Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “distribution power grids”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 865 records · Page 48

Phasor-Based Control for Scalable Solar PV Integration

This project demonstrated that solar PV can be recruited to stabilize the grid, smooth out disturbances, manage power flows, and assist circuit switching operations. It developed a radically new, layered control framework for Distributed Energy Resources (DER) to act in response to real-time, measured conditions on their local distribution circuit, rather than waiting for a price signal to indicate preferred behavior. By enabling resources to act as good citizens on the electric grid, Phasor-Based Control (PBC) facilitates arbitrarily high solar penetration levels.

14 SOLAR ENERGY↗

Probability Density Function Control of Frequency Fluctuations in Renewable-Rich Power Systems

The stochastic nature of renewable energy sources (RESs) necessitates treating power system frequency response as a random process with a nonstationary probability density function (PDF). Here, based upon the stochastic distribution control theory originated by the second author, this paper proposes a novel stochastic controller to improve the frequency PDF in power grids when integrating a large amount of RESs, thereby minimizing the effects of uncertainties and enhancing overall system stability. The key idea is to manipulate the controllable power generation resources so that the frequency PDF is make to follow a target PDF by using the stochastic distribution control theory originated by the second author. The proposed method can easily be plugged into existing automatic generation controls for multi-area transmission grids. The proposed method is validated via a modified Kundar's two area system and 240-bus Western Electricity Coordinating Council systems. The simulation results show that the proposed control shapes the frequency PDF narrower and sharper, leading to a notable improvement toward minimizing the effects of randomness and uncertainty during grid operation.

frequency↗

What Role Do Aggregators Play in Power System Security and Resilience?

Barriers to the participation of distributed energy resources (DERs) in wholesale electricity markets have limited the use of DERs for power system security and resilience. In September 2020, the Federal Energy Regulatory Commission (FERC) approved an order to reduce these barriers. FERC Order No. 2222 enables the participation of DER aggregators in wholesale electricity markets. DERs include renewable generation and technologies that support the integration of renewable generation by increasing grid flexibility and resilience. Requiring wholesale energy markets to allow DER aggregator participation provides a path for DERs to become competitive in these markets. As the contribution from aggregated DERs continues to increase, the aggregator's role in supporting grid security and resilience will become more critical. This paper reviews work that demonstrates how DER aggregators can provide resilience support through technical capabilities, operational strategies, and secure communication architectures. Socioeconomic influences and impacts of aggregators, including implications for social resilience, are presented. In surveying the current state-of-the-art across different but interconnected topics, we illustrate how aggregators can be power system participants that enhance grid security. There is no one-size-fits-all approach to enhancing resilience in a power grid that includes a growing cohort of DER aggregators, but there are many options for aggregators to contribute to a more resilient and secure power grid.

aggregator↗

Advancing Grid Resilience through Smart Charge Management: Findings from Maryland’s Pilot

This report presents research findings from a four-year Smart Charge Management (SCM) pilot program conducted by Maryland’s largest electric utilities—Baltimore Gas and Electric (BGE), Potomac Electric Power Company (Pepco), and Delmarva Power & Light (DPL)—to evaluate strategies for optimizing electric vehicle (EV) charging loads and enhancing grid stability. Supported by the U.S. Department of Energy (DOE), Argonne National Laboratory collaborated with all project partners and examined the effectiveness of Time-of-Use (TOU) and Load Balancing (LB) strategies in managing peak demand, deferring costly infrastructure upgrades, and reducing grid constraints at the feeder level. Using charging data from over 4,600 EV drivers, the study analyzed SCM’s impact on the distribution systems of BGE and Pepco, which consists of over 2000 feeders. Unlike prior research that focused on system-wide trends or synthetic feeders, this analysis offers granular, feeder-level insights based on real-world operational data. It highlights how transformer density, load profiles, and infrastructure constraints influence smart charging performance. Results show feeder-level conditions play a crucial role in SCM effectiveness, with most feeders benefiting more from LB, while TOU-based SCM may be sufficient for others. By 2035, LB reduced peak charging loads by 27% on average, compared to 23% under TOU-based SCM, though some feeders saw reductions exceeding 35%, while others experienced minimal impact. Feeders with higher transformer utilization and limited capacity benefited more from LB, which more effectively distributed charging demand during off-peak hours. Beyond reducing grid constraints, SCM offers long-term operational and financial benefits. By shifting EV charging demand strategically, utilities can optimize asset utilization, delay infrastructure investments, and enhance grid performance. In terms of infrastructure upgrade deferrals, at the feeder level, LB consistently reduced peak charging loads and resulting infrastructure upgrade costs, particularly in high EV enrollment areas, decreasing the number of overloaded transformers by up to 35%, while TOU-based SCM achieved 20-30% reductions depending on feeder characteristics. At the system level, LB has the potential to defer total upgrade costs by $\$$186 million for BGE, compared to $\$$159 million under TOU-based SCM. For Pepco, TOU-based SCM performed slightly better, deferring upgrade costs by $\$$30 million, compared to $\$$29 million under LB. Section 4.5 reviews some of the system differences between BGE and Pepco. However, as EV adoption scales, TOU-based SCM will introduce secondary peak charging loads, reinforcing the need for more advanced, adaptive SCM approaches to prevent new grid challenges. As EV adoption continues to grow, feeder-level managed charging strategies will be essential for mitigating grid stress, improving infrastructure efficiency, and maintaining energy affordability for consumers. This report provides critical insights for utilities, Public Utility Commissions (PUCs), and state agencies on the role of feeder-specific smart charging in infrastructure planning, policy development, and grid modernization. The findings underscore the importance of tailored, data-driven SCM solutions that align with local grid conditions, ensuring a resilient, cost-effective transition to increasing EV adoption while safeguarding distribution system performance.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Natural Hazard Forecast Alert Grid Risk System

Weather events cause most power outages. Often, we even get notifications on our phones to take cover or be prepared for an imminent event. If electric grid utilities had a similar warning that also included probable scenarios and the equipment involved, they could prepare and minimize the effects. Idaho National Laboratory had a project with the U.S. Department of Energy’s Cybersecurity, Energy Security, and Emergency Response program to develop a grid alert application that receives messages from the existing emergency alert system, filters and determines components possibly affected by the emergency event, calculates probable scenarios using MASTERRI (Modeling And Simulation for Targeted Reliability and Resilience Improvement). For high-risk events, the application can then send alert links to subscribed electric distribution utility operations staff to allow them to see and evaluate the scenarios and the impact in a web based interactive map tool. This proof of concept application used data from utilities and organizations, such as the international regulatory body North American Electric Reliability Corporation, which have complied historical failure data of elements that comprise the U.S. electric grid. Nominal failure rates are obtained from this data. To make this tool possible, estimated failure rates were calculated for different component types given the alert type, severity, and location. Historic weather-related grid element failures were correlated with historic weather events from the Integrated Public Alert & Warning System. These correlated events and failures are used along with Bayesian updates from the historical norms to provide a modified failure rate for grid elements in the alert areas and calculate probable scenarios. Working with an industry collaborator, actual grid models and data were used for demonstration cases. This report outlines the work performed for this project.

24 - POWER TRANSMISSION AND DISTRIBUTION↗

Advanced Sensor Deployment for Distribution System State Estimation and Fault Identification

Distribution systems are currently facing steep operational challenges as a result of the rapidly increasing integration of renewables and other distributed energy resources (DERs) at both the primary and secondary circuit levels. Distribution utilities and system operators have traditionally had some visibility of their primary circuits using low-frequency supervisory control and data acquisition systems, and they have had very poor if not zero visibility of the secondary circuits where the presence of DERs is constantly increasing. Therefore, this paper presents simulation studies to demonstrate the benefits of an advanced, high-fidelity sensor technology, called as the Meta-Alert System (MAS), developed by Electrical Grid Monitoring, Ltd. (EGM), on the distribution grid. First, a reliable model of the EGM sensors is developed, and then two use cases, distribution system state estimation (DSSE) and fault identification are simulated to evaluate the performance of the MAS technology. Simulation results on the Electric Power Research Institute J1 feeder demonstrate that the MAS can effectively participate in system-level DSSE programs and can detect and locate faults faster than traditional distribution protection schemes.

distribution system↗

Power Grid Reliability Estimation via Adaptive Importance Sampling

Electricity production currently generates approximately 25% of greenhouse gas emissions in the USA. Thus, increasing the amount of renewable energy is a key step to carbon neutrality. However, integrating a large amount of fluctuating renewable generation is a significant challenge for power grid operating and planning. Grid reliability, i.e., an ability to meet operational constraints under power fluctuations, is probably the most important of them. In this letter, we propose computationally efficient and accurate methods to estimate the probability of line overflow, i.e., reliability constraints violation, under a known distribution of renewable energy generation. To this end, we investigate an importance sampling approach, a flexible extension of Monte-Carlo methods, which adaptively changes the sampling distribution to generate more samples near the reliability boundary. The approach allows to estimate overload probability in real-time based only on a few dozens of random samples, compared to thousands required by the plain Monte-Carlo. Our study focuses on high voltage direct current power transmission grids with linear reliability constraints on power injections and line currents. Herein, we propose a novel theoretically justified physics-informed adaptive importance sampling algorithm and compare its performance to state-of-the-art methods on multiple IEEE power grid test cases.

power system faults↗

COHORT: Coordination of Heterogeneous Thermostatically Controlled Loads for Demand Flexibility

Demand flexibility is increasingly important for power grids. Careful coordination of thermostatically controlled loads (TCLs) can modulate energy demand, decrease operating costs, and increase grid resiliency. We propose a novel distributed control framework for the Coordination Of HeterOgeneous Residential Thermostatically controlled loads (COHORT). COHORT is a practical, scalable, and versatile solution that coordinates a population of TCLs to jointly optimize a grid-level objective, while satisfying each TCL’s end-use requirements and operational constraints. To achieve that, we decompose the grid-scale problem into subproblems and coordi- nate their solutions to find the global optimum using the alternating direction method of multipliers (ADMM). The TCLs’ local problems are distributed to and computed in parallel at each TCL, making COHORT highly scalable and privacy-preserving. While each TCL poses combinatorial and non-convex constraints, we characterize these constraints as a convex set through relaxation, thereby making COHORT computationally viable over long planning horizons. After coordination, each TCL is responsible for its own control and tracks the agreed-upon power trajectory with its preferred strategy. In this work, we translate continuous power back to discrete on/off actuation, using pulse width modulation. COHORT is generalizable to a wide range of grid objectives, which we demonstrate through three distinct use cases: generation following, minimizing ramping, and peak load curtailment. In a notable experiment, we validated our approach through a hardware-in-the-loop simulation, including a real-world air conditioner (AC) controlled via a smart thermostat, and simulated instances of ACs modeled after real-world data traces. During the 15-day experimental period, COHORT reduced daily peak loads by an average of 12.5% and maintained comfortable temperatures.

demand response↗

Distribution System Blackstart and Restoration Using DERs and Dynamically Formed Microgrids

Extreme weather events have led to long-duration outages in the distribution system (DS), necessitating novel approaches to blackstart and restore the system. Existing blackstart solutions utilize blackstart units to establish multiple microgrids (MGs), sequentially energize non-blackstart units, and restore loads. However, these approaches often result in isolated MGs. In DERs-aided blackstart, the continuous operation of these MGs is limited by the finite energy capacity of commonly used blackstart units like battery energy storage (BES)-based gridforming inverters (GFMIs). To address this issue, this article proposes a holistic blackstart and restoration framework that incorporates synchronization between dynamic MGs and the entire DS with the transmission grid (TG). To support synchronization, we leveraged virtual synchronous generator-based control for GFMIs to estimate their frequency response to load pick-up events using only initial/final quasi-steady-state points. Subsequently, a synchronization switching condition is developed to model synchronizing switches, aligning them seamlessly with a linearized branch flow problem. Finally, we designed a bottomup blackstart and restoration framework that considers the switching structure of the DS, energizing/synchronizing switches, DERs with grid-following inverters, and BES-based GFMIs with frequency security constraints. In conclusion, the proposed framework is validated in IEEE-123-bus system, considering cases with two and four GFMIs under various TG recovery instants.

24 POWER TRANSMISSION AND DISTRIBUTION↗

UNIFI 1-MW Multi-Vendor Grid-Forming Inverter Test Updates

This presentation gives an update on UNIFI 1MW multi-vendor GFM inverter testing. The 1MW demo enters the last stage of the test, which is the integration test. And the main objectives of the integration tests include: 1) explore the interoperability of dispatching a future grid with energy mix (GFM inverters, GFL inverters and synchronous machine). The presentation highlights one example test, ROCOF, and summarizes all the key learning.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Short-Term Solar Forecasting Platform Using a Physics-Based Smart Persistence Model and Data Imputation Method

Electrical energy plays vital role in our socio-economic activity and therefore ensuring the reliability of the electric grid, from the generation, transmission and distribution level is critical. In order to maintain the power system parameter viz., frequency, voltage, etc., optimally, balancing of generation and consumption is very much essential. However, solar energy is infirm power by nature this is due to cloud cover / other local phenomena. Hence, Photovoltaic (PV) power generation brings a significant challenge to the grid operator due to the variability of the solar energy. The complexity of this challenge in terms of planning and dispatch ability of PV resources, aggravates with the high penetration of solar energy into the electric grid. In this setting, reliable solar radiation forecasting models based on accurate and quality input data become essential. In order to develop a suitable model for predicting solar radiation, quality historical / real time measurement is also needed. Under this study NIWE and NREL jointly developed / tested short-term solar forecasting frameworks using a smart persistence and physics-based smart persistence models for intra-hour forecasting of solar radiation (PSPI) and benchmarked 9 different data imputation techniques in 15 Solar Radiation Resource Assessment (SRRA) stations, located at different parts of India. During any measurement campaign, due to various technical reasons, we may miss few observations. However, the missing observation often reduce the performance of any forecasting model. Therefore, suitable data imputation method would assist us to obtain continuous observation of solar radiation. A station-by-station and method-by-method analysis was carried out to understand the performance of each model. Based on our analysis, among all the data imputation methods, the Kalman data imputation method is better for Indian Weather condition. In addition, Kalman StructTS, Linear, Stine and Arima methods yield slightly inferior accuracy compared to Kalman, but outperform the other methods. The extended solar radiation data are used by solar forecasting models to provide the prediction of solar radiation at 15 SRRA stations. As far as short term forecasting model is concerned, the PSPI model outperforms the Smart Persistence model. However, the forecast error is increases with the forecasting horizon.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

An XML-Based Protocol for Distributed Event Services

This viewgraph presentation provides information on the application of an XML (extensible mark-up language)-based protocol to the developing field of distributed processing by way of a computational grid which resembles an electric power grid. XML tags would be used to transmit events between the participants of a transaction, namely, the consumer and the producer of the grid scheme.

Smith, Warren↗

Unified Universal Control and Coordination of Inverter-Based Resources, and Validation for a PV + Battery Hybrid Plant

As renewable energy deployment grows, hybrid power plants (HPPs) combining photovoltaic (PV) and battery systems must evolve to offer both energy and grid stability services. These systems typically include a mix of grid-following (GFL) and grid-forming (GFM) inverters, presenting unique coordination and control challenges. This Department of Energy–funded project developed and validated a Unified Universal Control and Coordination (UUCC) framework for such PV + battery hybrid plants, enabling seamless and stable operation, including ultrafast black start, autonomous synchronization, and robust frequency and voltage regulation, under different grid conditions. The project significantly advanced the understanding of inverter-based resource (IBR) control by developing and validating three complementary system-level approaches for hybrid GFL/GFM operation: 1. A combined Virtual Resistance (VR)-based GFL and Virtual Oscillator Control (VOC)-based GFM method, where each inverter type is governed by a specialized control strategy. Together, these achieve stable, fast-response coordination, eliminating inrush current and enabling smooth black start and grid synchronization across a wide range of grid strengths. 2. A Deadbeat-based UUCC strategy, which uses discrete-time, switching-cycle-level control for both GFL and GFM inverters. This approach replaces traditional PI/PLL control with a control parameter-free, high-bandwidth framework that supports stable LVRT and instantaneous synchronization under all conditions. 3. A benchmark comparison with Siemens’ commercial GFM microgrid controller, which provided a fast baseline platform. The commercial approach decoupled v & f control was implemented on a commercial microgrid controller.The baseline commercial benchmark helped highlight superior transient response and black start performance offered by the deadbeat and VOC approaches. These technical contributions offer substantial improvements over conventional inverter control schemes, which often rely on slow phase-locked loop (PLL)-based synchronization, require careful control parameters tuning, and prone to unstable in weak grids with GFL inverters and in stiff grid with GFM inverters therefore challenging for hybrid GFL+GFM under all grid conditions. The deadbeat-based UUCC framework enables simpler, faster, and more robust operation of hybrid IBR systems using wide-bandgap (WBG) devices such as SiC power semiconductors. The rapid expansion of hybrid distributed energy resources (DERs), including residential and commercial PV-BESS installations such as Tesla Powerwall, PV with vehicle-to-grid (V2G) capability, and other integrated configurations, presents complex operational challenges for medium-voltage radial distribution feeders. These networks are subject to frequent disturbances such as faults, switching operations, rapid reclosing sequences, and feeder reconfigurations, all of which introduce dynamic stress on IBRs. In addition, planned feeder segmentation and deliberate islanding for resilience will require DERs that can autonomously perform blackstart, establish voltage and frequency references, and resynchronize with the main grid. The advanced deadbeat-based UUCC control and blackstart functionalities developed in this project directly address these requirements, enabling decentralized and autonomous operation of inverter-dominated DERs in distribution systems under a wide range of fault and reconfiguration scenarios. From a public benefit perspective, these innovations enable more reliable and cost-effective integration of renewable energy into distribution networks. The ability to autonomously black start and stabilize grids under varying grid conditions support accelerates recovery from outages and support decentralized resilient energy systems. By reducing system complexity and improving performance, this project lays critical groundwork for future inverter-dominated power grids that are clean, reliable, and accessible to all.

14 SOLAR ENERGY↗

VOLTTRON™ Agent Development for Enabling Reactive Power Support of Non-Utility DERs by Integrating Transactive Energy Approach

To enable better voltage regulation in power systems with high penetration of photovoltaics (PV) and other distributed energy resources (DERs), future inverters are required to provide reactive power support to the grid in addition to providing real power generated by PV panels. This paper develops a framework that coordinates the support from DER-based inverters, which are grid-connected non-utility assets, by using a transactive energy approach. Results of the implementation demonstrate participation of DER-based inverters can be achieved by using the coordination between distributed controllers and a centralized controller. With the transactive energy approach, both the customer and utility can achieve benefits that meet their individual needs.

Kritprajun, Paychuda↗

Supporting Cyber Security of Power Distribution Systems by Detecting Differences Between Real-time Micro-Synchrophasor Measurements and Cyber-Reported SCADA (Final Report)

As modern power grids tend towards greater levels of automation and communication, the challenges of identifying and mitigating vulnerabilities to cyber-attacks are ones that are increasingly demanding attention. Today’s power system has evolved to form the foundational bedrock of modern society, and an attack on this infrastructure could prove disastrous. In this project we were tasked to investigate the use of distribution synchrophasors as an independent isolated sensor network with which we can corroborate, or flag potentially spoofed,Supervisory Control And Data Acquisition (SCADA) data. We adapted an approach to marry the underlying physical properties of power systems with the network communications used by power systems in order to offer insights unattainable by either data stream isolation. While the concept of intrusion detection systems (IDS) is well understood for monitoring network traffic and traditional IT computing systems, the approach discussed in this report is motivated by several key notions: first, current SCADA communications alone presents an incomplete view of the grid. Second, the power grid, and the equipment controlling it, is grounded by laws of physics. Given this, we leverage high-frequency physical grid measurements to understand the physical condition of the grid, and combine this with SCADA. While high-frequency physical grid measurements and SCADA communication over Internet Protocol (IP) networks are fundamentally disparate information sources, when collectively examined through appropriate lenses, they offer a much more nuanced depiction of the grid.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Interoperability Maturity Roadmap Methodology, V1.3

The Interoperability Roadmap Methodology document supports the U.S. Department of Energy (DOE) Grid Modernization Laboratory Consortium (GMLC) Interoperability Project’s efforts to advance interoperability as an essential component for the successful and more seamless integration of intelligent, communicating technologies into the electric power system. This proposed methodology supports the strategic approach to advance interoperability described in the GMLC Interoperability Project’s Interoperability Strategic Vision: Enabling an Interactive Grid. That document proposes engaging an ecosystem of businesses interested in integrating smart technology with the electric power system to develop an interoperability roadmap using a methodical approach. This roadmap methodology is to be applied to technology integration ecosystems (e.g., electric vehicles, photovoltaic inverters, or automated buildings), using tools that measure the state of interoperability today, to identify the gaps and challenges that can be overcome to improve interoperability, and thereby, simplify the integration process.

24 POWER TRANSMISSION AND DISTRIBUTION↗