Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “distribution system planning”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 865 records · Page 48

Stabilizing the Power System in 2035 and Beyond: Evolving from Grid-Following to Grid-Forming Distributed Inverter Controllers (Final Technical Report)

Under existing grid operations, large synchronous generators provide sufficient rotational inertia to form a rigid backbone for the bulk power system. With photovoltaics (PV) forecasted to provide more than 600 GW of generation by 2050 under the U.S. Department of Energy’s SunShot Initiative objectives, however, it is clear that power electronic inverters will play a dominant role in future systems, and low-inertia stability must be ensured to maintain system reliability. Today, the risks to system stability can be observed on geographically small islands, such as Hawaii, which contain a relatively large amount of installed PV. These risks stem from a fundamental shortcoming of contemporary control strategies—existing inverter controllers cannot guarantee grid stability. Given that future power systems driven by sustainable resources will be characterized by low inertia, locations such as Hawaii provide a glimpse into the obstacles facing future power systems. Considering these challenges, the aim of this project was to develop and demonstrate distributed inverter controllers that enable the reliable control of low-inertia power systems with hundreds of gigawatts of integrated PV.

14 SOLAR ENERGY↗

Holistic Transportation and Energy Modeling

This project advances the development and application of the TEMPO transportation energy systems model to support DOE analysis of evolving mobility futures. Recent work has focused on improving model transparency, performance, and fidelity through a redesigned software architecture and updated technology adoption scenarios aligned with the latest data and assumptions. Ongoing efforts aim to expand TEMPO's ability to assess transportation affordability and consumer decision-making, including vehicle ownership dynamics and distributional impacts across households. These enhancements position TEMPO to better inform policy and R&D decisions by providing more behaviorally realistic and policy-relevant insights into transportation energy use, technology adoption, and system-level outcomes.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Assessing the Technical Potential of Fast Frequency Response in Grid-Supportive Loads

Fast frequency response (FFR) is a critical tool for grid operators to manage contingency events in low-inertia systems. While large generators and loads are more commonly used, many smaller end use loads, in aggregate, can provide FFR across a large system. This work considers the technical potential of power electronics-based loads for autonomous FFR in low-inertia grids. We consider multiple factors that might influence the impact of FFR for various end use loads, with a focus on residential loads.

ENERGY PLANNING, POLICY, AND ECONOMY,POWER TRANSMI↗

Hydrogen Leak Modeling for Development of Smart Distributed Monitoring Under Unintended Releases

Hydrogen is a versatile and clean energy carrier that can be produced from various renewable sources such as wind, solar, and hydropower. Hydrogen has the potential to play a crucial role in decarbonizing industrial processes that are currently reliant on fossil fuels and provide long-duration and/or seasonal energy storage to enable electricity decarbonization. Hydrogen can also be used as a fuel for fuel cell vehicles, providing a zero-emission alternative to traditional internal combustion engines. DOE launched the Hydrogen Energy Earthshot (Hydrogen Shot) in June 2021 to reduce the cost of clean hydrogen by 80% to $1 per 1 kilogram in 1 decade ("1 1 1"). While promising, Hydrogen is highly-flammable, and in the presence of oxygen, it can form explosive mixtures. . Therefore, understanding leak scenarios is essential to evaluate and mitigate the safety risks associated with potential hydrogen leaks. An increased understanding of leak behavior, and having tools to model leaks, can help assess how hydrogen would disperse in different environments, influencing emergency response plans and safety measures, and identify potential issues with materials and design systems that can withstand the challenges posed by hydrogen. Recently, researchers have attempted to study hydrogen leaks for development of risk management strategies. However, the focus has been on closed or semi-closed spaces like storage rooms, vehicles, garages, and fueling stations - all promising locations for future hydrogen infrastructure. In this presentation, the modeling environment extends the span of research further by modeling hydrogen leak in an outdoor, open space. We will present the key challenges with modeling hydrogen leaks in an uncontrollable environment, how they were handled, and how modeling results informed sensor selection and placement. A Hydrogen research facility at the National Renewable Energy Laboratory (NREL) was used as a case study to model hydrogen leaks. In the future, Hydrogen wide area detection methodologies will be developed and tested at this site to monitor for unintended and operational hydrogen releases. The data generated from modeling will be used to develop a predictive model to detect hydrogen leak location based on concentration measured by sensors in this open space. Furthermore, the facility was also chosen because controlled hydrogen releases can be performed. A computational fluid dynamics (CFD) based modeling approach was taken to model hydrogen leak. The full-scale hydrogen facility was modeled with a large ambient domain. The electrolyzer at the facility can produce a controlled release rate of 27 kg-H2/hr. Site-specific atmospheric and weather condition data such as wind direction, wind speed at various altitudes, and temperature were used as inputs to the model. To capture the variability of weather conditions, a subset of the weather conditions experienced during daytime hours without precipitation over the course of three months was generated; using established data clustering techniques, a total of 100 condition sets were chosen. The results show statistical distributions and ranges of hydrogen concentrations at locations throughout the domain. These distributions are compared to experimental data from a constant mass flow, controlled hydrogen release at the facility. The stochastic wind conditions of the release make direct validation difficult, therefore, statistical comparison approaches were used. Wind conditions are found to significantly impact the release behavior, including direction and concentration. Sensor selection and placement is proposed for the facility and is now based on release behavior predicted for the facility given its weather patterns; this is much more informed than without the modeling results. The methodology and analysis procedure can be translated to other facilities using modified geometries and site-specific weather conditions. Hydrogen holds great promise as a renewable energy fuel, but ensuring safety in its production, storage, and use is paramount. Studying potential leak scenarios in an open space will help develop sensors to detect hydrogen on a large spectrum of concentration and eventually build a smart distributed monitoring system.

CFD↗

Power Supply Options for the Marpi Landfill, Saipan: Addendum to 2023 Feasibility Study

The Marpi Landfill (Marpi or the landfill), located on the northern end of the island of Saipan in the Commonwealth of the Northern Mariana Islands (CNMI), is powered by an on-site diesel generator that only operates when the landfill is open and staffed. The CNMI Office of Planning and Development (OPD) aspires to provide the Marpi Landfill with 24-hour power availability despite its remote location and to increase sustainable energy consumption within the CNMI. Pacific Northwest National Laboratory (PNNL) authored a feasibility study in 2023 that explores alternative power supply options for the landfill. This feasibility study (hereafter referred to as Phase I of this study) culminated in a report named “Power Supply Options for the Marpi Landfill, Saipan.” In Phase I, the project team investigated and prioritized seven different power supply scenarios (Table ES-1) for the landfill according to Solid Waste (SW) Taskforce priorities. The project team found that Scenario 4 (100 kW of solar photovoltaic [PV] generation, a 75 kW/300 kWh battery energy storage system [BESS], and 160 kW of diesel generation) ranked highest. Following the Phase I feasibility study, the SW Taskforce secured additional funding for PNNL to assess additional considerations regarding power supply options for Marpi. The purpose of Phase II of this study is to investigate these additional considerations, as compiled in this addendum. Some of the findings compiled here replace findings from the original report. The project team evaluated additional considerations regarding power supply options for the landfill, including modified operations to account for 24/7 power supply, electrified landfill equipment, new and replacement distribution line costs, and the social cost of carbon.

14 SOLAR ENERGY↗

The past, present, and future of peaking thermal power plants in the United States

Today's power systems rely on "peaker plants" to reliably serve load during peak demand periods. In this study we consider the present competitiveness of different peaking options, how much and what kinds of plants have provided U.S. peaking capacity, and potential future peaking fleet compositions. We explore how capital intensity impacts the breakeven capacity factor between two potential resources: combustion turbines (CTs) and combined cycle plants (CCs). CTs outcompete CCs below 12%-17% annual capacity factor at today's prices, but can shift with changes to fuel or start costs. Historically, gas CTs and petroleum steam plants most closely fit the role of peakers. Peaking capacity could grow from approximately 280 GW today to 460-770 GW in 2050 composed of a wider range of resources. We conclude by discussing implications of this shift, with a focus on the potential planning considerations for shifting to a greater utilization of CCs for peaking needs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Guanajuato Policy Options for Land Transportation Greenhouse Gas Reduction [Slides]

NREL consulted the Mexican state of Guanajuato to help them identify and prioritize policies that are specifically applicable to their land transportation system and help them meet their greenhouse gas (GHG) reduction goals. Three focus groups were held across Guanajuato to get the input from a wide variety of users of the transportation system. These focus groups performed a SWOT (strengths, weaknesses, opportunities and threats) analysis of Guanajuato's transportation system and logged the policy goals of participants. NREL then developed a menu of policy options that have been used successfully in relevant countries and prioritized these policies based on the weighted input from stakeholder groups. The most applicable policies were a paid parking strategy, regional transit master plan, and expanded bike and pedestrian infrastructure. Case studies of these three policies, plus a few more, were then presented to inform Guanajuato of how these policies could successfully be implemented. Finally, the GHG reductions for five of the most applicable policies were estimated to reduce emissions from Guanajuato's land transportation system nearly 40% below business-as-usual emissions by 2050.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Optimizing DER Deployment for Climate, Health, Resilience, and Energy Bill Benefits Using the REopt Model

Climate change, public health, and resilience to power outages are of critical concern to local governments, federal agencies, and the private sector, and are increasingly motivating investments in distributed energy resources (DERs). However, designing a solar-plus-storage system to co-optimize for climate, health, resilience, and energy bill benefits requires complex trade-offs. To address this need, the National Renewable Energy Laboratory has integrated climate and health impacts of grid-purchased electricity and on-site fuel consumption into the publicly-available REopt web tool and API - a techno-economic model that determines the cost-optimal DER system sizes and dispatch strategy. This presentation will provide an overview of the tool's methodology, datasets, and capabilities, including costing emissions into system sizing and dispatch and setting emissions reductions targets. Results of previous work will demonstrate the use of new emissions accounting capabilities by quantifying the impact of including climate and health costs on the optimal resilient microgrid configurations for a hospital, school, and warehouse across 14 U.S. cities.

climate↗

REopt Lite Overview & Training Exercise

This training exercise provides users with an introduction to and hands-on, interactive exploration of REopt Lite's capabilities. REopt Lite is a free, publicly available techno-economic optimization web tool for distributed energy systems, developed at the National Renewable Energy Laboratory (NREL). REopt Lite helps organizations evaluate the economic viability of grid-connected solar photovoltaics (PV), wind turbines, and battery storage; identify system sizes and battery dispatch strategies to minimize energy costs; and estimate how long a system can sustain critical load during a grid outage. The model is formulated as a mixed-integer linear program based in an underlying application programming interface (API) that is also free and publicly available. This training activity is structured as a group exercise. Participants split into eight groups and each group is assigned a different hypothetical site to model and assess the opportunity for solar PV + battery storage. Groups work together to develop results for their site and then re-convene to compare and discuss results, inputs/drivers of the analysis, and other factors impacting the decision-making process for behind-the-meter solar PV and battery storage.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Cybersecurity in Photovoltaic Plant Operations

This paper provides practical information for PV plant operators regarding cybersecurity. Plans to integrate photovoltaic generation into utility systems requires that cybersecurity be considered in every aspect- from customer data to business information to plant monitoring and control operations. This paper describes the types of threats encountered in operation of PV plants; challenges faced by photovoltaic plant operators in implementing cybersecurity; cybersecurity standards that apply to photovoltaic plant operations; cybersecurity response plans and recommended best practices to ensure photovoltaic plant cybersecurity.

14 SOLAR ENERGY↗

Powering Up Secure and Reliable Operations at the Port of Honolulu's Kapalama Container Terminal

The National Laboratory of the Rockies (NLR) is providing resilience planning support to the Pasha Group, the operator of Kapalama Container Terminal (KCT) at the Port of Honolulu, by exploring how distributed clean energy resources could help the terminal sustain a 36-hour outage and continue emergency operations. The Department of Energy's Energy Transitions Initiative (ETI) aims to advance self-reliant island and remote communities by promoting resilient, affordable, and sustainable clean energy resources.

25 ENERGY STORAGE↗

SERAPH: Wavelike Dark Matter Searches with SRF Cavities

Haloscopes consisting of a microwave cavity with a high quality factor (Q) connected to low-noise electronics have been deployed to detect wavelike axions and dark photons. But the dark matter mass is unknown, so haloscopes must be tunable to search through the photon coupling vs. mass parameter space. Therefore, the scan rate for haloscope experiments is a crucial figure of merit and is proportional to the cavity’s quality factor. State-of-the-art experiments like ADMX currently use copper cavities with 𝑄∼80000. However, implementing superconducting cavities with 𝑄∼1010 can increase the instantaneous scan rate by possibly a factor of 105. This presentation will report progress on the SERAPH experiment, a family of superconducting haloscopes being developed by the Superconducting Quantum Materials and Systems (SQMS) Center. In this presentation, I will first discuss the principles behind operating a haloscope whose bandwidth is much narrower than the dark matter halo energy distribution. I will then describe the first SERAPH experiments implementing a 1.3 GHz Niobium cavity with an ultra-high quality factor (Q~1010) that has achieved the best sensitivity and deepest exclusion to wavelike dark photon dark matter by almost an order of magnitude. Next, I will discuss progress on the next phase of SERAPH, which will search dark photon dark matter using a widely-tunable SRF cavity (4-7 GHz). I will finally describe plans for subsequent SERAPH experiments to search for dark photons and axions with tunable SRF cavities tolerant to multi-Tesla magnetic fields and quantum sensors that subvert the Standard Quantum Limit.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

SERAPH: Wavelike Dark Matter Searches with SRF Cavities

Haloscopes consisting of a microwave cavity with a high quality factor (Q) connected to low-noise electronics have been deployed to detect wavelike axions and dark photons. But the dark matter mass is unknown, so haloscopes must be tunable to search through the photon coupling vs. mass parameter space. Therefore, the scan rate for haloscope experiments is a crucial figure of merit and is proportional to the cavity’s quality factor. State-of-the-art experiments like ADMX currently use copper cavities with 𝑄∼80000. However, implementing superconducting cavities with 𝑄∼1010 can increase the instantaneous scan rate by possibly a factor of 105.This presentation will report progress on the SERAPH experiment, a family of superconducting haloscopes being developed by the Superconducting Quantum Materials and Systems (SQMS) Center. In this presentation, I will first discuss the principles behind operating a haloscope whose bandwidth is much narrower than the dark matter halo energy distribution. I will then describe the first SERAPH experiments implementing a 1.3 GHz Niobium cavity with an ultra-high quality factor (Q~1010) that has achieved the best sensitivity and deepest exclusion to wavelike dark photon dark matter by almost an order of magnitude. Next, I will discuss progress on the next phase of SERAPH, which will search dark photon dark matter using a widely-tunable SRF cavity (4-7 GHz). I will finally describe plans for subsequent SERAPH experiments to search for dark photons and axions with tunable SRF cavities tolerant to multi-Tesla magnetic fields and quantum sensors that subvert the Standard Quantum Limit.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

How Can Probabilistic Solar Power Forecasts Be Used to Lower Costs and Improve Reliability in Power Spot Markets? A Review and Application to Flexiramp Requirements

Net load uncertainty in electricity spot markets is rapidly growing. There are five general approaches by which system operators and market participants can use probabilistic forecasts of wind, solar, and load to help manage this uncertainty. These include operator situation awareness, resource risk hedging, reserves procurement, definition of contingencies, and explicit stochastic optimization. We review these approaches, and then provide a case study in which a method for using probabilistic solar forecasts to define needs for reserves is developed and evaluated. The case study has three parts. First, we describe building blocks for enhancing the Watt-Sun solar forecasting system to produce probabilistic irradiance and power forecasts. Second, relationships between Watt-Sun forecasts for multiple sites in California and the system's need for flexible ramp capability (flexiramp) are defined by machine learning and statistical methods. Third, the performance of present methods to defining flexiramp requirements, which are not conditioned on weather and renewables forecasts, is compared with that of probabilistic solar forecast-based requirements, using a multi-timescale production costing model with an 1820-bus representation of the WECC power system. Significant potential savings in fuel and flexiramp procurement costs from using solar-informed reserve requirements are found.

14 SOLAR ENERGY↗

North Carolina Water Utility Builds Resilience with Distributed Energy Resources

As the frequency and duration of grid outages increase, backup power systems are becoming more important for ensuring that critical infrastructure continues to provide essential services. Most facilities rely on diesel generators, which may be ineffective during long outages owing to limited fuel supplies and high generator failure rates. Distributed energy resources such as solar, storage, and combined-heat-and-power systems, coupled with on-site biofuel production, offer an alternative source of on-site generation that can provide both cost savings and resilience (i.e., the ability to respond to catastrophic events with longer-term consequences). A mixed-integer linear program minimizes costs and maximizes resilience at a wastewater treatment plant in Wilmington, North Carolina. We find that the plant can reduce life-cycle energy costs by 3.1% through the installation of a hybrid combined-heat-and-power, photovoltaic, and storage system. When paired with existing diesel generators, this system can sustain full load for seven days while saving $664,000 over 25 years and reducing diesel fuel use by 48% compared with the diesel-only solution. This analysis informed a decision by the Cape Fear Public Utility Authority to allocate funds for the implementation of a combined-heat-and-power system at the wastewater treatment plant in fiscal year 2023. Finally, the benefits of deploying hybrid combined-heat-and-power technologies and the utilization of on-site biofuel production extend, on a national scale, to thousands of wastewater treatment facilities and other types of critical infrastructure.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Power-Hardware-in-the-Loop Experiments of a Microgrid With a Grid-Forming Battery Inverter: Preprint

Microgrids continue to proliferate, and they are transitioning away from using conventional generating resources to increasingly relying on inverter-based resources (IBRs) as the voltage and frequency leaders. It is crucial to evaluate the capability of IBRs to provide microgrid stability and resilience. Hardware-in-the-loop (HIL) experiments were conducted to de-risk the field deployment of the San Diego Gas & Electric Company Borrego Springs Microgrid, where a battery inverter was upgraded with grid-forming (GFM) capability to serve as the island leader. This paper presents the HIL experimental results from an HIL test bed that uses a power-hardware-in-the-loop (PHIL) interface with a power inductor that was previously developed for PHIL simulations of microgrids where the inverters need to switch modes, i.e., between grid-following and GFM as the microgrid transitions between grid-connected and islanded operation. This paper presents more details on the interface and HIL simulation results of the planned islanding and load steps in islanded operation to show the effectiveness of the inverters in managing the voltage and frequency.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Momentary Cessation: Improving Dynamic Performance and Modeling of Utility-Scale Inverter Based Resources During Grid Disturbances

Sandia National Laboratories worked with NERC staff to provide stakeholder guidance in responding to a May 2018 NERC alert regarding dynamic performance and modeling issues for utility-scale inverter-based resources. The NERC alert resulted from event analyses for grid disturbances that occurred in southern California in August 2016 and October 2017. Those disturbances revealed the use of momentary cessation of transmission connected inverter-based generation- a short time period when they ceased to inject current into the grid, counter to desired transmission operation. The event analyses concluded that, in many cases, the Western Interconnection system models used to determine planning and operating criteria do not reflect the actual behavior of solar plants, resulting in overly optimistic planning assessments and substandard operational responses. This technical report summarizes the gaps between the models and actual performance that were observed at those times, and the guidance that Sandia and NERC provided to owners of solar PV power plants, transmission planners, transmission operators and planning/reliability coordinators to modify existing models to reflect that actual performance

24 POWER TRANSMISSION AND DISTRIBUTION↗

Securing Distributed Energy Resource Integration

The penetration of distributed energy resources (DER) is growing at much higher rates than predicted 20 years ago. Far from being used only in residential settings, DER are now installed on distribution and transmission circuits. In this position, they do not have the same properties as traditional generators and are more flexible in many cases. The growing penetration and range of uses for DER motivate the need to reliably and safely integrate them into the grid. Operators must be able to rely on them not only for normal operation, but also during abnormal conditions like black starts or adverse cyber scenarios. To that end, we study the communications, device interfaces, and potential consequences of DER operation under abnormal and adversarial conditions. The weaknesses of communications networks are studied based on the industrial protocols used, and the benefits of security features are examined. The device interfaces are found to be vulnerable to attack based on the requirements in the IEEE-1547 standard for DER interconnection and interoperability, which is expected to be adopted in the next ten years. In addition to exploring the requirements of the standard, we show that these vulnerabilities and others do exist and can be used maliciously in a modern storage system DER. Consequences of these vulnerabilities range from exacerbated grid instability, to simultaneous loss of large portions of DER penetration, to physical damage to inverters or DER themselves and other sensitive equipment. We tie these outcomes to specific attacker actions in an effort to give operators a better threat intelligence view that allows them to prioritize mitigations. Finally, we discuss mitigations that could prevent many of the adversarial scenarios described. Some solutions can be added to existing infrastructure, while others may require longer term planning for grid modernization with consideration for security.

25 ENERGY STORAGE↗