Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “devices”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 865 records · Page 48

Compact, Controlled Resistance Exercise Device

Spaceflight leads to muscle and bone atrophy. Isoinertial (free-weight) exercises provide a sufficient stimulus to elicit increases in both muscle strength and bone mineral density in Earth-based studies. While exercise equipment is in use on the International Space Station for crewmember health maintenance, current devices are too large to place in a transport vehicle or small spacecraft. Therefore, a portable computer controlled resistance exercise device is being developed that is able to simulate the inertial loading experienced when lifting a mass on Earth. This portable device weighs less than 50 lb and can simulate the resistance of lifting and lowering up to 600 lb of free-weights. The objective is to allow crewmembers to perform resistance exercise with loads capable of maintaining muscle and bone health. The device is reconfigurable and allows for the performance of typical Earth-based free-weight exercises. Forces exerted, volume of work, range of motion, time-under-tension, and speed/ acceleration of movement are recorded and can be remotely monitored to track progress and modify individual protocols based on exercise session data. A performance evaluation will be completed and data will be presented that include ground-reaction force comparisons between the device and free-weight dead-lifts over a spectrum of resistance levels. Movement biomechanics will also be presented.

Paulus, David C.↗

Development of a Novel Self-Enclosed Sample Preparation Device for DNA/RNA Isolation in Space

Modern biology techniques present potentials for a wide range of molecular, cellular, and biochemistry applications in space, including detection of infectious pathogens and environmental contaminations, monitoring of drug-resistant microbial and dangerous mutations, identification of new phenotypes of microbial and new life species. However, one of the major technological blockades in enabling these technologies in space is a lack of devices for sample preparation in the space environment. To overcome such an obstacle, we constructed a prototype of a DNA/RNA isolation device based on our novel designs documented in the NASA New Technology Reporting System (MSC-24811-1/3-1). This device is self-enclosed and pipette free, purposely designed for use in the absence of gravity. Our design can also be modified easily for preparing samples in space for other applications, such as flowcytometry, immunostaining, cell separation, sample purification and separation according to its size and charges, sample chemical labeling, and sample purification. The prototype of our DNA/RNA isolation device was tested for efficiencies of DNA and RNA isolation from various cell types for PCR analysis. The purity and integrity of purified DNA and RNA were determined as well. Results showed that our developed DNA/RNA isolation device offers similar efficiency and quality in comparison to the samples prepared using the standard protocol in the laboratory.

Zhang, Ye↗

Device for Locking a Control Knob

A simple, effective, easy-to-use device locks a control knob in a set position. In the initial application for which this device was conceived, the control knob to be locked is that of a needle valve. Previously, in that application, it was necessary for one technician to hold the knob to keep the valve at the desired flow setting while another technician secured the valve with safety wire -- a time-consuming procedure. After attachment of the wire, it was still possible to turn the knob somewhat. In contrast, a single technician using the present device can secure the knob in the desired position. in about 30 seconds, and the knob cannot thereafter be turned, even in the presence of harsh vibrations, which occur during space shuttle launch. The device includes a special-purpose clamp that fits around the control knob and its shaft and that can be tightened onto the knob, without turning the knob, by means of two thumbscrews. The end of the device opposite the clamp is a tang that contains a slot that, in turn, engages a bolt that protrudes from the panel on which the control knob and its shaft are mounted.

Grom, Dave↗

Quality Control Method for a Micro-Nano-Channel Microfabricated Device

A variety of silicon-fabricated devices is used in medical applications such as drug and cell delivery, and DNA and protein separation and analysis. When a fluidic device inlet is connected to a compressed gas reservoir, and the outlet is at a lower pressure, a gas flow occurs through the membrane toward the outside. The method relies on the measurement of the gas pressure over the elapsed time inside the upstream and downstream environments. By knowing the volume of the upstream reservoir, the gas flow rate through the membrane over the pressure drop can be calculated. This quality control method consists of measuring the gas flow through a device and comparing the results with a standard curve, which can be obtained by testing standard devices. Standard devices can be selected through a variety of techniques, both destructive and nondestructive, such as SEM, AFM, and standard particle filtration.

Grattoni, Alessandro↗

Performance and Characterization of Magnetic Penetration Thermometer Devices for X-Ray Spectroscopy

We are developing magnetic penetration thermometers (MPTs) for applications in X-ray astronomy. These non-dissipative devices consist of an X-ray absorber in good thermal contact to a superconducting thin film with a transition temperature around T=100mK. A microfabricated superconducting planar inductor underneath is used to store a persistent current and couple the superconductor's diamagnetic response to a readout SQUID. The strong temperature dependence of the diamagnetic response make these devices suitable for highly sensitive macroscopic thermometers that are capable of achieving very high energy resolution. We present results achieved with MPTs consisting of MoAu bilayer sensors attached to overhanging square 250 micron by 250 micron gold absorbers that have demonstrated an energy resolution of delta E_FWHM=2.3eV at an X-ray energy of 5.9keV. A similar device has shown delta E_FWHM=2.0eV at 1.5 keV. Under certain conditions and for specific device geometries, the temperature responsivity of the MPTs can vary on long timescales degrading the spectral performance. We present the characterization of different inductor geometries to optimize the design for the highest possible temperature sensitivity and compare different device designs with respect to responsivity stability.

Porst, J. -P.↗

Use of a Frequency Divider to Evaluate an SOI NAND Gate Device, Type CHT-7400, for Wide Temperature Applications

Frequency dividers constitute essential elements in designing phase-locked loop circuits and microwave systems. In addition, they are used in providing required clocking signals to microprocessors and can be utilized as digital counters. In some applications, particularly space missions, electronics are often exposed to extreme temperature conditions. Therefore, it is required that circuits designed for such applications incorporate electronic parts and devices that can tolerate and operate efficiently in harsh temperature environments. While present electronic circuits employ COTS (commercial-off- the-shelf) parts that necessitate and are supported with some form of thermal control systems to maintain adequate temperature for proper operation, it is highly desirable and beneficial if the thermal conditioning elements are eliminated. Amongst these benefits are: simpler system design, reduced weight and size, improved reliability, simpler maintenance, and reduced cost. Devices based on silicon-on-insulator (SOI) technology, which utilizes the addition of an insulation layer in the device structure to reduce leakage currents and to minimize parasitic junctions, are well suited for high temperatures due to reduced internal heating as compared to the conventional silicon devices, and less power consumption. In addition, SOI electronic integrated circuits display good tolerance to radiation by virtue of introducing barriers or lengthening the path for penetrating particles and/or providing a region for trapping incident ionization. The benefits of these parts make them suitable for use in deep space and planetary exploration missions where extreme temperatures and radiation are encountered. Although designed for high temperatures, very little data exist on the operation of SOI devices and circuits at cryogenic temperatures. In this work, the performance of a divide-by-two frequency divider circuit built using COTS SOI logic gates was evaluated over a wide temperature range and thermal cycling to determine suitability for use in space exploration missions and terrestrial fields under extreme temperature conditions.

Patterson, Richard L.↗

Analytic Couple Modeling Introducing Device Design Factor, Fin Factor, Thermal Diffusivity Factor, and Inductance Factor

A set of convenient thermoelectric device solutions have been derived in order to capture a number of factors which are previously only resolved with numerical techniques. The concise conversion efficiency equations derived from governing equations provide intuitive and straight-forward design guidelines. These guidelines allow for better device design without requiring detailed numerical modeling. The analytical modeling accounts for factors such as i) variable temperature boundary conditions, ii) lateral heat transfer, iii) temperature variable material properties, and iv) transient operation. New dimensionless parameters, similar to the figure of merit, are introduced including the device design factor, fin factor, thermal diffusivity factor, and inductance factor. These new device factors allow for the straight-forward description of phenomenon generally only captured with numerical work otherwise. As an example a device design factor of 0.38, which accounts for thermal resistance of the hot and cold shoes, can be used to calculate a conversion efficiency of 2.28 while the ideal conversion efficiency based on figure of merit alone would be 6.15. Likewise an ideal couple with efficiency of 6.15 will be reduced to 5.33 when lateral heat is accounted for with a fin factor of 1.0.

Seebeck effect↗

Methods and Devices for Micro-Isolation, Extraction, and/or Analysis of Microscale Components

Provided herein are devices and methods for the micro-isolation of biological cellular material. A micro-isolation apparatus described can comprise a photomask that protects regions of interest against DNA-destroying illumination. The micro-isolation apparatus can further comprise photosensitive material defining access wells following illumination and subsequent developing of the photosensitive material. The micro-isolation apparatus can further comprise a chambered microfluidic device comprising channels providing access to wells defined in photosensitive material. The micro-isolation apparatus can comprise a chambered microfluidic device without access wells defined in photosensitive material where valves control the flow of gases or liquids through the channels of the microfluidic device. Also included are methods for selectively isolating cellular material using the apparatuses described herein, as are methods for biochemical analysis of individual regions of interest of cellular material using the devices described herein. Further included are methods of making masking arrays useful for the methods described herein.

Kartalov, Emil P.↗

Biomechanical Modeling of the Deadlift Exercise on the HULK Device to Improve the Efficacy of Resistive Exercise Microgravity Countermeasures

Extended spaceflight typically results in the loss of muscular strength and bone density due to exposure to microgravity. Resistive exercise countermeasures have been developed to maintain musculoskeletal health during spaceflight. The Advanced Resistive Exercise Device (ARED) is the "gold standard" of available devices; however, its footprint and volume are too large for use in space capsules employed in exploration missions. The Hybrid Ultimate Lifting Kit (HULK) device, with its smaller footprint, is a prototype exercise device for exploration missions. This work models the deadlift exercise being performed on the HULK device using biomechanical simulation, with the long-term goal to improve and optimize astronauts' exercise prescriptions, to maximize the benefit of exercise while minimizing time and effort invested.

Countermeasures↗

Insertion Loss of a Multi-Plane Light Conversion Device with Few Mode Fiber Outputs Under Atmospheric Conditions

A key challenge of photon counting optical communication is delivering light with atmospherically distorted wavefronts from the telescope to detectors efficiently. When using fiber coupled single photon detectors, the efficiency of the transmittance is constrained by the modes supported by the fiber. The number of modes supported by a fiber depends on the size of the core. The larger the core, the more modes supported. However, commercial off the shelf superconducting nanowire single photon detectors (SNSPDs) are currently limited in area, which limits the core size of the fibers that can efficiently couple to the detectors. To increase the amount of light that can be delivered to the detectors, NASA Glenn Research Center is considering many different fiber/detector architectures. This paper compares insertion loss of the fiber device for two different architectures: • a multi-plane light conversion device to split the light from a 30 µm core diameter fiber into 7 separate, 15 µm core diameter few-mode fibers butt-coupled to 7 single-element SNSPDs, and • a 30 µm core diameter multimode fiber butt-coupled to a 16 multi-element, SNSPD array. The measured insertion loss for each fiber device under emulated atmospheric conditions with D/r0 between 2 and 30 is presented. The multi-plane light conversion device shows a consistent ~1 dB loss more than the multimode fiber. Also presented is the measured uneven power splitting of the multiplane light conversion device, especially at lower D/r0. How this uneven power splitting contributes to system loss called blocking loss is discussed.

Fiber↗

Food Sanitation Device for Use in Microgravity

EDEN is a transportation/orbital habitat that carries large amounts of crew members, food, and supplies from Earth to Mars and back, but can also act as a permanent, simulated-1g-environment space station in Martian orbit. The focus of the project is to create a temporary, but long-term living environment that focuses on human health and food production. The project is composed of four major habitable parts (in addition to other major components). Moving from the center out, the first is a central core that acts as a hub that connects to the structural spokes, the main propulsion rockets and serves as a place for other spacecraft to dock onto, in addition to housing some of the basic station control, navigation and automated computer systems. The second set of parts are the spokes that connect the ring to the central core; these are the primary structural components with elevators in the middle carrying people from the ring to the core. The ‘lower’ portions, near the ring and it’s 1g environment, also act as storage centers. The third part is the 2-story outer ring This project served as an engineering senior design project at Temple University, and as part of NASA’s eXploration and Habitation (X-Hab) 2018 Academic Innovation Challenge. The goal of the project was to design, construct, and test a device which would be used in microgravity to sanitize produce. This is part of a NASA’s effort to grow and sanitize fresh produce on the International Space Station (ISS), in order to provide more nutritious meal options to the astronauts. Our team designed a 3-D printed spherical device with UV-C LEDs lining the interior. The designed device consists of an 8” spherical chamber, 10 UV-C LEDs, and a touchscreen user interface to control the device. Our design meets the project requirements by offering several features: a simple user interface, minimal crew time to operate, no waste produced, and the ability to sanitize multiple types of produce. The main reductions in Salmonella bacteria and Aspergillus Flavus mold were not verified. However, the aerobic plate count requirement was greatly exceeded and validated. Testing of the device resulted in visual results confirming significant decrease in E. coli activity with increased UV-C exposure, as well as quantitative results confirming significant reduction in CFU/g for the aerobic plate count. These reductions achieved from 1.464 x 10 7 to 2 x 10 4 CFU/g (2.86 log reduction) after 5 minutes, were significantly more than the requirements given by NASA ( of the craft, which holds all of the food production along with medical bays, a control center and a few parks. This ring also integrates the rigid keystone modules, which are the interface between the spokes, the expandable-construction portions of the ring and the habitation pods. The keystone modules also incorporate redundant, distributed ECLSS systems, medical storage, airlocks, and other integral station functions. The last parts are the habitation pods; these hold the sleeping quarters along with the bathrooms, showers, kitchen space and lounge areas. These expandable modules latch onto the keystone modules of the ring, which serves as a circulatory link between the different habitation pods.

Damien Gordon↗

Organic light emitting devices for illumination

An organic light emitting device an a method of obtaining illumination from such a device is provided. The device has a plurality of regions, each region having an organic emissive layer adapted to emit a different spectrum of light. The regions in combination emit light suitable for illumination purposes. The area of each region may be selected such that the device is more efficient than an otherwise equivalent device having regions of equal size. The regions may have an aspect ratio of at least about four. All parts of any given region may be driven at the same current.

47 OTHER INSTRUMENTATION↗

Investigation of the Degradation Mechanisms of a Variety of Organic Photovoltaic Devices by Combination of Imaging Techniques—the ISOS-3Inter-laboratory Collaboration

The investigation of degradation of seven distinct sets (with a number of individual cells of n {ge} 12) of state of the art organic photovoltaic devices prepared by leading research laboratories with a combination of imaging methods is reported. All devices have been shipped to and degraded at Risoe DTU up to 1830 hours in accordance with established ISOS-3 protocols under defined illumination conditions. Imaging of device function at different stages of degradation was performed by laser-beam induced current (LBIC) scanning; luminescence imaging, specifically photoluminescence (PLI) and electroluminescence (ELI); as well as by lock-in thermography (LIT). Each of the imaging techniques exhibits its specific advantages with respect to sensing certain degradation features, which will be compared and discussed here in detail. As a consequence, a combination of several imaging techniques yields very conclusive information about the degradation processes controlling device function. The large variety of device architectures in turn enables valuable progress in the proper interpretation of imaging results - hence revealing the benefits of this large scale cooperation in making a step forward in the understanding of organic solar cell aging and its interpretation by state-of-the-art imaging methods.

14 SOLAR ENERGY↗

Liquid crystal device and method thereof

The invention provides a liquid crystal device and method thereof. Subsequent to applying a first electrical voltage on a liquid crystal to induce a reorientation of the liquid crystal, a second electrical voltage with proper polarity is applied on the liquid crystal to assist the relaxation of the reorientation that was induced by the first electrical voltage. The "switch-off" phase of the liquid crystal can therefore be accelerated or temporally shortened, and the device can exhibit better performance such as fast response to on/off signals. The invention can be widely used LCD, LC shutter, LC lens, spatial light modulator, telecommunication device, tunable filter, beam steering device, and electrically driven LC device, among others.

47 OTHER INSTRUMENTATION↗

Electrical device fabrication from nanotube formations

A method for forming nanotube electrical devices, arrays of nanotube electrical devices, and device structures and arrays of device structures formed by the methods. Various methods of the present invention allow creation of semiconducting and/or conducting devices from readily grown SWNT carpets rather than requiring the preparation of a patterned growth channel and takes advantage of the self-controlling nature of these carpet heights to ensure a known and controlled channel length for reliable electronic properties as compared to the prior methods.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Upconverting device for enhanced recogntion of certain wavelengths of light

An upconverting device for enhanced recognition of selected wavelengths is provided. The device comprises a transparent light transmitter in combination with a plurality of upconverting nanoparticles. The device may a lens in eyewear or alternatively a transparent panel such as a window in an instrument or machine. In use the upconverting device is positioned between a light source and the eye(s) of the user of the upconverting device.

47 OTHER INSTRUMENTATION↗

Encapsulation methods for organic electrical devices

The disclosure provides methods and materials suitable for use as encapsulation barriers in electronic devices. In one embodiment, for example, there is provided an electroluminescent device or other electronic device encapsulated by alternating layers of a silicon-containing bonding material and a ceramic material. The encapsulation methods provide, for example, electronic devices with increased stability and shelf-life. The invention is useful, for example, in the field of microelectronic devices.

36 MATERIALS SCIENCE↗

Encapsulation methods and dielectric layers for organic electrical devices

The disclosure provides methods and materials suitable for use as encapsulation barriers and dielectric layers in electronic devices. In one embodiment, for example, there is provided an electroluminescent device or other electronic device with a dielectric layer comprising alternating layers of a silicon-containing bonding material and a ceramic material. The methods provide, for example, electronic devices with increased stability and shelf-life. The invention is useful, for example, in the field of microelectronic devices.

36 MATERIALS SCIENCE↗