Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “electron detectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 865 records · Page 48

Highly excited electron cyclotron for QCD axion and dark-photon detection

We propose using highly excited cyclotron states of a trapped electron to detect meV axion and dark-photon dark matter, marking a significant improvement over our previous proposal and demonstration [One-electron quantum cyclotron as a milli-ev dark-photon detector, .]. When the axion mass matches the cyclotron frequency ω c , the cyclotron state is resonantly excited, with a transition probability proportional to its initial quantum number, n c . The sensitivity is enhanced by taking n c ∼ 10 6 ( 0.1 meV ω c ) 2 . By optimizing key experimental parameters, we minimize the required averaging time for cyclotron detection to t ave ∼ 10 − 6 s, permitting detection of such a highly excited state before its decay. An open–end-cap trap design enables the external photon signal to be directed into the trap, rendering our background-free detector compatible with large focusing cavities, such as the BREAD proposal, while capitalizing on their strong magnetic fields. Furthermore, the axion conversion rate can be coherently enhanced by incorporating layers of dielectrics with alternating refractive indices within the cavity. Collectively, these optimizations enable us to probe the QCD axion parameter space from 0.1 to 2.3 meV (25–560 GHz), covering a substantial portion of the predicted postinflationary QCD axion mass range. This sensitivity corresponds to probing the kinetic mixing parameter of the dark photon down to ε ≈ 2 × 10 − 16 . Published by the American Physical Society 2025

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

First Measurement of Deeply Virtual Compton Scattering on the Neutron with Detection of the Active Neutron

Measuring deeply virtual Compton scattering (DVCS) on the neutron is one of the necessary steps to understand the structure of the nucleon in terms of generalized parton distributions (GPDs). Neutron targets play a complementary role to transversely polarized proton targets in the determination of the GPD E . This poorly known and poorly constrained GPD is essential to obtain the contribution of the quarks’ angular momentum to the spin of the nucleon. DVCS on the neutron was measured for the first time selecting the exclusive final state by detecting the neutron, using the Jefferson Lab longitudinally polarized electron beam, with energies up to 10.6 GeV, and the CLAS12 detector. The extracted beam-spin asymmetries, combined with DVCS observables measured on the proton, allow a clean quark-flavor separation of the imaginary parts of the Compton form factors H and E . Published by the American Physical Society 2024

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Erratum: Centrality-Dependent Modification of Jet-Production Rates in Deuteron-Gold Collisions at $\sqrt{𝑠_{𝑁⁢𝑁}}$ = 200 GeV [Phys. Rev. Lett. 116, 122301 (2016)]

We previously reported jet-production rates in 𝑝 + 𝑝 and 𝑑 + Au collisions at $\sqrt{𝑠_{𝑁⁢𝑁}}$ = 200 GeV recorded in 2008 with the PHENIX detector at the Relativistic Heavy Ion Collider. Subsequently, we found that electronic noise in the electromagnetic calorimeter was not completely removed by the tower-timing cuts used in the analysis. We have conducted an independent re-analysis of the data that eliminated noisy towers by removing them completely from the analysis. These cuts remove any contributions from instrumental noise, but reduce the overall acceptance for electromagnetic clusters by ≈16% and hence the overall statistical power of the data. Finally, this re-analysis found that instrumental noise in the electromagnetic calorimeter led to an artificial increase in the jet yield for both the 𝑝 + 𝑝 and 𝑑 + Au collisions.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Design of MARCO, the New Solenoidal Detector Magnet for the ePIC Experiment at BNL

MARCO is the new superconducting solenoid for ePIC, the general-purpose detector capable of delivering the full scientific scope of the Electron-Ion Collider at Brookhaven National Laboratory. Here, this 3.84 m long solenoid, with a bore diameter of 2.84 m, will provide a magnetic field of 2.0 T at the center with a nominal current of 4 kA at 4.5 K, for a total stored energy of 45 MJ. Its conductor is a NbTi Rutherford in Copper Channel (RICC), specially designed to stand the high mechanical loads induced by the magnetic field. Its copper stabilizer will assure the protection in case of quench. The coils are wound into six layers inside a thin external mandrel in brass, with a triple role of mechanical reinforcement, cryogenic support for the thermosiphon circuit and quench-back propagator. With a cold mass average radial thickness of just 7 cm, the magnet fulfills all the criterions of transparency for the particles directed to the hadronic calorimeter forecast around the cryostat. In this paper, the design of MARCO is presented, with a specific focus on the magnetic and quench analysis.

Calvelli, Valerio [Commissariat a l'Energie Atomiq↗

Radiation Transport Simulation of the Sulfur Counting System in the Radiation Metrology Laboratory (RML)

At the request of staff members from the Radiation Metrology Laboratory (RML), a series of Monte Carlo radiation transport calculations were performed using two different models of the detector geometry of the RMLs sulfur counting system. The fraction of electrons from each β-decay of 32 P in the sulfur pellet that enter the window of the sulfur counting system was calculated with both MCNP and ITS. In addition, the differential energy distributions of the electrons entering the counting system window were computed. There was significant agreement between the integral and differential quantities calculated by the two transport codes. Summary tables are for the integral efficiency values are found in the body of the report.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Neutrino Oscillation Results from the NOvA Experiment

The NOvA experiment is a long-baseline accelerator-based neutrino oscillation experiment that uses the upgraded NuMI beam from Fermilab to measure electron-neutrino appearance and muon-neutrino disappearance between the Near Detector, located at Fermilab, and the Far Detector, located at Ash River, Minnesota. NOvA's primary physics goals include precision measurements of oscillation parameters, such as $\theta_{23}$ and the atmospheric mass-squared splitting, along with probes of the mass hierarchy and of the CP-violating phase. This talk will cover NOvA’s most recent three-flavor oscillation results, based on a neutrino beam exposure of 13.6E20 protons-on-target and an anti-neutrino beam exposure of 12.5E20 protons-on-target.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The DUNE Vertical Drift Photon Detection System

The Deep Underground Neutrino Experiment (DUNE) is a long-baseline neutrino experiment designed to mainly investigate oscillation parameters, supernova physics and proton decay. Its far detector will be composed of four liquid argon time projection chamber (LArTPC) underground modules, in South Dakota-USA, which will detect a neutrino beam produced at Fermilab, 1300 km away, where a near detector will be in place. The second DUNE far detector module, Vertical Drift, will be a single phase LArTPC with electron drift along the vertical axis with two volumes of 13.5 m x 6.5 m x 60 m dimensions separated by a cathode plane. The charge collection will be performed by two anode planes placed at the top and bottom of the module, each composed by stacked layers of a perforated PCB technology with electrode strips. The photon detection system (PDS) will make use of large size X-Arapuca tiles distributed over three detection planes. One plane will consist of a horizontal arrangement of double sided tiles installed on the high voltage cathode plane and two vertical planes, each placed on the longest cryostat membrane walls. A light active coverage of 14.8% over the cathode and 7.4% over the laterals should allow improvements in the low energy physics range that can be probed in DUNE, especially regarding supernova neutrinos (~10 MeV). We present the initial characterization of the Vertical Drift PDS using a Monte Carlo simulation and preliminary studies on its reconstruction capabilities at the MeV scale. The information obtained with the PDS alone should allow determination of a neutrino interaction region with a precision of at least 65 cm for events with deposited energy above 5 MeV and the deposited energy can be reconstructed with precision better than 10%, both at the center of the volume.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measuring the Beam-Spin Asymmetry of Hard Exclusive ¿0 Production off the Neutron with CLAS12

Over the course of the last couple of decades, Generalised Parton Distributions (GPDs) have become a compelling area of focus in both theoretical and experimental research in the ?eld of hadronic structure. GPDs can be indirectly accessed via observables in hard exclusive reactions such as Deeply Virtual Compton Scattering (DVCS) and Deeply Virtual Meson Production (DVMP). In these reactions, an incident lepton scatters o? an individual quark within the target nucleon via the exchange of a virtual photon, and a real photon (DVCS) or a meson (DVMP) are emitted as a result. This thesis presents an analysis of Deeply Virtual ?0 Meson Production o? the neutron in the deuteron (nDV?0P). The data were taken with the CLAS12 detector, which is housed in the experimental Hall B at the Je?erson National Laboratory (JLab) in Virginia, USA. A longitudinally polarised electron beam delivered by JLab?s Continuous Electron Beam accelerator Facility (CEBAF), at an energy of 10.2 and 10.6 GeV, was incident on a liquid deuterium target housed within the CLAS12 detector assembly. The nDV?0P channel is sensitive to the lesser-studied chiral-odd transversity GPDs. GPDs are accessed indirectly via observables related to the cross-sections of hard exclusive processes. One such example is the beam-spin asymmetry (?LU) as a function of Trento-?, the angle between the leptonic plane and the hadronic plane which are de?ned with the beam and scattered electron, and with the recoiling neutron and reconstructed ?0, respectively. Despite the limited statistics, the observable ?LU was successfully extracted for eight kinematic bins (four in Mandelstam ?, and two in ??). This is a ?rst measurement for nDV?0P in the phase-space which is now available with CLAS12 in the 12 GeV era of JLab.

Naidoo, Paul↗

Using cyclotron radiation emission for ultra-high resolution x-ray spectroscopy

Abstract Cyclotron radiation emission spectroscopy (CRES) is an approach to measuring the energy of an electron trapped in an externally applied magnetic field. The bare electron can come from different interactions, including photoelectric absorption, Compton scatters, beta decay, and pair production. CRES relies on measuring the frequency of the electron’s cyclotron motion, and because the measurement times extend over 10 6 –10 7 cycles, the energy resolution is on the order of a single electronvolt. To date, CRES has only been performed on internal beta-emitting radioisotopes, but the technology can be applied to x-ray spectrometery through appropriate selection of a target gas and sufficient intensity of the distinct x-ray source. The applications of this technology range from high-precision measurements of atomic energy levels to calibrations of basic science experiments, to trace element identification. In this work we explore the use of CRES for x-ray spectroscopy within the rubric of measuring the energy levels of argon. Though the energy levels of argon are well established, we adopt this motivation as an example question around which a detector may be designed. The issues we explore include target material, density, electron trapping depth, noise levels, and overall efficiency. We also discuss spectral deconvolution and how the multiple peaks obtained from a single target/source pair can be used to enhance the robustness of the measurement.

07 ISOTOPE AND RADIATION SOURCES↗

Search for new phenomena in events with two opposite-charge leptons, jets and missing transverse momentum in pp collisions at $ \sqrt{\mathrm{s}} $ = 13 TeV with the ATLAS detector

The results of a search for direct pair production of top squarks and for dark matter in events with two opposite-charge leptons (electrons or muons), jets and missing transverse momentum are reported, using 139 fb –1 of integrated luminosity from proton-proton collisions at √s = 13 TeV, collected by the ATLAS detector at the Large Hadron Collider during Run 2 (2015–2018). This search considers the pair production of top squarks and is sensitive across a wide range of mass differences between the top squark and the lightest neutralino. Additionally, spin-0 mediator dark-matter models are considered, in which the mediator is produced in association with a pair of top quarks. The mediator subsequently decays to a pair of dark-matter particles. No significant excess of events is observed above the Standard Model background, and limits are set at 95% confidence level. The results exclude top squark masses up to about 1 TeV, and masses of the lightest neutralino up to about 500 GeV. Limits on dark-matter production are set for scalar (pseudoscalar) mediator masses up to about 250 (300) GeV.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Ultra low background time projection alpha particle detector ( Phase II Final Scientific/Technical Report)

When alpha particles are emitted into a gas they create an ionization track of gas ions and electrons. In our commercial UltraLo instrument we apply a voltage between a planar sample and an anode, integrate the anode signal as it collects the electrons, and distinguish between alphas emitted from the sample and elsewhere (anode, sidewalls) by the duration and shape of the resultant signal. The major contributors limiting the instrument’s lower detection limit are cosmic rays that pass through the detector close to the sample and Rn decays that produce charge tracks the originate in the gas and end on the sample. In this work we proposed to identify and reject these events by converting the anode into a multi-pixel array and operating in time projection mode. Cosmic rays would be eliminated by generating charge on many pixels, while charge collection asymmetry would distinguish between sample events (Bragg curve up) and Rn events (Bragg curve down). We therefore proposed to modify an UltraLo by pixilating its anode, developing low noise, low power multiplexed electronics to track each pixel’s signal individually, and develop analysis software to make the required discriminations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Prospects for measuring the time variation of astrophysical neutrino sources at dark matter detectors

We study the prospects for measuring the time variation of solar and atmospheric neutrino fluxes at future large-scale xenon and argon dark matter detectors. For solar neutrinos, a yearly time variation arises from the eccentricity of Earth’s orbit and, for charged current interactions, from a smaller energy-dependent day-night variation due to flavor regeneration as neutrinos travel through Earth. For a 100-ton xenon detector running for ten years with a xenon-136 fraction of ≲ 0.1 % , in the electron recoil channel a time-variation amplitude of about 0.8% is detectable with a power of 90% and the level of significance of 10%. This is sufficient to detect time variation due to eccentricity, which has amplitude of ∼ 3 % . In the nuclear recoil channel, the detectable amplitude is about 10% under current detector resolution and efficiency conditions, and this generally reduces to about 1% for improved detector resolution and efficiency, the latter of which is sufficient to detect time variation due to eccentricity. Our analysis assumes both known and unknown periods. We provide scalings to determine the sensitivity to an arbitrary time-varying amplitude as a function of detector parameters. Identifying the time variation of the neutrino fluxes will be important for distinguishing neutrinos from dark matter signals and other detector-related backgrounds and extracting properties of neutrinos that can be uniquely studied in dark matter experiments. Published by the American Physical Society 2024

Zhuang, Yi (ORCID:0000000277138724)↗

Magnetic-Field Diffusion Effects in Beam Position Monitors I: Theory

Beam position monitors (BPMs) provide time-resolved measurements of the current and centroid position of high-current electron beams in linear induction accelerators (LIAs). One of the types of detectors used in BPMs is the B-dot loop, which generates a signal from the EMF due to the time varying magnetic flux through the loop. If some of the boundaries of the loop are composed of thick metal walls with finite conductivity, the resulting signal must be corrected for the magnetic field diffusion into the metal. The theoretically predicted flux due to diffusion is in remarkable agreement with experimental measurements

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Mu2e straw tracker detector status and prototype results

The Mu2e experiment will search for charge-lepton flavor violating (CLFV) muon to electron conversion. It aims to achieve a four-orders of magnitude improvement in sensitivity over previous experiments, allowing it to probe new physics at mass scales up to 10 4 TeV . A precision momentum measurement is needed to resolve the monoenergetic electron that is the signal of CLFV conversion from muon decay-in-orbit backgrounds. Here, this is achieved in Mu2e using a low-mass cylindrical straw tracker operated in vacuum, consisting of 21,000 thin-wall mylar straws held at tension. The Mu2e tracker is now in production and will be completed during 2025. We will discuss the design and status of the experiment and the tracker detector, and show results from data taken with the first tracker module.

Gaseous detector↗

Monolayer Semiconductor Auger Detector

Auger recombination in semiconductors is a many-body phenomenon in which the recombination of electrons and holes is accompanied by excitation of other charge carriers. The excess energy of the excited carriers is normally rapidly converted to heat, making Auger processes difficult to probe directly. In this paper, we employ a technique in which the Auger-excited carriers are detected by their ability to tunnel out of the semiconductor through a thin barrier, generating a current. We use vertical van der Waals heterostructures with monolayer WSe 2 as the semiconductor, with hexagonal boron nitride as the tunnel barrier, and a graphite collector electrode. The Auger processes combined with resonant absorption produce characteristic negative photoconductance. We detect holes Auger-excited by both neutral and charged excitons and find that the Auger scattering is surprisingly strong under weak excitation. Our work expands the range of techniques available for probing relaxation processes in 2D materials.

47 OTHER INSTRUMENTATION↗

Search for Beyond the Standard Model physics with anomaly detection in multilepton final states in pp collisions at s=13TeV with the ATLAS detector

A model-agnostic search for Beyond the Standard Model physics is presented, targeting final states with at least four light leptons (electrons or muons). The search regions are separated by event topology and unsupervised machine learning is used to identify anomalous events in the full 140 fb-1$$^{-1}$$ of proton–proton collision data collected with the ATLAS detector during Run 2. No significant excess above the Standard Model background expectation is observed. Model-agnostic limits are presented in each topology, along with limits on several benchmark models including vector-like leptons, wino-like charginos and neutralinos, or smuons. Limits are set on the flavourful vector-like lepton model for the first time.

Aad, G↗

Time-Resolved Beam Position Measurements for the Scorpius Multipulse Linear Induction Accelerator

Beam position monitors (BPMs) provide time-resolved measurements of the current and centroid position of high-current electron beams in linear induction accelerators (LIAs). One of the types of detectors used in BPMs is the B-dot loop, which generates a signal from the EMF due to the time varying magnetic flux through the loop. If some of the boundaries of the loop are composed of thick metal walls with finite conductivity, the resulting signal must be corrected for the magnetic field diffusion into the metal. The theoretically predicted flux due to diffusion is in remarkable agreement with experimental measurements. Although accurate BPM measurements of beam current require correction of magnetic field diffusion, accurate measurement of beam position requires no correction. In this note, we present a theoretical derivation and the experimental validation of this result.

43 PARTICLE ACCELERATORS↗

Laser calibration system at ProtoDUNE-HD

The Deep Underground Neutrino Experiment (DUNE) is a full experiment consisting of multiple detectors separated by a near and far site. DUNE will study long-baseline neutrino oscillations, which will provide insight into CP-violation, neutrino mass ordering, and the matter/antimatter asymmetry. Additionally, DUNE will search for nucleon decay and observe neutrinos from supernovae. DUNE relies on liquid argon time projection chambers (LAr TPCs), an excellent technology for tracking particles and reconstructing their interactions with high precision. To achieve its goals, DUNE is supported by the ProtoDUNE experiments at CERN, which serve as large-scale prototypes to validate detector technologies and calibration systems. The precise calibration of the electric field within the detector is vital for accurate 3D reconstruction of particle tracks, particularly in maintaining the consistency of charge measurements along the drift path. This work presents the development and implementation of a laser calibration system designed for ProtoDUNE-II. This poster involved the physical installation and commissioning of the laser system. The commissioning process included extensive testing to ensure alignment and operational efficiency, such as rotating the laser to observe behavior of tracks. The groundwork established during these steps is crucial for future data analysis, aiming to measure the electron lifetime (in the active volume) and map the electric field inside the detector with high precision.