Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “electron beam accelerators”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 865 records · Page 48

Beam loading in a laser-plasma accelerator using a near-hollow plasma channel

Beam loading in laser-plasma accelerators using a near-hollow plasma channel is examined in the linear wake regime. It is shown that, by properly shaping and phasing the witness particle beam, high-gradient acceleration can be achieved with high-efficiency, and without induced energy spread or emittance growth. Both electron and positron beams can be accelerated in this plasma channel geometry. Matched propagation of electron beams can be achieved by the focusing force provided by the channel density. For positron beams, matched propagation can be achieved in a hollow plasma channel with external focusing. The efficiency of energy transfer from the wake to a witness beam is calculated for single ultra-short bunches and bunch trains.

43 PARTICLE ACCELERATORS↗

Role of the laser pulse-length in producing high-quality electron beams in a homogenous plasma

In laser wakefield acceleration, the pulse-length of the laser is an important parameter that affects the laser evolution and electron beam injection and acceleration in the bubble regime. Here, we use three-dimensional simulations to find, for a given plasma density, the optimal pulse-length that gives the best quality electron beam. For three different pulse lengths, we study the evolution dynamics of the laser spot-size and quality of the injected electron beam. We find that a pulse-length that is less than the theoretical optimum, {tau}{sub L} = {lambda}{sub p}/{radical}2{pi}c, derived from linear theory, gives the best beam quality. Conversely, our simulations suggest that for a given laser system, with a fixed pulse-length, there is an optimal value of the plasma density that will give the best quality accelerated beams in experiments. For an rms pulse-length of 10 fs (around 24 fs FWHM), this corresponds to a plasma density of around 3.4 Multiplication-Sign 10{sup 18}/cm{sup 3}. For these parameters, we obtain, in a homogenous plasma and with a single laser, an electron beam with an energy of around 700 MeV, an energy-spread less than 2%, and rms normalized emittance of a few {pi} mm-mrad.

43 PARTICLE ACCELERATORS↗

Preliminary Activation Analysis of Accelerator Components and Beam Stops at the NSLS-II

Bremsstrahlung is generated at the accelerator systems of the synchrotron radiation facilities by the radiative interaction of circulating electron beam with the accelerator components and with the residual gas molecules in the vacuum chamber. The photoneutron interaction of bremsstrahlung with the materials leads to the radio activation of the accelerator components through neutron emission and the production of radioisotopes. However this activation interaction is a second order effect because the intermediate process of bremsstrahlung production is involved. The photoneutron interaction takes place above the threshold bremsstrahlung energy of 7-20 MeV and the cross section for these interactions are in millibarns.

36 MATERIALS SCIENCE↗

Formation of electron bunches with tailored current profiles using multi-frequency linacs

Tailoring an electron bunch with specific current profile can provide substantial enhancement of the transformer ratio in beam-driven acceleration methods. We present a method relying on the use of a linac with accelerating sections operating at different frequencies followed by a magnetic bunch compressor. The experimental verfification of the technique in a two-frequency linac is presented. The compatibility of the proposed technique with the formation and acceleration of a drive and witness bunches is numerically demonstrated.

43 PARTICLE ACCELERATORS↗

Characterization of a synthetic single crystal diamond Schottky diode for radiotherapy electron beam dosimetry

Purpose: To investigate the dosimetric properties of synthetic single crystal diamond based Schottky diodes under irradiation with therapeutic electron beams from linear accelerators. Methods: A single crystal diamond detector was fabricated and tested under 6, 8, 10, 12, and 15 MeV electron beams. The detector performances were evaluated using three types of commercial detectors as reference dosimeters: an Advanced Markus plane parallel ionization chamber, a Semiflex cylindrical ionization chamber, and a p-type silicon detector. Preirradiation, linearity with dose, dose rate dependence, output factors, lateral field profiles, and percentage depth dose profiles were investigated and discussed. Results: During preirradiation the diamond detector signal shows a weak decrease within 0.7% with respect to the plateau value and a final signal stability of 0.1% (1{sigma}) is observed after about 5 Gy. A good linear behavior of the detector response as a function of the delivered dose is observed with deviations below {+-}0.3% in the dose range from 0.02 to 10 Gy. In addition, the detector response is dose rate independent, with deviations below 0.3% in the investigated dose rate range from 0.17 to 5.45 Gy/min. Percentage depth dose curves obtained from the diamond detector are in good agreement with the ones from the reference dosimeters. Lateral beam profile measurements show an overall good agreement among detectors, taking into account their respective geometrical features. The spatial resolution of solid state detectors is confirmed to be better than that of ionization chambers, being the one from the diamond detector comparable to that of the silicon diode. A good agreement within experimental uncertainties was also found in terms of output factor measurements between the diamond detector and reference dosimeters. Conclusions: The observed dosimetric properties indicate that the tested diamond detector is a suitable candidate for clinical electron beam dosimetry.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Worldwide Overview of Plasma Wakefield Accelerator Experiments

We briefly review the status of plasma wakefield accelerator (PWFA) experiments. We attempt to identify the most important experimental issues that will have to be addressed to strengthen the case of a future PWFA-based electron/positron linear collider. We describe PWFA experiments that are either running, under construction or that will be proposed in the near future.

43 PARTICLE ACCELERATORS↗

Beam Transport Testing for the Production Accelerator Arrangement

The beam transport system is designed to deliver an electron beam from the accelerator to the target. The design of the beam line depends on beam parameter (energy, energy spread, etc.) and target geometry. Elements of the beam transport system should provide transportation, focusing, and positioning of the beam onto the target surface.

43 PARTICLE ACCELERATORS↗

Activation Analysis of Soil, Air and Water near the NSLS-II Accelerator Enclosures

The radiation environment in the accelerator enclosures is sufficiently high energy to permit the activation of air inside the accelerator enclosures, soil surrounding the concrete shielding of the enclosures and the coolant water used for cooling various components of the accelerator system like magnets etc. Bremsstrahlung is generated inside the accelerator enclosures by the radiative interaction of the electron beam with the accelerator components.

36 MATERIALS SCIENCE↗

Synchronous acceleration with tapered dielectric-lined waveguides

Here, we present a general concept to accelerate non-relativistic charged particles. Our concept employs an adiabatically-tapered dielectric-lined waveguide which supports accelerating phase velocities for synchronous acceleration. We propose an ansatz for the transient field equations, show it satisfies Maxwell's equations under an adiabatic approximation and find excellent agreement with a finite-difference time-domain computer simulation. The fields were implemented into the particle-tracking program {\sc astra} and we present beam dynamics results for an accelerating field with a 1-mm-wavelength and peak electric field of 100~MV/m. The numerical simulations indicate that a $\sim 200$-keV electron beam can be accelerated to an energy of $\sim10$~MeV over $\sim 10$~cm. The novel scheme is also found to form electron beams with parameters of interest to a wide range of applications including, e.g., future advanced accelerators, and ultra-fast electron diffraction.

43 PARTICLE ACCELERATORS↗

Observations of waves artificially stimulated by an electron beam inside a region with auroral precipitation

Observations of waves stimulated by artificial injection inside an auroral arc by an electron accelerator mounted on the POLAR 5 sounding rocket are presented. The accelerator produced a pulsed electron beam with currents up to 130 mA and energies up to 10 keV; emissions after the end of beam injection were generated by perturbations in the ambient plasma near the accelerator during beam injection. These emissions were independent of the electron beam direction along the geomagnetic field. The high frequency emission observed after beam injection correlated with the passage through an auroral arc; the low frequency emissions after beam injection were concentrated in two bands below the lower hybrid frequency.

Grandal, B.↗

A compact electron source for the dielectric laser accelerator

In this work, we design and demonstrate a compact electron source that combines an integrated silicon nanotip photoemitter with a compact silicon-based electrostatic lens. The lens simultaneously accelerates electrons to 30 keV and focuses the resulting beam to a 0.4 μm (RMS) beam diameter with 62 pm-rad normalized emittance at a distance of 20 mm from the cathode. The compact nature of this lens provides a compelling source for dielectric laser accelerator (DLA) beamlines, ultrafast electron diffraction, or ultrafast electron microscopy. Driven by a 220 fs, 1960 nm pulsed laser beam, electron currents up to 28 electrons/pulse at 100 kHz are demonstrated. The electron bunch length is 540 ± 50 fs for photocurrents of <1 electron/pulse, increasing to 700 ± 80 fs for 28 electrons/pulse, as measured by cross correlation with a 220 fs pulsed laser beam. The maximum 5D peak brightness is measured to be 6.8 × 10 13 A/(m 2 rad 2 ) at 28 electrons/pulse. These results represent a significant step toward developing practical benchtop-sized linear accelerators based on DLA technology or compact ultrafast electron microscopy and diffraction applications.

47 OTHER INSTRUMENTATION↗

Parametric Modeling of Transverse Phase Space of an RF Photoinjector

High brightness electron beam sources such as rf photo-injectors as proposed for SASE FELs must consistently produce the desired beam quality. We report the results of a study in which a combined neural network (NN) and first-principles (FP) model is used to model the transverse phase space of the beam as a function of quadrupole strength, while beam charge, solenoid field, accelerator gradient, and linac voltage and phase are kept constant. The parametric transport matrix between the exit of the linac section and the spectrometer screen constitutes the FP component of the combined model. The NN block provides the parameters of the transport matrix as functions of quad current. Using real data from SLAC Gun Test Facility, we will highlight the significance of the constrained training of the NN block and show that the phase space of the beam is accurately modeled by the combined NN and FP model, while variations of beam matrix parameters with the quad current are correctly captured. We plan to extend the combined model in the future to capture the effects of variations in beam charge, solenoid field, and accelerator voltage and phase.

43 PARTICLE ACCELERATORS↗

The SPARC linear accelerator based terahertz source

Ultra-short electron beams, produced through the velocity bunching compression technique, are used to drive the SPARC linear accelerator based source, which relies on the emission of coherent transition radiation in the terahertz range. This paper reports on the main features of this radiation, as terahertz source, with spectral coverage up to 5 THz and pulse duration down to 200 fs, with an energy per pulse of the order of several micro-joule, and as electron beam longitudinal diagnostics.

43 PARTICLE ACCELERATORS↗

Surface science analysis of GaAs photocathodes following sustained electron beam delivery

Degradation of the photocathode materials employed in photoinjectors represents a challenge for sustained operation of nuclear physics accelerators and high power Free Electron Lasers (FEL). Photocathode quantum efficiency (QE) degradation is due to residual gasses in the electron source vacuum system being ionized and accelerated back to the photocathode. These investigations are a first attempt to characterize the nature of the photocathode degradation, and employ multiple surface and bulk analysis techniques to investigate damage mechanisms including sputtering of the Cs-oxidant surface monolayer, other surface chemistry effects, and ion implantation. Surface and bulk analysis studies were conducted on two GaAs photocathodes, which were removed from the JLab FEL DC photoemission gun after delivering electron beam, and two control samples. The analysis techniques include Helium Ion Microscopy (HIM), Rutherford Backscattering Spectrometry (RBS), Atomic Force Microscopy (AFM) and Secondary Ion Mass Spectrometry (SIMS). In addition, two high-polarization strained superlattice GaAs photocathode samples, one removed from the Continuous Electron Beam Accelerator Facility (CEBAF) photoinjector and one unused, were also analyzed using Transmission Electron Microscopy (TEM) and SIMS. It was found that heat cleaning the FEL GaAs wafer introduces surface roughness, which seems to be reduced by prolonged use. The bulk GaAs samples retained a fairly well organized crystalline structure after delivering beam but shows evidence of Cs depletion on the surface. Within the precision of the SIMS and RBS measurements the data showed no indication of hydrogen implantation or lattice damage from ion back bombardment in the bulk GaAs wafers. In contrast, SIMS and TEM measurements of the strained superlattice photocathode show clear crystal damage in the wafer from ion back bombardment.

36 MATERIALS SCIENCE↗

High efficiency normal conducting linac for environmental water remediation

A continuous wave (CW) electron accelerator for the treatment of industrial streams including an electron beam source, a modified high efficiency slot coupled cavity, at least one focusing magnet positioned surrounding the accelerator to contain the beam in the accelerator, an efficient radio frequency power supply means for supplying power of a radio frequency to the cavity to induce a TM01 accelerating mode in the cavity, an electron beam spreader or raster, a fixed magnet array or two-dimensional scanning magnet for deflecting the accelerated beam into a desired shape, and an exit window for extracting the deflected electron beam. The accelerator includes a graded-beta cavity to enable use with a low-power pulsed electron source. The accelerator benefits from a low wall-power loss accelerating cavity that is energized with efficient RF sources, enabling it to be operated in continuous wave mode.

Hannon, Fay↗

Novel technique of suppressing TBBU in high-energy ERLs

Energy recovery linacs (ERLs) are an emerging generation of accelerators that promise to revolutionize the fields of high-energy physics and photon sciences. These accelerators combine the advantages of linear accelerators with that of storage rings, and augur the delivery of electron beams of unprecedented power and quality. However, one potential weakness of these devices is transverse beam break-up instability that could severely limit the available beam current. In this paper, I propose a novel method of suppressing these dangerous effects using the chromaticity of the transverse motion. In this short paper I am able only to touch the surface of the method and a complete description of the method with all relevant derivations can be found in [1].

43 PARTICLE ACCELERATORS↗

A proposal for antiparallel acceleration of positrons using CEBAF

Here, we present a scheme for positron beam acceleration in CEBAF antiparallel to the normal electron path, requiring no change in polarity of the magnet systems. This feature is essential to the principal benefit: enabling extremely simple configuration changes between conventional (clockwise) e - acceleration and counter clockwise e + acceleration. Additionally, it appears possible to configure the accelerating cavity phases to support concurrent acceleration of the electron and positron beams. The last mode also may enable use of the higher peak current electron beam for system diagnostics. The inherent penalty of the concurrent mode in acceleration efficiency and increased energy spread may render this a commissioning-only diagnostic option, but the possibility appears worthy of consideration.

43 PARTICLE ACCELERATORS↗

Development of Laser-Driven Proton and Electron Sources Using APRI 100-TW Ti:Sapphire Laser System

At the Advanced Photonics Research Institute (APRI) in Korea, we have a Ti:sapphire laser system which delivers laser pulses of 100-TW peak power and 32-fs pulse duration at the repetition rate of 10 Hz. This laser facility is being used to develop compact laser-driven proton and electron sources. Energetic protons are produced by irradiating the laser pulse on a thin foil target made of copper and polyimide via the target normal sheath acceleration. Proton beam with maximum energy of up to 4 MeV was generated from a polyimide target, and showed high energy conversion efficiency from laser to proton energy. Generation of high-energy electron beams by the laser wakefield acceleration was performed by focusing the laser pulses onto a 4 mm-long He-gas jet. Quasi-monoenergetic electron beam with peak energy of 45 MeV and maximum energy of 130 MeV was produced. The quality and characteristics of electron beams are strongly dependent on the laser-plasma interaction length which depends on focal length of the focusing optics.

43 PARTICLE ACCELERATORS↗