Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “eclipse”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 865 records · Page 48

Dosimetric impact of image artifact from a wide-bore CT scanner in radiotherapy treatment planning

Purpose: Traditional computed tomography (CT) units provide a maximum scan field-of-view (sFOV) diameter of 50 cm and a limited bore size, which cannot accommodate a large patient habitus or an extended simulation setup in radiation therapy (RT). Wide-bore CT scanners with increased bore size were developed to address these needs. Some scanners have the capacity to reconstruct the CT images at an extended FOV (eFOV), through data interpolation or extrapolation, using projection data acquired with a conventional sFOV. Objects that extend past the sFOV for eFOV reconstruction may generate image artifacts resulting from truncated projection data; this may distort CT numbers and structure contours in the region beyond the sFOV. The purpose of this study was to evaluate the dosimetric impact of image artifacts from eFOV reconstruction with a wide-bore CT scanner in radiotherapy (RT) treatment planning. Methods: Testing phantoms (i.e., a mini CT phantom with equivalent tissue inserts, a set of CT normal phantoms and anthropomorphic phantoms of the thorax and the pelvis) were used to evaluate eFOV artifacts. Reference baseline images of these phantoms were acquired with the phantom centrally positioned within the sFOV. For comparison, the phantoms were then shifted laterally and scanned partially outside the sFOV, but still within the eFOV. Treatment plans were generated for the thoracic and pelvic anthropomorphic phantoms utilizing the Eclipse treatment planning system (TPS) to study the potential effects of eFOV artifacts on dose calculations. All dose calculations of baseline and test treatment plans were carried out using the same MU. Results: Results show that both body contour and CT numbers are altered by image artifacts in eFOV reconstruction. CT number distortions of up to -356 HU for bone tissue and up to 323 HU for lung tissue were observed in the mini CT phantom. Results from the large body normal phantom, which is close to a clinical patient size, show average CT number changes of up to -49 HU. Wider distribution (i.e., standard deviation) of the HU values was seen when the phantom was placed at more than 2.8 cm beyond the 50 cm sFOV. Anthropomorphic phantom studies with several standard beam configurations show that body contour distortion causes tumor dose calculation reduction of 3.0 and 1.9% for 6 and 23 MV x-rays, respectively, when not accounting for tissue heterogeneities during dose computation. When heterogeneity correction is used in planning, the competing effects of the body contour distortion and the CT number distortion cause a smaller error in tumor dose calculation. Less than 0.9% error in calculated dose was observed in volumetric modulated arc therapy (VMAT) treatment plans. Conclusions: The image artifacts from eFOV reconstruction alter the CT numbers and body contours of the imaged objects, which has the potential to produce inaccuracies in dose calculations during radiotherapy treatment planning. The radiation therapy team should be aware of these image artifacts and their effects on target dose calculations during CT simulation as well as treatment planning.

61 RADIATION PROTECTION AND DOSIMETRY↗

Fractal analysis for assessing the level of modulation of IMRT fields

Purpose: To investigate the potential of three fractal dimension (FD) analysis methods (i.e., the variation, power spectrum, and variogram methods) as metrics for quantifying the degree of modulation in planned intensity modulated radiation therapy (IMRT) treatment fields, and compare the most suitable FD method to the number of monitor units (MUs), the average leaf gap, and the 2D modulation index (2D MI) for assessing modulation. Methods: The authors implemented, validated, and compared the variation, power spectrum, and variogram methods for computing the FD. Validation of the methods was done using mathematical fractional Brownian surfaces of known FD that ranged in size from 128 x 128 to 512 x 512. The authors used a test set consisting of seven head and neck carcinoma plans (50 prescribed treatment fields) to choose an FD cut-point that ensures no false positives (100% specificity) in distinguishing between moderate and high degrees of field modulation. The degree of field modulation was controlled by adjusting the fluence smoothing parameters in the Eclipse treatment planning system (Varian Medical Systems, Palo Alto, CA). The moderate modulation fields were representative of the degree of modulation used clinically at the authors' institution. The authors performed IMRT quality assurance (QA) on the 50 test fields using the MapCHECK device. The FD cut-point was applied to a validation set consisting of four head and neck plans (28 fields). The area under the curve (AUC) from receiver operating characteristic (ROC) analysis was used to compare the ability of FD, number of MUs, average leaf gap, and the 2D MI for distinguishing between the moderate and high modulation fields. Results: The authors found the variogram FD method to be the most suitable for assessing the modulation complexity of IMRT fields for head and neck carcinomas. Pass rates as measured by the gamma criterion for the MapCHECK IMRT field measurements were higher for the moderately modulated fields, and a gamma criterion with 1 mm distance-to-agreement and 1% dose difference showed a clear separation between the 94% pass rates of the moderate and high modulation groups. From the ROC analysis of the test set, the authors found the AUC of the variogram FD, number of MUs, average leaf gap, and 2D MI methods to be 0.99 (almost perfect), 0.91 (excellent), 0.91 (excellent), and 0.92 (excellent), respectively. A cut-point of FD > 2.25 correctly identified 92.8% of the high modulation fields and 100% of the moderately modulated fields in the validation set, satisfying the condition of no false positives. Conclusions: Of the three FD methods investigated, the variogram method is the most accurate and precise metric for identifying high modulation treatment fields. It is also more accurate and precise than the number of MUs, the average leaf gap, and the 2D MI. Although MapCHECK IMRT QA does a reasonable job at identifying high modulation fields, the variogram FD method provides one with the opportunity to quantitatively and accurately assess modulation and adjust overly modulated fields at the treatment planning stage before they are sent to the treatment machine for QA or patient treatment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-J-138: An IGRT QA Device for Measuring with Tenths-Millimeter Accuracy KV and MV Isocenter Congruence, Couch Travel and Laser Alignment of Accelerators Used for SRS and SBRT

Purpose: To develop a practical device having sufficient accuracy for daily QA tests of accelerators used for SRS and SBRT. Methods: The UAB (Universal Alignment Ball) consists of a 6.35 mm (1/4 inch) diameter tungsten sphere located concentrically within a 25.4 mm (1 inch) diameter acrylic plastic (PMMA) sphere. The spheres are embedded in polystyrene foam, which, in turn, is surrounded by a cylindrical PMMA shell. The UAB is placed on the couch and aligned with wall lasers according to marks that have known positions in relation to the center of the spheres. Using planar and cone beam images the couch is shifted till the surface of the PMMA sphere matches Eclipse-generated circular contours. Anterior and lateral MV images taken with small MLC openings allow measurement of distance between kV and MV isocenter, laser and MLC alignment. Measurements were taken over a one-month period. Results: Artifacts from the tungsten sphere were confined within the PMMA sphere and did not affect cone beam localization of the sphere boundary, allowing 0.1 mm precise alignment with a computer-generated circle centered at kV isocenter. In tests extending over a one-month period, the distance between kV and MV isocenters along the vertical, longitudinal and lateral directions was 0.125 +/−0.06, 0.19 +/−0.08, and 0.02 +/−0.08 mm, respectively. Laser misalignment along these directions was 0.34 +/- 0.15, 0.74 +/−0.29, and 0.49 +/−0.22 mm. Automated couch shifts moved the spheres to within 0.1 mm of the selected position. The center of a 1cmx1cm MLC-defined field remained within +/−0.2 mm of the tungsten sphere center as the gantry was rotated. Conclusion: The UAB is practical for daily end-to-end QA tests of accelerator alignment. It provides tenths-mm accuracy for measuring agreement of kV and MV isocenters, couch motions, gantry flex and laser alignment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Spatial variation of dosimetric leaf gap and its impact on dose delivery

Purpose: During dose calculation, the Eclipse treatment planning system (TPS) retracts the multileaf collimator (MLC) leaf positions by half of the dosimetric leaf gap (DLG) value (measured at central axis) for all leaf positions in a dynamic MLC plan to accurately model the rounded leaf ends. The aim of this study is to map the variation of DLG along the travel path of each MLC leaf pair and quantify how this variation impacts delivered dose. Methods: 6 MV DLG values were measured for all MLC leaf pairs in increments of 1.0 cm (from the line intersecting the CAX and perpendicular to MLC motion) to 13.0 cm off axis distance at dmax. The measurements were performed on two Varian linear accelerators, both employing the Millennium 120-leaf MLCs. The measurements were performed at several locations in the beam with both a Sun Nuclear MapCHECK device and a PTW pinpoint ion chamber. Results: The measured DLGs for the middle 40 MLC leaf pairs (each 0.5 cm width) at positions along a line through the CAX and perpendicular to MLC leaf travel direction were very similar, varying maximally by only 0.2 mm. The outer 20 MLC leaf pairs (each 1.0 cm width) have much lower DLG values, about 0.3–0.5 mm lower than the central MLC leaf pair, at their respective central line position. Overall, the mean and the maximum variation between the 0.5 cm width leaves and the 1.0 cm width leaf pairs are 0.32 and 0.65 mm, respectively. Conclusions: The spatial variation in DLG is caused by the variation of intraleaf transmission through MLC leaves. Fluences centered on the CAX would not be affected since DLG does not vary; but any fluences residing significantly off axis with narrow sweeping leaves may exhibit significant dose differences. This is due to the fact that there are differences in DLG between the true DLG exhibited by the 1.0 cm width outer leaves and the constant DLG value utilized by the TPS for dose calculation. Since there are large differences in DLG between the 0.5 cm width leaf pairs and 1.0 cm width leaf pairs, there is a need to correct the TPS plans, especially those with high modulation (narrow dynamic MLC gap), with 2D variation of DLG.

60 APPLIED LIFE SCIENCES↗

SU-E-T-111: An Iterative Approach to Modelling Dosimetric Properties of a Varian MLC

Purpose: In effort to efficiently and accurately model MLC parameters for use in Varian Eclipse treatment planning system (TPS), an iterative technique for characterizing the dosimetric properties of MLCs has been developed. Methods: The initial characterization of the dosimetric leaf gap (DLG) and MLC transmission was performed using varied sizes of moving gaps and transmission measurements through central axis of the radiation beam. These values were determined during the initial data collection. After the initial values were determined and entered into the TPS, two plans were calculated to test the veracity of DLG and transmission independently. The plan used to determine the DLG has openings of varied sizes which are affected differently by the DLG. A large field uniform fluence that required a MLC carriage shift was used to determine the transmission value independent of DLG. After characterizing the dosimetric properties of the MLC independently, clinical IMRT plans were tested and used to tweak the final values. Results: This approach to modelling MLC dosimetric properties was employed for: standard 120 leaf MLC (SDMLC) and 120 leaf high definition MLC (HDMLC). Both types were successfully commissioned, tested, and approved for clinical use on 4 SDMLC machines and 2 HDMLC machines. The pass rate of clinical IMRT plans was 96.9% for 6MV and 98.3% for 10MV for SDMLC and 96.3% for 6MV, 96.5% for 6FFF, and 97.5% for 10FFF for HDMLCs using MapCheck2 with gamma analysis of 2%/2mm and 10% threshold. The final DLG and transmission parameters for 6X were 0.5mm and 0.01, and 1.35mm and 0.02 for HD and SD MLCs respectively. Conclusion: This iterative approach of determining dosimetric properties of MLCs is viable for both SDMLC and HDMLC and multiple energies. This approach accurately and efficiently determines the values needed for commissioning MLCs when they are employed for modulated therapies.

60 APPLIED LIFE SCIENCES↗

SU-E-T-163: Characterization of a Novel High Resolution 1D Silicon Monolithic Array for Small Field Commissioning and Quality Assurance

Purpose: To study the suitability of a novel 1D silicon monolithic array for dosimetry of small radiation fields and for QA of high dose gradient treatment modalities (IMRT and SBRT). Methods: A 1D array composed of 4 monolithic silicon modules of 64 mm length and 1 mm pixel pitch was developed by IBA Dosimetry. Measurements were carried out for 6MV and 15MV photons on two commercial different linacs (TrueBeam and Clinac iX, Varian Medical Systems, Palo Alto, CA) and for a CyberKnife G4 (Accuray Inc., Sunnyvale, CA). The 1D array was used to measure output factors (OF), profiles and off axis correction factors (OACF) for the Iris CyberKnife variable collimator (5–60 mm). In addition, dose profiles (at the isocenter plane) were measured for multiple IMRT and SBRT treatment plans and compared with those obtained using EDR2radiographic film (Carestream Health, Rochester NY), a commercial 2D diode array and with the dose distribution calculated using a commercial TPS (Eclipse, Varian Medical Systems, Palo Alto, CA). Results: Due to the small pixel pitch of the detector, IMRT and SBRT plan profiles deviate from film measurements by less than 2%. Similarly, the 1D array exhibits better performance than the 2D diode array due to the larger (7 mm) pitch of that device. Iris collimator OFs measured using the 1D silicon array are in good agreement with the commissioning values obtained using a commercial stereotactic diode as well as with published data. Maximum deviations are < 3% for the smallest field (5 and 7.5mm) and below 1% for all other dimensions. Conclusion: We have demonstrated good performances of the array for commissioning of small photon fields and in patient QA, compared with diodes and film typically used in these clinical applications. The technology compares favorably with existing commercial solutions The presenting author is founded by a Marie Curie Early Initial Training Network Fellowship of the European Communitys Seventh Framework Programme under contract number (PITN-GA-2011-289198-ARDENT). The research activity is hosted by IBA Dosimetry, Gmbh.

60 APPLIED LIFE SCIENCES↗

SU-E-T-181: Clinical Implementation of Task Group 176

Purpose: The implementation of TG-176 with regards to immobilization devices and couch tops as they effect dosimetric treatment planning. Methods: The external devices used clinically were scanned to measure their HU values. Plans were created in the Eclipse treatment planning system (TPS) using these devices, one that accounted for the correct HU value of the each device and another that did not include the device as a structure. A dose subtraction was performed between the two plans to evaluate the dosimetric differences. The metrics used for evaluation included attenuation and surface dose. Plan parameters were varied to evaluate the impact of the devices in different clinical scenarios. Results: While the exact HU values of our results are clinic-dependent, the protocol being implemented is widely applicable. We recommend a four step process for implementing this task group. First, physics should scan each treatment device to determine accurate HU values. Second, CT therapists should include in the setup note which table top was used during patient CT simulation and are asked to make immobilization devices as uniform in thickness as possible. Therapists should also index the devices whenever possible so beam will traverse the same area of the device. Third, the dosimetrist should manually correct the HU value for any external device, including the couch. For H&N cases, the rails must be removed from the couch structure. When rails are used during treatments, it is important to make note of their exact position in the setup notes. Finally, physicians should be made aware that there could be changes in surface doses depending on whether or not immobilization devices or couch tops are in the beam path. Conclusion: The protocol outlined above was implemented to reduce the errors that arise from ignoring effects of external devices, thus ensuring safer, more accurate patient treatments.

60 APPLIED LIFE SCIENCES↗

THE FIRST PHOTOMETRIC ANALYSES OF THE ALGOL BINARY SYSTEMS GSC 04328-02164 AND GSC 03164-01558

The CCD observations for the eclipsing Algol type binary systems GSC 04328-02164 in wideband BVR{sub c}I{sub c} filters and GSC 03164-01558 in B and I filters have been analyzed using the PHOEBE package (v 0.31a) to determine their orbital and physical parameters. The absolute parameters and evolutionary tracks of the two systems have been determined. The results show that the mass ratio, inclination, distance, and age for the system GSC 04328-02164 are equal to q = 0.674 ± 0.002, i = 75.997 ± 0.022, d = 375.477 ± 4.299 pc, and τ = 26.76 ± 15.65 ∗ 10{sup 8} years, respectively. For the other system, GSC 03164-01558, q = 0.941 ± 0.006, i = 88.0484 ± 0.030, d = 444.651 ± 9.444 pc, and τ = 53.63 ± 9.16 ∗ 10{sup 8} years.

79 ASTRONOMY AND ASTROPHYSICS↗

SEEING THROUGH THE RING: NEAR-INFRARED PHOTOMETRY OF V582 MON (KH 15D)

We examine the light and color evolution of the T Tauri binary KH 15D through photometry obtained at wavelengths between 0.55 and 8.0 μm. The data were collected with A Novel Dual Imaging CAMera (ANDICAM) on the 1.3 m SMARTS telescope at Cerro-Tololo Inter-American Observatory and with InfraRed Array Camera on the Spitzer Space Telescope. We show that the system’s circumbinary ring, which acts as a screen that covers and uncovers different portions of the binary orbit as the ring precesses, has reached an orientation where the brighter component (star B) fully or nearly fully emerges during each orbital cycle. The fainter component (star A) remains fully occulted by the screen at all phases. The leading and trailing edges of the screen move across the sky at the same rate of ∼15 m s{sup −1}, consistent with expectation for a ring with a radius and width of ∼4 au and a precession period of ∼6500 years. Light and color variations continue to indicate that the screen is sharp edged and opaque at VRIJH wavelengths. However, we find an increasing transparency of the ring edge at 2.2, 3.6, and 4.5 μm. Reddening seen at the beginning of the eclipse that occurred during the CSI 2264 campaign particularly suggests selective extinction by a population of large dust grains. Meanwhile, the gradual bluing observed while star B is setting is indicative of forward scattering effects at the edge of the ring. The spectral energy distribution of the system at its bright phase shows no evidence of infrared excess emission that can be attributed to radiation from the ring or other dust component out to 8 μm.

79 ASTRONOMY AND ASTROPHYSICS↗

NEAR-CONTACT BINARIES IZ MONOCEROTIS AND AR DRACONIS

We present multi-color photometric observations for two neglected near-contact binaries, IZ Mon (P=0--AMP--fd;77980) and AR Dra (P=0--AMP--fd;67584). By the aid of the updated W-D analysis code, the photometric solutions were deduced from the multi-color light curves (LCs). IZ Mon is a semi-detached binary with a mass ratio of q=0.388(±0.002), while AR Dra is a detached star with a mass ratio of q=0.652(±0.002). The asymmetric LCs of IZ Mon were modeled by a hot spot on the secondary’s surface, which may be attributed to mass transfer from the primary. Based on all collected eclipse times for two systems, we constructed their timing residual curves. The orbital period for IZ Mon may be continuously decreasing at a rate of dP/dt=−2.06(±0.04) days yr{sup −1}, which may result from mass and angular momentum loss from the central system. For AR Dra, there exists a cyclic variation with a period of P{sub 3}=104.9(±2.9) yr due to light-time orbit effect via the presence of the third body, whose mass is more than 0.28(±0.02) M{sub ⊙}. Finally, two near-contact binaries, IZ Mon and AR Dra, will evolve into contact binaries.

79 ASTRONOMY AND ASTROPHYSICS↗

KELT-14b AND KELT-15b: AN INDEPENDENT DISCOVERY OF WASP-122b AND A NEW HOT JUPITER

We report the discovery of KELT-14b and KELT-15b, two hot Jupiters from the KELT-South survey. KELT-14b, an independent discovery of the recently announced WASP-122b, is an inflated Jupiter mass planet that orbits a ~5.0{sub -0.7}{sup +0.3} Gyr, V = 11.0, G2 star that is near the main sequence turnoff. The host star, KELT-14 (TYC 7638-981-1), has an inferred mass M{sub &middot;} = 1.18{sub -0.07}{sup +0.05} M{sub ⊙} and radius R{sub &middot;} = 1.37±-0.08 R{sub ⊙}, and has T{sub eff} = 5802{sub -92}{sup +95} K, logg{sub &middot;} = 4.23{sub -0.04}{sup +0.05} and [Fe/H] = 0.33 ± -0.09. The planet orbits with a period of 1.7100588 ± 0.0000025 days (T{sub 0} = 2457091.02863 ± 0.00047) and has a radius R{sub p} = 1.52{sub -0.11}{sup +0.12} R{sub J} and mass M{sub p} = 1.196 ± 0.072 M{sub J}, and the eccentricity is consistent with zero. KELT-15b is another inflated Jupiter mass planet that orbits a ~4.6{sub -0.4}{sup +0.5} Gyr, V = 11.2, G0 star (TYC 8146-86-1) that is near the “blue hook” stage of evolution prior to the Hertzsprung gap, and has an inferred mass M{sub &middot;} = 1.181{sub -0.050}{sup +0.051} M{sub ⊙} and radius R{sub &middot;} = 1.48{sub -0.04}{sup +0.09} R{sub ⊙}, and T{sub eff} = 6003{sub -52}{sup +56} K, logg{sub &middot;} = 4.17{sub -0.04}{sup +0.02} and [Fe/H] = 0.05 ± 0.03. The planet orbits on a period of 3.329441 ± 0.000016 days (T{sub 0} = 2457029.1663 ± 0.0073) and has a radius R{sub p} = 1.443{sub -0.057}{sup +0.11} R{sub J} and mass M{sub p} = 0.91{sub -0.22}{sup +0.21} M{sub J} and an eccentricity consistent with zero. KELT-14b has the second largest expected emission signal in the K-band for known transiting planets brighter than K < 10.5. Both KELT-14b and KELT-15b are predicted to have large enough emission signals that their secondary eclipses should be detectable using ground-based observatories.

79 ASTRONOMY AND ASTROPHYSICS↗

STARSPOTS ON WASP-85

By analyzing K2 short-cadence observations, we detect starspots on WASP-85A, the host star of the hot Jupiter WASP-85Ab. The detection of recurring starspot occultation events indicates that the planet’s orbit is aligned with the star’s rotational axis (λ<14°) and suggests a stellar rotational period of 15.1 ± 0.6 days. The K2 light curve reveals a rotational modulation with a period of 13.6 ± 1.6 days, which is consistent with the period determined from starspots. There are no significant transit-timing variations, and thus no evidence of any additional planet in the system. Given the pronounced rotational modulation, we are only able to place an upper limit of 100 parts per million for any phase-curve modulations and the secondary eclipse.

79 ASTRONOMY AND ASTROPHYSICS↗

MULTI-FILTER LIGHT CURVES OF 29 VERY SHORT PERIOD CANDIDATE CONTACT BINARIES

Light curves of 26 probable contact binary stars are made available, from a list of candidates with the shortest periods known. This is supplemented by sets of light curves of three previously studied systems. Photometry was obtained in the Johnson UBV, Cousins RI system. All stars but one were observed in four wavebands, either UBV R{sub C} or BV(RI){sub C}, depending on brightness. Tentative spectral classifications are given for 23 of the stars. Effective temperatures are derived from infrared and optical photometric indices, and from spectral types. These are generally in good agreement. The multicolor photometry, spectral typing, and estimated effective temperatures can be used to model these systems in detail. A preliminary study, based on Fourier coefficients of the light curves, suggests that all the systems are indeed eclipsing stars, with all but a handful probably in contact configurations.

79 ASTRONOMY AND ASTROPHYSICS↗

CATACLYSMIC VARIABLES OBSERVED DURING K2 CAMPAIGNS 0 AND 1

There are 15 cataclysmic variables (CVs) observed in the first two campaigns of the K2 mission. In this paper, the eight CVs showing distinct features are analyzed in detail. Among these eight, modulations during quiescence are evident at the known orbital periods in the SU UMa stars QZ Vir and RZ Leo, and at our newly determined orbital periods for 1RXS J0632+2536 and WD 1144+011. The periodogram analysis for the quiescent light curve of QZ Vir reveals multi-period modulations and the coexistence of orbital and superhump periods. The phased orbital light curves for the other three CVs in quiescence display wide (about half cycle) and shallow (<0.5 mag) eclipse features. Besides these modulations, their quiescent light curves reveal several transient events: a sudden decrease of system light in 1RXS J0632+2536, a low-level flare-like event in QZ Vir, a short brightening event in RZ Leo, and a temporary disappearance of the orbital modulation in WD 1144+011. The two known dwarf novae UV Gem and TW Vir and the CVs USNO-B1.01144-00115322 and CSS 130516:111236:111236.7+002807 show outbursts, including one complete and three incomplete normal outbursts and two complete superoutbursts. An incomplete but typical normal outburst confirms the dwarf nova identification of the USNO-B1.01144-00115322. The one complete normal outburst in UV Gem may provide the orbital period, since its modulations are shorter than the previously observed superhump period. The superoutburst of CSS 130516:111236.7+002807, along with the corresponding superhump period, indicates that this object is an SU UMa star. The derived superhump period of CSS 130516:111236:111236.7+002807 is 1.44 hr, implying that this new SU UMa star is close to the period minimum.

79 ASTRONOMY AND ASTROPHYSICS↗

PHOTOMETRIC, SPECTROSCOPIC, AND ORBITAL PERIOD STUDY OF THREE EARLY-TYPE SEMI-DETACHED SYSTEMS: XZ AQL, UX HER, AND AT PEG

In this paper, we present a combined photometric, spectroscopic, and orbital period study of three early-type eclipsing binary systems: XZ Aql, UX Her, and AT Peg. As a result, we have derived the absolute parameters of their components and, on that basis, we discuss their evolutionary states. Furthermore, we compare their parameters with those of other binary systems and with theoretical models. An analysis of all available up-to-date times of minima indicated that all three systems studied here show cyclic orbital changes; their origin is discussed in detail. Finally, we performed a frequency analysis for possible pulsational behavior, and as a result we suggest that XZ Aql hosts a δ Scuti component.

79 ASTRONOMY AND ASTROPHYSICS↗

BINARY CENTRAL STARS OF PLANETARY NEBULAE DISCOVERED THROUGH PHOTOMETRIC VARIABILITY. IV. THE CENTRAL STARS OF HaTr 4 AND Hf 2-2

We explore the photometrically variable central stars of the planetary nebulae HaTr 4 and Hf 2-2. Both have been classified as close binary star systems previously based on their light curves alone. Here, we present additional arguments and data confirming the identification of both as close binaries with an irradiated cool companion to the hot central star. We include updated light curves, orbital periods, and preliminary binary modeling for both systems. We also identify for the first time the central star of HaTr 4 as an eclipsing binary. Neither system has been well studied in the past, but we utilize the small amount of existing data to limit possible binary parameters, including system inclination. These parameters are then compared to nebular parameters to further our knowledge of the relationship between binary central stars of planetary nebulae and nebular shaping and ejection.

79 ASTRONOMY AND ASTROPHYSICS↗

THE B AND Be STATES OF THE STAR EM CEPHEUS

We present 11 yr of high-resolution, spectroscopic observations for the star EM Cep. EM Cep switches between B and Be star states, as revealed by the level of Hα emission, but spends most of its time in the B star state. EM Cep has been considered to be an eclipsing, near-contact binary of nearly equal-mass B stars in order to reproduce regular photometric variations; however, this model is problematic due to the lack of any observed Doppler shift in the spectrum. Our observations confirm that there are no apparent Doppler shifts in the wide spectral lines Hα and He i λ6678 in either the B or Be star states. The profiles of He i λ6678 typically exhibited a filled-in absorption core, but we detected weak emission in this line during the highest Be state. Given the lack of observed Doppler shifts, we model EM Cep as an isolated Be star with a variable circumstellar disk. We can reproduce the observed Hα emission profiles over the 11 yr period reasonably well with disk masses on the order of 3--10× 10{sup −11} M{sub ∗} in the Be state with the circumstellar disk seen at an inclination of 78° to the line of sight. From a disk ejection episode in 2014, we estimate a mass-loss rate of ≈3×10{sup −9} M{sub ⊙} yr{sup −1}. The derived disk density parameters are typical of those found for the classical Be stars. We therefore suggest that the EM Cep is a classical Be star and that its photometric variations are the result of β Cep or nonradial pulsations.

79 ASTRONOMY AND ASTROPHYSICS↗