Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “frequency selection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 865 records · Page 48

On the detectability of strong lensing in near-infrared surveys

We present new lensing frequency estimates for existing and forthcoming deep near-infrared surveys, including those from JWST and VISTA. The estimates are based on the JAdes extragalactic Ultradeep Artificial Realisations (JAGUAR) galaxy catalogue accounting for the full photometry and morphologies for each galaxy. Due to the limited area of the JAGUAR simulations, they are less suited to wide-area surveys; however, we also present extrapolations to the surveys carried out by Euclid and the Nancy Grace Roman Space Telescope. The methodology does not make assumptions about the nature of the lens itself and probes a wide range of lens masses. The lenses and sources are selected from the same catalogue and extend the analysis from the visible bands into the near-infrared. After generating realistic simulated lensed sources and selecting those that are detectable with SNR > 20, we verify the lensing frequency expectations against published lens samples selected in the visible, finding them to be broadly consistent. We find that JWST could yield ~65 lensed systems in COSMOS-Web, of which ~25 per cent have source redshifts >4. Deeper, narrower programs (e.g. JADES-Medium) will probe more typical source galaxies (in flux and mass) but will find fewer systems (~25). Of the surveys we investigate, we find 55–80 per cent have detectable multiple imaging. Forthcoming NIR surveys will likely reveal new and diverse strong lens systems including lensed sources that are at higher redshift (JWST) and dustier, more massive and older (Euclid NISP) than those typically detected in the corresponding visible surveys.

79 ASTRONOMY AND ASTROPHYSICS↗

Enhancement of Second-Order Nonlinear-Optical Signals by Optical Stimulation

Second-order nonlinear optical interactions such as sum- and difference-frequency generation are widely used for bioimaging and as selective probes of interfacial environments. However, inefficient nonlinear optical conversion often leads to poor signal-to-noise ratio and long signal acquisition times. We demonstrate the dramatic enhancement of weak second-order nonlinear optical signals via stimulated sum- and difference-frequency generation. We present a conceptual framework to quantitatively describe the interaction and show that the process is highly sensitive to the relative optical phase of the stimulating field. To emphasize the utility of the technique, we demonstrate stimulated enhancement of second harmonic generation (SHG) from bovine collagen-I fibrils. Using a stimulating pulse fluence of only $3\text{ }\text{ }\mathrm{nJ}/{\mathrm{cm}}^{2}$, we obtain an SHG enhancement >${10}^{4}$ relative to the spontaneous signal. The stimulation enhancement is greatest in situations where spontaneous signals are the weakest—such as low laser power, small sample volume, and weak nonlinear susceptibility—emphasizing the potential for this technique to improve signal-to-noise ratios in biological imaging and interfacial spectroscopy.

42 ENGINEERING↗

Time and Frequency-Domain Cross-Verification of SLS 6DOF Trajectory Simulations

The SLS GNC team and its partners have developed several time- and frequency-based simulations for development and analysis of the proposed SLS launch vehicle. The simulations differ in fidelity and some have unique functionality that allows them to perform specific analyses. Some examples of the purposes of the various models are: trajectory simulation, multi-body separation, Monte Carlo, hardware in the loop, loads, and frequency domain stability analyses. While no two simulations are identical, many of the models are essentially six degree-of-freedom (6DOF) representations of the SLS plant dynamics, hardware implementation, and flight software. Thus at a high level all of those models should be in agreement. Comparison of outputs from several SLS trajectory and stability analysis tools are ongoing as part of the program's current verification effort. The purpose of these comparisons is to highlight modeling and analysis differences, verify simulation data sources, identify inconsistencies and minor errors, and ultimately to verify output data as being a good representation of the vehicle and subsystem dynamics. This paper will show selected verification work in both the time and frequency domain from the current design analysis cycle of the SLS for several of the design and analysis simulations. In the time domain, the tools that will be compared are MAVERIC, CLVTOPS, SAVANT, STARS, ARTEMIS, and POST 2. For the frequency domain analysis, the tools to be compared are FRACTAL, SAVANT, and STARS. The paper will include discussion of these tools including their capabilities, configurations, and the uses to which they are put in the SLS program. Determination of the criteria by which the simulations are compared (matching criteria) requires thoughtful consideration, and there are several pitfalls that may occur that can severely punish a simulation if not considered carefully. The paper will discuss these considerations and will present a framework for responding to these issues when they arise. For example, small event timing differences can lead to large differences in mass properties if the criteria are to measure those properties at the same time, or large differences in altitude if the criteria are to measure those properties when the simulation experiences a staging event. Similarly, a tiny difference in phase can lead to large gain margin differences for frequency-domain comparisons of gain margins.

VanZwieten, Tannen↗

Time and Frequency-Domain Cross-Verification of SLS 6DOF Trajectory Simulations

The Space Launch System (SLS) Guidance, Navigation, and Control (GNC) team and its partners have developed several time- and frequency-based simulations for development and analysis of the proposed SLS launch vehicle. The simulations differ in fidelity and some have unique functionality that allows them to perform specific analyses. Some examples of the purposes of the various models are: trajectory simulation, multi-body separation, Monte Carlo, hardware in the loop, loads, and frequency domain stability analyses. While no two simulations are identical, many of the models are essentially six degree-of-freedom (6DOF) representations of the SLS plant dynamics, hardware implementation, and flight software. Thus at a high level all of those models should be in agreement. Comparison of outputs from several SLS trajectory and stability analysis tools are ongoing as part of the program's current verification effort. The purpose of these comparisons is to highlight modeling and analysis differences, verify simulation data sources, identify inconsistencies and minor errors, and ultimately to verify output data as being a good representation of the vehicle and subsystem dynamics. This paper will show selected verification work in both the time and frequency domain from the current design analysis cycle of the SLS for several of the design and analysis simulations. In the time domain, the tools that will be compared are MAVERIC, CLVTOPS, SAVANT, STARS, ARTEMIS, and POST 2. For the frequency domain analysis, the tools to be compared are FRACTAL, SAVANT, and STARS. The paper will include discussion of these tools including their capabilities, configurations, and the uses to which they are put in the SLS program. Determination of the criteria by which the simulations are compared (matching criteria) requires thoughtful consideration, and there are several pitfalls that may occur that can severely punish a simulation if not considered carefully. The paper will discuss these considerations and will present a framework for responding to these issues when they arise. For example, small event timing differences can lead to large differences in mass properties if the criteria are to measure those properties at the same time, or large differences in altitude if the criteria are to measure those properties when the simulation experiences a staging event. Similarly, a tiny difference in phase can lead to large gain margin differences for frequency-domain comparisons of gain margins.

Johnson, Matthew↗

Holographic testing of composite propfans for a cruise missile wind tunnel model

Each of the approximately 90 composite propfan blades constructed for a 55 percent scale cruise missile wind tunnel model were holographically tested to obtain natural frequencies and mode shapes. These data were used not only for quality assurance, but also to select sets of similar blades for each blade row. Presented along with the natural frequency data is a description of a computer-based image processing system developed to supplement the photographic based system for holographic image analysis and storage. The new system is quicker and cheaper, the holograms are indexed better, and several engineers can access the data simultaneously. The only negative effect is a slight reduction in image resolution, which does not influence the end use.

Miller, Christopher J.↗

Bubble Measuring Instrument and Method

Method and apparatus are provided for a non-invasive bubble measuring instrument operable for detecting, distinguishing, and counting gaseous embolisms such as bubbles over a selectable range of bubble sizes of interest. A selected measurement volume in which bubbles may be detected is insonified by two distinct frequencies from a pump transducer and an image transducer. respectively. The image transducer frequency is much higher than the pump transducer frequency. The relatively low-frequency pump signal is used to excite bubbles to resonate at a frequency related to their diameter. The image transducer is operated in a pulse-echo mode at a controllable repetition rate that transmits bursts of high-frequency ultrasonic signal to the measurement volume in which bubbles may be detected and then receives the echo. From the echo or received signal, a beat signal related to the repetition rate may be extracted and used to indicate the presence or absence of a resonant bubble. In a preferred embodiment, software control maintains the beat signal at a preselected frequency while varying the pump transducer frequency to excite bubbles of different diameters to resonate depending on the range of bubble diameters selected for investigation.

Kline-Schoder, Robert↗

Bubble Measuring Instrument and Method

Method and apparatus are provided for a non-invasive bubble measuring instrument operable for detecting. distinguishing, and counting gaseous embolisms such as bubbles over a selectable range of bubble sizes of interest. A selected measurement volume in which bubbles may be detected is insonified by two distinct frequencies from a pump transducer and an image transducer, respectively. The image transducer frequency is much higher than the pump transducer frequency. The relatively low-frequency pump signal is used to excite bubbles to resonate at a frequency related to their diameter. The image transducer is operated in a pulse-echo mode at a controllable repetition rate that transmits bursts of high-frequency ultrasonic signal to the measurement volume in which bubbles may be detected and then receive, the echo. From the echo or received signal, a beat signal related to the repetition rate may be extracted and used to indicate the presence or absence of a resonant bubble. In a preferred embodiment, software control maintains the beat signal at a preselected frequency while varying the pump transducer frequency to excite bubbles of different diameters to resonate depending on the range of bubble diameters selected for investigation.

Robert Kline-Schoder↗

Bubble Measuring Instrument and Method

Method and apparatus are provided for a non-invasive bubble measuring instrument operable for detecting, distinguishing, and counting gaseous embolisms such as bubbles over a selectable range of bubble sizes of interest. A selected measurement volume in which bubbles may be detected is insonified by two distinct frequencies from a pump transducer and an image transducer, respectively. The image transducer frequency is much higher than the pump transducer frequency. The relatively low-frequency pump signal is used to excite bubbles to resonate at a frequency related to their diameter. The image transducer is operated in a pulse-echo mode at a controllable repetition rate that transmits bursts of high-frequency ultrasonic signal to the measurement volume in which bubbles may be detected and then receives the echo. From the echo or received signal, a beat signal related to the repetition rate may be extracted and used to indicate the presence or absence of a resonant bubble. In a preferred embodiment, software control maintains the beat signal at a preselected frequency while varying the pump transducer frequency to excite bubbles of different diameters to resonate depending on the range of bubble diameters selected for investigation.

Robert Kline-Schoder↗

Bubble Measuring Instrument and Method

Method and apparatus are provided for a non-invasive bubble measuring instrument operable for detecting, distinguishing, and counting gaseous embolisms such as bubbles over a selectable range of bubble sizes of interest. A selected measurement volume in which bubbles may be detected is insonified by two distinct frequencies from a pump transducer and an image transducer, respectively. The image transducer frequency is much higher than the pump transducer frequency. The relatively low-frequency pump signal is used to excite bubbles to resonate at a frequency related to their diameter. The image transducer is operated in a pulse-echo mode at a controllable repetition rate that transmits bursts of high-frequency ultrasonic signal to the measurement volume in which bubbles may be detected and then receives the echo. From the echo or received signal, a beat signal related to the repetition rate may be extracted and used to indicate the presence or absence of a resonant bubble. In a preferred embodiment, software control maintains the beat signal at a preselected frequency while varying the pump transducer frequency to excite bubbles of different diameters to resonate depending on the range of bubble diameters selected for investigation.

Robert Kline-Schoder↗

Bubble measuring instrument and method

Method and apparatus are provided for a non-invasive bubble measuring instrument operable for detecting, distinguishing, and counting gaseous embolisms such as bubbles over a selectable range of bubble sizes of interest. A selected measurement volume in which bubbles may be detected is insonified by two distinct frequencies from a pump transducer and an image transducer, respectively. The image transducer frequency is much higher than the pump transducer frequency. The relatively low-frequency pump signal is used to excite bubbles to resonate at a frequency related to their diameter. The image transducer is operated in a pulse-echo mode at a controllable repetition rate that transmits bursts of high-frequency ultrasonic signal to the measurement volume in which bubbles may be detected and then receives the echo. From the echo or received signal, a beat signal related to the repetition rate may be extracted and used to indicate the presence or absence of a resonant bubble. In a preferred embodiment, software control maintains the beat signal at a preselected frequency while varying the pump transducer frequency to excite bubbles of different diameters to resonate depending on the range of bubble diameters selected for investigation.

Kline-Schoder, Robert↗

Experimental Study of Isothermal Wake-Flow Characteristics of Various Flame-Holder Shapes

An investigation of the isothermal wake-flow characteristics of several flame-holder shapes was carried out in a 4- by 4-inch flow chamber. The effects of flame-holder-shape changes on the characteristics of the Karman vortices and thus on the recirculation zones to which experimenters have related the combustion process were obtained for several flame holders. The results may furnish a basis of correlation, of combustion efficiency and stability for similarly shaped flame holders in combustion studies. Values of the spacing ratio-(ratio of lateral spacing to longitudinal spacing of vortices] obtained for the various shapes approximated the theoretical value of 0.36 given by the Karman stability analysis. Variations in vortex strength of more than 200 percent and in frequency of more than 60 percent were accomplished by varying flame-holder shape. A maximum increase in the recirculation parameter of 56 percent over that for a conventional V-gutter was also obtained. Varying flameholder shape and size enables the designer to select many schedules of variations in vortex strength and frequency- not obtainable by changing size only and may make it possible to approach theoretical maximum vortex strength for any given frequency.

Younger, G. G.↗

Automatic N(h,t) profiles of the ionosphere with a digital ionosonde

A method is described to accomplish automatic data selection and profile inversion to obtain ionospheric electron density profiles from digitized radio soundings. The profile inversion is based on a well-established formulation by which the optimum radio frequency sounding intervals can be specified from an approximate knowledge of the profile; the expected virtual height coordinates (h) at these frequencies (f) are estimated, and procedures are then used to select h(f) observations nearest the predicted coordinates from a subsequent digital ionogram. From these the next profile is obtained. The process adaptively follows the changing shape and detail of the profile. The procedure requires an average of 15 sec per profile on a standard data processing computer, and can be adapted, with benefit to online real-time use in a digital ionosonde.

Wright, J. W.↗

A study of lunar impact crater size-distributions

In view of the discrepancies in published crater frequency data, effects modifying production size distributions of impact craters are discussed. The resulting criteria are applied to the determination of the size distributions of unmodified impact crater populations in selected lunar regions of different ages. The measured cumulative crater frequencies are used to obtain a general calibration size distribution curve by a normalization procedure. Deviations of measured size distributions from the calibration distribution are strongly suggestive of the existence of processes having modified the primary impact crater population.

Neukum, G.↗

Electrical signal transmission and gap junction regulation in a bone cell network: a cable model for an osteon

A cable model is formulated to estimate the spatial distribution of intracellular electric potential and current, from the cement line to the lumen of an osteon, as the frequency of the loading and the conductance of the gap junction are altered. The model predicts that the characteristic diffusion time for the spread of current along the membrane of the osteocytic processes, 0.03 sec, is nearly the same as the predicted pore pressure relaxation time in Zeng et al. (Annals of Biomedical Engineering. 1994) for the draining of the bone fluid into the osteonal canal. This approximate equality of characteristic times causes the cable to behave as a high-pass, low-pass filter cascade with a maximum in the spectral response for the intracellular potential at approximately 30 Hz. This behavior could be related to the experiments of Rubin and McLeod (Osteoporosis, Academic Press, 1996) which show that live bone appears to be selectively responsive to mechanical loading in a specific frequency range (15-30 Hz) for several species.

NASA Discipline Musculoskeletal↗

Test results for rotordynamic coefficients of anti-swirl self-injection seals

Test results are presented for rotordynamic coefficients and leakage for three annular seals which use anti-swirl self-injection concept to yield significant improvement in whirl frequency ratios as compared to smooth and damper seals. A new anti-swirl self-inection mechanism is achieved by deliberately machining self-injection holes inside the seal stator mechanism which is used to achieve effective reduction of the tangential flow which is considered as a prime cause of rotor instability in high performance turbomachinery. Test results show that the self-injection mechanism significantly improves whirl frequency ratios; however, the leakage performance degrades due to the introduction of the self-injection mechanism. Through a series of the test program, an optimum anti-swirl self-injection seal which uses a labyrinth stator surface with anti-axial flow injections is selected to obtain a significant improvement in the whirl frequency ratio as compared to a damper seal, while showing moderate leakage performance. Best whirl frequency ratio is achieved by an anti-swirl self-injection seal of 12 holes anti-swirl and 6 degree anti-leakage injection with a labyrinth surface configuration. When compared to a damper seal, the optimum configuration outperforms the whirl frequency ratio by a factor of 2.

Kim, C. H.↗

GMRT Low-frequency Imaging of an Extended Sample of X-shaped Radio Galaxies

We present a low-frequency imaging study of an extended sample of X-shaped radio sources using the Giant Metrewave Radio Telescope (GMRT) at two frequencies (610 and 240 MHz). The sources were drawn from a Very Large Array Radio Images of the Sky at Twenty-Centimeters (FIRST) selected sample and extend an initial GMRT study at the same frequencies of 12 X-shaped radio galaxies predominantly from the 3CR catalog (Lal and Rao 2007). Both the intensity maps and spectral index maps of the 16 newly observed sources are presented. With the combined sample of 28 X-shaped radio sources, we found no systematic differences in the spectral properties of the higher surface brightness, active lobes versus the lower surface brightness, or off-axis emission. The properties of the combined sample are discussed, including the possible role of a twin active galactic nuclei model in the formation of such objects.

79 ASTRONOMY AND ASTROPHYSICS↗

The Precipitation Rate Retrieval Algorithms for the GPM Dual-frequency Precipitation Radar

In this paper, precipitation rate retrieval algorithms for the Global Precipitation Measurement mission's Dual-frequency Precipitation Radar (DPR) are developed. The DPR consists of a Ku-band radar (KuPR; 13.6 GHz) and a Ka-band radar (KaPR; 35.5 GHz). For the KuPR, an algorithm similar to the Tropical Rainfall Measuring Mission's Precipitation Radar algorithm is developed, with the relation between precipitation rate R and massweighted mean diameter D m (R−D m relation) replacing the relation between the specific attenuation k and effective radar reflectivity factor Z e . The R−D m relation can also be applied to the KaPR and dual-frequency algorithms. In both the single-frequency and dual-frequency algorithms, the forward retrieval method is applied with an assumed adjustment factor for the R−D m relation (ε) and the results are evaluated to select the best value of ε. The advantages of the dual-frequency algorithm are the availability of the dual-frequency surface reference technique and the ZfKa method, which is a method to use the attenuation-corrected radar reflectivity factor Z f of KaPR, to select ε as well as the possibility to selectively use measurements from KuPR or KaPR. This paper also describes the derivation of the scattering table and the R−D m relation as well as the procedure for non-uniform beam filling correction in detail. The outputs are then statistically analyzed to demonstrate algorithm performance.

precipitation radar↗

Trends in Formic Acid Decomposition on Model Transition Metal Surfaces: A Density Functional Theory Study

We present a first-principles, self-consistent periodic density functional theory (PW91-GGA) study of formic acid (HCOOH) decomposition on model (111) and (100) facets of eight fcc metals (Au, Ag, Cu, Pt, Pd, Ni, Ir, and Rh) and (0001) facets of four hcp (Co, Os, Ru, and Re) metals. The calculated binding energies of key formic acid decomposition intermediates including formate (HCOO), carboxyl (COOH), carbon monoxide (CO), water (H2O), carbon dioxide (CO2), hydroxyl (OH), carbon (C), oxygen (O), and hydrogen (H; H2) are presented. Using these energetics, we develop thermochemical potential energy diagrams for both the carboxyl-mediated and the formate-mediated dehydrogenation mechanisms on each surface. We evaluate the relative stability of COOH, HCOO, and other isomeric intermediates (i.e., CO + OH, CO2 + H, CO + O + H) on these surfaces. These results provide insights into formic acid decomposition selectivity (dehydrogenation versus dehydration), and in conjunction with calculated vibrational frequency modes, the results can assist with the experimental search for the elusive carboxyl (COOH) surface intermediate. Results are compared against experimental reports in the literature.

Environmental Molecular Sciences Laboratory↗