Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “fixed source”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 865 records · Page 48

MapX: 2D XRF for Planetary Exploration - Image Formation and Optic Characterization

Map-X is a planetary instrument concept for 2D X-Ray Fluorescence (XRF) spectroscopy. The instrument is placed directly on the surface of an object and held in a fixed position during the measurement. The formation of XRF images on the CCD detector relies on a multichannel optic configured for 1:1 imaging and can be analyzed through the point spread function (PSF) of the optic. The PSF can be directly measured using a micron-sized monochromatic X-ray source in place of the sample. Such PSF measurements were carried out at the Stanford Synchrotron and are compared with ray tracing simulations. It is shown that artifacts are introduced by the periodicity of the PSF at the channel scale and the proximity of the CCD pixel size and the optic channel size. A strategy of sub-channel random moves was used to cancel out these artifacts and provide a clean experimental PSF directly usable for XRF image deconvolution.

47 OTHER INSTRUMENTATION↗

Experimental comparison of seven commercial dosimetry diodes for measurement of stereotactic radiosurgery cone factors

Purpose: The purpose of this work is to assess the variation in performance of various commercially available dosimetry diodes for quantitative small field dosimetry, specifically by intercomparing measurements of SRS cone factors. Methods: Measurements were made in 6 MV photon beams with fixed SRS cones for two accelerator-based SRS systems: a Varian Clinac iX (Varian/Zmed cones) at 600 MU/min and a CyberKnife model G4 at 800 MU/min. Measurements were made at 1.5 cm depth in water using the IBA Dosimetry ''blue phantom'' 3D scanning system, controlled by omnipro-accept software. Source-to-detector distance was 100 cm for the Clinac, 80 cm for the CyberKnife. Two normalization methods were used for the Clinac, one directly referenced to diode measurements in a 10 cm x 10 cm square field and the other indirectly by ''daisy-chaining'' diode measurements to ion chamber measurement in the 10 cm x 10 cm reference field through an intermediate 4 cm x 4 cm square field. CyberKnife factors were referenced directly to measurements in the 60 mm reference field. Seven commercial diodes were evaluated: PTW TN60008, TN60012, TN60016, TN60017; IBA Dosimetry SFD; Sun Nuclear EDGE; Exradin SD1 (first generation prototype). Results: With the exception of the SFD, all the evaluated devices yielded surprisingly consistent results. Standard deviations of Clinac factors for four diodes (SD1, EDGE, TN60008, and TN60012) ranged from approximately 0.50% at 30 mm to 2.0% at 5 mm cones size when referenced directly to the 10 cm x 10 cm measurement. The daisy-chaining strategy reduced the standard deviation to approximately 0.30% at 30 mm and 1.9% at 5 mm. Standard deviations for the same four diodes in the CyberKnife beam ranged up to approximately 1.0% at 5 mm. Conclusions: The inter-detector variation is small and appears to be systematic with detector packaging, more inherent filtration producing flatter curves for both the relatively hard Clinac beam and the softer CyberKnife beam. The daisy-chain strategy appears to be of limited value for most of the diodes, but does bring the SFD results into significantly better agreement with the others.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Web Extensible Display Manager 2

The Web Extensible Display Manager (WEDM) was first deployed at Jefferson Lab (JLab) in 2016 with the goal of rendering Extensible Display Manager (EDM) control screens on the web for the benefit of accessibility, and with version 2 our aim is to provide a more general purpose display toolkit by freeing ourselves from the constraints of the EDM dependency. Over the last few years WEDM has been extensively used at JLab for 24/7 information kiosks, on-call monitoring, and by remote users and staff. The software has also been deployed to Oak Ridge National Laboratory, and has become more robust as many bug fixes and contributions have been added. However, adoption and utility of the software as a general purpose control system display manager is limited by EDM, which is no longer actively maintained. A new toolkit can be built on modern frameworks, fully embrace web conventions and standards, and support multiple control system data sources. This new version is a result of a technology review and selection, and introduces a web inspired display file format, a web based display builder, new widgets, and a data interface intended to support pluggable data.

Slominski, R. J.↗

A study of algal biomass potential in selected Canadian regions.

A dynamic assessment model has been developed for evaluating the potential algal biomass and extracted biocrude productivity and costs, using nutrient and water resources available from waste streams in four regions of Canada (western British Columbia, Alberta oil fields, southern Ontario, and Nova Scotia). The purpose of this model is to help identify optimal locations in Canada for algae cultivation and biofuel production. The model uses spatially referenced data across the four regions for nitrogen and phosphorous loads in municipal wastewaters, and CO{sub 2} in exhaust streams from a variety of large industrial sources. Other data inputs include land cover, and solar insolation. Model users can develop estimates of resource potential by manipulating model assumptions in a graphic user interface, and updated results are viewed in real time. Resource potential by location can be viewed in terms of biomass production potential, potential CO{sub 2} fixed, biocrude production potential, and area required. The cost of producing algal biomass can be estimated using an approximation of the distance to move CO{sub 2} and water to the desired land parcel and an estimation of capital and operating costs for a theoretical open pond facility. Preliminary results suggest that in most cases, the CO{sub 2} resource is plentiful compared to other necessary nutrients (especially nitrogen), and that siting and prospects for successful large-scale algae cultivation efforts in Canada will be driven by availability of those other nutrients and the efficiency with which they can be used and re-used. Cost curves based on optimal possible siting of an open pond system are shown. The cost of energy for maintaining optimal growth temperatures is not considered in this effort, and additional research in this area, which has not been well studied at these latitudes, will be important in refining the costs of algal biomass production. The model will be used by NRC-IMB Canada to identify promising locations for both demonstration and pilot-scale algal cultivation projects, including the production potential of using wastewater, and potential land use considerations.

02 PETROLEUM↗

Dark Energy Survey Year 1 Results: Cross-correlation between DES Y1 galaxy weak lensing and SPT+Planck CMB weak lensing

We cross-correlate galaxy weak lensing measurements from the Dark Energy Survey (DES) year-one (Y1) data with a cosmic microwave background (CMB) weak lensing map derived from South Pole Telescope (SPT) and Planck data, with an effective overlapping area of 1289 deg$^{2}$. With the combined measurements from four source galaxy redshift bins, we reject the hypothesis of no lensing with a significance of $10.8\sigma$. When employing angular scale cuts, this significance is reduced to $6.8\sigma$, which remains the highest signal-to-noise measurement of its kind to date. We fit the amplitude of the correlation functions while fixing the cosmological parameters to a fiducial $\Lambda$CDM model, finding $A = 0.99 \pm 0.17$. We additionally use the correlation function measurements to constrain shear calibration bias, obtaining constraints that are consistent with previous DES analyses. Finally, when performing a cosmological analysis under the $\Lambda$CDM model, we obtain the marginalized constraints of $\Omega_{\rm m}=0.261^{+0.070}_{-0.051}$ and $S_{8}\equiv \sigma_{8}\sqrt{\Omega_{\rm m}/0.3} = 0.660^{+0.085}_{-0.100}$. These measurements are used in a companion work that presents cosmological constraints from the joint analysis of two-point functions among galaxies, galaxy shears, and CMB lensing using DES, SPT and Planck data.

79 ASTRONOMY AND ASTROPHYSICS↗

Comparison of the MCNP6 and FLUKA Codes in Shielding Calculation at ProNova Proton Therapy Facility

The Monte Carlo method is a powerful tool to simulate particle transport in materials, and can be effectively used to design radiation shielding. The purpose of this study is to compare the results from two Monte Carlo codes (MCNP6 and FLUKA ) in shielding design. The calculation was also compared with the measured results from the ProNova Superconducting 360 degrees (SC360) installation at the Knoxville Provision Center for Proton Therapy (PCPT) facility. The SC360 230 MeV continue wave (CW) proton beam is produced by an isochronous cyclotron, the Sumitomo P235. The maximum beam that is extracted into the beamline is 300 nA, which is of 60% of the full current generated in cyclotron. The SC360 facility has an energy selection system for adjusting the proton range, one fixed beam and one gantry room for rotating the beam around the stationary patient. At the entrance to each treatment room beamline, a thickness adjustable Beryllium degrader inserted in the beam path is used to achieve the desirable beam energy. When protons interact with beamline components, the secondary neutrons become the dominant source to determine the radiation shielding. In this study, the dose rate outside the lateral wall of the beamline vault was discussed. The calculations from two Monte Carlo codes were compared and they agreed very well. The dose rates measured by a Wendi-II Neutron Detector agreed within a factor of less than seven compared with the calculation results. The difference may be explained by a variety of factors such as the uncertainty in knowing the exact composition of shielding materials, geometry difference, and the measurement uncertainty due to instrumentation. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

Optimization of Air Electrode for Li/Air Batteries

The effects of carbon microstructure and carbon loading on the performance of Li/air batteries were investigated. The active carbons from various sources were compared, and a dry rolling method was optimized to prepare air electrodes with high mesopore volume. It is found that the capacities of air electrodes improve significantly when the mesopore volume of the carbon source is high. However, for carbons with low mesopore volumes, other factors such as surface activity also play an important role in determining the electrochemical performances of the Li/air batteries. A practical criterion, area-specific capacity, was used to optimize the carbon loading for air electrode. The best area-specific capacity of 13.1 mAh/cm2 was obtained at a carbon loading of 15.1 mg/cm2. Further increasing or decreasing the carbon loading led to a reduced area- specific capacity. Finally, at fixed carbon loading and discharge rates, electrolyte amount was another key factor governing cell performance. A spring mechanism is proposed to explain the formation of the tri-phase regions in air electrodes. After optimizing the parameters listed above, a high capacity of 1,756 mAh/g carbon corresponding to a specific energy of 4,614 Wh/kg carbon was obtained for Li/air batteries operated in a dry air environment.

25 ENERGY STORAGE↗

TH-AB-207A-09: Tailoring TCM Schemes to a Task: Evaluating the Impact of Customized TCM Profiles On Detection of Lung Nodules in Simulated CT Lung Cancer Screening

Purpose: Recent work has shown that current TCM profile designs boost detection of low-contrast lung lesions in the lung apices, but yield reduced detection performance in the mid and lower lung regions relative to fixed tube current cases. This observed imbalance suggests that the TCM scheme might be tailored in new ways to maximize nodule detection throughout the entire lung. In this work, we begin a preliminary investigation into custom TCM profiles in an attempt to achieve uniform lesion detection throughout the extent of the lung. Methods: Low-contrast (25HU), 6mm nodules representing ground glass opacities were simulated at 1mm intervals over the length the lungs in a voxelized model of the XCAT phantom, one nodule per lung, per simulated scan. Voxel values represented attenuation values at 80keV. CT projection data was created by simulating a finite focal spot and using Joseph’s method for forward projection; scanner geometry was that of the Siemens Sensation 64 and the X-ray source was simulated as an 80keV monochromatic beam. Noise realizations were created using Poisson statistics, a realistic bowtie filter and varying tube current. 500 noise realizations were created for the custom TCM designs. All reconstruction was done with FreeCT-wFBP. An SKE/BKE task was used in conjunction with a 2D Hotelling Observer to calculate area-under-the-curve (AUC) as a proxy for “detectability.” AUC was plotted as a function of nodule Z-location to create a “detectability map.” The detectability map for the custom TCM curve was qualitatively assessed relative to previous results for the fixed TC and clinical TCM cases for uniformity. Results: Detection uniformity was improved throughout the mid and lower lungs, however detection remained disproportionately high in the upper lung region. Conclusion: Detection uniformity was improved with a custom TC profile. Future work will incorporate an analytic, task-specific approach to optimize the TC scheme for nodule detection. J. Hoffman: Part-time intern, Toshiba Medical Research Institute; M. McNitt-Gray: Institutional research agreement, Siemens Healthcare; Past recipient, research grant support, Siemens Healthcare; Consultant, Toshiba America Medical Systems; Consultant, Samsung Electronics; F. Noo: Institutional research agreement, Siemens Healthcare; Receives research funding from Siemens Healthcare.

60 APPLIED LIFE SCIENCES↗

Merger-driven fueling of active galactic nuclei: Six dual and of AGNs discovered with Chandra and Hubble Space Telescope observations

Dual active galactic nuclei (AGNs) and offset AGNs are kpc-scale separation supermassive black holes pairs created during galaxy mergers, where both or one of the black holes are AGNs, respectively. These dual and offset AGNs are valuable probes of the link between mergers and AGNs but are challenging to identify. Here we present Chandra/ACIS observations of 12 optically selected dual AGN candidates at z<0.34, where we use the X-rays to identify AGNs. We also present Hubble Space Telescope/Wide Field Camera 3 observations of 10 of these candidates, which reveal any stellar bulges accompanying the AGNs. We discover a dual AGN system with separation Δx=2.2 kpc, where the two stellar bulges have coincident [O iii] λ5007 and X-ray sources. This system is an extremely minor merger (460:1) that may include a dwarf galaxy hosting an intermediate mass black hole. We also find six single AGNs, and five systems that are either dual or offset AGNs with separations Δx<10 kpc. Four of the six dual AGNs and dual/offset AGNs are in ongoing major mergers, and these AGNs are 10 times more luminous, on average, than the single AGNs in our sample. This hints that major mergers may preferentially trigger higher luminosity AGNs. Further, we find that confirmed dual AGNs have hard X-ray luminosities that are half of those of single AGNs at fixed [O iii] λ5007 luminosity, on average. This could be explained by high densities of gas funneled to galaxy centers during mergers, and emphasizes the need for deeper X-ray observations of dual AGN candidates.

79 ASTRONOMY AND ASTROPHYSICS↗

Recycler lattice for Project X at Fermilab

Project X is an intense proton source that provides beam for various physics programs. The source consists of an 8 GeV H- superconducting linac that injects into the Fermilab Recycler where H- are converted to protons. Protons are provided to the Main Injector and accelerated to desired energy (in the range 60-120 GeV) or extracted from the Recycler for the 8 GeV program. A long drift space is needed to accommodate the injection chicane with stripping foils. The Recycler is a fixed 8 GeV kinetic energy storage ring using permanent gradient magnets. A phase trombone straight section is used to control the tunes. In this paper, the existing FODO lattice in RR10 straight section being converted into doublet will be described. Due to this change, the phase trombone straight section has to be modified to bring the tunes to the nominal working point. A toy lattice of recycler ring is designed to simulate the end-shim effects of each permanent gradient magnet to add the flexibility to handle the tune shift to the lattice during the operation of 1.6E14 with KV distribution of the proton beam to give {approx}0.05 of space charge tune shift. The comparison or the combinations of the two modification ways for the Recycler ring lattice will be presented also in this paper.

43 PARTICLE ACCELERATORS↗

Energy Differential Response of Cancer Cells for Low Dose Irradiation:Impact of Monoenergetic Brachytherapy Sources

Purpose: The purpose of this work was to evaluate the energy differential response of cancer cells under identical dose exposure to asses the relevancy of mono-energetic sources for Brachytherapy treatments. Method and Materials: An electron energy spectrum impinging on lived breast cancer cell lines (MDA321) was obtained by placing a 19.65 {micro}Ci {sup 90}Sr/{sup 90}Y radioactive source in front of a non-uniform magnetic field constructed from two 5.08 x 5.0 cm x 2.54 cm neodimium ion permanent dipole magnets with a 1 cm separation gap. The cell lines were placed on the exit pole face of the magnet and were subsequently irradiated with different electron energies ranging from about 0.75 MeV to 1.85 MeV. The energy distribution was accurately measured with a scintillating fiber detector system that provided a 0.5% agreement with ICRU and a 5% energy resolution. The dosimetry was performed using a series of data acquired with a {sup 9}Sr/{sup 90}Y 4.5 mCi SIA-6 eye applicator, 6-21 MeV fixed energies from a Varian 2100 EX linac, EBT Gafchromic and Kodak ERT2 films, and an ion chamber detector. The accuracy of the dose rate obtained at different locations along and away from the magnet inside the cell containers was within 10.7%. Results: The cell lines were irradiated with a 0.5-4 Gy dose range. The data indicate a very strong differential energy response for electrons around 1 MeV (more lethal) compare to those with lesser or greater energy and a survival rate of at most 10% at very low dose (0.5-2 Gy). Conclusion: Mono-energetic Brachytherapy sources may provide a new pathway for radio-therapy treatment optimizations following a dedicated study showing very unusual high lethality in a specific energy window for MDA321 breast cancer cells.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

RELIABILITY BASED DESIGN OF FIXED FOUNDATION WIND TURBINES

Recent analysis of offshore wind turbine foundations using both applicable API and IEC standards show that the total load demand from wind and waves is greatest in wave driven storms. Further, analysis of overturning moment loads (OTM) reveal that impact forces exerted by breaking waves are the largest contributor to OTM in big storms at wind speeds above the operating range of 25 m/s. Currently, no codes or standards for offshore wind power generators have been adopted by the Bureau of Ocean Energy Management Regulation and Enforcement (BOEMRE) for use on the Outer Continental Shelf (OCS). Current design methods based on allowable stress design (ASD) incorporate the uncertainty in the variation of loads transferred to the foundation and geotechnical capacity of the soil and rock to support the loads is incorporated into a factor of safety. Sources of uncertainty include spatial and temporal variation of engineering properties, reliability of property measurements applicability and sufficiency of sampling and testing methods, modeling errors, and variability of estimated load predictions. In ASD these sources of variability are generally given qualitative rather than quantitative consideration. The IEC 61400‐3 design standard for offshore wind turbines is based on ASD methods. Load and resistance factor design (LRFD) methods are being increasingly used in the design of structures. Uncertainties such as those listed above can be included quantitatively into the LRFD process. In LRFD load factors and resistance factors are statistically based. This type of analysis recognizes that there is always some probability of failure and enables the probability of failure to be quantified. This paper presents an integrated approach consisting of field observations and numerical simulation to establish the distribution of loads from breaking waves to support the LRFD of fixed offshore foundations.

17 WIND ENERGY↗

Four-dimensional emittance measurement at the Spallation Neutron Source

A coasting hadron beam with an elliptical transverse profile, uniform charge density, and small transverse four-dimensional (4D) emittance could improve accelerator performance in several contexts. A phase space painting method to generate such a distribution is being tested in the Spallation Neutron Source (SNS) accumulator ring. A critical component of these efforts is to measure the 4D emittance of the beam during accumulation. The 4D emittance can be reconstructed from measured beam profiles in two ways: in the multi-optics method, the optics between a reconstruction and measurement location are varied; in the fixed-optics method, multiple measurement locations are used without modifying the optics. The fixed-optics method is faster but can lead to large uncertainty in the reconstructed 4D emittance. In this paper, we implement a variant of the multi-optics method using the four available wire-scanners near the SNS target. We also modify the wire-scanner region to reduce the uncertainty of the fixed-optics method. We then demonstrate the usefulness of the fixed-optics method by reconstructing the 4D emittance evolution during accumulation in the SNS ring.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Investigating the effects of electron bounce-cyclotron resonance on plasma dynamics in capacitive discharges operated in the presence of a weak transverse magnetic field

Recently, Patil et al. [Phys. Rev. Res. 4, 013059 (2022)] have reported the existence of an enhanced operating regime when a low-pressure (5 mTorr) capacitively coupled discharge (CCP) is driven by a very high radio frequency (60 MHz) source in the presence of a weak external magnetic field applied parallel to its electrodes. Their particle-in-cell simulations show that a significantly higher bulk plasma density and ion flux can be achieved at the electrode when the electron cyclotron frequency equals half of the applied radio frequency for a given fixed voltage. In the present work, we take a detailed look at this phenomenon and further delineate the effect of this “electron bounce-cyclotron resonance (EBCR)” on the electron and ion dynamics of the system. We find that the ionization collision rate and stochastic heating are maximum under resonance condition. The electron energy distribution function also indicates that the population of tail-end electrons is highest for the case where EBCR is maximum. Formation of electric field transients in the bulk plasma region is also seen at lower values of applied magnetic field. Finally, we demonstrate that the EBCR-induced effect is a low-pressure phenomenon and weakens as the neutral gas pressure increases. The potential utility of this effect to advance the operational performance of CCP devices for industrial purposes is discussed in this report.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The hydrogen molecule under the reaction microscope: single photon double ionization at maximum cross section and threshold (doubly differential cross sections)

In this paper, we studied the photo double ionization of hydrogen molecules in the threshold region (50 eV) and the complete photo fragmentation of deuterium molecules at maximum cross section (75 eV) with single photons (linearly polarized) from the Advanced Light Source, using the reaction microscope imaging technique. The 3D-momentum vectors of two recoiling ions and up to two electrons were measured in coincidence. We present the kinetic energy sharing between the electrons and ions, the relative electron momenta, the azimuthal and polar angular distributions of the electrons in the body-fixed frame. We also present the dependency of the kinetic energy release in the Coulomb explosion of the two nuclei on the electron emission patterns. We find that the electronic emission in the body-fixed frame is strongly influenced by the orientation of the molecular axis to the polarization vector and the internuclear distance as well as the electronic energy sharing. Finally, traces of a possible breakdown of the Born–Oppenheimer approximation are observed near threshold.

74 ATOMIC AND MOLECULAR PHYSICS↗

Dimensionally Aligned Signal Projection Algorithms Library

Dimensionally aligned signal projection (DASP) algorithms are used to analyze fast Fourier transforms (FFTs) and generate visualizations that help focus on the harmonics for specific signals. At a high level, these algorithms extract the FFT segments around each harmonic frequency center, and then align them in equally sized arrays ordered by increasing distance from the base frequency. This allows for a focused view of the harmonic frequencies, which, among other use cases, can enable machine learning algorithms to more easily identify salient patterns. This work seeks to provide an effective open-source implementation of the DASP algorithms proposed by Vann et al. (2018) as well as functionality to help explore and test how these algorithms work with an interactive dashboard and signal-generation tool. The DASP library is implemented in Python and contains four types of algorithms for implementing these feature engineering techniques: fixed harmonically aligned signal projection (HASP), decimating HASP, interpolating HASP, and frequency aligned signal projection (FASP). Each algorithm returns a numerical array, which can be visualized as an image. The HASP algorithms are variations of the algorithms originally presented by Vann et al. (2018). For consistency, FASP, which is the terminology used for the short-time Fourier transform (STFT), has been implemented as part of the library to provide a similar interface to the STFT of the raw signal. Additionally, the library contains an algorithm to generate artificial signals with basic customizations such as the base frequency, sample rate, duration, number of harmonics, noise, and number of signals. Finally, the library provides multiple interactive visualizations, each of which is implemented using IPyWidgets and works in a Jupyter environment. A dashboard-style visualization is provided, which contains some common signal-processing visual components (signal, FFT, spectogram) updating in unison with the HASP functions (see Figure 1 below). Separate from the dashboard, an independent visualization is provided for each of the DASP algorithms as well as for the artifical signal generator. These visualizations are included in the library to aid in developing an intuitive understanding how the algorithms are affected by different input signals and parameter selections.

harmonics↗

Strongly Tapered Helical Undulator System for Fast-greens Installation

RadiaBeam, in collaboration with UCLA and Fermilab, is developing a strongly tapered helical undulator system for the Tapering Enhanced Stimulated Superradiant Amplification experiment at 515 nm (TESSA-515). The experiment will be carried out at the FAST facility at Fermilab as a Gamma-Ray high Efficiency ENhanced Source (FAST-GREENS). The undulator system was designed by UCLA, engineered by RadiaBeam, and will be installed on the beamline at Fermilab (FNAL). The design is based on a permanent magnet Halbach scheme of four 1-meter long undulator sections; two of which have been completed and installed. The undulator period is fixed at 32 mm and the magnetic field amplitude can be tapered by tuning the gap along the interaction. Each magnet can be individually adjusted by 1 mm, offering up to 25% magnetic field tunability with a minimum gap of 5.58 mm. This paper discusses the design and engineering of the undulator system and the stage 0 installation status.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Experimental setup combining in situ hard X-ray photoelectron spectroscopy and real-time surface X-ray diffraction for characterizing atomic and electronic structure evolution during complex oxide heterostructure growth

We describe the next-generation system for in situ characterization of a complex oxide thin film and heterostructure growth by pulsed laser deposition (PLD) using synchrotron hard X-rays. The system consists of a PLD chamber mounted on a diffractometer allowing both real-time surface X-ray diffraction (SXRD) and in situ hard X-ray photoelectron spectroscopy (HAXPES). HAXPES is performed in the incident X-ray energy range from 4 to 12 keV using a Scienta EW4000 electron energy analyzer mounted on the PLD chamber fixed parallel with the surface normal. In addition to the standard application mode of HAXPES for disentangling surface from bulk properties, the increased penetration depth of high energy photoelectrons is used for investigation of the electronic structure changes through thin films grown deliberately as variable thickness capping layers. Such heterostructures represent model systems for investigating a variety of critical thickness and dead layer phenomena observed at complex oxide interfaces. In this new mode of operation, in situ HAXPES is used to determine the electronic structure associated with unique structural features identified by real-time SXRD during thin film growth. The system is configured for using both laboratory excitation sources off-line and on-line operation at beamline 33-ID-D at the Advanced Photon Source. We illustrate the performance of the system by preliminary scattering and spectroscopic data on oxygen vacancy ordering induced perovskite-to-brownmillerite reversible phase transformation in La 2/3 Sr 1/3 MnO 3 films capped with oxygen deficient SrTiO 3–δ (100) layers of varying thickness.

47 OTHER INSTRUMENTATION↗