Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “diode effects”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 865 records · Page 48

Ultrawide bandgap vertical β-(Al x Ga1 −x )2O3 Schottky barrier diodes on free-standing β-Ga2O3 substrates

Ultrawide bandgap β-(AlxGa1−x)2O3 vertical Schottky barrier diodes on (010) β-Ga2O3 substrates are demonstrated. The β-(AlxGa1−x)2O3 epilayer has an Al composition of 21% and a nominal Si doping of 2 × 1017 cm−3 grown by molecular beam epitaxy. Pt/Ti/Au has been employed as the top Schottky contact, whereas Ti/Au has been utilized as the bottom Ohmic contact. The fabricated devices show excellent rectification with a high on/off ratio of ∼109, a turn-on voltage of 1.5 V, and an on-resistance of 3.4 mΩ cm2. Temperature-dependent forward current-voltage characteristics show effective Schottky barrier height varied from 0.91 to 1.18 eV while the ideality factor from 1.8 to 1.1 with increasing temperatures, which is ascribed to the inhomogeneity of the metal/semiconductor interface. The Schottky barrier height was considered a Gaussian distribution of potential, where the extracted mean barrier height and a standard deviation at zero bias were 1.81 and 0.18 eV, respectively. A comprehensive analysis of the device leakage was performed to identify possible leakage mechanisms by studying temperature-dependent reverse current-voltage characteristics. At reverse bias, due to the large Schottky barrier height, the contributions from thermionic emission and thermionic field emission are negligible. By fitting reverse leakage currents at different temperatures, it was identified that Poole–Frenkel emission and trap-assisted tunneling are the main leakage mechanisms at high- and low-temperature regimes, respectively. Electrons can tunnel through the Schottky barrier assisted by traps at low temperatures, while they can escape these traps at high temperatures and be transported under high electric fields. This work can serve as an important reference for the future development of ultrawide bandgap β-(AlxGa1−x)2O3 power electronics, RF electronics, and ultraviolet photonics.

Materials Science↗

Non-planar growth of high Al-mole-fraction AlGaN on patterned GaN platforms for mitigating strain-induced cracks beyond the critical layer thickness

Non-planar growth of Al x Ga 1-x N epitaxial layers with an average alloy composition up to Al-mole-fraction of x ~ 0.21 was performed on patterned c-plane GaN on (0001) sapphire substrates with stripe-shaped mesa structures. This approach successfully realized the growth of crack-free AlGaN layers on the top of mesas with layer thicknesses greater than the expected critical layer thickness by relaxing the in-plane stress on the top of the mesa. The effectiveness of the relaxation strongly depends on the width and depth of the stripe mesa. In conclusion, the relaxation of in-plane stress and resultant suppression of cracks in AlGaN layer are qualitatively discussed.

36 MATERIALS SCIENCE↗

H 2 O absorption spectroscopy via focused laser differential interferometry

A modification of focused laser differential interferometry (FLDI) is demonstrated with an infrared tunable diode laser (TDL) to achieve simultaneous absorption spectroscopy (AS) measurements. Measurements from this absorbing-FLDI (A-FLDI) are shown for a Hencken burner plume. Initial comparison measurements are recorded using TDLAS and an electrical hygrometer. Raw voltage and estimated absorbance measurements illustrate that the technique detects five distinct absorbance peaks of the methane–air flame while retaining the expected behavior of typical FLDI. This modification furthers efforts to enable FLDI to conduct analysis of the pressures, temperatures, and molecular densities of flows. It also explores the potential for reducing path-integration (PI) effects in absorption spectroscopy and potentially enabling spatially and temporally resolved local flow measurements. Reductions in PI length as high as 82%–84% are observed.

Holladay, Seth (ORCID:0009000650875421)↗

Precision Timing in CMS at the HL-LHC: Current Progress on Validation and Production

During the High Luminosity phase of LHC, up to 200 proton-proton collisions per bunch crossing will bring severe challenges for event reconstruction. To mitigate pileup effects, an extended upgrade program of the CMS experiment is expected. Among which, a new timing layer, the MIP Timing Detector (MTD), will be integrated between the tracker and the calorimeters. With a time resolution of 30-60 ps, the MTD will enable 4D vertexing, bringing significant improvements in track-to-vertex association and object identification. The MTD is composed of two subsystems based on different technologies: the Barrel Timing Layer (BTL) consists of LYSO:Ce scintillating crystals readout by SiPMs, and the Endcap Timing Layer (ETL) is made of Low-Gain Avalanche Diodes. The BTL is currently under production, while ETL sensor prototyping and validation are ongoing. Recent system tests have confirmed the performance of the full acquisition chain. This talk will provide an overview of the MTD design, along with the physics motivation, and the current status of BTL construction and ETL development.

Safdari, Murtaza [Fermilab] (ORCID:000000018323731↗

Cable Tester Box

Cables are very important electrical devices that carry power and signals across multiple instruments. Any fault in a cable can easily result in a catastrophic outcome. Therefore, verifying that all cables are built to spec is a very important part of Electrical Integration Procedures. Currently, there are two methods used in lab for verifying cable connectivity. (1) Using a Break-Out Box and an ohmmeter this method is time-consuming but effective for custom cables and (2) Commercial Automated Cable Tester Boxes this method is fast, but to test custom cables often requires pre-programmed configuration files, and cables used on spacecraft are often uniquely designed for specific purposes. The idea is to develop a semi-automatic continuity tester that reduces human effort in cable testing, speeds up the electrical integration process, and ensures system safety. The JPL-Cable Tester Box is developed to check every single possible electrical connection in a cable in parallel. This system indicates connectivity through LED (light emitting diode) circuits. Users can choose to test any pin/shell (test node) with a single push of a button, and any other nodes that are shorted to the test node, even if they are in the same connector, will light up with the test node. The JPL-Cable Tester Boxes offers the following advantages: 1. Easy to use: The architecture is simple enough that it only takes 5 minutes for anyone to learn how operate the Cable Tester Box. No pre-programming and calibration are required, since this box only checks continuity. 2. Fast: The cable tester box checks all the possible electrical connections in parallel at a push of a button. If a cable normally takes half an hour to test, using the Cable Tester Box will improve the speed to as little as 60 seconds to complete. 3. Versatile: Multiple cable tester boxes can be used together. As long as all the boxes share the same electrical potential, any number of connectors can be tested together.

Lee, Jason H.↗

NASA Tech Briefs, August 2012

Topics covered include: Mars Science Laboratory Drill; Ultra-Compact Motor Controller; A Reversible Thermally Driven Pump for Use in a Sub-Kelvin Magnetic Refrigerator; Shape Memory Composite Hybrid Hinge; Binding Causes of Printed Wiring Assemblies with Card-Loks; Coring Sample Acquisition Tool; Joining and Assembly of Bulk Metallic Glass Composites Through Capacitive Discharge; 670-GHz Schottky Diode-Based Subharmonic Mixer with CPW Circuits and 70-GHz IF; Self-Nulling Lock-in Detection Electronics for Capacitance Probe Electrometer; Discontinuous Mode Power Supply; Optimal Dynamic Sub-Threshold Technique for Extreme Low Power Consumption for VLSI; Hardware for Accelerating N-Modular Redundant Systems for High-Reliability Computing; Blocking Filters with Enhanced Throughput for X-Ray Microcalorimetry; High-Thermal-Conductivity Fabrics; Imidazolium-Based Polymeric Materials as Alkaline Anion-Exchange Fuel Cell Membranes; Electrospun Nanofiber Coating of Fiber Materials: A Composite Toughening Approach; Experimental Modeling of Sterilization Effects for Atmospheric Entry Heating on Microorganisms; Saliva Preservative for Diagnostic Purposes; Hands-Free Transcranial Color Doppler Probe; Aerosol and Surface Parameter Retrievals for a Multi-Angle, Multiband Spectrometer LogScope; TraceContract; AIRS Maps from Space Processing Software; POSTMAN: Point of Sail Tacking for Maritime Autonomous Navigation; Space Operations Learning Center; OVERSMART Reporting Tool for Flow Computations Over Large Grid Systems; Large Eddy Simulation (LES) of Particle-Laden Temporal Mixing Layers; Projection of Stabilized Aerial Imagery Onto Digital Elevation Maps for Geo-Rectified and Jitter-Free Viewing; Iterative Transform Phase Diversity: An Image-Based Object and Wavefront Recovery; 3D Drop Size Distribution Extrapolation Algorithm Using a Single Disdrometer; Social Networking Adapted for Distributed Scientific Collaboration; General Methodology for Designing Spacecraft Trajectories; Hemispherical Field-of-View Above-Water Surface Imager for Submarines; and Quantum-Well Infrared Photodetector (QWIP) Focal Plane Assembly.

Source record↗

Space Launch System Base Heating Test: Tunable Diode Laser Absorption Spectroscopy

This paper describes the Tunable Diode Laser Absorption Spectroscopy (TDLAS) measurement of several water transitions that were interrogated during a hot-fire testing of the Space Launch Systems (SLS) sub-scale vehicle installed in LENS II. The temperature of the recirculating gas flow over the base plate was found to increase with altitude and is consistent with CFD results. It was also observed that the gas above the base plate has significant velocity along the optical path of the sensor at the higher altitudes. The line-by-line analysis of the H2O absorption features must include the effects of the Doppler shift phenomena particularly at high altitude. The TDLAS experimental measurements and the analysis procedure which incorporates the velocity dependent flow will be described.

Parker, Ron↗

Space Launch System Base Heating Test: Tunable Diode Laser Absorption Spectroscopy

This paper describes the Tunable Diode Laser Absorption Spectroscopy (TDLAS) measurement of several water transitions that were interrogated during a hot-fire testing of the Space Launch Systems (SLS) sub-scale vehicle installed in LENS II. The temperature of the recirculating gas flow over the base plate was found to increase with altitude and is consistent with CFD results. It was also observed that the gas above the base plate has significant velocity along the optical path of the sensor at the higher altitudes. The line-by-line analysis of the H2O absorption features must include the effects of the Doppler shift phenomena particularly at high altitude. The TDLAS experimental measurements and the analysis procedure which incorporates the velocity dependent flow will be described.

Parker, Ron↗

Microgap breakdown with floating metal rod perturbations

Here, we report the characterization of microgap breakdown with perturbations from a metal rod floating between anode and cathode electrodes. The effects of the metal rod on the electric field distribution and the field enhancement factor are evaluated by numerical simulation and the conformal mapping method, and they indicate that the field emission regime is not reached. The breakdown voltages in the Townsend discharge regime are determined based on the voltage–current characteristics, which are obtained from two-dimensional fluid simulations. It is found that the breakdown characteristics can be significantly modulated by the floating metal rod, and the breakdown curve (breakdown voltage vs the net gap distance) is no longer U-shaped, which deviates from the conventional Paschen's law. The underlying physical mechanisms are related to the electric field enhancement, curved breakdown path, and nonuniform ion flux caused by the electric shielding effect. The results provide insights into breakdown characteristics in microscale discharges, which may promote conventional investigation of simplified clean gaps toward more complex conditions (e.g., with floating microparticles) in miniaturized plasma devices.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Multichannel Fiber-Optic Silicon Fabry–Pérot Interferometric Bolometer System for Plasma Radiation Measurements

A single-channel fiber-optic bolometer system based on a high-finesse silicon Fabry–Pérot interferometer (FPI) was previously reported, intended to measure plasma radiation from the magnetically confined fusion chamber. Recently, we developed a multichannel fiber-optic bolometer system with five bolometers multiplexed using a coarse wavelength division multiplexer (CWDM) and interrogated with a white-light system involving a superluminescent light-emission diode source and a high-speed spectrometer. One of the bolometers was used as the reference bolometer to compensate for the ambient temperature variations, and the other four bolometers were used for radiation measurement. The bolometers have a simple structure with a silicon pillar at the end of the single-mode fiber and a gold disk on the other side of the silicon pillar. They are also easy to fabricate without stringent requirements on the optical alignment. Analysis of the system optimization was performed to improve the noise performance and to mitigate the vibration effect that may present in the practical application. The system had a significantly enhanced measurement range compared to the previous high-finesse FPI bolometer system for measuring radiation. Test results performed in air using a 405 nm laser as the radiation source showed that the temperature resolution and the noise-equivalent power density of the sensing bolometers connected to each channel of the CWDM were, respectively, ~0.4 mK and ~0.1 W/m2, with a time constant of ~220 ms, which is comparable to the previous more complicated fiber-optic bolometer systems based on high-finesse FPIs that were interrogated using wavelength-scanning lasers.

Uddin, Nezam↗

Sunspot bright rings and the thermal diffusivity of solar convection

Raster-scan observations of 10 sunspots, made in 1980 and 1981 with the 512-channel diode array and vacuum telescope at the Kitt Peak National Observatory, are reported. Data from several 10-min scans of 0.25-A passbands of clean continuum were summed to give an rms noise level of 0.25 percent, corrected by applying a limb-darkening curve, and analyzed to determine the average intensity for each of eight segments of a series of concentric rings around each sunspot. Faculae and pores were identified and discarded in constructing radial intensity profiles. Marginally significant bright symmetric rings (peak amplitude 0.1-0.3 percent) not attributable to residual facular signal or instrumental effects were observed around 6 of 10 sunspots. No evidence of more intense bright rings was found. These findings are discussed in terms of thermal-diffusion models proposed to explain the fate of the radiative flux blocked by sunspots.

Duvall, T., Jr.↗

Flight Testing of a Cryogenic Capillary Pumped Loop

Future space-based cryogenic systems will require enhanced integration flexibility, lower weight reduced parasitic penalties, better vibration isolation, and a variety of other improvements to meet performance goals. Additionally, there is an increasing need to locate cooling sources remotely from cooled components. In the past flexible conductive links were used and worked well in most cases. However, as the transport lengths increase, conductive couplings become heavier and less effective, and must be replaced by higher performance systems. One available option, which can meet many of these future requirements, is the cryogenic capillary pumped loop (CCPL). The development of the CCPL technology started in 1992, following the success of the room temperature CPLS. The extrapolation of CCPL technology to cryogenic temperatures offers many performance benefits, which are not currently within the reach of traditional heat pipes or conductive links. Specific advantages of the CCPL technology pertaining to cryocooler integration include: (1) greater capillary pumping pressure for improved ground testability; (2) improved mechanical isolation; (3) faster diode shutdown and lower reverse heat leaks; (4) tighter control of detector temperature; (5) variable or fixed conductance operation; and (6) ease of integration due to their flexibility. The applications of CCPL technology are numerous. Military and commercial applications include surveillance satellites, earth observing satellites, deep space observation systems, medical devices, and many other cryogenic systems. Over the past few years, several breadboard and prototype CCPLs have been built and ground tested. A prototype CCPL has demonstrated successful operation between 80K and 110K with heat loads between O.5W and 12W using nitrogen as the working fluid, and 35K and 40K with head loads of 0.25W to 3.5W using neon. In order to verify CCPL performance in a microgravity environment, a flight unit, CCPL-5, was tested onboard the Space Shuttle STS-95 in October of 1998 as part of the CRYOTSU Flight Experiment. This flight was the first in-space demonstration of the CCPL. The CCPL-5 utilized nitrogen as the working fluid and operated between 75K and 110K. Flight results indicated excellent performance of the CCPL-5 under zero-G environment The CCPL could start from a supercritical condition in all tests, and the loop operating temperature could be tightly controlled regardless of changes in the heat load and/or the sink temperature. In addition, the loop demonstrated successful operation with a heat load of 0.5W as well as with parasitic heat loads alone. There were no noticeable differences between zero-G and one-G operation.

Ku, Jentung↗

Circuit and Method for Communication Over DC Power Line

A circuit and method for transmitting and receiving on-off-keyed (OOK) signals with fractional signal-to-noise ratios uses available high-temperature silicon- on-insulator (SOI) components to move computational, sensing, and actuation abilities closer to high-temperature or high-ionizing radiation environments such as vehicle engine compartments, deep-hole drilling environments, industrial control and monitoring of processes like smelting, and operations near nuclear reactors and in space. This device allows for the networking of multiple, like nodes to each other and to a central processor. It can do this with nothing more than the already in-situ power wiring of the system. The device s microprocessor allows it to make intelligent decisions within the vehicle operational loop and to effect control outputs to its associated actuators. The figure illustrates how each node converts digital serial data to OOK 18-kHz in transmit mode and vice-versa in receive mode; though operations at lower frequencies or up to a megahertz are within reason using this method and these parts. This innovation s technique modulates a DC power bus with millivolt-level signals through a MOSFET (metal oxide semiconductor field effect transistor) and resistor by OOK. It receives and demodulates this signal from the DC power bus through capacitive coupling at high temperature and in high ionizing radiation environments. The demodulation of the OOK signal is accomplished by using an asynchronous quadrature detection technique realized by a quasi-discrete Fourier transform through use of the quadrature components (0 and 90 phases) of the carrier frequency as generated by the microcontroller and as a function of the selected crystal frequency driving its oscillator. The detected signal is rectified using an absolute-value circuit containing no diodes (diodes being non-operational at high temperatures), and only operational amplifiers. The absolute values of the two phases of the received signal are then summed and hard limited (digitized) by comparing them to a reference level and are then input into a microprocessor as a serial bit stream. The quasi-discrete Fourier transform is performed in high-temperature components (operational amplifiers, analog switches, resistors, and capacitors). The demodulated signal is a serial data stream that is input to the UART (universal asynchronous receiver transmitter) receiver pin of the microprocessor. The OOK of the carrier frequency uses the output of the UART pin as an enabling signal that drives the gate of the MOSFET. Logic low bits enable the carrier frequency (realized by using the 0 phase signal from the microcontroller, though either phase may be used) to be DC-coupled to the power supply bus through a current-limiting resistor mounted between the MOSFET drain and the supply rail. The presence of logic lows on the power supply rail is realized by carrier bursts while logic highs are realized by the absence of bursts.

Krasowski, Michael J.↗

Switched-beam radiometer front-end network analysis

The noise figure performance of various delay-line networks fabricated from microstrip lines with varying number of elements was investigated using a computer simulation. The effects of resistive losses in both the transmission lines and power combiners were considered. In general, it is found that an optimum number of elements exists, depending upon the resistive losses present in the network. Small resistive losses are found to have a significant degrading effect upon the noise figure performance of the array. Extreme stability in switching characteristics is necessary to minimize the nondeterministic noise of the array. For example, it is found that a 6 percent tolerance on the delay-line lengths will produce a 0.2 db uncertainty in the noise figure which translates into a 13.67 K temperature uncertainty generated by the network. If the tolerance can be held to 2 percent, the uncertainty in noise figure and noise temperature will be 0.025 db and 1.67 K, respectively. Three phase shift networks fabricated using a commercially available PIN diode switch were investigated. Loaded-line phase shifters are found to have desirable RF and noise characteristics and are attractive components for use in phased-array networks.

Trew, R. J.↗

Comparative Soot Diagnostics: Preliminary Results

The motivation for the Comparative Soot Diagnostics (CSD) experiment lies in the broad practical importance of understanding combustion generated particulate. Depending upon the circumstances, particulate matter can affect the durability and performance of combustion equipment, can be a pollutant, can be used to detect fires and, in the form of soot, can be the dominant source of radiant energy from flames. The nonbuoyant structure of most flames of practical interest makes understanding of soot processes in low gravity flames important to our ability to predict fire behavior on earth. These studies also have direct applications to fire safety in human-crew spacecraft, since smoke is the indicator used for automated detection in current spacecraft. In the earliest missions (Mercury, Gemini and Apollo), the crew quarters were so cramped that it was considered reasonable that the astronauts would rapidly detect any fire. The Skylab module, however, included approximately 20 UV-sensing fire detectors. The Space Shuttle has 9 particle-ionization smoke detectors in the mid-deck and flight deck and Spacelab has six additional particle-ionization smoke detectors. The designated detectors for the ISS are laser-diode, forward-scattering, smoke or particulate detectors. Current plans for the ISS call for two detectors in the open area of the module, and detectors in racks that have both cooling air flow and electrical power. Due to the complete absence of data concerning the nature of particulate and radiant emission from incipient and fully developed low-g fires, all three of these detector systems were designed based upon l-g test data and experience. As planned mission durations and complexity increase and the volume of spacecraft increases, the need for and importance of effective, crew-independent, fire detection grows significantly. To provide this level of protection, more knowledge is needed concerning low-gravity fire phenomena and, in particular, how they might be detected and suppressed. Prior to CSD, no combustion-generated particulate samples had been collected near the flame zone for well-developed microgravity flames. All of the extant data either came from drop tower tests and therefore only corresponded to the early stages of a fire or were collected far from the flame zone. The fuel sources in the drop tower tests were restricted to laminar gas-jet diffusion flames and very rapidly overheated wire insulation. The gas-jet tests indicated, through thermophoretic sampling, (2) that soot primaries and aggregates (groups of primary particles) in low-gravity may be significantly larger than those in normal gravity (1-g). This raises new scientific questions about soot processes as well as practical issues for particulate size sensitivity and detection alarm threshold levels used in on-orbit smoke detectors. Preliminary tests in the 2.2 second drop tower suggest that particulate generated by overheated wire insulation may be larger in low-g than in 1-g. Transmission Electron Microscope (TEM) grids downstream of the fire region in the Wire Insulation Flammability experiment as well as visual observation of long string-like aggregates, further confirm this suggestion. The combined impact of these limited results and theoretical predictions is that, as opposed to extrapolation from l-g data, direct knowledge of low-g combustion particulate is needed for more confident design of smoke detectors for spacecraft. This paper describes the operation and preliminary results of the CSD, a project conceived and developed at NASA Lewis Research Center. The CSD flight experiment was conducted in the Middeck Glovebox Facility (MGBX) on USMP-3. The project is support by NASA Headquarters Microgravity Science and Applications Division and Code Q. The results presented here are from the microgravity portion of the experiment, including the temporal response of the detectors and average sizes of the primary and aggregate particles captured on the thermophoretic probes.

Urban, David L.↗

Injection mechanisms in a III -nitride light-emitting diode as seen by self-emissive electron microscopy

Here, we report on the investigation of an electrically biased high efficiency green III-nitride light-emitting diode (LED) by electron emission microscopy (EEM) using a low-energy electron microscope (LEEM). The surface of the LED was activated to negative electron affinity via deposition of a submonolayer of Cs. With the illumination column of the LEEM turned off, upon electrical injection of the LED, we directly image the hot electrons generated by eeh Auger-Meitner nonradiative processes that diffuse through the top p-Ga N layer and emit out the surface of the biased LED. By determining the source of emitted electrons using complementary electron emission spectroscopy measurements, EEM allows us to effectively map the carrier density within the LED. Using EEM, we observed nonelectron emitting regions with a density of approximately 3 × 10 8 cm -2 , identified as V-shaped defects (V-defects). This is confirmed through the corresponding dark spots of panchromatic cathodoluminescence measurements of the same sample and by plan-view transmission electron microscopy. The absence of electron emission at the sidewall of the V-defects can be attributed to several factors, including reduced carrier density in the sidewall quantum wells due to carriers traveling fast through the semipolar sidewalls before being injected into the planar quantum wells, the reduced population of hot electrons surviving diffusion through the thicker p-GaN filling in the V-defect before emission onto vacuum, and a smaller Auger-Meitner coefficient for the low In content semipolar sidewall quantum wells. The stronger electron emission observed at the ridges of most V-defects compared to the planar quantum well regions indicates larger local injected carrier densities, confirming that V-defect sidewalls allow for strong lateral carrier injection when compared to the weaker vertical injection away from the V-defect as evidenced by the weaker electron emission intensity away from the V-defects.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Manufacturable Corrugated Substrates for High Efficiency Organic Light-Emitting Diodes (OLEDs)

In this project, we start with optical simulation of an OLED to have a basic understanding of the mode dispersion inside the device. We first fabricated 1-D photonic crystals’ (PhCs) for corrugated green OLED devices observed enhanced EQE from 20% to 27%, which has the drawbacks of angular color shift. To resolve this issue, we fabricated poly crystalline PhCs (poly PhC) devices and observed alleviated angular color shift. The outcoupling efficiency is enhanced from 30% to 35%, which can be further enhanced to 60% by extracting the substrate mode. To further enhance the efficiency, we used RCWA (rigorous coupled-wave analysis) simulation to study the optical property in the corrugated device. We found out the corrugation reduces the reflectance of the Al cathode, lowers the cavity resonance and weakens the cavity emission. To preserve the cavity effect, we insert a low index Teflon layer (n = 1.3) between the ITO anode and the corrugated substrate, which increased the index contrast and hence the reflectance of the bottom electrode. As a result, the corrugated OLED with a Teflon layer shows a maximum outcoupling efficiency of 75%.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Determination of electrical parameters of ITO/CZTS/CdS/Ag and ITO/CdS/CZTS/Ag heterojunction diodes in dark and illumination conditions

In this work, ITO/CZTS/CdS/Ag and ITO/CdS/CZTS/Ag heterojunction diodes has been produced, CdS and CZTS thin film layers of the diode have been produced on ITO glass at room temperature using PLD technique. It has been produced CZTS thin films that have a polycrystalline structure that were annealed at the sulfurization temperatures of 325 °C, 350 °C and 375 °C when as-grown CZTS thin film has the amorphous structure. CdS thin films have been grown on substrate at room temperature in 15, 20 and 25 min that have polycrystalline structures. Then, CdS thin film deposited for 20 min was annealed at 200 °C temperature and, has better crystal structure compared to other thin films. Diodes have been composed of CZTS thin film annealed in 375 °C, CdS thin film was grown during 20 min and, then annealed at 200 °C temperature. According to J–V characteristics of diode, diodes exhibit some rectification behaviour in dark and show a photo-electric property under illumination conditions. In this article, the ideality factors of diodes in dark condition have been calculated, their electrical parameters of J{sub sc}, V{sub oc}, FF and η under the illumination condition have been determined and these electrical properties have been discussed in details.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗