT/H 2 secondary system and turbomachinery

High Temperature Gas-cooled Reactors (HTGRs) can be used for the cogeneration of electricity and hydrogen. The JAEA-operated High-Temperature engineering Test Reactor (HTTR-GT/H 2 ) is exploring using the reactor for electricity and hydrogen production. Here, a RELAP5-3D model of the HTTR-GT/H 2 secondary system has been developed using design information. The various components and heat exchangers in the secondary system were investigated, modified, and improved where applicable. With these changes made, the model was run, and the results were compared to the design conditions. The results for the sole-power generation mode were shown to fit the design conditions very well. The largest temperature difference was on the order of 7 K, and the largest pressure difference was on the order of 0.05 MPa. The results for the hydrogen cogeneration mode did not fit the design conditions as well as the other case. The largest temperature difference was about 39 K and the largest pressure difference was about 0.27 MPa at the compressor outlet. The larger differences for the hydrogen cogeneration mode are attributed to the various complex components and the flow being split in the secondary loop. A transient reduction in heat removal capability of the secondary system was investigated. Reactor temperatures were predicted to rise as a result. The core reactivity response due to this increase in temperature is investigated and is expected to add negative reactivity to the reactor.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Steam generator model design parameter sensitivity study for small modular reactor system

Here, this study focuses on design parameter sensitivity studies pertaining to several Once-Through Steam Generator (OTSG) model cases both with and without a riser using python and advanced risk assessment and optimization tool, i.e. Risk Analysis Virtual Environment (RAVEN) developed at Idaho National Laboratory (INL), to support a Small Modular Reactor (SMR) system. The presented Steam Generator (SG) python-based model is a mathematical representation of a steam-generating unit for a Pressurized Water Reactor (PWR)-type SMR system, including fluid flow and heat transfer equations, models, and correlations. Design studies involve changing the model’s input design parameters (e.g., temperature, pressure, mass flow rate) to observe the resulting effects on the output of the system, such as the Heat Transfer Coefficient (HTC), Reynolds number, Nusselt number, and heat transfer performance. Sensitivity studies analyze the degree to which system output and/or desired parameters (e.g., HTC or heat transfer performance) are sensitive to changes in the input parameters. By using RAVEN, detailed design parametric sensitivity studies. Six input parameters—namely, the pressure, temperature, and mass flow rate for the inlet of the primary-side (hot fluid) and secondary-side (cold fluid) of the SG—were randomly perturbed via RAVEN’s Monte Carlo Sampler module, using uniform distributions (i.e., ±1%, ±5% and ±10 % relative changes) for 600 samples. The analysis results give valuable insights into SG system performance, and provide justification for further research and development such as optimized sensor placement, design verification, validation, and optimization.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Particle Handling in Particle-Based Pumped Thermal Energy Storage

A particle-based pumped thermal electricity storage system stores high-temperature heat (~1000 degrees C) in low-cost silica sand and generates power through an efficient power cycle. Central to this system is a counterflow direct-contact gas/particle fluidized-bed heat exchanger, which can significantly improve the heat exchange process due to the large heat transfer surface area of particles. To showcase a lab-scale 10- to 20-kWe heat exchange process with particles heating up to 300 degrees C, a comprehensive hydrodynamic analysis of the fluidization condition inside the heat exchanger was conducted. The heat exchanger was designed to target for heat exchange process of 10-20 kW and accommodate an air mass flow rate of 0.3-0.7 kg/s. The fluidization condition was set to maintain stable bubbling fluidization, thereby maximizing the particle-to-air heat transfer. An air distributor was designed to equally distribute air over the bed, which can avoid defluidized zones in the heat exchanger. Additionally, particle handling systems including L-valves, screw conveyors, and pneumatic conveyors were developed for the prototype heat exchanger, efficiently conveying high-temperature particles at 0.2-0.5 kg/s. This work lays the foundation for scaling up the system and integrating it into larger energy storage applications, demonstrating its potential for efficient, high-temperature thermal energy storage and power generation.

25 ENERGY STORAGE↗

Impurity Levels in Cerium Oxide Microspheres Prepared by Internal Gelation Sol-Gel Methods

Impurity levels were measured in cerium oxide microspheres fabricated by modified internal gelation sol-gel methods. A combination of glow discharge mass spectrometry, electron impact mass spectrometry, combustion gas analysis and instrumental gas analysis were used to assess a wide range of potential elemental impurities. Low concentrations of carbon, nitrogen, and hydrogen impurities in microspheres showed a dependence on how microspheres were washed. Silicon impurities are believed to derive from silicone oil used during sol-gel processing. Spheres washed by the preferred approach had impurity levels below 100 ppm for all elements tested. For applications such as nuclear fuels, sol-gel methods could meet purity specifications as long as metal nitrate feed solutions of sufficient purity are used and microspheres are washed appropriately. In this study, cerium was used as a surrogate for plutonium-238, which is used in radioisotope power systems as a heat source, to determine whether carbon or other impurities were concentrated during internal gelation processing and remained after heat treatments. Analyses indicated low concentrations of impurities in cerium oxide microspheres after sintering steps that were well below documented limits for plutonium-238 oxide fuels. Modified washing methods, combined with a pressurized water treatment, resulted in sintered cerium oxide sol-gel microspheres with low impurity levels.

cerium oxide, sol-gel, internal gelation, microsph↗