Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “frequency range”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 865 records · Page 48

Compact carbon monoxide sensor utilizing a confocal optical cavity.

The carbon monoxide sensor discussed in this paper utilizes a unique confocal cavity which allows the complete system to be packaged in a small volume suitable for hand-held use. The optical system is the heart of the instrument with equal emphasis placed on the electronics support circuitry, consisting essentially of a thermal infrared pyroelectric detector and lock-in amplifier. The pyroelectric detector offers a major advantage over other thermal detectors, providing a signal-to-noise ratio and detectivity that remain nearly constant over the frequency range from dc to 2000 Hz. Since bias voltage is not required, low frequency noise is not generated in the detector.

Scott, B.↗

Field measurement of penetrator seismic coupling in sediments and volcanic rocks

Field experiments were conducted to determine experimentally how well a seismometer installed using a penetrator would be coupled to the ground. A dry lake bed and a lava bed were chosen as test sites to represent geological environments of two widely different material properties. At each site, two half-scale penetrators were fired into the ground, a three-component geophone assembly was mounted to the aft end of each penetrator, and dummy penetrators were fired at various distances to generate seismic signals. The recorded signals were digitized, and cross-spectral analyses were performed to compare the observed signals in terms of power spectral density ratio, coherence and phase difference. The analyses indicate that seismometers deployed by penetrators will be as well coupled to the ground as are seismometers installed by conventional methods for the frequency range of interest in earthquake seismology, although some minor differences were observed at frequencies near the upper limit of the frequency band.

Nakamura, Y.↗

Snow Electromagnetic Measurements

An electromagnetic system is described for measuring the dielectric constant and attenuation of snow samples in the frequency range of 4 to 12 GHz. System components consists of a swept-frequency source, microwave horns, network analyzer, and XY plotter. The procedure for calibrating the effect of wetness on the snow properties is described. Equations are given that express the experimentally determined relation between attenuation per unit length and volume percent wetness at any frequency between 4 and 12 GHz. permittivity can be calculated from the snow density, attenuation per unit length, and frequency. Some applications of the techniques are described such as runoff forecasting from mountain snowpacks.

Linlor, W. I.↗

Seismic codas on the earth and the moon - A comparison

The seismic codas, representing that part of the seismogram following the arrival of the surface waves or the direct S waves, characteristic of the earth and moon are compared with regard to the implications of coda characteristics for scattering and attenuation. Scattering models based on single S-S scatter theory, in which seismic energy in the coda is assumed to be S waves that have undergone only one scattering without conversion, and on diffusion theory, which assumed that energy in the coda has been scattered many times, are examined, and situations where the single-scattering and multiple-scattering theories are applicable are distinguished by the ratio of attenuation distance to the scattering mean free path. Values of the attenuation distance and the mean free path derived from coda studies for the earth and moon are compared, and it is found that for the frequency range 0.5-10 Hz, diffusion scattering is important in lunar codas, while at frequencies from 1 to 25 Hz single scattering is important in terrestrial codas. It is pointed out that attenuation acts to eliminate scattering paths much longer than the attenuation length. The observed differences between terrestrial and lunar codas are thus attributed to lesser attenuation and greater scattering on the moon.

Dainty, A. M.↗

Detection of a radio emission at 3 kHz in the outer heliosphere

A radio source in the outer heliosphere has been detected by the plasma wave receivers on Voyagers 1 and 2. The radio emission is observed in the frequency range 2-3 kHz, and is above the local solar wind electron plasma frequency whenever supporting plasma density data are available. The maximum spectral density of the emission recorded is about 10 to the -14th V-squared/m-squared/Hz. The bandwidth of the radio noise is about 1 kHz. Possible sources include continuum radiation from Jupiter's distant magnetotail and radiation at the second harmonic of the plasma frequency at the heliopause. If the latter interpretation is correct, these data represent the first remote observations of the heliopause.

Kurth, W. S.↗

Narrow-band Electrostatic Noise generated by an electron velocity space hole

Narrow-band Electrostatic Noise (NEN) is a common occurrence in the Earth's distant magnetotail. NEN is observed in a frequency range (100-316 Hz) that falls roughly between the electron and ion plasma frequencies. This mode may result from holes in the electron distribution function associated with slow shocks. An instability that is associated with this mode is studied using numerical simulations. The growth of the instability depends on the size and shape of the hole. The hole mode can also be driven unstable by either an anisotropy in the electron distribution function or an ion beam. In all these cases the instability saturates at a low level and only a fraction of the available free energy is released.

Richard, Robert L.↗

Double-Edge Molecular Technique for Doppler Lidar Wind Measurement

The double-edge lidar technique for measuring the wind using molecular backscatter is described. Two high spectral resolution edge filters are located in the wings of the Rayleigh-Brillouin profile. This doubles the signal change per unit Doppler shift, the sensitivity, and gives nearly a factor of two improvement in measurement accuracy. The use of a crossover region is described where the sensitivity of a molecular and aerosol-based measurement are equal. This desensitizes the molecular measurement to the effects of aerosol scattering over a frequency range of +/- 100 m/s. We give methods for correcting for short-term frequency jitter and drift using a laser reference frequency measurement and methods for long-term frequency correction using a servo control system. The effects of Rayleigh-Brillouin scattering on the measurement are shown to be significant and are included in the analysis. Simulations for a conical scanning satellite-based lidar at 355 nm show an accuracy of 2-3 m/s for altitudes of 2 to 15 km for a 1 km vertical resolution, a satellite altitude of 400 km and a 200 km x 200 km spatial resolution. Results of ground based wind measurements are presented.

Flesia, Cristina↗

Response properties of pigeon otolith afferents to linear acceleration

In the present study, the sensitivity to sinusoidal linear accelerations in the plane of the utricular macula was tested in afferents. The head orientation relative to the translation axis was varied in order to determine the head position that elicited the maximal and minimal responses for each afferent. The response gain and phase values obtained to 0.5-Hz and 2-Hz linear acceleration stimuli were then plotted as a function of head orientation and a modified cosine function was fit to the data. From the best-fit cosine function, the predicted head orientations that would produce the maximal and minimal response gains were estimated. The estimated maximum response gains to linear acceleration in the utricular plane for the afferents varied between 75 and 1420 spikes s-1 g-1. The mean maximal gains for all afferents to 0.5-Hz and 2-Hz sinusoidal linear acceleration stimuli were 282 and 367 spikes s-1 g-1, respectively. The minimal response gains were essentially zero for most units. The response phases always led linear acceleration and remained constant for each afferent, regardless of head orientation. These response characteristics indicate that otolith afferents are cosine tuned and behave as one-dimensional linear accelerometers. The directions of maximal sensitivity to linear acceleration for the afferents varied throughout the plane of the utricle; however, most vectors were directed out of the opposite ear near the interaural axis. The response dynamics of the afferents were tested using stimulus frequencies ranging between 0.25 Hz and 10 Hz (0.1 g peak acceleration). Across stimulus frequencies, most afferents had increasing gains and constant phase values. These dynamic properties for individual afferents were fit with a simple transfer function that included three parameters: a mechanical time constant, a gain constant, and a fractional order distributed adaptation operator.

Non-NASA Center↗

Single Pixel Characterization of X-Ray TES Microcalorimeter Under AC Bias at MHz Frequencies

In this paper we present the progress made at SRON in the read-out of GSFC x-ray transition-edge sensor (TES) micro-calorimeters in the frequency domain. The experiments reported so far, whose aim was to demonstrate an energy resolution of 2eV at 6 keV with a TES acting as a modulator, were carried out at frequencies below 700 kHz using a standard flux locked loop (FLL) SQUID read-out scheme. The TES read-out suffered from the use of sub-optimal circuit components, large parasitic inductances, low quality factor resonators and poor magnetic field shielding. We have developed a novel experimental set-up, which allows us to test several read-out schemes in a single cryogenic run. In this set-up, the TES pixels are coupled via superconducting transformers to 18 high-Q lithographic LC filters with resonant frequencies ranging between 2 and 5 MHz. The signal is amplified by a two-stage SQUID current sensor and baseband feedback is used to overcome the limited SQUID dynamic range. We study the single pixel performance as a function of TES bias frequency, voltage and perpendicular magnetic field.

Gottardi, L.↗

Design of a Variable Thickness Plate to Focus Bending Waves

This paper describes the design of a thin plate whose thickness is tailored in order to focus bending waves to a desired location on the plate. Focusing is achieved by smoothly varying the thickness of the plate to create a type of lens, which focuses structural-borne energy. Damping treatment can then be positioned at the focal point to efficiently dissipate energy with a minimum amount of treatment. Numerical simulations of both bounded and unbounded plates show that the design is effective over a broad frequency range, focusing traveling waves to the same region of the plate regardless of frequency. This paper also quantifies the additional energy dissipated by local damping treatment installed on a variable thickness plate relative to a uniform plate.

Schiller, Noah H.↗

In-flight System Identification of the Ingenuity Mars Helicopter

The 68th and 69th flights of NASA’s Ingenuity Mars Helicopter marked the first dedicated system identification flights of an aerial vehicle on another planet. Chirp signals were injected into the swashplate cyclic controls for both legs of the two out-and-back flights. Frequency responses were computed from the flight data, using both the Direct Method (DM) and the Joint-Input-Output (JIO) approach, for the identification of stability and control derivatives in forward flight conditions. The resulting identified state-space models were compared against existing flight dynamics simulation models, showing excellent correlation in the higher frequency range. External disturbances were seen to introduce a bias in the identified lower frequency responses, which was partially mitigated using the JIO method. These findings will inform future modeling and flight testing efforts of Mars rotorcraft.

Ingenuity↗

Nonlinear nanomechanical oscillators for ultrasensitive inertial detection

A system for ultrasensitive mass and/or force detection of this invention includes a mechanical oscillator driven to oscillate in a nonlinear regime. The mechanical oscillator includes a piezoelectric base with at least one cantilever resonator etched into the piezoelectric base. The cantilever resonator is preferably a nonlinear resonator which is driven to oscillate with a frequency and an amplitude. The system of this invention detects an amplitude collapse of the cantilever resonator at a bifurcation frequency as the cantilever resonator stimulated over a frequency range. As mass and/or force is introduced to the cantilever resonator, the bifurcation frequency shifts along a frequency axis in proportion to the added mass.

47 OTHER INSTRUMENTATION↗

Design, Fabrication, and Characterization of a Piezoelectric AFM Cantilever Array

Atomic force microscope (AFM) is a powerful instrument, which has been successfully employed in a myriad of applications from imaging to lithography, over the last decades. Despite its widespread use, low throughput of the AFM remains one of its major limitations along with slow scan rates in tapping mode. In this work, we propose a microfabricated cantilever array composed of five cantilevers, each equipped with onchip piezoelectric displacement sensors and an actuator for parallel imaging in tapping mode. The cantilevers are designed to have separate resonance frequencies in order to effectively minimize the vibrational coupling. The measured resonance frequencies range from 85.34 kHz to 107.78 kHz, and more than 5 kHz resonant frequency separation is achieved in the neighboring cantilevers. Vibrational coupling is mitigated by over two orders of magnitude compared to arrays with identical cantilevers. The common feedthrough problem in this type of active system is addressed by configuring the displacement sensors differentially. Finally, one of the cantilevers in the arrayis successfully employed for tapping mode AFM imaging.

42 ENGINEERING↗

POWER SPECTRAL DENSITY OF FLUCTUATIONS OF BULK AND THERMAL SPEEDS IN THE SOLAR WIND

This paper analyzes solar wind power spectra of bulk and thermal speed fluctuations that are computed with a time resolution of 32 ms in the frequency range of 0.001–2 Hz. The analysis uses measurements of the Bright Monitor of the Solar Wind on board the Spektr-R spacecraft that are limited to 570 km s{sup 1} bulk speed. The statistics, based on more than 42,000 individual spectra, show that: (1) the spectra of bulk and thermal speeds can be fitted by two power-law segments; (2) despite their large variations, the parameters characterizing frequency spectrum fits computed on each particular time interval are very similar for both quantities; (3) the median slopes of the bulk and thermal speeds of the segment attributed to the MHD scale are 1.43 and 1.38, respectively, whereas they are 3.08 and 2.43 in the kinetic range; (4) the kinetic range slopes of bulk and thermal speed spectra become equal when either the ion density or magnetic field strength are high; (5) the break between MHD and kinetic scales seems to be controlled by the ion β parameter; (6) the best scaling parameter for bulk and thermal speed variations is a sum of the inertial length and proton thermal gyroradius; and (7) the above conclusions can be applied to the density variations if the background magnetic field is very low.

79 ASTRONOMY AND ASTROPHYSICS↗

Conversion of electrostatic plasma waves into electromagnetic waves - Numerical calculation of the dispersion relation for all wavelengths.

The dispersion curves have been computed for a wide range of wavelengths from electromagnetic waves to electrostatic waves in a magnetoactive warm plasma with a Maxwellian velocity distribution function. The computation was carried out mainly for the perpendicular propagation mode. The upper hybrid resonance is the connection point of the electrostatic waves and the electromagnetic waves. The electrostatic waves not associated with the upper hybrid resonance are subjected to electron cyclotron damping when the wavelength becomes long. Oblique propagation is allowed for the electrostatic waves in a frequency range from the plasma frequency to the upper hybrid resonance frequency in the long-wavelength region where Landau damping can be neglected and where the electrostatic mode smoothly connects to the electromagnetic X-mode. In a slightly inhomogeneous plasma, the Bernstein-mode electrostatic wave can escape by being converted into the O-mode electromagnetic wave; two reflections take place during this escape process.

Oya, H.↗

Softening of infrared-active mode of perovskite BaZrO{sub 3} proved by terahertz time-domain spectroscopy

The low-frequency infrared-active optical modes were studied in a barium zirconate, BaZrO{sub 3}, single crystal with the perovskite structure using terahertz (THz) time-domain spectroscopy (TDS). The real and imaginary parts of the dielectric constants were accurately determined in the frequency range between 0.2 and 2.7 THz. Upon cooling from room temperature to 8 K, the lowest-frequency TO1 mode at 2.32 THz showed a pronounced softening to 1.94 THz. The real part of the dielectric constant at 0.5 THz determined by THz-TDS obeys Barrett's relation, and the existence of a plateau confirms that the quantum effects lead to saturation of the soft mode frequencies of the TO1 and TO2 modes below ≈20 K. This is reminiscent of incipient ferroelectrics with the perovskite structure such as CaTiO{sub 3}.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Implementation of the NASA High Intensity Modal Impedance Tube

This paper provides a description of the High Intensity Modal Impedance Tube (HIMIT) and its use for the evaluation of acoustic liners. Tests conducted with two liners, one linear and one nonlinear, are used to evaluate the suitability of the HIMIT for evaluation at frequencies up to 6 kHz and sound pressure levels up to 155 dB. Two impedance eduction methods are used, one suitable for plane wave frequencies and the other applicable over the full frequency range. These educed impedances are compared against those computed with an impedance prediction method and against those educed with another zero-flow test rig. These results confirm that the HIMIT can be used with confidence for the evaluation of acoustic liners over these frequency and sound pressure level ranges.

impedance↗

Electron cyclotron resonance ion source plasma chamber studies using a network analyzer as a loaded cavity probe

A method and first results utilizing a network analyzer as a loaded cavity probe to study the resonance properties of a plasma filled electron cyclotron resonance ion source (ECRIS) plasma chamber are presented. The loaded cavity measurements have been performed using a dual port technique, in which two separate waveguides were used simultaneously. One port was used to ignite and sustain the plasma with a microwave source operating around 11 GHz and the other was used to probe the cavity properties with the network analyzer using a frequency range around 14 GHz. The first results obtained with the JYFL 14 GHz ECRIS demonstrate that the presence of plasma has significant effects on the resonance properties of the cavity. With plasma the frequency dependent behavior is strongly damped and this trend strengthens with increasing microwave power.

43 PARTICLE ACCELERATORS↗