Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “data intensive computing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 865 records · Page 48

WE-AB-207A-06: Progressive Dose Control for Cone Beam CT with Deformation Assisted Temporal Nonlocal Means Method

Purpose: To reduce cone beam CT (CBCT) imaging dose, we previously proposed a progressive dose control (PDC) scheme to employ temporal correlation between CBCT images at different fractions for image quality enhancement. A temporal non-local means (TNLM) method was developed to enhance quality of a new low-dose CBCT using existing high-quality CBCT. To enhance a voxel value, the TNLM method searches for similar voxels in a window. Due to patient deformation among the two CBCTs, a large searching window was required, reducing image quality and computational efficiency. This abstract proposes a deformation-assisted TNLM (DA-TNLM) method to solve this problem. Methods: For a low-dose CBCT to be enhanced using a high-quality CBCT, we first performed deformable image registration between the low-dose CBCT and the high-quality CBCT to approximately establish voxel correspondence between the two. A searching window for a voxel was then set based on the deformation vector field. Specifically, the search window for each voxel was shifted by the deformation vector. A TNLM step was then applied using only voxels within this determined window to correct image intensity at the low-dose CBCT. Results: We have tested the proposed scheme on simulated CIRS phantom data and real patient data. The CITS phantom was scanned on Varian onboard imaging CBCT system with coach shifting and dose reducing for each time. The real patient data was acquired in four fractions with dose reduced from standard CBCT dose to 12.5% of standard dose. It was found that the DA-TNLM method can reduce total dose by over 75% on average in the first four fractions. Conclusion: We have developed a PDC scheme which can enhance the quality of image scanned at low dose using a DA-TNLM method. Tests in phantom and patient studies demonstrated promising results.

60 APPLIED LIFE SCIENCES↗

Optimization of Scrap Melting Using an Electric Arc in Steel Manufacturing

Steel industry is crucial to the national economy and security. Around 67% of crude steel in the U.S is produced in electric arc furnaces (EAF), which is energy intensive. Around 140 EAFs operate in the U.S., consuming about 8.6x10 7 MMBtu/year of electricity. One of major challenges for EAFs includes maximizing the efficiency of the electrical energy provided in the form of electric arcs to melt various scrap mixes. To address this issue, a computational fluid dynamics (CFD) methodology is chosen to analyze scrap melting using the electric arc. Due to complex furnace phenomena and the wide variety of potential scenarios, high performance computing (HPC) is essential to yield comprehensive and detailed CFD analyses and systematic parametric studies for optimized EAF operation. The objectives are to 1) simulate scrap melting using electric arc, 2) evaluate electrode/arc position for optimum scrap melting and 3) establish reduced order model for CFD data-base for fast model calculation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Introduction of a novel ultrahigh sensitivity collimator for brain SPECT imaging

Purpose: Noise levels of brain SPECT images are highest in central regions, due to preferential attenuation of photons emitted from deep structures. To address this problem, the authors have designed a novel collimator for brain SPECT imaging that yields greatly increased sensitivity near the center of the brain without loss of resolution. This hybrid collimator consisted of ultrashort cone-beam holes in the central regions and slant-holes in the periphery (USCB). We evaluated this collimator for quantitative brain imaging tasks. Methods: Owing to the uniqueness of the USCB collimation, the hole pattern required substantial variations in collimator parameters. To utilize the lead-casting technique, the authors designed two supporting plates to position about 37 000 hexagonal, slightly tapered pins. The holes in the supporting plates were modeled to yield the desired focal length, hole length, and septal thickness. To determine the properties of the manufactured collimator and to compute the system matrix, the authors prepared an array of point sources that covered the entire detector area. Each point source contained 32 μCi of Tc-99m at the first scan time. The array was imaged for 5 min at each of the 64 shifted locations to yield a 2-mm sampling distance, and hole parameters were calculated. The sensitivity was also measured using a point source placed along the central ray at several distances from the collimator face. High-count projection data from a five-compartment brain phantom were acquired with the three collimators on a dual-head SPECT/CT system. The authors calculated Cramer-Rao bounds on the precision of estimates of striatal and background activity concentration. In order to assess the new collimation system to detect changes in striatal activity, the authors evaluated the precision of measuring a 5% decrease in right putamen activity. The authors also reconstructed images of projection data obtained by summing data from the individual phantom compartments. Results: The sensitivity of the novel cone-beam collimator varied with distance from the detector face; it was higher than that of the fan-beam collimator by factors ranging from 2.7 to 162. Examination of the projections of the point sources revealed that only a few holes were distorted or partially blocked, indicating that the intensive manual fabrication process was very successful. Better reconstructed phantom images were obtained from the USCB+FAN collimator pair than from either LEHR or FAN collimation. For the left caudate, located near the center of the brain, the detected counts were 9.8 (8.3) times higher for UCSB compared with LEHR (FAN), averaged over 60 views. The task-specific SNR for detecting a 5% decrease in putamen uptake was 7.4 for USCB and 3.2 for LEHR. Conclusions: The authors have designed and manufactured a novel collimator for brain SPECT imaging. The sensitivity is much higher than that of a fan-beam collimator. Because of differences between the manufactured collimator and its design, reconstruction of the data requires a measured system matrix. The authors have demonstrated the potential of USCB collimation for improved precision in estimating striatal uptake. The novel collimator may be useful for early detection of Parkinson’s disease, and for monitoring therapy response and disease progression.

60 APPLIED LIFE SCIENCES↗

Using multimodal X-ray computed tomography to advance 3D petrography: A non-destructive investigation of olivine inside a carbonaceous chondrite

Rocks form in three dimensions through time and studying them provides information from inside dynamic systems we cannot otherwise observe. Yet how we typically access the interior of the rocks themselves to gain that information may limit our understanding and influence how we reconstruct the processes that formed them. Here, we demonstrate combined non-destructive 3D X-ray imaging techniques that produce quantitative densitometric and crystallographic maps of entire individual grains inside a rock. Olivine grains throughout a sample of the carbonaceous chondrite Northwest Africa (NWA) 11346 were each characterized by size, shape, composition, zoning intensity, and crystallographic orientation. The addition of 3D crystallographic mapping to calibrated 3D densitometric analysis—used to calculate chemical composition—demonstrates a fully non-destructive petrographic method and provides unique insight. For instance, in our case, using crystallographic data to delineate individual grains and then measuring the 3D size, shape, and composition of each distinguishes variably reset relict grains from those later crystallized after a melting event. Intersection in a 2D slice could not have led to this interpretation because the integration of three-dimensional size, rounding, composition, location, and crystallographic orientation measured from each grain forms the key patterns. Multimodal laboratory X-ray imaging has strong potential to advance 3D petrography.

36 MATERIALS SCIENCE↗

A hybrid CNN-LSTM surrogate model for hyper-resolution spatiotemporal flood forecasting in Norfolk, Virginia

Study region: Norfolk, Virginia, United States Study focus: Accurate and timely flood forecasting is essential for enhancing resilience in coastal urban areas in the context of increasing frequency and intensity of rainfall, sea level rise and urbanization. This study presents a hybrid deep learning-based surrogate model that integrates Convolutional Neural Networks (CNN) and Long Short-Term Memory (LSTM) networks to enable real-time spatiotemporal flood forecasting. The model leverages CNN to capture spatial features from inputs such as elevation and Topographic Wetness Index (TWI), while LSTM processes time-series inputs of rainfall and tide data to capture temporal features. New hydrologic insights for the region: The hybrid CNN-LSTM model was trained using the physics-based hydrodynamic model simulations obtained from the Two-dimensional Unsteady FLOW (TUFLOW) model for Norfolk, Virginia, and achieved high predictive accuracy across diverse flood-prone areas. The reduced computational time from four to six hours using TUFLOW to 3.2 min per event using CNN-LSTM enables rapid flood inundation mapping and early warning applications. The model effectively captured both spatial flood extents and their temporal evolution across different flooding scenarios, providing forecasts at a 2.5-m spatial resolution and 15-min temporal resolution and a one-hour-ahead prediction horizon. While challenges remain in terms of transferability to new regions and real-time data assimilation, this approach demonstrates strong potential for supporting operational flood risk management in coastal urban environments.

Coastal urban flooding↗

SU-E-I-05: A Correction Algorithm for Kilovoltage Cone-Beam Computed Tomography Dose Calculations in Cervical Cancer Patients

Purpose: To investigate the accuracy and feasibility of dose calculations using kilovoltage cone beam computed tomography in cervical cancer radiotherapy using a correction algorithm. Methods: The Hounsfield units (HU) and electron density (HU-density) curve was obtained for both planning CT (pCT) and kilovoltage cone beam CT (CBCT) using a CIRS-062 calibration phantom. The pCT and kV-CBCT images have different HU values, and if the HU-density curve of CBCT was directly used to calculate dose in CBCT images may have a deviation on dose distribution. It is necessary to normalize the different HU values between pCT and CBCT. A HU correction algorithm was used for CBCT images (cCBCT). Fifteen intensity-modulated radiation therapy (IMRT) plans of cervical cancer were chosen, and the plans were transferred to the pCT and cCBCT data sets without any changes for dose calculations. Phantom and patient studies were carried out. The dose differences and dose distributions were compared between cCBCT plan and pCT plan. Results: The HU number of CBCT was measured by several times, and the maximum change was less than 2%. To compare with pCT, the CBCT and cCBCT has a discrepancy, the dose differences in CBCT and cCBCT images were 2.48%±0.65% (range: 1.3%∼3.8%) and 0.48%±0.21% (range: 0.1%∼0.82%) for phantom study, respectively. For dose calculation in patient images, the dose differences were 2.25%±0.43% (range: 1.4%∼3.4%) and 0.63%±0.35% (range: 0.13%∼0.97%), respectively. And for the dose distributions, the passing rate of cCBCT was higher than the CBCTs. Conclusion: The CBCT image for dose calculation is feasible in cervical cancer radiotherapy, and the correction algorithm offers acceptable accuracy. It will become a useful tool for adaptive radiation therapy.

60 APPLIED LIFE SCIENCES↗

Precision QCD, Hadronic Structure & Forward QCD, Heavy Ions: Report of Energy Frontier Topical Groups 5, 6, 7 submitted to Snowmass 2021

This report was prepared on behalf of three Energy Frontier Topical Groups of the Snowmass 2021 Community Planning Exercise. It summarizes the status and implications of studies of strong interactions in high-energy experiments and QCD theory. We emphasize the rich landscape and broad impact of these studies in the decade ahead. Hadronic interactions play a central role in the high-luminosity Large Hadron Collider (LHC) physics program, and strong synergies exist between the (HL-)LHC and planned or proposed experiments at the U.S. Electron-Ion Collider, CERN forward physics experiments, high-intensity facilities, and future TeV-range lepton and hadron colliders. Prospects for precision determinations of the strong coupling and a variety of nonperturbative distribution and fragmentation functions are examined. We also review the potential of envisioned tests of new dynamical regimes of QCD in high-energy and high-density scattering processes with nucleon, ion, and photon initial states. The important role of the high-energy heavy-ion program in studies of nuclear structure and the nuclear medium, and its connections with QCD involving nucleons are summarized. We address ongoing and future theoretical advancements in multi-loop QCD computations, lattice QCD, jet substructure, and event generators. Cross-cutting connections between experimental measurements, theoretical predictions, large-scale data analysis, and high-performance computing are emphasized.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Modern Radiation Therapy for Hodgkin Lymphoma: Field and Dose Guidelines From the International Lymphoma Radiation Oncology Group (ILROG)

Radiation therapy (RT) is the most effective single modality for local control of Hodgkin lymphoma (HL) and an important component of therapy for many patients. These guidelines have been developed to address the use of RT in HL in the modern era of combined modality treatment. The role of reduced volumes and doses is addressed, integrating modern imaging with 3-dimensional (3D) planning and advanced techniques of treatment delivery. The previously applied extended field (EF) and original involved field (IF) techniques, which treated larger volumes based on nodal stations, have now been replaced by the use of limited volumes, based solely on detectable nodal (and extranodal extension) involvement at presentation, using contrast-enhanced computed tomography, positron emission tomography/computed tomography, magnetic resonance imaging, or a combination of these techniques. The International Commission on Radiation Units and Measurements concepts of gross tumor volume, clinical target volume, internal target volume, and planning target volume are used for defining the targeted volumes. Newer treatment techniques, including intensity modulated radiation therapy, breath-hold, image guided radiation therapy, and 4-dimensional imaging, should be implemented when their use is expected to decrease significantly the risk for normal tissue damage while still achieving the primary goal of local tumor control. The highly conformal involved node radiation therapy (INRT), recently introduced for patients for whom optimal imaging is available, is explained. A new concept, involved site radiation therapy (ISRT), is introduced as the standard conformal therapy for the scenario, commonly encountered, wherein optimal imaging is not available. There is increasing evidence that RT doses used in the past are higher than necessary for disease control in this era of combined modality therapy. The use of INRT and of lower doses in early-stage HL is supported by available data. Although the use of ISRT has not yet been validated in a formal study, it is more conservative than INRT, accounting for suboptimal information and appropriately designed for safe local disease control. The goal of modern smaller field radiation therapy is to reduce both treatment volume and treatment dose while maintaining efficacy and minimizing acute and late sequelae. This review is a consensus of the International Lymphoma Radiation Oncology Group (ILROG) Steering Committee regarding the modern approach to RT in the treatment of HL, outlining a new concept of ISRT in which reduced treatment volumes are planned for the effective control of involved sites of HL. Nodal and extranodal non-Hodgkin lymphomas (NHL) are covered separately by ILROG guidelines.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-T-125: Dosimetric Comparison of Intensity Modulated Radiation Therapy Using Robotic Versus Traditional Linac Platform in Prostate Cancer

Purpose: Recent development of an MLC for robotic external beam radiotherapy has the potential of new clinical application in conventionally fractionated radiation therapy. This study offers a dosimetric comparison of IMRT plans using Cyberknife with MLC versus conventional linac plans. Methods: Ten prostate cancer patients treated on a traditional linac with IMRT to 7920cGy at 180cGy/fraction were randomly selected. GTVs were defined as prostate plus proximal seminal vesicles. PTVs were defined as GTV+8mm in all directions except 5mm posteriorly. Conventional IMRT planning was performed on Philips Pinnacle and delivered on a standard linac with CBCT and 10mm collimator leaf width. For each case a Cyberknife plan was created using Accuray Multiplan with same CT data set, contours, and dose constraints. All dosimetric data was transferred to third party software for independent computation of contour volumes and DVH. Delivery efficiency was evaluated using total MU, treatment time, number of beams, and number of segments. Results: Evaluation criteria including percent target coverage, homogeneity index, and conformity index were found to be comparable. All dose constraints from QUANTEC were found to be statistically similar except rectum V50Gy and bladder V65Gy. Average rectum V50Gy was lower for robotic IMRT (30.07%±6.57) versus traditional (34.73%±3.62, p=0.0130). Average bladder V65Gy was lower for robotic (17.87%±12.74) versus traditional (21.03%±11.93, p=0.0405). Linac plans utilized 9 coplanar beams, 48.9±3.8 segments, and 19381±2399MU. Robotic plans utilized 38.4±9.0 non-coplanar beams, 85.5±21.0 segments and 42554.71±16381.54 MU. The average treatment was 15.02±0.60 minutes for traditional versus 20.90±2.51 for robotic. Conclusion: The robotic IMRT plans were comparable to the traditional IMRT plans in meeting the target volume dose objectives. Critical structure dose constraints were largely comparable although statistically significant differences were found in favor of the robotic platform in terms of rectum V50Gy and bladder V65Gy at a cost of 25% longer treatment time.

60 APPLIED LIFE SCIENCES↗

Design of the radiation shielding for the time of flight enhanced diagnostics neutron spectrometer at Experimental Advanced Superconducting Tokamak

A radiation shielding has been designed to reduce scattered neutrons and background gamma-rays for the new double-ring Time Of Flight Enhanced Diagnostics (TOFED). The shielding was designed based on simulation with the Monte Carlo code MCNP5. Dedicated model of the EAST tokamak has been developed together with the emission neutron source profile and spectrum; the latter were simulated with the Nubeam and GENESIS codes. Significant reduction of background radiation at the detector can be achieved and this satisfies the requirement of TOFED. The intensities of the scattered and direct neutrons in the line of sight of the TOFED neutron spectrometer at EAST are studied for future data interpretation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A spectroscopic, structural, and computational study of Ag–oxo interactions in Ag + /UO 2 2+ complexes

For this work, twelve novel Ag + /UO 2 2+ heterometallic complexes have been prepared and characterized via structural, spectroscopic, and computational methods to probe the effects of Ag–oxo interactions on bonding and photophysical properties of the uranyl cation. Structural characterization reveals Ag–oxo interaction distances ranging from 2.475(3) Å to 4.287(4) Å. These interactions were probed using luminescence and Raman spectroscopy which displayed little effect on the luminescence intensity and the energy of the Raman active U═O symmetric stretch peak as compared to previously reported Pb–oxo interactions. Computational efforts via density functional theory-based natural bond orbital analysis revealed that the highest stabilization energy associated with the Ag–oxo interaction had a value of only 11.03 kcal mol –1 and that all other energy values fell at 7.05 kcal mol –1 or below indicating weaker interactions relative to those previously reported for Pb 2+ /UO 2 2+ heterometallic compounds. In contrast, quantum theory of atoms in molecules analysis of bond critical point electron density values indicated higher electron density in Ag–oxo interactions as compared to Pb–oxo interactions which suggests more covalent character with the Ag + . Overall, this data indicates that Ag + has a less significant effect on UO 2 2+ bonding and photophysical properties as compared to other Pb 2+ , likely due to the high polarizability of the cation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Patch-based generation of a pseudo CT from conventional MRI sequences for MRI-only radiotherapy of the brain

Purpose: In radiotherapy (RT) based on magnetic resonance imaging (MRI) as the only modality, the information on electron density must be derived from the MRI scan by creating a so-called pseudo computed tomography (pCT). This is a nontrivial task, since the voxel-intensities in an MRI scan are not uniquely related to electron density. To solve the task, voxel-based or atlas-based models have typically been used. The voxel-based models require a specialized dual ultrashort echo time MRI sequence for bone visualization and the atlas-based models require deformable registrations of conventional MRI scans. In this study, we investigate the potential of a patch-based method for creating a pCT based on conventional T{sub 1}-weighted MRI scans without using deformable registrations. We compare this method against two state-of-the-art methods within the voxel-based and atlas-based categories. Methods: The data consisted of CT and MRI scans of five cranial RT patients. To compare the performance of the different methods, a nested cross validation was done to find optimal model parameters for all the methods. Voxel-wise and geometric evaluations of the pCTs were done. Furthermore, a radiologic evaluation based on water equivalent path lengths was carried out, comparing the upper hemisphere of the head in the pCT and the real CT. Finally, the dosimetric accuracy was tested and compared for a photon treatment plan. Results: The pCTs produced with the patch-based method had the best voxel-wise, geometric, and radiologic agreement with the real CT, closely followed by the atlas-based method. In terms of the dosimetric accuracy, the patch-based method had average deviations of less than 0.5% in measures related to target coverage. Conclusions: We showed that a patch-based method could generate an accurate pCT based on conventional T{sub 1}-weighted MRI sequences and without deformable registrations. In our evaluations, the method performed better than existing voxel-based and atlas-based methods and showed a promising potential for RT of the brain based only on MRI.

60 APPLIED LIFE SCIENCES↗

Bayesian Abel Inversion in Quantitative X-Ray Radiography

A common image formation process in high-energy X-ray radiography is to have a pulsed power source that emits X-rays through a scene, a scintillator that absorbs X-rays and uoresces in the visible spectrum in response to the absorbed photons, and a CCD camera that images the visible light emitted from the scintillator. The intensity image is related to areal density, and, for an object that is radially symmetric about a central axis, the Abel transform then gives the object's volumetric density. Two of the primary drawbacks to classical variational methods for Abel inversion are their sensitivity to the type and scale of regularization chosen and the lack of natural methods for quantifying the uncertainties associated with the reconstructions. In this work we cast the Abel inversion problem within a statistical framework in order to compute volumetric object densities from X-ray radiographs and to quantify uncertainties in the reconstruction. A hierarchical Bayesian model is developed with a likelihood based on a Gaussian noise model and with priors placed on the unknown density pro le, the data precision matrix, and two scale parameters. This allows the data to drive the localization of features in the reconstruction and results in a joint posterior distribution for the unknown density pro le, the prior parameters, and the spatial structure of the precision matrix. Results of the density reconstructions and pointwise uncertainty estimates are presented for both synthetic signals and real data from a U.S. Department of Energy X-ray imaging facility.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Review, evaluation, and discussion of the challenges of missing value imputation for mass spectrometry-based label-free global proteomics

In this review, we apply selected imputation strategies to label-free liquid chromatography–mass spectrometry (LC–MS) proteomics datasets to evaluate the accuracy with respect to metrics of variance and classification. We evaluate several commonly used imputation approaches for individual merits and discuss the caveats of each approach with respect to the example LC–MS proteomics data. In general, local similarity-based approaches, such as the regularized expectation maximization and least-squares adaptive algorithms, yield the best overall performances with respect to metrics of accuracy and robustness. However, no single algorithm consistently outperforms the remaining approaches, and in some cases, performing classification without imputation sometimes yielded the most accurate classification. Thus, because of the complex mechanisms of missing data in proteomics, which also vary from peptide to protein, no individual method is a single solution for imputation. In summary, on the basis of the observations in this review, the goal for imputation in the field of computational proteomics should be to develop new approaches that work generically for this data type and new strategies to guide users in the selection of the best imputation for their dataset and analysis objectives.

59 BASIC BIOLOGICAL SCIENCES↗

New method for analysis of X-ray computed tomography scans of TRISO fuel forms

X-ray computed tomography (XCT) is a powerful characterization tool that has been used for examination of both tristructural-isotropic (TRISO) coated particles and fuel forms. Rapid, nondestructive imaging of complete specimens by XCT provides significant characterization advantages in both speed and comprehensiveness over traditional materialographic methods. This paper discusses a method that has been developed to analyze XCT images of pebble fuel forms containing ~18,000 TRISO particles each. The XCT images are three-dimensional with contrast based on relative x-ray transparency. In the case of TRISO fuel forms, XCT image intensity distinguishes between the high-density kernel, the medium-density SiC, and the low-density matrix and carbon layers. Image analysis software has been developed to process XCT data sets to extract spatial distribution information, including particle nearest-neighbor distances, local packing fraction, and fuel-free zone thickness in TRISO fuel forms. Finally, although this type of high-resolution XCT analysis is likely not feasible as a quality control measurement for commercial TRISO fuel, it is highly useful in generating feedback for the development of fuel form fabrication processes.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Applying an improved rapid impact assessment matrix method to strategic environmental assessment of urban planning in China

Strategic environmental assessment (SEA) has become an increasingly important decision-support tool for providing information on the environmental implications of a policy, plan, or program. The goal is to safeguard the environment and promote sustainable development at the strategic level. Despite major progress in implementing SEA practices internationally, developing countries, such as China, often lag behind in applying SEA methodology. Lack of available data and time constraints arising from tight schedules create problems. The rapid impact assessment matrix (RIAM) is a potential resource for breaking through such difficulties. Our analysis of RIAM applications suggested that it could become a tool for evaluating strategic alternatives because of its applicability in interdisciplinary settings, its transparency, and its short implementation timeframe. To make it more suitable for the SEA context, we have developed two major improvements to the conventional RIAM process: assignment of weights to assessment indicators and the development of an integrated environmental assessment score (IES). The improved RIAM process was employed in an SEA of the development plan for the Nansha District in Guangzhou, the capital city of Guangdong Province in China. It was used to assess five alternatives for development in Wanqingsha (WQS), a subunit of Nansha, where important ecological resources are located and where industrial development could impact the air quality in the neighboring Hong Kong Special Administrative Region (HKSAR). The evaluation identified WQS-A04 as the preferred alternative. This alternative involved a minimal amount of industrial development – 10% compared with the most intense development alternative – and included important wetland preservation plans. The assessment results have been incorporated into the officially approved development plan for Nansha. The improved RIAM methodology is well adapted to the technical aims of SEA and decision-making structures in China. It offers the potential for delivering timely and quality results to decision-making processes. To achieve the desired efficiency, it is recommended that an SEA procedure take into account findings acquired from an improved RIAM application at an early stage, then, at a later stage, results from more comprehensive assessments conducted using more sophisticated methods should be added, if time and data are available. - Highlights: • RIAM is a potential SEA tool due to its multidisciplinary setting and rapid process. • Weighting index and computing IES are raised for improving RIAM when applied to SEAs. • The improved RIAM boosts SEA effectiveness by timely responding to decision-making. • The improved RIAM is more suitable to an SEA bothered by tight time or data shortage. • The improved RIAM adapts to the technical aims of SEA and decision features in China.

54 ENVIRONMENTAL SCIENCES↗

Defining the “Hostile Pelvis” for Intensity Modulated Radiation Therapy: The Impact of Anatomic Variations in Pelvic Dimensions on Dose Delivered to Target Volumes and Organs at Risk in Patients With High-Risk Prostate Cancer Treated With Whole Pelvic Radiation Therapy

Purpose: The aim of this study was to evaluate the impact of variations in pelvic dimensions on the dose delivered to the target volumes and the organs at risk (OARs) in patients with high-risk prostate cancer (PCa) to be treated with whole pelvic radiation therapy (WPRT) in an attempt to define the hostile pelvis in terms of intensity modulated radiation therapy (IMRT). Methods and Materials: In 45 men with high-risk PCa to be treated with WPRT, the target volumes and the OARs were delineated, the dose constraints for the OARs were defined, and treatment plans were generated according to the Radiation Therapy Oncology Group 0924 protocol. Six dimensions to reflect the depth, width, and height of the bony pelvis were measured, and 2 indexes were calculated from the planning computed tomographic scans. The minimum dose (D{sub min}), maximum dose (D{sub max}), and mean dose (D{sub mean}) for the target volumes and OARs and the partial volumes of each of these structures receiving a specified dose (V{sub D}) were calculated from the dose-volume histograms (DVHs). The data from the DVHs were correlated with the pelvic dimensions and indexes. Results: According to an overall hostility score (OHS) calculation, 25 patients were grouped as having a hospitable pelvis and 20 as having a hostile pelvis. Regarding the OHS grouping, the DVHs for the bladder, bowel bag, left femoral head, and right femoral head differed in favor of the hospitable pelvis group, and the DVHs for the rectum differed for a range of lower doses in favor of the hospitable pelvis group. Conclusions: Pelvimetry might be used as a guide to define the challenging anatomy or the hostile pelvis in terms of treatment planning for IMRT in patients with high-risk PCa to be treated with WPRT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Deep learning-driven super-resolution in Raman hyperspectral imaging: Efficient high-resolution reconstruction from low-resolution data

Deep learning (DL) has become an indispensable tool in hyperspectral data analysis, automatically extracting valuable features from complex, high-dimensional datasets. Super-resolution reconstruction, an essential aspect of hyperspectral data, involves enhancing spatial resolution, particularly relevant to low-resolution hyperspectral data. Yet, the pursuit of super-resolution in hyperspectral analysis is fraught with challenges, including acquiring ground truth high-resolution data for training, generalization, and scalability. The pressing issue of extended spectral acquisition times, notably for high-resolution scans, is a significant roadblock in hyperspectral imaging. Super-resolution methods offer a promising solution by providing higher spatial resolution data to expedite data collection and yield more efficient outcomes. This paper delves into a practical application of these concepts using Raman imaging, where spectral acquisition times can be prohibitively long. In this context, DL-based super-resolution models demonstrate their efficacy by predicting and reconstructing high-resolution Raman data from low-resolution input, eliminating the need for resource-intensive high-resolution scans. While previous work often relied on substantial high-resolution datasets, this study showcases the ability to achieve similar outcomes even with limited data, presenting a more practical and cost-effective approach. In conclusion, the results offer a glimpse into the transformative potential of this technology to streamline hyperspectral imaging applications by saving valuable time and resources through the successful generation of high-resolution data from low-resolution inputs.

42 ENGINEERING↗