Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “fractionalization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 865 records · Page 48

Single Droplet Combustion of Decane in Microgravity: Experiments and Numerical Modeling

This paper presents experimental data on single droplet combustion of decane in microgravity and compares the results to a numerical model. The primary independent experiment variables are the ambient pressure and oxygen mole fraction, pressure, droplet size (over a relatively small range) and ignition energy. The droplet history (D(sup 2) history) is non-linear with the burning rate constant increasing throughout the test. The average burning rate constant, consistent with classical theory, increased with increasing ambient oxygen mole fraction and was nearly independent of pressure, initial droplet size and ignition energy. The flame typically increased in size initially, and then decreased in size, in response to the shrinking droplet. The flame standoff increased linearly for the majority of the droplet lifetime. The flame surrounding the droplet extinguished at a finite droplet size at lower ambient pressures and an oxygen mole fraction of 0.15. The extinction droplet size increased with decreasing pressure. The model is transient and assumes spherical symmetry, constant thermo-physical properties (specific heat, thermal conductivity and species Lewis number) and single step chemistry. The model includes gas-phase radiative loss and a spherically symmetric, transient liquid phase. The model accurately predicts the droplet and flame histories of the experiments. Good agreement requires that the ignition in the experiment be reasonably approximated in the model and that the model accurately predict the pre-ignition vaporization of the droplet. The model does not accurately predict the dependence of extinction droplet diameter on pressure, a result of the simplified chemistry in the model. The transient flame behavior suggests the potential importance of fuel vapor accumulation. The model results, however, show that the fractional mass consumption rate of fuel in the flame relative to fuel vaporized is close to 1.0 for all but the lowest ambient oxygen mole fractions.

Dietrich, D. L.↗

Interkinetic and migratory behavior of a cohort of neocortical neurons arising in the early embryonic murine cerebral wall

Neocortical neuronogenesis occurs in the pseudostratified ventricular epithelium (PVE) where nuclei of proliferative cells undergo interkinetic nuclear movement. A fraction of daughter cells exits the cell cycle as neurons (the quiescent, or Q, fraction), whereas a complementary fraction remains in the cell cycle (the proliferative, or P, fraction). By means of sequential thymidine and bromodeoxyuridine injections in mouse on embryonic day 14, we have monitored the proliferative and post-mitotic migratory behaviors of 1 and 2 hr cohorts of PVE cells defined by the injection protocols. Soon after mitosis, the Q fraction partitions into a rapidly exiting (up to 50 microns/hr) subpopulation (Qr) and a more slowly exiting (6 microns/hr) subpopulation (Qs). Qr and Qs are separated as two distributions on exit from the ventricular zone with an interpeak distance of approximately 40 microns. Cells in Qr and Qs migrate through the intermediate zone with no significant change in the interpeak distance, suggesting that they migrate at approximately the same velocities. The rate of migration increases with ascent through the intermediate zone (average 2-6.4 microns/hr) slowing only transiently on entry into the developing cortex. Within the cortex, Qr and Qs merge to form a single distribution most concentrated over layer V.

NASA Discipline Neuroscience↗

Geochemistry of Pallasite Olivines and the Origin of Main-Group Pallasites

Main-group pallasites (PMG) are mixtures of iron-nickel metal and magnesian olivine thought to have been formed at the core-mantle boundary of an asteroid [1]. Some have anomalous metal compositions (PMG-am) and a few have atypically ferroan olivines (PMG-as) [2]. PMG metal is consistent with an origin as a late fractionate of the IIIAB iron core [2]. Most PMG olivines have very similar Fe/Mg ratios, likely due to subsolidus redox reaction with the metal [3]. In contrast, minor and trace elements show substantial variation, which may be explained by either: (i) PMG were formed at a range of depths in the parent asteroid; the element variations reflect variations in igneous evolution with depth, (ii) the pallasite parent asteroid was chemically heterogeneous; the heterogeneity partially survived igneous processing, or (iii) PMG represent the core-mantle boundaries of several distinct parent asteroids [4, 5]. We have continued doing major, minor and trace elements by EMPA and INAA on a wider suite of PMG olivines, and have begun doing precise oxygen isotope analyses to test these hypotheses. Manganese is homologous with Fe(2+), and can be used to distinguish between magmatic and redox processes as causes for Fe/Mg variations. PMG olivines have a range in molar 1000*Mn/Mg of 2.3-4.6 indicating substantial igneous fractionation in olivines with very similar Fe/Mg (0.138-0.148). The Mg-Mn-Fe distributions can be explained by a fractional crystallization-reduction model; higher Mn/Mg ratios reflect more evolved olivines while Fe/Mg is buffered by redox reactions with the metal. There is a positive association between Mn/Mg and Sc content that is consistent with igneous fractionation. However, most PMG olivines fall within a narrow Mn/Mg range (3.0-3.6), but these show a substantial range in Sc (1.00-2.29 micro-g/g). Assuming fractional crystallization, this Sc range could have resulted from approx.65% crystallization of an ultramafic magma. This is inconsistent with formation at the core-mantle boundary of a single asteroid [4]. One alternative is that the PMG are fragments of several asteroids, and these could have had different initial Sc contents, Mn/Mg and differences in igneous history. Our preliminary O isotope data and those of [6, 7] do not support this, although the coverage of PMG olivines is incomplete. The PMG-as Springwater is not easily fit in any scenario. Its olivine has among the highest Mn/Mg suggesting it is one of the most evolved, but the lowest Sc content suggesting it is the least evolved. The O isotopic composition of Springwater olivine is the same as that of other PMG. Thus there is no indication that it represents a distinct parent asteroid. Our preliminary O isotopic data favor a single PMG parent asteroid. In this case, the olivines are more likely melt-residues, and that the parent asteroid was initially heterogeneous in chemical, but not isotopic, composition.

Mittlefehldt, D. W.↗

Method for separating single-wall carbon nanotubes and compositions thereof

The invention relates to a process for sorting and separating a mixture of (n, m) type single-wall carbon nanotubes according to (n, m) type. A mixture of (n, m) type single-wall carbon nanotubes is suspended such that the single-wall carbon nanotubes are individually dispersed. The nanotube suspension can be done in a surfactant-water solution and the surfactant surrounding the nanotubes keeps the nanotube isolated and from aggregating with other nanotubes. The nanotube suspension is acidified to protonate a fraction of the nanotubes. An electric field is applied and the protonated nanotubes migrate in the electric fields at different rates dependent on their (n, m) type. Fractions of nanotubes are collected at different fractionation times. The process of protonation, applying an electric field, and fractionation is repeated at increasingly higher pH to separated the (n, m) nanotube mixture into individual (n, m) nanotube fractions. The separation enables new electronic devices requiring selected (n, m) nanotube types.

Smalley, Richard E.↗

A Spectroscopic Search for Leaking Lyman Continuum at Zeta Approximately 0.7

We present the results of rest-frame, UV slitless spectroscopic observations of a sample of 32 z approx. 0.7 Lyman Break Galaxy (LBG) analogs in the COSMOS field. The spectroscopic search was performed with the Solar Blind Channel (SBC) on HST. While we find no direct detections of the Lyman Continuum we achieve individual limits (3sigma) of the observed non-ionizing UV to Lyman continuum flux density ratios, f(sub nu)(1500A)/f(sub nu)(830A) of 20 to 204 (median of 73.5) and 378.7 for the stack. Assuming an intrinsic Lyman Break of 3.4 and an optical depth of Lyman continuum photons along the line of sight to the galaxy of 85% we report an upper limit for the relative escape fraction in individual galaxies of 0.02 - 0.19 and a stacked 3sigma upper limit of 0.01. We find no indication of a relative escape fraction near unity as seen in some LBGs at z approx. 3. Our UV spectra achieve the deepest limits to date at any redshift on the escape fraction in individual sources. The contrast between these z approx. 0.7 low escape fraction LBG analogs with z approx. 3 LBGs suggests that either the processes conducive to high f(sub esc) are not being selected for in the z less than or approx.1 samples or the average escape fraction is decreasing from z approx. 3 to z approx. 1. We discuss possible mechanisms which could affect the escape of Lyman continuum photons

Bridge, Carrie R.↗

Highly Siderophile Element Abundances in Martian Meteorites

Critical evaluation of new and literature data for highly siderophile elements (HSE) in Martian (SNC) meteorites allows several first order conclusions to be drawn. (i) Re concentrations in SNC meteorites are nearly constant (within a factor of two) and do not correlate with rock type. Exceptions to this rule are Chassigny and Dar al Gani (DaG) 476, both of which are inferred to have experienced terrestrial Re contamination. (ii) Fractionations between Rh and Pd are small. Excluding Shergotty, the Rh/Pd ratio of the SNC suite is 0.22\pm0.05. (iii) Os and Ir contents vary by about four orders of magnitude; and positive correlations with MgO, Cr, and Ni suggest that these variations are not controlled by sulfide fractionation. A possible exception is the orthopyroxenite ALH84001, whose HSE's (including Ni, which is compatible in opx) are very low. (iv) Zagami, Shergotty, and Nakhla have nearly identical HSE signatures. Shergotty and Zagami have experienced assimilation-fractional crystallization (AFC) and have "crustal" Sr and Nd isotopic signatures. Conversely, the Nakhla parent was a small degree partial melt of a depleted mantle that interacted little with the Martian crust. These observations suggest that "evolved" HSE signatures can be produced by either fractional crystallization or small degrees of partial melting. (v) Chassigny and other mafic SNC's have HSE signatures that are very distinct from those of Nakhla-Zagami-Shergotty. The HSE elemental ratios of mafic SNC's approach chondritic, implying that the Martian mantle has nearly chondritic relative abundances of the HSE's. (vi) This chondritic HSE signature is observed in SNC's of various ages, suggesting that this is an ancient feature that has not evolved over time. (vii) No correlation is observed between HSE's and signatures of crustal contamination (e.g., Sr isotopes), indicating that the HSE signatures of the SNC suite are not derived from the crust. (vii) The Ru/Pd for the SNC suite ratio is about 0.5 chondritic. We attribute this depletion of Ru to the presence of spinel in the SNC source regions. (viii) Assignment of this depletion of Ru to spinel seems to also imply that spinel is not the cause of Os and Ir fractionations, requiring some other mafic phase to account for the observed variations. -----.

Jones, J. H.↗

The Composition of Titan's Lower Atmosphere and Simple Surface Volatiles as Measured by the Cassini-Huygens Probe Gas Chromatograph Mass Spectrometer Experiment

The Cassini-Huygens Probe Gas Chromatograph Mass Spectrometer (GCMS) determined the composition of the Titan atmosphere from ~140km altitude to the surface. After landing, it returned composition data of gases evaporated from the surface. Height profiles of molecular nitrogen (N2), methane (CH4) and molecular hydrogen (H2) were determined. Traces were detected on the surface of evaporating methane, ethane (C2H6), acetylene (C2H2), cyanogen (C2N2) and carbon dioxide (CO2). The methane data showed evidence that methane precipitation occurred recently. The methane mole fraction was (1.48+/-0.09) x 10(exp -2) in the lower stratosphere (139.8 km to 75.5 km) and (5.65+/-0.18) x 10(exp -2) near the surface (6.7 km to the surface). The molecular hydrogen mole fraction was (1.01+/-0.16) x 10(exp -3) in the atmosphere and (9.90+/-0.17) x 10(exp -4) on the surface. Isotope ratios were 167.7+/-0.6 for N-14/N-15 in molecular nitrogen, 91.1+/-1.4 for C-12/C-13 in methane and (1.35+/-0.30) x 10(exp -4) for D/H in molecular hydrogen. The mole fractions of Ar-36 and radiogenic Ar-40 are (2.1+/-0.8) x 10(exp -7) and (3.39 +/-0.12) x 10(exp -5) respectively. Ne-22 has been tentatively identified at a mole fraction of (2.8+/-2.1) x 10(exp -7) Krypton and xenon were below the detection threshold of 1 x 10(exp -8) mole fraction. Science data were not retrieved from the gas chromatograph subsystem as the abundance of the organic trace gases in the atmosphere and on the ground did not reach the detection threshold. Results previously published from the GCMS experiment are superseded by this publication.

Niemann, H. B.↗

A Model of Thermal Conductivity for Planetary Soils: Theory for Cemented Soils - 2

A numerical model of heat conduction through particulate media made of spherical grains cemented by various bonding agents is presented. The pore-filling gas conductivity, volume fraction, and thermal conductivity of the cementing phase are tunable parameters. Cement fractions <0.001-0.01% in volume have small effects on the soil bulk thermal conductivity. A significant conductivity increase (factor 3-8) is observed for bond fractions of 0.01 to 1% in volume. In the 1 to 15% bond fraction domain, the conductivity increases continuously but less intensely (25-100% conductivity increase compared to a 1% bond system). Beyond 15% of cements, the conductivity increases vigorously and the bulk conductivity rapidly approaches that of bedrock. The composition of the cements (i.e. conductivity) has little influence on the bulk thermal inertia of the soil, especially if the volume of bond <10%. These results indicate that temperature measurements are sufficient to detect cemented soils and quantify the amount of cementing phase, but the mineralogical nature of the bonds and the typical grain size are unlikely to be determined from orbit. On Mars, a widespread surface unit characterized by a medium albedo (0.19-0.26) and medium/high thermal inertia (200-600 J s(0.5)/sq m/K) has long been hypothesized to be associated with a duricrust. The fraction of cement required to fit the thermal data is less than approx.1-5% by volume. This small amount of material is consistent with orbital observations, confirming that soil cementation is an important factor controlling the thermal inertia of the Martian surface

Piqueux, S.↗

Trace Element Compositions of Pallasite Olivine Grains and Pallasite Origin

Pallasites are mixtures of metal with magnesian olivine. Most have similar metal compositions and olivine oxygen isotopic compositions; these are the main-group pallasites (PMG). The Eagle Station grouplet of pallasites (PES) have distinctive metal and olivine compositions and oxygen isotopic compositions. Pallasites are thought to have formed at the core-mantle boundary of their parent asteroids by mixing molten metal with solid olivine of either cumulatic or restitic origin. We have continued our investigation of pallasite olivines by doing in situ trace element analyses in order to further constrain their origin. We determined Al, P, Ca, Ga and first row transition element contents of olivine grains from suite of PMG and PES by LA-ICP-MS at JSC. Included in the PMG suite are some that have anomalous metal compositions (PMG-am) and atypically ferroan olivines (PMG-as). Our EMPA work has shown that there are unanticipated variations in olivine Fe/Mn, even within those PMG that have uni-form Fe/Mg. Manganese is homologous with Fe2+, and thus can be used the same way to investigate magmatic fractionation processes. It has an advantage for pallasite studies in that it is unaffected by redox exchange with the metal. PMG can be divided into three clusters on the basis of Mn/Mg; low, medium and high that can be thought of as less, typically and more fractionated in an igneous sense. The majority of PMG have medium Mn/Mg ratios. PMG-am occur in all three clusters; there does not seem to be any relationship between putative olivine igneous fractionation and metal composition. The PMG-as and one PMG-am make up the high Mn/Mg cluster; no PMG are in this cluster. The high Mn/Mg cluster ought to be the most fractionated (equivalent to the most Fe-rich in igneous suites), yet they have among the lowest contents of incompatible lithophile elements Al and Ti and the two PMG-as in this cluster also have low Ca and Sc contents. This is inconsistent with simple igneous fractionation on a single, initially homogeneous parent asteroid. For Al and Ti, the low and high Mn/Mg clusters have generally uniform contents, while the medium cluster has wide ranges. This is also true of analyses of duplicate grains from the medium cluster pallasites which can have very different Al and Ti contents. Those from the low and high clusters do not. These observations suggest that pallasite olivines are not cumulates, but rather are restites from high degrees of melting. The moderately siderophile elements P and Ga show wide ranges in the high Mn/Mg cluster, but very uniform compositions in the medium cluster, opposite the case for Al and Ti. There is no correlation of P or Ga and Fe/Mn as might be expected if redox processes controlled the contents of moderately siderophile elements in the olivines. The lack of correlation of P could reflect equilibration with phosphates, although there is no correlation of Ca with P as might be expected

Mittlefehldt, David W.↗

Analyses of Cometary Silicate Crystals: DDA Spectral Modeling of Forsterite

Comets are the Solar System's deep freezers of gases, ices, and particulates that were present in the outer protoplanetary disk. Where comet nuclei accreted was so cold that CO ice (approximately 50K) and other supervolatile ices like ethane (C2H2) were preserved. However, comets also accreted high temperature minerals: silicate crystals that either condensed (greater than or equal to 1400 K) or that were annealed from amorphous (glassy) silicates (greater than 850-1000 K). By their rarity in the interstellar medium, cometary crystalline silicates are thought to be grains that formed in the inner disk and were then radially transported out to the cold and ice-rich regimes near Neptune. The questions that comets can potentially address are: How fast, how far, and over what duration were crystals that formed in the inner disk transported out to the comet-forming region(s)? In comets, the mass fractions of silicates that are crystalline, f_cryst, translate to benchmarks for protoplanetary disk radial transport models. The infamous comet Hale-Bopp has crystalline fractions of over 55%. The values for cometary crystalline mass fractions, however, are derived assuming that the mineralogy assessed for the submicron to micron-sized portion of the size distribution represents the compositional makeup of all larger grains in the coma. Models for fitting cometary SEDs make this assumption because models can only fit the observed features with submicron to micron-sized discrete crystals. On the other hand, larger (0.1-100 micrometer radii) porous grains composed of amorphous silicates and amorphous carbon can be easily computed with mixed medium theory wherein vacuum mixed into a spherical particle mimics a porous aggregate. If crystalline silicates are mixed in, the models completely fail to match the observations. Moreover, models for a size distribution of discrete crystalline forsterite grains commonly employs the CDE computational method for ellipsoidal platelets (c:a:b=8.14x8.14xl in shape with geometrical factors of x:y:z=1:1:10, Fabian et al. 2001; Harker et al. 2007). Alternatively, models for forsterite employ statistical methods like the Distribution of Hollow Spheres (Min et al. 2008; Oliveira et al. 2011) or Gaussian Random Spheres (GRS) or RGF (Gielen et al. 200S). Pancakes, hollow spheres, or GRS shapes similar to wheat sheaf crystal habit (e.g., Volten et al. 2001; Veihelmann et al. 2006), however, do not have the sharp edges, flat faces, and vertices seen in images of cometary crystals in interplanetary dust particles (IDPs) or in Stardust samples. Cometary forsterite crystals often have equant or tabular crystal habit (J. Bradley). To simulate cometary crystals, we have computed absorption efficiencies of forsterite using the Discrete Dipole Approximation (DDA) DDSCAT code on NAS supercomputers. We compute thermal models that employ a size distribution of discrete irregularly shaped forsterite crystals (nonspherical shapes with faces and vertices) to explore how crystal shape affects the shape and wavelength positions of the forsterite spectral features and to explore whether cometary crystal shapes support either condensation or annealing scenarios (Lindsay et al. 2012a, b). We find forsterite crystal shapes that best-fit comet Hale-Bopp are tetrahedron, bricks or brick platelets, essentially equant or tabular (Lindsay et al. 2012a,b), commensurate with high temperature condensation experiments (Kobatake et al. 2008). We also have computed porous aggregates with crystal monomers and find that the crystal resonances are amplified. i.e., the crystalline fraction is lower in the aggregate than is derived by fitting a linear mix of spectral features from discrete subcomponents, and the crystal resonances 'appear' to be from larger crystals (Wooden et al. 2012). These results may indicate that the crystalline mass fraction in comets with comae dominated by aggregates may be lower than deduced by popular methods that only emoy ensembles of discrete crystals.

Wooden, Diane↗

Potassium Stable Isotopic Compositions Measured by High-Resolution MC-ICP-MS

Potassium isotopic (K-41/K-39) compositions are notoriously difficult to measure. TIMS measurements are hindered by variable fractionation patterns throughout individual runs and too few isotopes to apply an internal spike method for instrumental mass fractionation corrections. Internal fractionation corrections via the K-40/K-39 ratio can provide precise values but assume identical K-40/K-39 ratios (e.g. 0.05% (1sigma) in [1]); this is appropriate in some cases (e.g. identifying excess K-41) but not others (e.g., determining mass fractionation effects and metrologically traceable isotopic abundances). SIMS analyses have yielded measurements with 0.25% precisions (1sigma) [2]. ICP-MS analyses are significantly affected by interferences from molecular species such as Ar-38H(+) and Ar-40H(+) and instrument mass bias. Single collector ICP-MS instruments in "cold plasma" mode have yielded uncertainties as low as 2% (1sigma, e.g. [3]). Although these precisions may be acceptable for some concentration determinations, they do not resolve isotopic variation in terrestrial materials. Here we present data from a series of measurements made on the Thermo Scientific NEPTUNE Plus multi-collector ICP-MS that demonstrate the ability to make K-41/K-39 ratio measurements with 0.07% precisions (1sigma). These data, collected on NIST K standards, indicate the potential for MC-ICP-MS measurements to look for K isotopic variations at the sub-permil level. The NEPTUNE Plus can sufficiently resolve 39K and 41K from the interfering 38ArH+ and 40ArH+ peaks in wet cold plasma and high-resolution mode. Measurements were made on small but flat, interference-free, plateaus (ca. 50 ppm by mass width for K-41). Although ICP-MS does not yield accurate K-41/K-39 values due to significant instrumental mass fractionation (ca. 6%), this bias can be sufficiently stable over the time required for several measurements so that relative K-41/K-39 values can be precisely determined via sample-standard bracketing. As cold plasma conditions can amplify matrix effects, experiments were conducted to test the matrix tolerance of measurements; the use of clean, matrix-matched samples and standards is critical. Limitations of the cold-plasma high-resolution MC-ICP-MS methodology with respect to matrix tolerance are discussed and compared with the limitations of TIMS methodologies.

Morgan, Leah E.↗

Electrostatic Beneficiation of Lunar Simulant

Electrostatic beneficiation of lunar regolith is a method allowing refinement of specific minerals in the material for processing on the moon. The use of tribocharging the regolith prior to separation was investigated on the lunar simulant MLS-I by passing the dust through static mixers constructed from different materials; aluminum, copper, stainless steel, and polytetrafluoroethylene (PTFE). The amount of charge acquired by the simulant was dependent upon the difference in the work function of the dust and the charging material. XPS and SEM were used to characterize the simulant after it was sieved into five size fractions (> 100 pm, 75-100 pm, 50- 75 pm, 50-25 pm, and < 25 pm), where very little difference in surface composition was observed between the sizes. Samples of the smallest (< 25 pm) and largest (> 100 pm) size fractions were beneficiated through a charge separator using the aluminum (charged the simulant negatively) and PTFE (charged positively) mixers. The mass fractions of the separated simulant revealed that for the larger particle size, significant unipolar charging was observed for both mixers, whereas for the smaller particle sizes, more bipolar charging was observed, probably due to the finer simulant adhering to the inside of the mixers shielding the dust from the charging material. Subsequent XPS analysis of the beneficiated fractions showed the larger particle size fraction having some species differentiation, but very little difference for the smaller.size. Although MLS-1 was made to have similar chemistry to actual lunar dust, its mineralogy is quite different. On-going experiments are using NASA JSC-1 lunar simulant. A vacuum chamber has been constructed, and future experiments are planned in a simulated lunar environment.

Trigwell, Steve↗

The Interaction Between Boundary Layer and Convection Schemes in a WRF Simulation of Post‐Cold‐Frontal Clouds over the ARM East North Atlantic Site

The correct representation of lowlevel midlatitude clouds found in the wake of cold fronts strongly relies on the representation of planetary boundary layer (PBL) and convection processes, which are typically parameterized separately in numerical models. Using the Weather Research and Forecasting Model (WRF), this study investigates how distinct pairs of PBL and convection parameterization schemes represent cloud fraction in the postcoldfrontal region. The simulations focus on the region of the DOEARM Eastern North Atlantic observation site in the Azores Islands in the wake of a cold front that passed on December 25, 2015. Different PBL and convection schemes are combined to create 12 distinct configurations. The main differences between the selected physical parameterizations are the strength of vertical mixing and the entrainment. The simulations produce a wide range of cloud fractions, where some configurations significantly underestimate while others clearly overestimate satellite and surfacebased estimates of cloud fraction. A skill score is used to quantitatively assess the performance of each configuration with respect to groundbased radar data. The key processes that are found to significantly impact the cloud fraction distribution are the strength of the PBL decoupling, the vertical wind shear, entrainment and detrainment rates in shallow convection and the occurrence of drizzle. This indicates that to successfully simulate postcoldfrontal clouds, modeled physics must balance strong internal vertical mixing and weak exchange with the free troposphere. For this case study, cloud fraction was more sensitive to the choice of convection scheme than PBL scheme.

moist convection interaction between parameterizat↗

Small Launch Vehicle Sizing Analysis with Solid Rocket Examples

Small launch vehicles are governed by the same physics as large launch vehicles of course, but due to their small size, some aspects and sensitivities become more important and others less. This paper shows semi-empirical correlations to quantify dry mass fraction for both stage and whole vehicle optimization: mass fraction due to density, mass fraction due to thrust-to-weight, and mass fraction due to size reduction. For single-stage optimizations, a stage performance requirement can be met by a locus of mass fraction vs. specific impulse. Based on the above correlations, this alone can recommend a solid or liquid rocket for a stage. Rocket designs of similar technology levels are compared, focusing on where stages become less mass-efficient as they get smaller. The Mars Ascent Vehicle is shown to exemplify a trade between a two-stage solids vehicle and a one- or two-stage liquids vehicle.

Kibbey, Tim↗

Small Launch Vehicle Sizing Analysis With Solid Rocket Examples

Small launch vehicles are governed by the same physics as large launch vehicles of course, but due to their small size, some aspects and sensitivities become more important and others less. This paper shows semi-empirical correlations to quantify dry mass fraction for both stage and whole vehicle optimization: mass fraction due to density, mass fraction due to thrust-to-weight, and mass fraction due to size reduction. For single-stage optimizations, a stage performance requirement can be met by a locus of mass fraction vs. specific impulse. Based on the above correlations, this alone can recommend a solid or liquid rocket for a stage. Rocket designs of similar technology levels are compared, focusing on where stages become less mass-efficient as they get smaller. The Mars Ascent Vehicle is shown to exemplify a trade between a two-stage solids vehicle and a one- or two-stage liquids vehicle.

Kibbey, Tim↗

Investigating Sources of Variability and Error in Simulations of Carbon Dioxide in an Urban Region

Greenhouse gas (GHG) emissions estimation methods that use atmospheric trace gas observations, including inverse modeling techniques, perform better when carbon dioxide (CO2) fluxes are more accurately transported and dispersed in the atmosphere by a numerical model. In urban areas, transport and dispersion is particularly difficult to simulate using current mesoscale meteorological models due, in part, to added complexity from surface heterogeneity and fine spatial/temporal scales. It is generally assumed that the errors in GHG estimation methods in urban areas are dominated by errors in transport and dispersion. Other significant errors include, but are not limited to, those from assumed emissions magnitude and spatial distribution. To assess the predictability of simulated trace gas mole fractions in urban observing systems using a numerical weather prediction model, we employ an Eulerian model that combines traditional meteorological variables with multiple passive tracers of atmospheric CO2 from anthropogenic inventories and a biospheric model. The predictability of the Eulerian model is assessed by comparing simulated atmospheric CO2 mole fractions to observations from four in situ tower sites (three urban and one rural) in the Washington DC/Baltimore, MD area for February 2016. Four different gridded fossil fuel emissions inventories along with a biospheric flux model are used to create an ensemble of simulated atmospheric CO2 observations within the model. These ensembles help to evaluate whether the modeled observations are impacted more by the underlying emissions or transport. The spread of modeled observations using the four emission fields indicates the model's ability to distinguish between the different inventories under various meteorological conditions. Overall, the Eulerian model performs well; simulated and observed average CO2 mole fractions agree within 1% when averaged at the three urban sites across the month. However, there can be differences greater than 10% at any given hour, which are attributed to complex meteorological conditions rather than differences in the inventories themselves. On average, the mean absolute error of the simulated compared to actual observations is generally twice as large as the standard deviation of the modeled mole fractions across the four emission inventories. This result supports the assumption, in urban domains, that the predicted mole fraction error relative to observations is dominated by errors in model meteorology rather than errors in the underlying fluxes in winter months. As such, minimizing errors associated with atmospheric transport and dispersion may help improve the performance of GHG estimation models more so than improving flux priors in the winter months. We also find that the errors associated with atmospheric transport in urban domains are not restricted to certain times of day. This suggests that atmospheric inversions should use CO2 observations that have been filtered using meteorological observations rather than assuming that meteorological modeling is most accurate at certain times of day (such as using only mid-afternoon observations).

CO2↗

The Impact of Neglecting Ice Phase on Cloud Optical Depth Retrievals from AERONET Cloud Mode Observations

Clouds present many challenges to climate modelling. To develop and verify the parameterisations needed to allow climate models to represent cloud structure and processes, there is a need for high-quality observations of cloud optical depth from locations around the world. Retrievals of cloud optical depth are obtainable from radiances measured by Aerosol Robotic Network (AERONET) radiometers in “cloud mode” using a two-wavelength retrieval method. However, the method is unable to detect cloud phase, and hence assumes that all of the cloud in a profile is liquid. This assumption has the potential to introduce errors into long term statistics of retrieved optical depth for clouds that also contain ice. Using a set of idealized cloud profiles we find that, for optical depths above 20, the fractional error in retrieved optical depth is a linear function of the fraction of the optical depth that is due to the presence of ice cloud (“ice fraction”). Clouds that are entirely ice have positive errors with magnitudes of the order of 55% to 70 %. We derive a simple linear equation that can be used as a correction at AERONET sites where ice fraction can be independently estimated. Using this linear equation, we estimate the magnitude of the error for a set of cloud profiles from five sites of the Atmospheric Radiation Measurement programme. The dataset contains separate retrievals of ice and liquid retrievals; hence ice fraction can be estimated. The magnitude of the error at each location was related to the relative frequencies of occurrence in thick frontal cloud at the mid-latitude sites and of deep convection at the tropical sites – that is, of deep cloud containing both ice and liquid particles. The long-term mean optical depth error at the five locations spans the range 2– 4, which we show to be small enough to allow calculation of top-of-atmosphere flux to within 10% and surface flux to about 15 %.

Shonk, Jonathan K. P.↗

A Comparison of NO Laser-Induced Fluorescence Models at Conditions Relevant to Supersonic and Hypersonic Flows

Planar laser-induced fluorescence (PLIF) of the nitric oxide (NO) molecule has been widely used in wind tunnel facilities for flow visualization, velocity, and temperature measurements. The experimental PLIF measurements are often compared with synthetic PLIF images using computationally derived temperatures, pressures, velocities, and species mole fractions. This approach is commonly referred to as computational flow imaging (CFI). In the present work, we compare signal intensity from PLIF models with experimental PLIF measurements obtained within a low pressure gas cell system at pressures and NO mole fractions relevant to supersonic and hypersonic flowfields. Experimental measurements were compared to several different laser induced-fluorescence models reported in the literature including LIFBASE, LINUS, and a NASA two-level model. The experimental measurements agreed well with all of the models at lower pressures and lower NO mole fractions; the fluorescence there is linear with both of these parameters. However, at higher pressures and mole fractions, the signal becomes nonlinear with respect to these parameters as self-quenching limits the signal and absorption further limits the signal. In fact, for the experimental path length of the experiment, the combination of high pressure and high NO mole fraction causes the experimental results to deviate significantly from the predicted results that neglect absorption of the incident laser sheet. The LINUS model, which allows absorption to be calculated, provided results that agreed better with the experimental measurements. Since supersonic and hypersonic flowfields may contain a region of the flow with high pressures and measurements in large-scale facilities often include a long path length, neglecting absorption may have a significantly negative effect on the CFI comparison to experimental PLIF images. As a result, PLIF models that account for absorption should be included in computational flow imaging approaches for laser induced fluorescence.

laser-induced fluorescence↗