Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “electronic noise”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 865 records · Page 48

Detection of atomic oxygen and its electronic coherence decays using time-resolved ultrafast coherent Raman scattering

We report the detection of atomic oxygen and quantitative measurements of its electronic Raman coherence decays in flames and low-temperature plasmas using time-resolved hybrid femtosecond/picosecond coherent anti-Stokes Raman scattering (CARS). Atomic oxygen was detected using the Raman transitions between the spin–orbit coupled triplet ground states. Atomic oxygen was generated in an H 2 /O 2 /Ar diffusion flame and an O 2 /Ar pulsed plasma discharge. Single exponential decays were observed for the O( 3 P 2 )–O( 3 P 1 ) Raman transition at 158.3 cm −1 and the O( 3 P 2 )–O( 3 P 0 ) Raman transition at 227 cm −1 . From the decay measurements, the atomic O Raman linewidths were obtained from 25 to 150 Torr in non-equilibrium plasma and at 760 Torr in a flame. Enhanced signal-to-noise ratios (SNRs) of atomic oxygen and atomic to molecular oxygen signal contrasts were obtained by taking advantage of electronic triplet coherence beating. Enhancement of up to seven times in the atomic O SNR was observed. Furthermore, we also found that the dephasing rates of O 2 (v = 0–3, N = 37) were similar, which provides evidence for the assumption that vibrational excitation does not influence the dephasing of diatomic molecular rotational CARS transitions.

Atomic and molecular spectroscopy↗

The ICEBERG Test Stand for DUNE Cold Electronics Development

ICEBERG is a liquid argon time projection chamber at Fermilab for the purpose of testing detector components and software for the Deep Underground Neutrino Experiment (DUNE). The detector features a 1.15m x 1m anode plane following the specifications of the DUNE horizontal drift far detector and a newly installed X-ARAPUCA photodetector. The status of ICEBERG is reported along with analysis of noise, pulser, and cosmic ray data from the ninth run beginning May 2024 with the goal of advising the DUNE collaboration on the optimal wire readout electronics configuration. In addition, development of an absolute energy scale calibration method is currently underway using known sources such as cosmic ray muon Michel electrons at the ~10 MeV scale and $^{39}$Ar decay electrons at the ~100keV scale. Research into AI-based identification of such events at the data acquisition level is introduced.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

TES Detector Noise Limited Readout Using SQUID Multiplexers

The availability of superconducting Transition Edge Sensors (TES) with large numbers of individual detector pixels requires multiplexers for efficient readout. The use of multiplexers reduces the number of wires needed between the cryogenic electronics and the room temperature electronics and cuts the number of required cryogenic amplifiers. We are using an 8 channel SQUID multiplexer to read out one-dimensional TES arrays which are used for submillimeter astronomical observations. We present results from test measurements which show that the low noise level of the SQUID multiplexers allows accurate measurements of the TES Johnson noise, and that in operation, the readout noise is dominated by the detector noise. Multiplexers for large number of channels require a large bandwidth for the multiplexed readout signal. We discuss the resulting implications for the noise performance of these multiplexers which will be used for the readout of two dimensional TES arrays in next generation instruments.

Staguhn, J. G.↗

Rocket observations of electron density in the nighttime E region using Faraday rotation

A rocket radio propagation experiment is described in which the electron density profile of the nighttime E region is obtained with an accuracy of 100 per cu cm. The factors limiting the accuracy of the experiment are found to be related to atmospheric and receiver noise and to the use of a magnetometer to determine the spin rate of the rocket. The Fourier analysis used for the frequency measurement may also contribute error under conditions of steep electron density gradients. The accuracy being achieved appears to be adequate for present applications of the experiment.

Smith, L. G.↗

Radio Science System Design and Measurement Results for the NASA Deep Space Network (DSN)

Radio science measurements have been performed using the NASA Deep Space Network (DSN) with many different spacecraft over several decades. Radio science has been used for the study of planetary atmospheres, the solar corona and the search for gravity waves, among other things. The majority of these measurements are made using the X and Ka-band deep space bands. Although the primary mission for the DSN is tracking, telemetry and command (TT&C) for NASA’s many deep-space spacecraft, radio science measurements continue to be an important secondary mission. The science requirements for these measurements have resulted in stringent performance requirements for both the spacecraft and ground system equipment. In particular, the requirements for amplitude stability, phase stability (Allen deviation) and phase noise are very demanding. The system Allen deviation requirement at Ka-band is < 2.4 E-15 over 1000 seconds, while the phase noise requirement is < -50 dBc/Hz for a 1 Hz offset. Various design techniques have been used for the DSN radio frequency (RF) electronics, high power transmitters and antenna structures to meet the stringent requirements for all 3 of these parameters. Some details for the design techniques will be described in the paper. Another important consideration for a radio science system is the verification approach for components, as well as for individual subsystems and then the overall system. Phase-locked oscillators (PLOs) are one of the key component types that determine overall phase noise and Allen deviation system performance. Measurement techniques used for PLOs, as well as for the overall ground system, will be discussed. Measurement results for the 2 new DSN antennas, recently built under the DSN Aperture Enhancement Project (DAEP) will also be shown. In addition, some recent radio science measurements from the Cassini and JUNO missions, using the new antennas, will be presented.

LaBelle, Remi C.↗

Ultralow-temperature cryogenic transmission electron microscopy using a new helium flow cryostat stage

Advances in cryogenic electron microscopy have opened new avenues for probing quantum phenomena in correlated materials. This study reports the installation and performance of a new side-entry condenZero cryogenic cooling system for JEOL (Scanning) Transmission Electron Microscopes (S/TEM), utilizing compressed liquid helium (LHe) and designed for imaging and spectroscopy at ultra-low temperatures. The system includes an external dewar mounted on a vibration-damping stage and a pressurized, low-noise helium transfer line with a remotely controllable needle valve, ensuring stable and efficient LHe flow with minimal thermal and mechanical noise. Performance evaluation demonstrates a stable base temperature of 4.37 K measured using a Cernox bare chip sensor on the holder with temperature fluctuations within ±0.004 K. Complementary in-situ electron energy-loss spectroscopy (EELS) via aluminum bulk plasmon analysis was used to measure the local specimen temperature and validate cryogenic operation during experiments. The integration of cryogenic cooling with other microscopy techniques, including electron diffraction and Lorentz TEM, was demonstrated by resolving charge density wave (CDW) transitions in NbSe2 using electron diffraction, and imaging nanometric magnetic skyrmions in MnSi via Lorentz TEM. In conclusion, this platform provides reliable cryogenic operation below 7 K, establishing a low-drift route for direct visualization of electronic and magnetic phase transformations in quantum materials.

Charge density wave↗

Characterization and Automation of Quantum Electronics for Qubit-based Dark Matter Detector

The hypothetical axion particle is not only a potential solution to the strong CP problem of quantum chromodynamics but also is a compelling cold dark matter candidate. Searching for axions requires sensitivity that is achievable only with superconducting qubits and other quantum-noise limited devices. This work focuses on the characterization of one such device, a Traveling Wave Parametric Amplifier (TWPA). This was accomplished through developing techniques for remote control and operation of various electronics and the TWPA used in qubit-based dark matter searches.

Zaidel, Michael↗

Exploring electron-beam induced modifications of materials with machine-learning assisted high temporal resolution electron microscopy

Directed atomic fabrication using an aberration-corrected scanning transmission electron microscope (STEM) opens new pathways for atomic engineering of functional materials. In this approach, the electron beam is used to actively alter the atomic structure through electron beam induced irradiation processes. One of the impediments that has limited widespread use thus far has been the ability to understand the fundamental mechanisms of atomic transformation pathways at high spatiotemporal resolution. Here, we develop a workflow for obtaining and analyzing high-speed spiral scan STEM data, up to 100 fps, to track the atomic fabrication process during nanopore milling in monolayer MoS 2 . An automated feedback-controlled electron beam positioning system combined with deep convolution neural network (DCNN) was used to decipher fast but low signal-to-noise datasets and classify time-resolved atom positions and nature of their evolving atomic defect configurations. Through this automated decoding, the initial atomic disordering and reordering processes leading to nanopore formation was able to be studied across various timescales. Using these experimental workflows a greater degree of speed and information can be extracted from small datasets without compromising spatial resolution. This approach can be adapted to other 2D materials systems to gain further insights into the defect formation necessary to inform future automated fabrication techniques utilizing the STEM electron beam.

36 MATERIALS SCIENCE↗

Charge-coupled device (CCD) television camera for NASA's Galileo mission to Jupiter

The CCD detector under construction for use in the slow-scan television camera for the NASA Galileo Jupiter orbiter to be launched in 1985 is presented. The science objectives and the design constraints imposed by the earth telemetry link, platform residual motion, and the Jovian radiation environment are discussed. Camera optics are inherited from Voyager; filter wavelengths are chosen to enable discrimination of Galilean-satellite surface chemical composition. The CCO design, an 800 by 800-element 'virtual-phase' solid-state silicon image-sensor array with supporting electronics, is described with detailed discussion of the thermally generated dark current, quantum efficiency, signal-to-noise ratio, and resolution. Tests of the effect of ionizing radiation were performed and are analyzed statistically. An imaging mode using a 2-1/3-sec frame time and on-chip summation of the signal in 2 x 2 blocks of adjacent pixels is designed to limit the effects of the most extreme Jovian radiation. Smearing due to spacecraft/target relative velocity and platform instability will be corrected for via an algorithm maximizing spacial resolution at a given signal-to-noise level. The camera is expected to produce 40,000 images of Jupiter and its satellites during the 20-month mission.

Klaasen, K. P.↗

Microchannel intensified electrography

Although electrography is an attractive electronic imaging technique, it suffers at low light levels from limitations imposed by microphotometer and emulsion grain noise. The use of microchannel intensification allows individual photoelectron events to be unambiguously detected and measured, with little loss of achievable resolution. A series of quantitative studies have been conducted to determine the gains in detectivity and SNR yielded by the use of this technique, through microphotometry and computer analysis of images identical or similar to laboratory light sources, by means of both unintensified and microchannel-intensified electromagnetic Schmidt cameras. Applications of the technique to far-UV wide field imaging and nebular spectrograph experiments are described.

Heckathorn, H. M.↗

Energy-Based Tetrahedron Sensor for High-Temperature, High-Pressure Environments

An acoustic energy-based probe has been developed that incorporates multiple acoustic sensing elements in order to obtain the acoustic pressure and three-dimensional acoustic particle velocity. With these quantities, the user can obtain various energy-based quantities, including acoustic energy density, acoustic intensity, and acoustic impedance. In this specific development, the probe has been designed to operate in an environment characterized by high temperatures and high pressures as is found in the close vicinity of rocket plumes. Given these capabilities, the probe is designed to be used to investigate the acoustic conditions within the plume of a rocket engine or jet engine to facilitate greater understanding of the noise generation mechanisms in those plumes. The probe features sensors mounted inside a solid sphere. The associated electronics for the probe are contained within the sphere and the associated handle for the probe. More importantly, the design of the probe has desirable properties that reduce the bias errors associated with determining the acoustic pressure and velocity using finite sum and difference techniques. The diameter of the probe dictates the lower and upper operating frequencies for the probe, where accurate measurements can be acquired. The current probe design implements a sphere diameter of 1 in. (2.5 cm), which limits the upper operating frequency to about 4.5 kHz. The sensors are operational up to much higher frequencies, and could be used to acquire pressure data at higher frequencies, but the energy-based measurements are limited to that upper frequency. Larger or smaller spherical probes could be designed to go to lower or higher frequency range

Gee, Kent L.↗

On the generation of broadband electrostatic noise

Linear theory analysis and particle simulation studies were carried out to understand the mechanisms generating broadband electrostatic noise (BEN) and the effects of BEN on particles as well as the nonlinear saturation level in the geomagnetic tail region. Streaming ion beams as well as warm ions and electrons are used to model the plasma-sheet particle population. When the beam ion temperature is comparable to the temperature of the warm plasma-sheet particles, electrostatic ion cyclotron instabilities become unstable, giving rise to low-frequency noise at omega less than about n(Omega i), where Omega i is the ion gyrofrequency.

Ashour-Abdalla, M.↗

Magnetic flux noise in superconducting qubits and the gap states continuum

In the present study we investigate the selected local aspects of the metal-induced gap states (MIGSs) at the disordered metal–insulator interface, that were previously proposed to produce magnetic moments responsible for the magnetic flux noise in some of the superconducting qubit modalities. Our analysis attempts to supplement the available studies and provide new theoretical contribution toward their validation. In particular, we explicitly discuss the behavior of the MIGSs in the momentum space as a function of the onsite energy deviation, that mimics random potential disorder at the interface in the local approximation. It is found, that when the difference between the characteristic electronic potentials in the insulator increases, the corresponding MIGSs become more localized. This effect is associated with the increasing degree of the potential disorder that was earlier observed to produce highly localized MIGSs in the superconducting qubits. At the same time, the presented findings show that the disorder-induced localization of the MIGSs can be related directly to the decay characteristics of these states as well as to the bulk electronic properties of the insulator. As a result, our study reinforces plausibility of the previous corresponding investigations on the origin of the flux noise, but also allows to draw future directions toward their better verification.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Skipper-CCD Output Sensitivity Improvement with a Common Source Cascode Amplifier

A Skipper-CCD output has been traditionally readout in a source follower configuration, also known as common drain, mainly because in this configuration a good compromise between sensitivity, noise and speed is achieved. In this work a different approach is presented: the output transistor is connected in a common source configuration and an external cascode device is added in series, obtaining a voltage gain higher than unity without increasing significantly the parasitic capacitance due to Miller effect and thus increasing the obtained voltage per electron of charge. The proposed output stage improves the sensitivity 3.4 times when compared with the traditionally used stage while keeping almost the same equivalent noise charge.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Deep Learning Enabled Strain Mapping of Single-Atom Defects in Two-Dimensional Transition Metal Dichalcogenides with Sub-Picometer Precision

Two-dimensional (2D) materials offer an ideal platform to study the strain fields induced by individual atomic defects, yet challenges associated with radiation damage have so far limited electron microscopy methods to probe these atomic-scale strain fields. In this work, we demonstrate an approach to probe single-atom defects with sub-picometer precision in a monolayer 2D transition metal dichalcogenide, WSe 2–2x Te 2x . We utilize deep learning to mine large data sets of aberration-corrected scanning transmission electron microscopy images to locate and classify point defects. By combining hundreds of images of nominally identical defects, we generate high signal-to-noise class averages which allow us to measure 2D atomic spacings with up to 0.2 pm precision. Our methods reveal that Se vacancies introduce complex, oscillating strain fields in the WSe 2–2x Te 2x lattice that correspond to alternating rings of lattice expansion and contraction. These results indicate the potential impact of computer vision for the development of high-precision electron microscopy methods for beam-sensitive materials.

2D materials↗

A novel integrated time-resolved array avalanche photodiode detection system for nuclear resonant scattering measurements

Here, the nuclear resonant scattering (NRS) experiment requires photon-counting detectors with high time resolution, short dead time, large dynamic range, low noise, and large detection area. An 8-channel avalanche photodiode (APD) array detector system with high integrity, flexibility, and reliability has been developed to adapt to the demands of NRS experiments. The detector system mainly consists of four key parts: (i) an array-APD sensor, (ii) 8-channel integrated fast preamplifiers, (iii) the time-to-digital converter readout electronics, and (iv) a data acquisition system and EPICS support software. Remarkably, the system exhibits a time resolution of better than 500 ps and has a sufficiently low noise level, allowing for the lowest detection energy threshold of 4 keV. The performance of the new array-APD system as well as its real application in nuclear forward scattering (NFS) and nuclear resonant inelastic x-ray scattering (NRIXS) experiments was tested in two synchrotron facilities. With the new system, the NFS signal very close to the prompt electronic scattering signal can be extracted. Thanks to the customized EPICS-areaDetector-based control software, NRIXS spectra can be readily measured with time and energy information of the NRIXS signal stored in the raw data, which is promising for developing NRIXS data analysis in the time domain. The array-APD detector can be deployed for nuclear resonant scattering experiments at various synchrotron radiation facilities.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Magnetoresistance and noise properties of chevron stretcher detectors for field access bubble domain devices

Experiments were devised to study the angular variation of the resistance and noise properties of one- and two-level chevron stretcher magnetoresistive detectors for use in field access bubble memory devices. All measurements, made with an electronic system, were performed on glass or garnet samples upon which 1 micron of SiO2 was sputter-deposited, followed by 4000 A of Permalloy for the 28-micron-period devices and 0.8 microns of SiO2, followed by 3000 A of Permalloy for the 20-micron-period devices. The geometrical and drive-state dependence of the zero-state noise were studied, as was its frequency dependence. It is found that both types of detectors operate primarily in the amplitude-shift mode for drive fields of interest and that the presence of a bubble in a detector causes a magnetoresistance change equal to that produced by increasing the in-plane drive field about 8 Oe in the absence of a bubble.

George, P. K.↗

Revealing local order via high energy EELS

Short range order (SRO) is critical in determining the performance of many important engineering materials. However, accurate characterization of SRO with high spatial resolution – which is needed for the study of individual nanoparticles and at material defects and interfaces – is often experimentally inaccessible. Here, we locally quantify SRO via scanning transmission electron microscopy with extended energy loss fine structure analysis. Specifically, we use novel instrumentation to perform electron energy loss spectroscopy out to 12 keV, accessing energies which are conventionally only possible using a synchrotron. Our data is of sufficient energy resolution and signal-to-noise ratio to perform quantitative extended fine structure analysis, which allows determination of local coordination environments. To showcase this technique, we investigate a multicomponent metallic glass nanolaminate and locally quantify the SRO with <10 nm spatial resolution; this measurement would have been impossible with conventional synchrotron or electron microscopy methods. Finally, we discuss the nature of SRO within the metallic glass phase, as well as the wider applicability of our approach for determining processing–SRO–property relationships in complex materials.

36 MATERIALS SCIENCE↗