Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “error indicators”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 865 records · Page 48

Correlations between Salt-Induced Crystallization, Morphology, Segmental Dynamics, and Conductivity in Amorphous Block Copolymer Electrolytes

Block copolymer electrolytes have been shown to increase the cycle life of rechargeable batteries that utilize high capacity lithium anodes. Most block copolymer electrolyte studies have been centered on polystyrene-b-poly(ethylene oxide) (SEO) mixed with lithium bis(trifluoromethanesulfonyl)imide (LiTFSI) salt and are limited to salt concentrations in the vicinity of r[Li]/[EO] = 0.1, where [Li] and [EO] are the concentration of lithium and ethylene oxide moieties, respectively, as the conductivity of poly(ethylene oxide) (PEO) homopolymer electrolytes is maximized at this concentration.Here, in this paper, we study the morphology and conductivity of electrolytes derived from a high molecular weight SEO block copolymer over the wide LiTFSI concentration range of 0 ≤ r ≤ 0.550. For electrolytes with r ≥ 0.125, the crystallization of PEO-LiTFSI complexes with stoichiometric ratios of 6:1, 3:1, or 2:1 (EO:Li) is shown to correlate with morphology as determined by small-angle X-ray scattering (SAXS) and scanning transmission electron microscopy (STEM): some samples that are semicrystalline at room temperature exhibit regions of periodic lamellar ordering, whereas those that do not crystallize have aperiodic packed-ellipsoid morphologies. SAXS profiles below and above the melting temperatures of the crystals are identical, indicating that the crystals are confined within the block copolymer domains. The conductivities of SEO/LiTFSI mixtures with r = 0.275, r = 0.300, and r = 0.350 are within experimental error of PEO/LiTFSI at the same salt concentrations, in spite of the presence of insulating polystyrene (PS) domains in the SEO/LiTFSI samples. We attribute this to enhanced segmental dynamics of the PEO chains in the SEO electrolytes, based on differential scanning calorimetry (DSC) measurements of glass transition temperatures. The dependence of ionic conductivity on salt concentration in the SEO/LiTFSI electrolytes at temperatures above the melting temperature of the crystalline complexes shows three local maxima that correlate with the formation of crystalline complexes when r ≥ 0.125. Finally, these maxima arise due to a combination of the enhanced segmental dynamics and changes in morphology observed by SAXS and STEM.

36 MATERIALS SCIENCE↗

A new dump system design for stray light reduction of Thomson scattering diagnostic system on EAST

Thomson scattering (TS) diagnostic is an important diagnostic for measuring electron temperature and density during plasma discharge. However, the measurement of Thomson scattering signal is disturbed by the stray light easily. The stray light sources in the Experimental Advanced Superconducting Tokamak (EAST) TS diagnostic system were analyzed by a simulation model of the diagnostic system, and simulation results show that the dump system is the primary stray light source. Based on the optics theory and the simulation analysis, a novel dump system including an improved beam trap was proposed and installed. The measurement results indicate that the new dump system can reduce more than 60% of the stray light for the diagnostic system, and the influence of stray light on the error of measured density decreases.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SARAS MEASUREMENT OF THE RADIO BACKGROUND AT LONG WAVELENGTHS

SARAS is a correlation spectrometer connected to a frequency independent antenna that is purpose-designed for precision measurements of the radio background at long wavelengths. The design, calibration, and observing strategies admit solutions for the internal additive contributions to the radiometer response, and hence a separation of these contaminants from the antenna temperature. We present here a wideband measurement of the radio sky spectrum by SARAS that provides an accurate measurement of the absolute brightness and spectral index between 110 and 175 MHz. Accuracy in the measurement of absolute sky brightness is limited by systematic errors of magnitude 1.2%; errors in calibration and in the joint estimation of sky and system model parameters are relatively smaller. We use this wide-angle measurement of the sky brightness using the precision wide-band dipole antenna to provide an improved absolute calibration for the 150 MHz all-sky map of Landecker and Wielebinski: subtracting an offset of 21.4 K and scaling by a factor of 1.05 will reduce the overall offset error to 8 K (from 50 K) and scale error to 0.8% (from 5%). The SARAS measurement of the temperature spectral index is in the range −2.3 to −2.45 in the 110–175 MHz band and indicates that the region toward the Galactic bulge has a relatively flatter index.

79 ASTRONOMY AND ASTROPHYSICS↗

Improvement of the RELAP5-3D Model of Condensation in the Presence of Noncondensables

Condensation of steam on the primary side of a steam generator in a pressurized water reactor (PWR) is one means of removing decay heat during some accident scenarios, including small break loss of coolant accident (SBLOCA). However, when noncondensable gasses mix with steam, it impairs condensation. To correctly predict plant behavior, nuclear power plant (NPP) safety analysis codes such as RELAP5-3D must model the effect of condensation in the presence of noncondensables properly. A potential error in the RELAP5-3D code was reported in the condensation model in the presence of noncondensables by the University of Wisconsin (Fu 2015). The report indicated that the calculated condensation heat flux was under-predicted due to the modeling of the mass transfer in the gas mixture. The original documentation describing the implementation of the model was reviewed and compared with alternative formulations. An alternative that uses saturation vapor density at temperature of total pressure instead of the saturation vapor density at vapor partial pressure for calculating vapor mass flux was implemented. Comparison of the alternative method with the original against experimental data for several test cases showed improvement for most test cases.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

CCSI Toolset 3.22 Release

CCSI Toolset 3.22 Release Highlights The Sequential Design of Experiments user interface was updated to resolve an issue where the results would fail to plot in some cases (e.g., Non-Uniform Space Filling designs). The Machine Learning/Artificial Intelligence module was updated to support Keras 3 and to reflect changes made to dependencies’ syntax. A check was added to ensure PSUADE is installed and available at FOQUS startup. If PSUADE is not installed, a link to the FOQUS documentation is displayed and FOQUS is closed. The copyright year was updated to include 2024 in places where it had not previously been updated. Typographical errors were corrected to improve clarity in variable names and documentation. The FOQUS documentation was updated to reflect the fact that ALAMO can have two executables and indicates the correct executable to add to the Settings path. SimSinter was updated to version 3.1.0. This version removed gPROMS support and included security updates.

AS↗

Validation of the Five-Phase Method for Simulating Complex Fenestration Systems with Radiance against Field Measurements

The Five-Phase Method (5-pm) for simulating complex fenestration systems with Radiance is validated against field measurements. The capability of the method to predict workplane illuminances, vertical sensor illuminances, and glare indices derived from captured and rendered high dynamic range (HDR) images is investigated. To be able to accurately represent the direct sun part of the daylight not only in sensor point simulations, but also in renderings of interior scenes, the 5-pm calculation procedure was extended. The validation shows that the 5-pm is superior to the Three-Phase Method for predicting horizontal and vertical illuminance sensor values as well as glare indices derived from rendered images. Even with input data from global and diffuse horizontal irradiance measurements only, daylight glare probability (DGP) values can be predicted within 10% error of measured values for most situations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Caffeine Use among Active Duty Navy and Marine Corps Personnel

Data from the National Health and Nutrition Examination Survey (NHANES) indicate 89% of Americans regularly consume caffeine, but these data do not include military personnel. This cross-sectional study examined caffeine use in Navy and Marine Corps personnel, including prevalence, amount of daily consumption, and factors associated with use. A random sample of Navy and Marine Corps personnel was contacted and asked to complete a detailed questionnaire describing their use of caffeine-containing substances, in addition to their demographic, military, and lifestyle characteristics. A total of 1708 service members (SMs) completed the questionnaire. Overall, 87% reported using caffeinated beverages ≥1 time/week, with caffeine users consuming a mean ± standard error of 226 ± 5 mg/day (242 ± 7 mg/day for men, 183 ± 8 mg/day for women). The most commonly consumed caffeinated beverages (% users) were coffee (65%), colas (54%), teas (40%), and energy drinks (28%). Multivariable logistic regression modeling indicated that characteristics independently associated with caffeine use (≥1 time/week) included older age, white race/ethnicity, higher alcohol consumption, and participating in less resistance training. Prevalence of caffeine use in these SMs was similar to that reported in civilian investigations, but daily consumption (mg/day) was higher.

60 APPLIED LIFE SCIENCES↗

Influence of intermolecular interactions on the infrared complex indices of refraction for binary liquid mixtures

This paper investigates the accuracy of deriving the composite optical constants of binary mixtures from only the complex indices of refraction of the neat materials. These optical constants enable the reflectance spectra of the binary mixtures to be modeled for multiple scenarios (e.g., different substrates, thicknesses, volume ratios), which is important for contact and standoff chemical detection. Using volume fractions, each mixture's complex index of refraction was approximated via three different mixing rules. To explore the impact of intermolecular interactions, these predictions are tested by experimental measurements for two representative sets of binary mixtures: (1) tributyl phosphate combined with n-dodecane, a non-polar medium, to represent mixtures which primarily interact via dispersion forces and (2) tributyl phosphate and 1-butanol to represent mixtures with polar functional groups that can also interact via dipole–dipole interactions, including hydrogen bonding. The residuals and the root-mean-square error between the experimental and calculated index values are computed and demonstrate that for miscible liquids in which the average geometry of the cross-interactions can be considered isotropic (e.g., dispersion), the refractive indices of the mixtures can be modeled using composite n and k values derived from volume fractions of the neat liquids. Conversely, in spectral regions where the geometry of the cross-interactions is more restricted and anisotropic (e.g., hydrogen bonding), the calculated n and k values vary from the measured values. The impact of these interactions on the reflectance spectra are then compared by modeling a thin film of the binary mixtures on an aluminum substrate using both the measured and the mathematically computed indices of refraction.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Estimating Field-Level Perennial Bioenergy Grass Biomass Yields Using the Normalized Difference Red-Edge Index and Linear Regression Analysis for Central Virginia, USA

We investigated the indicative power of the normalized difference red-edge index (NDRE) for estimating field-level perennial bioenergy grass biomass yields utilizing Sentinel-2 imagery and a linear regression model as a rapid, cost-effective method for biomass yield estimations for bioenergy. We used 2019 data from three study sites containing mature perennial bioenergy grass stands in central Virginia, USA. Of the simulated daily NDRE values based on the temporally weighted averaging of two temporal neighbors, we found the strongest index–yield correlation on 11 August (R = 0.85). We estimated the perennial bioenergy grass biomass yields for (1) all sites using the data pooled from the three sites (all-site estimation) and (2) each site using the data pooled from the other two sites (cross-site estimation). The estimated field-level perennial bioenergy grass biomass yields strongly correlated with the recorded yields (average R2 = 0.76), with a root mean square error (RMSE) of 1.5 Mg/ha and a mean absolute error (MAE) of 1.2 Mg/ha for the all-site estimation. For the cross-site estimation, the site with diverse perennial grass types had the weakest correlation (R2 = 0.44) of the sites, indicating a difficulty in accounting for heterogeneous index–yield relationships in a single model. In addition to identifying a strong indicative power of the NDRE for estimating the overall perennial bioenergy grass biomass yields at a field level, the findings from this study call for an analysis across multiple perennial grasses and a comparison using multiple sites to understand (1) if the indicative power of the index shifts from the biomass of the specific perennial bioenergy grass type to the overall biomass during the growing season and (2) the level of perennial bioenergy grass heterogeneity that may hinder the remotely sensed biomass yield estimation using a single model.

09 BIOMASS FUELS↗

ON THE DISTANCE OF THE MAGELLANIC CLOUDS USING CEPHEID NIR AND OPTICAL-NIR PERIOD-WESENHEIT RELATIONS

We present the largest near-infrared (NIR) data sets, JHKs, ever collected for classical Cepheids in the Magellanic Clouds (MCs). We selected fundamental (FU) and first overtone (FO) pulsators, and found 4150 (2571 FU, 1579 FO) Cepheids for Small Magellanic Cloud (SMC) and 3042 (1840 FU, 1202 FO) for Large Magellanic Cloud (LMC). Current sample is 2-3 times larger than any sample used in previous investigations with NIR photometry. We also discuss optical VI photometry from OGLE-III. NIR and optical-NIR Period-Wesenheit (PW) relations are linear over the entire period range (0.0 < log P {sub FU} {<=} 1.65) and their slopes are, within the intrinsic dispersions, common between the MCs. These are consistent with recent results from pulsation models and observations suggesting that the PW relations are minimally affected by the metal content. The new FU and FO PW relations were calibrated using a sample of Galactic Cepheids with distances based on trigonometric parallaxes and Cepheid pulsation models. By using FU Cepheids we found a true distance moduli of 18.45 {+-} 0.02(random) {+-} 0.10(systematic) mag (LMC) and 18.93 {+-} 0.02(random) {+-} 0.10(systematic) mag (SMC). These estimates are the weighted mean over 10 PW relations and the systematic errors account for uncertainties in the zero point and in the reddening law. We found similar distances using FO Cepheids (18.60 {+-} 0.03(random) {+-} 0.10(systematic) mag (LMC) and 19.12 {+-} 0.03(random) {+-} 0.10(systematic) mag (SMC)). These new MC distances lead to the relative distance, {Delta}{mu} = 0.48 {+-} 0.03 mag (FU, log P = 1) and {Delta}{mu} = 0.52 {+-} 0.03 mag (FO, log P = 0.5), which agrees quite well with previous estimates based on robust distance indicators.

79 ASTRONOMY AND ASTROPHYSICS↗

Managing systematic errors in the NBSR thermal power calorimetric measurements - 214

There has been a calorimetric misbalance between the primary and secondary loops of the National Bureau of Standards Reactor (NBSR) since the installation of a set of new heat exchangers in the early 90's. The NBSR's primary and secondary process instrumentation were investigated to resolve the underlying causes. The main issue was found to be the immersion length of the thermowells, resulting in non-exemplary process measurements. Furthermore, thermal insulation on various temperature sensors was found to be degraded. Hence, the following were found to be inconsistent: the heat exchanger output temperatures, previously-used differential temperature sensors, reactor inlet sensor, and the reactor outlet temperature indications. Therefore, thermodynamic analyses using these sensor measurements were inconclusive. Secondly, the discrepancy between primary and secondary loops and the gradual inconsistency between primary side sensors went largely unnoticed. We implemented sustainable, state-of-the-art upgrades to resolve systematic errors in the NBSR reactor thermal process instrumentation. Several digital upgrades were completed, along with detailed 50.59 reviews. Redundancy, defense-in-depth, reliability, diversity and accuracy of the thermal monitoring system was established by implementing an inclusive engineering approach by analyzing the sensors as a whole system instead of individual assessments. The upgrades produced two important outcomes. First, the long-term existing calorimetric discrepancy between the primary and secondary loops was resolved. Secondly, excellent agreement was achieved within the primary process measurement instrumentation, resulting in reliable and stable thermal power assessment. We will present lessons learned performing instrumentation upgrades and our future enhancement plans in process monitoring for the NBSR reactor. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

A side‐by‐side comparison of CPV module and system performance

Abstract A side‐by‐side comparison is made between concentrator photovoltaic module and system direct current aperture efficiency data with a focus on quantifying system performance losses. The individual losses measured/calculated, when combined, are in good agreement with the total loss seen between the module and the system. Results indicate that for the given test period, the largest individual loss of 3.7% relative is due to the baseline performance difference between the individual module and the average for the 200 modules in the system. A basic empirical model is derived based on module spectral performance data and the tabulated losses between the module and the system. The model predicts instantaneous system direct current aperture efficiency with a root mean square error of 2.3% relative. Copyright © 2016 John Wiley & Sons, Ltd.

Muller, Matthew↗

Synchronizing spatio-temporal chaos with imperfect models: A stochastic surface growth picture

We study the synchronization of two spatially extended dynamical systems where the models have imperfections. We show that the synchronization error across space can be visualized as a rough surface governed by the Kardar-Parisi-Zhang equation with both upper and lower bounding walls corresponding to nonlinearities and model discrepancies, respectively. Two types of model imperfections are considered: parameter mismatch and unresolved fast scales, finding in both cases the same qualitative results. The consistency between different setups and systems indicates that the results are generic for a wide family of spatially extended systems.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Interlaboratory Study of Digital Volume Correlation Error Due to X-Ray Computed Tomography Equipment and Scan Parameters: an Update from the DVC Challenge

Background: The quality of Digital Volume Correlation (DVC) full-field displacement measurements depends directly on the characteristics of the X-ray Computed Tomography (XCT) equipment, and scan procedures used to acquire the tomographic images. Objective: In this work, we seek to experimentally study the effects of XCT equipment and tomographic scan procedures on the quality of these images for DVC analysis, and to survey the level of DVC error that may be achieved using standard XCT operating procedures. Methods: Six participants in an interlaboratory study acquired high-quality XCT scans of a syntactic foam before and after rigid body motion. The resulting images were correlated using commercial DVC software to quantify error sources due to random image noise, reconstruction artifacts, as well as systematic spatial or temporal distortion. Results: In the absence of rigid body motion, the standard deviation of the displacement measurements ranged from 0.012 to 0.043 voxels using a moderate subvolume size, indicating that subvoxel measurement resolution could readily be achieved with a variety of XCT equipment and scan recipes. Comparison of consecutive scans without rigid body motion showed transient dilatational displacement gradients due to self-heating of the X-ray source and/or thermal expansion of the foam. Evaluation of the scans after rigid body motion showed significant, machine-specific spatial distortion in the displacement fields of up to 0.5 voxels; new approaches to remove this error need to be developed. Conclusions: Analysis of the scan protocols used in the interlaboratory study, as well as a complementary parametric sensitivity study, showed that the DVC error was strongly influenced by the XCT equipment, but could be mitigated by adjusting the total scan duration.

47 OTHER INSTRUMENTATION↗

Polarization Transfer in Wide-Angle Compton Scattering and Single-Pion Photoproduction from the Proton

Wide-angle exclusive Compton scattering and single-pion photoproduction from the proton have been investigated via measurement of the polarization transfer from a circularly polarized photon beam to the recoil proton. The wide-angle Compton scattering polarization transfer was analyzed at an incident photon energy of 3.7 GeV at a proton scattering angle of theta(p)(cm) cm = 70 degrees. The longitudinal transfer K-LL, measured to be 0.645 +/- 0.059 +/- 0.048, where the first error is statistical and the second is systematic, has the same sign as predicted for the reaction mechanism in which the photon interacts with a single quark carrying the spin of the proton. However, the observed value is similar to 3 times larger than predicted by the generalized-parton-distribution-based calculations, which indicates a significant unknown contribution to the scattering amplitude.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

TU-H-CAMPUS-JeP3-01: Towards Robust Adaptive Radiation Therapy Strategies

Purpose: To set up a framework combining robust treatment planning with adaptive reoptimization in order to maintain high treatment quality, to respond to interfractional variations and to identify those patients who will benefit the most from an adaptive fractionation schedule. Methods: We propose adaptive strategies based on stochastic minimax optimization for a series of simulated treatments on a one-dimensional patient phantom. The plan should be able to handle anticipated systematic and random errors and is applied during the first fractions. Information on the individual geometric variations is gathered at each fraction. At scheduled fractions, the impact of the measured errors on the delivered dose distribution is evaluated. For a patient that receives a dose that does not satisfy specified plan quality criteria, the plan is reoptimized based on these individual measurements using one of three different adaptive strategies. The reoptimized plan is then applied during future fractions until a new scheduled adaptation becomes necessary. In the first adaptive strategy the measured systematic and random error scenarios and their assigned probabilities are updated to guide the robust reoptimization. The focus of the second strategy lies on variation of the fraction of the worst scenarios taken into account during robust reoptimization. In the third strategy the uncertainty margins around the target are recalculated with the measured errors. Results: By studying the effect of the three adaptive strategies combined with various adaptation schedules on the same patient population, the group which benefits from adaptation is identified together with the most suitable strategy and schedule. Preliminary computational results indicate when and how best to adapt for the three different strategies. Conclusion: A workflow is presented that provides robust adaptation of the treatment plan throughout the course of treatment and useful measures to identify patients in need for an adaptive treatment strategy.

60 APPLIED LIFE SCIENCES↗

A novel approach to evaluate soil heat flux calculation: An analytical review of nine methods

Abstract There are no direct methods to evaluate calculated soil heat flux (SHF) at the surface ( G 0 ). Instead, validation and cross evaluation of methods for calculating G 0 usually rely on the conventional calorimetric method or the degree of the surface energy balance closure. However, there is uncertainty in the calorimetric method itself, and factors apart from G 0 also contribute to nonclosure of the surface energy balance. Here we used a novel approach to evaluate nine different methods for calculating SHF, including the calorimetric method and methods based on analytical solutions of the heat diffusion equation. The SHF ( G z ) measured by a self‐calibrating SHF plate at a depth of z = 5 cm below the surface (hereafter G m _5 cm ) was deployed as a reference. Each SHF calculation method was assessed by comparing the calculated G z at the same depth (hereafter G c _5 cm ) with G m _5 cm . The calorimetric method and simple measurement method performed best in determining G c _5 cm but still underestimated G m _5 cm by 19% during the daytime. Possible causes for this underestimation include errors and uncertainties in SHF measurements and soil thermal properties, as well as the phase lag between G c _5 cm and G m _5 cm . Our results indicate that the calorimetric method achieves the most accurate SHF estimates if self‐calibrating SHF plates are deployed at two depths (e.g., 5 cm and 10 cm), soil temperature and water content measurements are made in a few depths between the two plates, and soil thermal properties are accurately quantified.

Gao, Zhongming↗

Harmonizing direct and indirect anthropogenic land carbon fluxes indicates a substantial missing sink in the global carbon budget since the early 20th century

Inconsistencies in the calculation of the two anthropogenic land flux terms of the global carbon cycle are investigated. The two terms—the direct anthropogenic flux (caused by direct human disturbance in anthromes, currently a carbon source to the atmosphere) and the indirect anthropogenic flux (caused indirectly by human activities that lead to global change and affecting all biomes, currently an atmospheric carbon sink)—are typically calculated independently, resulting in inconsistent underlying assumptions. We harmonize the estimation of the two anthropogenic land flux terms by incorporating previous estimates of these inconsistencies. We recalculate the global carbon budget (GCB) and apply change-point analysis to the cumulative budget imbalance. Cumulative over 1850–2018 (1959–2018), harmonization results in a 13% lesser (4% greater) land use source from anthromes and a 20% (23%) lesser land sink. This recalculation yields a greater non-closure of the GCB, indicating a missing carbon sink averaging 0.65 Pg C year -1 since the early 20th century. The imbalance likely results from a combination of method discontinuity and structural errors in the assessment of the direct anthropogenic land use flux, greater ocean carbon uptake, structural errors in land models, and in how these land terms are quantified for the budget. We caution against overconfidence in considering the GCB a solved problem and recommend further study of methodological discontinuities in budget terms. We strongly recommend studies that quantify the direct and indirect anthropogenic land fluxes simultaneously to ensure consistency, with a deeper understanding of human disturbance and legacy effects in anthromes.

54 ENVIRONMENTAL SCIENCES↗