Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “detector response”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 865 records · Page 48

Mitigation and characterization of crosstalk between laser-driven radiography sources

Radiography with multiple probe species offers the potential to extract additional information about a given object as compared to radiography with a single probe species. Notably, the flexibility for high-power, short-pulse lasers to accelerate a variety of particle species makes laser-driven sources an attractive option to achieve multi-probe radiography. However, crosstalk produced by each of laser-driven source may be responsible for substantial backgrounds on detectors, becoming a significant barrier to achieving simultaneous radiography. In this work, we describe measurements of and mitigation strategies against crosstalk between laser-driven radiography sources in experiments at the OMEGA EP laser.

47 OTHER INSTRUMENTATION↗

RADAI: A Large-Scale Realistic Dataset for Radiation Detection Algorithm Development

Open, realistic datasets are essential for developing and benchmarking radiation detection algorithms, yet they remain scarce. The Radiological Anomaly Detection and Identification (RADAI) project was develop to create datasets that meet the training and testing needs for sophisticated radiation detection algorithms. The RADAI dataset is a large-scale synthetic resource that integrates high-fidelity Monte Carlo simulations with realistic urban scenarios to capture both background variability and source signatures. RADAI models construction-material NORM, people and vehicles, urban clutter, and dynamic environmental effects such as cosmic-ray and rain-induced transients, and they provide list-mode detector data with motion and response modeling suitable for algorithm training and evaluation. The RADAI project resulted in three publicly-released complementary datasets together with an online scoring portal for standardized performance assessment and an open software toolkit that supports data access, augmentation, model development, and evaluation. These resources enable reproducible comparisons across methods and promote rigorous studies at the scale required by contemporary machine learning. By grounding algorithm development in realistic, well-documented conditions, RADAI supports progress toward more robust detection, identification, and localization in complex urban environments.

Ghawaly, James M. [Division of Computer Science an↗

SAMPA Based Streaming Readout Data Acquisition Prototype

We have assembled a small-scale streaming data acquisition system based on the SAMPA front-end ASIC. The 32-channel SAMPA chip was designed for the high-luminosity upgrade of the ALICE Time Projection Chamber (TPC) detector at the CERN Large Hadron Collider. The goals of the prototype system are to determine if the SAMPA chip is appropriate for use in detector systems at Jefferson Lab, and to gain experience with the hardware and software required to deploy streaming data acquisition systems in nuclear physics experiments. The 800 channel system is composed of components used in the ALICE TPC data acquisition upgrade. Five front-end cards (FEC) support five SAMPA chips each. SAMPA data streams on an FEC are concentrated into two high-speed (4.48 Gb/s) serial data streams by a pair Gigabit Transceiver ASICs (GBTx). These ten streams (44.8 Gb/s) are transmitted from the FECs over fibers to a PCIe based readout unit. The FPGA engine on the readout unit compresses data for transmission to a server via 100 Gb ethernet. Components on the FECs are radiation tolerant. High data rates can be handled. The system is by design scalable and thus provides a functional prototype for high-rate streaming readout at Jefferson Lab and the future Electron Ion Collider. We have made fundamental measurements (noise, linearity, time resolution) on the SAMPA ASIC. We have also coupled the readout system to a small Gas Electron Multiplier (GEM) detector and have studied its response to cosmic rays. A beam test of the system is planned.

ABBOTT, David↗

BM3DORNL

BM3DORNL is a high-performance, open-source library for removing streak and ring artifacts from computed-tomography (CT) data, developed for neutron imaging at Oak Ridge National Laboratory's Spallation Neutron Source (VENUS beamline) and applicable to X-ray CT as well. Ring artifacts — concentric rings in reconstructed slices caused by detector pixel-to-pixel response non-uniformities — appear as vertical streaks in the sinogram and degrade both image quality and quantitative analysis. BM3DORNL operates in the sinogram domain using an adaptation of the BM3D (block-matching and 3D collaborative filtering) algorithm (Dabov et al., 2007). It provides a dedicated streak-removal mode, a true multi-scale BM3D variant (after Mäkinen et al., 2021) that suppresses wide streaks single-scale methods miss, and an alternative Fourier–SVD method (~2.6× faster) combining FFT-based energy detection with rank-1 SVD. The computationally intensive core is implemented in Rust with parallel (Rayon) block matching, integral-image pre-screening, and optimized transforms, and is exposed through a simple Python API (with an optional GUI) so it integrates directly into existing tomography reconstruction pipelines. It processes both 2D sinograms and 3D sinogram stacks, is pip-installable for Linux and macOS, and is documented at https://bm3dornl.readthedocs.io.

Zhang, Chen [Oak Ridge National Laboratory (ORNL),↗

Guidance and control research

Guidance and control research - Josephson junction memory elements, frequency response of thin film thermal detectors, gallium selenide barrier gate, and photoconductor metal contacts

Source record↗

The nuclear radiation monitor for the Spacelab/Shuttle

A 5 inch by 5 inch diameter sodium iodide scintillation crystal, viewed by a 5 inch photomultiplier was designed to be mounted near the center of the shuttle payload bay to quantitatively measure the neutron and gamma ray environment during the second Spacelab mission. The expected energy resolution is 8% FWHM at 662 keV. The detector will operate in an energy range from 0.1 to 20 MeV. A charged anticoincidence shield consisting of a 1 cm thick plastic scintillator viewed by three 2 inch photomultiplier tubes, covers the crystal detector which has nearly omnidirectional response.

Fishman, G. J.↗

Fundamentals of absolute pyroheliometry and objective characterization

The radiometric methodology in use with a narrow field of view radiometer for observation of the solar constant is described. The radiation output of the Sun is assumed to be constant, enabling the monitoring of the solar source by an accurately pointed radiometer, and the Sun's output is measured as a function of time. The instrument is described, its angular response considered, and principles for absolute radiometric measurement presented. Active modes of operation are analyzed, taking into consideration instrumental perturbations and sensor efficiency, heating wire effect, cavity sensor efficiency, thermal effects on the surface of the sensitive area, the effect of the field of view limiting system, and the frequency response of the heat flux detector and absolute radiometric system. Performance of absolute measurements with relatively high accuracy is demonstrated.

Crommelynck, D. A.↗

Time and energy dependence of the cosmic ray gradient in the outer heliosphere

Pioneers 10 and 11, now 35 and 18 AU from the Sun, continue to extend our knowledge of the spatial dependence of cosmic ray intensities in the heliosphere. Radial gradients measured from these spacecraft by UCSD detectors which have integral energy responses above thresholds of 80 and 500 MeV/nucleon are reported. An average gradient of 2%/AU typifies the data set as a whole, but there are time and energy dependences that deviate from this value. With operating lifetimes of 13 and 12 years, respectively, for the two spacecraft, the time dependence was followed for over a solar cycle. The higher energy channel shows less modulation on all time scales. At the start of the present cycle, the gradient is lower than the average value during the last solar cycle.

Fillius, W.↗

A redshift survey of IRAS galaxies. I - Sample selection

A complete all-sky sample of objects, flux-limited at 60 microns, has been extracted from the data base of the IRAS. The sample consists of 5014 objects, of which 2649 are galaxies and 13 are not yet identified. In order to study large-scale structure with this sample, it must be free of systematic biases. Corrections are applied for a major systematic effect in the flux densities listed in the IRAS Point Source Catalog: sources resolved by the IRAS beam have flux densities systematically underestimated. In addition, accurate flux densities are obtained for sources flagged as variable, or of moderate flux quality at 60 microns. The IRAS detectors suffered radiation-induced responsivity enhancement (hysteresis) due to crossings of the satellite scans across the Galactic plane; this effect is measured and is shown to be negligible.

Strauss, Michael A.↗

Model for the computation of self-motion in biological systems

A technique is presented by which direction- and speed-tuned cells, such as those commonly found in the middle temporal region of the primate brain, can be utilized to analyze the patterns of retinal image motion that are generated during observer movement through the environment. The developed model determines heading by finding the peak response in a population of detectors or neurons each tuned to a particular heading direction. It is suggested that a complex interaction of multiple cell networks is required for the solution of the self-motion problem in the primate brain.

Perrone, John A.↗

Characteristics of the HYDICE sensor

In 1992, in an effort to significantly improve knowledge in the field of hyperspectral imagery, the Naval Research Laboratories defined a set of requirements for a new generation sensor. Construction of this instrument, designated HYDICE, has recently been completed at Hughes Danbury Optical Systems. It is currently being flight tested on a Convair 580 operated by ERIM. This paper reports on some of the performance parameters measured to date. The majority of these are derived from laboratory test data. Optomechanical parameters include MTF, spatial co-registration, 'smile', spectral profile and spectral calibration. Detector-related parameters include system responsivity, signal to noise ratio, radiometric stability and gain linearity. The results are compared with the original system performance predictions.

Basedow, R. W.↗

Study of the Polarization Properties of the Crab Nebula and Pulsar with BATSE

Activities carried out under this proposal included: 1) development and refinements of Monte Carlo simulations of the atmospheric reflected albedo hard x-ray emissions, both unpolarized and polarized, 2) modeling and simulations of the off-axis response of the BATSE LAD detectors, and 3) comparison of our simulation results with numerous BATSE flare and cosmic burst data sets.

Forrest, David J.↗

Two-Step Calibration of a Multiwavelength Pyrometer for High Temperature Measurement Using a Quartz Lamp

There is no theoretical upper temperature limit for pyrometer application in temperature measurements. NASA Glenn's multiwavelength pyrometer can make measurements over wide temperature ranges. However, the radiation spectral response of the pyrometer's detector must be calibrated before any temperature measurement is attempted, and it is recommended that calibration be done at temperatures close to those for which measurements will be made. Calibration is a determination of the constants of proportionality at all wavelengths between the detector's output (voltage) and its input signals (usually from a blackbody radiation source) in order to convert detector output into radiation intensity. To measure high temperatures, the detectors are chosen to be sensitive in the spectral range from 0.4 to 2.5 micrometers. A blackbody furnace equilibrated at around 1000 C is often used for this calibration. Though the detector may respond sensitively to short wavelengths radiation, a blackbody furnace at 1000 C emits only feebly at very short wavelengths. As a consequence, the calibration constants that result may not be the most accurate. For pyrometry calibration, a radiation source emitting strongly at the short wavelengths is preferred. We have chosen a quartz halogen lamp for this purpose.

Ng, Daniel↗

Cosmic Ray Energetics and Mass (CREAM)

The CREAM instrument was flown on a Long Duration Balloon in Antarctica in December 2004 and January 2005, achieving a flight duration record of nearly 42 days. It detected and recorded cosmic ray primary particles ranging in type from hydrogen to iron nuclei and in energy from 1 TeV to several hundred TeV. With the data collected we will have the world's best measurement of the energy spectra and mass composition of nuclei in the primary cosmic ray flux at these energies, close to the astrophysical knee . The instrument utilized a thin calorimeter, a transition radiation detector and a timing charge detector, which also provided time-of-flight information. The responsibilities of our group have been with the timing charge detector (TCD), and with the data acquisition electronics and ground station support equipment. The TCD utilized fast scintillators to measure the charge of the primary cosmic ray before any interactions could take place within the calorimeter. The data acquisition electronics handled the output of the various detectors, in a fashion fully integrated with the payload bus. A space-qualified flight computer controlled the acquisition, and was used for preliminary trigger information processing and decision making. Ground support equipment was used to monitor the health of the payload, acquire and archive the data transmitted to the ground, and to provide real-time control of the instrument in flight.

Coutu, Stephane↗

Design of High Resolution Soft X-Ray Microcalorimeters Using Magnetic Penetration Thermometers

We have designed high-resolution soft x-ray microcalorimeters using magnetic penetration thermometers (MPTs) in an array of pixels covering a total of 2 square centimeters to have a resolving power of 300 at energies around 300 eV. This performance is desirable for studying the soft x-ray background from the warm hot intergalactic medium. MPT devices have small sensor heat capacity and high responsivities, which makes them excellent detector technology for attempting to attain sub-eV resolution. We are investigating the feasibility of pixels with absorbers that are 625 x 625 square micrometers, up to 1 x 1 square millimeters in area and 0.35 micrometer thick and thinner. Our tests have shown that suspended gold absorbers 0.35 micrometers thick (RRR = 6.7) are feasible to fabricate. We modeled the thermal diffusion from such thin gold over the size of a 625 x 625 square micrometer absorber, and conclude that the effect of the thermalization on the resolution of a 300 eV photon is an additional approximately 0.2 eV FWHM of broadening. We discuss the thermal effects of small absorber attachment sterns on solid substrate, as well as considerations for multiplexed readout. We will present the progress we have made towards building and testing this soft x-ray detector.

Busch. Sarah↗

Mission Oriented Support and Theory (MOST) for MMS -- The Goddard Space Flight Center/University of California Los Angeles Interdisciplinary Science Program

The MOST IDS team was tasked with focusing on two general areas: The first was to participate with the Fast Plasma Investigation (FPI) team in the development of virtual detectors that model the instrument responses of the MMS FPI sensors. The virtual instruments can be 'flown through' both simulation data (from magnetohydrodynamic, hybrid, and kinetic simulations) and Cluster and THEMIS spacecraft data. The goal is to determine signatures of magnetic reconnection expected during the MMS mission. Such signatures can serve as triggers for selection of burst mode downloads. The chapter contributed by the FPI team covers that effort in detail and, therefore, most of that work has not been included here. The second area of emphasis, and the one detailed in this chapter, was to build on past and present knowledge of magnetic reconnection and its physical signatures. Below we describe intensive analyses of Cluster and THEMIS data together with theoretical models and simulations that delineate the plasma signatures that surround sites of reconnection, including the effects of turbulence as well as the detailed kinetic signatures that indicate proximity to reconnection sites. In particular, we point out that particles are energized in several regions, not only at the actual site of reconnection.

Goldstein, Melvyn L.↗

Laser Spiderweb Sensor Used with Portable Handheld Devices

A portable spectrometer, including a smart phone case storing a portable spectrometer, wherein the portable spectrometer includes a cavity; a source for emitting electromagnetic radiation that is directed on a sample in the cavity, wherein the electromagnetic radiation is reflected within the cavity to form multiple passes of the electromagnetic radiation through the sample; a detector for detecting the electromagnetic radiation after the electromagnetic radiation has made the multiple passes through the sample in the cavity, the detector outputting a signal in response to the detecting; and a device for communicating the signal to a smart phone, wherein the smart phone executes an application that performs a spectral analysis of the signal.

Scott, David C.↗