Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “fault current”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 865 records · Page 48

Detection of CMOS bridging faults using minimal stuck-at fault test sets

The performance of minimal stuck-at fault test sets at detecting bridging faults are evaluated. New functional models of circuit primitives are presented which allow accurate representation of bridging faults under switch-level simulation. The effectiveness of the patterns is evaluated using both voltage and current testing.

Ijaz, Nabeel↗

An Overview of ANN Application in the Power Industry

The paper presents a survey on the development and experience with artificial neural net (ANN) applications for electric power systems, with emphasis on operational systems. The organization and constraints of electric utilities are reviewed, motivations for investigating ANN are identified, and a current assessment is given from the experience of 2400 projects using ANN for load forecasting, alarm processing, fault detection, component fault diagnosis, static and dynamic security analysis, system planning, and operation planning.

artificial neural networks ANN electric power syst↗

Development and Flight Testing of a Neural Network Based Flight Control System on the NF-15B Aircraft

The Intelligent Flight Control System (IFCS) project at the NASA Dryden Flight Research Center, Edwards AFB, CA, has been investigating the use of neural network based adaptive control on a unique NF-15B test aircraft. The IFCS neural network is a software processor that stores measured aircraft response information to dynamically alter flight control gains. In 2006, the neural network was engaged and allowed to learn in real time to dynamically alter the aircraft handling qualities characteristics in the presence of actual aerodynamic failure conditions injected into the aircraft through the flight control system. The use of neural network and similar adaptive technologies in the design of highly fault and damage tolerant flight control systems shows promise in making future aircraft far more survivable than current technology allows. This paper will present the results of the IFCS flight test program conducted at the NASA Dryden Flight Research Center in 2006, with emphasis on challenges encountered and lessons learned.

Bomben, Craig R.↗

Methods for locating ground faults and insulation degradation condition in energy conversion systems

Methods for determining a ground fault or insulation degradation condition within energy conversion systems are described. A method for determining a ground fault within an energy conversion system may include, in part, a comparison of baseline waveform of differential current to a waveform of differential current during operation for a plurality of DC current carrying conductors in an energy conversion system. A method for determining insulation degradation within an energy conversion system may include, in part, a comparison of baseline frequency spectra of differential current to a frequency spectra of differential current transient at start-up for a plurality of DC current carrying conductors in an energy conversion system. In one embodiment, the energy conversion system may be a photovoltaic system.

30 DIRECT ENERGY CONVERSION↗

Analysis of Gaps in Geothermal Exploration Data in the Western United States

The USGS Resource Assessment (Williams et al. 2008) outlined a mean 30 GW, of Undiscovered Hydrothermal Resource in the western U.S. One goal of the Geothermal Technology Office (GTO) is to accelerate the development of this undiscovered resource. To help guide its future data collection efforts, GTO funded a data gap analysis in FY2012 to identify high potential hydrothermal areas where critical data are needed. For the gap analysis, information was collected about existing data and data coverage maps were created with this information. Next, these maps were compared with the USGS resource potential maps to identify priority sites for exploration data collection. Though there are many types of data that can be used for hydrothermal exploration, five types of exploration data were targeted for this analysis. These data types were elected for their regional reconnaissance potential, and include many of the primary exploration echniques currently used by the geothermal industry. The data types include: 1) well data; 2) geologic maps; 3) fault maps; 4) geochemistry data; and 5) geophysical data. To determine data coverage, metadata for exploration data (including data type, data status, and coverage information) were collected and catalogued. Many industry, university, laboratory, and agency personnel were contacted in order to collect metadata for this effort. Data and metadata provided by the contributors to the National Geothermal Data System (NGDS) were also incorporated in the gap analysis. An online tool was developed to allow all geothermal data providers to directly add metadata themselves and view the results of the analys is via maps of data coverage in Geothermal Prospector (http://maps.nrel.gov/gt_prospector). A grid of the contiguous U.S. was created with 88,000 10-km by 10-km grid cells, and each cell was populated with the status of data availability corresponding to the five data types. Using these five data coverage maps and the USGS Resource Potential Map, sites were identified for future data collection efforts. These sites signify both that the USGS has indicated high favorability of occurrence of geothermal resources and that data gaps exist.

15 GEOTHERMAL ENERGY↗

Efficient Probabilistic Diagnostics for Electrical Power Systems

We consider in this work the probabilistic approach to model-based diagnosis when applied to electrical power systems (EPSs). Our probabilistic approach is formally well-founded, as it based on Bayesian networks and arithmetic circuits. We investigate the diagnostic task known as fault isolation, and pay special attention to meeting two of the main challenges . model development and real-time reasoning . often associated with real-world application of model-based diagnosis technologies. To address the challenge of model development, we develop a systematic approach to representing electrical power systems as Bayesian networks, supported by an easy-to-use speci.cation language. To address the real-time reasoning challenge, we compile Bayesian networks into arithmetic circuits. Arithmetic circuit evaluation supports real-time diagnosis by being predictable and fast. In essence, we introduce a high-level EPS speci.cation language from which Bayesian networks that can diagnose multiple simultaneous failures are auto-generated, and we illustrate the feasibility of using arithmetic circuits, compiled from Bayesian networks, for real-time diagnosis on real-world EPSs of interest to NASA. The experimental system is a real-world EPS, namely the Advanced Diagnostic and Prognostic Testbed (ADAPT) located at the NASA Ames Research Center. In experiments with the ADAPT Bayesian network, which currently contains 503 discrete nodes and 579 edges, we .nd high diagnostic accuracy in scenarios where one to three faults, both in components and sensors, were inserted. The time taken to compute the most probable explanation using arithmetic circuits has a small mean of 0.2625 milliseconds and standard deviation of 0.2028 milliseconds. In experiments with data from ADAPT we also show that arithmetic circuit evaluation substantially outperforms joint tree propagation and variable elimination, two alternative algorithms for diagnosis using Bayesian network inference.

Mengshoel, Ole J.↗

A fresh view of the fly-by-light/power-by-wire program

NASA has been funding a focused program to promote the development of optical signaling and electrical actuation for civil transports. This program is reviewed in the context of other government and private sector initiatives. It is concluded that significant resources have and continue to be expended to develop these technologies. A second goal of the program is to develop certification methods for aircraft that implement these new technologies. It is concluded that there is a significant need for this effort and that NASA in cooperation with the FAA are well suited to do satisfy the need. Electrical actuation is not new but has recently been made feasible for a broader array of high power applications than previously because of developments in power switching technologies, motors, and computers. This development has been well explored by the Air Force and the private sector and requires little more government attention. Light signal and sensor technology has been developing under public and private funding and has reached a level of maturity such that some companies are using optical signal carriers for flight control on private jets. Several issues remain unresolved but centrally focused government effort is not an effective way to pursue the variety of issues that persist. Certification of aircraft for flight is a government activity. The poor preparedness of the FAA to certify fault tolerant digital flight control systems against electromagnetic effects coupled with the increasing number of electromagnetic emitters constitutes an impediment for development of this technology. The complete lack of preparation to certify optical components is currently causing concern for a general aviation supplier who is having difficulty certify their system. NASA with the FAA should work to develop clear, reasonable, and cost effective ways of certifying the reliability of fault tolerant digital and optical flight control components and systems.

Wander, John↗

Digitally Controlled High Availability Power Supply

This paper will report on the test results of a prototype 1320 watt power module for a high availability power supply. The module will allow parallel operation for N+1 redundancy with hot swap capability. The two quadrant output of each module allows pairs of modules to provide a 4 quadrant (bipolar) operation. Each module employs a novel 4 FET buck regulator arranged in a bridge configuration. Each side of the bridge alternately conducts through a small saturable ferrite that limits the reverse current in the FET body diode during turn off. This allows hard switching of the FETs with low switching losses. The module is designed with over-rated components to provide high reliability and better then 97% efficiency at full load. The modules use a Microchip DSP for control, monitoring, and fault detection. The switching FETS are driven by PWM modules in the DSP at 60 KHz. A Dual CAN bus interface provides for low cost redundant control paths. The DSP will also provide current sharing between modules, synchronized switching, and soft start up for hot swapping. The input and output of each module have low resistance FETs to allow hot swapping and isolation of faulted units.

42 ENGINEERING↗

EReinit: Scalable and efficient fault-tolerance for bulk-synchronous MPI applications

Scientists from many different fields have been developing Bulk-Synchronous MPI applications to simulate and study a wide variety of scientific phenomena. Since failure rates are expected to increase in larger-scale future HPC systems, providing efficient fault-tolerance mechanisms for this class of applications is paramount. The global-restart model has been proposed to decrease the time of failure recovery in Bulk-Synchronous applications by allowing a fast reinitialization of MPI. However, the current implementations of this model have several drawbacks: they lack efficiency; their scalability have not been shown; and they require the use of the MPI profiling interface, which precludes the use of tools. Here, we present EReinit, an implementation of the global-restart model that addresses these problems. Our key idea and optimization is the co-design of basic fault-tolerance mechanisms such as failure detection, notification, and recovery between MPI and the resource manager in contrast to current approaches on which these mechanisms are implemented in MPI only. We demonstrate EReinit in three HPC programs and show that it is up to four times more efficient than existing solutions at 4,096 processes.

97 MATHEMATICS AND COMPUTING↗

Remote sensing of atmospheric pressure and sea state from satellites using short-pulse multicolor laser altimeters

Short pulse multicolor laser ranging systems are currently being developed for satellite ranging applications. These systems use Q-switched pulsed lasers and streak tube cameras to provide timing accuracies approaching a few picoseconds. Satellite laser ranging systems was used to evaluate many important geophysical phenomena such as fault motion, polar motion and solid earth tides, by measuring the orbital perturbations of retroreflector equipped satellites. Some existing operational systems provide range resolution approaching a few millimeters. There is currently considerable interest in adapting these highly accurate systems for use as airborne and satellite based altimeters. Potential applications include the measurement of sea state, ground topography and atmospheric pressure. This paper reviews recent progress in the development of multicolor laser altimeters for use in monitoring sea state and atmospheric pressure.

Gardner, C. S.↗

A Fast-Response High-Accuracy Overvoltage Protection Circuit for Soft-Switching Current-Source Converters

Although voltage-source converters (VSCs) have been a focus of research for decades and are widely applied in numerous applications, they face great challenges in short-circuit failures, high dv/dt and electromagnetic interference (EMI), especially using wide bandgap devices. Instead, current-source converters (CSCs) are attracting increasing attention in recent years owing to their friendliness to short-circuit faults, improved EMI, etc. For CSCs, overvoltage is the most catastrophic failure since the semiconductor devices can hardly withstand an overvoltage for a short pulse. In this paper, a fast-response high-accuracy overvoltage protection (OVP) circuit is proposed to protect CSCs from overvoltage damage. It also features a small form factor, good noise-immunity, friendly retrofit capability, and no need for active switches. In this paper, the operating principle and design guideline of the proposed OVP circuit is introduced. Its effectiveness is validated in soft-switching solid-state transformer (S4T) at 500 V. In experiments, the voltage detection error of less than 5% and a propagation delay of fewer than 400 ns have been achieved.

30 DIRECT ENERGY CONVERSION↗

Control, Fault Management, and Grid Support Functionality of an MV AC-DC Solid State Transformer based EV Extreme Fast Charging Station

Electric vehicles (EVs) have become increasingly popular in recent times while revolutionizing the consumer and commercial transportation market. The development of charging infrastructure has become one of the priorities for increasing the adoption of EVs. Extreme fast charging (XFC) technology can reduce the so-called ’range anxiety’ of consumers as they significantly reduce the charging time. With the advent of wide band-gap (WBG) power devices and improvement in power electronic converters, medium voltage (MV) solid state transformer (SST) based XFC system has the potential to replace the traditional XFC stations because of the lower footprint, ease of installation, enhanced control feature, and better system efficiency. The control system design is one of the critical aspects of the SST development process. Careful consideration and detailed analysis are required to find out suitable control method for the SST based on its topology among different centralized and decentralized control architectures. Also, the control parameters selection and potential improvement to the transient response of the controller ought to be investigated. Another major concern of the SST is different types of internal fault which reduces the overall reliability of the XFC system. As a result, designing a robust protection system is essential. Among different fault modes, open circuit switch faults have received significant attention as an active research area because of their likelihood and severe effects on converters. Therefore, the power stages used in the XFC system require functional and accurate open circuit switch fault management methods. An equally significant aspect of this SST based XFC is its compatibility in a microgrid where there is no synchronous generator present. When the grid is not available, the XFC SSTs can provide grid forming capability and continue supplying the critical loads in islanded mode. The transition between grid connected and islanded mode, especially the grid resynchronization process has to be carefully performed for the safety of the microgrid components. The challenges posed by the aforementioned issues have inspired the work done in this dissertation. Here, a 13.2 kV, 1 MVA, AC/DC SST for the XFC system is examined and a comparative analysis is conducted to select the control architecture based on feasibility of implementation and performance. A detailed control parameter design process is demonstrated considering the sensor dynamics and delay. The selected decentralized control method is augmented by introducing a novel sensor-less load current feedforward method to provide better voltage regulation at the DC bus during a change of load. Next, in the fault management section, a hierarchical failure mode effect analysis (FMEA) is proposed to enable a systematic design of the internal fault protection of the XFC SST as there are limited examples in the literature regarding the analysis of the safety and design of the protection of a power electronic converter system. Novel open circuit switch fault management methods for the converters in the system are presented. Finally, XFC SST based MV microgrid operations in grid connected mode and islanded mode are explored. A secondary control method for grid resynchronization is presented and a design process of control parameters is shown to ensure the stability of the secondary voltage and frequency regulation.

30 DIRECT ENERGY CONVERSION↗

Remote sensing of atmospheric pressure and sea state using laser altimeters

Short-pulse multicolor laser ranging systems are currently being developed for satellite ranging applications. These systems use Q-switched pulsed lasers and streak-tube cameras to provide timing accuracies approaching a few picoseconds. Satellite laser ranging systems have been used to evaluate many important geophysical phenomena such as fault motion, polar motion and solid earth tides, by measuring the orbital perturbations of retroreflector equipped satellites. Some existing operational systems provide range resolution approaching a few millimeters. There is currently considerable interest in adapting these highly accurate systems for use as airborne and satellite based altimeters. Potential applications include the measurement of sea state, ground topography and atmospheric pressure. This paper reviews recent progress in the development of multicolor laser altimeters for use in monitoring sea state and atmospheric pressure.

Gardner, C. S.↗

Unattended network operations technology assessment study. Technical support for defining advanced satellite systems concepts

The results are summarized of an unattended network operations technology assessment study for the Space Exploration Initiative (SEI). The scope of the work included: (1) identified possible enhancements due to the proposed Mars communications network; (2) identified network operations on Mars; (3) performed a technology assessment of possible supporting technologies based on current and future approaches to network operations; and (4) developed a plan for the testing and development of these technologies. The most important results obtained are as follows: (1) addition of a third Mars Relay Satellite (MRS) and MRS cross link capabilities will enhance the network's fault tolerance capabilities through improved connectivity; (2) network functions can be divided into the six basic ISO network functional groups; (3) distributed artificial intelligence technologies will augment more traditional network management technologies to form the technological infrastructure of a virtually unattended network; and (4) a great effort is required to bring the current network technology levels for manned space communications up to the level needed for an automated fault tolerance Mars communications network.

Price, Kent M.↗

Explicit analytical modeling of the low frequency a-Si:H/c-Si heterojunction capacitance: Analysis and application to silicon heterojunction solar cells

We develop a fully analytical model in order to describe the temperature dependence of the low frequency capacitance of heterojunctions between hydrogenated amorphous silicon (a-Si:H) and crystalline silicon (c-Si). We demonstrate that the slope of the capacitance-temperature (C-T) curve is strongly enhanced if the c-Si surface is under strong inversion conditions compared to the usually assumed depletion layer capacitance. We have extended our analytical model to integrate a very thin undoped (i) a-Si:H layer at the interface and the finite thickness of the doped a-Si:H layer that are used in high efficiency solar cells for the passivation of interface defects and to limit short circuit current losses. Finally, using our calculations, we analyze experimental data on high efficiency silicon heterojunction solar cells. The transition from the strong inversion limited behavior to the depletion layer behavior is discussed in terms of band offsets, density of states in a-Si:H, and work function of the indium tin oxide (ITO) front electrode. In particular, it is evidenced that strong inversion conditions prevail at the c-Si surface at high temperatures down to 250 K, which can only be reproduced if the ITO work function is larger than 4.7 eV.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Tuning back contact property via artificial interface dipoles in Si/organic hybrid solar cells

Back contact property plays a key role in the charge collection efficiency of c-Si/poly(3,4-ethylthiophene):poly(styrenesulfonate) hybrid solar cells (Si-HSCs), as an alternative for the high-efficiency and low-cost photovoltaic devices. In this letter, we utilize the water soluble poly (ethylene oxide) (PEO) to modify the Al/Si interface to be an Ohmic contact via interface dipole tuning, decreasing the work function of the Al film. This Ohmic contact improves the electron collection efficiency of the rear electrode, increasing the short circuit current density (J{sub sc}). Furthermore, the interface dipoles make the band bending downward to increase the total barrier height of built-in electric field of the solar cell, enhancing the open circuit voltage (V{sub oc}). The PEO solar cell exhibits an excellent performance, 12.29% power conversion efficiency, a 25.28% increase from the reference solar cell without a PEO interlayer. The simple and water soluble method as a promising alternative is used to develop the interfacial contact quality of the rear electrode for the high photovoltaic performance of Si-HSCs.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Current–voltage characteristics of high-voltage 4H-SiC p{sup +}–n{sub 0}–n{sup +} diodes in the avalanche breakdown mode

p{sup +}–n{sub 0}–n{sup +} 4H-SiC diodes with homogeneous avalanche breakdown at 1860 V are fabricated. The pulse current–voltage characteristics are measured in the avalanche-breakdown mode up to a current density of 4000 A/cm{sup 2}. It is shown that the avalanche-breakdown voltage increases with increasing temperature. The following diode parameters are determined: the avalanche resistance (8.6 × 10{sup –2} Ω cm{sup 2}), the electron drift velocity in the n{sub 0} base at electric fields higher than 10{sup 6} V/cm (7.8 × 10{sup 6} cm/s), and the relative temperature coefficient of the breakdown voltage (2.1 × 10{sup –4} K{sup –1}).

36 MATERIALS SCIENCE↗