Analysis of the Variable Pressure Growth Chamber using the CASE/A simulation package

A computer simulation of the Variable Pressure Growth Chamber (VPGC), located at the NASA Johnson Space Center, has been developed using the Computer Aided Systems Engineering and Analysis (CASE/A) package. The model has been used to perform several analyses of the VPGC. The analyses consisted of a study of the effects of a human metabolic load on the VPGC and a study of two new configurations for the temperature and humidity control (THC) subsystem in the VPGC. The objective of the human load analysis was to study the effects of a human metabolic load on the air revitalization and THC subsystems. This included the effects on the quantity of carbon dioxide injected and oxygen removed from the chamber and the effects of the additional sensible and latent heat loads. The objective of the configuration analysis was to compare the two new THC configurations against the current THC configuration to determine which had the best performance.

Mcfadden, Carl D.↗

Design and Testing of an Active Heat Rejection Radiator with Digital Turn-Down Capability

NASA's proposed lunar lander, Altair, will be exposed to vastly different external environment temperatures. The challenges to the active thermal control system (ATCS) are compounded by unfavorable transients in the internal waste heat dissipation profile: the lowest heat load occurs in the coldest environment while peak loads coincide with the warmest environment. The current baseline for this fluid is a 50/50 inhibited propylene glycol/water mixture with a freeze temperature around -35 C. While the overall size of the radiator's heat rejection area is dictated by the worst case hot scenario, a turn-down feature is necessary to tolerate the worst case cold scenario. A radiator with digital turn-down capability is being designed as a robust means to maintain cabin environment and equipment temperatures while minimizing mass and power consumption. It utilizes active valving to isolate and render ineffective any number of parallel flow tubes which span across the ATCS radiator. Several options were assessed in a trade-study to accommodate flow tube isolation and how to deal with the stagnant fluid that would otherwise remain in the tube. Bread-board environmental tests were conducted for options to drain the fluid from a turned-down leg as well an option to allow a leg to freeze/thaw. Each drain option involved a positive displacement gear pump with different methods of providing a pressure head to feed it. Test results showed that a start-up heater used to generate vapor at the tube inlet held the most promise for tube evacuation. Based on these test results and conclusions drawn from the trade-study, a full-scale radiator design is being worked for the Altair mission profile.

Sunada, Eric↗

Analyzing at-scale distribution grid response to extreme temperatures

Threats against power grids continue to increase, as extreme weather conditions and natural disasters (extreme events) become more frequent. Hence, there is a need for the simulation and modeling of power grids to reflect realistic conditions during extreme events conditions, especially distribution systems. Herein, this paper presents a modeling and simulation platform for electric distribution grids which can estimate overall power demand during extreme weather conditions. The presented platform's efficacy is shown by demonstrating estimation of electrical demand for 1) Electricity Reliability Council of Texas (ERCOT) during winter storm Uri in 2021, and 2) alternative hypothetical scenarios of integrating Distributed Energy Resources (DERs), weatherization, and load electrification. In comparing to the actual demand served by ERCOT during the winter storm Uri of 2021, the proposed platform estimates approximately 34 GW of peak capacity deficit. These numbers are consistent with state-of-the-art prediction results published in the literature. For the case of the future electrification of heating loads, peak capacity of 78 GW (124% increase) is estimated, which would be reduced to 47 GW (38% increase) with the adoption of efficient heating appliances and improved thermal insulation. Integrating distributed solar PV and storage into the grid causes improvement in the local energy utilization and hence reduces the potential unmet energy by 31% and 40%, respectively.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Mitigation of divertor heat flux by high-frequency ELM pacing with non-fuel pellet injection in DIII-D

Experiments have been conducted on DIII-D investigating high repetition rate injection of non-fuel pellets as a tool for pacing Edge Localized Modes (ELMs) and mitigating their transient divertor heat loads. Effective ELM pacing was obtained with injection of Li granules in different H-mode scenarios, at frequencies 3–5 times larger than the natural ELM frequency, with subsequent reduction of strike-point heat flux. However, in scenarios with high pedestal density (~6 × 10 19 m –3 ), the magnitude of granule triggered ELMs shows a broad distribution, in terms of stored energy loss and peak heat flux, challenging the effectiveness of ELM mitigation. Furthermore, transient heat-flux deposition correlated with granule injections was observed far from the strike-points. As a result, field line tracing suggest this phenomenon to be consistent with particle loss into the mid-plane far scrape-off layer, at toroidal location of the granule injection.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Solar heating and hot water system installed at Southeast of Saline, Unified School District 306, Mentor, Kansas

The solar system, installed in a new building, was designed to provide 52 percent of the estimated annual space heating load and 84 percent of the estimated annual potable hot water requirement. The liquid flat plate collectors are ground-mounted and cover a total area of 5125 square feet. The system will provide supplemental heat for the school's closed-loop water-to-air heat pump system and domestic hot water. The storage medium is water inside steel tanks with a capacity of 11,828 gallons for space heating and 1,600 gallons for domestic hot water. The solar heating facility is described and drawings are presented of the completed system which was declared operational in September 1978, and has functioned successfully since.

Source record↗

Solar heating and cooling demonstration project at the Florida solar energy center

The retrofitted solar heating and cooling system installed at the Florida Solar Energy Center is described. The system was designed to supply approximately 70 percent of the annual cooling and 100 percent of the heating load. The project provides unique high temperature, nonimaging, nontracking, evacuated tube collectors. The design of the system was kept simple and employs five hydronic loops. They are energy collection, chilled water production, space cooling, space heating and energy rejection. Information is provided on the system's acceptance test results operation, controls, hardware and installation, including detailed drawings.

Source record↗

A review of the NASA/OAST cryogenic coolers technology program

Low and ultra low temperature cryogenic cooler systems for future space missions include mechanical, solid cryogen, gas adsorption, superfluid helium, helium-3, and magnetic (adiabatic demagnetization) coolers. Operating lifetimes required vary from a few weeks for a Shuttle/Spacelab mission to as long as nine years for missions to the outer planets. Temperature requirements vary from tens to tenths of kelvin. At the higher temperature, cooling loads for detectors, instruments and associated shields may be as high as 15 watts. The general requirements for low and ultra low temperature and techniques that can be employed to achieve these temperatures at expected heat loads are discussed. The NASA Centers involved in the R & T efforts and the type of cooler systems on which they are focusing their effort are considered as well as the thrust of R & T effort for each cooler type. Projected missions that will use the technology are identified.

Lundholm, J. G., Jr.↗

Thermal Protection System to Enable Ice Giant Aerocapture Mission for Delivering both an Orbiter and an in situ Probe

Ice Giant Missions launched in the next decade can have significantly reduced trip times by incorporating aerocapture as the primary method for orbit insertion instead of conventional propulsive techniques. Furthermore, a mass-efficient aerocapture system for a Neptune mission also enables the delivery of an orbiter, an atmospheric probe for in situ measurements to anchor global data collected by the orbiter, and possibly a lander at Triton. Aerocapture requires a Thermal Protection System (TPS) for the atmospheric entry, and it needs to be robust and mass efficient due to the size of the aeroshell required and the large heat load. Currently there are capable ablative thermal protection materials available, e.g., HEEET (Heatshield for Extreme Entry Environments Technology) and PICA (Phenolic-Impregnated Carbon Ablator) family. In this white paper, we show that the heat-shield TPS mass fraction can be as low as 5% to as high as 20% depending on total trip time reduction and other parameters. Further mass savings in the thermal protection system can be achieved with the use of conformal PICA, either standalone or in combination with HEEET with detailed design. We advocate the mission designers to consider aerocapture for Ice Giant missions so the science community can confidently consider missions to the Ice Giants to achieve unparalleled science in the coming decade.

E Venkatapathy↗

Status of the ESS cryogenic system

The European Spallation Source (ESS) is a neutron science facility funded by a collaboration of 17 European countries currently under design and construction in Lund, Sweden. The centerpiece of ESS is a 2.5 GeV proton linac utilizing superconducting RF cavities operating at 2 K. In addition to cooling the SRF cavities, cryogenics is also used at ESS in the liquid hydrogen moderators surrounding the target. ESS also uses both liquid helium and liquid nitrogen in a number of the planned neutron instruments. There is also a significant cryogenic installation associated with the site acceptance testing of the ESS cryomodules. The ESS cryogenic system consists of 3 separate helium refrigeration/liquefaction plants supplying the accelerator, target moderators and instruments. An extensive cryogenic distribution system connects the accelerator cryoplant with the cryomodules. This paper describes the preliminary design of the ESS cryogenic system including the expected heat loads. Challenges associated with the required high reliability and turn-down capability will also be discussed. A unique feature of ESS is its commitment to sustainability and energy recovery. A conceptual design for recovering waste heat from the helium compressors for use in the Lund district heating system will also be described.

43 PARTICLE ACCELERATORS↗

Hypersonic aerodynamics and entry-maneuver: Aerothermodynamic interactions for two lifting entry vehicles

The longitudinal, directional, and lateral static stability and control characteristics of a delta lifting body and a delta-wing body were obtained at a Mach number of 20 in helium for operational Reynolds numbers over an angle-of-attack range of -4 deg to 55 deg. The aerodynamic characteristics of the wing body were then evaluated in an entry study to examine the effects of vehicle performance on the aerothermodynamic parameters associated with constant and variable angle-of-attack modes for a 1500-n. mi. cross range. The experimental results indicated that the vehicles were stable, except for neutral directional stability for the wing-body shape, and could be trimmed over the operational angle-of-attack range; however, the wing-body vehicle had adverse yaw due to roll control. This roll-yaw coupling was not examined for the lifting body. The trajectory analysis indicated that a 17-percent decrease in performance required little change in the constant angle-of-attack entry mode and, in turn, resulted in a small decrease in the total heat load. For the pitch-modulated entry, the performance decrease required the pitch maneuver to begin earlier during entry and to last longer in order to meet the 1500-n. mi. cross range without a major heating penalty. The performance reduction also had little effect on the maximum laminar radiation equilibrium temperature over a major portion of the lower surface of the wing-body vehicle regardless of the entry mode.

Arrington, J. P.↗

Solar energy system performance evaluation. Seasonal report for Colt Pueblo, Pueblo, Colorado

The Colt-Pueblo solar energy system, designed to provide space heating and hot water preheating, is described and its operational performance for a 12 month period from February 1979 through January 1980 is evaluated. The space heating subsystem met 31 percent of the measured space heating load which was close to the expected 34 percent solar fraction. Although the hot water solar fraction was 79 percent, the overall energy saving capability was reduced because of the low hot water demand. The measured heating subsystem performance would have improved considerably if the uncontrolled losses primarily from transport piping could have been reduced to an inconsequential level. Fossil energy savings of 70.31 million BTUs are estimated.

Source record↗

High-Field Combined-Function Magnets for a 1.5 x 1.5 TeV Muon Collider Storage Ring

Designs and parameters of dipoles and combined-function quadrupoles for bending arc lattice of a 1.5x1.5 TeV muon collider with an average luminosity of 4x1034 cm{sup -2}s{sup -1} are presented. The magnets use the Nb{sub 3}Sn superconductor and provide the required gradients and fields with the appropriate operating margins and field quality. The magnet apertures accommodate tungsten liners to minimize the dynamic heat load in the superconducting coils.

43 PARTICLE ACCELERATORS↗

Thermal Analysis of Thermal Shield for PIP-II SSR1 Cryomodule

Fermilab's PIP-II project plans to enhance the onsite accelerator into the world's most intense neutrino beam, bringing Fermilab into the next generation of particle accelerators. The five different types of cryomodules are vital parts of the PIP-II project and each requires numerous engineering analyses to prove operation. For example, the thermal shield of the Single Spoke Resonator-1 (SSR1) cryomodule required a thermal analysis to ensure the design was operating as intended before fabrication commenced. The thermal shield is cooled by the supercritical helium inside of the extrusion and must remain between 45 and 80 Kelvin. The main purpose of the thermal shield is to intercept different high heat loads and thermal radiation and prevent them from reaching the more sensitive internal components. Finite Element Analysis (FEM) was used to determine temperature estimates of the thermal shield based on the location of a variety of heat sources. Results determined temperatures exceeding the design limit around the crucial component of the current leads. Due to superconducting properties, the areas around the current leads cannot surpass 68 Kelvin. Different solutions to the critical high-temperature areas will be proposed. These solutions range from changing the properties of the helium flow to designing an attachment for the thermal shield. Each proposition works as a viable solution, however, each proposition also has its own set of advantages and disadvantages that are described for further design consideration.

43 PARTICLE ACCELERATORS↗

Space Shuttle Main Engine nozzle thermal protection system

Two of the three Space Shuttle Main Engine (SSME) nozzles are exposed to significant reentry aeroheating loads. To ensure reusability of the Nozzle Assembly, the nozzle primary structure must not exceed specific temperature limits. Due to the thermal, pressure, and dynamic flexing of the nozzle during a mission cycle, an appropriate insulating system must have significant flexibility. Recent missions have demonstrated nozzle reentry aeroheating rates and heat loads much higher than predictions, higher than the capability of the original insulating system. A new insulating system has been developed using similar materials in an aerodynamically 'smooth' shape to both reduce the incoming heating and increase radiation cooling.

Nordlund, R. M.↗

DIII-D accomplishments and plans in support of fusion next steps

DIII-D is using its flexibility and diagnostics to address the critical science required to enable next step fusion devices. We have adapted operating scenarios for ITER to low torque and are now being optimized for transport. Three ELM mitigation scenarios have been developed to near-ITER parameters. New control techniques are managing the most challenging plasma instabilities. Disruption mitigation tools show promising dissipation strategies for runaway electrons and heat load. An off axis neutral beam upgrade has enabled sustainment of high βN capable steady state regimes. Divertor research is identifying the challenge, physics and candidate solutions for handling the hot plasma exhaust with notable progress in heat flux reduction using the snowflake configuration. Our work is helping optimize design choices and prepare the scientific tools for operation in ITER, and resolve key elements of the plasma configuration and divertor solution for an FNSF.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Study of active cooling for supersonic transports

The potential benefits of using the fuel heat sink of hydrogen fueled supersonic transports for cooling large portions of the aircraft wing and fuselage are examined. The heat transfer would be accomplished by using an intermediate fluid such as an ethylene glycol-water solution. Some of the advantages of the system are: (1) reduced costs by using aluminum in place of titanium, (2) reduced cabin heat loads, and (3) more favorable environmental conditions for the aircraft systems. A liquid hydrogen fueled, Mach 2.7 supersonic transport aircraft design was used for the reference uncooled vehicle. The cooled aircraft designs were analyzed to determine their heat sink capability, the extent and location of feasible cooled surfaces, and the coolant passage size and spacing.

Brewer, G. D.↗

TRANSIENT HEAT TRANSFER ANALYSIS FOR SRS RADIOACTIVE TANK OPERATION

The primary objective of the present work is to perform a heat balance study for type-I waste tank to assess the impact of using submersible mixer pumps during waste removal. The temperature results calculated by the model will be used to evaluate the temperatures of the slurry waste under various tank operating conditions. A parametric approach was taken to develop a transient model for the heat balance study for type-I waste tanks such as Tank 11, during waste removal by SMP. The tank domain used in the present model consists of two SMP's for sludge mixing, one STP for the waste removal, cooling coil system with 36 coils, and purge gas system. The sludge waste contained in Tank 11 also has a decay heat load of about 43 W/m{sup 3} mainly due to the emission of radioactive gamma rays. All governing equations were established by an overall energy balance for the tank domain, and they were numerically solved. A transient heat balance model used single waste temperature model, which represents one temperature for the entire waste liquid domain contained in the tank at each transient time.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Use of arc-jet hypersonic blunted wedge flows for evaluating performance of Orbiter TPS

Arc-jet tests at NASA/JSC have been conducted recently to evaluate the performance of the Orbiter Thermal Protection System (TPS) on three critical areas of the side and top of the Orbiter fuselage: (1) cargo bay door, (2) crew access door, and (3) LRSI/FRSI joint regions. Test articles corresponding to these three areas on the Orbiter were mounted in an arc-jet test chamber in a blunted-wedge holder and exposed to hypersonic flow at various angles of attack. The effects of flow direction, heating load, and overtemperature were investigated. In addition, the reuse capability of the TPS materials was evaluated, along with the protection of the pressure seals within the test articles. Thermal match model predictions correlated well with primary structure thermocouple data. Heating rate and pressure predictions based on a nonequilibrium flow field computer program showed good agreement with arc-jet test data and existing hypersonic flow theories.

Rochelle, W. C.↗