Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “electric load”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 865 records · Page 48

Shape Matters: Understanding the Effect of Electrode Geometry on Cell Resistance and Chemo-Mechanical Stress

Rechargeable batteries that incorporate shaped three-dimensional electrodes have been shown to have increased power and energy densities when compared to a conventional geometry, i.e. a planar cathode and anode that sandwich an electrolyte. Electrodes can be shaped to enable a higher active material loading, while keeping ion transport distances small. However, the relationship between electrical and mechanical performance of shaped electrodes remains poorly understood. Many electrode designs have been explored, where the electrodes are individually shaped or intertwined, and advances in manufacturing and shape/topology optimization have made such designs a reality. Here, we explore sinusoidal half cells and interdigitated full cells. First, we use a simple electrostatics model to understand the cell resistance as a function of shape. Here we focus on low-temperature conditions, where the electrolyte conductivity decreases relative to that of the electrode; here, LiPF 6 EC:DMC electrolyte and MnO 2 electrode are considered. Next, we use a chemo-mechanics model to examine the stress that arises due to intercalation-driven volume expansion. We show that shaped electrodes provide a significant reduction in resistance in low-temperature conditions, however, they exhibit unfavorable stress concentrations. Overall, we find that the fully interdigitated electrodes may provide the best balance with respect to this resistance-stress trade-off.

25 ENERGY STORAGE↗

DEPRECATED EVOLVE [SWR-20-79]

DEPRECATED This repository was archived by the owner on Jun 30, 2026. It is now read-only. EVOLVE is a combination of a dashboard developed in React, which enables user to visualize the net load evolution with emerging technologies such as PV, energy storage, and electric vehicles, and a Python backend processes data. A user can choose settings for solar, energy storage, and electric vehicles in the dashboard. Modules that are developed to model the impact of these DERs can also be used independently without being integrated into the dashboard. We used a RESTful API to expose these modules to the React front-end.

Duwadi, Kapil↗

GridSTAGE (aka PowerDrone)

Simulation tool for electrical grid security. It is possible to select from pre-loaded power system topologies, enable different grid controls (like AGC, power system stabilizer), add faults, tweak different parameters, add pre-modeled attack scenarios, and run batch simulations to generate data needed for research.

Nandanoori, Sai Pushpak↗

Final Report for ARPA-E NODES "Real-Time Optimization and Control of Next-Generation Distribution Infrastructure" Project

The project examined next-generation power distribution systems with high levels of power- electronics-interfaced distributed energy resources (DERs) that include: renewable energy systems (RESs), energy-storage devices, electric vehicles, fuel cells, small-scale diesel generators, and controllable loads. The project developed a comprehensive distribution- network management framework that unifies real-time voltage and frequency control with network-wide energy management under an integrated framework. The aim of the project was to: i) systematically optimize network-wide operation and congruently regulate voltages and frequency in the face of high volatility induced by rapidly varying RES and uncontrolled loads; ii) facilitate high renewable integration beyond 50% on an energy basis; iii) meet power-quality requirements and operational constraints; and, iv) respect response, ramp- time, and hold-time requirements for synthetic frequency and regulating reserves via fast- and longer-term dynamic energy management.

24 POWER TRANSMISSION AND DISTRIBUTION↗

NG-CT Peaker Upgrades with Bottoming Cycle: Preliminary Analysis

The National Energy Technology Laboratory (NETL) has conducted a preliminary analysis exploring a significant opportunity to increase the nation's power grid capacity and reliability. The study focuses on retrofitting under-utilized natural gas combustion turbines (NG-CTs), often called "peaker" plants, with a bottoming cycle to capture waste heat and generate additional electricity. This analysis shows that upgrading these existing assets could add approximately 26,250 MW of new power capacity across the United States. A detailed study of the PJM Interconnection, the nation's largest grid operator, confirmed the benefits of these upgrades. Key findings for the PJM region include: - A median increase in the plants' capacity factor by 17 percentage points. - A projected 36.2% median reduction in the levelized cost of electricity (LCOE) for the upgraded plants, with nearly 88% of them expected to break even. - An average reduction in the regional wholesale price of electricity by approximately 3.0% in the year 2030. - A significant boost to grid reliability, with a 46% reduction in projected Loss of Load Hours (LOLH). These findings suggest that retrofitting peaker plants is a promising and economically viable strategy to enhance grid performance, reduce electricity costs, and meet future demand without the challenges associated with building entirely new facilities.

bottoming cycle↗

Sample IEEE123 Bus system for OEDI SI

Time series load and PV data from an IEEE123 bus system. An example electrical system, named the OEDI SI feeder, is used to test the workflow in a co-simulation. The system used is the IEEE123 test system, which is a well studied test system (see link below to IEEE PES Test Feeder), but some modifications were made to it to add some solar power modules and measurements on the system. The aim of this project is to create an easy-to-use platform where various types of analytics can be performed on a wide range of electrical grid datasets. The aim is to establish an open-source library of algorithms that universities, national labs and other developers can contribute to which can be used on both open-source and proprietary grid data to improve the analysis of electrical distribution systems for the grid modeling community. OEDI Systems Integration (SI) is a grid algorithms and data analytics API created to standardize how data is sent between different modules that are run as part of a co-simulation. The readme file included in the S3 bucket provides information about the directory structure and how to use the algorithms. The sensors.json file is used to define the measurement locations.

123 bus↗

Multi-layered Resilient Microgrid Networks

Distribution grid resilience, especially when the grid is under high penetration of Distributed Energy Resources (DER), e.g. PV and energy storage, is essential to ensure the quality of electric power services. The resiliency aspect is particularly important for critical loads that typically include hospitals, police/fire stations, and national security facilities. Networks of multiple interconnected reconfigurable microgrids help to increase renewable energy penetration and may be used as basic building blocks for implementing future resilient power grids. However, this integration requires additional layers of communications, both horizontal and vertical, which may substantially increase the potential cyber attack surfaces as well as escalate risks for wide-spread malfunctions of automation systems. The Mulit-layered Resilient Microgrid Networks project is an industry-academic collaboration between ABB, Duke Energy and the University of Illinois at Urbana-Champaign (UIUC) that has developed and demonstrated a cyber-physical resilient control and communication architecture for deployment of multiple microgrid networks, as well as retrofitting the existing distribution grids by increasing DER penetration levels.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Topological Machine Learning Methods for Power System Responses to Contingencies: Preprint

While deep learning tools, coupled with the emerging machinery of topological data analysis, are proven to deliver various performance gains in a broad range of applications, from image classification to biosurveillance to blockchain fraud detection, their utility in areas of high societal importance such as power system modeling and, particularly, resilience quantification in the energy sector yet remain untapped. To provide fast acting synthetic regulation and contingency reserve services to the grid while having minimal disruptions on customer quality of service, we propose a new topologybased system that depends on neural network architecture for impact metrics classification and prediction in power systems. This novel topology-based system allows one to evaluate the impact of three power system contingency types, namely, in conjunction with transmission lines, transformers, and transmission lines combined with transformers. We show that the proposed new neural network architecture equipped with local topological measures facilitates both more accurate classification of unserved load as well as the amount of unserved load. In addition, we are able to learn complex relationships between electrical properties and local topological measurements on the simulated response to contingencies for NREL-SIIP power system.

graph theory↗

Current generation from radiation with diamond diode-based devices for detection or power generation

Diamond diode-based devices are configured to convert radiation energy into electrical current, useable for sensing (i.e., detection) or delivery to a load (i.e., energy harvesting). A diode-based detector includes an intrinsic diamond layer arranged between p-type diamond and n-type diamond layers, with the detector further including at least one of (i) a boron containing layer arranged proximate to the n-type and/or the intrinsic diamond layers, or (ii) an intrinsic diamond layer thickness in a range of 10 nm to 300 microns. A diode-based detector may be operated in a non-forward biased state, with a circuit used to transmit a current pulse in a forward bias direction to reset a detection state of the detector. An energy harvesting device may include at least one p-i-n stack (including an intrinsic diamond layer between p-type diamond and n-type diamond layers), with a radioisotope source arranged proximate to the at least one p-i-n stack.

Holmes, Jason M.↗

To What Extent Will Decarbonization Deepen the Conversation Between Industry and the Grid?

Decarbonization - the transition away from un-mitigated fossil fuel combustion throughout the economy - requires big changes from both power and process systems. On the power system side, those changes are expected to include large increases in variable generation, e.g., from wind and solar, which has near-zero marginal costs and at large shares can produce infrequent but consequential energy droughts. On the process systems side, industries are investigating their options for direct and indirect electrification, the latter exemplified by replacing fossil fuel inputs with zero-carbon, energy-carrying chemicals like hydrogen and ammonia produced via electrochemical processes. The economic features of these changes within the larger context of power and process systems suggest that their realization could be accompanied by a paradigm shift in how industrial facilities interact with the grid. For example, the dominant type of demand participation in power markets could change from today's focus on load reductions at peak times to a new focus on shifting electricity use, enabled in part by large-scale product storage, to take advantage of renewable energy that would otherwise be curtailed and to avoid consumption during high-price energy droughts. This talk will describe these and other possible design and operational approaches from grid and industrial economic perspectives, culminating in an enumeration of open problems that lie at the interface of today and tomorrow's power and process systems.

co-design↗

Novel Air System for 300 kW Heavy Duty Fuel Cell

Hydrogen fuel cell powered vehicles for heavy duty trucks is a potential path for reducing heavy duty vehicle emissions in the future. The air handling system delivers the proper amount of air (oxygen) to react with fuel (hydrogen) in the fuel cell to produce power. Air delivery requires significant power and is the largest parasitic loss for a 300 kW fuel cell. Today’s systems use an electric motor to power an air compressor that supplies oxygen to the fuel cell stack. In addition to parasitic power loss, hydrogen fuel cell systems often have reliability issues associated with the air handling system. Reliability is of significant concern for heavy duty applications (especially long-haul applications). This project aims to improve both the electrical power consumption and reliability of hydrogen fuel cell air handling systems to meet the needs of heavy duty on-highway vehicle applications. The air handling is provided by a twin vortices series (TVS) compressor in addition to adding a TVS expander to recover waste heat energy back into the compressor. The final configuration includes a 600 V, 39 kW motor connected with a single shaft to the compressor and expander. This configuration reduced the total electrical power consumption from 48.6 kW to 37 kW at full load, 27 kW to 9 kW at half load and 0.44 kW to 0.22 kW at idle. The response time requirement was to be less than 2 seconds while the final demonstration yielded 0.62 sec. The study includes additional technologies including water dosing into the compressor, a recuperator and elimination of the intercooler.

Reich, Evan [Eaton Corporation, Southfield, MI (Un↗

Field Demonstration of Residential DER Service-Oriented Load Participation

Amidst a concerning surge in power consumption during peak hours, coupled with heightened power grid instability, and driven by a growing demand for electricity, aggregations of Distributed Energy Resource are becoming a viable means for providing essential reliability services.Electric utility companies have proactively implemented Demand Response programs for decades. These programs employ Direct Load Control methods to enhance power grid stability, achieved by controlling customers’ Distributed Energy Resource during peak hours to reduce power consumption. However, a notable drawback of Direct Load Control has been high unenrollment rates of DR program participants due to customer discomfort.Therefore, the underlying issue of over-consumption persists. To address these concerns, this paper introduces a Service-Oriented Load Participation approach to providing grid services such as Demand Response. Leveraging a Service-Oriented Architecture, this method offers the advantage of efficient service management and provisioning within the system. The SOLP approach not only aims to reduce power consumption but also to maintain customer satisfaction by ensuring a comfortable grid service experience.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Controlled workplace charging of electric vehicles: The impact of rate schedules on transformer aging

To accelerate adoption of non-residential charging for electric vehicles, sites must maximize utilization of existing electrical infrastructure. In this study we model electric vehicle charging at a workplace using real charging data and evaluate the lifetime of the site’s transformer as the number of charging stations is incrementally increased. We implement and compare a range of control schemes for workplace charging including minimizing the peak load, capping the total load, minimizing bills under different rate structures with time-of-use energy costs and demand charges, and directly minimizing the transformer’s aging. These are compared by the number of vehicles they allow the transformer to support, the transformer’s health, and the operator’s electricity bill. We draw a connection between minimizing the peak load and improving the transformer’s health. We observe that minimizing the electricity bill is the best scheme by both criteria when the bill includes a demand charge; in our experiment it allowed the infrastructure to support over 67% more cars than under uncontrolled charging. To protect the transformer we recommend that demand charges or capacity management be applied to parking lots of charging electric vehicles with high infrastructure utilization, and operators schedule charging to minimize their electricity bills.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Unitary Thermal Energy Management for Propulsion Range Augmentation (UTEMPRA) (CRADA Final Report)

NREL will work with Delphi to develop technology that integrates the thermal management of electric drive vehicle sub-systems into a unified thermal system that reduces auxiliary loads and increases vehicle range. The ultimate goal is to create a cost-effective system which improves climate control efficiency through heat pump operation and waste heat recovery, while maintaining occupant thermal comfort and meeting powertrain thermal requirements. The technology will also aim to reduce the number of independent cooling systems required in electric drive vehicles.

33 ADVANCED PROPULSION SYSTEMS↗

Methods for Computing Physically Realistic Estimates of Electric Water Heater Demand Response Resource Suitable for Bulk Power System Planning Models

Demand response is commonly called on to reduce load during system peak times or to respond to contingency events. In future power systems with higher shares of wind and solar generation (which we describe together as variable generation [VG]), demand response could have more opportunities to provide energy shifting or operating reserve services. This report evaluates the ability of residential electric water heaters, both electric resistance water heaters (ERWHs) and heat pump water heaters (HPWHs), to provide such services starting from detailed whole-building energy models that realistically represent New England single family home stock. We use a parsimonious surrogate model to represent operational flexibility in a form suitable for linear and mixed integer programming. This enables relatively fast determination of aggregate contingency reserve resource, price-taking energy shifting outcomes, and in some cases the determination of aggregate models at the megawatt (MW) scale that can be directly included in large-scale grid models. After selecting modeling methods and parameters through various computational experiments, we find interquartile ranges of contingency reserve resource in ISO-NE for about 603,400 ERWHs of 45 MW - 69 MW for Claim10 (50 minute responses provided with 10 minutes of advanced notification) and 65 MW - 102 MW for Claim30 (30 minute responses provided with 30 minutes of advanced notification), and for about 619,000 HPWHs of 48 MW - 88 MW for Claim10 and 52 MW - 90 MW for Claim30. The overall reserve resource is up to 32% of total load for ERWHs providing Claim10 service, 47% for ERWHs providing Claim30 service, 93% for HPWHs providing Claim10 service, and 97% for HPWHs providing Claim30 service. More work is required to determine if HPWHs are inherently more suitable than ERWHs for providing contingency reserve or if these results reflect idiosyncrasies of the single family home stock model used in this study. The value of this contingency resource in a Near-term VG model of ISO-NE is $\$ 0.40$ to $\$1.20$ per water heater-year, and significantly larger, $\$ 3.80$ to $\$ 5.30$ per water heater-year in a Mid-term VG model of ISONE. Aggregating surrogate models to the MW-scale for energy shifting service is more challenging than for contingency service and we only present such results for ERWHs, because we were unable to determine satisfactory ways to deal with HPWHs' time-varying and path dependent operational characteristics. Individual surrogate models suitable for evaluating the energy shifting resource from both ERWHs and HPWHs are created, however, and dispatched against day-ahead prices from the Near-Term VG and Mid-Term VG models of ISO-NE. The individual surrogate models are able to access and potentially shift all 640 GWh of HPWH load and 1,547 GWh of ERWH load we modeled in two different single family home stock models. In contrast, the most effective model of aggregate ERWH shifting resource we created only captured 34.7% of the total ERWH load. Energy shifting affected by price-taking dispatch against modeled day-ahead energy prices produces per water heater year profits of $\$19.44$ - $\$22.93$ for individual HPWHs, $\$39.11$ - $\$40.54$ for individual ERWHs, and up to $\$4.00$ - $\$4.24$ for aggregated ERWHs, with the variations mainly due to grid conditions (more or less VG). When the supply-side response to these changes is accounted for, the per water heater year production cost savings for ISO-NE are $\$7.50$ to $\$17.70$ for the most effective set of endogenously dispatched aggregate ERWHs, $\$15.60$ to $\$15.70$ for individual ERWHs dispatched against the DA prices, and $\$10.70$ to $\$11.20$ for individual HPWHs dispatched against DA prices. Those ranges primarily represent the difference between Near-Term VG and Mid-Term VG grid conditions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The impact of energy-efficiency upgrades and other distributed energy resources on a residential neighborhood-scale electrification retrofit

We report ambitious targets for carbon emissions reductions are highlighting new challenges for electrification strategies, leading to an increased focus on building load flexibility and energy management to complement the variability inherent in renewable energy generation. Over the next decade millions of existing homes could undergo electrification retrofits, and there is an urgent need to understand the potential impacts of electrifying major residential loads such as water and space heating on community load characteristics, resident energy bills, and the utility's distribution system. Behind-the-meter distributed energy resources (DERs), including efficiency measures, photovoltaics (PV), battery storage, managed electric vehicle (EV) charging, and controls such as home energy management systems (HEMS), can significantly alter a neighborhood's load profile and provide benefits to both the residents and the grid. We present a novel approach to characterizing the impact of a hypothetical neighborhood-scale residential retrofit program on individual homes' energy use profiles, associated utility bills, and the local distribution system. We modeled a mixed-fuel community of 30 single-family homes in Denver, Colorado, and compared the effects of retrofit scenarios ranging from conventional energy-efficiency upgrades to full electrification with and without more advanced DER technologies. We analyzed which packages of DERs most reliably enable demand flexibility in response to a time-of-use (TOU) rate for this and similar neighborhoods. Our buildings-to-grid co-simulation framework includes a generic secondary distribution feeder model to capture voltage profiles, transformer loading, and other grid impacts in each case. We also calculated the carbon emissions associated with energy use in the community. The methodology developed here can be broadly applied to community-scale beneficial electrification studies in other regions, climates, utility infrastructures, and building typologies to make specific, targeted recommendations based on quantified projections of energy demand in any given community. Our findings indicate that residential electrification can be achieved without negatively impacting the monthly utility bill, and that a combination of conventional energy-efficiency measures, PV, battery, controls, and managed EV charging to maximize a community's demand flexibility is a promising strategy. Adding DERs (especially PV) as part of efficient electrification produces much bigger savings than efficient electrification without DERs. A key barrier is that upgrades require upfront costs, and modest utility bill savings result in long payback periods.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Commercial building HVAC demand flexibility with model predictive control: Field demonstration and literature insights

Model Predictive Control (MPC) for building Heating Ventilation and Air Conditioning (HVAC) systems is beginning to gain traction in the market, with a few controls companies incorporating it into their product offerings. However, it remains difficult to assess whether the energy cost savings are enough to justify the cost of MPC implementation for a particular building, given the limited number of reported demonstrations. For small commercial and residential buildings with relatively uniform systems, standardized approaches can help lower implementation costs. In contrast, for large buildings or district systems, the potential magnitude of cost savings could justify more customized solutions. Estimating the cost-effectiveness of MPC becomes more challenging for medium and large commercial buildings, where a one-size-fits-all solution may not be suitable, and the potential energy cost savings may be insufficient to justify a customized solution. To make MPC technology more appealing, incorporating additional value streams beyond energy efficiency alone can significantly increase its attractiveness. One such revenue stream is demand flexibility, in response to dynamic electricity prices, where MPC can leverage the thermal mass of the building to shift the load and support the grid. Building on an extensive literature review of MPC field studies focused on cost savings and demand flexibility, this paper presents the results of implementing MPC control in a large office building HVAC system in Berkeley, CA. Four different dynamic electricity price profiles were integrated into the MPC objective function to shift building demand while maintaining comfort, and field testing was performed with each price profile across four seasons. The results show potential for 40–65 % demand decrease percentage and up to 61 % annual cost savings compared to the existing rule-based control strategy, under the tested dynamic price scenarios. This paper also presents a sensitivity analysis on the cost savings with respect to the price profile variability, discusses the implementation effort for the price-responsive MPC, and compares the cost savings found in this study to those found in literature on the basis of dynamic price variability, or so-called Electricity Price Relative Standard Deviation.

Zanetti, Ettore↗

Coupled aero-hydro-geotech real-time hybrid simulation of offshore wind turbine monopile structures

Real-time hybrid simulation (RTHS) divides a structural system into an analytical and experimental substructure. The former is based on a well-established analytical model while the latter consists of a physical model in the laboratory, for which there is not a well-established analytical model. This paper extends real-time hybrid simulation to monopile-type Offshore Wind Turbines (OWTs) to enable the investigation of their behavior considering the response of pile foundations under operational and more severe conditions. The embedded foundation and surrounding soil of the OWT are modeled physically in a soil box in the laboratory while the remaining parts of the system and loading are modeled analytically. The program OpenFAST, developed by the National Renewable Energy Laboratory (NREL), is linked to the RTHS coordinator to determine the hydrodynamic and aerodynamic loads acting on the OWT, along with modeling the dynamics of the electric power generation equipment and associated controller for the OWT. The RTHS framework along with its initial implementation and validation are described in this paper. RTHSs of a 5 MW OWT subjected to operational and more severe conditions are performed to experimentally validate the framework. The framework offers a realistic approach to investigate the behavior of OWT structures supported on monopiles. Furthermore, this approach accounts for the coupled response of the OWT structure with its foundation, while experimentally capturing the nonlinearities of the soil-foundation interaction in real-time.

17 WIND ENERGY↗