Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “electrical measurements”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 865 records · Page 48

Quantitative time-resolved diagnostics of electric field dynamics during individual plasma breakdown events using burst laser pulse electric field induced second harmonic generation

In plasma discharges, the acceleration of electrons by a fast varying electric field and the subsequent collisional electron energy transfer determines the plasma dynamics, chemical reactivity, and breakdown. Current in situ electric field measurements require reconstruction of the temporal profile over many observations. However, such methods are unsuitable for non-repetitive and unstable plasmas. Here, in this paper, we present a method for creating “movies” of dynamic electric fields in a single acquisition at sample rates of 500 × 10 6 fps. This ultrafast diagnostic was demonstrated in radio frequency electric fields between two parallel plates in air, as well as in Ar nanosecond-pulsed single-sided dielectric barrier discharges.

42 ENGINEERING↗

Empirical high-latitude electric field models

The present analysis of electric field measurements from the Dynamics Explorer 2 satellite, which extends previous empirical models, emcompasses much data from polar crossings entering and exiting the high latitudes in all magnetic local time zones. The goal is to represent the typical distributions of convective electric fields with a minimum number of characteristic patterns. Significant large-scale revisions of the OGO 6 dawn-dusk measurement models are made. The deformations of the two-cell patterns lead to sunward convection in dayside polar regions, while maintaining the integrity of the nightside convection pattern.

Heppner, J. P.↗

Measurement of dielectric properties and determination of microwave emissivity of polluted waters

The dielectric properties of polluted waters are measured with a reflection-type resonant cavity at 1.43 GHz. Very small water samples in quartz tubes of known volume are placed in the center of the maximum electric field. Measurement of the resonance-frequency variation and a change of the cavity's quality factor are used to determine the dielectric properties. The microwave emissivity of the polluted water is then calculated via the Fresnel equation and applied to data reductions of microwave radiometer measurements.

Blume, H.-J. C.↗

Voyager observations of lower hybrid noise in the Io plasma torus and anomalous plasma heating rates

A study of Voyager 1 electric field measurements obtained by the plasma wave instrument in the Io plasma torus has been carried out. A survey of the data has revealed the presence of persistent peaks in electric field spectra in the frequency range 100-600 Hz consistent with their identification as lower hybrid noise for a heavy-ion plasma of sulfur and oxygen. Typical wave intensities are 0.1 mV/m, and the spectra also show significant Doppler broadening, Delta omega/omega approximately 1. A theoretical analysis of lower hybrid wave generation by a bump-on-tail ring distribution of ions is given. The model is appropriate for plasmas with a superthermal pickup ion population present. A general methodology is used to demonstrate that the maximum plasma heating rate possible through anomalous wave-particle heat exchange is less than approximately 10 to the -14th ergs per cu cm per s. Although insufficient to meet the power requirement of the EUV-emitting warm torus, the heating rate is large enough to maintain a low-density (0.01-0.1 percent) superthermal electron population of keV electrons, which may lead to a small but significant anomalous ionization effect.

Barbosa, D. D.↗

Electrical Conductivity of Ferritin Proteins by Conductive AFM

Electrical conductivity measurements were performed on single apoferritin and holoferritin molecules by conductive atomic force microscopy. Conductivity of self-assembled monolayer films of ferritin molecules on gold surfaces was also measured. Holoferritin was 5-25 times more conductive than apoferritin, indicating that for holoferritin most electron-transfer goes through the ferrihydrite core. With 1 V applied, the average electrical currents through single holoferritin and apoferritin molecules were 2.6 PA and 0.19 PA, respectively.

Xu, Degao↗

The EDR Inflow Region of a Reconnecting Current Sheet in the Geomagnetic Tail

On 6 July 2017, the four Magnetospheric Multiscale spacecrafts were positioned within an electron diffusion region (EDR) just northward of a reconnection X line. The EDR was identified by electron crescent distributions, out-of-plane current, and energy conversion. From this position, the three spacecrafts closest to the X line (within about three electron inertial lengths) were able to accurately measure the reconnection electric field and the electron inflow velocity. The reconnection rates derived from the electric field and inflow velocity measurements agree with theoretical estimates (0.11–0.17) and a previous measurement of EM in a tail reconnection event on 11 July 2017.

Energy conversion↗

Delta-Doped CCDs as Detector Arrays in Mass Spectrometers

In a conventional mass spectrometer, charged particles (ions) are dispersed through a magnetic sector onto an MCP at an output (focal) plane. In the MCP, the impinging charged particles excite electron cascades that afford signal gain. Electrons leaving the MCP can be read out by any of a variety of means; most commonly, they are post-accelerated onto a solid-state detector array, wherein the electron pulses are converted to photons, which, in turn, are converted to measurable electric-current pulses by photodetectors. Each step in the conversion from the impinging charged particles to the output 26 NASA Tech Briefs, February 2007 current pulses reduces spatial resolution and increases noise, thereby reducing the overall sensitivity and performance of the mass spectrometer. Hence, it would be preferable to make a direct measurement of the spatial distribution of charged particles impinging on the focal plane. The utility of delta-doped CCDs as detectors of charged particles was reported in two articles in NASA Tech Briefs, Vol. 22, No. 7 (July 1998): "Delta-Doped CCDs as Low-Energy-Particle Detectors" (NPO-20178) on page 48 and "Delta- Doped CCDs for Measuring Energies of Positive Ions" (NPO-20253) on page 50. In the present developmental miniature mass spectrometers, the above mentioned miniaturization and performance advantages contributed by the use of delta-doped CCDs are combined with the advantages afforded by the Mattauch-Herzog design. The Mattauch- Herzog design is a double-focusing spectrometer design involving an electric and a magnetic sector, where the ions of different masses are spatially separated along the focal plane of magnetic sector. A delta-doped CCD at the focal plane measures the signals of all the charged-particle species simultaneously at high sensitivity and high resolution, thereby nearly instantaneously providing a complete, high-quality mass spectrum. The simultaneous nature of the measurement of ions stands in contrast to that of a scanning mass spectrometer, in which abundances of different masses are measured at successive times.

Nikzad, Shouleh↗

Tides on South Mill Apartment Complex

This dataset includes data from the building management system for a large multi-family rental property located in Tempe, Arizona. The name of this rental property is “Tides on South Mill” and it is owned by the FCP which is a real-estate investment company based in Maryland with a large portfolio of rental properties that spreads out throughout the U.S. FCP’s portfolio includes large multi-family housing and commercial buildings. The property is split into four quadrants. Each quadrant has roughly 130 apartments. The total floor area of each Quadrant is about 94,000 sq. ft. The campus of Solara spreads over 27 acres. The mechanical system consists of a 2-pipe system that runs chilled or hot water thru individual Fan Coil Units depending upon the season. The gas-fired boiler will supply hot water when seasonal change-over will take place. This dataset spans October to December 2021 and includes time-series measurements corresponding electricity meter data (Cooling Tower Fan, Pumps, Chillers,) with 1-minute resolution, chilled water temperature data and outside air data with 5-minute resolution etc. as CSV files. In addition to the measurements, a metadata .json file, and a .pdf dataset description file are also included.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy deposition and middle atmosphere electrodynamic response to a highly relativistic electron precipitation event

Rocket data have been used to evaluate the characteristics of precipitating relativistic electrons and their effects on the electrodynamic structure of the middle atmosphere. These data were obtained at Poker Flat, Alaska, on May 13 and 14, 1990, during a midday, highly relativistic electron (HRE) precipitation event. Solid state detectors were used to measure the electron fluxes and their energy spectra. An X ray scintillator was included on each flight to measure bremsstrahlung X rays produced by energetic electrons impacting on the upper atmosphere. However, these were found the be of negligible importance for this particular event. The energy deposition by the electrons has been determined from the flux measurements and compared with in situ measurements of the atmospheric electrical response. The electrodynamic measurements were obtained by the same rockets and additionally on May 13, with an accompanying rocket. The impact flux was highly irregular, containing short-lived bursts of relativistic electrons, mainly with energies below 0.5 MeV and with fluxes most enhanced between pitch angles of 0 deg - 20 deg. Although the geostationary counterpart of this measured event was considered to be of relatively low intensity and hardness, energy deposition peaked near 75 km with fluxes approaching an ion pair production rate in excess of 100/cu cm s. This exceeds peak fluxes in relativistic electron precipitation (REP) events as observed by us in numerous rocket soundings since 1976. Conductivity measurements from a blunt probe showed that negative electrical conductivities exceeded positive conductivities down to 50 km or lower, consistent with steady ionization by precipitating electrons above 1 MeV. These findings imply that the electrons from the outer radiation zone can modulate the electrical properties of the middle atmosphere to altitudes below 50 km. During the decline and activity minimum of the current solar cycle, we anticipate the occurence of similar events but with fluxes 1-2 orders of magnitude above that reported here, based on studies of earlier solar cycles (e.g., Baker et al., 1993).

Goldberg, R. A.↗

Electrical properties of epoxies and film resistors

The reliability of hybrid microcircuits has been enhanced in recent years by the use of organic adhesives as a replacement for solder and eutectics. The epoxies have been the most effective and widely used material for this application. Methods for measuring the electrical and mechanical properties of epoxies are developed. Data are given for selected conductive adhesives at high and low frequencies. The temperature coefficients of resistance of thick film resistors are presented.

Sergent, J. E.↗

Detectors Ensure Function, Safety of Aircraft Wiring

Pedro Medelius waited patiently in his lab at Kennedy Space Center. He had just received word that a colleague was bringing over a cable from a Space Shuttle solid rocket booster to test Medelius new invention. Medelius was calm until his colleague arrived, with about 30 other people. "Talk about testing under pressure," says Medelius. "There were people there from the Navy, the Air Force, and the Federal Aviation Administration." After the group s arrival, Medelius took a deep breath and connected his Standing Wave Reflectometer (SWR) to the cable. He wiggled the cable around, and the display showed a fault (a short or open circuit in wire) about an inch and a half inside the connector on the cable. His colleague questioned the results, because he had already checked that area on the cable. Medelius used the SWR to check again but got the same result. "That is when we took the cable apart and looked inside," Medelius says. "Lo and behold, that was exactly where the fault was." The impetus for Medelius new wire inspection technology came about in 1999 when one of the space shuttles lost power due to a fault somewhere in its more than 200 miles of electrical wiring. "The backup circuit was activated and prevented a major dysfunction, but nevertheless, there was a problem with the wiring," Medelius describes. Even though technicians used a device called a multimeter to measure the electrical current to find which wire had a fault, it could not pinpoint exactly where on the wire the fault was located. For that, technicians had to visually inspect the wire. "Sometimes they would have to remove the whole wire assembly and visually inspect every single wire. It was a very tedious operation because the wires are behind cabinets. They go all over the place in the shuttle," says Medelius. "NASA needed an instrument capable of telling them exactly where the faults were occurring." To meet NASA s needs for a highly precise device to inspect electrical power bundles, wires, and connectors, Medelius devised the SWR. "It came down to what was affected when a wire is short circuited or opened," he says. "We worked out a few equations based on physical principles." The SWR proved very sensitive, and the technology was patented.

Source record↗

Single-shot measurements of shaped XUV FEL pulses with frequency-resolved optical gating

The ability to control the amplitude and phase of extreme ultraviolet (XUV) and X-ray free-electron laser (FEL) pulses can allow for the extension of optical techniques, such as multidimensional spectroscopy or coherent control, to higher photon energies, for probing and controlling core electronic transitions. However, this requires the ability to make single-shot, and complete, electric field measurements of potentially complex FEL pulses, in order to develop, and verify, pulse shaping strategies. Here, we present direct, single-shot measurements of XUV pulses generated under special operating configurations for producing specific pulse shapes from a laser-seeded XUV FEL. To do this, we built upon our past work using transient grating (TG) cross correlation frequency-resolved optical gating (FROG), where an optical reference pulse is diffracted from an XUV TG produced by a pair of interfering FEL pulses. The resulting nonlinear signal versus frequency and delay, i.e., the FROG trace, contains the electric field of the FEL pulse. The FEL pulse electric field is reconstructed from the FROG trace using a phase retrieval algorithm. Here we confirmed three different pulse shaping strategies for generating chirped, double and multiple FEL pulses by tuning the seed laser and FEL parameters and measuring the resulting shaped FEL pulses with TG XFROG. This work paves the way for generating on-demand pulse shapes with a seeded FEL by improving the characterization of FEL pulses, for transform-limited to more complex shapes.

Elverson, Francesca↗

Photodiode-Based, Passive Ultraviolet Dosimeters

Simple, passive instruments have been developed for measuring the exposure of material specimens to vacuum ultraviolet (VUV) radiation from the Sun. Each instrument contains a silicon photodiode and a coulometer. The photocharge generated in the photodiode is stored in the coulometer. The accumulated electric charge measured by use of the coulometer is assumed to be proportional to the cumulative dose of VUV radiation expressed in such convenient units as equivalent Sun hours (ESH) [defined as the number of hours of exposure to sunlight at normal incidence]. Intended originally for use aboard spacecraft, these instruments could also be adapted to such terrestrial uses as monitoring the curing of ultraviolet-curable epoxies. Each instrument includes a photodiode and a coulometer assembly mounted on an interface plate (see figure). The photodiode assembly includes an aluminum housing that holds the photodiode, a poly(tetrafluoroehylene) cosine receptor, and a narrow-band optical filter. The cosine receptor ensures that the angular response of the instrument approximates the ideal angular response (proportional to the cosine of the angle of incidence). The filter is chosen to pass the ultraviolet wavelength of interest in a specific experiment. The photodiode is electrically connected to the coulometer. The factor of proportionality between the charge stored in the coulometer and ultraviolet dosage (in units of ESH) is established, prior to use, in calibration experiments that involve the use of lamps and current sources traceable to the National Institute of Standards and Technology.

Vaughn, Jason A.↗

Formation of misfit dislocation arrays and helium nanochannels near copper surface assisted by high-temperature graphene deposition

Misfit dislocation arrays (MDAs) at semi-coherent heterogeneous interface have been demonstrated effectiveness to trap and then outgas helium (He) for alleviating void swelling in metals, but limited by atomic-level thin film deposition that is difficult to scale-up for industrial production. In this work, we proposed an innovative strategy that could generate semi-coherent homophase interfaces in a same grain by varying surface energy density assisted by high-temperature graphene (Gr) deposition. This strategy transforms strain energy and surface energy, two originally distinctive processes into successive processes, and demonstrates experimentally and theoretically by introducing {111} copper (Cu) in a {100} Cu grain. Subsequent He implantation and electrical resistivity measurement results suggest that high-density MDAs originated at this {111}/{100} interface could form stable He nanochannels near Cu surface with Gr assistance, manifesting by ultra-low increased ratio of the electrical resistivity (i.e. ~3800% of Cu vs. ~90% of Gr/Cu) after He implantation. Finally, the present findings may provide a new strategy for efficiently managing He and achieving surface protection of advanced metals, merely by depositing a super-rigid material on metal surface to greatly reduce surface energy density.

36 MATERIALS SCIENCE↗

Large magnetoresistance and first-order phase transition in antiferromagnetic single-crystalline EuAg 4 Sb 2

Here, we present the results of a thorough investigation of the physical properties of EuAg 4 Sb 2 single crystals using magnetization, heat capacity, and electrical resistivity measurements. High-quality single crystals, which crystallize in a trigonal structure with space group 𝑅⁢$\bar{3}$𝑚, were grown using a conventional flux method. Temperature-dependent magnetization measurements along different crystallographic orientations confirm two antiferromagnetic phase transitions around 𝑇 𝑁⁢1 = 10.5K and 𝑇 𝑁⁢2 = 7.5K. Isothermal magnetization data exhibit several metamagnetic transitions below these transition temperatures. Antiferromagnetic phase transitions in EuAg 4 Sb 2 are further confirmed by two sharp peaks in the temperature-dependent heat capacity data at 𝑇 𝑁⁢1 and 𝑇 𝑁⁢2 , which shift to lower temperature in the presence of an external magnetic field. Our systematic heat capacity measurements utilizing a long-pulse and single-slope analysis technique allow us to detect a first-order phase transition in EuAg 4 Sb 2 at 7.5 K. The temperature-dependent electrical resistivity data also manifest two features associated with magnetic order. The magnetoresistance exhibits a broad hump due to a field-induced metamagnetic transition. Remarkably, the magnetoresistance keeps increasing without showing any tendency to saturate as the applied magnetic field increases, and it reaches ∼20 000% at 1.6 K and 60 T. At high magnetic fields, several magnetic quantum oscillations are observed, indicating a complex Fermi surface. A large negative magnetoresistance of about −55% is also observed near 𝑇 𝑁⁢1 . Moreover, the 𝐻−𝑇 phase diagram constructed using magnetization, heat capacity, and magnetotransport data indicates complex magnetic behavior in EuAg 4 Sb 2 .

36 MATERIALS SCIENCE↗

Investigation of mid-latitude ionospheric currents by combined rocket techniques.

A comprehensive range of neutral atmospheric and simultaneous ionospheric structure measurements were obtained from a Skylark rocket launched at Woomera during evening twilight on a quiet magnetic day. Above 150 km, good agreement was found between the results obtained from three different methods of electric field measurement despite the low field strength (about 1.5 mV/m). In the immediate vicinity of an intense sporadic E layer, the probe measurements indicated large excursions of the electrostatic field amounting to 6.5 mV/m at 105.3 km and 2.7 mV/m at 104.8 km. The calculated ionospheric current system in the vicinity of the rocket trajectory was of similar magnitude to that indicated by local ground-based magnetometers, but was diametrically opposed in direction.

Rees, D.↗

Quantitative simulation of a magnetospheric substorm. II - Comparison with observations

Results of the computer simulation of the behavior of the inner magnetosphere during the substorm-type event of September 19, 1976, are discussed. The computed electric fields are found to compare satisfactorily with electric fields measured from S3-2, although there are detailed differences. The three general features on which the model and observations are in good agreement are (1) the magnitude and direction of the high-latitude electric field, (2) the degree to which the low-latitude ionosphere is shielded from the high-latitude convection electric field, and (3) the fact that the poleward electric field on the duskside is significantly larger, on the average, than the equatorward electric field on the dawnside. Simple formulas are presented that give rough estimates of global Joule heating rates from observable parameters.

Harel, M.↗