Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “fibers”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 865 records · Page 48

Toluene adsorption and capacity regeneration using zeolite-based monolith and activated carbon fiber felt

Common adsorbents studied to remove volatile organic compounds (VOCs) from indoor air can release previously adsorbed VOCs back into the indoor space when the adsorbent is saturated or if the VOC concentration fluctuates. A durable adsorbent with a continuous regeneration strategy could prevent this recontamination of the indoor air and reduce adsorbent disposal waste. A deeper understanding of the adsorption and desorption behavior of VOC adsorbents is needed to create an efficient regeneration strategy. This study investigated the adsorption and thermal desorption behavior of toluene on two different adsorbents, (1) a zeolite-based adsorbent and (2) an activated carbon fiber (ACF) felt. Consistent adsorption behavior across a series of toluene concentrations was used to experimentally determine effective adsorption capacity. When the cumulative adsorption between thermal regeneration steps was maintained below the maximum effective capacity with 0% breakthrough, the zeolite-based adsorbent was found to effectively minimize passive desorption. The impact of regeneration feed conditions, such as inert, oxidizing, humidified air, on thermal desorption was examined. These conditions influenced desorption of the zeolite-based adsorbent but had minimal impact on the ACF felt adsorbent, which would lead to different regeneration schedules and methods for applications in buildings' heating, ventilation, and air conditioning (HVAC) systems.

Moses-DeBusk, Melanie [Oak Ridge National Laborato↗

Fiber-optic silicon Fabry–Perot interferometric bolometer with improved detection limit for magnetic confinement fusion

Fiber-optic bolometers (FOBs) intended for plasma radiation measurement in magnetically confined fusion have been previously developed using a silicon pillar that functions as both a Fabry–Perot interferometer (FPI) for temperature measurement and an absorber for the radiation. We report an FOB design that can significantly improve the detection sensitivity over earlier designs by engineering the absorber of the FOB. Our design uses the fact that, compared with a silicon pillar, a gold film with the same x-ray absorption thickness will show a much higher temperature rise from a given power density of the radiation. Therefore, the responsivity of an FOB can be improved by attaching a large gold disk to the silicon FPI as the absorber. We have developed a fabrication method for FOBs of such design and obtained an FOB with a 4-µm-thick, 0.6-mm-diameter gold disk attached to a 200-µm-diameter, 100-µm-thick silicon FPI. We have characterized the noise, responsivity, response time, and noise-equivalent power density (NEPD) and compared these with the earlier design where the absorber is mainly the silicon FPI itself. The experimental result suggests that the FOB with the gold disk achieves a responsivity of ∼2.8 mK/(W/m2) and a noise-equivalent-power-density of 0.13 W/m2, which are, respectively, more than nine times larger and six times smaller compared to the FOB using a previous design. Improved NEPD and good absorption over a broad frequency range will make the FOB more attractive for applications in magnetic-confinement fusion devices.

Uddin, Nezam↗

Efficient generation and extreme compression of multidimensional solitary states in molecular gas-filled hollow-core fibers driven by picosecond Yb lasers

We present an in-depth study on the impact of spatiotemporal Raman enhancement in molecular gas-filled hollow-core fibers (HCFs), demonstrating the efficient generation and post-compression of multidimensional solitary states (MDSS). Through different experimental scenarios—employing large-core HCFs filled with molecular gases (N 2 and N 2 O) and driven by high energy, sub-picosecond and picosecond Fourier transform-limited ytterbium laser pulses—this work leverages multimode propagation and enhanced spatiotemporal interactions to achieve significant spectral broadening and asymmetric redshift, contrasting sharply with self-phase modulation. Our findings reveal that, beyond the regime of maximum nonadiabatic molecular alignment, spatiotemporal nonlinear enhancement primarily governs spectral broadening for input pulse durations up to 1 ps. The process shows limited sensitivity to input pulse duration and the two investigated molecular gases (N 2 and N 2 O), with only subtle differences in broadening arising from their distinct Raman spectroscopic properties. Furthermore, post-compression of MDSS was achieved in various cases. Notably, using 7 mJ, 1 ps laser pulses, we generated 22 fs pulses with a 47% energy conversion efficiency of the input pulse energy. These results position MDSS as a powerful platform for generating high-energy, ultrashort pulses with tunable wavelengths, offering a robust solution for applications such as high harmonic generation.

47 OTHER INSTRUMENTATION↗

Instantaneous mesh load factor ( K γ ) measurements in a wind turbine gearbox using fiber-optic strain sensors

The mesh load factor, K γ , describes how loads are shared between planet gears and has become one of the key design challenges in modern wind turbine gearboxes. Planet load sharing directly impacts tooth root stresses, a critical driver of torque density and gearbox reliability. Experimental evaluation of K γ is typically performed from sun gear tooth root strain gauge measurements, which are complex. Furthermore, such measurements can only provide an average value of load sharing. The present study describes an alternative method to evaluate the mesh load factor in wind turbine gearboxes based on fiber-optic strain sensors installed on the outer surface of the fixed ring gear. We present the results of an extensive measurement campaign to evaluate this novel sensing solution installed on the input planetary stage of a 2-MW wind turbine gearbox at the National Renewable Energy Laboratory's Flatirons Campus (Colorado, USA). The number of strain sensors on the ring gear was selected as an integer multiple of the number of planets, which has enabled an instantaneous evaluation of the mesh load factor. The effect of operating conditions on the planet load-sharing behavior of the gearbox has been investigated. The mesh load factor measured for operating conditions close to rated was below 1.05, well below IEC 61400-4 standard requirements.

17 WIND ENERGY↗

Towards a fiber barrel detector for next-generation high-pressure gaseous xenon TPCs

Abstract The NEXT (Neutrino Experiment with a Xenon TPC) project is an international collaboration aimed at finding evidence of neutrinoless double beta decay using gaseous xenon. The current phase of the project involves the construction and operation of NEXT-100, which is designed to hold 100 kg of xenon at 15 bar and is expected to start commissioning in the first quarter of 2024. NEXT-HD will be a tonne scale experiment following NEXT-100 and will incorporate a symmetric design, with one cathode and two anodes. For this detector, the collaboration is considering to implement a barrel of wavelength-shifting fibers read-out by silicon photomultipliers to measure the energy of the particles interacting in the gaseous xenon. In this document, we will discuss the characteristics of this approach and provide an update on the related R&D efforts.

Instruments & Instrumentation↗

Evaluation of the response to electrons and pions in the scintillating fiber and lead calorimeter for the future electron-ion collider

The performance of the Baby Barrel Electromagnetic Calorimeter (Baby BCAL) — a small-scale lead-scintillating-fiber (Pb/ScFi) prototype of the GlueX Barrel Electromagnetic Calorimeter (BCAL) — was tested in a dedicated beam campaign at the Fermilab Test Beam Facility (FTBF). This study provides a benchmark for the Pb/ScFi component of the future Barrel Imaging Calorimeter (BIC) in the ePIC detector at the Electron-Ion Collider (EIC). The detector response to electrons and pions was studied at beam energies between 4 and 10 GeV, extending previous GlueX tests to a higher energy regime. The calibrated detector exhibits good linearity within uncertainties, and its electron energy resolution meets EIC requirements. The data further constrain the constant term in the energy resolution to below 1.9%, improving upon previous constraints at lower energies. Simulations reproduce key features of the electron and pion data within the limitations of the collected dataset and the FTBF test environment. Electron-pion separation in the test beam setup was analyzed using multiple methods, incorporating varying degrees of beam-related effects. The inclusion of longitudinal shower profile information enhanced the separation performance, underscoring its relevance for the full-scale BIC in ePIC. These results provide essential benchmarks for the Pb/ScFi section of the future BIC, validating detector simulations and guiding optimization strategies for electron-pion discrimination.

47 OTHER INSTRUMENTATION↗

Glass 3D Printing of Microfluidic Pressure Sensor Interrogated by Fiber-Optic Refractometry

This letter reports a novel fused silica microfluidic device with pressure sensing capability that is fabricated by integrated additive and subtractive manufacturing (IASM) method. The sensor consists of a capillary and a 3D printed glass reservoir, where the reservoir volume change under pressure manifests liquid level deviation inside the capillary, thus realizing the conversion between small pressure change into large liquid level variation. Thanks to the design flexibility of this unique IASM method, the proposed microfluidic device is fabricated with liquid-in-glass thermometer configuration, where the reservoir is sealed following a novel 3D printing assisted glass bonding process. And liquid level is interrogated by a fiber-optic sensor based on multimode interference (MMI) effect. This proposed microfluidic device is attractive for chemical and biomedical sensing because it is flexible in design, and maintains good chemical and mechanical stability, and adjustable sensitivity and range.

42 ENGINEERING↗

Mechanical and Corrosion Assessment of Friction Self-Piercing Rivet Joint of Carbon Fiber-Reinforced Polymer and Magnesium Alloy AZ31B

In the present work, thermoset carbon fiber–reinforced polymer (CFRP) was spot joined to magnesium alloy AZ31B by a friction self-piercing riveting (F-SPR) process. Lap shear tensile and cross-tension testing were used to evaluate the mechanical joint performance. An average lap shear tensile load of 5.18 kN was achieved, while an average of 2.81 kN was found from cross-tension testing. All F-SPR samples showed a pullout of AZ31B after mechanical testing, indicating good mechanical interlocking between the steel rivet and AZ31B. Corrosion potential was measured for each material to establish the galvanic corrosion characteristics. As expected, AZ31B was found to be the most active, while thermoset CFRP was the most noble. The steel rivet fell between the AZ31B (active) and the thermoset CFRP (noble). Salt fog corrosion testing (ASTM B-117) was performed to evaluate the corrosion performance of the uncoated F-SPR joint. With up to 200 h of exposure, the post-corroded F-SPR joint integrity retained 81.2% of the pre-exposure F-SPR joint strength with AZ31B pullout failure mode. From cross-sectional analysis of the F-SPR joint, extensive corrosion of AZ31B was observed at the joint and other exposure areas. However, steel rivet was not significantly corroded due to sacrificial anode effect by which AZ31B corroded first in the galvanic couple.

36 MATERIALS SCIENCE↗

MECHANICAL AND CORROSION ASSESSMENT OF FRICTION SELF-PIERCING RIVET JOINT OF CARBON FIBER-REINFORCED POLYMER AND MAGNESIUM ALLOY AZ31B

In the present work, thermoset carbon fiber–reinforced polymer (CFRP) was spot joined to magnesium alloy AZ31B by a friction self-piercing riveting (F-SPR) process. Lap shear tensile and cross-tension testing were used to evaluate the mechanical joint performance. An average lap shear tensile load of 5.18 kN was achieved, while an average of 2.81 kN was found from cross-tension testing. All F-SPR samples showed pull-out of AZ31B after mechanical testing, indicating good mechanical interlocking between the steel rivet and AZ31B. Corrosion potential was measured for each material to establish the galvanic corrosion characteristics. As expected, AZ31B was found to be the most active, while thermoset CFRP was the most noble. The steel rivet fell between the AZ31B (active) and the thermoset CFRP (noble). Salt fog corrosion testing (ASTM B-117) was performed to evaluate the corrosion performance of the uncoated F-SPR joint. With up to 200 h of exposure, the post-corroded F-SPR joint integrity retained 81.2% of the pre-exposure F-SPR joint strength with AZ31B pull-out failure mode. From cross-sectional analysis of the F-SPR joint, extensive corrosion of AZ31B was observed at the joint and other exposure areas. However, steel rivet was not significantly corroded potentially due to sacrificial anode effect by which AZ31B corroded first in the galvanic couple.

Lim, Yong Chae↗

Transcriptomic Data Sets for Zymomonas mobilis 2032 during Fermentation of Ammonia Fiber Expansion (AFEX)-Pretreated Corn Stover and Switchgrass Hydrolysates

The transcriptomes of Zymomonas mobilis 2032 were captured during the fermentation of ammonia fiber expansion (AFEX)-pretreated corn stover and switchgrass hydrolysates containing different concentrations of glucose and xylose. RNA samples were collected when Z. mobilis was fermenting glucose or xylose. Here, we present transcriptome sequencing (RNA-Seq) data obtained during separate phases of glucose or xylose consumption.

59 BASIC BIOLOGICAL SCIENCES↗

Wavelength domain spatial frequency modulation imaging: enabling fiber optic delivery and detection

Spatial frequency modulation imaging (SPIFI) provides a simple architecture for modulating an extended illumination source that is compatible with single pixel imaging. We demonstrate wavelength domain SPIFI (WD-SPIFI) by encoding time-varying spatial frequencies in the spectral domain that can produce enhanced resolution images, like its spatial domain counterpart, spatial domain (SD) SPIFI. However, contrary to SD-SPIFI, WD-SPIFI enables remote delivery by single mode fiber, which can be attractive for applications where free-space imaging is not practical. Finally, we demonstrate a cascaded system incorporating WD-SPIFI in-line with SD-SPIFI enabling single pixel 2D imaging without any beam or sample scanning.

47 OTHER INSTRUMENTATION↗

Low-loss adiabatic fiber-optic coupler for cryogenic photonics

Recent developments in quantum light–matter coupled systems and quantum transducers have highlighted the need for cryogenic optical measurements. In this study, we present a packaged fiber-optic coupler with a coupling efficiency of over 50% for telecom wavelength light down to the mK temperature range. Besides the high coupling efficiency, our method enables sensitive photonic device measurements that are immune to mechanical vibrations present in cryogenic setups.

Optics↗

Characterizing thermal-induced temporal drift in deployed quantum fiber networks

We study temperature-induced fiber-delay drifts affecting entanglement fidelity in deployed quantum systems. Using field data and simulations, we model timing uncertainties and evaluate their impact on coincidence detection, revealing critical challenges for robust quantum networks.

Alshowkan, Muneer [ORNL] (ORCID:0000000264293450)↗

Ancilla-assisted process tomography of a deployed fiber link

We perform ancilla-assisted process tomography over a deployed 1.6 km fiber-optic link using Bayesian inference, confirming a stable, high-fidelity polarization channel. Overall, our approach should offer value for in situ analyses of entanglement networks.

Rahman, Arefur [Arizona State University]↗

Plasmonics-enhanced photoconductive terahertz detector pumped by Ytterbium-doped fiber laser

We present a photoconductive terahertz detector operating at the 1 µm wavelength range at which high-power and compact Ytterbium-doped femtosecond fiber lasers are available. The detector utilizes an array of plasmonic nanoantennas to provide sub-picosecond transit time for the majority of photo-generated carriers to enable high-sensitivity terahertz detection without using a short-carrier-lifetime substrate. By using a high-mobility semiconductor substrate and preventing photocarrier recombination, the presented detector offers significantly higher sensitivity levels compared with previously demonstrated broadband photoconductive terahertz detectors operating at the 1 µm wavelength range. We demonstrate pulsed terahertz detection over a 4 THz bandwidth with a record-high signal-to-noise ratio of 95 dB at an average terahertz radiation power of 6.8 µW, when using an optical pump power of 30 mW.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Distributed fiber sensor and machine learning data analytics for pipeline protection against extrinsic intrusions and intrinsic corrosions

This paper presents an integrated technical framework to protect pipelines against both malicious intrusions and piping degradation using a distributed fiber sensing technology and artificial intelligence. A distributed acoustic sensing (DAS) system based on phase-sensitive optical time-domain reflectometry (φ-OTDR) was used to detect acoustic wave propagation and scattering along pipeline structures consisting of straight piping and sharp bend elbow. Signal to noise ratio of the DAS system was enhanced by femtosecond induced artificial Rayleigh scattering centers. Data harnessed by the DAS system were analyzed by neural network-based machine learning algorithms. The system identified with over 85% accuracy in various external impact events, and over 94% accuracy for defect identification through supervised learning and 71% accuracy through unsupervised learning.

Peng, Zhaoqiang↗