Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “cooling load”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 865 records · Page 48

Validation Gap Assessment of a MAP Package Containing Fresh, Metallic Sodium-Cooled Fuel

This report describes an assessment of sodium fast reactor assemblies loaded within an AREVA MAP package. The assessment was performed to determine the state of the validation basis for sodium fast reactor fuel within a transportation package originally intended for fresh, light-water reactor fuel assemblies. A similar study is being simultaneously released (Cumberland, 2025), and substantial parts of the explanatory text are identical to that parallel work, which follows the same workflow. Both studies employed the TSUNAMI-3D and TSUNAMI-IP sequences from the SCALE code system to determine correlation coefficients between various configurations and databases of validation assessments.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Validation Gap Assessment of a TN B1 Package Containing Fresh, Metallic Sodium-Cooled Fuel

This report describes an assessment of sodium fast reactor assemblies loaded inside a Transnuclear B1 package. The assessment was performed to determine the state of the validation basis for sodium fast reactor fuel within a transportation package originally intended for fresh, light-water reactor fuel assemblies. The study employed the TSUNAMI-3D and TSUNAMI-IP sequences from the SCALE code system to determine correlation coefficients between various configurations and databases of validation assessments.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Evaluation of load tracks and wear of two sets of bearings from space shuttle main engine high pressure oxygen turbopumps

Bearings supporting the rotor in the High Pressure Oxygen Turbopump (HPOTP) were examined. The No. 1 bearings from both units were in good condition and had successfully completed 5000 seconds of operation. The No. 2 bearings, which were in service the same length of time, were significantly degraded in the form of ball wear, race pitting, and damage from high axial loads. The No. 3 and 4 bearings were in generally acceptable condition. The general conclusion from the examinations was that improved cooling on the No. 2 bearings and further improvements in controlling axial and radial load would likely result in the HPOTP meeting the qualification test results.

Kannel, J. W.↗

Thermal Design and Analysis of a Multi-Stage 30K Radiative Cooling System for EPIC

The Experimental Probe of Inflationary Cosmology (EPIC) is an implementation of the NASA Einstein Inflation Probe mission, to answer questions about the physics of Inflation in the early Universe by measuring the polarization of the Cosmic Microwave Background (CMB). The mission relies on a passive cooling system to cool the enclosure of a telescope to 30 K; a cryocooler then cools this enclosure to 18 K and the telescope to 4 K. Subsequently, an adiabatic demagnetization refrigerator further cools a large focal plane to approx.100 mK. For this mission, the telescope has an aperture of 1.4 m, and the spacecraft's symmetry axis is oriented approx. 45 degrees relative to the direction of the sun. The spacecraft will be spun at approx. 0.5 rpm around this axis, which then precesses on the sky at 1 rph. The passive system must both supply the necessary cooling power for the cryocooler and meet demanding temperature stability requirements. We describe the thermal design of a passive cooling system consisting of four V-groove radiators for shielding of solar radiation and cooling the telescope to 30 K. The design realizes loads of 20 and 68 mW at the 4 K and 18 K stages on the cooler, respectively. A lower cost option for reaching 40 K with three V-groove radiators is also described. The analysis includes radiation coupling between stages of the radiators and sunshields, and parasitic conduction in the bipod support, harnesses, and ADR leads. Dynamic effects are also estimated, including the very small variations in temperature due to the scan motion of the spacecraft.

Space↗

Theoretical Limits of Vapor Cooling Large Cylindrical Structures Using Boil-Off

The Structural Heat Intercept, Insulation, and Vibration Evaluation Rig (SHIIVER) is planning to demonstrate the performance benefits of using boil-off to reduce the heat load on various upper stage structural members by using the boil-off vapor to intercept some of the heat load on the structures. A first order simplified analytical model was constructed in order to understand sensitivity of various parameters to performance as well as to understand the theoretical maximum performance of the vapor cooling of a thin-walled cylindrical structure. Constant fluid properties and a temperature dependent thermal conductivity of the structure material were assumed. The model showed that vapor cooling of an aluminum cylindrical structure with hydrogen can reduce the heat load along the cylinder by as much as 70%. Also, cooling a portion of the cylinder is quite effective in comparison with cooling it entirely.

R. Balasubramaniam↗

Key Residential Building Equipment Technologies for Control and Grid Support PART I (Residential)

Electrical energy consumption of the residential sector is a crucial area of research that has in the past primarily focused on increasing the efficiency of household devices such as water heaters, dishwashers, air conditioners, and clothes washer and dryer units. However, the focus of this research is shifting as objectives such as developing the smart grid and ensuring that the power system remains reliable come to the fore, along with the increasing need to reduce energy use and costs. Load research has started to focus on mechanisms to support the power system through demand reduction and/or reliability services. The power system relies on matching generation and load, and day-ahead and real-time energy markets capture most of this need. However, a separate set of grid services exist to address the discrepancies in load and generation arising from contingencies and operational mismatches, and to ensure that the transmission system is available for delivery of power from generation to load. Currently, these grid services are mostly provided by generation resources. The addition of renewable resources with their inherent variability can complicate the issue of power system reliability and lead to the increased need for grid services. Using load as a resource, through demand response programs, can fill the additional need for flexible resources and even reduce costly energy peaks. Loads have been shown to have response that is equal to or better than generation in some cases. Furthermore, price-incentivized demand response programs have been shown to reduce the peak energy requirements, thereby affecting the wholesale market efficiency and overall energy prices. The residential sector is not only the largest consumer of electrical energy in the United States, but also has the highest potential to provide demand reduction and power system support, as technological advancements in load control, sensor technologies, and communication are made. The prevailing loads based on the largest electrical energy consumers in the residential sector are space heating and cooling, washer and dryer, water heating, lighting, computers and electronics, dishwasher and range, and refrigeration. As the largest loads, these loads provide the highest potential for delivering demand response and reliability services. Many residential loads have inherent flexibility that is related to the purpose of the load. Depending on the load type, electric power consumption levels can either be ramped, changed in a step-change fashion, or completely removed. Loads with only on-off capability (such as clothes washers and dryers) provide less flexibility than resources that can be ramped or step-changed. Add-on devices may be able to provide extra demand response capabilities. Still, operating residential loads effectively requires awareness of the delicate balance of occupants health and comfort and electrical energy consumption. This report is Phase I of a series of reports aimed at identifying gaps in automated home energy management systems for incorporation of building appliances, vehicles, and renewable adoption into a smart grid, specifically with the intent of examining demand response and load factor control for power system support. The objective is to capture existing gaps in load control, energy management systems, and sensor technology with consideration of PHEV and renewable technologies to establish areas of research for the Department of Energy. In this report, (1) data is collected and examined from state of the art homes to characterize the primary residential loads as well as PHEVs and photovoltaic for potential adoption into energy management control strategies; and (2) demand response rules and requirements across the various demand response programs are examined for potential participation of residential loads. This report will be followed by a Phase II report aimed at identifying the current state of technology of energy management systems, sensors, and communication technologies for demand response and load factor control applications for the residential sector. The purpose is to cover the gaps that exist in the information captured by the sensors for energy management system to be able to provide demand response and load factor control. The vision is the development of an energy management system or other controlling enterprise hardware and software that is not only able to control loads, PHEVs, and renewable generation for demand response and load factor control, but also to do so with consumer comforts in mind and in an optimal fashion.

24 POWER TRANSMISSION AND DISTRIBUTION↗

On the possible cycles via the unified perspective of cryocoolers. Part A: The Joule-Thomson cryocooler

Joule-Thomson (JT) cryocoolers possess a self adjusting effect, which preserves the state of the returning stream from the evaporator as a saturated vapor. The heat load can be entirely absorbed at constant temperature by evaporation even for different sized heat exchangers. It is not possible for the steady state flow resulting from a gradual cool down to penetrate 'deeper' into the two-phase dome, and produce a two phase return flow even with a heat exchanger of unlimited size. Such behavior was implicitly taken for granted in the literature but never clearly stated nor questioned and therefore never systematically proven. The discussion provided below provides such a proof via the unified model of cryocoolers. This model portrays all cryocoolers as magnifiers of their respective elementary temperature reducing mechanism through the process of 'interchanging'.

42 ENGINEERING↗

Effectiveness of street trees in reducing air temperature and outdoor heat exposure in Las Vegas

Urban greening and especially tree planting strategies are being widely planned and implemented to mitigate urban overheating and thermal stress in many urban areas. However, the effectiveness of these strategies depends on multiple factors, including urban morphology, environmental conditions, and tree characteristics. This study investigates the effects of street tree planting strategies on air temperature and outdoor heat exposure in Las Vegas by combining an urbanized mesoscale climate model coupled to a multi-layer street tree model (Weather Research and Forecasting-BEP-Tree; Δ x = 900 m) with a microscale pedestrian heat exposure model (Temperatures of Urban Facets for Pedestrian; Δ x = 1 m). A series of simulations are conducted for July and August 2022. Large city-wide increases of a drought tolerant tree species cool air temperature mainly during the nighttime (up to 1.5 °C), with daytime effects being limited due to leaves shedding sensible instead of latent heat as stomata close in response to high vapor pressure deficits. Increased evaporative cooling is achieved with a different tree species (double at night, and reaching 0.4 °C during the day), but water requirements increase threefold. Despite their relatively small effect on air temperature during the day, trees provide significant shade by intercepting solar radiation, reducing mean radiant temperature (up to 16 °C) and enhancing outdoor thermal comfort, a major benefit of street trees in hot arid climates. The nighttime cooling of trees and the daytime reduction of radiant loading show potential to reduce the heat-related health impacts. Our results highlight the need to evaluate the effects of street trees on a case-by-case basis.

54 ENVIRONMENTAL SCIENCES↗

An Analysis of Simulated and Observed Global Mean Near-Surface Air Temperature Anomalies from 1979 to 1999: Trends and Attribution of Causes

The 1979 - 1999 response of the climate system to variations in solar spectral irradiance is estimated by comparing the global averaged surface temperature anomalies simulated by a 2D (two dimensional) energy balance climate model to observed temperature anomalies. We perform a multiple regression of southern oscillation index and the individual model responses to solar irradiance variations, stratospheric and tropospheric aerosol loading, stratospheric ozone trends, and greenhouse gases onto each of five near-surface temperature anomaly data sets. We estimate the observed difference in global mean near surface air temperature attributable to the solar irradiance difference between solar maximum and solar minimum to be between 0.06 and 0.11 K, and that 1.1 - 3.8% of the total variance in monthly mean near-surface air temperature data is attributable to nations in solar spectral irradiance. For the five temperature data sets used in our analysis, the trends in raw monthly mean temperature anomaly data have a large range, spanning a factor of 3 from 0.06 to 0.17 K/decade. However. our analysis suggests that trends in monthly temperature anomalies attributable to the combination of greenhouse gas, stratospheric ozone, and tropospheric sulfate aerosol variations are much more consistent among data sets, ranging from 0.16 to 0.24 K/decade. Our model results suggest that roughly half of the warming from greenhouse gases is cancelled by the cooling from changes in stratospheric ozone. Tropospheric sulfate aerosol loading in the present day atmospheric contributes significantly to the net radiative forcing of the present day climate system. However, because the change in magnitude and latitudinal distribution of tropospheric sulfate aerosol has been small over the past 20 years, the change in the direct radiative forcing attributable to changes in aerosol loading over this time is also small.

MacKay, R. M.↗

Subcontracted activities related to TES for building heating and cooling

The subcontract program elements related to thermal energy storage for building heating and cooling systems are outlined. The following factors are included: subcontracts in the utility load management application area; life and stability testing of packaged low cost energy storage materials; and development of thermal energy storage systems for residential space cooling. Resistance storage heater component development, demonstration of storage heater systems for residential applications, and simulation and evaluation of latent heat thermal energy storage (heat pump systems) are also discussed. Application of thermal energy storage for solar application and twin cities district heating are covered including an application analysis and technology assessment of thermal energy storage.

Martin, J.↗

Cooling for SC devices of test cryomodule for ADS Injector II at IMP

The superconducting half-wave resonance cavities connected in series with superconducting solenoids will be applied to the Injector II of the Accelerator Driven Sub-critical System (ADS) to be built at the Modern Physics Institute, China. A test system has been developed for the purpose of performance test of the HWR cavities as well as validating the relevant technique for cooling the cavity and the solenoids together. It mainly comprises a cryogenic valve box (TVB), a test cryomodule (TCM1) and transfer lines. The TCM1 includes one HWR cavity, two superconducting solenoids, one cold BPM and their cooling system. The design of the TCM1 cryostat was carried out by the Shanghai Institute of Applied Physics (SINAP), CAS. Both the cavity and the solenoids will work at 4.4 K by bath cooling. The fast cooling down for the cavity from around 100 K to 120 K is required to avoid degrading of the cavity performance. After cool down and before energization, the solenoids should be warmed up to above 10 K and re-cooled down for the purpose of degaussing. The TCM1 can not only be cooled by using the dewar-filling system, but also operated by the refrigerator system. For the purpose of reducing the heat loads to the cold mass at 4 K from room temperature, thermal radiation shields cooled by liquid nitrogen flowing in tubing were employed. This paper presents the design details of cooling circuits and thermal shields of the TCM1 as well as related calculations and analyses.

43 PARTICLE ACCELERATORS↗

A Preliminary Study of a Novel Heat Pump Integrated Underground Thermal Energy Storage for Shaping Electric Demand of Buildings

A Dual-Purpose Underground Thermal Battery (DPUTB) innovatively integrates a ground heat exchanger with underground thermal energy storage. The DPUTB can be integrated with an Electric-Driven Heat Pump (EDHP) to enable more flexible electric load for meeting the thermal demands of a building (e.g., space cooling and space heating). A one-dimensional numerical model of the DPUTB is developed and validated against measured performance data of a small-scale DPUTB prototype. The validated DPUTB model is integrated with a heat pump model and a building energy simulation model to predict the load shifting performance and energy consumption of an integrated EDHP and DPUTB system. Preliminary simulation results indicate that the integrated system can flatten the electric load profile of a typical residential building and reduce the electric demand during peak hours by 37% on a typical summer day. In addition, the integrated EDHP and DPUTB system also reduces the daily power consumption of the building by 11% compared with a conventional residential space heating and cooling system.

Liu, Xiaobing↗

PERFORMANCE EVALUATION OF CEILING RADIANT COOLING SYSTEM IN COMPOSITE CLIMATE

Radiant cooling systems are proving to be an energy efficient solution due to higher thermal capacity of cooling fluid especially for the buildings that require individual zone controls and where the latent loads are moderate. The Conventional air conditioners work at very low temperature i.e.5-8 c (refrigerant evaporator inlet) while the radiant cooling systems, also referred as high temperature cooling system, work at high temperatures i.e. 14-18 c. The radiant cooling systems can maintain lower MRT (Mean Radiant Temperature) as ceiling panels maintain uniform temperature gradient inside room and provide higher human comfort. The radiant cooling systems are relatively new systems and their operation and energy savings potential are not quantified for a large number of buildings and operational parameters. Moreover, there are only limited numbers of whole building simulation studies have been carried out for these systems to have a full confidence in the capability of modelling tools to simulate these systems and predict the impact of various operating parameters. Theoretically, savings achieve due to higher temperature set point of chilled water, which reduces chiller-running time. However, conventional air conditioner runs continuously to maintain requisite temperature. In this paper, experimental study for performance evaluation of radiant cooling system carried out on system installed at Malaviya National Institute of Technology Jaipur. This paper quantifies the energy savings opportunities and effective temperature by radiant cooling system at different chilled water flow rates and temperature range. The data collected/ analysed through experimental study will used for calibration and validation of system model of building prepared in building performance simulation software. This validated model used for exploring optimized combinations of key parameters for composite climate. These optimized combinations will used in formulation of radiant cooling system operations control strategy.

Ceiling Panels↗

Packed Bed thermal storage for compact Light water-cooled Small Modular Reactors

Nuclear power plants (NPPs) have less flexibility to follow grid load demand than their natural-gas fueled counterparts. Most of the natural-gas power plants can supply peak-loads by adding more fuel, and thus, can generate far more revenue during those peak hours. On the other hand, use of NPPs for peak load following is quite complex due to technical constraints associated with reactor behavior. These technical challenges include the adequate handling of reactivity swings caused by time-varying fuel and moderator temperatures, a higher fuel-failure probability due to thermal-structural cycling, and spatial variations in xenon concentration. Although there are presently some reactors around the world that are operating with flexible load-following capabilities, such operation is restricted to slowly-varying powers, 2-3 times a day, and only up to 80% of the fuel cycle. Thus, a more convenient and effective method to facilitate load following by NPPs would be to integrate energy storage Authors have previously developed models and performed exergy analysis for integrating liquid type TES with LWRs and SMRs. These exergy based models show that technical feasibility index of integrating thermal energy storage is very high. But most of these previous studies include integration based on existing layout of NPPs with heat exchange between storage Heat Transfer Fluid (HTF) and Reactor Coolant (RC). However, most of the Light Water-cooled Small modular reactor (LW-SMR) based NPP designs can not accommodate additional heat exchange equipment. Although power production is only reduced to 1/20 scale, the containment volume in thus NuScale LW-SMR is reduced to {approx} 1/170 scale. As steam is the secondary or working fluid which exits out of the reactor containment in LW-SMRs, the simplest and most practical way to integrate thermal storage with LW-SMRs is to directly store the energy from steam. Indirect heat exchange between steam and another heat transfer fluid during the storage process, and then heat recovery again via indirect heat exchange is inefficient process due to heat transfer resistance. This inefficiency is due to what is called as 'Pinch point' which occurs whenever there is indirect heat transfer between two media where one undergoes phase change and other undergoes change in sensible heat. Another existing popular option is to use a steam accumulator which stores dry or wet steam directly inside the pressure vessels, however, due to large volumetric requirements it is not a viable option. This work proposes a new method of integrating packed bed TES systems with LW-SMRs, where steam produced in the secondary side of LW-SMRs can be injected into the packed bed of inert particles with sufficient thermal conductivity and capacity to efficiently store energy with high energy density. The changes in the load demand will not effect the LWSMR operation and the excess steam will be diverted to TES. When the demand increases this stored energy in hot packed beds can be recovered by injecting cold pressurized water. Although there are some existing packed bed TES designs and models which consider steam as HTFs, these models have not been extended for wide range of process parameters important for this integration. Authors have previously developed a packed bed thermal model for steam injection and validated it using experimental data. This thermal model is extended to assess behavior of packed bed thermal energy storage (TES) system under storage and recovery cycles. Steam is the only heat transfer fluid (HTF) which exits the reactor vessel, so any application such as process heat or TES integration should be evaluated with steam as process fluid. This project will develop a process system integration model of LW-SMR with packed bed type TES using steam as HTF. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Load Flexibility Analysis of Residential HVAC and Water Heating and Commercial Refrigeration

The emergence of connected devices and the Internet of Things has opened the door to the concept of widespread use of building equipment for load-side flexibility. This stems from the increased use of distributed and clean energy resources for electric generation and the growing demand for a more resilient and reliable grid. A significant challenge associated with the use of building equipment as a distributed energy resource is quantifying the magnitude of power or energy flexibility. Unlike batteries that have well-defined and relatively constant capacity and maximum charge/discharge rates, building equipment often has characteristics that vary based on external factors (e.g., weather or occupant behavior). This makes quantifying the availability and flexibility of these resources difficult. Controlling a fleet of equipment while minimizing any adverse impacts to the occupants (e.g., discomfort or food spoilage) is a nontrivial matter. Although there are many different control methodologies available, this study focuses on two: priority-based control (PBC) and model-predictive control (MPC). These were selected because they represent two ends of the control spectrum. PBC is a relatively simple control strategy that requires only the current state of the devices to be controlled and an estimate of how much power each device consumes when turned on. MPC is much more complex and requires a model of the system and forecasts of any disturbances that influence the system. Because MPC has a predictive element, it can prepare for a desired response before the event and therefore is expected to provide a more optimal control relative to PBC. Both MPC and PBC are compared with a baseline simulation that uses feedback control typical of the thermostatically controlled devices being evaluated. This report investigates the load flexibility of three building systems: residential air conditioners, residential water heaters, and commercial refrigeration. Air heating and cooling and water heating account for 45% of residential electricity use, making them good candidates for providing load flexibility. Refrigeration in commercial buildings accounts for 16% of commercial building electricity use, making it another good candidate. Simplified models of each system were generated and validated based on measured data from actual equipment. These models were used to simulate the thermal and power response of the systems using PBC and MPC for a fleet of devices trying to achieve a variety of different responses, including hourly load shed, hourly load up, and daily peak demand reduction. Significant findings from each piece of equipment follow.

42 ENGINEERING↗

HYPERACCRETING BLACK HOLE AS GAMMA-RAY BURST CENTRAL ENGINE. I. BARYON LOADING IN GAMMA-RAY BURST JETS

A hyperaccreting stellar-mass black hole has been long speculated as the best candidate for the central engine of gamma-ray bursts (GRBs). Recent rich observations of GRBs by space missions such as Swift and Fermi pose new constraints on GRB central engine models. In this paper, we study the baryon-loading processes of a GRB jet launched from a black hole central engine. We consider a relativistic jet powered by {nu} {nu}-bar -annihilation or by the Blandford-Znajek (BZ) mechanism. We consider baryon loading from a neutrino-driven wind launched from a neutrino-cooling-dominated accretion flow. For a magnetically dominated BZ jet, we consider neutron drifting from the magnetic wall surrounding the jet and subsequent positron capture and proton-neutron inelastic collisions. The minimum baryon loads in both types of jet are calculated. We find that in both cases a more luminous jet tends to be more baryon poor. A neutrino-driven ''fireball'' is typically ''dirtier'' than a magnetically dominated jet, while a magnetically dominated jet can be much cleaner. Both models have the right scaling to interpret the empirical {Gamma}-L{sub iso} relation discovered recently. Since some neutrino-driven jets have too much baryon loading as compared with the data, we suggest that at least a good fraction of GRBs should have a magnetically dominated central engine.

79 ASTRONOMY AND ASTROPHYSICS↗

QUOKKA-based understanding of outflows (QED) – III. Outflow loading and phase structure as a function of galactic environment

ABSTRACT We present results from a suite of 3D high-resolution hydrodynamic simulations of supernova-driven outflows from galactic disc regions with a range of gas surface density, metallicity, and supernova scale height. We use this suite to quantify how outflow properties – particularly the loading factors for mass, metallicity, and energy – vary with these parameters. We find that the winds fall into three broad categories: steady and hot, multiphase and moderately bursty, and cool and highly bursty. The first of these is characterized by efficient metal and energy loading but weak mass loading, the second by moderate loading of mass, metals, and energy, and the third by negligible metal and energy loading but substantial mass loading. The most important factor in determining the kind of wind a galaxy will produce is the ratio of supernova to gas scale heights, with the latter set by a combination of supernova rate, metallicity-dependent cooling rate, and the gravitational potential. These often combine in counterintuitive ways – for example increased cooling causes cold clouds to sink into the galactic midplane more rapidly, lowering the volume-filling factor of dense gas and making the environment more favourable for strong winds. Our findings suggest that the nature of galactic winds is likely highly sensitive to phenomena such as runaway stars occurring at a large height and dense gas and are poorly captured in most simulations, and that metal loading factors for type Ia supernovae may be substantially larger than those for type II, with important implications for galactic chemical evolution.

Vijayan, Aditi (ORCID:0000000277142379)↗

Reviewing Spent Nuclear Fuel Dry Cask Storage Programs to Identify Challenges for an Integrated Waste Management System - 17535

Under the Nuclear Waste Policy Act (NWPA), the U.S. Department of Energy (DOE) has responsibility for removing commercial spent nuclear fuel (SNF) from nuclear power plant sites and disposing of the SNF in a deep geologic repository. However, the methods used by commercial nuclear power plants for onsite storage of their SNF define the starting conditions for DOE efforts to develop a waste management system that includes packaging, transportation, storage, and disposal of commercial SNF. The NWPA (as amended) also charges the U.S. Nuclear Waste Technical Review Board (Board) with evaluating the technical and scientific validity of DOE activities related to the management and disposal of SNF and high-level radioactive wastes (HLW). DOE's efforts related to developing an integrated program for storing, transporting, and disposing of SNF and HLW were the focus of a public meeting held by the Board on August 24, 2016, in Washington, D.C. To prepare for the public meeting, the Board's staff compiled information on the dry cask storage systems in service at nuclear power plant sites in order to identify issues that would need to be addressed by DOE in planning to transport SNF away from the sites. This paper is based on a briefing presented to the Board members by the Board's staff before the public meeting. Post-meeting findings and recommendations of the Nuclear Waste Technical Review Board are documented in the Board letter to the Department of Energy dated December 8, 2016. A note about terminology: in this paper, the phrase 'dry cask storage system' is generic and applies to a complete system used for dry storage of commercial SNF.Within these storage systems, commercial SNF is sealed inside a container called either a cask or a canister depending upon the specific type of storage system used. This distinction is discussed in more detail in the body of this paper. When referring to the containers holding SNF in particular systems, this paper uses the terms 'casks' or 'canisters,' as appropriate. When discussing the collective group of all containers, this paper uses the phrase 'casks and canisters'. Dry cask storage of SNF is a widespread practice throughout the U.S. commercial nuclear industry. As of August 1, 2016, more than 2300 storage casks and canisters were loaded at U.S. commercial nuclear power plant sites. This number is expected to increase by more than 200 casks and canisters annually, reaching a total of approximately 4500 by 2025. Multiple vendors have developed their own unique designs of dry cask storage and transportation systems. The majority of storage system designs (75 percent) feature SNF loaded in welded stainless steel canisters that are stored in ventilated concrete overpacks that allow for convection cooling. Some older dry cask storage system designs do not include a welded stainless steel canister; instead, SNF is loaded directly into a heavily shielded metal cask to minimize radiation exposure to workers and prevent atmospheric release of radionuclides. These types of systems are sealed by O-rings compressed under a bolted lid. After loading, dry cask storage systems are located on concrete pads at Independent Spent Fuel Storage Installations (ISFSI) at nuclear power plant sites and will remain there until the time when they will be transported to a consolidated interim storage facility or a deep geologic repository. Eventual transportation of canistered SNF will include removing the stainless steel canisters from the concrete overpacks, possibly repackaging the SNF, and loading the canisters into specially designed transportation casks for shipment by truck, rail, or barge. In the case of the non-canistered casks, some are approved for transportation and can be shipped after impact limiters are installed on the casks. SNF will need to be removed from casks not approved for transportation and transferred to transport-approved casks. This paper highlights five issues and challenges presented by the nuclear industry's use of dry cask storage systems that will need to be addressed by DOE in developing an integrated waste management system. One example, among the five, is that several dry-storage casks and canisters have received Nuclear Regulatory Commission certificates of compliance for storage only and do not have certificates of compliance for transportation. This will pose a challenge when the SNF must be moved to a consolidated interim storage facility or a deep geologic repository. Another example is that, when loaded with SNF, the total weight of new, larger transportation cask designs will exceed 142 metric tonnes (156 tons) which, when combined with the weight of the rail-car, will exceed the gross weight limit for unrestricted operation on some rail lines. This will also affect future transportation planning for shipments of SNF. All five issues and challenges are discussed in detail in the body of the paper. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗