Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “drill”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 865 records · Page 48

Completion Report for Well ER-EC-11 Corrective Action Units 101 and 102: Central and Western Pahute Mesa

Well ER-EC-11 was drilled for the U.S. Department of Energy, National Nuclear Security Administration Nevada Site Office, in support of the Nevada Environmental Restoration Project at the Nevada National Security Site (formerly Nevada Test Site), Nye County, Nevada. The well was drilled in September and October 2009 as part of the Pahute Mesa Phase II drilling program. A main objective was to investigate radionuclide migration down-gradient from Well Cluster ER-20-5 and Well ER-20-7 and across the northern Timber Mountain moat structural zone into the area referred to as the Bench, between Pahute Mesa and the Timber Mountain caldera complex. A secondary purpose of the well was to provide detailed hydrogeologic information for the shallow- to intermediate-depth Tertiary volcanic section in the Bench area. This well also provided detailed hydrogeologic information in the Tertiary volcanic section to reduce uncertainties within the Pahute Mesa-Oasis Valley hydrostratigraphic framework model (Bechtel Nevada, 2002). The main 52.1-centimeter hole was drilled to a depth of 507.5 meters and then opened to a diameter of 66.0 centimeters. It was cased with 50.8-centimeter casing to 504.9 meters. The hole diameter was then decreased to 47.0 centimeters, and drilling continued to a total depth of 979.3 meters. It was then cased with 34.0-centimeter casing set at 965.5 meters. The hole diameter was then decreased to 31.1 centimeters and the borehole was drilled to a total depth of 1,264.3 meters. The completion casing string, set to the depth of 1,262.5 meters, consists of 19.4-centimeter stainless-steel casing hanging from 19.4-centimeter carbon-steel casing. The stainless-steel casing has two slotted intervals open to the Tiva Canyon and Topopah Spring aquifers. Four piezometer strings were installed in Well ER-EC-11. A string of carbon-steel 6.0-centimeter tubing with one slotted interval was inserted outside the 50.8-centimeter casing, within the 66.0-centimeter borehole for access to the Timber Mountain aquifer, and landed at 475.3 meters. A second string of 6.0-centimeter tubing with one slotted interval was inserted outside the 34.0-centimeter casing, within the 47.0-centimeter borehole for access to the Benham aquifer, and landed at 911.7 meters. A third piezometer string consists of 7.3-centimeter stainless-steel tubing that hangs from 6.0-centimeter carbon-steel tubing via a crossover sub. This string was landed at 1,029.5 meters to monitor the Tiva Canyon aquifer. The deepest string of 7.3-centimeter tubing was landed at 1,247.8 meters to monitor the Topopah Spring aquifer. Data collected during and shortly after hole construction include composite drill cuttings samples collected every 3.0 meters, 67 percussion gun and rotary sidewall core samples, various geophysical logs, fluid samples (for groundwater chemistry analysis and tritium measurements), and water-level measurements. The well penetrated 1,264.3 meters of Tertiary volcanic rock, including three saturated welded-tuff aquifers and one saturated lava-flow aquifer. A water level was measured in the Timber Mountain aquifer at 449.6 meters, during open-hole geophysical logging on September 20, 2009. The fluid level measured after the total depth was reached and the upper aquifer was cased off was 450.0 meters when measured in the open borehole on October 17, 2009. Measurements on samples taken from the undeveloped well indicated that tritium levels averaging approximately 12,430 picocuries per liter (less than Safe Drinking Water Act levels) were encountered within the Benham aquifer. Tritium was below the minimum detectable activity concentration for samples collected from the Tiva Canyon aquifer and the Topopah Spring aquifer.

54 ENVIRONMENTAL SCIENCES↗

Preliminary Hydrogeologic Characterization Results from the Wallula Basalt Pilot Study

The DOE's Big Sky Regional Carbon Sequestration Partnership has completed drilling the first continental flood basalt sequestration pilot borehole to a total depth (TD) of 4,110 feet on the Boise White Paper Mill property at Wallula, Washington. Site suitability was assessed prior to drilling by the 2007-2008 acquisition, processing and analysis of a four-mile, five-line three component seismic swath, which was processed as a single data-dense line. Analysis of the seismic survey data indicated a composite basalt formation thickness of {approx}8,000 feet and absence of major geologic structures (i.e., faults) along the line imaged by the seismic swath. Drilling of Wallula pilot borehole was initiated on January 13, 2009 and reached TD on April 6, 2009. Based on characterization results obtained during drilling, three basalt breccia zones were identified between the depth interval of 2,716 and 2,910 feet, as being suitable injection reservoir for a subsequent CO2 injection pilot study. The targeted injection reservoir lies stratigraphically below the massive Umtanum Member of the Grande Ronde Basalt, whose flow-interior section possesses regionally recognized low-permeability characteristics. The identified composite injection zone reservoir provides a unique and attractive opportunity to scientifically study the reservoir behavior of three inter-connected reservoir intervals below primary and secondary caprock confining zones. Drill cuttings, wireline geophysical logs, and 31one-inch diameter rotary sidewall cores provided geologic data for characterization of rock properties. XRF analyses of selected rock samples provided geochemical characterizations of the rocks and stratigraphic control for the basalt flows encountered by the Wallula pilot borehole. Based on the geochemical results, the pilot borehole was terminated in the Wapshilla Ridge 1 flow of the Grande Ronde Basalt Formation. Detailed hydrologic test characterizations of 12 basalt interflow reservoir zones and 3 flow-interior/caprock intervals were performed during drilling and immediately following reaching the final borehole drilling depth (i.e., 4,110 ft). In addition, six of the 12 basalt interflow zones were selected for detailed hydrochemical characterization. Results from the detailed hydrologic test characterization program provided the primary information on basalt interflow zone transmissivity/injectivity, and caprock permeability characteristics.

58 GEOSCIENCES↗

Development of a High Pressure/High Temperature Down-hole Turbine Generator

As oil & natural gas deposits become more difficult to obtain by conventional means, wells must extend to deeper more heat-intensive environments. The technology of the drilling equipment required to reach these depths has exceeded the availability of electrical power sources needed to operate these tools. Historically, logging while drilling (LWD) and measure while drilling (MWD) devices utilized a wireline to supply power and communication from the operator to the tool. Lithium ion batteries were used in scenarios where a wireline was not an option, as it complicated operations. In current downhole applications, lithium ion battery (LIB) packs are the primary source for electrical power. LIB technology has been proven to supply reliable downhole power at temperatures up to 175 °C. Many of the deeper well s reach ambient temperatures above 200 °C, creating an environment too harsh for current LIB technology. Other downfalls of LIB technology are cost, limitations on charge cycles, disposal issues and possible safety hazards including explosions and fires. Downhole power generation can also be achieved by utilizing drilling fluid flow and converting it to rotational motion. This rotational motion can be harnessed to spin magnets around a series of windings to produce power proportional to the rpm experienced by the driven assembly. These generators are, in most instances, driven by turbine blades or moyno-based drilling fluid pumps. To date, no commercially available downhole power generators are capable of operating at ambient temperatures of 250 °C. A downhole power g enerator capable of operation in a 250 °C and 20,000 psi ambient environment will be an absolute necessity in the future. Dexter Magnetic Technologies’ High-Pressure High-Temperature (HPHT) Downhole Turbine Generator is capable of operating at 250 °C and 20, 000 psi, but has not been tested in an actual drilling application. The technology exists, but to date no company has been willing to test the tool.

03 NATURAL GAS↗

Completion Report for Well ER-20-11, Corrective Action Units 101 and 102: Central and Western Pahute Mesa

Well ER-20-11 was drilled for the U.S. Department of Energy, National Nuclear Security Administration Nevada Site Office in support of the Nevada Environmental Management Operations Underground Test Area (UGTA) Activity at the Nevada National Security Site (formerly Nevada Test Site), Nye County, Nevada. The well was drilled in September 2012 as part of the Central and Western Pahute Mesa Corrective Action Unit Phase II drilling program. Well ER-20-11 was constructed to further investigate the nature and extent of radionuclide-contaminated groundwater encountered in two nearby UGTA wells, to help define hydraulic and transport parameters for the contaminated Benham aquifer, and to provide data for the UGTA hydrostratigraphic framework model. The 44.5-centimeter (cm) surface hole was drilled to a depth of 520.0 meters (m) and cased with 34.0-cm casing to 511.5 m. The hole diameter was then decreased to 31.1 cm, and the borehole was drilled to a total depth of 915.6 m. The hole was completed to allow access for hydrologic testing and sampling in the target aquifer, which is a lava-flow aquifer known as the Benham aquifer. The completion casing string, set to the depth of 904.3 m, consists of a string of 6 5/8-inch (in.) stainless-steel casing hanging from a string of 7 5/8-in. carbon-steel casing. The stainless-steel casing has one slotted interval at 796.3 to 903.6 m. One piezometer string was installed, which consists of 2 7/8-in. stainless-steel tubing that hangs from 2 3/8-in. carbon-steel tubing via a crossover sub. This string was landed at 903.8 m and is slotted in the interval 795.3 to 903.1 m. Data collected during and shortly after hole construction include composite drill cuttings samples collected every 3.0 m, various geophysical logs, fluid samples (for groundwater chemistry analysis and tritium measurements), and water-level measurements. The well penetrated 915.6 m of Tertiary volcanic rock, including one saturated lava flow aquifer. Measurements on samples taken from the undeveloped well indicated elevated tritium levels within the Benham aquifer. The maximum tritium level measured with field equipment was 146,131 picocuries per liter from a sample obtained at the depth of 912.0 m. The fluid level was measured in the piezometer string at a depth of 504.5 m on September 26, 2012. All Fluid Management Plan (FMP) requirements for Well ER-20-11 were met. Analysis of monitoring samples and FMP confirmatory samples indicated that fluids generated during drilling at Well ER-20-11 met the FMP criteria for discharge to an unlined sump or designated infiltration area. Well development, hydrologic testing, and sampling will be conducted at a later date.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Completion Report for Well ER-2-2 Corrective Action Unit 97: Yucca Flat/Climax Mine, Revision 1

Well ER-2-2 was drilled for the U.S. Department of Energy, Nevada National Security Administration Nevada Field Office in support of the Underground Test Area (UGTA) Activity. The well was drilled from January 17 to February 8, 2016, as part of the Corrective Action Investigation Plan (CAIP) for Corrective Action Unit 97: Yucca Flat/Climax Mine, Nevada Test Site, Nevada. The primary purpose of the well was to collect hydrogeologic data to evaluate uncertainty in the flow and transport conceptual model and its contamination boundary forecasts, and to detect radionuclides in groundwater from the CALABASH (U2av) underground test. Well ER-2-2 was not completed as planned due to borehole stability problems. As completed, the well includes a piezometer (p1) to 582 meters (m) (1,909 feet [ft]) below ground surface (bgs) installed in the Timber Mountain lower vitric-tuff aquifer (TMLVTA) and a 12.25-inch (in.) diameter open borehole to 836 m (2,743 ft) bgs in the Lower tuff confining unit (LTCU). A 13.375-in. diameter carbon-steel casing is installed from the surface to a depth of 607 m (1,990 ft) bgs. Data collected during borehole construction include composite drill cutting samples collected every 3.0 m (10 ft), geophysical logs to a depth of 672.4 m (2,206 ft) bgs, water-quality measurements (including tritium), water-level measurements, and slug test data. The well penetrated 384.05 m (1,260 ft) of Quaternary alluvium, 541.93 m (1,778 ft) of Tertiary Volcanics (Tv) rocks, and 127.71 m (419 ft) of Paleozoic carbonates. The stratigraphy and lithology were generally as expected. However, several of the stratigraphic units were significantly thicker then predicted—principally, the Tunnel formation (Tn), which had been predicted to be 30 m (100 ft) thick; the actual thickness of this unit was 268.22 m (880 ft). Fluid depths were measured in the borehole during drilling as follows: (1) in the piezometer (p1) at 552.15 m (1,811.53 ft) bgs and (2) in the main casing (m1) at 551.69 m (1,810.01 ft) bgs. As expected, field measurements for tritium were above the Safe Drinking Water Act limit (20,000 picocuries per liter) for a portion of the Tertiary volcanic section near the water table. Tritium concentrations were at or near the field detection limit in the Lower carbonate aquifer (LCA) while drilling. During drilling, a sample was collected while circulating in the LCA. The sample was submitted for off-site laboratory analysis. The sample results indicated low but measurable tritium concentrations. All Fluid Management Plan requirements were met during drilling activities.

54 ENVIRONMENTAL SCIENCES↗

FY2022 Progress Report for Advanced Re-fabrication/Re-instrumentation Capability Development

In support of performing follow-on irradiation experiments with previously irradiated materials, the Halden Reactor Project developed unique and state of the art capabilities to refabricate and re-instrument previously irradiated materials. Such materials were used in in-pile tests at the Halden reactor, and out-of-pile tests for example using furnaces as a heat source. The decision to close the Halden Reactor Project results in the loss of this refabrication and re-instrumentation capability. As a result, the United States (U.S.) Department of Energy (DOE) has determined to develop refabrication and re-instrumentation capability at the unique shielded facilities at Idaho National Laboratory (INL). The development of refabrication capability has been completed and demonstrated. This report focuses on the complementary aspects of reinstrumentation and the progress to-date. Halden spent nearly 30 years developing both refabrication and re-instrumentation. Collaboration with Halden is allowing Idaho National Laboratory (INL) to develop this capability much more rapidly. In FY-21 the results include development of the capability to drill annular center holes in ceramic UO2 fuel pellets, development of fuel rod end caps with feedthroughs for centerline instrumentation inside the rodlet, The procurement of both fuel drilling and welding demonstration equipment from Halden, evaluation of surface thermocouple attachments to support better understanding of temperature measurement uncertainties, and finally, the conceptual design of a new shielded enclosure where advanced refabrication and re-instrumentation equipment can be housed. In FY-22, the results include; Completing set up of the drilling and welding modules procured from Halden, and early experimental trials using that equipment.; Completing set up of an out-of-cell circumferential weld system to allow for further weld development to take place and support fabrication of fuel for fresh fuel experiments.; Evaluation of the Hot Fuel Examination Facility (HFEF) infrastructure to support future installation of advanced re-fabrication/re-instrumentation equipment, specifically related to necessary infrastructure for cryo-drilling.; Developments in dry-drilling alternative. Including experimental studies showing cordierite is the most suitable surrogate for UO 2 for performing drilling studies. That drilling performance is enhanced when a fuel-clad bonding condition is simulated.; Conceptual design completed for attaching surface thermocouples to irradiated fuel in support of TWIST capsule experiments. The authors would like to thank the numerous colleagues at INL and Halden who provided support in accomplishing this work. Their support both material and intellectual is invaluable in advancing the state of the art and establishing the capabilities for refabrication and re-instrumentation at INL.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Mitigation for Removal of Building 01-202681 in the Main Storage Yard of the Area 1 Subdock, Nevada National Security Site, Nye County, Nevada

The Main Storage Yard was originally recorded as SHPO Resource No. S2772 in 2020 during an architectural survey of the Area 1 Subdock (Collins et al. 2022). It was recommended individually eligible for listing in the NRHP under Criteria A and C and as contributing to the significance of the potential Area 1 Subdock Historic District. The SHPO concurred with these determinations in a letter dated April 29, 2022 (Reed). The Main Storage Yard retains all seven aspects of integrity. The location, design, materials, workmanship, feeling, and association have not changed since the original construction. Since the purpose of the yard is to maintain storage equipment that is actively being used, the design and feeling will change each time equipment is moved. Such actions reinforce the integrity of design and feeling. Buildings 01-101 and 01-102 were removed (Collins and Menocal 2020), but the other buildings and storage yard remain. Therefore, the setting has been changed, but not to the degree that the Main Storage Yard no longer conveys its significance (see Figures 4 and 5 for comparison). The Main Storage Yard was designed to facilitate the relocation of the Area 3 Subdock to Area 1 in 1985. The design for the overall Subdock provided a centralized cluster of buildings surrounded by two large storage yards. While the North Storage Yard largely serves as overflow storage, the Main Storage Yard holds the majority of drill rigs and drilling equipment needed to support big hole drilling. The Main Storage Yard and its contents were essential elements of the nuclear testing drilling program on the NNSS thus making it eligible for the NRHP under Criterion A for its contribution to broad patterns of history by storing specially designed equipment for underground nuclear testing at the NNSS. It is also eligible under Criterion C as it is an engineered landscape that now serves as an open-air repository of drilling technology and nuclear testing. In addition to its individual significance, the Main Storage Yard also contributes to the significance of the Area 1 Subdock Historic District as it showcases a variety of big-hole drilling equipment, support facilities, and warehouses that were specially designed for nuclear testing at the NNSS. Despite the demolition of two contributing elements to date, the district still contains numerous examples of other facilities with the purpose of supporting big-hole drilling; therefore, the district still remains eligible under Criteria A and C.

54 ENVIRONMENTAL SCIENCES↗

Leveraging Regional Exploration to Develop Geologic Framework for CO2 Storage in Deep Formations in Midwestern United States

Obtaining subsurface data for developing a regional framework for geologic storage of CO{sub 2} can require drilling and characterization in a large number of deep wells, especially in areas with limited pre-existing data. One approach for achieving this objective, without the prohibitive costs of drilling costly standalone test wells, is to collaborate with the oil and gas drilling efforts in a piggyback approach that can provide substantial cost savings and help fill data gaps in areas that may not otherwise get characterized. This leveraging with oil/gas drilling also mitigates some of the risk involved in standalone wells. This collaborative approach has been used for characterizing in a number of locations in the midwestern USA between 2005 and 2009 with funding from U.S. Department of Energy's National Energy Technology Laboratory (DOE award: DE-FC26-05NT42434) and in-kind contributions from a number of oil and gas operators. The results are presented in this final technical report. In addition to data collected under current award, selected data from related projects such as the Midwestern Regional Carbon Sequestration Partnership (MRCSP), the Ohio River Valley CO{sub 2} storage project at and near the Mountaineer Plant, and the drilling of the Ohio Stratigraphic well in Eastern Ohio are discussed and used in the report. Data from this effort are also being incorporated into the MRCSP geologic mapping. The project activities were organized into tracking and evaluation of characterization opportunities; participation in the incremental drilling, basic and advanced logging in selected wells; and data analysis and reporting. Although a large number of opportunities were identified and evaluated, only a small subset was carried into the field stage. Typical selection factors included reaching an acceptable agreement with the operator, drilling and logging risks, and extent of pre-existing data near the candidate wells. The region of study is primarily along the Ohio River Valley corridor in the Appalachian Basin, which underlies large concentrations of CO{sub 2} emission sources. In addition, some wells in the Michigan basin are included. Assessment of the geologic and petrophysical properties of zones of interest has been conducted. Although a large number of formations have been evaluated across the geologic column, the primary focus has been on evaluating the Cambrian sandstones (Mt. Simon, Rose Run, Kerbel) and carbonates layers (Knox Dolomite) as well as on the Silurian-Devonian carbonates (Bass Island, Salina) and sandstones (Clinton, Oriskany, Berea). Factors controlling the development of porosity and permeability, such as the depositional setting have been explored. In northern Michigan the Bass Islands Dolomite appears to have favorable reservoir development. In west central Michigan the St. Peter sandstone exhibits excellent porosity in the Hart and Feuring well and looks promising. In Southeastern Kentucky in the Appalachian Basin, the Batten and Baird well provided valuable data on sequestration potential in organic shales through adsorption. In central and eastern Ohio and western West Virginia, the majority of the wells provided an insight to the complex geologic framework of the relatively little known Precambrian through Silurian potential injection targets. Although valuable data was acquired and a number of critical data gaps were filled through this effort, there are still many challenges ahead and questions that need answered. The lateral extent to which favorable potential injection conditions exist in most reservoirs is still generally uncertain. The prolongation of the characterization of regional geologic framework through partnership would continue to build confidence and greatly benefit the overall CO{sub 2} sequestration effort.

54 ENVIRONMENTAL SCIENCES↗

Self-advancing step-tap tool

Methods and tool for simultaneously forming a bore in a work piece and forming a series of threads in said bore. In an embodiment, the tool has a predetermined axial length, a proximal end, and a distal end, said tool comprising: a shank located at said proximal end; a pilot drill portion located at said distal end; and a mill portion intermediately disposed between said shank and said pilot drill portion. The mill portion is comprised of at least two drill-tap sections of predetermined axial lengths and at least one transition section of predetermined axial length, wherein each of said at least one transition section is sandwiched between a distinct set of two of said at least two drill-tap sections. The at least two drill-tap sections are formed of one or more drill-tap cutting teeth spirally increasing along said at least two drill-tap sections, wherein said tool is self-advanced in said work piece along said formed threads, and wherein said tool simultaneously forms said bore and said series of threads along a substantially similar longitudinal axis.

Pettit, Donald R.↗

Foldable Instrumented Bits for Ultrasonic/Sonic Penetrators

Long tool bits are undergoing development that can be stowed compactly until used as rock- or ground-penetrating probes actuated by ultrasonic/sonic mechanisms. These bits are designed to be folded or rolled into compact form for transport to exploration sites, where they are to be connected to their ultrasonic/ sonic actuation mechanisms and unfolded or unrolled to their full lengths for penetrating ground or rock to relatively large depths. These bits can be designed to acquire rock or soil samples and/or to be equipped with sensors for measuring properties of rock or soil in situ. These bits can also be designed to be withdrawn from the ground, restowed, and transported for reuse at different exploration sites. Apparatuses based on the concept of a probe actuated by an ultrasonic/sonic mechanism have been described in numerous prior NASA Tech Briefs articles, the most recent and relevant being "Ultrasonic/ Sonic Impacting Penetrators" (NPO-41666) NASA Tech Briefs, Vol. 32, No. 4 (April 2008), page 58. All of those apparatuses are variations on the basic theme of the earliest ones, denoted ultrasonic/sonic drill corers (USDCs). To recapitulate: An apparatus of this type includes a lightweight, low-power, piezoelectrically driven actuator in which ultrasonic and sonic vibrations are generated and coupled to a tool bit. The combination of ultrasonic and sonic vibrations gives rise to a hammering action (and a resulting chiseling action at the tip of the tool bit) that is more effective for drilling than is the microhammering action of ultrasonic vibrations alone. The hammering and chiseling actions are so effective that the size of the axial force needed to make the tool bit advance into soil, rock, or another material of interest is much smaller than in ordinary twist drilling, ordinary hammering, or ordinary steady pushing. Examples of properties that could be measured by use of an instrumented tool bit include electrical conductivity, permittivity, magnetic field, magnetic permeability, temperature, and any other properties that can be measured by fiber-optic sensors. The problem of instrumenting a probe of this type is simplified, relative to the problem of attaching electrodes in a rotating drill bit, in two ways: (1) Unlike a rotating drill bit, a bit of this type does not have flutes, which would compound the problem of ensuring contact between sensors and the side wall of a hole; and (2) there is no need for slip rings for electrical contact between sensor electronic circuitry and external circuitry because, unlike a rotating drill, a tool bit of this type is not rotated continuously during operation. One design for a tool bit of the present type is a segmented bit with a segmented, hinged support structure (see figure). The bit and its ultrasonic/sonic actuator are supported by a slider/guiding fixture, and its displacement and preload are controlled by a motor. For deployment from the folded configuration, a spring-loaded mechanism rotates the lower segment about the hinges, causing the lower segment to become axially aligned with the upper segment. A latching mechanism then locks the segments of the bit and the corresponding segments of the slider/guiding fixture. Then the entire resulting assembly is maneuvered into position for drilling into the ground. Another design provides for a bit comprising multiple tubular segments with an inner alignment string, similar to a foldable tent pole comprising multiple tubular segments with an inner elastic cable connecting the two ends. At the beginning of deployment, all segments except the first (lowermost) one remain folded, and the ultrasonic/sonic actuator is clamped to the top of the lowermost segment and used to drive this segment into the ground. When the first segment has penetrated to a specified depth, the second segment is connected to the upper end of the first segment to form a longer rigid tubular bit and the actuator is moved to the upper end of the second segnt. The process as described thus far is repeated, adding segments until the desired depth of penetration has been attained. Yet other designs provide for bits in the form of bistable circular- or rectangular- cross-section tubes that can be stowed compactly like rolls of flat tape and become rigidified upon extension to full length, in a manner partly similar to that of a common steel tape measure. Albeit not marketed for use in tool bits, a bistable reeled composite product that transforms itself from a flat coil to a rigid tube of circular cross section when unrolled, is commercially available under the trade name RolaTube(TradeMark) and serves as a model for the further development of tool bits of this subtype.

Bar-Cohen, Yoseph↗

Techno-Economic Performance of Eavor Loop 2.0

This project evaluated techno-economic performance for a sample Eavor-Loop 2.0 design for electricity production and direct-use heating. The Eavor-Loop 2.0 design investigated is a 7.5-km deep closed-loop geothermal system consisting of 12 laterals for a total of more than 90 km of downhole well and lateral length. Both a high geothermal gradient scenario of 60 degrees C/km and a low geothermal gradient scenario of 30 degrees C/km were considered. With pure water injected at 60 degrees C and 80 kg/s, reservoir simulations with the Slender-Body Theory simulator indicate average production temperatures over a 30-year lifetime of ~125 degrees C and ~210 degrees C for the low and high geothermal gradient scenario, respectively. These correspond to heat production of ~22 M Wth and ~51 M Wth, respectively. Using IPSEpro simulations, we find average power production of ~2.2 M We and ~8.6 M We, respectively, for a subcritical organic Rankine cycle power plant with air-cooled condensers. Cost estimates indicate the overall capital and levelized costs are dominated by the lateral drilling cost. Obtaining a levelized cost of electricity below $70/M Wh requires a geothermal gradient of 60 degrees C/km, a discount rate below 9%, and lateral drilling cost below $400/m. A well cost model indicates that ~$400/m for the Eavor-Loop 2.0 design investigated can be obtained for a drilling rate of penetration about 40 ft/hr (with bit life of 50 hours), and omitting casing and cement. Traditional (geothermal) well drilling has achieved these drilling rate conditions, including the Utah FORGE project where the rate of penetration has exceeded 50 ft/hr in granite. However, it is unclear if these conditions are still valid for drilling the Eavor-Loop 2.0 laterals (i.e., ~82 km of laterals at 4 to 7.5-km vertical depth with rock temperatures up to 460 degrees C), as such downhole completion has never been developed before. Competitive levelized cost of heat values ($1.2-$8.2/GJ) are calculated, even for the low geothermal gradient scenario (30 degrees C/km) and lateral drilling cost of $600/m.

advanced geothermal system↗

Approach to Recover Hydrocarbons from Currently Off-Limit Areas of the Antrim Formation, MI Using Low-Impact Technologies

The goal of this project was to develop and execute a novel drilling and completion program in the Antrim Shale near the western shoreline of Northern Michigan. The target was the gas in the Lower Antrim Formation (Upper Devonian). Another goal was to see if drilling permits could be obtained from the Michigan DNR that would allow exploitation of reserves currently off-limits to exploration. This project met both of these goals: the DNR (Michigan Department of Natural Resources) issued permits that allow drilling the shallow subsurface for exploration and production. This project obtained drilling permits for the original demonstration well AG-A-MING 4-12 HD (API: 21-009-58153-0000) and AG-A-MING 4-12 HD1 (API: 21-009-58153-0100) as well as for similar Antrim wells in Benzie County, MI, the Colfax 3-28 HD and nearby Colfax 2-28 HD which were substituted for the AG-A-MING well. This project also developed successful techniques and strategies for producing the shallow gas. In addition to the project demonstration well over 20 wells have been drilled to date into the shallow Antrim as a result of this project's findings. Further, fracture stimulation has proven to be a vital step in improving the deliverability of wells to deem them commercial. Our initial plan was very simple; the 'J-well' design. We proposed to drill a vertical or slant well 30.48 meters (100 feet) below the glacial drift, set required casing, then angle back up to tap the resource lying between the base to the drift and the conventional vertical well. The 'J'-well design was tested at Mancelona Township in Antrim County in February of 2007 with the St. Mancelona 2-12 HD 3.

04 OIL SHALES AND TAR SANDS↗

Completion Report for Well ER-20-7: Corrective Action Units 101 and 102: Central and Western Pahute Mesa

Well ER-20-7 was drilled for the U.S. Department of Energy, National Nuclear Security Administration Nevada Site Office in support of the Nevada Environmental Restoration Project at the Nevada Test Site, Nye County, Nevada. The well was drilled in June 2009 as part of the Pahute Mesa Phase II drilling program. The primary purpose of the well was to further investigate migration of radionuclides from the nearby, up-gradient TYBO and BENHAM underground nuclear tests, which originally was discovered at Well Cluster ER-20-5. This well also provided detailed hydrogeologic information in the Tertiary volcanic section that will reduce uncertainties within the Pahute Mesa-Oasis Valley hydrostratigraphic framework model. The main 44.45-centimeter hole was drilled to a depth of 681.8 meters and cased with 33.97-centimeter casing to 671.7 meters. The hole diameter was then decreased to 31.12 centimeters, and the well was drilled to total depth of 894.9 meters. The completion string, set to the depth of 890.0 meters, consists of 14.13-centimeter stainless-steel casing hanging from 19.37-centimeter carbon-steel casing. The 14.13-centimeter stainless-steel casing has one continuous slotted interval open to the Topopah Spring aquifer. Data collected during and shortly after hole construction include composite drill cuttings samples collected every 3.0 meters, sidewall core samples from 20 depth intervals, various geophysical logs, water quality (primarily tritium) measurements, and water level measurements. The well penetrated 894.9 meters of Tertiary volcanic rock, including two saturated welded-tuff aquifers. A fluid level measurement was obtained during open-hole geophysical well logging for the upper, Tiva Canyon, aquifer at the depth of 615.7 meters on June 19, 2009. The fluid level measured in the open hole on June 27, 2009,after the total depth was reached and the upper aquifer was cased off, was also at the depth of 615.7 meters. Preliminary field measurements indicated 1.5 to 4.5 million picocuries per liter of tritium in the Tiva Canyon aquifer and 20 to 61 million picocuries per liter in the underlying Topopah Spring aquifer.

54 ENVIRONMENTAL SCIENCES↗

Reservoir Characterization and Techno-Economic Analysis of Enhanced Geothermal and Closed-Loop Systems in the Wattenberg Field of the Denver-Julesburg Basin, Colorado

This report provides details of reservoir characterization and techno-economic analysis for enhanced geothermal systems and closed-loop geothermal systems in the Denver-Julesburg Basin Wattenberg area. The analysis contributes to the Geothermal Limitless Approach to Drilling Efficiencies (GLADE) project, a multi-institutional research initiative focused on advancing geothermal energy development by reducing drilling costs and improving the rate of penetration. The GLADE project brings together national laboratories, academic institutions, and industry partners, including the U.S. Department of Energy's Geothermal Technologies Office, Occidental Petroleum, the National Laboratory of the Rockies (NLR), Los Alamos National Laboratory, Colorado School of Mines, Louisiana State University, Texas A&M University, and several drilling technology companies. As part of this effort, NLR developed and applied slender-body theory modeling tools and the GEOPHIRES simulator to support techno-economic analysis. The slender-body theory wellbore simulator evaluated thermal performance in U-loop, Eavor-type multilateral, and enhanced geothermal system well configurations. Results indicated that an optimized single U-loop design delivers an outlet temperature of 168.8 degrees Celsius,stabilizing at a final outlet temperature of 135.3 degrees Celsius. Heat production also improved significantly, with an average thermal output of 16.9 MWth and a final thermal output of 11.0 MWth. These results provided critical baseline data for selecting optimized systems for techno-economic analysis. Building on these outputs, NLR applied the GEOPHIRES techno-economic simulator to estimate the levelized cost of electricity for both the Eavor multilateral and enhanced geothermal systems. The sensitivity analysis showed that drilling costs exert a particularly strong impact on the levelized cost of electricity of multilateral systems. Therefore, advances in drilling technology and improved drilling rates could yield significant gains in the economic performance of these systems. In this context, the GLADE project directly supports the U.S. Department of Energy's mission to reduce the cost of geothermal energy and accelerate the deployment of next-generation geothermal technologies.

15 GEOTHERMAL ENERGY↗

Resonance excitation of surface capillary waves to enhance material removal for laser material processing

Abstract The results of detailed experiments and high fidelity modeling of melt pool dynamics, droplet ejections and hole drilling produced by periodic modulation of laser intensity are presented. Ultra-high speed imaging revealed that melt pool oscillations can drive large removal of material when excited at the natural oscillation frequency. The physics of capillary surface wave excitation is discussed and simulation is provided to elucidate the experimental results. The removal rates and drill through times as a function of driving frequency is investigated. The resonant removal mechanism is driven by both recoil momentum and thermocapillary force but the key observation is the latter effect does not require evaporation of material, which can significantly enhance the efficiency for laser drilling process. We compared the drilling of holes through a 2 mm-thick Al plate at modulation frequencies up to 20 kHz. At the optimal frequency of 8 kHz, near the resonant response of the melt pool, the drilling efficiency is greater than 10x with aspect ratio of 12:1, and without the collateral damage that is observed in unmodulated CW drilling.

47 OTHER INSTRUMENTATION↗

Volcanic stratigraphy and age model of the Kimama deep borehole (Project Hotspot): Evidence for 5.8 million years of continuous basalt volcanism, central Snake River Plain, Idaho

The Snake River Plain of central Idaho represents the world’s best example of a mantle hotspot track impinging upon continental crust and provides a record of bimodal volcanism extending over 12 Ma to the present. Project Hotspot recovered almost 2 km of continuous drill core from the Kimama borehole, located in central Idaho on the axial volcanic zone. The Kimama drill core represents the most complete record of mafic volcanism along the Yellowstone–Snake River Plain hotspot track. A total of 432 basalt flow units, representing 183 basalt flows, 78 basalt flow groups, and 34 super groups, along with 42 sediment interbeds are recognized using volcanic facies observations, stratigraphic relationships, borehole geophysical logs, and paleosecular variation in magnetostratigraphy. Rhyolite and other non-basaltic volcanic materials were not encountered in the drill core. Ages for six basalt lava flows were determined by 40 Ar/ 39 Ar using incremental heating experiments. Paleomagnetic inclination was measured on over 1200 samples collected at roughly 2-m-depth intervals, yielding mean values of paleosecular variation between ±50° to ±70° in Kimama flow groups, close to the expected 61° axial dipole average for the Kimama borehole location. Twenty-three magnetic reversals were identified and correlated to dated geomagnetic chrons and subchrons and compared with the 40 Ar/ 39 Ar radiometric ages. A linear fit to 40 Ar/ 39 Ar dates, geomagnetic chron and subchron boundaries, and volcanogenic zircon U-Pb ages defines a mean accumulation rate of ~320 m/m.y. and extrapolates to a bottom hole age of 6.3 Ma. Average thicknesses of lithologic units increase from 2.7 m (sediment), 4 m (flow units), 10 m (flows), 23 m (flow groups), to 53 m (super groups). On average, one lava flow inundated the Kimama borehole location every 33 k.y. Intercalated sediments, ranging from 0.06 to 24.5 m thick, make up roughly 6% of the drill core and indicate lulls in local volcanic activity that may have lasted up to 77 k.y. Neutron and gamma-ray logs supplement observations from the drill cores: neutron logs document individual flow units through the contrast between massive flow interiors and more porous flow surfaces, and gamma-ray logs document the depth and thickness of sedimentary interbeds and high–K-Fe basalts. The 5.8 m.y. duration of basaltic volcanism in the Kimama drill core implies a steady rate of volcanism, indicating a relatively stable rate of mantle upflow along the lithosphere-mantle boundary in the wake of Yellowstone–Snake River Plain plume volcanism.

58 GEOSCIENCES↗

Kick Detection at the Bit: Early Detection via Low Cost Monitoring

Formation fluid influxes (i.e. kicks) pose persistent challenges and operational costs during drilling operations. Implications of kicks range in scale but cumulatively result in substantial costs that affect drilling safety, environment, schedule, and infrastructure. Early kick detection presents a low-cost, easily adopted solution for avoiding well control challenges associated with kicks near the bit. Borehole geophysical tools used during the drilling process as part of the logging-while-drilling (LWD) and measurement-while-drilling (MWD) provide the advantage of offering real-time downhole data. LWD/MWD collect data on both the annulus and borehole wall. The annular data are normally treated as background, and are filtered out to isolate the formation measurements. Because kicks will change the local physical properties of annular fluids, bottom-hole measurements are among the first indicators that a formation fluid has invaded the wellbore. This report describes and validates a technique for using the annular portion of LWD/MWD data to facilitate early kick detection using first order principles. The detection technique leverages data from standard and cost-effective technologies that are typically implemented during well drilling, such as MWD/LWD data in combination with mud-pulse telemetry for data transmission.

42 ENGINEERING↗

Play Fairway Analysis: Structurally Controlled Geothermal Systems in the Eastern Great Basin Extensional Regime, Utah

A research team with membership from the University of Utah/Energy & Geoscience Institute, the University of Utah/Dept. of Geology & Geophysics, and the Utah Geological Survey, undertook a play fairway analysis (PFA) for geothermal resources in the Eastern Great Basin (EGB) extensional tectonic regime of western Utah. This is a high-priority region for geothermal exploration because active Basin and Range (B&R) extension with volcanism having a N-S strike is superimposed upon pre-existing E-W belts of plutonic rocks and large-scale structural lineaments. Cumulative heat flow along the N-S strike of the state totals approximately 5 GWt above background stable interior. Three electricity producing power plants currently exist with substantial potential for increase. Succinctly, our PFA approach aims to resolve potential sources of heat and permeability in the region, which are the two principal criteria for establishing a geothermal resource. An initial Phase 1 was carried out using only existing geoscientific data in the area. Criteria selected for focusing heat potential include direct heat flow measurements in boreholes, magnetotelluric (MT) low resistivity anomalies, fluid/gas geochemistry, and proximity to recent volcanic eruptions. Permeability is established through geological structures (fault density, critically stressed areas, seismicity, gravity), and MT low resistivity anomalies. In Phase II of this PFA project, additional geological, geophysical and geochemical data were acquired and analysis carried out primarily over promising composite common risk (CCR) areas initially identified in Phase I in order to focus prospectivity and prepare for drilling recommendations. These prospects are near the Twin Peaks rhyolite field, high heat flow areas north of the producing Cove Fort system, and geophysical structure beneath the Crater Knoll area off the northeast flank of the Mineral Mountains. Additional data included MT site fill-in, structural mapping and analysis using high-resolution imagery, gravity and on-ground mapping, Nodal 3C passive seismic collection, and passive 3He surveying. Heat source and permeability potential are again expressed in terms of their individual common risk segment (CRS) maps, with a color scheme using green for most favorable (low risk) and red for least favorable (high risk). Diverse data types are united through the technique of probability kriging, which establishes prospectivity thresholds for each data type and then computes probability of exceeding that threshold over the PFA area. Modified CRS and CCRS maps are compared to those of Phase I to highlight tighter prospectivity focus. In doing so, the prospectivity threshold for heat was increased significantly to narrow the targeting. In the final Phase III of this project where a recommended deep thermal gradient hole was sited, additional geophysical, geochemical and geological field collection and analysis was carried out to refine drill hole targeting. This includes prospect-scale MT, gravity, structure, passive seismic deployment (Cove Fort area), and detailed 3He isotope profiling. It was the recommendation of the DOE Technical Monitoring Team (TMT) that one or more holes be sited in the north-ern Cove Fort area where legacy TG gradient holes showed high cumulative heat flow. These were to be of moderate depth, 2000-3000 feet, to reach the geothermal fluid table expected to start in excess of 1000 feet depth. The drilling organization stipulated by the DOE/GTO was that of the USGS Research Drilling Program (RDP) centered in Las Vegas, NV. A detailed well plan, appended to this report, was developed principally by Dr. Ben Barker consulting to University of Utah, Dr. Steve Pye on the DOE TMT, Mr. Steven Crawford of the USGS-RDP, and the project PI Phil Wannamaker. However, temperature and possible H 2 S at the systems lead to cancellation of the drilling last-minute as this appeared outside the experience base of the USGS-RDP. We hope to have the opportunity to revisit the test drilling and expand the Play Fairway Analysis of this region at some point in the future.

15 GEOTHERMAL ENERGY↗