Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “flow analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 865 records · Page 48

Reactivity of CO 2 with Utica, Marcellus, Barnett, and Eagle Ford Shales and Impact on Permeability

We report that in order to reduce greenhouse gas emissions while recovering hydrocarbons from unconventional shale formations, processes that make use of carbon dioxide to enhance oil recovery while storing carbon dioxide (CO 2 ) should be considered. Here, we examine samples from three shale basins across the United States (Utica and Marcellus Shales in the Appalachian Basin, Barnett Shale in the Bend Arch-Ft. Worth Basin, and Eagle Ford in the Western Gulf Basin) to address the following questions: (1) do changes from reaction with CO 2 and fluids at the micrometer and nanometer scale alter flow pathways and, in turn, impact hydrocarbon production, CO 2 storage, and seal integrity and (2) can CO 2 or fluid reactivity be predicted based on physical or chemical properties of shale formations? Experiments were conducted at 40 °C and 10.3 MPa to characterize the interaction between CO 2 and shale using X-ray diffraction (XRD), carbon and sulfur analysis, in situ Fourier transform infrared spectroscopy (FT-IR), feature relocation scanning electron microscopy coupled with energy-dispersive spectroscopy (SEM-EDS), mercury (Hg) intrusion porosimetry, and Brunauer-Emmett-Teller (BET) surface area and pore size analysis coupled with density functional theory (DFT) methods. Changes in mechanical, physical, and flow properties of shale cores due to CO 2 exposure were addressed using a New England Research Autolab 1500 and Xenon X-ray computed tomography (CT) scanning. Results showed that CO 2 did not promote significant reactivity with the shale if water was not present; only shales with swelling clays or residual interstitial pore water reacted with dry CO 2 to promote reactivity in shale. When water was added as a reactant, CO 2 formed carbonic acid and reacted with the shale to dissolve carbonate pockets, etched and pitted the shale matrix surfaces, and increased the microporosity and decreased nanoporosity. Porosity and permeability increased appreciably in core shale samples after exposure to CO 2 saturated fluid due to dissolution of carbonate. Shale mechanical properties were not altered. Trends were not observed that could tie CO 2 or fluid reactivity to physical or chemical properties of the shale formations at the basin scale from the samples we examined. However, if the shale contained significant amounts of carbonate and water was available to react with the CO 2 , pore sizes were altered in the matrix and permeability and porosity increased.

04 OIL SHALES AND TAR SANDS↗

Optimizing the Heisenberg Vortex Tube for Hydrogen Cooling (Final Technical Report)

Hydrogen utilization at Plug Power sites ranges between 70-93% with the remainder vented and lost to the atmosphere. The goal of this project was to improve hydrogen utilization at Plug Power fulfillment centers via the patented Heisenberg vortex tube (HVT). The HVT combines conventional counterflow vortex tubes with para-orthohydrogen conversion catalyst to allow the cooling of hydrogen flows with no moving parts or external energy inputs. In year 1 of this project the HVT was evaluated to improve hydrogen utilization via the following concepts: 1) increasing liquid hydrogen pump volumetric efficiency by 20% through vapor separation and subcooling of the liquid, 2) reducing liquid hydrogen storage tank boil-off losses by 20% through thermal vapor shielding (TVS), and 3) increase isentropic efficiency of supercritical hydrogen expansion at 40-50 K, from 31% to over 40%. The TVS concept was selected as the most favorable application for further development. While the conceptual analysis was underway, the cryocatalysis hydrogen experiment facility (CHEF) was retrofitted with a new cryocooler, higher pressure condenser tanks, and in-situ fiber-optic Raman probes for ortho-parahydrogen composition analysis at the inlets and outlets of the HVT. To our knowledge this is the first in-situ implementation of cryogenic Raman probes for ortho-parahydrogen analysis. Subsequent testing of catalyzed and non-catalyzed HVT identified a low flow rate, high-conversion efficacy regime well suited for TVS development. Computational fluid dynamics (CFD), Reduced order modeling (ROM), and quantum Monte Carlo atomistic simulations were applied to optimize the design of the HVT implemented for TVS. The simulations and analysis identified a ruthenium-based catalyst as the most optimal for high conversion with little pressure losses and was matched to experimental measurements. These results indicated the design could achieve the 20% boil-off reduction target. An HVT field-trial was designed and constructed by Plug Power and implemented at a customer site. However, budget limitations reduced the amount of catalyst that could be applied to the HVT. With the reduced amount of catalyst, CFD analysis estimated about 3% reduction in boil-off. A similar amount of boil-off reduction was observed during preliminary measurements during tank commissioning. However, the results have a large margin for error and were operated at relatively low tank temperatures when the HVT has the lowest potential for improvement. This project demonstrated the use of para-orthohydrogen catalysis for reducing liquid hydrogen tank boil-off losses. The field trial system is anticipated to provide long-term experimental measurements on tank operational performance that will allow Plug Power to instrument additional tanks in the future. Recommendations for future work include the development of higher activity, lower cost para-orthohydrogen conversion catalyst for use in the HVT. Tank process optimizations could maximize the efficacy of the HVT and further improve hydrogen utilization.

08 HYDROGEN↗

OPTIMIZATION OF A NUCLEAR VESSEL OUTLET FOR INCIDENT MONITORING

Classical nuclear core fluidic design techniques require improvement to better align with modern technological innovations. The US Department of Energy’s Office of Nuclear Energy (DOE-NE) Transformational Challenge Reactor (TCR) program is deploying additive manufacturing and advanced modeling and simulation to reimagine these designs. With the aid of modern computing power, computerized design optimization can be implemented to remove unwanted pressure drop while simultaneously optimizing flow structures, resulting in new opportunities to enable advanced instrumentation and monitoring capabilities.Previous development of geometric specifications for the TCR pressure vessel’s outlet plenum used design optimization to (1) limit pressure losses below 3.5 kPa (~0.5 psi) and (2) create a fluidic plane in which the temperature variation would not exceed ±5°C. This significant limit of the allowable pressure drop stems from the overarching goal of the TCR program to apply cutting edge techniques and unconventional thinking to demonstrate potential opportunities in additive manufacturing (AM).This paper expands the previous work by optimizing thermowell locations for robust measurements by explicitly modeling them and the resulting flow impacts. Additionally, a single core coolant channel was chosen to represent an event that causes an increased bulk flow temperature increase of 100°C.High fidelity unsteady Reynolds-averaged Navier-Stokes (URANS) simulations of the conjugate heat transfer problem were run in Siemen’s Star-CCM+ for this study. Next, the bulk flow temperature of a single coolant channel was increased by 100°C and was allowed to converge again. Finally, statistical analysis using a sequential probability ratio test (SPRT) was used to determine the elapsed time the thermocouples took to discover the increased bulk flow temperature.

See, Nate↗

Validation of OpenPronghorn for Periodic Hill Flow Separation

OpenPronghorn is an open-source, MOOSE-based thermal-hydraulics simulation tool used for advanced reactor analysis. As an open-source code, it offers a transparent framework for validating governing equations, assumptions, and numerical methods against established benchmarks. This study evaluates OpenPronghorn's RANS turbulence model against the ERCOFTAC Case 81 periodic hill benchmark, a standard test case for separated turbulent flow featuring curved-wall separation, recirculation, shear-layer development, and reattachment. Streamwise velocity profiles predicted by OpenPronghorn were compared to reference LES data at multiple x/h locations. Results show that OpenPronghorn captures the overall trend of the velocity profiles, but the largest discrepancies occur in the separated-flow region, where turbulence is highly anisotropic and strongly affected by adverse pressure gradients and wall curvature—conditions that are inherently difficult for standard RANS models to resolve. Future work will test alternative k-e model variants and correction terms to improve prediction accuracy in this region.

42 - ENGINEERING↗

Modeling Isothermal Reduction of Iron Ore Pellet Using Finite Element Analysis Method: Experiments & Validation

Iron ore pellet reduction experiments were performed with pure hydrogen (H2) and mixtures with carbon monoxide (CO) at different ratios. For direct reduction processes that switch dynamically between reformed natural gas and hydrogen as the reductant, it is important to understand the effects of the transition on the oxide reduction kinetics to optimize the residence time of iron ore pellets in a shaft reactor. Hence, the reduction rates were studied by varying experimental parameters such as the temperature (800, 850 & 900 °C), reactant gas flow rate (100, 150 & 200 cm3/min), pellet size and composition of the reactant gas mixture. The rate of reduction was observed to increase with an increase in temperature and reactant gas flow rate, but it decreased with an increase in pellet size. SEM greyscale analysis was performed to analyze the porosity and phase composition of partially reduced pellets. The porosity of the pellets was observed to increase from 0.3 for unreacted pellet to 0.42 for a completely reduced pellet. Energy-dispersive X-ray spectroscopy (EDAX) analysis was performed to identify the phases observed in the SEM images. The fraction of iron phase was observed to increase from the shell region of the pellet to the core region with an increase in the degree of reduction. A 2D-axisymmetric numerical model was developed on COMSOL Multiphysics, and it was validated using the conversion (X) vs. time curves obtained from each experiment. The model was able to accurately predict the total time needed for the complete conversion of a single iron ore pellet for multiple experiments. Effects of changes in the porosity and tortuosity of the pellet on the model were also studied and the rate of reduction was observed to be sensitive to changes in both porosity and tortuosity. The SEM analysis and the model results show that tortuosity is higher for pellets reduced with H2 than for pellets reduced with H2-CO gas mixtures.

08 HYDROGEN↗

An experimental investigation on the CO 2 storage capacity of the composite confining system

Assuring secure containment of stored CO 2 is of paramount importance—for climate change mitigation, for permitting, and for reassuring the public. Regional seals, such as those sealing petroleum accumulations, have proven to be effective for securing CO 2 . However, the goal of permanent sequestration can also be satisfied with “composite confining systems” consisting of multiple, possibly discontinuous flow barriers that, in aggregate, create a system with very high permeability anisotropy and effectively retard the vertical migration of CO 2 . This study focuses on investigating the barrier characteristics necessary for effective containment of CO 2 , using both physical flow experiments and modified invasion percolation simulations. The simulations are calibrated to the physical experiments and are used to further extend the analysis. Results show that for a composite confining system, a) even barriers with low capillary entry pressure contrast to the underlying flow unit can divert rising CO 2 ; b) curved or anticlinal barrier topography can enhance CO 2 trapping; c) fining-upward gradations make little difference to barrier effectiveness or CO 2 retention; d) longer barriers retain more CO 2 regardless of barrier topography. Finally, field-scale simulations have demonstrated the importance of barrier length for increasing CO 2 storage capacity. Furthermore, the results presented can be used to inform the development of new screening criteria for characterization and effectiveness of composite confining systems.

58 GEOSCIENCES↗

Multi-Scale Simulation of Wind Farm Performance during a Frontal Passage

Predicting the response of wind farms to changing flow conditions is necessary for optimal design and operation. Here in this work, simulation and analysis of a frontal passage through a utility scale wind farm is achieved for the first time using a seamless multi-scale modeling approach. A generalized actuator disk (GAD) wind turbine model is used to represent turbine–flow interaction, and results are compared to novel radar observations during the frontal passage. The Weather Research and Forecasting (WRF) model is employed with a nested grid setup that allows for coupling between multi-scale atmospheric conditions and turbine response. Starting with mesoscale forcing, the atmosphere is dynamically downscaled to the region of interest, where the interaction between turbulent flows and individual wind turbines is simulated with 10 m grid spacing. Several improvements are made to the GAD model to mimic realistic turbine operation, including a yawing capability and a power output calculation. Ultimately, the model is able to capture both the dynamics of the frontal passage and the turbine response; predictions show good agreement with observed background velocity, turbine wake structure, and power output after accounting for a phase shift in the mesoscale forcing. This study demonstrates the utility of the WRF-GAD model framework for simulating wind farm performance under complex atmospheric conditions.

17 WIND ENERGY↗

Linking the Dynamic Response of the Carbon Dioxide-Concentrating Mechanism to Carbon Assimilation Behavior in Fremyella diplosiphon

ABSTRACT Cyanobacteria use a carbon dioxide (CO 2 )-concentrating mechanism (CCM) that enhances their carbon fixation efficiency and is regulated by many environmental factors that impact photosynthesis, including carbon availability, light levels, and nutrient access. Efforts to connect the regulation of the CCM by these factors to functional effects on carbon assimilation rates have been complicated by the aqueous nature of cyanobacteria. Here, we describe the use of cyanobacteria in a semiwet state on glass fiber filtration discs—cyanobacterial discs—to establish dynamic carbon assimilation behavior using gas exchange analysis. In combination with quantitative PCR (qPCR) and transmission electron microscopy (TEM) analyses, we linked the regulation of CCM components to corresponding carbon assimilation behavior in the freshwater, filamentous cyanobacterium Fremyella diplosiphon . Inorganic carbon (C i ) levels, light quantity, and light quality have all been shown to influence carbon assimilation behavior in F. diplosiphon . Our results suggest a biphasic model of cyanobacterial carbon fixation. While behavior at low levels of CO 2 is driven mainly by the C i uptake ability of the cyanobacterium, at higher CO 2 levels, carbon assimilation behavior is multifaceted and depends on C i availability, carboxysome morphology, linear electron flow, and cell shape. Carbon response curves (CRCs) generated via gas exchange analysis enable rapid examination of CO 2 assimilation behavior in cyanobacteria and can be used for cells grown under distinct conditions to provide insight into how CO 2 assimilation correlates with the regulation of critical cellular functions, such as the environmental control of the CCM and downstream photosynthetic capacity. IMPORTANCE Environmental regulation of photosynthesis in cyanobacteria enhances organismal fitness, light capture, and associated carbon fixation under dynamic conditions. Concentration of carbon dioxide (CO 2 ) near the carbon-fixing enzyme RubisCO occurs via the CO 2 -concentrating mechanism (CCM). The CCM is also tuned in response to carbon availability, light quality or levels, or nutrient access—cues that also impact photosynthesis. We adapted dynamic gas exchange methods generally used with plants to investigate environmental regulation of the CCM and carbon fixation capacity using glass fiber-filtered cells of the cyanobacterium Fremyella diplosiphon . We describe a breakthrough in measuring real-time carbon uptake and associated assimilation capacity for cells grown in distinct conditions (i.e., light quality, light quantity, or carbon status). These measurements demonstrate that the CCM modulates carbon uptake and assimilation under low-C i conditions and that light-dependent regulation of pigmentation, cell shape, and downstream stages of carbon fixation are critical for tuning carbon uptake and assimilation.

59 BASIC BIOLOGICAL SCIENCES↗

Direct numerical simulation of supercritical oxy-methane mixing layers with CO 2 substituted counterparts

Direct numerical simulations (DNS) of temporally developing, three dimensional, CH 4 /CO 2 , CH 4 /O 2 and CO 2 /O 2 mixing layers, are conducted at a supercritical pressure of 300 atm. To effectively model the supercritical regime, the employed formulation includes the compressible form of the governing equations, the cubic Peng-Robinson equation of state and a generalized formulation for heat and mass flux vectors derived from non-equilibrium thermodynamics and fluctuation theory. A linear inviscid stability analysis is also performed for each case, to determine its most unstable wavelength. Flow visualizations reveal the presence of high density gradient magnitude regions for all three mixing layers, with conditional averages indicating increased presence of heavier fluid species within these regions. No significant departures are observed from perfect gas behavior, with compressibility factors very close to unity for all three mixing cases. Applicability of presumed probability density function methods (PDF) is examined for the three supercritical mixing layers. An a priori analysis is also conducted to investigate various simplifying assumptions employed in modeling various subgrid scale (SGS) flux models. Two additional terms are identified in the large eddy simulations (LES) equations, the gradient of SGS contribution of pressure in the momentum equation and the gradient of SGS contribution of heat flux in energy equation, whose magnitudes are similar and comparable with their respective resolved terms. The performance of the scale similarity model to represent these additional terms is investigated. Lastly, the performance of Smagorinsky, gradient and scale similarity models are also investigated.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Economic, Exergy, and Environmental Analyses of the Energy Assessments for U.S. Industries

Abstract This paper highlights the expected versus actual outcomes of 152 energy assessments that were performed between 2011 and 2020. The 1317 energy-assessment recommendations (ARs) are grouped into eight categories. This study adopted four measures per each category of recommendations: annual electricity savings, annual gas savings, annual cost savings, and annual CO2 emission reduction. The first part of the analysis compares the expected to the actually implemented values of the measures applied to each recommendation’s category. It was found that the percentages of the actual to the expected electricity, gas, and cost savings are 26.6%, 11.4%, and 17.1%, respectively, while the percentage of the actual to the expected CO2 reduction is 22%. Moreover, the second part of the analysis presents each category's implementation rate and the reasons for rejecting the unimplemented ARs. Cash flow and expensive initial investment resulted in rejecting 25% of ARs. Furthermore, the study proposes techniques and strategies to increase ARs’ implementation rate and improve private energy services companies’ implementation rate. Finally, exergy analysis is added to show the improvement that energy assessment achieves regarding exergy and exergy efficiencies of different industrial applications.

Energy & Fuels↗

"Hall" transport of liquid crystal solitons in Couette flow

Topology establishes a unifying framework for a diverse range of scientific areas including particle physics, cosmology, and condensed matter physics. One of the most fascinating manifestations of topology in the context of condensed matter is the topological Hall effect, and its relative: the Skyrmion Hall effect. Skyrmions are stable vortex-like spin configurations in certain chiral magnets, and when subject to external electric currents can drift in the transverse direction to the current. These quasi-particles are characterised by a conserved topological charge which in the Skyrmion Hall effect plays the role of electric charges in the ordinary Hall effect. Recently, it has been shown that liquid crystals endowed with chiral properties serve as an ideal testbed for the fundamental investigation of topological solitons, including their two- and three-dimensional realisations. Here, we show experimentally and numerically that three-dimensional solitons aka "torons" exhibit a Hall-like effect when driven by shear flows: the torons are deflected in the direction perpendicular to the shear plane. The experimental results are rationalised in terms of the dynamic Ericksen-Leslie equations, which predict the emergence of the transverse component of the net mass flow, the magnitude of which scales as the 3rd power of the shear rate. The perturbation analysis highlights an interplay of the viscous and chiral elastic torques as the mechanism for the emergence of net transverse currents. Numerical simulations demonstrate, however, that torons are not merely dragged by the flow but move with their own transverse speed, much larger than the average flow velocity in the transverse direction. Our findings may enable responsive microfluidic applications relying on soft topological solitons.

FOS: Physical sciences↗

Toward reducing uncertainty quantification costs in DEM models of particulate flow: Testing simple, sensitivity-based, forward uncertainty propagation techniques

The performance of two conceptually-simple uncertainty quantification techniques are tested against the rigorous nested-loop sampling technique of Roy and Oberkampf (Comput Methods Appl Mech Eng, 200: 2131–2144, 2011) (herein called full-sampling) using two very small-scale DEM-based models of particulate flow (one gas-solid flow and one granular flow). The first simplified forward uncertainty propagation technique, reduced-sampling, uses a sensitivity analysis to eliminate uncertain inputs that have little impact on the model output prior to nested-loop sampling. The second technique, boundary-sampling, uses a sensitivity analysis to inform the selection of two bounding cases for each key model output. In conclusion, the uncertainties in the model outputs obtained via the reduced- and boundary-sampling methods agree well with those from full-sampling for both the gas-solid and granular flow models while yielding computational savings of 65–75% (reduced sampling) and 94–97% (boundary sampling).

42 ENGINEERING↗

The Effect of Flow on CO2 Corrosion of Self-Healing Metallic Coatings

Internal corrosion is an issue that affects natural gas pipelines, a significant part of the United States’ energy infrastructure. Over time, this corrosion has worn away longstanding pipelines due to the original construction materials used for the lines and impurities in the gas and liquid streams flowing through them. The main impurities in natural gas are H2O, CO2, H2S, and O2. One of the leading causes of corrosion is the CO2 dissolved in water, giving rise to carbonic acid formation, which can further dissolve the steel pipe. The National Energy Technology Laboratory (NETL) has been studying different solutions to this problem. One potential answer is a self-healing sacrificial metallic coating applied by a novel cold spray technique. This study explored the impact of flow on corrosion with this coating and carbon steel when exposed to a saturated CO2 environment by simulating the pipeline flow profile in a small-scale lab setting. The samples were evaluated using multiple electrochemical techniques that found corrosion rates and were backed up with surface analysis to conclude the behavior of the corrosion mechanisms. The cold spray coating exhibited steel corrosion protection under flow conditions. This study has significantly advanced our understanding of CO2 corrosion, particularly in the context of natural gas pipelines and coating design.

carbon steel↗

A knowledge gap analysis for transient CHF prediction within RELAP5-3D

Here we compare several experimental pool and flow boiling critical heat flux experiments with corresponding computational models developed with RELAP5-3D. Encompassed within this paper are several sensitivity analyses for the boiling heat transfer correlations, critical heat flux (CHF) prediction within RELAP5-3D and the thermal properties of the cladding for experiments in the Transient Reactor Test Loop (TRTL) and Transient Reactor Test (TREAT) facilities. The sensitivity analyses were consistent in determining that there is a large contribution from the critical heat flux multiplier which in this application, accounts for the effects of power transient critical heat flux. Comparison to experimental results of both the TREAT CHF-SERTTA experimental campaign and a University of New Mexico (UNM) pool boiling experimental campaign demonstrate both the under-prediction of transient CHF and nucleate boiling heat transfer. To address the gaps in knowledge regarding the transient heating effect for both boiling heat transfer and CHF prediction, we present an experimental test matrix for the TRTL facility that will isolate the power transient effect under PWR relevant operational conditions. The test matrix will incorporate 6 power pulses with a constant energy deposition and a timescale that spans over several orders of magnitude, including a steady state test with an exponential period of 10 s.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Field Validation of Thermoelectric Generation System at Holcim Cement Plant in Alpena, Michigan

Executive Summary Project Background The Industrial Technology Validation (ITV) program aims to identify and demonstrate the performance of new, emerging, and underutilized energy-saving technologies in the industrial sector to help inform decisions to help accelerate their commercialization and deployment, as well as to help make industries more competitive. This ITV demonstration evaluated a thermoelectric generation (TEG) technology at a cement plant, aiming to reduce energy demand in the cement industry. A median cement plant consumes 5.73 million British thermal units per ton of clinker production (resulting in 0.838 metric tons of carbon dioxide [CO₂] emissions per ton of clinker) (Boyd and Zhang 2011, EPA 2021), equivalent to approximately 6.9 trillion British thermal units (TBtu) per year in energy consumption at a cement plant producing 3,300 tons of clinker per day.¹ Collaborating with Holcim, Advanced Thermovoltaic Systems (ATS) developed and deployed a pilot-scale thermoelectric power system to efficiently capture and convert waste heat to electricity. The system leverages the Seebeck effect to convert temperature differences on two sides of semiconductor cartridges into electrical power (ScienceDirect, n.d.). This generation is realized with minimal moving parts compared to existing waste-heat-to-generation solutions and allows capture from heat sources with temperatures as low as 150°C. This project aimed to validate a scalable solution applicable for capturing medium-temperature waste heat, including ambient losses from other high-temperature processes, and high-temperature sources less suitable for other waste-heat-to-power solutions. By recovering this otherwise wasted heat, this project intends to validate improvements to overall process efficiency through reduction in purchased electricity, thereby reducing operational costs while enhancing resiliency and competitiveness. Description and Scope This study evaluated the performance of a TEG system from ATS as a solution to convert waste heat into useful power at a Holcim cement plant in Alpena, Michigan. This plant is a fully integrated cement plant that has been operating since 1907. The facility operates continuously (24/7/365) with approximately 250 employees and five long dry kilns, yielding a total production capacity of 7,852 tons of cement per day (EPA 2023). Currently, the Alpena plant uses waste heat boilers to convert waste heat from the exhaust of each kiln into steam, which drives steam turbine generators. The ATS TEG is being evaluated for its potential to supplement the steam turbines by capturing the remaining lower grade heat. This technology is also being considered for other Holcim plants where steam turbines are not a viable option. ATS installed a pilot-scale TEG unit with an array of 582 individual thermoelectric semiconductor cartridges, of which 573 were operational. The cartridges are sandwiched between 48 hot plates and 49 cold plates. Each cartridge is designed to generate 20 watts (W) of gross power at a hot-side temperature of 240°C and cold-side temperature of 20°C. As such, the total gross generation capacity of the installed system is 11.5 kilowatts (kW) at design conditions. The system configuration for the evaluation was designed to prioritize convenience of installation and minimize disruption to production at the site, while ensuring that the heat required can be obtained for evaluating the TEG system at various operational conditions. To accomplish this, a portion of the steam supplied to Alpena’s steam turbine generation system was diverted to be used as the heat source for the TEG system, while water was supplied to the cold side of the system from nearby Lake Huron. This configuration was designed for the evaluation of the pilot-scale system to assess the performance at different conditions. A commercial-scale system will likely vary from the pilot system depending on typical configurations, including both scale and application. Future commercial applications of the ATS system would involve integrating the system into the exhaust from kiln preheaters, clinker coolers, or radiant heat capture from kiln shells for the heat source. For the cold source, a range of cooling solutions can be considered, including a mechanical cooling system, depending on the location and the application. To increase the generation capacity for commercial applications, the technology provider is working toward developing a commercial-scale TEG system, which would combine multiple TEG units (each similar in design to the pilot system) together. The scope of this evaluation includes the pilot-scale TEG system and all impacted equipment including pumps, controllers, and power handling equipment. Study Objectives The evaluation's goal was to assess the potential of the ATS TEG system to generate useful electrical power by capturing waste heat from cement production kilns. The objectives of this study are to evaluate and verify the following claims made by ATS regarding the pilot-scale system installed at the Holcim Alpena plant. The following design parameters and claims are also outlined in Table ES- 1 and Table ES- 2: • Gross Power: The thermoelectric system converts heat into power to create gross power, the total measured power generated by the system. The 573 active cartridge pilot-scale system is expected to generate 11.5 kW of gross power at the designed hot-side temperature of 240°C and cold-side temperature of 20°C. Power production is dependent on the temperature difference between the heat source (ultimately from the waste heat) and cold temperature supply source. • Net Power: The net power is the total usable power provided to the site by the TEG system after deducting parasitic power loads from the gross generated power. Supplementary equipment is required to operate the TEG system including pumps, controllers, and, in certain anticipated applications, mechanical cooling, which introduce parasitic loads to system operation. After deducting the parasitic loads from the gross power generation, ATS anticipates achieving a net power generation of 7.5 kW from the pilot-scale system. • Thermal Efficiency: The thermal efficiency is the percent of the total heat transferred to the TEG system that is converted to gross power. Historically, TEGs have a thermal efficiency of 2%–5% (DOE 2008). Prior industrial-scale TEG systems, such as the E1 TEG offered by Alphabet Energy, operated at an efficiency of 2.5% (Lamonica, 2014). ATS anticipates achieving an average efficiency of 4.8% or higher in converting heat energy to usable electricity. • Cartridge Performance: The TEG system comprises 573 active individual semiconductor cartridges, each of which generates a portion of the total power. Cartridge optimization and selection is an important design consideration for potential future TEG system design performance. Therefore, understanding the distribution of gross power and efficiency within the pilot system is vital to understanding what is achievable. At a design hot-side temperature of 240°C and cold-side temperature of 20°C, ATS anticipates a cartridge performance of 20 W of gross power per cartridge at an efficiency of 4.8% per cartridge. In addition to evaluating the claimed performance of the TEG pilot-scale unit, the study estimated the potential annual impacts of a scaled-up commercial system used to capture kiln waste heat over annual operations. The evaluation estimated the gross and net annual electric generation achievable by capturing heat from the two proposed tap-in points: the kiln exhaust and the clinker cooler exhaust; see Section 2.1 for details. Two use cases were examined: • Holcim Alpena: The Holcim Alpena site consists of long dry kilns with superheater boilers, which differs from the rest of Holcim’s cement plant portfolio and results in lower waste heat temperatures. The study estimates gross and net annual generation using the superheater boiler exhaust and clinker cooler exhaust, based on 2023 operational data. • Typical Installation: Common cement plants have preheater kilns with higher exhaust temperatures than Holcim Alpena across a range of production rates. The study estimates gross and net annual generation using the preheater exhaust and clinker cooler exhaust, with a sensitivity analysis to account for the typical range of preheater exhaust temperatures, clinker cooler exhaust temperatures, and clinker production rates. Methodology The evaluation methodology followed a measurement and verification (M&V) strategy based on the International Performance Measurement and Verification Protocol Option B through comprehensive measurements and analyses of the affected systems. Evaluation data was collected from March 9 to March 11, 2024, the test period of the pilot TEG system. During the test period, in coordination with the ITV team, the ATS team adjusted system operations to capture the range of variability expected for each of the variables pertinent to performance of the system. The methodology consisted of two parts: evaluating the performance of the pilot unit's TEG system and estimating the annual TEG impact in terms of gross and net power based on a given waste heat profile. First, the evaluation of the thermoelectric generation performance of the pilot unit relative to the claims was performed by analyzing the collected test data. Gross power of the pilot TEG system was directly measured. Net power was determined by deducting the measured parasitic power from the gross power. The gross power generation was compared to heat transferred to the system by the working fluid (which was heated by steam generated from the kiln waste heat) to calculate the thermal efficiency achieved by the system. Performance of individual semiconductor cartridges within the pilot array was also assessed in terms of measured gross cartridge power and calculated cartridge thermal efficiency. The second part of the evaluation estimated the annual TEG impacts in terms of gross power and net power (calculated from the difference between gross power and parasitic power). This analysis comprised development of mathematical regression models for gross power and parasitic power, with assessment of each model’s goodness-of-fit characteristics to ensure satisfaction of statistical requirements. The models predicted the gross power generation, the parasitic load based on the temperature difference between the hot working fluid and the cold-side fluid (cold water from Lake Huron) entering the system, the volumetric flow rate of the cold-side fluid at the inlet, and the volumetric flow rate of the hot working fluid at the inlet. The annual impact analysis considered a theoretical commercial-scale system sized to capture the available waste heat at a cement plant, consisting of linked pilot-scale units that receive heat from a theoretical gas-to-working-fluid heat exchanger. To estimate annual impacts at the Alpena plant, the gross power and parasitic power regression models were applied to the arrays in the theoretical commercial-scale system. The heat supplied to the unit was calculated based on the kiln run time, annual production, kiln exhaust waste heat, and clinker cooler waste heat derived from 2023 Holcim Alpena kiln operational data. Net power impacts were calculated by deducting the resulting parasitic power from the estimated gross power. Inputs for the model were generated from a combination of hourly data, assumed design considerations for TEG system scale-up from the pilot-scale unit, and assumptions regarding TEG system operations. This analysis was then used as the basis for estimating annual impacts of typical TEG installation at cement plants, by applying sensitivity analyses to key kiln operational characteristics including kiln preheater exhaust temperatures, cooler clinker exhaust temperatures, and plant daily production rates across a range of expected values. Project Results/Findings Table ES- 2 and Table ES- 2 provide a summary of the operating conditions and evaluation results compared to the stated claims from the technology provider. Key takeaways include: • Gross Power: The peak gross power achieved during the testing period was 10.0 kW, compared to the 11.5 kW expected for 573 active cartridges. The claimed gross power was associated with a target hot side of 240°C; however, the system only received a maximum hot-side mean plate temperature of 212°C during the testing period. • Net Power: The pilot-scale unit exceeded the claims for net power, achieving a peak of 7.7 kW net compared to a claim of 7.5 kW. One factor contributing to the higher achieved net power is the relatively high water pressure available through Lake Huron. The pilot TEG system did not require cold-side pumps during the test, whereas most installations would. This reduced the parasitic loads on the system, ultimately contributing to higher net power relative to the gross power. • Thermal Efficiency: The pilot-scale unit outperformed the claimed efficiency, achieving a peak system efficiency of 5.0% thermal efficiency compared to the stated 4.8%. • Cartridge Performance: To compare cartridge performance against claims, the study focused on the third day of testing, which aimed for conditions closest to the design specifications, with a hot side of 240°C and cold-side exit temperature of 6.4°–30°C. On this day, the mean gross power observed in the cartridges within the TEG array was 18.1 W/cartridge, and the peak performance was 34.7 W/cartridge. The estimated mean cartridge efficiency was 5.2%, and the estimated efficiency at peak gross cartridge power was 10%. The regression models developed for gross power generation and parasitic loads were used to estimate the generation impact for given heat input to the TEG from the working fluid (captured from the waste heat) and from the cold loop (Lake Huron) on an hourly basis for a year of operation. Based on this analysis, installation of a commercial-scale TEG system at the Holcim cement plant in Alpena, Michigan, with a waste heat exchanger of 0.85 effectiveness, would generate up to 391 kW of net power, translating to between 920,000 and 1,800,000 kilowatt-hours (kWh) in net electricity per year. Based on typical grid emissions for Alpena, this would avoid estimated net emissions by 752 metric tons of CO₂ annually.² The sensitivity analysis estimated that typical TEG system installations at cement plants could generate an average of 56–1,040 kW of net power, or between 488,000 and 9,110,000 kWh of net energy. This generation potential is most significantly affected by plant production rates and also influenced by preheater and clinker cooler exhaust temperatures. Applying the national average emission rate, typical commercial-scale installations at Holcim plants are projected to avoid between 182 and 3,401 metric tons of CO₂ annually per site. Table ES- 3 shows a summary of the estimated annual impacts.³ While parasitic loads are significant and vary by application, this analysis assumed the use of heating loop pumps and access to Lake Huron as a cold sink. This setup assumed no need for cooling loop pumps due to the available water pressure at the test site. Applications that require cooling towers or additional equipment are likely to experience higher parasitic loads. Therefore, the study’s estimates are most applicable to scenarios with similar parasitic load configurations—namely, access to a high-pressure cold sink. Applicability to other locations may be limited, as differing conditions could necessitate additional pumps and cooling systems, potentially impacting performance significantly.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Lagrangian analysis for turbulent transport in variable-density turbulence

In this report Lagrangian analysis of materially conserved scalars is applied to the problem of turbulent transport in variable-density flows. The consequences of an additional material conserved quantity, the density, is generally not acknowledged and leads to significant and meaningfully different expressions for turbulent transport in the moment equations. The formal Lagrangian analysis produces gradient transport expressions substantially different from those obtained by the physically intuitive “argument by analogy” method used in computational models. Various intuitive arguments, in Favre and Reynolds averaged settings, are contrasted to the formal Lagrangian results. Using expressions from the formal analysis, we derive consistent gradient transport closures for the turbulent transport terms that appear in the first- and second-order Favre moment equations. Results for coupled multispecies turbulent transport are given. The analysis is limited to variable-density turbulence in which the dilatation of the fluctuating velocity is small. The results are applicable to turbulent combustion and to stellar convection problems in which the density fluctuations are on the order of the mean density.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

CO2 Handling & Electrolyzer Efficiency Scaling Evaluator

CHEESE is an interactive dashboard tool for estimating the performance and material requirements of carbon dioxide electrolysis systems. It helps users evaluate how electrode area, current density, product selectivity, gas flow, cell voltage, and the number of cells in a stack affect system operation. The dashboard provides simple and advanced modes so it can be used for both quick estimates and more detailed engineering analysis. Users can estimate product output, carbon dioxide use, electrical power, electrode area, gas and liquid flow rates, energy efficiency, material cost per test, and the effect of scaling from a single cell to a multi cell stack. It also includes tools for examining carbon balance, equipment durability, component replacement, and changes in performance over time. This is intended to help both academia and industry researchers who are either getting into CO2 electrolysis on lab-scale or are trying to establish a larger footprint. CHEESE presents results through tables, charts, and simplified cell and stack diagrams. It is intended to support research planning, experimental design, comparison of operating conditions, and early stage scale up studies.

Prajapati, Aditya [Lawrence Livermore National Lab↗

MRT 7365: Power flow physics and key physics phenomena

The Z accelerator at Sandia National Laboratories conducts z-pinch experiments at 26 MA in support of DOE missions in stockpile stewardship, dynamic materials, fusion, and other basic sciences. Increasing the current delivered to the z-pinch would extend our reach in each of these disciplines. To achieve increases in current and accelerator efficiency, a fraction of Z’s shots are set aside for research into transmission-line power flow. These shots, with supporting simulations and theory, are incorporated into this Advanced Diagnostics milestone report. The efficiency of Z is reduced as some portion of the total current is shunted across the transmission-line gaps prior to the load. This is referred to as “current loss”. Electrode plasmas have long been implicated in this process, so the bulk of dedicated power-flow experiments are designed to measure the plasma environment. The experimental analyses are enhanced by simulations conducted using realistic hardware and Z voltage pulses. In the same way that diagnostics are continually being improved for sensitivity and resolution, the modeling capability is continually being improved to provide faster and more realistic simulations. The specifics of the experimental hardware, diagnostics, simulations, and algorithm developments are provided in this report. The combined analysis of simulation and data confirms that electrode plasmas have the most detrimental impact on current delivery. Experiments over the last three years have tested the theoretical current-loss mechanisms of enhanced ion current, plasma gap closure, and Hall-related current. These mechanisms are not mutually exclusive and may be coincident in the final feed as well as in upstream transmission lines. The final-feed geometries tested here, however, observe lower-density plasmas without dominant ion currents which is consistent with a Hall-related current. The picture of plasma formation and transport formed from experiment and simulation is informing hardware designs being fielded on Z now and being proposed for the Next-Generation Pulsed Power (NGPP) facility. In this picture, the strong magnetic fields that heat the electrodes above particle emission thresholds also confine the charged particles near the surface. Some portion of the plasmas thus formed is transported into the transmission-line gap under the force of the electric field, with aid from plasma instabilities. The gap plasmas are then transported towards the load by a cross-field drift, where they accumulate and contribute to a likely Hall-related cross-gap current. The achievements in experimental execution, model validation, and physical analysis presented in this report set the stage for continued progress in power flow and load diagnostics on Z. The planned shot schedule for Z and Mykonos will provide data for extrapolation to higher current to ensure the predicted performance and efficiency of a NGPP facility.

43 PARTICLE ACCELERATORS↗