Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “error localization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 865 records · Page 48

CERN Large hadron collider optics model, measurements, and corrections

Optics stability during all phases of operation is crucial for the LHC. Tools and procedures have been developed for rapid checks of beta beating, dispersion, and linear coupling, as well as for prompt optics corrections. Important optics errors during the different phases of the beam commissioning were observed and locally corrected using the segment-by-segment technique. The most relevant corrections at injection have been corroborated with dedicated magnetic measurements.

43 PARTICLE ACCELERATORS↗

NSTX-U In-Vessel Control Coils’ Design Concept

In this paper, a successful conceptual design was completed to develop in-vessel control coils [non-axisymmetric control coils (NCCs)]. The NCCs are a series of saddle coils that are intended to satisfy a number of physics criteria including magnetic breaking, error field control, fast resistive wall mode (RWM) control, and edge-localized-mode stabilization. Customized mineral-insulated cable (MIC) was selected for the conductor material. The MIC was made from oxygen-free copper conductor, high purity magnesium oxide powder insulation, and 304 stainless steel sleeve cover. Sample MIC was purchased from an outside supplier, and various tests were conducted for design and performance verification including high-voltage testing, which necessitated the development of special test terminations. A concept design was also developed for terminating the MIC ends using the nonconductive and vacuum-sealed technique. Two alternative designs were proposed for joints inside the vacuum vessel (VV). The NCCs are designed to be mounted in front of the primary passive plates and underneath the plasma-facing component (PFC) tiles. The passive plates will be modified to accommodate the coils. A new PFC tile design concept was developed using high-Z materials. New designs for the penetrations through the VV wall were developed. One port per coil was planned. Finally, a new power patch panel will be required to provide the ability for various combinations of connections between the NCC, the existing RWM coils, and the existing switching power amplifier power suppliers.

42 ENGINEERING↗

Concept and simulation study of a novel localization method for robotic endoscopic capsules using multiple positron emission markers

Purpose: Over the last decade, wireless capsule endoscope has been the tool of choice for noninvasive inspection of the gastrointestinal tract, especially in the small intestine. However, the latest clinical products have not been equipped with a sufficiently accurate localization system which makes it difficult to determine the location of intestinal abnormalities, and to apply follow-up interventions such as biopsy or drug delivery. In this paper, the authors present a novel localization method based on tracking three positron emission markers embedded inside an endoscopic capsule. Methods: Three spherical {sup 22}Na markers with diameters of less than 1 mm are embedded in the cover of the capsule. Gamma ray detectors are arranged around a patient body to detect coincidence gamma rays emitted from the three markers. The position of each marker can then be estimated using the collected data by the authors’ tracking algorithm which consists of four consecutive steps: a method to remove corrupted data, an initialization method, a clustering method based on the Fuzzy C-means clustering algorithm, and a failure prediction method. Results: The tracking algorithm has been implemented inMATLAB utilizing simulation data generated from the Geant4 Application for Emission Tomography toolkit. The results show that this localization method can achieve real-time tracking with an average position error of less than 0.4 mm and an average orientation error of less than 2°. Conclusions: The authors conclude that this study has proven the feasibility and potential of the proposed technique in effectively determining the position and orientation of a robotic endoscopic capsule.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Affine Approximation of Parametrized Kernels and Model Order Reduction for Nonlocal and Fractional Laplace Models

In this work, we consider parametrized problems driven by spatially nonlocal integral operators with parameter-dependent kernels. In particular, kernels with varying nonlocal interaction radius $\delta > 0$ and fractional Laplace kernels, parametrized by the fractional power $s\in(0,1)$, are studied. Furthermore, in order to provide an efficient and reliable approximation of the solution for different values of the parameters, we develop the reduced basis method as a parametric model order reduction approach. Major difficulties arise since the kernels are not affine in the parameters, singular, and discontinuous. Moreover, the spatial regularity of the solutions depends on the varying fractional power $s$. To address this, we derive regularity and differentiability results with respect to $\delta$ and $s$, which are of independent interest for other applications such as optimization and parameter identification. We then use these results to construct affine approximations of the kernels by local polynomials. Finally, we certify the method by providing reliable a posteriori error estimators, which account for all approximation errors, and support the theoretical findings by numerical experiments.

97 MATHEMATICS AND COMPUTING↗

High Performance Network Monitoring [Slides]

Network Monitoring requires a substantial use of data and error analysis to overcome issues with clusters. Zenoss and Splunk help to monitor system log messages that are reporting issues about the clusters to monitoring services. Infiniband infrastructure on a number of clusters upgraded to ibmon2. ibmon2 requires different filters to report errors to system administrators. Focus for this summer is to: (1) Implement ibmon2 filters on monitoring boxes to report system errors to system administrators using Zenoss and Splunk; (2) Modify and improve scripts for monitoring and administrative usage; (3) Learn more about networks including services and maintenance for high performance computing systems; and (4) Gain a life experience working with professionals under real world situations. Filters were created to account for clusters running ibmon2 v1.0.0-1 10 Filters currently implemented for ibmon2 using Python. Filters look for threshold of port counters. Over certain counts, filters report errors to on-call system administrators and modifies grid to show local host with issue.

97 MATHEMATICS AND COMPUTING↗

Digital preprocessing of SEASAT imagery

A model for radar image data is derived for use in developing enhancement techniques. This model describes the image data as the result of a multiplicative-convolved noise process. This information is then used to design a minimum mean square error (MMSE) filter. The resulting filter is implemented adaptively to change with local statistics. A radar image processing technique which provides the MMSE estimate inside homogeneous areas and tends to preserve edge structure is thus developed. This technique has been implemented and tested using digitally correlated SEASAT-A synthetic aperture radar (SAR) imagery.

Frost, V. S.↗

A near-optimum receiver structure for the detection of M-ary optical PPM signals

A class of receivers called conditionally nulling receivers is defined for quantum noise limited optical communications. These receivers have the ability to decide at each moment in time whether or not to coherently combine a predetermined local oscillator field with the received optical field, prior to performing an energy measurement (photodetection) on the combined field. Conditionally nulling receivers are applicable to pulse position modulation and related modulation schemes, which have the property that, at each moment in time, the transmitted signal is in one of only two states, on or off. The local oscillator field which may or may not be added by the receiver is an exact replica of the negative of the received on field; hence, the receiver can exactly null the on signal if the on signal is present and the receiver chooses to use the local field. An ideal conditionally nulling receiver achieves very nearly the same error probability (within a multiplicative factor varying froom 1 to 2.15) as the optimum quantum measurement for quantum noise limited detection of M-ary PPM signals. In contrast, other known receiving methods, such as direct, heterodyne, and homodyne detection, are exponentially suboptimum.

Dolinar, S. J., Jr.↗

A climatically-derived global soil moisture data set for use in the GLAS atmospheric circulation model seasonal cycle experiment

Algorithms for point interpolation and contouring on the surface of the sphere and in Cartesian two-space are developed from Shepard's (1968) well-known, local search method. These mapping procedures then are used to investigate the errors which appear on small-scale climate maps as a result of the all-too-common practice of of interpolating, from irregularly spaced data points to the nodes of a regular lattice, and contouring Cartesian two-space. Using mean annual air temperatures field over the western half of the northern hemisphere is estimated both on the sphere, assumed to be correct, and in Cartesian two-space. When the spherically- and Cartesian-approximted air temperature fields are mapped and compared, the magnitudes (as large as 5 C to 10 C) and distribution of the errors associated with the latter approach become apparent.

Willmott, C. J.↗

Morphology and development of organized convection in the boundary layer

Vector windspeed measurements in a horizontal plane are derived from an airborne Doppler lidar. Error correction has improved so that those which remain do not affect local flow analysis. This allows measurements of wave structures in and near the boundary layer. Deep boundary layer measurements show pronounced interacting wave structures. Wave structures were also observed to result from obstacle flow.

Lee, R. W.↗

Face-gear drives: Design, analysis, and testing for helicopter transmission applications

The use of face-gears in helicopter transmissions was explored. A light-weight, split-torque transmission design utilizing face-gears is described. Face-gear design and geometry were investigated. Topics included tooth generation, limiting inner and outer radii, tooth contact analysis, contact ratio, gear eccentricity, grinding, and structural stiffness. Design charts were developed to determine minimum and maximum face-gear inner and outer radii. An analytical study showed that the face-gear drive is relatively insensitive to gear misalignment with respect to transmission errors, but the tooth contact is affected by misalignment. A method of localizing the bearing contact to permit operation with misalignment was explored. Two new methods for grinding of the face-gear tooth surfaces were also investigated. The proper choice of shaft stiffness enabled good load sharing in the split-torque transmission design. Face-gear experimental studies were also conducted. These tests demonstrated the feasibility of face-gears in high-speed, high-load applications such as helicopter transmissions.

Litvin, F. L.↗

Global reference frame: Intercomparison of results (SLR, VLBI and GPS)

The terrestrial reference frame (TRF) is realized by a set of positions and velocities derived from a combination of the three space geodetic techniques, SLR, VLBI and GPS. The standard International TRF is constructed by the International Earth Rotation Service in such a way that it is stable with time and the addition of new data. An adopted model for overall plate motion, NUVEL-1 NNR, defines the conceptual reference frame in which all the plates are moving. In addition to the measurements made between reference points within the space geodetic instruments, it is essential to have accurate, documented eccentricity measurements from the instrument reference points to ground monuments. Proper local surveys between the set of ground monuments at a site are also critical for the use of the space geodetic results. Eccentricities and local surveys are, in fact, the most common and vexing sources of error in the use of the TRF for such activities as collocation and intercomparison.

Ma, Chopo↗

The luminosity function of the CfA Redshift Survey

We use the CfA Reshift Survey of galaxies with m(sub z) less than or equal to 15.5 to calculate the galaxy luminosity function over the range -13 less than or equal to M(sub z) less than or equal to -22. The sample includes 9063 galaxies distributed over 2.1 sr. For galaxies with velocities cz greater or equal to 2500 km per sec, where the effects of peculiar velocities are small, the luminosity function is well represented by a Schechter function with parameters phi(sub star) = 0.04 +/- 0.01 per cu Mpc, M(sub star) = -18.8 +/- 0.3, and alpha = -1.0 +/- 0.2. When we include all galaxies with cz greater or equal to 500 km per sec, the number of galaxies in the range -16 less than or equal to M(sub z) less than or equal to -13 exceeds the extrapolation of the Schechter function by a factor of 3.1 +/- 0.5. This faint-end excess is not caused by the local peculiar velocity field but may be partially explained by small scale errors in the Zwicky magnitudes. Even with a scale error as large as 0.2 mag per mag, which is unlikely, the excess is still a factor of 1.8 +/- 0.3. If real, this excess affects the interpretation of deep counts of field galaxies.

Marzke, R. O.↗

Displacement Compensation of Temperature Probe Data

Analysis of temperature data from a probe in a vertical Bridgman furnace growing germanium crystals revealed a displacement of the temperature profile due to conduction error. A theoretical analysis shows that the displacement compensation is independent of local temperature gradient. A displacement compensation value should become a standard characteristic of temperature probes used for temperature profile measurements.

Welch, Christopher S.↗

Design and Integration of an All-Magnetic Attitude Control System for FASTSAT-HSV01's Multiple Pointing Objectives

The FASTSAT-HSV01 spacecraft is a microsatellite with magnetic torque rods as it sole attitude control actuator. FASTSAT s multiple payloads and mission functions require the Attitude Control System (ACS) to maintain Local Vertical Local Horizontal (LVLH)-referenced attitudes without spin-stabilization, while the pointing errors for some attitudes be significantly smaller than the previous best-demonstrated for this type of control system. The mission requires the ACS to hold multiple stable, unstable, and non-equilibrium attitudes, as well as eject a 3U CubeSat from an onboard P-POD and recover from the ensuing tumble. This paper describes the Attitude Control System, the reasons for design choices, how the ACS integrates with the rest of the spacecraft, and gives recommendations for potential future applications of the work.

DeKock, Brandon↗

Measurements of Aperture Averaging on Bit-Error-Rate

We report on measurements made at the Shuttle Landing Facility (SLF) runway at Kennedy Space Center of receiver aperture averaging effects on a propagating optical Gaussian beam wave over a propagation path of 1,000 in. A commercially available instrument with both transmit and receive apertures was used to transmit a modulated laser beam operating at 1550 nm through a transmit aperture of 2.54 cm. An identical model of the same instrument was used as a receiver with a single aperture that was varied in size up to 20 cm to measure the effect of receiver aperture averaging on Bit Error Rate. Simultaneous measurements were also made with a scintillometer instrument and local weather station instruments to characterize atmospheric conditions along the propagation path during the experiments.

Bastin, Gary L.↗

An efficient decoder for a linear distance quantum LDPC code

Recent developments have shown the existence of quantum low-density parity check (qLDPC) codes with constant rate and linear distance. A natural question concerns the efficient decodability of these codes. In this paper, we present a linear time decoder for the recent quantum Tanner codes construction of asymptotically good qLDPC codes, which can correct all errors of weight up to a constant fraction of the blocklength. Our decoder is an iterative algorithm which searches for corrections within constant-sized regions. At each step, the corrections are found by reducing a locally defined and efficiently computable cost function which serves as a proxy for the weight of the remaining error.

97 MATHEMATICS AND COMPUTING↗

High Precision In-Pipe Robot Localization with Reciprocal Sensor Fusion - 19516

Manual measurement of U-235 deposits in uranium enrichment piping is a costly, time consuming, and labor-intensive process that is a well-known cost and schedule driver. Autonomous, robotic innovation enabled by this research is revolutionizing the measurement speed, quality and safety of this important operation. The huge advantage is the robot's ability to measure from inside the pipes. The upside is sensing the geometry, appearance and radiometry directly. The downside is the inability to know precise, absolute position of the measurements in very long pipe runs. This paper develops the unprecedented localization required for this purpose. This paper presents the precise localization method designed for in-pipe radiation measurement robots. Unlike other in-pipe localization methods, this approach achieves millimeter-level accuracy in hundred-foot runs and does everything on one robot without relying on tether cable or communicating devices out of pipe, which is an important feature for nuclear in-pipe robot. It overcomes challenges usually encountered by in-pipe localization such as long travelling distance and operation time, narrow view angle, and featureless environment. The robot is equipped with encoders embedded in tracks which can record travelled distance, but encoder odometry drifts unacceptably due to slip and non-linearity. The robot also incorporates a laser range finder measuring the absolute distance, but range finder in long pipes has many misleading false measurements that are difficult to filter. The innovation here is to use one to filter/calibrate the other so that data used from the two sensors improve each other iteratively and reciprocally. The survey measurements accuracy of this localization method is proven by experiments comparing to ground truth and 'Zippering error' experiments that compare measurements to fixed features in pipes. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

The FIELDS Instrument Suite on MMS: Scientific Objectives, Measurements, and Data Products

The FIELDS instrumentation suite on the Magnetospheric Multiscale (MMS) mission provides comprehensive measurements of the full vector magnetic and electric fields in the reconnection regions investigated by MMS, including the dayside magnetopause and the night-side magnetotail acceleration regions out to 25 Re. Six sensors on each of the four MMS spacecraft provide overlapping measurements of these fields with sensitive cross-calibrations both before and after launch. The FIELDS magnetic sensors consist of redundant flux-gate magnetometers (AFG and DFG) over the frequency range from DC to 64 Hz, a search coil magnetometer (SCM) providing AC measurements over the full whistler mode spectrum expected to be seen on MMS, and an Electron Drift Instrument (EDI) that calibrates offsets for the magnetometers. The FIELDS three-axis electric field measurements are provided by two sets of biased double-probe sensors (SDP and ADP) operating in a highly symmetric spacecraft environment to reduce significantly electrostatic errors. These sensors are complemented with the EDI electric measurements that are free from all local spacecraft perturbations. Cross-calibrated vector electric field measurements are thus produced from DC to 100 kHz, well beyond the upper hybrid resonance whose frequency provides an accurate determination of the local electron density. Due to its very large geometric factor, EDI also provides very high time resolution (∼1 ms) ambient electron flux measurements at a few selected energies near 1 keV. This paper provides an overview of the FIELDS suite, its science objectives and measurement requirements, and its performance as verified in calibration and cross-calibration procedures that result in anticipated errors less than 0.1 nT in B and 0.5 mV/m in E. Summaries of data products that result from FIELDS are also described, as well as algorithms for cross-calibration. Details of the design and performance characteristics of AFG/DFG, SCM, ADP, SDP, and EDI are provided in five companion papers.

Electromagnetic field measurements↗