Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “false positive”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 865 records · Page 48

Planetary Candidates from K2 Campaign 16

Given that Campaign 16 of the K2 mission is one of just two K2 campaigns observed so far in "forward-facing" mode, which enables immediate follow-up observations from the ground, we present a catalog of interesting targets identified through photometry alone. Our catalog includes 30 high-quality planet candidates (showing no signs of being non-planetary in nature), 48 more ambiguous events that may be either planets or false positives, 164 eclipsing binaries, and 231 other regularly periodic variable sources. We have released light curves for all targets in C16 and have also released system parameters and transit vetting plots for all interesting candidates identified in this paper. Of particular interest is a candidate planet orbiting the bright F dwarf HD 73344 (V = 6.9, K = 5.6) with an orbital period of 15 days. If confirmed, this object would correspond to a 2.56 +/- 0.18 R⊕ planet and would likely be a favorable target for radial velocity characterization. This paper is intended as a rapid release of planet candidates, eclipsing binaries, and other interesting periodic variables to maximize the scientific yield of this campaign, and as a test run for the upcoming TESS mission, whose frequent data releases call for similarly rapid candidate identification and efficient follow up.

bright F dwarf↗

LADEE Preparations for Contingency Operations for the Lunar Orbit Insertion Maneuver

The Lunar Atmosphere and Dust Environment Explorer (LADEE) spacecraft was launched on September 6, 2013, and completed its mission on April 17, 2014 with a directed impact to the Lunar Surface. Its primary goals were to examine the lunar atmosphere, measure lunar dust, and to demonstrate high rate laser communications. The LADEE mission was a resounding success, achieving all mission objectives, much of which can be attributed to careful planning and preparation. This paper discusses the specific preparations for fault conditions that could occur during a highly-critical phase of the mission. To get to the Moon, the spacecraft traversed multiple phasing loops around the Earth, and then executed a breaking maneuver to achieve lunar orbit. This Lunar Orbit Insertion (LOI) maneuver was perhaps the most time-critical phase of the entire mission. The LOI maneuver had to occur within a twenty minute window in order to achieve lunar orbit with an acceptable amount of propellant remaining. Missing this window would have likely resulted in a loss of the entire mission. An additional challenge of the maneuver was that spacecraft was out of view for approximately one hour prior to the main thruster burn, with the burn needing to occur within five minutes after coming into view. These conditions resulted in unique challenges for ground operations and the fault management system. Early in the planning stages of the mission, the criticality and challenges of this maneuver were evident to the system designers. The major concern was that any triggering of the on-board fault management system, whether it is in response to a true fault or a false positive, would result in an unacceptable delay to the burn. Therefore the flight software was designed with a flexible fault management system, such that any or all of the fault management responses could be disabled for the lead up and execution of the maneuver. Later, a triage was conducted to develop a list of fault responses, mapped to various parts of the timeline of the maneuver. Some of these contingency responses were solely ground-based if the time to detect, diagnose, and respond were adequate. Other responses were automated on-board if the response time from the ground would have been inadequate. For instance, in order to recover from a system reboot, on-board automation would have automatically reconfigured the spacecraft for the burn and reoriented the spacecraft to the burn attitude.These contingency responses were practiced, over and over, during numerous rehearsals. Although the LOI maneuver was executed without having to use any of these contingencies, the LADEE team was adequately prepared for this highly critical phase of the mission.

Cannon, Howard↗

Carbon Nanostructures in Biological Sensors for Space and Terrestrial Applications

Biosensing devices comprised of carbon nanotubes and nanofibers have been developed for astronaut crew point-of-care. Their inherent nanometer scale, high conductivity, wide potential window, good biocompatibility and well-defined surface chemistry make them ideal candidates as biosensor electrodes. Here, we report two studies using carbon nanotube and carbon nanofiber electrodes for biomedical applications. First, a 3x3 electrode device, with each electrode containing 40,000 carbon nanofiber nanoelectrodes was fabricated on silicon using traditional microfabrication processing. The device was demonstrated as a multiplexed immunosensor for simultaneous, label-free detection of cardiac troponin-I, C-reactive protein and myoglobin. Antibodies specific to cardiac troponin-I, C-reactive protein and myoglobin were covalently bound to the CNF surface and were characterized using electrochemical impedance spectroscopy and differential pulse voltammetry. Each step of the modification process resulted in changes in resistance to charge transfer due to the changes at the electrode surface upon antibody immobilization and binding to the specific cardiac protein. The real-time label free detection of the three cardiac markers from pure components and mixtures was demonstrated with high sensitivity, down to 0.2 ng/mL, and good selectivity. Detection in human blood serum did not present false positives from non-specific protein adsorption. More recently, this detection scheme has been applied to inkjet printed carbon nanotube electrodes on Kapton and paper. Printed devices have several unique advantages including simple and inexpensive fabrication. The results demonstrate that these sensors can serve a miniaturized, low cost device for detection of proteins in complex mixtures making this platform a good candidate for early stage diagnosis of myocardial infarction. Future inkjet printed devices can be fabricated have the added advantage in their suitability to be manufactured in an in-space, microgravity environment.

carbon nanotubes↗

Reducing V&V Cost of Flight Critical Systems: Myth or Reality?

This paper presents an overview of NASA research program on the V&V of flight critical systems. Five years ago, NASA started an effort to reduce the cost and possibly increase the effectiveness of V&V for flight critical systems. It is the right time to take a look back and realize what progress has been made. This paper describes our overall approach and the tools introduced to address different phases of the software lifecycle. For example, we have improved testing by developing a statistical learning approach tor defining test cases. The tool automatically identifies possible unsafe conditions by analyzing outliers in output data; using an iterative learning process, it can then generate more test cases that represent potentially unsafe regions of operation. At the code level, we have developed and made available as open source a static analyzer for C and C++ programs called IKOS. We have shown that IKOS is very precise in the analysis of embedded C programs (very few false positives) and a bit less for regular C and C++ code. At the design level, in collaboration with our NRA partners, we have developed a suite of analysis tools for Simulink models. The analysis is done in a compositional framework for scalability.

Brat, Guillaume P.↗

Carbon Nanomaterials for Biosensing Applications

Biosensing devices comprised of carbon nanotubes and nanofibers have been developed for astronaut crew point-of-care. Their inherent nanometer scale, high conductivity, wide potential window, good biocompatibility and well-defined surface chemistry make them ideal candidates as biosensor electrodes. Here, we report two studies using carbon nanotube and carbon nanofiber electrodes for biomedical applications. First, a 3x3 electrode device, with each electrode containing 40,000 carbon nanofiber nanoelectrodes was fabricated on silicon using traditional microfabrication processing. The device was demonstrated as a multiplexed immunosensor for simultaneous, label-free detection of cardiac troponin-I, C-reactive protein and myoglobin. Antibodies specific to cardiac troponin-I, C-reactive protein and myoglobin were covalently bound to the CNF surface and were characterized using electrochemical impedance spectroscopy and differential pulse voltammetry. Each step of the modification process resulted in changes in resistance to charge transfer due to the changes at the electrode surface upon antibody immobilization and binding to the specific cardiac protein. The real-time label free detection of the three cardiac markers from pure components and mixtures was demonstrated with high sensitivity, down to 0.2 ng/mL, and good selectivity. Detection in human blood serum did not present false positives from non-specific protein adsorption. More recently, this detection scheme has been applied to inkjet printed carbon nanotube electrodes on Kapton and paper. Printed devices have several unique advantages including simple and inexpensive fabrication. The results demonstrate that these sensors can serve a miniaturized, low cost device for detection of proteins in complex mixtures making this platform a good candidate for early stage diagnosis of myocardial infarction. Future inkjet printed devices can be fabricated have the added advantage in their suitability to be manufactured in an in-space, microgravity environment.

carbon nanotubes↗

UV Shielding of Bacillus pumilus SAFR-032 Endospores by Martian Regolith Simulants

As exploration of the solar system advances with life detection missions on the horizon, the concern for planetary protection has grown considerably. When attempting to detect extraterrestrial life, the likelihood of false positives from terrestrial contamination must be minimized. The Exposing Microorganisms in the Stratosphere (E-MIST) balloon project aims to evaluate whether resilient terrestrial bacteria can survive stressors in a Mars-like environment. This is accomplished by sending Bacillus pumilus SAFR-032, an endospore-forming bacterial isolate from a spacecraft assembly facility, to the Earth's middle stratosphere (30-38 kilometers), where low temperature and pressure and high radiation and dryness conditions are similar to the surface of Mars. Previous ground and flight tests showed that the vast majority of SAFR-032 spores (99.99 percent) were inactivated by direct sunlight due to ultraviolet (UV) radiation. This observation led us to explore the role of dust shielding in changing microbial survivorship outcomes. To determine the dust particle distributions and density for potentially shielding microbes from UV radiation, samples of a Martian dust simulant were mixed with SAFR-032 spores. The dry heat sterilized simulant used was JSC MARS-1, weathered volcanic ash from Hawaii that displays many chemical and physical properties similar to the Martian soil as characterized by the Viking Lander 1, including reflectance spectrum, chemical composition, mineralogy, grain size, specific gravity, and magnetic properties. First, scanning electron microscopy was undertaken to visualize the aggregation of the spores with dust particles (i.e., shading effects), and samples of varying dust concentrations were subsequently irradiated with UVC light to test survivorship outcomes. After a relationship between dust concentration and spore survivorship was determined, a solar simulator capable of irradiating samples with a fuller UV spectrum (less than 280-400 nanometers) was used to perform a more robust middle stratosphere simulation. Taken together, we will use results from the ground-based irradiation studies to feed into experimental designs for the next E-MIST ultra-long duration polar balloon flight launched by NASA.

Stratosphere↗

Statistical Hypothesis Testing in Wavelet Analysis: Theoretical Developments and Applications to Indian Rainfall

Statistical hypothesis tests in wavelet analysis are methods that assess the degree to which a wavelet quantity(e.g., power and coherence) exceeds background noise. Commonly, a point-wise approach is adopted in which a wavelet quantity at every point in a wavelet spectrum is individually compared to the critical level of the point-wise test. However, because adjacent wavelet coefficients are correlated and wavelet spectra often contain many wavelet quantities, the point-wise test can produce many false positive results that occur in clusters or patches. To circumvent the point-wise test drawbacks, it is necessary to implement the recently developed area-wise, geometric, cumulative area-wise, and topological significance tests, which are reviewed and developed in this paper. To improve the computational efficiency of the cumulative area-wise test, a simplified version of the testing procedure is created based on the idea that its output is the mean of individual estimates of statistical significance calculated from the geometric test applied at a set of point-wise significance levels. Ideal examples are used to show that the geometric and cumulative area-wise tests are unable to differentiate wavelet spectral features arising from singularity-like structures from those associated with periodicities. A cumulative arc-wise test is therefore developed to strictly test for periodicities by using normalized arc length, which is defined as the number of points composing a cross section of a patch divided by the wavelet scale in question. A previously proposed topological significance test is formalized using persistent homology profiles (PHPs) measuring the number of patches and holes corresponding to the set of all point-wise significance values. Ideal examples show that the PHPs can be used to distinguish time series containing signal components from those that are purely noise. To demonstrate the practical uses of the existing and newly developed statistical methodologies, a first comprehensive wavelet analysis of Indian rainfall is also provided. An R software package has been written by the author to implement the various testing procedures.

Wind speed↗

Searching for Life on Mars: The Contamination Paradox

As we search for life on Mars, we will be simultaneously contaminating Mars with life from Earth. The contamination from Earth could be mistaken for Martian life. How can this paradox be avoided? With the results of our research, the scientific community will be able to determine locations of future habitats that minimize the aerial extent subject to bio-contaminants, protect sites of astrobiological interest, and constrain landing site selection of life detection missions to reduce risk of false positives. We consider a putative human habitat on Mars. Biological contaminants will flow out of the habitat into the Martian atmosphere, and the atmosphere will move these contaminants around. How many biological particles per year will be released from the habitat into the Martian ambient environment? How far will the contamination travel? In what directions will it travel? How long will the contamination be in the atmosphere? We study these questions quantitatively by simulating the Martian atmosphere using the NASA Ames Mars Global Climate Model. Various combinations of human habitat locations and contaminant sizes are considered. The results from these simulations enable the creation of novel contamination heat maps showing the aerial distribution of contaminants from putative human habitats on Mars.

Contamination↗

Lipid Decontamination Procedures for Life Detection Missions

Molecular biosignatures are key targets for current, proposed, and future life detection missions. With the high accuracy and low limit of detection (LOD) that new and future instruments will require, decontamination of life detection hardware is necessary to prevent false positives. Lipids are a molecular biosignature of interest, as they are ubiquitous to all life as we know it, can survive unaltered in the geologic record for longer than any other biomolecule (i.e. billions of years), and form through both biotic and abiotic processes. Lipids display origin-diagnostic molecular patterns that can reveal biotic or abiotic synthesis, so finding them and ascertaining their molecular features is important for potentially detecting evidence of life elsewhere. Traditional methods of decontamination, or contamination control (CC), primarily clean hardware through fabrication in sterile (cleanroom) environments, killing microbes, and removing/flushing contaminants off instrument and spacecraft components. However, research suggests that some standard cleaning methods are either unlikely to remove lipid contaminants or are incompatible with life detection instrument materials. To solve this problem, I propose to find, test, and verify a decontamination method that thoroughly cleans instruments by destroying lipid molecules, but is simultaneously compatible with major materials used in these instruments. I will study the effects of traditional CC methods (including Dry Heat Microbial Reduction and Vapor phase Hydrogen Peroxide) and experimental CC methods (Electron Beam Irradiation) on lipid molecules for application to life detection instrumentation. I will then develop a CC plan for a novel lipid detector (ExCALiBR, Extractor for Chemical Analysis of Lipid Biomarkers in Regolith) searching for lipids in either soil or icy world scenarios. This plan will uphold planetary protection regulation requirements and validate experimental analyses of in-situ life detection tests.

Decontamination↗

Where Is the Upper Altitude Boundary of Earth's Biosphere? An Upcoming Stratosphere Exploration Mission

Earths atmosphere provides a relatively thin barrier to the severe conditions of space. Terrestrial microorganisms from our planets surface gets swept up into the atmosphere at rates which are influenced by meteorology, season, and variety of other regionally-dependent conditions. Residence time of microbes in the atmosphere, dispersal patterns, and metabolic activity in clouds are topics of special interest in tropospheric aerobiology. But what about even higher altitudes? A century of ocean exploration has allowed the scientific community to characterize marine life at every depth. Such knowledge was enabled by routine access, specifically, submersible vehicles with sample return systems. The outer reaches of Earth's atmosphere probably contain trace signatures of microbial life swept up from the surface, but high-altitude exploration (from 18-50 km above sea level) has been severely constrained by a shortage of reliable affordable sample acquisition systems. Thus, attempts to establish the upper altitude limits of Earths biosphere boundary remain unresolved. Previous conclusions based on observations of microbial growth and DNA signatures from samples collected in the upper atmosphere have resulted in extraordinary claims for the tenacity of life in the stratosphere. This altitude range can be regarded as a natural laboratory for examining the edge of habitability, a topic of central important to the field of astrobiology; in fact, stratosphere conditions (high UV light and low extremes of temperature, pressure, and relative humidity) closely resemble stressors associated with the surface of Mars. Moreover, low biomass detection instruments developed exploring Earths upper atmosphere can contribute to future strategies for life detection with spacecraft exploring other worlds. While pioneering, many past stratospheric microbiology studies have been qualitative in nature and lacking rigorous contamination control measurements to verify system sterility. We have designed, constructed, and recently flown a novel system for collecting upper atmosphere bioaerosols using the NASA C20A aircraft. We will report preliminary mission results from the lower stratosphere (characterizing abundance, diversity and survivability or airborne microorganisms), describe our methods for reducing false positives, and outline the open scientific engineering challenges in an ongoing effort to better establish Earths high-altitude biosphere boundary.

Smith, David J.↗

Enhancing GPM Passive and Combined Microwave Algorithms with Dynamic Surface Information for Drizzle Retrieval and Improved Precipitation Detection Over Land

Following the 2014 launch of the Global Precipitation Measurement Mission (GPM), an unprecedented combination of coincident active and passive microwave observations are available for state of the art precipitation retrieval. The GPM Combined Algorithm forms the backbone of this effort, optimizing geophysical variables for agreement with the full suite of multi-spectral information content. These combined retrievals are then utilized, along with a radiative transfer model, as a database applied for retrievals across a constellation of passive microwave radiometers of varying frequencies. By keeping such retrievals related through the transfer standard of the combined algorithm, level 3 products such as the Integrated Multi-satellitE Retrievals for GPM (IMERG) are able to provide consistent global products for users at the higher temporal resolution required for hydrological applications. In initial versions of the combined product, precipitation retrievals are carried out only in the presence of a signal from the active radar. As a result, light precipitation and drizzle below the threshold of DPR sensitivity are not included in any of the products down the chain from the constellation to IMERG. In this work, the effects of enhancing the retrievals with a surface emissivity and non-raining water vapor retrieval using the passive observations are explored. Over both ocean and land, the surface retrieval is used to identify areas with high probability of light precipitation and drizzle which is then quantified using techniques derived from the higher sensitivity CloudSat mission. Results indicate successful inclusion of drizzle in the retrievals that can then be included in the constellation databases, as well as improvement in passive microwave false positive precipitation signals over land in cases where surface scattering was misinterpreted as precipitation signal. The inclusion of the dynamic surface information also creates a more robust, radiometrically consistent retrieval scheme for process studies and hydrologic applications.

Ringerud, Sarah↗

String Midpoint Monitoring for Li-Ion Batteries

The paper introduces the midpoint monitoring method for detecting cell voltage imbalance in a series string of 8 electrochemical cells. Monte Carlo analysis is performed for normal cell End of Discharge open and closed circuit voltage behavior to assess the extent to which derived guard band voltage limits will detect over discharged cells, provide false positive indication, or fail to detect over discharged cells. Forward work is proposed to refine the battery monitoring method for operational use in 28V lithium ion batteries.

Russell, S.↗

Planetary Protection Technologies for Planetary Science Instruments, Spacecraft, and Missions: Report of the NASA Planetary Protection Technology Definition Team (PPTDT)

Planetary bodies like Mars, Europa, and Enceladus pose the question, "How to study them without contaminating them and destroying future prospects to detect life, if it is there?" The natural trade-off, of course, is that the cleaner your spacecraft, the more you can explore such a body without risk of contaminating it. As chartered by NASA Headquarters, the Planetary Protection Technology Definition Team (PPTDT) was asked to provide a report covering six different areas related to the engineering and technology challenges of implementing planetary protection requirements on solar system exploration missions, including: Assessment of technical and engineering challenges to applying available microbial-reduction methods, including recontamination prevention, to spacecraft hardware and instruments, to meet current NASA requirements on preventing the forward contamination of potentially habitable worlds by future spacecraft missions (orbiters, atmospheric missions, landers, penetrators, and drills); Identification of spacecraft and instrument materials known to be compatible with existing planetary protection protocols; Planetary protection protocols/processes available or which appear promising, and areas ripe for technological development; The technical and engineering challenges in ensuring that spacecraft hardware and instruments can meet organic cleanliness requirements needed to ensure high confidence in differentiating Earth contamination from extraterrestrial signals to avoid false negative as well as false positive results; Approaches for mitigating the identified challenges that would allow instruments to be flown successfully at the required levels of cleanliness and microbial reduction, beginning with identification of commonly used materials and spacecraft hardware that are compatible (or particularly vulnerable) to planetary protection protocols; Engineering, technology, and scientific research and development that could be funded by NASA to provide future capabilities to field scientific instruments and spacecraft on missions that require either subsystem or system-level microbial reduction and recontamination prevention.

John D. Rummel↗

Sensitive Probing of Exoplanetary Oxygen via Mid-Infrared Collisional Absorption

The collision-induced fundamental vibration–rotation band at 6.4 μm is the strongest absorption feature from O2 in the infrared, yet it has not been previously incorporated into exoplanet spectral analyses for several reasons. Either collision-induced absorptions (CIAs) were not included or incomplete/obsolete CIA databases were used. Also, the current version of HITRAN does not include CIAs at 6.4 μm with other collision partners (O2–X). We include O2–X CIA features in our transmission spectroscopy simulations by parameterizing the 6.4-μm O2–N2 CIA based on ref. 3 and the O2–CO2 CIA based on ref. 4. Here we report that the O2–X CIA may be the most detectable O2 feature for transit observations. For a potential TRAPPIST-1 e analogue system within 5 pc of the Sun, it could be the only O2 signature detectable with the James Webb Space Telescope (JWST) (using MIRI LRS (Mid-Infrared Instrument low-resolution spectrometer)) for a modern Earth-like cloudy atmosphere with biological quantities of O2. Also, we show that the 6.4-μm O2–X CIA would be prominent for O2-rich desiccated atmospheres and could be detectable with JWST in just a few transits. For systems beyond 5 pc, this feature could therefore be a powerful discriminator of uninhabited planets with non-biological ‘false-positive’ O2 in their atmospheres, as they would only be detectable at these higher O2 pressures.

Thomas J Fauchez↗

TPSAS-NF1676L-32111-DND

Automated in-situ NDE monitoring of component state during flight or at set increments on ground often requires integrated instrumentation. Challenges: false negatives, false positives; system validation/certification (confidence in detectability, assessment of limitations, and assessment of lifetime).

Elizabeth Gregory↗

The L 98-59 System: Three Transiting, Terrestrial-size Planets Orbiting a Nearby M Dwarf

We report the Transiting Exoplanet Survey Satellite (TESS) discovery of three terrestrial-size planets transiting L98-59 (TOI-175, TIC 307210830)—a bright M dwarf at a distance of 10.6 pc. Using the Gaia-measured distance and broadband photometry, we find that the host star is an M3 dwarf. Combined with the TESS transits from three sectors, the corresponding stellar parameters yield planet radii ranging from 0.8 R⊕ to 1.6 R⊕. All three planets have short orbital periods, ranging from 2.25 to 7.45 days with the outer pair just wide of a 2:1 period resonance. Diagnostic tests produced by the TESS Data Validation Report and the vetting package DAVE rule out common false-positive sources. These analyses, along with dedicated follow-up and the multiplicity of the system, lend confidence that the observed signals are caused by planets transiting L 98-59 and are not associated with other sources in the field. The L 98-59 system is interesting for a number of reasons: the host star is bright (V =11.7 mag, K = 7.1 mag) and the planets are prime targets for further follow-up observations including precision radial-velocity mass measurements and future transit spectroscopy with the James Webb Space Telescope; the near-resonant configuration makes the system a laboratory to study planetary system dynamical evolution; and three planets of relatively similar size in the same system present an opportunity to study terrestrial planets where other variables (age, metallicity, etc.) can be held constant. L 98-59 will be observed in four more TESS sectors, which will provide a wealth of information on the three currently known planets and have the potential to reveal additional planets in the system.

planets↗

The L 98-59 System Three Transiting, Terrestrial-size Planets Orbiting a Nearby M Dwarf

We report the Transiting Exoplanet Survey Satellite (TESS) discovery of three terrestrial-size planets transiting L 98-59 (TOI-175, TIC 307210830)—a bright M dwarf at a distance of 10.6 pc. Using the Gaia-measured distance and broadband photometry, we find that the host star is an M3 dwarf. Combined with the TESS transits from three sectors, the corresponding stellar parameters yield planet radii ranging from 0.8 R⊕ to 1.6 R⊕. All three planets have short orbital periods, ranging from 2.25 to 7.45 days with the outer pair just wide of a 2:1 period resonance. Diagnostic tests produced by the TESS Data Validation Report and the vetting package DAVE rule out common false-positive sources. These analyses, along with dedicated follow-up and the multiplicity of the system, lend confidence that the observed signals are caused by planets transiting L 98-59 and are not associated with other sources in the field. The L 98-59 system is interesting for a number of reasons: the host star is bright (V = 11.7 mag, K = 7.1 mag) and the planets are prime targets for further follow-up observations including precision radial-velocity mass measurements and future transit spectroscopy with the James Webb Space Telescope; the near-resonant configuration makes the system a laboratory to study planetary system dynamical evolution; and three planets of relatively similar size in the same system present an opportunity to study terrestrial planets where other variables (age, metallicity, etc.) can be held constant. L 98-59 will be observed in four more TESS sectors, which will provide a wealth of information on the three currently known planets and have the potential to reveal additional planets in the system.

Veselin B Kostov↗

Sensitive Probing of Exoplanetary Oxygen via Mid-Infrared Collisional Absorption

The collision-induced fundamental vibration–rotation band at 6.4 μm is the strongest absorption feature from O2 in the infrared1,2,3, yet it has not been previously incorporated into exoplanet spectral analyses for several reasons. Either collision-induced absorptions (CIAs) were not included or incomplete/obsolete CIA databases were used. Also, the current version of HITRAN does not include CIAs at 6.4 μm with other collision partners (O2–X). We include O2–X CIA features in our transmission spectroscopy simulations by parameterizing the 6.4-μm O2–N2 CIA based on ref. 3 and the O2–CO2 CIA based on ref. 4. Here we report that the O2–X CIA may be the most detectable O2 feature for transit observations. For a potential TRAPPIST-1 e analogue system within 5 pc of the Sun, it could be the only O2 signature detectable with the James Webb Space Telescope (JWST) (using MIRI LRS (Mid-Infrared Instrument low-resolution spectrometer)) for a modern Earth-like cloudy atmosphere with biological quantities of O2. Also, we show that the 6.4-μm O2–X CIA would be prominent for O2-rich desiccated atmospheres5 and could be detectable with JWST in just a few transits. For systems beyond 5 pc, this feature could therefore be a powerful discriminator of uninhabited planets with non-biological ‘false-positive’ O2 in their atmospheres, as they would only be detectable at these higher O2 pressures.

Thomas Fauchez↗